API 510 PREPARATORY Points To Recall Day 2 1. Hydro-Test is Standard Pressure test on Completed Vessels. Hyd. Test Pr. = 1.3 !"#P stress ratio $nsp. Pressure %&ydro' = test pr. ( 1.3 !in. Test temp. = !D!T ) 3*+, !a. $nspection temp. = 12*+, 2. Pneumatic test is per-ormed i- &ydro is not possi.le due to desi/n or process reasons. Prior to t&e test0 1DT as per 2#-3* is mandatory. Pneumatic test pressure = 1.1 !"4P stress ratio0 Pressure s&ould .e increased in steps %Total 5'. 1 st step 3*6 o- test pressure 2 nd to 5 step 1*6 o- test pressure $nsp. Pr. %pneumatic' = test pressure (1.1 3. Pressure /au/e ran/e s&ould .e a.out t7ice t&e test pressure. Ho7e8er0 in any case it s&all not .e lo7er t&an 1.3 times and not &i/&er t&an 9 times t&e test pressure. 9. Vessel !"#P represents t&e maimum sa-e pressure &oldin/ capacity o- t&e 8essel. Vessel !"#P is measured at top-most point. "nd is lo7est o- 8essel part !"#Ps0 ad:usted -or &ydrostatic &ead. 3. ,or 8ertical 8essels0 &ydrostatic pressure caused due to li;uid 7it& speci-ic /ra8ity = 10 1-t o- &ei/&t = *.93 psi/. <r 1 mtr o- &ei/&t = *.1 =ar 5. Total pressure at any point o- Vertical 8essel is /i8en .y> Total Pr. = Vessel !"#P ) & *.933. %& = &ei/&t -rom top in -t.' ?. $- part !"#P and ele8ations are @no7n0 Vessel !"#P can .e calculated .y t&e deductin/ &ydrostatic &ead -rom part !"#P. 1 A. Bt. pressure is 7or@ed out on .asis o- Ceometric -actor " %7&ic& depends on D(Do and Do(t ratios' and -actor = % depends on "0 ' "llo7a.le Bt. Pressure0 Pa = ) / ( 3 4 t Do B E. ,or 8alues o- " -allin/ to le-t o- material line in t&e material c&art> Pa = ) / ( 3 2 t Do AE 1*. 1ame plate s&o7s T&e Code stampin/0 !"#P0 desi/n temp.0 !D!T0 and Btent o- Radio/rap&y. 11. ,or t&e impact test re;uirement0 2CS 55 cur8e. $- !D!T- t&ic@ness com.ination -alls on or a.o8e t&e cur8e0 impact testin/ is eempted. "dditional eemptions are /i8en as per 2C-2*%-' and 2CS=5A %c'. 12. "S!B materials %S"' s&all .e used -or code stamped 8essel -a.rication instead o- "ST! %"' materials. 2