Professional Documents
Culture Documents
0 - aspenONE
Version 27.0.0.35
User Name :
Job Code :
Project :
Description :
OLUFEMI
Network
Name
Location
Upstream
Node
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
Connector1
Tee1
ReliefValve1
ControlValve1
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Page 1 of 5
Downstream
Node
FLARE TIP
Connector1
Tee1
Tee1
Ignored
Tailpipe
No
No
No
No
Yes
No
Yes
No
Length
(m)
20.000
100.000
0.000
20.000
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Elevation
Change
(m)
20.000
0.000
0.000
0.000
Material
Stainless Steel
Carbon Steel
Carbon Steel
Carbon Steel
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Roughness
(mm)
0.02540
0.04572
0.04572
0.04572
Page 2 of 5
Network
Thermal
Conductivity
(W/m-K)
16.29
51.91
51.91
51.91
Nominal
Diameter
Schedule
Internal
Diameter
(mm)
16 inch
16 inch
16 inch
16 inch
5S
40
40
40
398.018
381.000
381.000
381.000
Wall
Thickness
(mm)
4.191
12.700
12.700
12.700
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Pipe
Class
Sizeable
No
No
No
No
Yes
Yes
Yes
Yes
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Length
Multiplier
Fittings
Loss A
Network
Fittings
Loss B
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
Page 3 of 5
0.00
0.00
0.00
0.00
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Insulation
Outlet
Conductivity Temperature
(W/m-K)
(C)
0.040
0.040
0.040
0.040
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Duty
(kJ/hr)
0.000e+000
0.000e+000
0.000e+000
0.000e+000
Page 4 of 5
Network
VLE
Method
Peng Robinson
Peng Robinson
Model Default
Peng Robinson
Horizontal
Pres. Drop
Inclined
Pres. Drop
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Vertical
Pres. Drop
Beggs and Brill Homog
Beggs and Brill Homog
Model Default
Beggs and Brill Homog
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Network
Friction
Damping
Factor
Factor
Two Phase
Elements
Model Default
Model Default
Model Default
Model Default
Page 5 of 5
Name
OLUFEMI
Location
Node Data
Node
Type
Ignored
Connections
FLARE TIP
No
Flare Tip
Connector1
No
Connector
Tee1
No
Tee
Upstream: Pipe1
Branch: Pipe2
Downstream: FLARE HEADER
ReliefValve1
No
Relief Valve
Outlet: Pipe1
ControlValve1
No
Control Valve
Outlet: Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:25 PM
Page 1 of 2
OLUFEMI
Node Data
Calculations
Name
FLARE TIP
Connector1
Tee1
ReliefValve1
MAWP = 10.00000 bar : Flange Diameter = : Number Of Valves = 1 : Orifice Area Per Valve = 7129.032 mm2
Valve Type = Balanced : Fittings Loss Method = : Two Phase Correction = Yes
Incompressible Calculation = Incompressible (Crane) : Compressible Transition = 10.0% : Isothermal Pressure Drop = Yes
ControlValve1
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 2 of 2
Name
Methane
Ethane
Propane
OLUFEMI
ID
Mol. Wt.
16.043
30.070
44.097
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Critical
Temperature
(K)
190.70
305.43
369.90
Page 1 of 3
Component Data
Critical
Critical
Pressure
Volume
(bar)
(m3/kgmole)
46.407
48.839
42.567
0.09900
0.14800
0.20000
Char.
Volume
(m3/kgmole)
0.09939
0.14575
0.20008
Accentric
Factor
0.01150
0.09860
0.15240
SRK Accentric
Factor
0.00740
0.09830
0.15320
Name
Methane
Ethane
Propane
OLUFEMI
Norm. Boiling
Point
(K)
111.63
184.55
231.05
Standard
Density
(kg/m3)
299.39
355.68
506.68
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Watson
Factor
19.563
19.471
14.732
Page 2 of 3
Component Data
Enthalpy
Enthalpy
Term A
Term B
(kJ/kgmole)
(kJ/kgmole/K)
-2.08237e+002
-5.31486e+001
1.74134e+003
3.79349e+001
3.43669e+001
1.74183e+001
Enthalpy
Enthalpy
Term C
Term D
(kJ/kgmole/K^2) (kJ/kgmole/K^3)
-3.42110e-002
-9.73062e-003
9.32250e-002
9.08317e-005
1.27590e-004
1.74838e-005
Name
Methane
Ethane
Propane
OLUFEMI
Enthalpy
Enthalpy
Term E
Term F
(kJ/kgmole/K^4) (kJ/kgmole/K^5)
-5.97560e-008
-1.02032e-007
-2.94205e-008
Entropy
Term
1.38113e-011 1.00000e+000
2.65245e-011 1.00000e+000
7.40547e-012 1.00000e+000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 3 of 3
Component Data
Viscosity
Viscosity
A Term
B Term
-0.00201
0.07231
0.07112
0.02547 HC
0.04698 HC
-0.06538 HC
Type
Name
Default Scenario
Scenario1
Scenario2
Scenario3
OLUFEMI
System
Back Pres.
(bar)
Header
Mach No.
Header
Vap. Vel.
(m/s)
0.3000
0.3000
0.3000
0.3000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Scenario Data
Header
Header
Liq. Vel.
Rho V2
(m/s)
(kg/m/s2)
Header
Noise
(dB)
100.0
100.0
100.0
100.0
Page 1 of 2
Tailpipe
Mach No.
0.5000
0.5000
0.5000
0.5000
Tailpipe
Vap. Vel.
(m/s)
Tailpipe
Liq. Vel.
(m/s)
OLUFEMI
Scenario Data
Name
Default Scenario
Scenario1
Scenario2
Scenario3
Tailpipe
Rho V2
(kg/m/s2)
Tailpipe
Noise
(dB)
100.0
100.0
100.0
100.0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 2 of 2
OLUFEMI
Fittings
Name
Location
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Upstream
Node
Page 1 of 1
Downstream
Node
Fitting List
OLUFEMI
Messages:Problem
No.
Message
1
2
3
4
Inlet Piping Non Recoverable Pressure Drop Violation For Source 'ReliefValve1' (0.000000%) in Scenario 'Default Scenario'
Inlet Piping Non Recoverable Pressure Drop Violation For Source 'ReliefValve1' (0.000000%) in Scenario 'Scenario1'
Inlet Piping Non Recoverable Pressure Drop Violation For Source 'ReliefValve1' (0.000000%) in Scenario 'Scenario2'
Inlet Piping Non Recoverable Pressure Drop Violation For Source 'ReliefValve1' (0.000000%) in Scenario 'Scenario3'
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 1 of 1
OLUFEMI
Messages:Basis
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
Message
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 1 of 2
OLUFEMI
Messages:Basis
No.
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
Message
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 2 of 2
OLUFEMI
Messages:Solver
No.
Message
1
2
3
4
5
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 1 of 1
OLUFEMI
Messages:Sizer
No.
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Message
Page 1 of 1
OLUFEMI
Messages:Loop
No.
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Message
Page 1 of 1
Name
OLUFEMI
Default Scenario
Location
Outlet
Pipe
ReliefValve1
ControlValve1
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 1 of 5
Source Data
Type
Relief Valve
Control Valve
Ignored
No
No
Inlet
Pressure
(bar)
10.89868
10.00000
Inlet Temp.
Spec.
(C)
25.00
25.00
Name
ReliefValve1
ControlValve1
OLUFEMI
Default Scenario
Allowable
Outlet
Backpressure Temperature
(bar)
(C)
4.60795
5.00000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Mass
Flow
(kg/hr)
25.00
25.00
Page 2 of 5
0.0
2935.0
Source Data
Rated Mass
Flow
(kg/hr)
56071.0
Relief Valve
Type
Balanced
Orifice
Area
(mm2)
7129.032
Name
ReliefValve1
ControlValve1
OLUFEMI
Default Scenario
Orifice
Back Pres.
Limit
(bar)
api_Q
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Source Data
Outlet Fittings Inlet Length Inlet Elev.
Loss Method
(m)
Change
(m)
Calculated
Calculated
Page 3 of 5
0.0000
0.00
Inlet Material
12 inch
12 inch
Name
ReliefValve1
ControlValve1
OLUFEMI
Default Scenario
Inlet
Schedule
40
40
Source Data
Inlet Intern.Inlet PipeInlet FittingsInlet Fittings Static Inlet
Diameter Class
Loss A
Loss B
Pres. Drop
(mm)
(bar)
303.2252
303.225
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
No
No
Page 4 of 5
0.000
0.000
0.000
0.000
VLE
Method
Peng Robinson
Peng Robinson
Inlet Temp.
Calc.
(C)
25.00
25.00
Vapour
Fraction
1.000000
1.000000
Name
ReliefValve1
ControlValve1
OLUFEMI
Default Scenario
Enthalpy
(kJ/hr)
Entropy
(kJ/kgmole/K)
11956.51
11956.51
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
233.947
233.947
Energy
(kJ/hr)
Source Data
Composition
Basis
Page 5 of 5
Mol. Wt.
30.0000
30.0000
Methane
0.004983
0.004983
Ethane
0.995017
0.995017
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Default Scenario
Mass
Flow
(kg/hr)
2935.0
2935.0
0.0
2935.0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Molar
Flow
(kgmole/hr)
97.83
97.83
0.00
97.83
Page 1 of 6
0.00256
0.00085
0.00000
0.00017
1.1
0.0
0.0
0.0
1.01695
1.01704
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Default Scenario
Upstream
Static Pressure
(bar)
1.01581
1.01664
1.01695
1.01704
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Upstream
Temperature
(C)
24.99
24.99
24.99
24.99
Page 2 of 6
0.017
0.018
0.000
0.018
35
41
0
41
1.170e+006
1.170e+006
1.196e-004
1.170e+006
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Default Scenario
Downstream
Static Pressure
(bar)
1.01325
1.01578
1.01695
1.01686
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Downstream
Temperature
(C)
25.00
25.00
25.00
25.00
Page 3 of 6
0.017
0.018
0.000
0.018
35
41
0
41
1.170e+006
1.170e+006
1.196e-004
1.170e+006
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Default Scenario
Flow
Regime
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 4 of 6
0.00013
0.00085
0.00000
0.00017
0.00000
0.00000
0.00000
0.00000
0.00243
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.01538
0.01577
0.00000
0.01577
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Default Scenario
Reynolds
Number
272354
284518
0
284518
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Duty
(kJ/hr)
0.000e+000
0.000e+000
0.000e+000
0.000e+000
Page 5 of 6
Name
OLUFEMI
Default Scenario
Wall
Temperature
(C)
External
Temperature
(C)
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 6 of 6
20.000
100.000
0.000
20.000
Name
OLUFEMI
Scenario1
Location
Outlet
Pipe
ReliefValve1
ControlValve1
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Page 1 of 5
Source Data
Type
Relief Valve
Control Valve
Ignored
No
No
Inlet
Pressure
(bar)
10.89868
10.00000
Inlet Temp.
Spec.
(C)
25.00
25.00
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario1
Allowable
Outlet
Backpressure Temperature
(bar)
(C)
4.60795
5.00000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Mass
Flow
(kg/hr)
25.00
25.00
Page 2 of 5
2935.0
0.0
Source Data
Rated Mass
Flow
(kg/hr)
56071.0
Relief Valve
Type
Balanced
Orifice
Area
(mm2)
7129.032
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario1
Orifice
Back Pres.
Limit
(bar)
api_Q
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Source Data
Outlet Fittings Inlet Length Inlet Elev.
Loss Method
(m)
Change
(m)
Calculated
Calculated
Page 3 of 5
0.0000
0.00
Inlet Material
12 inch
12 inch
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario1
Inlet
Schedule
40
40
Source Data
Inlet Intern.Inlet PipeInlet FittingsInlet Fittings Static Inlet
Diameter Class
Loss A
Loss B
Pres. Drop
(mm)
(bar)
303.2252
303.225
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
No
No
Page 4 of 5
0.000
0.000
0.000
0.000
VLE
Method
Peng Robinson
Peng Robinson
Inlet Temp.
Calc.
(C)
25.00
25.00
Vapour
Fraction
1.000000
1.000000
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario1
Enthalpy
(kJ/hr)
Entropy
(kJ/kgmole/K)
11956.51
11956.51
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
233.947
233.947
Energy
(kJ/hr)
Source Data
Composition
Basis
Page 5 of 5
Mol. Wt.
30.0000
30.0000
Methane
0.004983
0.004983
Ethane
0.995017
0.995017
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario1
Mass
Flow
(kg/hr)
2935.0
2935.0
2935.0
0.0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Molar
Flow
(kgmole/hr)
97.83
97.83
97.83
0.00
Page 1 of 6
0.00256
0.00085
0.00000
0.00000
1.1
0.0
0.0
0.0
1.01668
1.01672
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario1
Upstream
Static Pressure
(bar)
1.01581
1.01664
1.01668
1.01672
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Upstream
Temperature
(C)
24.99
24.99
24.99
24.99
Page 2 of 6
0.017
0.018
0.018
0.000
35
41
41
0
1.170e+006
1.170e+006
1.170e+006
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario1
Downstream
Static Pressure
(bar)
1.01325
1.01578
1.01668
1.01672
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:26 PM
Downstream
Temperature
(C)
25.00
25.00
25.00
25.00
Page 3 of 6
0.017
0.018
0.018
0.000
35
41
41
0
1.170e+006
1.170e+006
1.170e+006
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario1
Flow
Regime
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 4 of 6
0.00013
0.00085
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00243
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.01538
0.01577
4.00228
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario1
Reynolds
Number
272354
284518
284518
0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Duty
(kJ/hr)
0.000e+000
0.000e+000
0.000e+000
0.000e+000
Page 5 of 6
Name
OLUFEMI
Scenario1
Wall
Temperature
(C)
External
Temperature
(C)
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 6 of 6
20.000
100.000
0.000
20.000
Name
OLUFEMI
Scenario2
Location
Outlet
Pipe
ReliefValve1
ControlValve1
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 1 of 5
Source Data
Type
Relief Valve
Control Valve
Ignored
No
No
Inlet
Pressure
(bar)
10.89868
10.00000
Inlet Temp.
Spec.
(C)
25.00
25.00
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario2
Allowable
Outlet
Backpressure Temperature
(bar)
(C)
4.60795
5.00000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Mass
Flow
(kg/hr)
25.00
25.00
Page 2 of 5
2935.0
0.0
Source Data
Rated Mass
Flow
(kg/hr)
56071.0
Relief Valve
Type
Balanced
Orifice
Area
(mm2)
7129.032
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario2
Orifice
Back Pres.
Limit
(bar)
api_Q
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Source Data
Outlet Fittings Inlet Length Inlet Elev.
Loss Method
(m)
Change
(m)
Calculated
Calculated
Page 3 of 5
0.0000
0.00
Inlet Material
12 inch
12 inch
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario2
Inlet
Schedule
40
40
Source Data
Inlet Intern.Inlet PipeInlet FittingsInlet Fittings Static Inlet
Diameter Class
Loss A
Loss B
Pres. Drop
(mm)
(bar)
303.2252
303.225
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
No
No
Page 4 of 5
0.000
0.000
0.000
0.000
VLE
Method
Peng Robinson
Peng Robinson
Inlet Temp.
Calc.
(C)
25.00
25.00
Vapour
Fraction
1.000000
1.000000
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario2
Enthalpy
(kJ/hr)
Entropy
(kJ/kgmole/K)
11956.51
11956.51
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
233.947
233.947
Energy
(kJ/hr)
Source Data
Composition
Basis
Page 5 of 5
Mol. Wt.
30.0000
30.0000
Methane
0.004983
0.004983
Ethane
0.995017
0.995017
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario2
Mass
Flow
(kg/hr)
2935.0
2935.0
2935.0
0.0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Molar
Flow
(kgmole/hr)
97.83
97.83
97.83
0.00
Page 1 of 6
0.00256
0.00085
0.00000
0.00000
1.1
0.0
0.0
0.0
1.01668
1.01672
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario2
Upstream
Static Pressure
(bar)
1.01581
1.01664
1.01668
1.01672
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Upstream
Temperature
(C)
24.99
24.99
24.99
24.99
Page 2 of 6
0.017
0.018
0.018
0.000
35
41
41
0
1.170e+006
1.170e+006
1.170e+006
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario2
Downstream
Static Pressure
(bar)
1.01325
1.01578
1.01668
1.01672
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Downstream
Temperature
(C)
25.00
25.00
25.00
25.00
Page 3 of 6
0.017
0.018
0.018
0.000
35
41
41
0
1.170e+006
1.170e+006
1.170e+006
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario2
Flow
Regime
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 4 of 6
0.00013
0.00085
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00243
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.01538
0.01577
4.00228
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario2
Reynolds
Number
272354
284518
284518
0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Duty
(kJ/hr)
0.000e+000
0.000e+000
0.000e+000
0.000e+000
Page 5 of 6
Name
OLUFEMI
Scenario2
Wall
Temperature
(C)
External
Temperature
(C)
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 6 of 6
20.000
100.000
0.000
20.000
Name
OLUFEMI
Scenario3
Location
Outlet
Pipe
ReliefValve1
ControlValve1
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 1 of 5
Source Data
Type
Relief Valve
Control Valve
Ignored
No
No
Inlet
Pressure
(bar)
10.89868
10.00000
Inlet Temp.
Spec.
(C)
25.00
25.00
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario3
Allowable
Outlet
Backpressure Temperature
(bar)
(C)
4.60795
5.00000
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Mass
Flow
(kg/hr)
25.00
25.00
Page 2 of 5
2000.0
0.0
Source Data
Rated Mass
Flow
(kg/hr)
56071.0
Relief Valve
Type
Balanced
Orifice
Area
(mm2)
7129.032
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario3
Orifice
Back Pres.
Limit
(bar)
api_Q
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Source Data
Outlet Fittings Inlet Length Inlet Elev.
Loss Method
(m)
Change
(m)
Calculated
Calculated
Page 3 of 5
0.0000
0.00
Inlet Material
12 inch
12 inch
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario3
Inlet
Schedule
40
40
Source Data
Inlet Intern.Inlet PipeInlet FittingsInlet Fittings Static Inlet
Diameter Class
Loss A
Loss B
Pres. Drop
(mm)
(bar)
303.2252
303.225
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
No
No
Page 4 of 5
0.000
0.000
0.000
0.000
VLE
Method
Peng Robinson
Peng Robinson
Inlet Temp.
Calc.
(C)
25.00
25.00
Vapour
Fraction
1.000000
1.000000
Name
ReliefValve1
ControlValve1
OLUFEMI
Scenario3
Enthalpy
(kJ/hr)
Entropy
(kJ/kgmole/K)
11956.51
11956.51
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
233.947
233.947
Energy
(kJ/hr)
Source Data
Composition
Basis
Page 5 of 5
Mol. Wt.
30.0000
30.0000
Methane
0.004983
0.004983
Ethane
0.995017
0.995017
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario3
Mass
Flow
(kg/hr)
2000.0
2000.0
2000.0
0.0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Molar
Flow
(kgmole/hr)
66.67
66.67
66.67
0.00
Page 1 of 6
0.00249
0.00042
0.00000
0.00000
0.0
0.0
0.0
0.0
1.01617
1.01619
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario3
Upstream
Static Pressure
(bar)
1.01574
1.01615
1.01617
1.01619
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Upstream
Temperature
(C)
24.99
24.99
24.99
24.99
Page 2 of 6
0.012
0.013
0.013
0.000
16
19
19
0
7.971e+005
7.971e+005
7.971e+005
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario3
Downstream
Static Pressure
(bar)
1.01325
1.01573
1.01617
1.01619
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Downstream
Temperature
(C)
25.00
25.00
25.00
25.00
Page 3 of 6
0.012
0.013
0.013
0.000
16
19
19
0
7.971e+005
7.971e+005
7.971e+005
1.196e-004
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario3
Flow
Regime
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
Single Phase/Single Phase
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 4 of 6
0.00007
0.00042
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00243
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.01640
0.01669
4.00228
Name
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
OLUFEMI
Scenario3
Reynolds
Number
185590
193880
193880
0
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Duty
(kJ/hr)
0.000e+000
0.000e+000
0.000e+000
0.000e+000
Page 5 of 6
Name
OLUFEMI
Scenario3
Wall
Temperature
(C)
External
Temperature
(C)
FLARE STACK
FLARE HEADER
Pipe1
Pipe2
C:\ProgramData\AspenTech\FEMI TRIAL.fnwx
Printed At 8/21/2014 6:23:27 PM
Page 6 of 6
20.000
100.000
0.000
20.000