You are on page 1of 4

Code: LLM18-QP-04.

14/FU
Rev.: 0
Date :
Total Page: 1

FIT-UP DIMENSIONAL INSPECTION


REPORT
Report No.: FUClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-

Item: CCM SECONDARY SUCTION SYSTEM ABOVE TURRET

Drawing No.: AJ-2437-Z30-002

No.

Location

Drawing Dim.

L1

1602

L2

102

L3

500

L4

500

L5

2760

L6

630

L7

500

L8

500

L9

500

10

L10

1602

11

L11

102

12

L12

500

13

L13

500

14

L14

2760

15

L15

630

16

L16

500

17

L17

500

18

L18

500

19

L19

2760

20

L20

2760

21

OD21

1360

22

OD22

1360

23

OD23

1360

24

OD24

1360

Actual Dim.

Deviation

Tolerance

(attached)

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:

Name:

Date:

Date:
Page 1/4

Remarks

Code: LLM18-QP-04.14/DI
Rev.: 0
Date :
Total Page: 1

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.: DIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-

Item: CCM SECONDARY SUCTION SYSTEM ABOVE TURRET

Drawing No.: AJ-2437-Z30-002

No.

Location

Drawing Dim.

L1

1602

L2

102

L3

500

L4

500

L5

2760

L6

630

L7

500

L8

500

L9

500

10

L10

1602

11

L11

102

12

L12

500

13

L13

500

14

L14

2760

15

L15

630

16

L16

500

17

L17

500

18

L18

500

19

L19

2760

20

L20

2760

21

OD21

1360

22

OD22

1360

23

OD23

1360

24

OD24

1360

Actual Dim.

Deviation

Tolerance

(attached)

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:

Name:

Date:

Date:
Page 2/4

Remarks

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2437-Z30-002

Item: CCM SECONDARY SUCTION SYSTEM ABOVE TURRET

Test & Inspection


procedure

Item
No.
A

Acc.

Rej.

VISUAL CHECK FOR WELD


Fillet weld (leg length or throat
depth)

Acceptance criteria

Intermittent weld
a) Intermittent pitch
b) Weld length

Linear misalignment in
butt weld

Leg length and throat depth shall not be


less than design dimensions on drawing.
When not specified on drawing, throat
depth shall be minimum 0.7t. Where t:
thickness of a thinner plate at welded
plates.
Intermittent pitch shall be between +/-10
mm of design values on drawing.
Weld length shall be between -5 and
+10 mm of design values on drawing.
Linear misalignment shall be not excess
10% of plate thickness at welds, but
maximum 3.0mm.

Unevenness in bead surface


Depth D shall be 2 mm or less for
50mm long weld.

4
Irregularity in bead width
5

Difference in bead widths (a - b) shall be


5 mm
or less for 50 mm long weld.
a b < 3 mm

Overlap
Overlap shall be 1.5 mm. or less per 100
mm long in bead direction.

6
Undercut

Depth of undercut shall be 1.0 mm or


less.

7
Crater treatment
8

Craters shall have been treated.

Pit

No pits shall exist.

10

Slag inclusion

No included slag shall exist.

11

Crack

No cracks shall exist.

12

Spatter

Spatters shall be removed.


Conclusion

Accepted

Rejected

Remark

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2437-Z30-002

Item: CCM SECONDARY SUCTION SYSTEM ABOVE TURRET

Item
No.

Test & Inspection


procedure

Acceptance criteria

Acc.

VISUAL CHECK FOR SHAPE/SIZE

Contused wound, hammer


wound, irregularity, etc.

These wounds shall be ground for


inconspicuous and smooth surfaces.

Finished conditions after


removing temporary jigs used
during manufacture.

Smoothing shall reach the base


metal. Concave portions shall
be repaired

Contamination, stuck foreign


Cleaning has been done. No foreign
materials, and foreign materials
materials shall exist.
left in equipment.

Inclination, bend and deflection.

These defects shall not been visually


detected.

Matching marks:
1) Orientation marks
(00,900,1800,2700)
2) Center line mark

Marking shall be made.

Finished conditions at convex


and corner portions (for lined
products).

Finish shall be smooth (min. 2R).

Finished conditions at concave


and corner portions (for lined Finish shall be smooth (min. 5R).
products).

Corners in bolt holes mounting


strainers for water collecting
plates, lining attaching internal Parts to be lined shall have corners
parts, external surfaces of
chamfered (min. 1C).
flanges, and bolt holes in
flanges.
Conclusion
LILAMA 18
Prepared/Inspected

Sign
Name:
Date:

Inspected/Reviewed

Accepted

Rej.

Rejected

VKS
Reviewed/Approved

Remark

You might also like