You are on page 1of 4

118L Series Digital Temperature Monitor

118L Series
Digital
Temperature
Monitor

The Qualitrol series 118L offers automatic


and manual cooling control, an exerciser
to automatically and periodically operate
the fans, and a test function for complete
reliability. Options include an analog mA
signal or digital communications through
RS 485 using MODBUS protocol.

UALITROL

The 118L Series Digital


Temperature Monitor offers:
Increased transformer life
Remote communication and control
Peace of mind through fail-safe
operation
Maximized transformer reliability
Ease of installation and use

m a d e

(DTM) puts Qualitrol's knowledge of


accurate, reliable and innovative
temperature monitoring behind your dry
type transformers. The 118L monitors
three or optionally up to four pt100
temperature sensors, displays winding
temperatures, stores maximum
temperatures, and provides relays for fans,
alarms and trip controls.

e a s y

The 118L Digital Temperature Monitor

A u t o m a t i o n

Dont fry
your dry!
THE
Temperature
Monitor for
dry type
transformers

Increased transformer life

The 118L uses digital micro processing technology to control cooling of your
transformer for extended transformer life.
Accuracy is held across the complete range of environmental and power supply
extremes.
A manual fan control button gives you the ability to override presets and turn
on the cooling.
One relay is provided for fan control and a second for alarms, while a third relay
controls additional alarms or trips the transformer off line when temperature
settings are exceeded. Nonstandard conditions such as sensor failure are signaled
by a fourth relay.

Remote communication and control

An optional RS485 data link enables remote communication utilizing MODBUS


RTU protocol. Your 118L will become part of a digital automation system.
An optional mA output loop connects to a SCADA system for remote
data access.

Peace of mind through fail-safe


operation

Sealed membrane UV stabilized front panel.


Approved per Declaration of Conformance, CE.
Continuous self-diagnostics keep you informed and our equipment protected.
Loss of power will operate the fault alarm. The alarm and trip relays can also be
configured to operate on power failure.

Maximized transformer reliability

Protected to withstand surges, electrical noise, radio frequencies and electromagnetic


interference.
The 118L detects abnormal conditions and places transformer in safe operating
condition with fans on and fault alarm on so the transformer can continue
to function.
A fan exerciser, if activated, periodically turns the fans on for short intervals to
prevent seizure of the fan motor bearings.
A test function shows stored set points, and tests the digital display.

Ease of installation and use

A standard RS232 data port allows you to quickly link to a computer to configure
parameters using Qualitrol-supplied software (KIT-118L-1). The setup program is
simple to operate.
The mA loop output can easily be set to either 0-1 to 4-20 mA via the front
panel or the RS232 data port.
Highly readable scrolling LCD display.
Easily understood display icons indicate relay status at a glance.
The universal power supply accommodates a wide range of supply voltages.

Technical Specifications

Performance

Power Supply:

Universal 85 to 265 VAC or 20 to 280 VDC

Measurement Range:

0-200 C

Accuracy:

1% at ambient temperatures of 0 to 60 C,
1.5% at ambient temperatures of -30 to 0 C and +60 to 70 C

Display:

3-digit LCD

Memory Retention

10 years (with power off )

Switch Ratings:

5A @ 250 VAC or 30 VDC resistive load


0.2A @ 300 VDC resistive load

Remote Output Current Loop: 0-1 mA (10,000 ohms max.) or 4-20 mA (500 ohms max.)

Operating Temperature:

-30 to +70 C

Storage Temperature:

-50 to +85 C

Relative Humidity:

90% (non-condensing)

Hi-pot:

2300 VAC for 1 minute power or relay contact to ground, or from


power input to electronic ground (power supply secondary)

Vibration:

50 to 180 Hz. @ .004 displacement

Shock:

10g in 3 orthogonal planes

Size:

3.78 x 3.78 (96X96 mm), 3.94 100ohm deep


DIN 1/4 cut out 3.62 x 3.62 (92X92 mm)

Weight:

0.97 lbs. (440 g)

Front Membrane Panel:

Graphic overlay UV stabilized Polyester

Mounting:

1/4

Electrical Screw Terminals:

Screw terminal; maximum 12 gage wire

Declaration of
Conformance CE:

EN50081-1 (emissions)
EN61000-6-2 (immunity)
EN61010-1 (safety)

Mechanical

Approvals

DIN square cutout 3.62 x 3.62


(92 mm x 92 mm)

118L Series Electronic Temperature Monitor

Environmental

4.28
(108.71 mm)
5.40 (137.16 mm)
6.50(165.1 mm)

.281x.281 sq.
(7.14 x 7.14 mm)
typ. 3 plcs.

8.82 (224.03 mm)


6.80 (172.72 mm)

1.00 (25.4 mm)

.281
(7.14 mm)
3 plcs.

13.60
(345.44 mm)

9.10
(231.14 mm)

8.00
(203.2 mm)

7.13
(181.10 mm)

15.12
(384.05 mm)

.55
(13.97 mm)

14.25
(361.95 mm)

.38
(9.65 mm)
.265
(6.73 mm)
4 plcs.

.38
(9.65 mm)

2.70
(68.58 mm)

4.78
(121.41 mm)

Panel Mount Version

7.94
(201.68 mm)

Hinged Mount Version

The product number defines the selected features:


118L-___-___-___-___

118L Series Electronic


Temperature Monitor

M = MODBUS, X = no MODBUS
A = milliamp loop, X = no milliamp loop

Ordering Information

P = Pt100 RTD inputs


3 = 3 inputs, 4 = 4 inputs
The base unit is 118L-3-P-X-X

UALITROL
C

Qualitrol Corporation
1385 Fairport Road
Fairport, New York 14450
USA

Phone:
585-586-1515
Fax Orders: 585-377-0220
Fax Quotes: 585-377-9613

E-mail: info@qualitrolcorp.com
www.qualitrolcorp.com

AB Qualitrol AKM
Flygfltsgatan 6C
S - 128 30 Skarpnck
Sweden

Phone: +46 8 931050


Fax:
+46 8 604810

E-mail: info@akmsweden.com
www.akmsweden.com

Qualitrol 2005 Qualitrol and Qualitrol AKM are ISO 9001 system certified companies