You are on page 1of 12

GE Consumer & Industrial

Power Protection

Tele REC
The Ultimate
Reconnection System

10

GE imagination at work

New
2008

Tele REC reconnecti


Ensures power cont
The Tele REC relay automatically recluses the RCCB after an earth leakage or a
manual disconnect. The relay will attempt to re-close 6 times with different time intervals between re-close attempts. After 6 unsuccessful attempts the Tele REC is locked.

RCCB

Close
1

10

20

30

60

10

Timer

Tele REC DMS

Residential

DMS line

New

Tele REC BASIC


Commercial,
Banks,
Ofce buildings,
Hospitals

Farms, Public
lighting, Trafc
lighting

Redline

2008

Easy connection
The RCCB toggle slides easily
into the toggle actuator of
the relay.

Auxiliary contact

ElfaPlus
Redline
DMS line

Status indicator

Part of the family

The yellow lever clearly indicates


the status of the Tele REC.
In position 1 the relay is
ready to work, in position
0 the relay is blocked both
electrically and mechanically.

For each series of RCCBs ElfaPlus, Redline and DMS


line - a specic Tele REC
reconnector is available.

Tele REC is equipped with


an auxiliary contact (LI) to
operate the re-closing system from a push-button.

ng system for RCCBs

Tele REC PLUS

Industry

ElfaPlus
Full awareness
The relay is also equipped
with a volt free output to
indicate the status of the
protection (connected/ disconnected).

Stable and secure

One ts all

Strong clips to ensure a


stable connection between
the RCCB and the Tele REC
relay.

Both 2 modules and 4 modules RCCBs can be connected to the reconnection


relay Tele REC.

Tele REC
Complete range of reconnection relays

Tele REC DMS


Specially designed
for the residential
market

Tele REC BASIC


For the residential/
commercial markets

Tele REC BASIC Ai


Power maintenance
and reliability
in one device

Tele REC PLUS


For the commercial/
industrial markets

Tele REC SOLAR


Specially designed
for photovoltaic
applications

Tele REC
Specially designed for the residential market
Series Tele REC DMS - Type AC
30 mA
2P
Type AC

In (A)

Cat. No.

Ref. No.

Pack.

25
40

Tele REC DMS 225/30


Tele REC DMS 240/30

677116
677117

1
1

Electrical diagram

Tele REC DMS

Manual re-closing
with push-button
REC DMS

I : automatic operation
Manual switch (yellow lever)
O : self-reclosing not allowed

Tele REC
For the residential/commercial market
Series Tele REC BASIC - Type AC

Tele REC BASIC

30 mA
In (A)

Cat. No.

Ref. No.

Pack.

2P
Type AC

40
63

Tele REC BASIC 240/030


Tele REC BASIC 263/030

676949
677118

1
1

4P
Type AC

40
63

Tele REC BASIC 440/030


Tele REC BASIC 463/030

676951
677119

1
1

In (A)

Cat. No.

Ref. No.

Pack.

2P
Type AC

40
63

Tele REC BASIC 240/300


Tele REC BASIC 263/300

676950
677120

1
1

4P
Type AC

40
63

Tele REC BASIC 440/300


Tele REC BASIC 463/300

676952
677121

1
1

300 mA

Series Tele REC BASIC - Type A


30 mA
In (A)

Cat. No.

Ref. No.

Pack.

2P
Type A

40
63

Tele REC BASIC A 240/030


Tele REC BASIC A 263/030

677122
677123

1
1

4P
Type A

40
63

Tele REC BASIC A 440/030


Tele REC BASIC A 463/030

677124
677125

1
1

In (A)

Cat. No.

Ref. No.

Pack.

2P
Type A

40
63

Tele REC BASIC A 240/300


Tele REC BASIC A 263/300

677126
677127

1
1

4P
Type A

40
63

Tele REC BASIC A 440/300


Tele REC BASIC A 463/300

677128
677129

1
1

300 mA

Electrical diagram

Manual re-closing
with push-button
REC BASIC

I : automatic operation
Manual switch (yellow lever)
O : self-reclosing not allowed

Tele REC
Power maintenance and reliability in one device
Series Tele BASIC - Type Ai
30 mA
2P
Type Ai

In (A)

Cat. No.

Ref. No.

Pack.

40
63

Tele REC BASIC Ai 240/030


Tele REC BASIC Ai 263/030

677130
677131

1
1

Electrical diagram

Tele REC BASIC

Manual re-closing
with push-button
REC BASIC

I : automatic operation
Manual switch (yellow lever)
O : self-reclosing not allowed

The complete solution in only one device:

Total protection against persons indirect contacts.


Safe reconnection of RCCB after trip by transitory earth leakage.
Maintenance of power against trips provoked by high frequency earth leakages.
Maintenance of power against shock waves up to 3000 A.

Tele REC
For the commercial/industrial market
Series Tele REC PLUS
Reconnection relay
Reconnection relay

Cat. No.

Ref. No.

Pack.

Tele REC PLUS Motor

677132

The reconnection relay Tele REC Plus can be easily coupled to any RCCB:
RCCB Series FP - Type AC

Tele REC PLUS

In (A)

10*/30mA
2P
Type AC
1/2

3 /4

2 /1

4 /3

4P
Type AC
1/2

3/4 5/6

2 /1

4/3 6/5

100mA

300mA

In (A)

Cat. No.

Ref. No.

Cat. No.

Ref. No.

Cat. No.

Ref. No.

Pack.

25*
25
40
63
80
100

FP 225/010
FP 225/030
FP 240/030
FP 263/030
FP 280/030
FP 2100/030

604193
604250
604252
604254
604064
604069

FP 225/100
FP 240/100
FP 263/100
FP 280/100
FP 2100/100

604050
604055
604060
604065
604070

FP 225/300
FP 240/300
FP 263/300
FP 280/300
FP 2100/300

604251
604253
604255
604066
604071

1/6
1/6
1/6
1/6
1/6
1/6

25
40
63
80
100

FP 425/030
FP 440/030
FP 463/030
FP 480/030
FP 4100/030

604256
604258
604260
604158
604163

FP 425/100
FP 440/100
FP 463/100
FP 480/100
FP 4100/100

604144
604149
604154
604159
604164

FP 425/300
FP 440/300
FP 463/300
FP 480/300
FP 4100/300

604257
604259
604261
604160
604165

1/3
1/3
1/3
1/3
1/3

Ref. No.

Cat. No.

Ref. No.

Pack.

RCCB Series FPA - Type A


10*/30mA
In (A)
2P
Type A
1/2

3 /4

2 /1

4 /3

4P
Type A
1/2

3/4 5/6

2 /1

4/3 6/5

Cat. No.

100mA
Ref. No.

FPA 216/010
FPA 225/030
FPA 240/030
FPA 263/030
FPA 280/030
FPA 2100/030

604000
604001
604006
604011
604016
604021

FPA 225/100
FPA 240/100
FPA 263/100
FPA 280/100
FPA 2100/100

604002
604007
604012
604017
604022

FPA 225/300
FPA 240/300
FPA 263/300
FPA 280/300
FPA 2100/300

604003
604008
604013
604018
604023

1/6
1/6
1/6
1/6
1/6

25
40
63
80
100

FPA 425/030
FPA 440/030
FPA 463/030
FPA 480/030
FPA 4100/030

604096
604101
604106
604111
604116

FPA 425/100
FPA 440/100
FPA 463/100
FPA 480/100
FPA 4100/100

604097
604102
604107
604112
604117

FPA 425/300
FPA 440/300
FPA 463/300
FPA 480/300
FPA 4100/300

604098
604103
604108
604113
604118

1/3
1/3
1/3
1/3
1/3

Ref. No.

Pack.

604028
604032
604036
604040

1/6
1/6
1/6
1/6

Ref. No.

Pack.

604124
604128
604132
604136

1/3
1/3
1/3
1/3

100mA
In (A)

1/2

3 /4

2 /1

4 /3

40
63
80
100

Cat. No.
FPS 240/100
FPS 263/100
FPS 280/100
FPS 2100/100

1/2

3/4 5/6

2 /1

4/3 6/5

40
63
80
100

Cat. No.
FPS 440/300
FPS 463/300
FPS 480/300
FPS 4100/300

S
300mA

Ref. No.
604026
604030
604034
604038

100mA
In (A)
4P
Type S

300mA

16*
25
40
63
80
100

RCCB Series FPS - Type S

2P
Type S

Cat. No.

Cat. No.
FPS 240/300
FPS 263/300
FPS 280/300
FPS 2100/300

500mA
Ref. No.
604027
604031
604035
604039

300mA
Ref. No.
604122
604126
604130
604134

Cat. No.
FPS 440/500
FPS 463/500
FPS 480/500
FPS 4100/500

Cat. No.
FPS 240/500
FPS 263/500
FPS 280/500
FPS 2100/500

500mA
Ref. No.
604123
604127
604131
604135

Cat. No.
FPS 440/1000
FPS 463/1000
FPS 480/1000
FPS 4100/1000

Tele REC
RCCB Series FPAi - Type Ai
30mA
In (A)
2P
Type Ai
1/2

3 /4

2 /1

4 /3

4P
Type Ai
3/4 5/6

2 /1

4/3 6/5

Ref. No.

Pack.

25
40
63

FPAi 225/030
FPAi 240/030
FPAi 263/030

604042
604044
604046

1/6
1/6
1/6

25
40
63

FPAi 425/030
FPAi 440/030
FPAi 463/030

604137
604139
604141

1/3
1/3
1/3

RCCB Series FPSi - Type Si


300mA
In (A)
2P
Type Si

40
63
80
100

Cat. No.
FPSi240/100
FPSi263/100
FPSi280/100
FPSi2100/100

604346
604347
604348
604349

300mA
In (A)
4P
Type Si

40
63
80
100

Cat. No.
FPSi440/300
FPSi463/300
FPSi480/300
FPSi4100/300

S
500mA

Ref. No.

Cat. No.
FPSi240/300
FPSi263/300
FPSi280/300
FPSi2100/300

1000mA
Ref. No.
604351
604352
604353
604354

500mA
Ref. No.
604371
604372
604373
604374

Tele REC PLUS

1/2

Cat. No.

Cat. No.
FPSi440/500
FPSi463/500
FPSi480/500
FPSi4100/500

Cat. No.
FPSi240/500
FPSi263/500
FPSi280/500
FPSi2100/500

Ref. No.

Pack.

604356
604357
604358
604359

1/6
1/6
1/6
1/6

Ref. No.

Pack.

604381
604382
604383
604384

1/3
1/3
1/3
1/3

1000mA
Ref. No.
604376
604377
604378
604379

Cat. No.
FPSi440/1000
FPSi463/1000
FPSi480/1000
FPSi4100/1000

Electrical diagram

Manual re-closing
with push button
REC PLUS

I : automatic operation
Manual switch (yellow lever)
O : self-reclosing not allowed

=
9

Tele REC

Tele REC PLUS

Mounting instructions Tele REC PLUS


1.

2.

Place the reconnection relay on a at


surface and lock relay in OFF position
using the yellow sliding lever.

Install the toggle actuator in the relay.

3.

4.

5.

Ensure RCCB is OFF. Align relay and RCCB.


Check the make and model of RCCB.
NOTE: The motorized reconnecting system
is only adequate for use with RCCBs of the
following series : Series BP, BD, FP, AEG FI.
Do not use for reconnecting circuit breakers
with overload and/or short-circuit
protection. It may result in damage
to the breaker or the installation!

Approach devices ensuring the RCCB


toggle slides into the toggle actuator.

Press devices together until xing clips


click in place.

6.

Inspect both clips to ensure correct


xation.

10

Tele REC
Specially designed for photovoltaic applications
Series Tele REC SOLAR
Reconnection relay
Reconnection relay

Cat. No.

Ref. No.

Pack.

Tele REC SOLAR Motor

677133

The reconnection relay Tele REC SOLAR can be easily coupled to MCBs series EP100 UC:
MCBs Series EP100 UC - B curve
2P
2 mod.

Electrical diagram

In (A)

Cat. No.

Ref. No.

Pack.

6
10
16
20
25
32
40
50
63

EP102UCB06
EP102UCB10
EP102UCB16
EP121UCB20
EP102UCB25
EP102UCB32
EP102UCB40
EP102UCB50
EP102UCB63

673342
673343
673344
673345
673346
673347
673348
673349
673350

6
6
6
6
6
6
6
6
6

Tele REC SOLAR

In (A)

Only valid for photovoltaic application with MCBs


Series EP102UC till 440Vdc (Icc<2ln).
The TELE REC SOLAR voltage is 230Vac.

Manual re-closing
with push-button

REC SOLAR

I : automatic operation
Manual switch (yellow lever)
O : self-reclosing not allowed

=
11

44108

Tele REC

2.

Place the reconnection relay on a at surface and lock relay in OFF position using
the yellow sliding lever.

Install the toggle actuator in the relay.

3.

4.

5.

Ensure that the MCB EP 102UC is OFF. Align


relay and MCB. Check the make and model
of MCB.
NOTE: The motorized reconnecting system is
only adequate for use with MCBS EP 102UC.
Do not use for reconnecting circuit breakers with overload and/or short-circuit
protection. It may result in damage to the
breaker or the installation!

Approach devices ensuring the MCB toggle


slides into the toggle actuator.

Press devices together until xing clips


click in place.

6.

www.ge.com/ex/powerprotection
www.ge.com/eu/powerprotection

Inspect both clips to ensure correct xation.

GE imagination at work

GE CONSUMER & INDUSTRIAL


POWER PROTECTION
Nieuwevaart 51
B-9000 Gent - Belgium
Tel. +32/9 265 21 11
Fax +32/9 265 28 00
E-mail: gepcbel@gepc.ge.com

GE POWER CONTROLS Ltd


129-135 Camp Road
St Albans
Herts AL1 5HL
United Kingdom
Customer Service
Tel. 0800 587 1251
Fax 0800 587 1239
gepcuk@gepc.ge.com

Copyright GE Power Controls 2008

1.

60816 Ref. R/2299/E/EX 3.0 Ed. 04/08

Tele REC SOLAR

Mounting instructions Tele REC SOLAR

You might also like