You are on page 1of 23

APPENDIX

PRODUCT REFERENCES


HK AURORA/PSY LIGHTING

SPECIFICATION

Company Name

Product Name 75W


Part No 075-H

For customer fill
Confirmed department
Confirmed result
Signature

(Approve) (Auditing) (Make)











Features :
1. Astheworld'sfirstnewproducts,LEDbigbulbcoulddisplacethecompactTraditionalCFLlight.
2. Uniquestructure,wideangled(360),WiderangeofIrradiatedArea.
3. Smartheatdispersionstructure(patentdesign).
4. Offerthewellmixedfacular,withouttheshadowresult,longoperatinglifeandlowlumensdepreciation.
5. Variouslampholderareavailable,awiderangeofapplications.(E39/E40,E26/E27)
6. WidevoltageAC85265V.
7. UsingFansforbettercooling
8. UsingFanprotectioncircuit,whenfanscouldnotwork,thepowerofwholelampwillbereduced50%to
ensurethesafetyofthelamps.
9. MeettheCEstandard

Product Appearance :

Dimensions











MAIN SPECIFICATIONS (t=20)
PSY/AURORA-CORN LIGHT-075H
5730
7500LM
COLD WHITE, NATUAL ,WARM WHITE
>72
CIRCLE
<1%
>35000
AC 85 265
50/60 Hz
346
752W
0.95
<0.5 S
3750V
PC ALIMIUMM, PC
111.5*308mm
0.95
IP34
-25 4510% 90% R.H.
-40 850% 95% R.H.
CE
ROHS


Research Report:
















Fixing Ways:
UP OR DOWNSIDE


CORRECT WRONG

Packing

15
L W H Kg
Inner Box 120mm 120mm 340mm 1.0
Outer Box 615mm 255mm 360mm 11

2*510PCS










Applications :


BOTH INDOOR AND OUTDOOR WITH FULL PROTECTION



Issued November 2009 12498


DATA SHEET









C60 & C120
MCB



Based on Schneider Electric Catalogue
Protection
Circuit Breaker Limitation Capability
The limitation capability of a circuit breaker is that characteristic whereby
only a current less than the prospective fault current is allowed to flow under
short-circuit conditions.
This is illustrated by limitation curves which give:
" The limited peak current in relation to the
RMS value of the prospective short-circuit
current (the short-circuit current being that
current which would flow continuously in the
absence of protection equipment).
" The limited current stress in relation to the
RMS value of the prospective short-circuit
current.
" Current limiting capability. The advanced
design of the Multi-9 range provides current
limitation with far better protection than con-
ventional circuit breakers. For example, on a
6A rating with a prospective short circuit of
5000A, the current will be limited at 350A or
7%.
Installation of current limiting circuit breakers
offers several advantages:
# Better network protection
Current limiting circuit breakers considerably
reduce the undesirable effects of short-circuit
currents in an installation.
# Reduced thermal effects
Cable heating is reduced, hence longer cable
life.
# Reduced mechanical effects
Electrodynamic forces reduced, thus electri-
cal contacts are less likely to be deformed or
broken.
# Reduced electromagnetic effects
Measuring equipment situated near an elec-
trical circuit less affected.
Trip Unit Variations Circuit Breaker Marking
Curve B
tripping:
3 to 5 times the rated
current (In);
protection of generators,
persons, very long
cables.
Curve C
tripping:
5 to 10 In;
protection of circuits,
general applications.
Curve D
tripping:
10 to 14 In;
protection of high surge
circuits, welders, trans-
formers, motors.
Curve MA
(magnetic only)
tripping: 12 In;
protection of motor
starters (+ thermal pro-
tection when combined
with contactor).
Circuit Protection
A choice of several curves
Whatever circuit has to be pro-
tected, a C60 or C120 circuit
breaker provides the perfect
solution with a suitable curve.
1. Circuit Breaker Model Number
2. Tripping Curve
3. Circuit Breaker Current Rating
4. Operating Voltage
5. Rated Breaking Capacity
6. Circuit Breaker Part Number
7. Electrical Diagram - No. of Poles
8. I
2
t classification
Merlin Gerin Multi 9 System
Miniature circuit breakers
Tripping curves
Markings & limitation capability
1
2
3
4
5
8
C60H
C63
415V~
10000
3
2 ....
1
2
3
4
5
6
6 7
multi 9
12498
Based on Schneider Electric Catalogue Page 1 of 6
protection
circuit-breakers up to 63 A
C60a circuit-breakers
4.5 kA, C curve
AS/NZS 4898 Approval No: N13634
functions
description
technical data
C60a circuit-breakers
c power circuit
v voltage rating: 240 V AC
v number of cycles (O-C): 10 000
v foolproof terminal design
- moving barrier prevents incorrect cable
insertion
- cable strand centering guides ensure
correct cable positions and strand grouping
v isolation with positive contact indication
v bistable din clip, simplifies disassembly
c environment
v tropicalisation: treatment 2
(relative humidity: 95 % at 55 C)
v connection: tunnel terminals for the
following cables:
- up to 25A : 25mm
2
stranded
- 32 to 63A : 35mm
2
stranded
The circuit-breakers combine the following
functions:
- protection of circuits against short-circuit
currents,
- protection of circuits against overload
currents,
- control,
- protection of persons against indirect
contact.
- C60a circuit-breakers are used in the
domestic sectors where single phase fault
levels are less than or equal to 4.5kA.
C curve
utilisation
cables feeding conventional loads.
technical data
c power circuit
v tripping curves: the magnetic trip unit
operates between 5 and 10 In
v breaking capacity
- according to AS/NZS 4898 Icu ultimate
breaking capacity (0-C0 cycle):
type rating catalogue width quantity
(A) number in mod. per box
of 9 mm
C curve C60a
1P 6 11354 2 12
10 11355 2 12
16 11356 2 12
20 11357 2 12
25 11339 2 12
32 11358 2 12
40 11359 2 12
50 11360 2 12
63 11361 2 12
1
2
catalogue numbers
11357
- isolation,
rating voltage breaking
(A) (V) capacity
Icu (A)
1...63 240 4500
12498
Based on Schneider Electric Catalogue
Page 2 of 6
protection
circuit-breakers up to 63 A
C60N circuit-breakers
6kA, C curve
AS/NZS 4898 Approval No: N13634
functions
description
technical data common to
C60N circuit breakers
c power circuit
v voltage rating: 240/415 V AC
- for 2P single phase 240/480V
v I
2
t classification: 3
v number of cycles (O-C): 20 000
v foolproof terminal design
- moving barrier prevents incorrect cable
insertion
- cable strand centering guides ensure
correct cable positions and strand grouping
v isolation with positive contact indication
v bistable din clip, simplifies disassembly
c environment
v tropicalisation: treatment 2
(relative humidity: 95 % at 55 C)
v connection: tunnel terminals for the
following cables:
- up to 25A : 16mm
2
flexible with cable end
: 25mm
2
stranded
- 32 to 63A : 25mm
2
flexible with cable end
: 35mm
2
stranded
C curve
utilisation
cables feeding conventional loads.
technical data
c power circuit
v tripping curves: the magnetic trip units
operate between 5 and 10 In
v breaking capacity according to
AS/NZS 4898, Icu ultimate breaking capacity
(O-CO cycle):
rating type voltage breaking
capacity
(A) (V) Icu (A)
163 1P 240/415 6 000
2P 415...480 6 000
3P 415 6 000
The circuit-breakers combine the following
functions:
- protection of circuits against short-circuit
currents,
- protection of circuits against overload
currents,
- control,
- isolation,
- protection of persons against indirect
contact.
catalogue numbers type rating catalogue
(A) number
C curve C60N
1P 1 25797
2 25798
4 25800
6 25801
10 25802
16 25803
20 25804
25 25805
32 25806
40 25807
50 25808
63 25809
2P 1 25811
2 25812
4 25814
6 25815
10 25816
16 25817
20 25818
25 25819
32 25820
40 25821
50 25822
63 25823
3P 1 25825
2 25826
4 25828
6 25829
10 25830
16 25831
20 25832
25 25833
32 25834
40 25835
50 25836
63 25837
1
2
3
4
5
6
25804
1
2
1
2
3
4
25818
25832
Width in mod
of 9mm - 2
Width in mod
of 9mm - 4
Width in mod
of 9mm - 6
12498
Based on Schneider Electric Catalogue
Page 3 of 6
protection
circuit breakers up to 125A
C120N circuit-breakers
10kA, B, C curves - AS/NZS 4898
10kA, D curve AS 3947-2
function The circuit-breakers combine the following
functions:
- protection of circuits against short circuit
currents,
- protection of circuits against overload
currents,
- control,
Technical data common to C120N circuit
breakers
c power circuit
v current rating: 63 to 125 A
v voltage rating 415 V AC
v insulation voltage Ui: 500 V
v impulse withstand voltage Uimp: 6 kV
v breaking capacity:
- according to AS/NZS 4898 Icv ultimate
breaking capacity (O-CO cycle)
type voltage breaking cap.
(V) Icu (A)
1, 2, 3, 4P 240/415 10000
v according to AS3947-2 Icu ultimate
breaking capacity (O-CO cycle)
type voltage breaking cap.
(V) Icu (kA)
1P 240 10
415 3
2, 3, 4P 400415 10
v mechanical durability:
- 20000 cycles (O-C)
v electrical durability:
- 63 A: 10000 cycles (O-C)
- 80125 A: 5000 cycles (O-C)
v I
2
t classification: 3
v isolation with positive contact indication:
opening is indicated by a green strip on the
device operating handle. This indicator
shows opening of all the poles
v foolproof terminal design
- moving barrier prevents incorrect cable
insertion
- cable strand centering guides ensure
correct cable positions and strand grouping
v bistable din clip: simplifies disassembly
v 63 to 125A: - up to 35mm
2
flexible with
cable end
- up to 50mm
2
stranded
description
- isolation,
- protection of persons against indirect
contact.
B curve
utilisation
when there are small inrush currents
(generators, long cables).
technical data
c power circuit
v tripping curve:
the magnetic trip units operate between
3 and 5 In.
C curve
utilisation
cables feeding conventional loads.
technical data
c power circuit
v tripping curve:
the magnetic trip units operate between 5
and 10 In.
D curve - For industrial use only
utilisation
loads with a high inrush current
(motors, transformers).
technical data
c power circuit
v tripping curve:
the magnetic trip units operate between
10 and 14 In.
Approval No:Q00542
Approval No:Q00542
12498
Based on Schneider Electric Catalogue
Page 4 of 6
protection
circuit-breakers up to 125 A
C120N circuit-breakers
10kA, B, C curves - AS/NZS 4898
10kA, D curve AS 3947-2
18340
18344
1
2
3 1
4 2
catalogue numbers
18349
18355
5 3 1
6 4 2
7 5 3 1
8 6 4 2
type rating B C D
(A) Curve Curve Curve
B curve C120N
1P 63 18340 18356 18378
80 18341 18357 18379
100 18342 18358 18380
125 18343 18359 18381
2P 63 18344 18360 18382
80 18345 18361 18383
100 18346 18362 18384
125 18347 18363 18385
3P 63 18348 18364 18386
80 18349 18365 18387
100 18350 18367 18388
125 18351 18369 18389
4P 63 18352 18371 18390
80 18353 18372 18391
100 18354 18374 18392
1 25 18355 18377 18393
Width in mod
of 9mm - 3
Width in mod
of 9mm - 6
Width in mod
of 9mm - 9
Width in mod
of 9mm - 12
12498
Based on Schneider Electric Catalogue Page 5 of 6
Dimensions
C60a/N/H circuit breakers Vigi C60
C120N/H circuit breakers
C60/C120 auxiliaries
Vigi C120
27
54
81
81 45
44
73
16
5.5
5.5
6.5
7
3 4
7
max 3
max
21.2
84.3
108
2P
1P
3P
4P
OFF OFF OFF OFF
108
2P 2P
3P 3-4P
4P
81 90
87
18
45
44
63 54
95
73
16
5.5
OFF OFF OFF OFF
9 9 18 36
81
45
16 44
5.5 73
81
45
16 44
5.5 73
OF+SD/
OF
OF+SD/OF OF, SD
OF, S
MX
MN
MN s
36
81
OFF
36
12
81
OFF OFF OFF OFF
12
20
81
20
OFF OFF
C60 accessories
C120 accessories
12498
Based on Schneider Electric Catalogue
Page 6 of 6
T
h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
Jun 7, 2011
1
Product data sheet
Characteristics
A9R11463
iID 4P 63A 30mA AC-type
Main
Range of product IID
Device short name IID
Poles description 4P
Neutral position Left
Network type AC
Complementary
Device location in system Outgoer
[In] rated current 63 A
Network frequency 50/60 Hz
[Ue] rated operational voltage 400 V EN 61008-1 AC 50/60 Hz
400/415 V IEC 61008-1 AC 50/60 Hz
Residual current tripping technology Voltage independent
Earth-leakage sensitivity 30 mA
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Class AC
Rated breaking and making capacity 1500 A Idm
1500 A Im
Rated conditional short-circuit current 10 kA
Contact position indicator Yes
Control type Toggle
Local signalling Trip indicator
Mounting mode Removable comb busbar installed
Mounting support DIN rail
9 mm pitches 8
Width 72 mm
Connections - terminals Tunnel terminal with flap
Environment
Standards EN 61008-1
IEC 61008-1
RoHS EUR status Compliant
RoHS EUR conformity date 1001
3RH Contactor Relays
3RH2 contactor relays, 4- and 8-pole
3/58
SIRIUS Innovations Supplement 2011
3
IOverview
Contactor relays and coupling relays
Size S00 with accessories
Contactor relay
Coupling relay for auxiliary circuits
Solid-state timing relay block
1-pole auxiliary switch block, cable entry from above
2-pole auxiliary switch block, cable entry from above
1-pole auxiliary switch block, cable entry from below
2-pole auxiliary switch block, cable entry from below
4-pole auxiliary switch block
(terminal designations according to EN 50011 or EN 50005)
2-pole auxiliary switch block, solid-state compatible version
Terminal designations according to EN 50005
Solder pin adapter for contactor relays with 4-pole auxiliary switch block
Solder pin adapter for contactor relays and coupling relays
Additional load module for increasing the permissible residual current
Surge suppressor with LED
Surge suppressor without LED
3
4
5
6
7
8
9
10
11
14
12
13
1
2
10
11
11
N
S
B
0
_
0
2
0
5
8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Siemens AG 2011
3RH Contactor Relays
3RH2 contactor relays, 4- and 8-pole
3/59
SIRIUS Innovations Supplement 2011
3
AC and DC operation
IEC 60947, EN 60947.
The 3RH2 contactor relays have screw, ring lug terminal or
spring-type terminals. Four contacts are available in the basic
unit.
The 3RH2 contactor relays are suitable for use in any climate.
They are finger-safe according to EN 50274. The devices with
ring lug terminal connection comply with degree of protection
IP20 when fitted with the related terminal cover.
Contact reliability
High contact stability at low voltages and currents, suitable for
solid-state circuits with currents t 1 mA at a voltage of 17 V.
Surge suppression
RC elements, varistors, diodes or diode assemblies (combina-
tion of a diode and a Zener diode) can be plugged onto all con-
tactor relays from the front for damping opening surges in the
coil. The plug-in direction is determined by a coding device.
Note:
The OFF-delay of the NO contact and the ON-delay of the
NC contact are increased if the contactor coils are attenuated
against voltage peaks (noise suppression diode 6 to 10 times;
diode assemblies 2 to 6 times, varistor +2 to 5 ms).
Auxiliary switch blocks
The 3RH2 contactor relays can be expanded by up to four
contacts by the addition of snap-on auxiliary switch blocks.
The auxiliary switch block can easily be snapped onto the front
of the contactors. The auxiliary switch block has a centrally po-
sitioned release lever for disassembly.
The contactor relays with 4 contacts according to EN 50011,
with the identification number 40E, can be extended with 80E to
44E auxiliary switch blocks to obtain contactor relays with
8 contacts according to EN 50011. The identification numbers
80E to 44E on the auxiliary switch blocks apply to the complete
contactors. These auxiliary switch blocks (3RH29 111GA..)
cannot be combined with contactor relays with identification
numbers 31E and 22E; they are coded.
All contactor relays with 4 contacts according to EN 50011, iden-
tification numbers 40E to 22E, can be extended with auxiliary
switch blocks 40 to 02 to obtain contactor relays with 6 or 8 con-
tacts in accordance with EN 50005. The identification numbers
on the auxiliary switch blocks apply only to the attached auxiliary
switch blocks.
In addition, fully mounted 3RH22 8-pole contactor relays are
available; the mounted 4-pole auxiliary switch block in the 2nd
tier is not removable. The terminal designations are according to
EN 50011.
These versions are built according to special Swiss regulations
SUVA and are distinguished externally by a red labeling plate.
Of the auxiliary contacts (integrated plus mountable) possible
on the device, no more than four NC contacts are permitted.
Order No. scheme
Note:
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the
catalog in the Selection and ordering data.
Hilfsschtze
DIN EN50 005,
8 oder 6 Kontakte
N
S
B
0
_
0
2
1
0
5
Ident. No. 31E, 22E Ident. No. 40E
Ident. No. 80E,
71E, 62E, 53E, 44E
Aux. switch blocks,
EN 50 011,
4 contacts
Ident. No. 40, 31,
22, 20, 11, 02
Aux. switch blocks,
EN 50 005,
4 or 2 contacts
Ident. No. 80E,
71E, 62E, 53E, 44E
Contactor relay,
EN 50 011
8 contacts
Contactor relay,
EN 50 005,
8 or 6 contacts
Contactor relay, EN 50 011,
4 contacts
Digit of the Order No. 1st -
3rd
4th 5th 6th 7th 8th 9th 10th 11th 12t
h
13th 14th 15th 16th
@@@ @ @ @ @ @ @ @ @ @ @ @ @ @
SIRIUS contactor relays 3 R H
2nd generation 2
Device type (e. g. 1 = 4-pole contactor relay, 3 = 8-pole contactor relay) @
Number of NO contacts (e. g. 2 = 2 NO) @
Number of NC contacts (e. g. 2 = 2 NC) @
Connection type (1 = screw, 2 = spring, 4 = ring lug) @
Operating range / solenoid coil circuit (e. g. A = AC standard / without) @
Rated control supply voltage (e. g. K6 = 110/120 V, 50/60 Hz ) @ @
No significance @
Special version @ @ @ @
Example 3 R H 2 1 2 2 1 A K 6 0
Siemens AG 2011
3RH Contactor Relays
3RH2 contactor relays, 4- and 8-pole
3/60
SIRIUS Innovations Supplement 2011 Illustrations are approximate
3
ISelection and ordering data
AC operation
For other voltages see page 3/62.
For accessories see pages 3/93 to 3/97.
1)
The 3RH21 contactor relays are also available with ring lug terminal con-
nection. Please insert the number "4" into the 8
th
position of the part num-
ber for versions with ring lug terminal connection.
2)
Coil operating range
at 50 Hz: 0.8 to 1.1 x U
s
at 60 Hz: 0.85 to 1.1 x U
s
.
3)
For AC-15/AC-14 the following applies: I
e
= 6 A for mounted auxiliary
contacts.
Size S00
3RH21 . . -1. . . . 3RH21 . . -2. . . . 3RH22 . . -1. . . . 3RH22 . . -2 . . . .
Rated opera-
tional current
at 240 V
Contacts Rated control supply
voltage U
s
at 50/60 Hz
2)
Screw terminals
1)
Weight
approx.
Spring-type
terminals
Weight
approx.
Ident.
No.
Version
Order No. Order No.
A NO NC V AC kg kg
For screw and snap-on mounting onto TH 35 standard mounting rail
Terminal designations according to EN 50011
4 NO, identification number 40E 3 NO + 1 E, identification number 31E 2 NO + 2 NE, identification number 22E
10 40E 4 -- 24 3RH21 40-1AB00 0.220 3RH21 40-2AB00 0.240
110/120 3RH21 40-1AK60 0.220 3RH21 40-2AK60 0.240
220/240 3RH21 40-1AP60 0.220 3RH21 40-2AP60 0.240
31E 3 1 24 3RH21 31-1AB00 0.220 3RH21 31-2AB00 0.240
110/120 3RH21 31-1AK60 0.220 3RH21 31-2AK60 0.240
220/240 3RH21 31-1AP60 0.220 3RH21 31-2AP60 0.240
22E 2 2 24 3RH21 22-1AB00 0.220 3RH21 22-2AB00 0.240
110/120 3RH21 22-1AK60 0.220 3RH21 22-2AK60 0.240
220/240 3RH21 22-1AP60 0.220 3RH21 22-2AP60 0.240
With permanently mounted auxiliary switch block
4 NO + 4 NC, identification number 44E 6 NO + 2 NC, identification number 62E
10
3)
44E 4 4 110/120 3RH22 44-1AK60 0.270 3RH22 44-2AK60 0.300
62E 6 2 110/120 3RH22 62-1AK60 0.270 3RH22 62-2AK60 0.300
13 23 33 43
44 34 24 14 A2( )
A1(+) 1 3 21
22 1 4 A2()
A1 (+) 33
34
43
44
1 3 21
22 1 4 A2()
A1 (+) 31
32
43
44
1 3 61
62 1 4 A2()
A1 (+) 71
72
81
82
23
24
33
34
43
44
51
52
1 3 61
62 1 4 A2()
A1 (+) 71
72
83
84
23
24
33
34
43
44
53
54
Siemens AG 2011

YW

Series

Control Units

8

22

Note: Specify a lens color code in place of


in the Type No.
Clear lenses are used for PW (pure white) illumination of pilot lights.

Pilot Lights

Style Illumination Type Operating Voltage Type No.



Lens Color Code
Flush
Full Voltage

Without Lamp 250V AC/DC max. YW1P-1EQ0


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
LED
6V AC/DC YW1P-1EQ2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-


12V AC/DC YW1P-1EQ3


24V AC/DC YW1P-1EQ4


110V AC/DC YW1P-1EQH


230/240V AC/DC YW1P-1EQM3


Incandescent
6V AC/DC YW1P-1EQ5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T


12V AC/DC YW1P-1EQ6


24V AC/DC YW1P-1EQ7


Flush
Transformer Type

LED
100/110V AC YW1P-1EH2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-6


200/220V AC YW1P-1EM2


115/120V AC YW1P-1EH22


230/240V AC YW1P-1EM42


Incandescent
100/110V AC YW1P-1EH5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T6
200/220V AC YW1P-1EM5


115/120V AC YW1P-1EH25


230/240V AC YW1P-1EM45


Flush Marking Type
Full Voltage

Without Lamp 250V AC/DC max. YW1P-1BEQ0


A (amber), G (green), R (red),
S (blue), W (white), Y (yellow)
LED
6V AC/DC YW1P-1BEQ2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp:
LSED-


12V AC/DC YW1P-1BEQ3


24V AC/DC YW1P-1BEQ4


110V AC/DC YW1P-1BEQH


230/240V AC/DC YW1P-1BEQM3


Incandescent
6V AC/DC YW1P-1BEQ5


A (amber), G (green), R (red),
S (blue), W (white), Y (yellow)
Built-in incandescent lamp: LS-T


12V AC/DC YW1P-1BEQ6


24V AC/DC YW1P-1BEQ7


Flush Marking Type
Transformer Type

LED
100/110V AC YW1P-1BEH2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp:
LSED-6


200/220V AC YW1P-1BEM2


115/120V AC YW1P-1BEH22


230/240V AC YW1P-1BEM42


Incandescent
100/110V AC YW1P-1BEH5


A (amber), G (green), R (red),
S (blue), W (white), Y (yellow)
Built-in incandescent lamp: LS-T6
200/220V AC YW1P-1BEM5


115/120V AC YW1P-1BEH25


230/240V AC YW1P-1BEM45

LP1140-0YW Page 8 Tuesday, August 8, Z006 9:40 AM



YW

Series

Control Units

9

22

Note: Specify a lens color code in place of


in the Type No.
Clear lenses are used for PW (pure white) illumination of pilot lights.

Style Illumination Type Operating Voltage Type No.



Lens Color Code
Extended
Full Voltage

Without Lamp 250V AC/DC max. YW1P-2TEQ0


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
LED
6V AC/DC YW1P-2TEQ2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-


12V AC/DC YW1P-2TEQ3


24V AC/DC YW1P-2TEQ4


110V AC/DC YW1P-2TEQH


230/240V AC/DC YW1P-2TEQM3


Incandescent
6V AC/DC YW1P-2TEQ5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T


12V AC/DC YW1P-2TEQ6


24V AC/DC YW1P-2TEQ7


Extended
Transformer Type

LED
100/110V AC YW1P-2TEH2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-6


200/220V AC YW1P-2TEM2


115/120V AC YW1P-2TEH22


230/240V AC YW1P-2TEM42


Incandescent
100/110V AC YW1P-2TEH5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T6
200/220V AC YW1P-2TEM5


115/120V AC YW1P-2TEH25


230/240V AC YW1P-2TEM45


Dome
Full Voltage

Without Lamp 250V AC/DC max. YW1P-2EQ0


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
LED
6V AC/DC YW1P-2EQ2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-


12V AC/DC YW1P-2EQ3


24V AC/DC YW1P-2EQ4


110V AC/DC YW1P-2EQH


230/240V AC/DC YW1P-2EQM3


Incandescent
6V AC/DC YW1P-2EQ5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T


12V AC/DC YW1P-2EQ6


24V AC/DC YW1P-2EQ7


Dome
Transformer Type

LED
100/110V AC YW1P-2EH2


A (amber), G (green),
PW (pure white), R (red),
S (blue), W (white), Y (yellow)
Built-in LED lamp: LSED-6


200/220V AC YW1P-2EM2


115/120V AC YW1P-2EH22


230/240V AC YW1P-2EM42


Incandescent
100/110V AC YW1P-2EH5


A (amber), C (clear),
G (green), R (red), S (blue),
W (white), Y (yellow)
Built-in incandescent lamp: LS-T6
200/220V AC YW1P-2EM5


115/120V AC YW1P-2EH25


230/240V AC YW1P-2EM45

LP1140-0YW Page 9 Tuesday, August 8, Z006 9:40 AM



YW

Series

Control Units

10

22

Dimensions (Pilot Lights)

2
9
.
8
29.6
2
4

2
9
.
8
29.6
2
4
63.3 9.5
46.2 9.5
Gasket
Locking Ring
M3.5 Terminal Screw
Gasket
Locking Ring
M3.5 Terminal Screw
Panel Thickness 0.8 to 6
Panel Thickness 0.8 to 6

2
9
.
8
29.6
2
4

2
9
.
8
29.6
2
4
63.3 10
46.2 10
Gasket
Locking Ring
M3.5 Terminal Screw
Gasket
Locking Ring
M3.5 Terminal Screw
Panel Thickness 0.8 to 6
Panel Thickness 0.8 to 6
63.3 15.5
M3.5 Terminal Screw
Panel Thickness 0.8 to 6
Panel Thickness 0.8 to 6

2
9
.
8
29.6
2
4

2
9
.
8
29.6
2
4
46.2 15.5
Gasket
Locking Ring
Gasket
Locking Ring
M3.5 Terminal Screw
Panel Thickness 0.8 to 6
Panel Thickness 0.8 to 6
63.3 15.5
Gasket
Locking Ring
M3.5 Terminal Screw

2
9
.
8
29.6
2
4
46.2 15.5
Gasket
Locking Ring

2
9
.
8
29.6
2
4
M3.5 Terminal Screw
All dimensions in mm.
Flush
Full Voltage
Transformer Type
Flush Marking Type
Full Voltage
Transformer Type
Extended
Full Voltage
Transformer Type
Dome
Full Voltage
Transformer Type
LP1140-0YW Page 10 Tuesday, August 8, Z006 9:40 AM
Catalog Dimensions in Inches and (mm)
Type Symbol Amps A E F N C D
2.38 .50 .03 .14 1.44 .54
HRCI-CB CIF06B 1-30A
(60.40) (12.70) (0.81) (3.50) (35.50) (13.80)
HRCI-CB Industrial Ceramic Body Fuse CIF06
Clip-In Mounting
Form No. HRCI-CB
Page 1 of 2
Data Sheet: 4128
Bussmann

6-3-04 SB04168
A
C
D E
N F
Catalog Symbol: CIF06B (1 - 30A)
600Vac; 250Vdc
Interrupting Rating: 200,000A RMS Symmetrical
CSA C22.2 NO. 106-M92 (3-30A only)
Industrial miniature fuse with offset blades for clip-in mounting.
Ground ceramic body with plated endcaps.
Provides both short circuit and overload protection.
CIF06 fits the 30A SafeLOC fuseholder.
Dimensional Data
6-3-04 SB04168
HRCI-CB Industrial Ceramic Body Fuse CIF06
Clip-In Mounting
Form No. HRCI-CB
Page 2 of 2
Data Sheet: 4128
Bussmann

Time/Current-Curves (Cat. No. CIF06) Peak Let-Through Curves (Cat. No. CIF06)
1
0
,
0
0
0
1
,
0
0
0
1
0
0
1
0 1
1,000
100
10
1
.1
CURRENT IN AMPERES
T
I
M
E

I
N

S
E
C
O
N
D
S
.01
361
0
1
5
2
5
3
0
AMPERE
RATING 2
0
1
10
100
1,000
10,000
36
1
0
1
5
2
0
2
5
FUSE RATING (AMPERES)
A
M
P
E
R
E
2

S
E
C
O
N
D
S

(
I
2
t
)
100,000
3
0
Total I
2
t at 600V
Total I
2
t at 460V
Pre-Arcing I
2
t
1
0
0
1
0 1
.
1
1,000
100
10
1
PROSPECTIVE CURRENT (SYM. RMS KA)
P
E
A
K

C
U
R
R
E
N
T

(
K
A
)
0.1
6
10
15
20
25
30
A
M
P
E
R
E
R
A
T
I
N
G
3
Energy Let-Through Curves (Cat. No. CIF06)
Power Dissipation @ Rated Amps
Catalog No. Watts
1CIF06
3CIF06B 1.8
6CIF06B 1.5
10CIF06B 3.4
15CIF06B 2.4
20CIF06B 3.2
25CIF06B 3.6
30CIF06B 3.6
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann
Network Drive. All other copies of this Data Sheet are by definition uncontrolled.This bulletin is intended
to clearly present comprehensive product data and provide technical information that will help the end
user with design applications. Bussmann reserves the right, without notice, to change design or con-
struction of any products and to discontinue or limit distribution of any products. Bussmann also
reserves the right to change or update, without notice, any technical information contained in this
bulletin. Once a product has been selected, it should be tested by the user in all possible applications.