You are on page 1of 6

Kv = Cv * 0.

864
Cv = Kv * 1.157
1 bar = 14.22 PSI
1 PSI = 0.07031 bar
1 bar = 0.1 MPa

Air
N2
O2
H2
CH4

1.293
1.251
1.429
0.0899
0.717

kg/m3
kg/m3
kg/m3
kg/m3
kg/m3

Zimmerli Messtechnik AG Riehen


+41 61 645 98 00
info@zimmerli-inert.com
www.zimmerli-inert.com

Calculation acc. to Calame a. Hengst


Only for gases
Only for low pressure regulator ZM-R, ZM-B and LPR, LPS

1 MPa = 10 bar

1st step:
Enter all known application / process parameters first
Kv results upon completion

Seat
Primary pressure
Secondary pressure
Differential pressure
Inert gas
Ambience/ process
Target flow
Theoretically
Sizing

Kv =
p1 =
p2 =
Delta p =
Density =
Temperature =
Gas =
Gas =
Gas =

6.500
3.000
1.000
2.000
1.251
20.0
102.000
261.761
204.000

www.zimmerliag.com

Quotation No:
Order No:
Tag No:
Tag No:
Tag No:
2nd step:
P1 3.000
If required,
test a different Kv
(seat) from
the data sheet
0.000
Rule: (Kv
Seat Kv Sizing)
0.000

bar absolute
bar absolute
bar
KV* is critical or too small!
kg/m3
C
Kv values
Nm3/h
6.500
Kv Seat
Nm3/h
Nm3/h
5.066
Kv Sizing

Result for reducer


LPR, ZM-R

Differential pressure sufficient for calculation


Seat and Kv sufficient, test lower Kv value, if required

Result for relief valve


LPS, ZM-B

Differential pressure sufficient for calculation


Seat and Kv sufficient, test lower Kv value, if required

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010

1.50

Kv target
261.76

1.293
1.251
1.429
0.0899
0.717

kg/m3
kg/m3
kg/m3
kg/m3
kg/m3

Kv = Cv * 0.864
Cv = Kv * 1.157
1 bar = 14.22 PSI
1 PSI = 0.07031 bar
1 bar = 0.1 MPa

Air
N2
O2
H2
CH4

Zimmerli Messtechnik AG Riehen


+41 61 645 98 00
info@zimmerli-inert.com

1 MPa = 10 bar

Calculation acc. to Calame a. Hengst

www.zimmerli-inert.com
www.zimmerliag.com

Only for gases


Only for mid-range pressure regulator PR, PPR and reflux blocking valve PRR

1st step:
Enter all known application / process parameters first
Kv results upon completion

Seat
Primary pressure
Secondary pressure
Differential pressure
Gas
Ambience/ process
Target flow
Theoretically
Sizing

Kv =
p1 =
p2 =
Delta p =
Density =
Temperature =
Gas =
Gas =
Gas =

3.00
4.000
1.000
3.000
1.251
20.0
102.000
161.084
128.867

Quotation No:
Order No:
Tag No:
Tag No:
Tag No:

2nd step:
P1 4.000
If required,
testa different Kv
the data sheet
bar absolute (seat) from
0.000
Rule:
(Kv
Seat
bar absolute
0.000 Kv Sizing)
bar
KV* is critical or too small!
2.00
3
kg/m
C
Kv values
Nm3/h
3.00
Kv Seat
Nm3/h
Nm3/h
2.37
Kv Sizing
161.0838142

Result for P-series


for gases

Differential pressure sufficient for calculation


Seat and Kv sufficient, test lower Kv value, if required

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010

with 20% safety

Kv = Cv * 0.864
Cv = Kv * 1.157
1 bar = 14.22 PSI
1 PSI = 0.07031 bar
1 bar = 0.1 MPa
1 MPa = 10 bar

Water
Benzol
Silicone oil
Trichloretylene

1.00
0.88
0.94
1.47

kg/dm3
kg/dm3
kg/dm3
3
kg/dm

Zimmerli Messtechnik AG Riehen


+41 61 645 98 00
info@zimmerli-inert.com

Flow calculation
acc. to Calame a. Hengst

www.zimmerli-inert.com
www.zimmerliag.com

Only for liquids


Only for mid-range pressure regulator PR, PPR and reflux blocking valve PRR

1st step:
Enter all known application / process parameters first
Kv results upon completion

Seat
Primary pressure
Secondary pressure
Differential pressure
Liquid
Ambience/ process
Target flow
Theoretically
Sizing

Kv =
p1 =
p2 =
Delta p =
Density =
Temperature =
Liquid =
Liquid =
Liquid =

Quotation No:
Order No:
Tag No:
Tag No:
Tag No:

9.00
4.000
1.000
3.000
1.251
20.0
10.000
13.937
11.150

2nd step:
P1 4.000
If required,
test a different Kv
the data sheet
bar absolute (seat) from
0.000
Rule:
(Kv
Seat
bar absolute
0.000 Kv Sizing)
bar
KV* is critical or too small!
2.00
3
kg/dm
C
Kv values
m3/h
9.00
Kv Seat
m3/h
m3/h
8.07
Kv Sizing
483.2514425

Result for P-series


for liquids

Differential pressure sufficient for calculation


Seat and Kv sufficient, test lower Kv value, if required

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010

with 20% safety

Zimmerli, Inertization
Reducer type
Seat-

Kv value

LPR25 [mbar]

Back pressure type


Seat-
Kv value
LPS25 [mbar]

2.0 mm
4.5 mm
7.5 mm

0.15
0.65
1.25

ZM-R15 [mbar]
ZM-R25 [mbar]

18mm

6.50

ZM-B15 [mbar]
ZM-B25 [mbar]

2.0 mm
4.5 mm
7.5 mm
10 mm
14 mm

0.15
0.65
1.25
2.00
2.50

18 mm

3.00
7.00
15.00

26 mm

35.00
70.00

55 mm

ZM-R50 [mbar]

6.50

ZM-B50 [mbar]

14 mm
18 mm
26 mm

ZM-R100 [mbar]

15.00

ZM-B100 [mbar]

42 mm
55 mm

70.00

Zimmerli, pressure regulator


PR15 [PN40]

PPR15 [PN40]

11 mm, Viton, EPDM


11 mm, HC, PTFE

1.50
1.50

11 mm, Viton,EPDM
11 mm, HC, PTFE

2.80
4.80

17 mm, Viton,EPDM
17 mm, HC, PTFE

3.00
7.00
10.00
15.00

14 mm
18 mm
26 mm, HC, PTFE
26 mm, Viton,EPDM

35.00
70.00

42 mm
55 mm

PR25 [PN40]

PPR25 [PN40]

17 mm, HC, PTFE


17 mm, Viton,EPDM

PR50 [PN16]

PR100 [PN16]

3.00
7.00
10.00
15.00

PPR100 [PN16]

42 mm
55 mm

Zimmerli, reflux blocking valve


PRR15 [PN40]
11 mm, Viton, EPDM
11 mm, HC, PTFE

1.50
1.50

PRR25 [PN40]
17 mm, HC, PTFE
17 mm, Viton,EPDM

2.80
4.80

PRR50 [PN16]
15.00

PRR100 [PN16]
55 mm, PTFE

2.80
4.80

PPR50 [PN16]

14 mm
18 mm
26 mm, HC, PTFE
26 mm, Viton,EPDM

26 mm, PTFE

1.50
1.50

70.00

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010

35.00
70.00

Weather effects
Temperature drop: VA [m3/h]

Heating: VE [m3/h]

LPR, ZM-R

LPS, ZM-B
3

Additional shielding gas volume flow VA [m /h], which must be


supplied in case of a temperature drop. Concerns:
- Outdoor tanks
- without temperature insulation

Additional shielding gas volume flow VE [m3/h], which must be


discharged in case of heating. Concerns:
- Outdoor tanks
- without temperature insulation

Important for the calculation in case of a temperature drop:


- Tank discharging gradient, pump output [m3/h]
- Weather factor in case of uninsulated outdoor tanks
VA = 4.8*VB0.71
VA = Volume flow in cooling (e.g. thunder storm) [m3/h]
VB = Tank volume [m3]
Source: TRbF120

Important for the calculation of the volume flow:


- Tank filling gradient, pump output [m3/h]
- Weather factor in case of uninsulated outdoor tanks
VE=0.17*(H/D)-(0.52)*VB0.89
VE = Volume flow due to warming [m3/h]

Example:

Example:

VB = Tank volume [m3]


H = Tank jacket height [m]
D = Tank diameter [m]
Source: TRbF120

VB [m ]

VA [m /h]

VB [m3]

H [m]

D [m]

VE [m3/h]

105

130.703

105

8.202

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010

Comments concerning
pressure reducing valve

Comments concerning
pressure relief valve

LPR, ZM-R

LPS, ZM-B

Always choose a Kv value which is sufficiently high and, if


possible, never chose the Kv value which is too low.

Always choose a Kv value which is sufficiently high and, if


possible, never chose the Kv value which is too low.

Important for the calculation of the volume flow:


- Tank discharge gradient, pump output [m3/h]
- Weather factor in case of uninsulated outdoor tanks
VA = 4.8*VB0.71

Important for the calculation of the volume flow:


- Tank filling gradient, pump output [m3/h]
- Weather factor in case of uninsulated outdoor tanks
VE=0.17*(H/D)-(0.52)*VB0.89

VA = Volume flow in case of cooling (e.g. thunder storm)


[m3/h]

VE = Volume flow due to warming [m3/h]

If the Kv indication states too high and the selection of the


next lower Kv states too low, always select the higher Kv
value.

If the Kv indication states too high and the selection of the


next lower Kv states too low, always select the higher Kv
value.

Attention please:
The flow calculation is already designed for twice the
theoretical value. Avoid further flow doubling since this
might cause an unfavourable control behaviour.

Attention please:
The flow calculation is already designed for twice the
theoretical value. Avoid further flow doubling since this
might cause an unfavourable control behaviour.

PR

PPR

Starting at a pressure difference of < 3bar above the


valve, the control behaviour is increasingly unlinear.
The possible maximum flow quantities strongly decrease
and partly amount to merely 1/10 of the calculated value.
In extreme cases, the flow is even 0.

Starting at a pressure difference of < 3bar above the


valve, the control behaviour is increasingly unlinear.
The possible maximum flow quantities strongly decrease
and partly amount to merely 1/10 of the calculated value.
In extreme cases, the flow is even 0.

The flow calculation in relation to the theoretical value is


based on 20% safety.

The flow calculation in relation to the theoretical value is


based on 20% safety.

Comment:
ZM_KV_IDAG_e2, under reserve of modifications, Zimmerli Messtechnik AG, Edition: March 2010