You are on page 1of 7

Professional Training and Consultation

SET J
API 510 Preparatory Course
1. A filmside penetrameter can be used for:
a. inaccessible welds (unable to hand place a source
penetrameter)
b. all welds
c. all castings at any time
d. an alternative to a source-side wire penetrameter
2. A dark image of the "B" on a lighter background is:
a.
b.
c.
d.

Acceptable
Rejectable
Sometimes rejectable
None of the above

3. One of the procedural requirements for conducting PT is


to address the processing details for:
a.
b.
c.
d.

Post-examination cleaning
Pre-examination cleaning
Apply the penetrant
All of the above

4. Non-aqueous developer may be applied to a wet


surface.
True

or

False

(circle one)

5. The accuracy of a piece of magnetizing equipment that


is equipped with an ammeter shall be verified:
a.
b.
c.
d.

Each year
Each two years
When possible
Every 6 months

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

91

Professional Training and Consultation

6. When using fluorescent particles, the examiner shall be


in a darkened area for at least ________ minutes prior
to performing the examination.
a.
b.
c.
d.

7
10
9
1

7. A wire IQI shall be placed adjacent to the weld, with the


wires parallel to the weld.
True

of

False (circle one)

8. A field indicator is composed of _______low carbon


steel pie sections, furnace brazed together.
a.
b.
c.
d.

2
6
10
8

9. The type and amperage of magnetizing current must be


identified on the written MT procedure.
True of
10.

False (circle one)

Certification of contaminants shall be obtained for all


PT materials used on:

a. Carbon steels
b. Ferritic stainless steels
c. Austenitic stainless steels
d. None of the above
11. Black light intensity shall be measured with a
_______ when conducting fluorescent PT.
a. Dark room meter
b. Photo-meter
c. Black light meter
d. None of the above
P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

92

Professional Training and Consultation

12.

When should a densitometer be calibrated as a


minimum?
a.
b.
c.
d.

13.

Annually
Every 90 days
Whenever it is turned on
As required by the Examiner

The location markers required by ASME V are


required to appear as radiographic images.
True or

14.

False

(circle one)

When coatings are applied to enhance contrast, the


procedure must be demonstrated that indications
can be detected through the coating.
True or

16.

(circle one)

D.C.yokers may be used for detecting subsurface


discontinuities, per ASME V?
True or

15.

False

False (circle one)

How many total liquid penetrant techniques are


listed in ASME V?
a.
b.
c.
d.

4
6
2
1

17.

Prior to examinations, each adjacent surface shall be


cleaned within at least _____" of the area to be
examined.
a. 1
b. 1.5
c. 2
d. 3

18.

Water washable penetrant shall be removed with a


water spray not exceeding 60 psi and 1000F.

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

93

Professional Training and Consultation

True or
19.

The maximum emulsification time shall be :


a.
b.
c.
d.

20.

pre-flooding with emulisifier


pre-cleaning with solvent
pre-rinsing with water
pre-washing with detergent

A welded part is to be radiographed and is 1" thick,


with 1/8" reinforcement. What ASTM wire set IQI
should be used on these radiographs if a source side
technique is used :
a.
b.
c.
d.

23.

Densitometer
Step Wedge Comparison Strip
Light Meter
Transmission monitor

When using a hydrophillic emulsifier versus a


lipophilic emulsifier and intermediate step that must
be taken is:
a.
b.
c.
d.

22.

5 minutes
10 minutes
15 minutes
none of the above

Densitometers shall be calibrated by verification with


a calibrated:
a.
b.
c.
d.

21.

False (circle one)

Set
Set
Set
Set

A
B
C
D

When a PT test cannot be conducted between 5001250F, what must be done, per ASME V?
a. The procedure must be qualified.

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

94

Professional Training and Consultation

b. The surface must be re-cleaned


c. The test cannot be conducted
d. None of the above
24.

The sulphur content of a penetrant is measured to be


less than 0.0025g. This material is acceptable for use
on:
a.
b.
c.
d.

25.

All indications are to be evaluated in accordance


with:
a.
b.
c.
d.

26.

Nickel-base alloys
Carbon steel
Ferritic steel
All of the above

ASME VIII
ASME V
The referencing Code section
The written procedure

The scope of the ASME Boiler and Pressure Vessel,


Code, Section V includes:
a.
b.
c.
d.

NDE acceptance crtieria


How to perform NDE to achieve a desired result
Where to do NDE (i.e. what welds to examine)
Who can be the Authorised Inspector

27.

UT equipment is calibrated?
a. Before heat-treatment
b. AFter completing the examination
c. Prior to visual examination
d. Prior to PT examination

28.

What finished surface is required of butt welds for PT


examination?
a. Smooth surface prepared by grinding
b. Cosmetically clean acid etched surface

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

95

Professional Training and Consultation

c. A near white blast surface


d. None of the above
29.

A penetrameter is used on a DWE/DWV. The


penetrameter selection is based on:
a.
b.
c.
d.

30.

A suitable means for applying penetrant.


a.
b.
c.
d.

31.

The single wall thickness and weld reinforcement


Both wall thicknesses
The single wall thickness for Sch 80 pipe
None of the above

Dipping
Brushing
Spraying
Any or all of the above

What materials require the use of tested and


certified liquid penetrants as to the contaminants in
the penetrant?
a.
b.
c.
d.

Nickel alloys
Austenitic stainless steel alloys
Ferritic / martensific stainless steel
Both a and b, above

32.

How shall indications be evaluated, i.e. acceptance


standards for RT?
a. To ASME V
b. To ASME VIII
c. To B31.3
d. To the referencing Code section

33.

Thickness readings may be displayed on?


a.
b.
c.
d.

SRT
PRT
CRT
Strip chart recorder

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

96

Professional Training and Consultation

34.

How many copies of a procedure must be available


to the Manufacturers NDE Personnel?
a.
b.
c.
d.

35.

How shall Non-destructive Examination Personnel be


qualified?
a.
b.
c.
d.

36.

To
To
To
To

SNT-TC 1A
CP-189
referencing code requirements
ACCP rules

Which NDE
methods?
a.
b.
c.
d.

37.

1
2
3
4

methods

are

considered

"surface"

PT
RT
MT
Both A & C above

What designation is used to indicate the


penetrameter is on the film side?
a.
b.
c.
d.

An "F"
An " E"
A " D"
An "FS"

P.O. Box No. 7274, Dammam 31462, Saudi Arabia TEL (966) 3 857 0006 FAX (966) 3 857 5255
info@gotoITC.com www.gotoITC.com

97

You might also like