UL 489 LISTED
The new FUJI UL489 Molded Case Circuit Breaker and Earth Leakage
Circuit Breaker (GLOBAL TWIN series) provide the ultimate in compact
design, unprecedented value, and use anywhere in the world.
50A Frame
125A Frame
250A Frame
400A Frame
Table of Contents
Page
Specifications for MCCB
10
Characteristic Curves
11
Dimensions
14
Internal Accessories
20
External Accessories
27
29
33
34
37
42
100
50
Type
BW50RAGU-2P
BW50RAGU-3P
BW100EAGU-2P
BW100EAGU-3P
Appearance
(with Screw Terminals, 3 poles)
AC
690
690
690
690
DC
AC
240
240
240
240
3,5
Poles
Rated frequency (Hz)
50/60
50/60
50/60
50/60
600V/
600V/Y
480V/
480V/Y
240V
14
14
14
14
DC
250V
AC
690V
600V
5/3
5/3
5/3
5/3
500V
7.5/4
7.5/4
7.5/4
7.5/4
440V
10/5
10/5
10/5
10/5
400V
10/5
10/5
10/5
10/5
230V
25/13
25/13
25/13
25/13
DC
250V
5/3
5/3
5/3
5/3
AC
400V
7/4
10/5
10/5
230V
14/7 25/13
14/7 25/13
25/13
25/13
1.969(50)
2.953(75)
1.969(50)
2.953(75)
4.724(120)
4.724(120)
4.724(120)
4.724(120)
2.362(60)
2.362(60)
2.362(60)
2.362(60)
3.307(84)
3.307(84)
3.307(84)
3.307(84)
None
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
IEC60947-2
JIS C 8201-2-1
lcu/Ics
GB14048.2
Icu/Ics
Dimension
inch (mm)
AC
d
c
b
10,15,20,30,32,40,50
60,63,70,75,80,90,100
10/5
3,5
7/4
10,15,20,30,32,40,50
10/5
SF
Lug terminals
SB
Auxiliary switch
Internal
accessories Auxiliary switch for low current
*4
Alarm switch
BZ6WR10CU
BZ6W*10CU
BZ6WR10CU
BZ6W*10CU
WD
BZ6WDR10CU
BZ6WD*10CU
BZ6WDR10CU
BZ6WD*10CU
BZ6KR10CU
BZ6K*10CU
BZ6KR10CU
BZ6K*10CU
KD
BZ6KDR10CU
BZ6KD*10CU
BZ6KDR10CU
BZ6KD*10CU
WK
BZ6WKR10CU
BZ6WK*10CU
BZ6WKR10CU
BZ6WK*10CU
WDKD
BZ6WDKDR10CU
BZ6WDKD*10CU
BZ6WDKDR10CU
BZ6WDKD*10CU
Shunt trip
BZ6F*10CU
BZ6F*10CU
BZ6F*10CU
BZ6F*10CU
BZ6R*10CAU
BZ6R*10CU
BZ6R*10CAU
BZ6R*10CU
*1
*1
*1
*1
BZ6L10CA
BZ6L10CA
BZ6L10CA
BZ6L10CA
BZ6L10C
BZ6L10C
BZ6L10C
BZ6L10C
BZ6V10D
BZ6V10D
BZ6V10D
BZ6V10D
BZ6N10D
BZ6N10D
BZ6N10D
BZ6N10D
Screw terminals
Terminal
construction Flat terminals
BZ-SU20B
BZ-SU20B
BZ-SU25B
BZ-SU25B
Terminal covers
*3
Provided
Provided
Provided
Provided
BW9BTAA-L2W
BW9BTAA-L3W
BW9BTAA-L3W
BW9BTAA-L3W
BZ6B10C
BZ6B10C
BZ6B10C
BZ6B10C
0.88(0.4)
1.10(0.5)
0.88(0.4)
1.10(0.5)
Insulation barrier *2
Mass: lb. (kg) (screw terminals)
*1 For internal accessories with terminal block, specify "A" in the accessory P/N. When 50A Frame & 100A Frame are ordered w/UVT, the UVT is supplied with terminal block as standard.
*2 Insulation barriers are only required with flat terminal.
*3 Short terminal covers are supplied as standard. If long terminal covers are required, please order BW9BTAA-L2W or BW9BTAA-L3W.
*4 These internal accessories can be installed in the field. (see page 20 for part number)
*5 Non-UL item
: Not available
: Available,
125
Type
BW125JAGU
BW125RAGU
BW250EAGU
BW250JAGU
BW250RAGU
250
Appearance
(with Screw Terminals, 3 poles)
AC
690
690
690
690
690
DC
250
250
250
250
250
AC
600Y/347
600Y/347
240
600Y/347
600Y/347
15,20,30,40,50,60,70,75,80,90,100,125
Poles
Rated frequency (Hz)
50/60
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
GB14048.2
Icu/Ics
Dimension
inch (mm)
50/60
50/60
50/60
50/60
600V/
600V/Y
10
10
18
10
25
480V/
30
50
30
50
480V/Y
30
30
50
30
50
240V
50
50
100
22
50
100
DC
250V
10
10
10
10
10
10
AC
690V
5/3
5/3
500V
15/8
36/18
10/5
18/9
36/18
440V
30/15
50/25
18/9
30/15
50/25
400V
30/15
50/25
18/9
30/15
50/25
380V
30/15
50/25
18/9
30/15
50/25
240V
50/25
100/50
36/18
50/25
100/50
DC
250V
15/8
40/20
10/5
20/10
40/20
AC
400V
30/15
50/25
18/9
30/15
50/25
230V
50/25
100/50
36/18
50/25
100/50
2.362(60)
3.543(90)
4.134(105)
4.134(105)
4.134(105)
6.372(171)
6.372(171)
7.126(181)
7.126(181)
7.126(181)
2.677(68)
2.677(68)
2.677(68)
2.677(68)
2.677(68)
3.740(95)
3.740(95)
3.740(95)
3.740(95)
3.740(95)
None
AC
IEC60947-2
JIS C 8201-2-1
lcu/Ics
125,150,160,175,200,225,250
d
c
b
3.543(90)
Lug terminals
SB
Auxiliary switch
Internal
accessories Auxiliary switch for low current
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
Alarm switch
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
WK
BW9WKSG0(-R)
BW9WKSG0(-R)
BW9WKSG0(-R)
BW9WKSG0(-R)
BW9WKSG0(-R)
18
BW9WKDG0(-R)
BW9WKDG0(-R)
BW9WKDG0(-R)
BW9WKDG0(-R)
BW9WKDG0(-R)
Shunt trip
BW9F*G0
BW9F*G0
BW9F*G0
BW9F*G0
BW9F*G0
BW9RGA*
BW9RGA*
BW9RGA*
BW9RGA*
See page 22
See page 22
See page 22
See page 22
See page 22
Q1
BW9Q1CA
BW9Q1CA
BW9Q1CA
BW9Q1CA
BW9Q1CA
Q2
BW9Q2CA
BW9Q2CA
BW9Q2GA
BW9Q2GA
BW9Q2GA
BW9V0CA
BW9V0CA
BW9V0GA
BW9V0GA
BW9V0GA
BW9N0CA
BW9N0CA
BW9N0GA
BW9N0GA
BW9N0GA
BW9F0GA
BW9F0GA
BW9F0GA
Padlocking device *2
External
accessories
External operating handle
SF
BW9RGA*
Field Installable
terminal kit
BW9F0CA BW9F0CA
BZ-S50B-2253 GLOBAL
BW9SL0CA-3 GLOBAL
Terminal covers
*1
Short type,gray-white
Provided
Short type,transparent
BW9BTCA-S2
Long type,gray-white
Long type,transparent
Insulation barrier
Mass: lb. (kg) (screw terminals)
BW9SS0CA-3 GLOBAL
Provided
Provided
Provided
Provided
BW9BTCA-S3
BW9BTGA-S3
BW9BTGA-S3
BW9BTGA-S3
BW9BTCA-L2W BW9BTCA-L3W
BW9BTCA-L3W
BW9BTGA-L3W
BW9BTGA-L3W
BW9BTGA-L3W
BW9BTCA-L2
BW9BTCA-L3
BW9BTGA-L3
BW9BTGA-L3
BW9BTGA-L3
BW9BPCA
BW9BPGA
BW9BPGA
BW9BPGA
BW9BTCA-S3
BW9BTCA-L3
BW9BPCA
1.76(0.8)
2.65(1.2)
2.20(1.0)
2.65(1.2)
3.09(1.4)
3.53(1.6)
3.09(1.4)
3.53(1.6)
3.09(1.4)
3.53(1.6)
: Not available
400
Type
BW400EAGU
BW400SAGU
BW400RAGU
BW400HAGU
Appearance
(with Flat Terminals, 3 poles)
AC
690
690
690
690
DC
250
250
250
250
AC
240
480
480
600
Poles
Rated frequency (Hz)
50/60
50/60
50/60
50/60
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
600V/
25
25
480V/
35
50
480V/Y
35
50
240V
22
50
100
125
DC
250V
10
10
10
10
AC
690V
10/5
15/8
15/8
500V
18/9
20/11
36/18
42/21
440V
30/15
36/18
50/25
70/35
400V
30/15
36/18
50/25
70/35
380V
30/15
36/18
50/25
70/35
240V
50/25
85/43
100/50
125/63
DC
250V
20/10
20/10
40/20
40/20
AC
400V
30/15
36/18
50/25
70/35
230V
50/25
85/43
100/50
125/63
5.512(140)
5.512(140)
5.512(140)
5.512(140)
10.12(257)
10.12(257)
10.12(257)
10.12(257)
4.055(103)
4.055(103)
4.055(103)
4.055(103)
5.748(146)
5.748(146)
5.748(146)
5.748(146)
None
SB
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
Alarm switch
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
Shunt trip
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
See page 22
See page 22
See page 22
See page 22
QN
BW9QNHA
BW9QNHA
BW9QNHA
BW9QNHA
Q2
BW9Q2HA
BW9Q2HA
BW9Q2HA
BW9Q2HA
BW9V0HA
BW9V0HA
BW9V0HA
BW9V0HA
BW9N0HA
BW9N0HA
BW9N0HA
BW9N0HA
BW9F0HA
BW9F0HA
BW9F0HA
BW9F0HA
BW9BTHA-S3W
BW9BTHA-S3W
BW9BTHA-S3W
BW9BTHA-S3W
BW9BTHA-S3
BW9BTHA-S3
BW9BTHA-S3
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3
BW9BTHA-L3
BW9BTHA-L3
BW9BTHA-L3
B-43A
B-43A
B-43A
GB14048.2
Icu/Ics
Dimension
inch (mm)
d
c
b
Screw terminals
Terminal
construction Flat terminals (standard)
Lug terminals
Auxiliary switch
Internal
accessories Auxiliary switch 2 contacts
Padlocking device *2
External
accessories
External operating handle
Insulation barrier
Mass: lb. (kg) (screw terminals)
*1 Terminal covers are NOT supplied as standard.
*2 Non-UL item
600V/Y
AC
IEC60947-2
JIS C 8201-2-1
lcu/Ics
: Available,
: Not available
10.14(4.6)
12.35(5.6)
10.14(4.6)
12.35(5.6)
10.14(4.6)
B-43A
12.35(5.6)
10.14(4.6)
12.35(5.6)
630
Type
BW630RAGU
BW630HAGU
BW800RAGU
BW800HAGU
800
Appearance
(with Flat Terminals, 3 poles)
AC
690
690
690
690
DC
250
250
250
250
AC
480
600
480
600
Poles
Rated frequency (Hz)
50/60
50/60
50/60
50/60
600V/
25
25
600V/Y
25
25
480V/
50
50
480V/Y
50
50
240V
100
100
100
125
DC
250V
10
10
10
10
AC
690V
15/8
15/8
15/8
15/8
500V
36/18
42/21
36/18
42/21
440V
50/25
70/35
50/25
70/35
400V
50/25
70/35
50/25
70/35
380V
50/25
70/35
50/25
70/35
240V
100/50
125/63
100/50
125/63
DC
250V
40/20
40/20
40/20
40/20
AC
400V
50/25
70/35
50/25
70/35
230V
100/50
125/63
100/50
125/63
8.268(210)
8.268(210)
8.268(210)
8.268(210)
10.83(275)
10.83(275)
10.83(275)
10.83(275)
4.055(103)
4.055(103)
4.055(103)
4.055(103)
5.748(146)
5.748(146)
5.748(146)
5.748(146)
None
*1
*2
*2
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
IEC60947-2
JIS C 8201-2-1
lcu/Ics
GB14048.2
Icu/Ics
Dimension
inch (mm)
AC
d
c
b
Screw terminals
Terminal
construction Flat terminals
700, 800
Lug terminals
SB
*1
Auxiliary switch
Internal
accessories Auxiliary switch 2 contacts
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
Alarm switch
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
Shunt trip
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
See page 22
See page 22
See page 22
See page 22
QN
BW9QNHA
BW9QNHA
BW9QNHA
BW9QNHA
Q2
BW9Q2JA
BW9Q2JA
BW9Q2JA
BW9Q2JA
BW9V0JA
BW9V0JA
BW9V0JA
BW9V0JA
BW9N0JA
BW9N0JA
BW9N0JA
BW9N0JA
BW9BTJA-L3W
BW9BTJA-L3W
BW9BTJA-L3W
BW9BTJA-L3W
BW9BTJA-L3
BW9BTJA-L3
BW9BTJA-L3
BW9BTJA-L3
B-43A
B-43A
B-43A
B-43A
19.62(8.9)
19.62(8.9)
20.72(9.4)
20.72(9.4)
Padlocking device *4
External
accessories
External operating handle
*3
Insulation barrier
Mass: lb. (kg) (screw terminals)
*1 Lug terminal is NOT available for 630 ampere.
*2 Flat terminal is NOT available for 800 ampere.
*3 Terminal covers are NOT supplied as standard.
*4 Non-UL item
: Available,
: Not available
50
100
Type
EW50RAGU-3P
EW100EAGU-2P
EW100EAGU-3P
UL
240
240
240
IEC
100-230-440
100-230
100-230-440
30, 100/200
Poles
Rated frequency (Hz)
50/60
50/60
50/60
480V/
480V/Y
240V
14
14
14
440V
10/5
10/5
415V
10/5
10/5
380V
10/5
10/5
230V
25/13
10/5
25/13
100V
25/13
10/5
25/13
400V
10/5
7.5/4
10/5
230V
25/13
10/5
25/13
2.953(75)
2.953(75)
2.953(75)
4.724(120)
4.724(120)
4.724(120)
2.362(60)
2.362(60)
2.362(60)
3.307(84)
3.307(84)
3.307(84)
None
SF
SB
BZ6W*10CU
BZ6W*10CU
BZ6W*10CU
BZ6K*10CU
BZ6K*10CU
BZ6K*10CU
BZ6F*10CAU
BZ6F*10CAU
BZ6F*10CAU
BZ6R*10CAU
BZ6R*10CAU
BZ6R*10CAU
*1
*1
*1
BZ6L10CA
BZ6L10CA
BZ6L10CA
BZ6L10C
BZ6L10C
BZ6L10C
BZ6V10D
BZ6V10D
BZ6V10D
N
Flat terminal kit
BZ6N10D
BZ6N10D
BZ6N10D
BZ-SU20B
BZ-SU25B
BZ-SU25B
Provided
Provided
Provided
BW9BTAA-L3W
BW9BTAA-L3W
BW9BTAA-L3W
BZ6B10C
BZ6B10C
BZ6B10C
1.32(0.6)
1.32(0.6)
1.32(0.6)
Appearance
(with Screw Terminals, 3 poles)
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
AC
IEC60947-2
JIS C 8201-2-2
lcu/Ics
AC
AC
GB14048.2
Icu/Ics
Dimension
inch (mm)
d
c
b
Screw terminals
Terminal
construction Flat terminals
Lug terminals
Auxiliary switch
Internal
accessories Alarm switch
*4
Shunt trip
Insulation barrier *2
Mass: lb. (kg) (screw terminals)
*1 For Internal accessories with terminal block, specify A in the accessory P/N. When 50A Frame & 100A Frame are ordered w/UVT, the UVT is supplied with terminal block as standard.
*2 Insulation barriers are only required with flat terminal.
*3 Short terminal covers are supplied as standard. If long terminal covers are required, please order BZ6TB10C2U or BZ6TB10C3U.
*4 These internal accessories can be installed in the field. (see page 20 for part number)
*5 Non-UL item
: Available,
: Not available
125
Type
EW125JAGU
EW125RAGU
EW250JAGU
EW250RAGU
UL
240-480
240-480
240-480
240-480
IEC
100-230-440
100-230-440
100-230-440
100-230-440
250
Appearance
(with Screw Terminals, 3 poles)
15,20,30,40,50,60,75,100,125
30
30
30
30
0.1 or less
0.1 or less
0.1 or less
0.1 or less
100/200/500/1000
100/200/500/1000
100/200/500/1000
100/200/500/1000
0.1/0.4/1/2
0.1/0.4/1/2
0.1/0.4/1/2
0.1/0.4/1/2
0/0.2/0.5/1
0/0.2/0.5/1
0/0.2/0.5/1
0/0.2/0.5/1
50/60
50/60
50/60
50/60
480V/
30
50
30
50
480V/Y
30
50
30
50
240V
50
100
50
100
440V
30/15
50/25
30/15
50/25
415V
30/15
50/25
30/15
50/25
380V
30/15
50/25
30/15
50/25
240V
50/25
100/50
50/25
100/50
100V
50/25
100/50
50/25
100/50
400V
30/15
50/25
30/15
50/25
230V
50/25
100/50
50/25
100/50
3.543(90)
3.543(90)
4.134(105)
4.134(105)
6.372(171)
6.372(171)
7.126(181)
7.126(181)
2.677(68)
2.677(68)
2.677(68)
2.677(68)
3.740(95)
3.740(95)
3.740(95)
3.740(95)
None
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1SG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
BW9W1DG0(-R)
Poles
Rated frequency (Hz)
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
AC
IEC60947-2
JIS C 8201-2-2
lcu/Ics
AC
GB14048.2
Icu/Ics
Dimension
inch (mm)
AC
a
d
c
b
Screw terminals
Terminal
construction Flat terminals
SF
Lug terminals
125,150,160,175,200,225,250
SB
Auxiliary switch
W
Internal
accessories Auxiliary switch for low current 1
Alarm switch
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1SG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
BW9K1DG0(-R)
WK
BW9WKSG0(-R)
BW9WKSG0(-R)
BW9WKSG0(-R)
BW9WKSG0(-R)
18
BW9WKDG0(-R)
BW9WKDG0(-R)
BW9WKDG0(-R)
BW9WKDG0(-R)
Shunt trip
BW9F*G0
BW9F*G0
BW9F*G0
BW9F*G0
BW9RGA*
BW9RGA*
BW9RGA*
BW9RGA*
See page 22
See page 22
See page 22
See page 22
Q1
BW9Q1CA
BW9Q1CA
BW9Q1CA
BWQ1CA
Q2
BW9Q2CA
BW9Q2CA
BW9Q2GA
BW9Q2GA
BW9V0CA
BW9V0CA
BW9V0GA
BW9V0GA
BW9N0CA
BW9N0CA
BW9N0GA
BW9N0GA
BW9F0CA
BW9F0CA
BW9F0GA
BW9F0GA
Padlocking device *3
External
accessories
External operating handle
Field Installable
terminal kit
Terminal covers
*1
Insulation barrier
Mass: lb. (kg) (screw terminals)
BW9SS0CA-3 GLOBAL
BW9SL0CA-3 GLOBAL
Provided
BZ-S50B-2253 GLOBAL
Please see page 28.
Provided
Provided
Provided
BW9BTCA-S3
BW9BTGA-S3
BW9BTGA-S3
BW9BTCA-L3W
BW9BTCA-L3W
BW9BTGA-L3W
BW9BTGA-L3W
BW9BTCA-L3
BW9BTCA-L3
BW9BTGA-L3
BW9BTGA-L3
BW9BPCA
BW9BPCA
BW9BPGA
BW9BPGA
2.65(1.2)
2.65(1.2)
3.53(1.6)
3.53(1.6)
: Not available,
400
Type
EW400SAGU
EW400RAGU
EW400HAGU
EW630RAGU
UL
240-480
240-480
240-480
240-480
IEC
100-230-440
100-230-440
100-230-440
100-230-440
30
30
30
0.1 or less
0.1 or less
0.1 or less
100/200/500/1000
100/200/500/1000
100/200/500/1000
100/200/500/1000
0.1/0.4/1/2
0.1/0.4/1/2
0.1/0.4/1/2
0.1/0.4/1/2
0/0.2/0.5/1
0/0.2/0.5/1
0/0.2/0.5/1
0/0.2/0.5/1
50/60
50/60
50/60
50/60
480V/
35
50
50
480V/Y
35
50
50
240V
50
100
125
100
440V
36/18
50/25
70/35
50/25
415V
36/18
50/25
70/35
50/25
380V
36/18
50/25
70/35
50/25
240V
85/43
100/50
125/63
100/50
100V
85/43
100/50
125/63
100/50
400V
36/18
50/25
70/35
50/25
230V
85/43
100/50
125/63
100/50
5.512(140)
5.512(140)
5.512(140)
8.268(210)
10.12(257)
10.12(257)
10.12(257)
10.83(275)
4.055(103)
4.055(103)
4.055(103)
4.055(103)
5.748(146)
5.748(146)
5.748(146)
5.748(146)
None
*1
630
Appearance
(with Flat Terminals, 3 poles)
Poles
Rated frequency (Hz)
Rated
interrupting
capacity
sym (kA)
UL489
CAN/CSA C22.2
No.5
AC
IEC60947-2
JIS C 8201-2-2
lcu/Ics
AC
GB14048.2
Icu/Ics
Dimension
inch (mm)
AC
a
d
c
b
Screw terminals
Terminal
construction Flat terminals
Lug terminals
SB
Auxiliary switch
Internal
accessories Auxiliary switch, 2 contacts
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W1SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W2SHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W1DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
BW9W2DHA
Alarm switch
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K1SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K2SHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K1DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
BW9K2DHA
Shunt trip
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9FHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
BW9RHA-*
See page 22
See page 22
See page 22
See page 22
QN
BW9QNHA
BW9QNHA
BW9QNHA
BW9QNHA
Q2
BW9Q2HA
BW9Q2HA
BW9Q2HA
BW9Q2HA
BW9V0HA
BW9V0HA
BW9V0HA
BW9V2JA
BW9N0HA
BW9N0HA
BW9N0HA
BW9N0JA
BW9F0HA
BW9F0HA
BW9F0HA
BW9BTHA-S3W
BW9BTHA-S3W
BW9BTHA-S3W
BW9BTHA-S3
BW9BTHA-S3
Padlocking device *3
External
accessories
External operating handle
Field Installable terminal
Terminal covers
*4
Insulation barrier
Mass: lb. (kg) (screw terminals)
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3W
BW9BTHA-L3
BW9BTHA-L3
BW9BTHA-L3
BW9BTHA-L3
B43-A
B43-A
B43-A
B43-A
12.35(5.6)
12.35(5.6)
12.35(5.6)
BW250EAGU - 3P 100 SF
Product category
Number of poles
Rated current (A)
Terminal structure
Code
Line
side
Load
side
None
Screw
Screw
None
Flat
Flat
SB
Lug
Lug
SF
Flat
Flat
BW50RAGU
*1
*1 Lug terminal is Not available for BW630AGU-3P630 (Rated current 630 ampere in BW630).
EW50RAGU
3P
050
SF
Product category
Number of poles
Rated current (A)
Rated sensitive current (mA)
Code
Line side
2 poles 3 poles
30mA
50mA*
100/200mA** changeable
Terminal structure
Code
Line
side
Load
side
None
Screw
Screw
None
Flat
Flat
SB
Lug
Lug
SF
Flat
Flat
EW50RAGU
EW100EAGU
EW125JAGU, EW125RAGU
EW125JAGU, EW250RAGU
*1
*1 Lug terminal is Not available for EW630RAGU-3P630 (Rated current 630 ampere in EW630).
BZ6 *
BW9 *
Follow page 3, 7
(50 - 100AF)
Follow page 4, 5, 6, 8, 9
(125 - 800AF)
10
Characteristic Curves
BW50RAGU, EW50RAGU (Rated current: 5A, 10A, 32A, 40A)
20
10
6
4
Minutes
Max. value
Min. value
1
0.6
0.4
0.1
0.06
0.04
0.02
1 1.5 2
350
300
200
150
10
20
30
40
Minutes
20
Max. value
1
40
1
40
Operating time
Seconds
20
Instantaneous tripping
960% to 1440%
Min. value
1
0.6
0.4
0.2
0.02
1 1.5 2
350
1
0.6
0.4
0.2
150
20
30
40
0.01
50
Minute
10
6
4
20
30
40
50
Instantaneous tripping
800% to 1200%
Min. value
1 1.5 2
350
300
250
200
150
100
50
-10
3 4 5 6 7 8 10 15 20 30 40 5060 80100
Multiple of rated current
10
20
30
40
50
20
10
6
4
2
Max. value
1
40
20
20
Min. value
Operating time
1
40
1
0.6
0.4
Instantaneous tripping
characteristic
500A100A
1 1.5 2
3 4 5 6 78 10 15 20 30 405060 80100
Muitiple of rated current
Second
0.2
Rated current
correction ratio (%)
150
0.1
0.06
0.04
0.02
0.01
10
180
120
60
40
20
180
120
60
40
10
6
4
100
Max. value
0.02
100
Minute
0.1
0.06
0.04
10
250
200
150
50
-10
3 4 5 6 7 8 10 15 20 30 40 5060 80100
Multiple of rated current
10
6
4
250
200
350
300
20
300
50
-10
3 4 5 6 7 8 10 15 20 30 40 5060 80100
Multiple of rated current
1 1.5 2
10
6
4
10
6
4
20
Operating time
Correction ratio (%)
Minutes
Operating time
Seconds
0.01
50
180
120
60
40
10
6
4
Min. value
0.02
100
180
120
60
40
0.1
0.06
0.04
Operating time
1
0.6
0.4
0.1
0.06
0.04
Second
Instantaneous tripping
800% to 1200%
0.2
250
50
-10
3 4 5 6 7 8 10 15 20 30 40 5060 80100
Multiple of rated current
10
6
4
Operating time
Correction ratio (%)
20
Operating time
Correction ratio (%)
Operating time
Seconds
Instantaneous tripping
960% to 1440%
Operating time
Correction ratio (%)
Operating time
Seconds
10
6
4
0.01
Max. value
1
40
20
0.2
11
10
6
4
2
1
40
0.01
20
100
50
-10
10
20
30
40
50
10
6
4
2
Max. value
Min. value
1
0.6
0.4
0.2
0.1
0.06
0.04
0.02
0.01
150
Instantaneous tripping
characteristic
500A100A
1 1.5 2
3 4 5 6 7 8 10 15 20 30 40 506080100
Muitiple of rated current
Rated current
correction ratio (%)
Minutes
180
120
60
40
100
50
-10
10
20
30
40
50
Characteristic Curves
BW125, EW125 (Rated current: 30A)
10
6
4
20
20
Max. total fault
clearing time
Min. value
1
0.6
0.4
10
6
4
Rated current
correction ratio (%)
Instantaneous tripping
characteristic
500A100A
0.1
0.06
0.04
1 1.5 2
100
50
-10
3 4 5 6 7 8 10 15 20 30 40506080100
Muitiple of rated current
10
20
30
40
1
0.6
0.4
1
0.6
0.4
Rated current
correction ratio (%)
150
Instantaneous
tripping
characteristic
10In20%
0.2
0.1
0.06
0.04
1.5 2
Operating time
Operating time
Min. value
3 4 5 6 78 10 15 20
100
10
20
30
40
Min. value
2
1
0.6
0.4
30
40
50
Instantaneous
tripping
characteristic
10In20%
0.2
0.1
0.06
0.04
0.01
50
1.5 2
100
50
10
3 4 5 6 7 8 10 15 20 30 405060 80100
Muitiple of rated current
10
20
30
40
50
BW630, EW630
Minute
180
120
60
40
20
10
6
4
Max. value
10
6
4
0.02
50
-10
30 40 50 60 80 100
BW400, EW400
180
120
60
40
20
10
6
4
Max. value
1
40
1
40
Min. value
Operating time
20
1
0.6
0.4
1 1.5 2
3 4 5 6 78 10 15 20 30 405060 80100
Second
Instantaneous
tripping
characteristic
10In20%
Rated current
correction ratio (%)
150
0.02
0.01
20
Max. value
20
0.1
0.06
0.04
10
Rated current
correction ratio (%)
Minute
Max. value
20
0.2
10
6
4
1
40
10
6
4
50
-10
3 4 5 6 7 8 10 15 20 30 40506080100
Muitiple of rated current
20
1
40
Second
Minute
10
6
4
0.02
0.01
1.5 2
BW250, EW250
20
10
6
4
Second
100
180
120
60
40
Minute
Instantaneous tripping
characteristic
500A100A
0.1
0.06
0.04
180
120
60
40
Operating time
0.2
0.02
0.01
50
Second
150
0.2
0.02
0.01
Operating time
1
40
Max. value
Max. value
10
6
4
Second
10
6
4
1
40
Second
Operating time
20
Rated current
correction ratio (%)
20
100
20
10
6
4
Min. value
1
0.6
0.4
Rated current
correction ratio (%)
Minute
180
120
60
40
Instantaneous
tripping
characteristic
10In20%
0.2
0.1
0.06
0.04
0.02
50
10
10
20
30
40
50
0.01
1.5 2
3 4 5 6 7 8 10 15 20
30 40 5060 80 100
100
50
10
10
20
30
40
50
12
Characteristic Curves
Minute
BW800
180
120
60
40
20
10
6
4
Max. value
1
40
Operating time
20
10
6
4
Min. value
1
0.6
0.4
Operating time
Correction ratio (%)
Second
Instantaneous
tripping
characteristic
8In20%
0.2
0.1
0.06
0.04
0.02
0.01
1.5 2
3 4 5 6 7 8 10 15 20
100
50
10
30 40 5060 80 100
10
20
30
40
50
10
30mA
0.1
0.04
0.01
10
50mA
100/200mA
100/200/500mA
30
100 200
500 1000
3000
10000
1
0.5
Minute
0.2
0.1
1
30
20
10
5
2
1
0.5
0.2
0.1
0.04
0.04
0.02
0.02
0.01
0.01
25 50 100
10
1
30
20
10
Operating time
Operating time
Second
Second
10
60
30
60
30
120
Minute
240
120
13
240
Inertia non-operating
time
25 50 100
Inertia non-operating
time
25 50 100
Inertia non-operating
time
25 50 100
0.669 (17)
Trip button
0.315 (8)
0.327 (8.3)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.307 (84)
3.307 (84)
3.937 (100)
0.945 (24)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.307 (84)
0.386 (9.8)
0.098 (2.5)
1.693 (43)
1.575 (40)
2.008 (51)
ON
1.654 (42)
3.307 (84)
Terminal cover
Mounting hole
3.937 (100)
1.969 (50)
1.575 (40)
1.654 (42)
0.386 (9.8)
Terminal cover
Mounting hole
2 pole
1.969 (50)
3 pole (2 pole)*
0.945 (24)
0.386 (9.8)
1.969 (50)
2.953 (75)
0.386 (9.8)
0.984 (25)
Trip button
0.984 (25)
1.969 (50)
2.008 (51)
2.362 (60)
0.157 (4)
0.315 (8)
3.307 (84)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.307 (84)
3.307 (84)
1.969 (50)
1.575 (40)
1.654 (42)
0.098 (2.5)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.307 (84)
1.969 (50)
0.276 (7)
1.811 (46)
1.693 (43)
ON
Trip button
M5x16
Insulation barrier
0.650 (16.5)
Mounting hole
1.969 (50)
3.937 (100)
3.307 (84)
1.654 (42)
1.969 (50)
1.575 (40)
0.650 (16.5)
0.276 (7)
Insulation barrier
3.937 (100)
3 pole
Mounting hole
0.984 (25)
Trip button
M5x16
0.453 (11.5)
0.453 (11.5)
0.079 (2)
1.024 (26)
0.984 (25)
1.969 (50)
0.315 (8)
1.969 (50)
2.953 (75)
2.008 (51)
0.157 (4)
2.362 (60)
3.307 (84)
M8x22
1.969 (50)
0.984 (25)
Trip button
0.709 (18)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.307 (84)
0.164-32 Tap or
0.197 dia hole (M4 or 5)
Breaker
3.973 (100)
1.969 (50)
3.307 (84)
24
0.098 (2.5)
3.307 (84)
1.969 (50)
0.354 (9)
1.811 (46)
1.693 (43)
ON
Trip button
0.709 (18)
Insulation barrier
0.728 (18.5)
Mounting hole
1.575 (40)
1.969 (50)
3.973 (100)
3.307 (84)
1.654 (42)
1.969 (50)
1.575 (40)
0.728 (18.5)
0.354 (9)
Insulation barrier
1.654 (42)
Mounting hole
2 pole
M8x22
0.157 (4)
1.102 (28)
0.984 (25)
2.362 (60)
1.378 (35)
0.315 (8)
2.953 (75)
1.969 (50)
0.157 (4)
2.008 (51)
2.362 (60)
3.307 (84)
14
3-pole (2-pole)*
Mounting
hole
Mounting
hole
CL
0.866 (22)
CL (M4 or 5)
MCCB
0.315 (8)
1.969 (50)
3.346 (85)
2.362 (60)
3.543 (90)
CL
CL
1.181 (30)
0.138 (3.5)
2.362 (60)
2.205 (56)
2.244 (57)
1.496 (38)
Trip button
1.181 (30)
CL
CL
5.197 (132)
ON
1.969 (50)
4.016 (102)
1.496 (38)
5.315 (135)
6.102 (155)
1.969 (50)
4.016 (102)
6.102 (155)
5.315 (135)
0.315 (8)
MCCB
0.157 (4)
5.197 (132)
0.591 (15)
Trip button
1.969 (50)
2.362 (60)
3-pole (2-pole)
0.866 (22)
0.591 (15)
CL
Panel drilling
2-pole
Insulation barrier
Detachable
0.315 (8)
Insulation barrier
Detachable
1.969 (50)
0.315 (8)
1.969 (50)
CL
2.52 (64)
0.276 (7)
2.677 (68)
3.74 (95)
CL
MCCB
Terminal section
ss
CL
0.669 (17)
ss
CL
R0
(R .078
2)
or
le
0.394 (10)
R0
(R .078
2)
or
le
MCCB
0.335 (8.5)
M8 x 16
0.945 (24)
BW250*U-2P, 3P
3-pole (2-pole)*
Panel drilling
0.315 (8)
3.15 (80)
Insulation barrier
Detachable
CL
Mounting
hole
MCCB
CL
3.15 (80)
0.315 (8)
Trip button
4.961 (126)
CL
2.244
(57)
1.791 (45.5)
1.969 (50)
CL
4.134 (105)
0.276 (7)
2.52 (64)
Terminal section
2.677 (68)
3.74 (95)
1 (25.5)
ss
CL
0.433 (11)
2.756 (70)
3.937 (100)
MCCB
1.378 (35)
0.138 (3.5)
0.413 (10.5)
5.67 (144)
4.016 (102)
6.496 (165)
CL
ON
CL
R0
(R .078
2)
or
le
0.866 (22)
0.591 (15)
0.945 (24)
M8 x 16
15
t<0.236 (6)
0.315 (8)
Insulation barrier
Detachable
4.134 (105)
0.157 (4)
0.157 (4)
3.72 (94.5)
Mounting hole
3.543 (90)
5 (127)
4.016 (102)
0.965 (24.5)
2.362 (60)
1.634 (41.5)
8.465 (215)
CL
0.63 (16)
1.634 (41.5)
4.134 (105)
8.858 (225)
10.118 (257)
2.047 (52)
Panel drilling
1.732 (44)
CL
MCCB
CL
MCCB
R0
.
(R2 078
) or
les
s
3.307 (84)
CL
CL
1.732 (44)
8.465 (215)
5.512 (140)
5.315 (135)
3.465 (88)
5.748 (146)
4.626 (117.5)
4.055 (103)
0.276 dia (7)
3-Pole (2-pole)*
CL
Trip button
0.276 dia hole
(M6 or 7)
0.315 (8)
M12 x 35 bolt
1.732 (44)
0.984 (25)
BW630*U-3P
5.748 (146)
Mounting hole
C
L
3.307 (84)
5 (127)
4.016 (102)
3.543 (90)
2.756 (70)
MCCB
C
L
R
(R2 0.07
)o 8
r le
ss
CL
3.661 (93)
8.071 (205)
3.425 (87)
0.965 (24.5)
9.567 (243)
2.047 (52)
0.276 (7)
Panel drilling
MCCB
3.425 (87)
0.157 (4)
3.72
(94.5)
Insulation barrier
Detachable
10.827 (275)
0.315 (8)
4.134 (105)
1.26 (32)
4.134 (105)
8.268 (210)
0.157 (4)
9.567 (243)
2.756 (70)
1.732 (44)
0.591 (15)
4.626 (117.5)
4.055 (103)
CL
Trip button
0.276 (7)
1.516 (38.5)
16
3.425 (87)
4.134 (105)
Mounting hole
3.307 (84)
3.661 (93)
2.756 (70)
0.315 (8)
MCCB
C
L
CL
4.134 (105)
3.425 (87)
0.315 (8)
1.634 (41.5)
CL
ELCB
ON
CL
2.244 (57)
R0
(R .078
2)
or
les
s
5.197 (132)
1.496 (38)
0.157 (4)
CL
Trip button
CL
Operating time
selection switch
0.315 (8)
3.346 (85)
3.543 (90)
0.138 (3.5)
0.276 (7)
ELCB
CL
1.181 (30)
2.52 (64)
2.677 (68)
3.74 (95)
Terminal section
2.362 (60)
CL
Test button
0.335 (8.5)
Megger
test switch
2.362 (60)
0.591 (15)
1.969 (50)
4.016 (102)
5.315 (135)
Mounting
hole
EL trip
indicating button
Sensitive current
selection switch
0.866 (22)
Panel drilling
Insulation barrier
Detachable
0.315 (8)
1.969 (50)
EW125*U-3P
CL
0.669 (17)
0.394 (10)
t<0.236 (6)
17
CL
8.15(207) or more
Trip button
8.071 (205)
C
L
R
(R2 0.07
)o 8
r le
ss
5 (127)
4.016 (102)
3.543 (90)
0.965 (24.5)
9.567 (243)
10.827 (275)
2.047 (52)
Panel drilling
3.72
(94.5)
0.157 (4)
6.102 (155)
0.315 (8)
1.969 (50)
1.26 (32)
Insulation barrier
Detachable
M8 x 16
0.945 (24)
0.315 (8)
MCCB
min. 3.622(92)
8.268 (210)
5.748 (146)
4.626 (117.5)
4.055 (103)
0.157 (4)
9.567 (243)
2.756 (70)
1.732 (44)
0.591 (15)
Trip button
57
CL
ELCB
4.961 (126)
CL
0.138 (3.5)
2.756 (70)
3.937 (100)
0.276 (7)
4.134 (105)
Terminal section
2.52 (64)
2.677 (68)
3.74 (95)
1 (25.5)
ELCB
ss
CL
1.378 (35)
Test button
Megger
test switch
CL
R0
(R .078
2)
or
le
0.433 (11)
3.15 (80)
0.315 (8)
Operating time
selection switch
0.945 (24)
0.413 (10.5)
1.791 (45.5)
CL
CL
ON
1.969 (50)
0.591 (15)
EL trip
indicating button
Sensitive current
selection switch
5.67 (144)
4.016 (102)
6.496 (165)
0.866 (22)
Mounting hole
CL
0.315 (8)
3.15 (80)
Insulation barrier
Detachable
M8 x 16
EW400*U-3P
3.72 (94.5)
EL trip
indicating button
Sensitive current
selection switch
Operating time
selection switch
2.165 (55)
2.362 (60)
Test button
1.732 (44)
CL
ELCB
CL
ELCB
R0
.
(R2 078
) or
les
3.307 (84)
CL
CL
CL
Panel drilling
8.465 (215)
0.965 (24.5)
3.543 (90)
8.465 (215)
8.858 (225)
0.157 (4)
Mounting hole
2.047 (52)
10.118 (257)
5.748 (146)
4.626 (117.5)
4.055 (103)
5 (127)
4.016 (102)
4.134 (105)
5.315 (135)
3.465 (88)
1.732 (44)
0.157 (4)
Insulation barrier
Detachable
5.512 (140)
CL
4.134 (105)
1.634 (41.5)
0.63 (16)
1.634 (41.5)
Trip button
0.984 (25)
0.315 (8)
M12 x 35 bolt
1.732 (44)
EW630RAGU-3P
5.748 (146)
0.276 (7)
Panel drilling
2.756 (70)
C
L
5 (127)
4.016 (102)
3.543 (90)
2.165 (55)
3.287 (83.5)
8.071 (205)
MCCB
C
L
R
(R2 0.07
)o 8
r le
ss
3.307 (84)
Test button
3.661 (93)
CL
MCCB
0.157 (4)
3.72
(94.5)
9.567 (243)
EL trip
indicating button
Sensitive current
Selection switch
Operating time
Selection switch
0.157 (4)
3.425 (87)
9.567 (243)
2.047 (52)
10.827 (275)
Insulation barrier
Detachable
Mounting hole
CL
Trip button
0.315 (8)
4.134 (105)
1.26 (32)
4.134 (105)
8.268 (210)
4.626 (117.5)
4.055 (103)
2.756 (70)
1.732 (44)
0.965
(24.5)
0.591 (15)
1.516 (38.5)
18
0.5 (12.5)
0.5 (12.5)
0.5 (12.5)
0.5 (12.5)
4.7 (117.5)
4.1 (103)
3.7 (94)
0.75 (19)
1.5 (38)
2-terminal block
WxH
BW50RAGU-2P, BW100EAGU-2P
BW50RAGU-3P, BW100EAGU-3P
EW50RAGU, EW100EAGU
Breaker
Type
Black
Gray-white
BW9BTAA-S2W **
(Short)
Dimensions: Inch(mm)
A
B
C
Applicable Breakers
Transparent
BW9BTAA-S2
(Short)
1.969
(50)
0.386
(9.8)
2.106
(53.5)
BW50RAGU-2P, BW100EAGU-2P
BW9BTAA-L2
(Long)
BW9BTAA-L2W
(Long)
1.969
(50)
1.575
(40)
2.106
(53.5)
BW9BTAA-S3
(Short)
BW9BTAA-S3W**
(Short)
2.953
(75)
0.386
(9.8)
2.106
(53.5)
BW9BTAA-L3
(Long)
BW9BTAA-L3W
(Long)
2.953
(75)
1.575
(40)
2.106
(53.5)
BW9BTCA-S2
(Short)
BW9BTCA-S2W**
(Short)
2.362
(60)
0.315
(8)
2.618
(66.5)
BW9BTCA-L2
(Long)
BW9BTCA-L2W
(Long)
2.362
(60)
1.575
(40)
2.618
(66.5)
BW9BTCA-S3
(Short)
BW9BTCA-S3W**
(Short)
3.543
(90)
0.315
(8)
2.618
(66.5)
BW9BTCA-L3
(Long)
BW9BTCA-L3W
(Long)
3.543
(90)
1.575
(40)
2.618
(66.5)
BW9BTGA-S3
(Short)
BW9BTGA-S3W**
(Short)
4.134
(105)
0.315
(8)
2.618
(66.5)
BW9BTGA-L3
(Long)
BW9BTGA-L3W
(Long)
4.134
(105)
1.969
(50)
2.618
(66.5)
BW9BTHA-S3
(Short)
BW9BTHA-S3W
(Short)
5.512
(140)
2.559
(65)
3.858
(98)
BW9BTHA-L3
(Long)
BW9BTHA-L3W
(Long)
6.772
(172)
4.331
(110)
3.858
(98)
BW9BTJA-L3
(Long)
BW9BTJA-L3W
(Long)
8.268
(210)
6.102
(155)
3.858
(98)
BW50RAGU-3P, BW100EAGU-3P
EW50RAGU-3P, EW100EAGU-2P
EW100EAGU-3P
BW125*U-2P
BW125*U-3P
EW125*U-3P
BW250*U-2P, BW250*U-3P
EW250*U-3P
BW400*U-2P, BW400*U-3P
EW400*U-3P
BW630*U-3P, BW800*U-3P
EW630*U-3P
**A Gray-white terminal cover provied with BW50U, BW100U, BW125U, BW250U, EW100U, EW125U, EW250U amp frame.
19
W
WD
K
KD
WK
WDKD
BW50RAGU, EW50RAGU
BW100EAGU, EW100EAGU
Left side
BZ6WL10CU*1
BZ6WDL10CU*1
BZ6KL10CU*1
BZ6KDL10CU*1
BZ6WKL10CU*1
BZ6WDKDL10CU*1
Aux
Aux low current
Alarm
Alarm low current
Aux & Alarm
Aux & Alarm low current
Right side
BZ6WR10CU
BZ6WDR10CU
BZ6KR10CU
BZ6KDR10CU
BZ6WKR10CU
BZ6WDKDR10CU
Operating voltage
120V AC
240V AC
125V DC
250V DC
Left side
BZ6WL10CAU*1
BZ6WDL10CAU*1
BZ6KL10CAU*1
BZ6KDL10CAU*1
BZ6WKL10CAU*1
BZ6WDKDL10CAU*1
W
WD
K
KD
WK
WDKD
Right side
BZ6WR10CAU
BZ6WDR10CAU
BZ6KR10CAU
BZ6KDR10CAU
BZ6WKR10CAU
BZ6WDKDR10CAU
Rating
Standard; Aux, Alam
Breaker type
BW50RAGU, EW50RAGU
BW100EAGU, EW100EAGU
Minimum load
BW50RAGU, EW50RAGU
BW100EAGU, EW100EAGU
Rated current (A)
3.6
1.8
0.55
0.27
Operating voltage
30V DC
5V DC 160mA
30V DC 30mA
Minimum load
BW50RAGU, EW50RAGU
BW100EAGU, EW100EAGU
Rated current (A)
0.1
5V DC 1mA
30V DC 1mA
Operation
Type of switch
Condition of MCCB
ON
Auxiliary switch
(W)
OFF
11/AXcL
TRIP
11/AXcL
14/AXaL
12/AXbL
Alarm switch
91/ALcL
(K)
14/AXaL
12/AXbL
94/ALaL
91/ALcL
92/ALbL
94/ALaL
92/ALbL
EW50RAGU
EW100EAGU
Operating voltage
Code
24VAC, 24VDC
FR
100-120VAC
100-110VDC
200-240VAC
FA
FK
Part number
Spec
With terminal block type Input (VA) Internal circuit
150
Continuous
BZ6FR10CAU
with burnout
150
prevention
BZ6FA10CU
BZ6FA10CAU
circuit
150
BZ6FK10CU
BZ6FK10CAU
380-450VAC
FP
BZ6FP10CU
100VAC 50Hz
100-110VAC 60Hz
200VAC 50Hz
200-220VAC 60Hz
400VAC 50Hz
400-440VAC 60Hz
F2
Operating voltage
Code
BZ6FP10CAU
200
BZ6F210CAU
16
F7
BZ6F710CAU
16
F8
BZ6F810CAU
22
Continuous
7-13
100VAC 50Hz
100-110VAC 60Hz
200VAC 50Hz
200-220VAC 60Hz
400VAC 50Hz
400-440VAC 60Hz
24VDC
Part number
Spec
With terminal block type Input
BZ6R210CAU
2.8 VA
R2
RW
BZ6RW10CAU
3.4 VA
R9
BZ6R910CAU
4.4 VA
RF
BZ6RF10CAU
40W
Operating voltage
Tripping voltage:
70% to 35% of rated voltage
Closing voltage:
85% or more of rated voltage
20
3P
2P
Right
Left
Handle
Handle
MCCB
Pole
Auxiliary switch: W
Shunt trip: F
Alarm switch: K
Undervoltage trip: R
BW50RAGU-2P
BW100EAGU-2P
BW50RAGU-3P
BW100EAGU-3P
ELCB
EW50RAGU-3P
EW100EAGU-2P
EW100EAGU-3P
Pole
2, 3
Auxiliary switch
SPDT W
Alarm switch
SPDT K
Shunt trip F
Auxiliary switch
SPDT W
Alarm switch
SPDT K
Shunt trip F
Undervoltage
trip R
W2
Right
Undervoltage
trip R
W2
W+K
W2+K
N/A
K2
W+K
W+K2
W2+K
K2
W+K2
W2+K2
W+F
W2+F
N/A
W2+K2
N/A
W+F
N/A
W+R
N/A
W2+R
N/A
N/A
K+F
N/A
K+R
W+R
K2+R
W2+R
K+F
N/A
W+K+F
N/A
W+K+R
K+R
W2+K+R
W+K+F
N/A
W+K2+R
W+K+R
W2+K2+R
K2+F
K2+R
W2+K+F
W2+K+R
W+K2+F
W+K2+R
W2+K2+F
W2+K2+R
21
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
RR BW9RGAR
Undervoltage trip device
RS BW9RGAS
RL BW9RGAL
R5 BW9RGA5
RA BW9RGAA
RT BW9RGAT
RK BW9RGAK
RB BW9RGAB
RP BW9RGAP
RH BW9RGAH
Accessory
Operating voltge
With terminal block type
Left side
Right side
BW9W1SG0-A BW9W1SG0-RA
BW9K1SG0-A BW9K1SG0-RA
BW9WKSG0-A BW9WKSG0-RA
48V DC
100-110V DC
125V DC
100-110V AC
110-130V AC
200-240V AC
277V AC
380-415V AC
440-480V AC
BW9K1SHA-A
BW9FHA-RA
BW9FHA-AA
BW9FHA-BA
BW9FHA-PA
Operating voltge
24-48V AC/DC
100-240V AC/100-220V DC
277V AC
380-550V AC
24V AC/DC
48V AC/DC
100-110 AC/DC
120-130V AC/125V DC
200-240V AC/200-220V DC
277V AC
380-480V AC
22
Handle position
ON
Auxiliary switch
SPDT: W
(1)
2PDT: V
(2)
OFF
11/AXcL
Trip
14/AXaL
11/AXcL
14/AXaL
12/AXbL
11/AXcL
14/AXaL
21/AXcR
24/AXaR
12/AXbL
11/AXcL
14/AXaL
21/AXcR
24/AXaR
12/AXbL
12/AXbL
22/AXbR
22/AXbR
Alarm switch
94/ALaL
91/ALcL
SPDT: K
(8)
91/ALcL
92/ALbL
92/ALbL
2PDT: J
(9)
91/ALcL
94/ALaL
01/ALcR
04/ALaR
91/ALcL
92/ALbL
94ALaL
92/ALbL
01/ALcL
02/ALbR
Note:
94/ALaL
04/ALaL
02/ALbL
Handle position
ON/OFF/Overcurrent trip
L
71
EL trip
71
74
74
72
72
BW125, BW250
BW400
BW630
BW800
EW125, EW250
EW400
EW630
Rated
thermal
current (A)
5
BW125, BW250
BW400
BW630
BW800
EW125, EW250
EW400, EW630
Rated
thermal
current (A)
0.1
Ind. load
5
DC
Voltage
(V)
24
48
125
250
Ind. load
48
2.5
125
0.4
0.4
250
0.2
0.2
23
Res. load
DC
Voltage
(V)
30
Res. Ioad
0.1
Minimum
load current
5V DC
160mA
30V DC
30mA
Minimum
load current
5V DC 1mA
Breaker type
AC
V
VA
DC
V
BW125, BW250
EW125, EW250
24
48
100-120
120-130
200-240
277
380-440
440-480
500-550
24-48
100-240
277
380-550
50
50
50
50
50
50
50
50
50
2
3
3
4
24
48
100-110
200-220
24-48
100-220
50
50
50
50
2
3
Opearting time
(ms)
Continuous
13-21
(With 1NO contact
to prevent coil
burn-out)
Continuous
8-20
Note: Allowable voltage function AC voltage: 85% to 110% of coil rated voltage
DC voltage: 75% to 125% of coil rated voltage
AC
V
VA
DC
V
BW125 *1
BW250 *1
EW125 *1
EW250 *1
100-110
110-130
200-240
277
380-415
440-480
24
48
100-110
120-130
200-240
277
380-480
5
5
5
5
5
5
2
2
3
3
3
3
4
24
48
100-110
125
24
48
100-110
125
200-220
5
5
5
5
2
2
3
3
3
BW400 *2
EW400 *2
BW630 *2
EW630 *2
BW800 *2
Note: Allowable voltage function AC voltage: 85% to 110% of coil rated voltage
DC voltage: 75% to 125% of coil rated voltage
Code
RR
RS
RL
R5
RA
RT
RK
RB
RP
RH
RR
RS
RA
R1
RK
RB
RP
*1 Reset-allowed type: When the breaker handle is in the OFF or RESET state, tripping does not occur even if the R coil is not energized.
Turning ON with the R coil not energized causes normal tripping.
*2 Reset-prohibited type: When the R coil is not energized, reset operation cannot reset the tripped breaker to the OFF state.
24
3-pole
Right
Handle
MCCB
Right
Left
Undervoltage trip: R
Shunt trip: F
Auxiliary switch: W
Alarm switch: K
Handle
BW125JAGU-2P
BW125
BW250
(Except for BW125JAGU-2P)
Pole
2, 3
BW400
BW630
BW800
2, 3
Auxiliary switch
SPDT: W (1)
Alarm switch
SPDT: K (8)
Shunt trip: F
Undervoltage trip: R
W+K (1+8)
Auxiliary switch
2PDT: V (2)
Alarm switch
2PDT: J (9)
V+K (2+8)
W+J (1+9)
V+J (2+9)
W+F (1+F)
W+R (1+R)
K+F (8+F)
K+R (8+R)
W+K+F (1+8+F)
W+K+R (1+8+R)
V+F (2+F)
V+R (2+R)
J+F (9+F)
J+R (9+R)
V+K+F (2+8+F)
V+K+R (2+8+R)
W+J+F (1+9+F)
W+J+R (1+9+R)
V+J+F (2+9+F)
V+J+R (2+9+R)
Notes: The above table is applied to front mounting type, rear mounting type, flush mounting type, and plug-in mounting type.
Terminal block is attached on the same side of the accessory.
( ) Code of low level circuit
25
3-pole
Right
Handle
Right
Left
Undervoltage trip: R
Shunt trip: F
Auxiliary switch: W
Alarm switch: K
Handle
ELCB
EW125
EW250
EW400
EW630
Pole
Auxiliary switch
SPDT: W (1)
Alarm switch
SPDT: K (8)
Shunt trip: F
Undervoltage trip: R
W+K (1+8)
Auxiliary switch
2PDT: V (2)
Alarm switch
2PDT: J (9)
V+K (2+8)
W+J (1+9)
V+J (2+9)
W+F (1+F)
W+R (1+R)
K+F (8+F)
K+R (8+R)
W+K+F (1+8+F)
W+K+R (1+8+R)
V+F (2+F)
V+R (2+R)
J+F (9+F)
J+R (9+R)
V+K+F (2+8+F)
V+K+R (2+8+R)
W+J+F (1+9+F)
W+J+R (1+9+R)
V+J+F (2+9+F)
V+J+R (2+9+R)
Earth alarm switch
SPDT: L*1
Notes: The above table is applied to front mounting type, rear mounting type, flush mounting type, and plug-in mounting type.
Terminal block is attached on the same side of the accessory.
( ) Code of low level circuit
*1 Earth alarm switch can be mounted regardless of the combination of other accessories.
26
External Accessories
Operating handles
Conforms to EN60947-1 isolation function.
Available for EN60204-1 power breaking device.
Conforms to UL489(File No. E93289)
N type handles
V type handles
Breaker
N type handle on
breaker
Breaker
V type handle on
panel
Decorative plate
BW9N0CA
N type handle
BW9V0CA
V type handle
Applicable Breakers
Part number
N type (Breaker mount)
BZ6N10D
BZ6V10D
BW9N0CA
BW9V0CA
BW125*1, EW125
BW9N0GA
BW9V0GA
BW250, EW250
BW9N0HA
BW9V0HA
BW400, EW400
BW9N0JA
BW9V0JA
* Note that the external operating handle cannot be mounted to the BW125JAGU-2P. Use the BW125RAGU-2P.
1
Terminal covers
These terminal covers are used as guards to prevent
accidental touch with live line terminations.
These terminal covers can be fitted to either line or load side.
Short type
Short type
Black
Transparent
Gray-White
Packing QTY
Applicable Breakers
BW9BTAA-S2
BW9BTAA-S2W*1
BW50RAGU-2P, BW100EAGU-2P
BW9BTAA-S3
BW9BTAA-S3W*1
BW9BTCA-S2
BW9BTCA-S2W*1 2
BW125JAGU-2P
BW9BTCA-S3
BW9BTCA-S3W*1 2
BW125JAGU-3P, EW125*U-3P
BW9BTGA-S3
BW9BTGA-S3W*1 2
BW9BTHA-S3*2
BW9BTHA-S3W*2 2
Notes: *1 Gray-white short type terminal covers are provided with breaker as standard for 50AF, 100AF, 125AF and 250AF G-TWIN breakers.
*2 Not available with Flat terminal.
Long type
Black
Transparent
Gray-White
Packing QTY
Applicable Breakers
BW9BTAA-L2
BW9BTAA-L2W
BW50RAGU-2P, BW100EAGU-2P
BW9BTAA-L3
BW9BRAA-L3W
BW9BTCA-L2
BW9BTCA-L2W
BW125JAGU-2P
BW9BTCA-L3
BW9BTCA-L3W
BW125*U-3P, EW125*U-3P
BW9BTGA-L3
BW9BTGA-L3W
BW9BTHA-L3
BW9BTHA-L3W
BW9BTJA-L3
BW9BTJA-L3W
27
Long type
External Accessories
Insulation barriers
The barriers are installed in the molded slots between terminals.
Installation of these barriers after wiring is possible even when an
external accessory is installed.
Insulation barriers
Type
Applicable Breakers
Packing quantity
BZ6B10C
BW9BPCA
BW125, EW125*2
BW9BPGA
BW250, EW250*2
B-43A
Note: *1 Insulation Barriers are required only for flat terminal type.
*2 Insulation Barriers for line side and load side are provided with the Breaker.
Type
Applicable Breakers
Packing quantity
BZ-SU20B
BW50RAGU, EW50RAGU
BZ-SU25B
BW100EAGU, EW100EAGU
BW9SS0CA-3 GLOBAL
BW9SL0CA-3 GLOBAL
BW125, EW125
BZ-S50B-2253 GLOBAL
BW9SL0GA-3 GLOBAL
BW9SL1GA-3 GLOBAL
Padlocking device
BZ6L10CA
Not available
BW125, EW125
BW9Q1CA
BW9Q2CA
BW250, EW250
BW9Q1CA
BW400, EW400
BW9QNHA*1
BW9Q2HA
Not available
BW9QNHA*1
BW9Q2JA
Not available
Non-UL
BW9Q2GA
Not available
BW9Q1CA
Plate type Q2
BW9Q2GA
28
Operating Handles
MCCB ELCB
Handle
C/L
MCCB ELCB
Handle
C/L
Panel thickness
0.047 to 0.126 (1.2 to 3.2)
LOAD SIDE
1.93 (49)
90
ia (
5d
3.5
3.07 (78)
4.13 (105)
)
15
-
(4
a
i
d
6 Handle
0.
C/L
4-
3.07 (78)
0.9 (23)
0.23 (6)
0.55 (14)
MCCB,ELCB
0.67 (17)
0.1 (2.5)
0.31 (8)
0.63 (16)
0.1 (2.5)
0.47 (12)
0.9 (23)
Breaker type
H: inch(mm)
4.0550.078
(1032)
Handle type
BZ6N10D
BW50RAGU
EW50RAGU
BW100EAGU
EW100EAGU
Mounting screw
#8-323.149
(M480)
3.35 (85)
4.09 (104)
4.33 (110)
7.87 (200)
0.
4-
4.45 (113)
di
Handle
C/L
Breaker
C/L
3.55
2.44 (62)
3.07 (78)
H
Pad lock 0.16 to 0.31 dia (4 to 8)
0.79 (20)
0.79 (20)
2.2 (56)
0)
(9
Panel thickness:
0.047 to 0.126 (1.2 to 3.2)
LOAD SIDE
1.5 (38)
dia
3.07 (78)
MCCB ELCB
handle
C/L
2.2 (56)
4.45 (113)
15
(4
LINE SIDE
X=H-4.13 (105)
2.87 (73)
0.59 (15)
0.59 (15)
2.87 (73)
2.36 (60)
7.87 (200)
7.87 (200)
BW50RAGU
EW50RAGU
BW100EAGU
EW100EAGU
Handle type
BZ6V10D
Standard type
H: inch(mm)
X=6.102(155)
X
= 5.709 (145)
4.1340.078
(1052)
H:inch(mm)
9.8420.078
(2502)
5.590 to 9.842
(142 to 250)
29
Mounting screw
#8-323.149
(M480)
1.41
(0.64)
Operating Handles
3.071 (78)
Thickness:
0.047 to 0.126 (1.2 to 3.2)
H
Note: Align the center of the hole cut in the panel
with the center of the breaker handle.
1.969 (50)
Load
Breaker type
H: inch(mm)
4.0550.078
(1032)
Handle type
BW9N0CA
BW125
EW125
BW250
EW250
1.102
(28)
Mounting screw
#8-323.346
(M485)
Padlock size
0.157 dia to 0.315 dia (4 to 8)
0.157 (4)
90
ia (
3d
4
3.5
7.874 (200)
0.276 (7)
MCCB
Handle
C/L
Handle C/L
MCCB
handle C/LCL
7.874 (200)
1.417
(36)
Handle
C/L
0.827 1.535
(21)
(39)
Panel
MCCB
C
L
4.134 (105)
Line
3.071 (78)
4.252 (108)
2.067 (52.5)
Handle C/L
BW9N0GA
4P 3P
2P
Mounting screw
Line
Panel
4.409(112)
Decorative
plate
Lock plate
Padlock size 0.157 dia (4)
to 0.315 dia (8)
(Up to 2 0.315 dia (8)
padlocks can be mounted.)
3.937 (100)
0.295 (7.5)
2.087 (53)
38)
(1
MCCB
handle C/L
7.874(200)
7.874(200)
1.378 (35)
2.559 (65)
2.559 (65)
1.378 (35)
0.984 (25)
0.591 (15)
3.937 (100)
dia
MCCB
handle C/L
Panel thickness:
0.063-0.126 (1.6-3.2)
Handle C/L
33
5.4
0.984 (25)
Load
4.409 (112)
3.78 (96)
0.669 (17)
5.906 (150)
3.78 (96)
MCCB
handle C/L
15
0.5
4-
ia
1d
Handle type
BW9N0HA
H: inch(mm)
6.1810.078
(1572)
Mounting screw
1/4-204.331
(M6110)
BW9N0JA
30
Operating Handles
C
L
Panel
MCCB
2.677 (68)
Handle
C/L
4.449 (113)
MCCB
handle
C/L
MCCB
Handle C/L
43
3.5
dia
0)
(9
3.071 (78)
4.449 (113)
Line
3.071(78)
Load
Panel thickness:
0.047 to 0.126 (1.2 to 3.2)
2.559 (65)
C
L
1.929 (49)
Handle C/L
4P 3P
2P
0.591 (15)
0.039 (1)
0.315 (8)
1.929 (49)
4.724 (120)
2.362 (60)
1.614
(41)
1.063
(27)
1.063 (27)
2.362 (60)
1.181 (30)
4.724 (120)
Handle type
Standard type
H: inch(mm)
BW125
EW125
BW250
EW250
BW9V0CA*1
4.1340.078
(1052)
BW9V0GA*2
Notes:
The handle cannot hold the enclosure door.
Not available for side mounting.
Handle protection degree is IP 54 (IEC60529,JIS C0920).
*1 Note that the external operating handle cannot be mounted to the BW125JAGU-2P. Use the BW125RAGU-2P.
*2 When mounting a terminal cover, cut away part of it because it hides the mounting screws for the breaker.
Remove the shaded parts in the figure below.
31
Mounting
screw
Mass
lb. (kg)
#8-32x3.346
M4 x 85
1.48
(0.67)
Operating Handles
Line
Panel
4.409 (112)
Decorative
plate
Mounting
screw
Panel thickness: 0.063-0.126 (1.6-3.2)
4.409 (112)
5.906 (150)
5.
8)
13
ia (
d
433
5.906 (150)
OFF
MCCB
handle C/L
2.48(63)
MCCB
handle C/L
MCCB
handle C/L
Note: Align the center of the hole cut in the panel
with the center of the breaker handle.
Load
Lock plate
0.3
4-
10
ia
4d
1.181 (30)
2.165 (55)
0.394 (10)
3.937 (100)
7.874 (200)
Breaker type
Handle type
BW400
EW400
BW630, BW800
EW630
BW9V0HA
Mounting screw
Mass
lb. (kg)
1/4-20X4.331
(M6X110)
4.85
(2.2)
BW9V0JA
32
Wiring
1. Connecting Precautions
When connecting the wires, follow the instruction of NEC (National Electric Code, USA) or CEC (Canadian Electrical code Part 1, Canada).
For connecting, use copper wire rated for 75
C. It is recommended to use UL or CSA approved wires.
Keep the connection of the wire sufficiently tight, because a very large electromagnetic force will be generated, when the short circuit
current is applied.
Perform additional tightening of the terminal screws periodically.
3. Allowable wire spec for Lug Terminals
2. Terminal Construction
Screw Terminals
Flat Terminals
Lug Terminals
14 2 (2.1 33.6)
19
37
: Not available
Caution
Two wires cannot be connected together to a single connecting hole of lug terminal except BW400SAGU-3P400SB.
Follow the number of strands of wire indicated on the table.
(Wire size and number of wire strands not listed on table can not be connected)
Do not solder the end of the wire.
BW100EAGU
EW100EAGU
BW125
EW125
BW250
EW250
BW400
EW400
BW630
EW630
BW800
Rated
Wire size*2
current (A) AWG or MCM (mm2)
3
5
10
15
20
30
40
50
60
75
100
15
20
30
40
50
60
70
75
80
90
100
125
125
150
175
200
225
250
250
300
350
400
14 AWG
(2.1mm2)
14 AWG (2.1mm2)
14 AWG (2.1mm2)
14 AWG (2.1mm2)
12 AWG (3.3mm2)
10 AWG (5.3mm2)
8 AWG (8.4mm2)
8 AWG (8.4mm2)
6 AWG (13.3mm2)
4 AWG (21.1mm2)
3 AWG (26.7mm2)
14 AWG (2.1mm2)
12 AWG (3.3mm2)
10 AWG (5.3mm2)
8 AWG (8.4mm2)
Applicable ring (crimp) terminal for screw type and flat type terminal breaker*1
Tightening torque
Screw terminal
Flat terminal
Lug terminal
20-25 lb.-In
(2.3-2.8 N-m)
31-40 lb.-in.
(3.5-4.5 N-m)
R2-5
NICHIFU
(UL file No.E44245)
DST
(UL file No.E74917)
R2-5M
R2-5
2-S5, 2-5
R5.5-5
R3.5-5S, R3.5-5L
5.5-6N, R5.5-5S,
R5.5-5
R8-5S, R8-5
3.5-5, 5.5-S5,
5.5-5, 5.5-L5
8-S5, 8-5
R14-8S, R14-8
R22-8S, R22-8
R38-8S
R2-8
R3.5-8, R5.5-8
R5.5-8
R8-8
R14-S8, R14-8
R22-S8, 22-8
38-S8
2-8, 2-B8
3.5-8, 5.5-8
5.5-8
8-8
R8-5
49-66 lb.-In
(5.5-7.5 N-m)
71-89 lb.-In
(8-10 N-m)
51 lb. - In.
(5.8 N-m)
51 lb. - In.
(5.8 N-m)
51 lb. - In.
(5.8 N-m)
51 lb. - In.
(5.8 N-m)
R14-8
22-S8
38-S8
R2-8
5.5-S8, R5.5-8
8-8NS, R8-8
6 AWG (13.3mm2)
4 AWG (21.1mm2)
R14-8S, R14-8
14-S8, 14-8
R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8
3 AWG (26.7mm2)
38-S8
R38-8S
38-S8
38-S8, R38-8
60-S8, R60-8
70-8
CB80-S8
CB100-S8
CB150-S8
150-12
180-12
325-12
R80-12
325-12
R150-12
180-12
325-12
325-12
R38-S, R38-8
R60-8, CB60-8, CB60-8S
R70-8
CB150-S8
R150-12
R180-12
R325-12N
R80-12
R325-12N
R150-12
R180-12
R325-12N
R325-12N
38-S8, 38-8
60-8, CB60-8
70-8
CB80-8
CB100-8
CB150-8
-
500
600
630
700
1 AWG (42.4mm2)
1 AWG (42.4mm2)
1/0 AWG (53.5mm2)
2/0 AWG (67.4mm2)
3/0 AWG (85.0mm2)
4/0 AWG (107.2mm2)
250 MCM (127mm2)
250 MCM (127mm2)
350 MCM (177mm2)
500 MCM (253mm2)
3/0 AWG x 2 (85.0mm2 x 2)
500 MCM (253mm2)
250 MCM x 2
350 MCM x 2
500 MCM x 2
500 MCM x 2
800
300 MCM x 3
93 lb. - In.
(10.5 N-m)
93 lb. - In.
(10.5 N-m)
Notes: *1 Ring (Crimp) Terminal Manufacturer : JST=Japan Solderless Terminal MFG Co., Ltd. ( http://www.jst.com )
NICHIFU=Nichifu Terminal Co., Ltd. ( america@nichifu.com )
DST=Daido Solderless Terminal MFG Co., Ltd. ( info@daido-tanshi.jp )
*2 167
F (75
C) Copper wire
33
JST
(UL file No.E42024)
Ordering information
Main unit and cable are minimum required for assembling.
Select cable with main unit using below table.
Ex: BW9F0CA, BW9FWCA-15A
Specifications
Applicable breaker frame size
Part numbers
cover*2
BW9FBTCA-L3
BW9FBTGA-L3
BW9FBTHA-L3
BW9FBTJA-L3
BW9FWCA-15A
BW9FWGA-15A
BW9FWHA-15A
BW9FWHA-15A
BW9FWCA-20A
BW9FWGA-20A
BW9FWHA-20A
BW9FWHA-20A
BW9FWCA-30A
BW9FWGA-30A
BW9FWHA-30A
BW9FWHA-30A
MCCB
BW125JAGU*1
BW250EAGU
BW400EAGU
BW630RAGU
BW125RAGU
BW250JAGU
BW400SAGU
BW630HAGU
BW250RAGU
BW400RAGU
BW800RAGU
BW400HAGU
BW800HAGU
EW630RAGU
Main unit
Terminal
Applicable breakers
ELCB
Operating instructions
EW125JAGU
EW250JAGU
EW400SAGU
EW125RAGU
EW250RAGU
EW400RAGU
10,000
Ambient temperature
14 to 140F (- 10 to 40C)
Relative humidity
Protection
NEMA Type12
8,000
6,000
IP54 (IEC60529)
Conforming standards
Atmosphere
34
Drive section
MCCB/ELCB
2.559 (65)
Operation section
4.094 (104)
3.937 (100)
3.15 (80)
2.756 (70)
Terminal
cover
Mounting screw
M4 x 90
Handle
ON
1.063
(27)
Panel
2.244
(57)
1.772 (45)
1.142 (29)
Panel
ELCB
4.606 (117)
.2
2-0
0
2-
1.142 (29)
0.197dia
(M4 or 5)
0.512
(13)
Panel drilling
BW9F0GA
Drive section
di
R0
.25
6(
MCCB/ELCB
RESET
R6
.5)
Operation section
4.094 (104)
4.528 (115)
150
1.102(28)
or more
2.953
(75)
0.866
(22)
5.197 (132)
.5)
ia (
7d
1.083
(27.5)
.21
MCCB/
ELCB
76
7)
0.492
(12.5)
To operation section
1.181
(30)
OFF lock
Release screw
Cable
2.244 (57)
1.083 (27.5)
MCCB/ELCB
Release lever
4.685 (119)
Terminal
cover
2.362 (60)
5.197 (132)
3.543 (90)
5.866 (149)
Lock lever
Insulation
barrier
10.827 (275)
Max. 2.717
( 69)
*1
5.709 (145)
6.102 (155)
Concave for
ON lock*2
3.15 (80)
2.756 (70)
3.465
(88)
Mounting screw
M4 x 90
Handle
ON
1.063
(27)
Panel
2.244 (57)
1.772 (45)
1.142 (29)
Concave for
ON lock*2
Panel
4.606 (117)
150
10.827 (275)
OFF lock
Release screw
Cable
2.244 (57)
2-0
7)
2.953
(75)
Panel drilling
1.083 (27.5)
1.142 (29)
0.197 dia
(M4 or 5)
0.512
(13)
1.102 (28)
or more
R0
.25
4.685 (119)
.5
5
MCCB/
ELCB
di
RESET
1.083
(27.5)
ia (
7d
76
.
-0
.21
4.961 (126)
Release lever
0.492
(12.5)
To operation section
0.866
(22)
MCCB/ELCB
1.378
(35)
35
2.362
(60)
Terminal
cover
Lock lever
3.543
(90)
5.866 (149
Insulation
barrier
5.197 (132)
Max. 2.717
(69)
*1
5.709 (145)
6.496
(165)
MCCB/
ELCB
6(
R6
.5)
Drive section
Operation section
6.102(155)
Terminal
cover
7.48
(190)
3.15 (80)
4.252 (108)
Mounting screw
M6 x 110
10.827 (275)
Insulation
barrier
Handle
1.142 (29)
Concave for
ON lock*2
Panel
2.362 (60)
Release lever
6.732 (171)
To operation section
2.953 (75)
0.512
(13)
150
RESET
R0
1.083 (27.5)
1.142 (29)
.5)
ia (
1.083
(27.5)
7d
0.866
(22)
7)
0.492 (12.5)
2-
.21
7
.2
4.685 (119)
2-0
MCCB/
ELCB
OFF lock
Release screw
Cable
2.244 (57)
0.276 dia
(M6 or 7)
5.866 (149)
5.197 (132)
Lock lever
5.512 (140)
10.827 (275)
Max. 2.717
(69)
*1
1.732 (44)
1.063 (27)
Panel
2.244 (57)
1.772 (45)
MCCB/
ELCB
MCCB/ELCB
ON
5.709 (145)
MCCB/ELCB
.25
6(
R6
.5)
Panel drilling
BW9F0JA
Drive section
Operation section
6.102(155)
CL
MCCB/ELCB 9.055(230)
3.15 (80)
3.838(97.5)
Insulation
barrier
Handle
5.315(135)
Terminal
cover
ON
1.063 (27)
Panel
2.244 (57)
1.142 (29)
1.772 (45)
6.732(171)
1.083
(27.5)
2.953 (75)
0.866
(22)
1.142 (29)
.5
5
ia (
7d
CL
7)
0.492 (12.5)
0.
2-
.21
MCCB/
ELCB
6
27
0.512
(13)
Panel drilling
R0
4.685 (119)
2-0
MCCB/ELCB 0.276dia
CL
(M6 or 7)
OFF lock
Release screw
Cable
2.244 (57)
2.756(70)
5.197 (132)
Max. 2.717
(69)
8.268(210)
To operation section
1.083 (27.5)
Insulation
barrier
9.567(243)
2.362 (60)
Release lever
5.866 (149)
5.315(135)
Lock lever
150
*1
CL
5.709 (145)
Panel
MCCB/ELCB
10.827 (275)
10.827(275)
Concave for
ON lock*2
.25
6(
R6
.5)
RESET
36
E series Non-UL
Frame size
30AF
50AF
100AF
BW50RAGU-2P
EG32F / EG32A
(EW32AAG-2P)
EA33
BW50RAGU-3P
EW50RAGU-3P
2 poles
EA52A
BW50RAGU-2P
EG52F
(EW50AAG-2P)
EA52B
BW50RAGU-2P
EGa52A
(EW50AAG-2P)
EA53A
BW50RAGU-3P
EW50RAGU-3P
EA53B
BW50RAGU-3P
EG53B
EW50RAGU-3P
2 poles
EA62B
BW100EAGU-2P
3 poles
EA63B
BW100EAGU-3P
EW100EAGU-3P
2 poles
EA102A / EA102B
BW100EAGU-2P
EG102A / EG102B
EW100EAGU-2P
EA102H
BW125JAGU-2P
EA103F
BW100EAGU-3P
EW100EAGU-3P
EA103A / EA103B
BW100EAGU-3P
EG103AD / EG103BD
EW125JAGU-3P
EA103H / EA103K
BW125JAGU-3P
EG103K
EW100EAGU-3P
4 poles
EA104B
(BW125JAG-4P)
SGa104A(D)
(EW125JAG-4P)
2 poles
BW250EAGU-2P
EA202H
BW250JAGU-2P
BW250EAGU-3P
EGa203A(D)/EG203B(D)/EG203C(D) EW250JAGU-3P
EA203H
BW250JAGU-3P
BW400EAGU-2P
3 poles
BW400EAGU-3P
EGa403A(D)/EG403B(D)/EG403C(D) EW400SAGU-3P
600AF
3 poles
BW630RAGU-3P
EGa603A(D)/EG603B(D)/EG603C(D) EW630RAGU-3P
800AF
3 poles
BW800RAGU-3P
EGa803A(D)/EG803B(D)/EG803C(D) (EW800EAG-3P)
30AF
2 poles
EA32AC
BW50RAGU-2P
EG32AC
(EW32AAG-2P)
3 poles
EA33AC
BW50RAGU-3P
EG33AC / EG33C
EW50RAGU-3P
2 poles
EG52AC
(EW50AAG-2P)
3 poles
EG53AC / EG53C
EW50RAGU-3P
2 poles
EA62C
BW100EAGU-2P
3 poles
EA63C
BW100EAGU-3P
EG63C
EW100EAGU-3P
2 poles
EA102C
BW100EAGU-2P
EG102C
EW100EAGU-2P
3 poles
EA103BUL/EA103AC/EA103C
BW100EAGU-3P
EG103AC / EG103C
EW100EAGU-3P
EG103CD
EW125JAGU-3P
2 poles
EA102CUL
BW100EAGU-2P
EG102CUL
EW100EAGU-2P
3 poles
EA103CUL
BW100EAGU-3P
EG103CUL
EW100EAGU-3P
2 poles
SA32B
BW50RAGU-2P
3 poles
SA33B
BW50RAGU-3P
EW50RAGU-3P
2 poles
SA52B / SA52R
BW50RAGU-2P
SA52H
(BW50HAG-2P)
SA53B / SA53R
BW50RAGU-3P
EW50RAGU-3P
SA53H
(BW50HAG-3P)
4 poles
SA54B
(BW125JAG-4P)
2 poles
3 poles
BW100EAGU-2P
BW100EAGU-3P
EW100EAGU-3P
2 poles
SA102BA
BW125JAGU-2P
SA102RA
BW125RAGU-2P
SA102K
BW125JAGU-2P
SGa103A(D) / SG103B(D)
EW125JAGU-3P
SA103C
SG103C(D)
SG103H(D) / SG103R(D)
SA103RC
SG103RC(D)
SA103BN/SA103BAN/SA103CN -
SG103BA(D)
EW125JAGU-3P
SA103RN/SA103RAN/SA103RCN -
SG103RA(D)
EW125RAGU-3P
50AF
60AF
100AF
S series Non-UL
(Non-UL)
2 poles
400AF
UL489
Replacement - UL489
Models*1
EA32
3 poles
UL508
Discontinued
(Non-UL)
3 poles
3 poles
225AF
Replacement - UL489
Models
2 poles
3 poles
60AF
Discontinued
100AF
30AF
50AF
3 poles
60AF
100AF
3 poles
4 poles
225AF
2 poles
EW125RAGU-3P
SA103K
BW125JAGU-3P
SA104A
(BW125JAG-4P)
SA104H / SA104R
(BW125RAG-4P)
SGa104H(D)
(EW125RAG-4P)
SA202BA
BW250JAGU-2P
SA202RA
BW250RAGU-2P
SA202K
BW250EAGU-2P
37
H series Non-UL
Frame size
50AF
100AF
225AF
400AF
800AF
Replacement - UL489
Discontinued
Models
(Non-UL)
Models*1
Replacement - UL489
(Non-UL)
2 poles
H52BA / H52C
(BW50HAG-2P)
3 poles
H53BA / H53C
(BW50HAG-3P)
HG53B(D)
(EW50HAG-3P)
H53BAN / H53CN
H53CM
2 poles
H102BA / H102C
(BW125HAG-2P)
3 poles
H103BA / H103C
(BW125HAG-3P)
HG103B(D)
(EW125HAG-3P)
H103BAN / H103CN
HG103BN(D)
2 poles
H202BA / H202C
(BW250HAG-2P)
3 poles
H203BA / H203C
(BW250HAG-3P)
HG203B(D)
(EW250HAG-3P)
H203BAN / H203CN
(BX250HAE-3P)
HG203BN(D)
(EW250HAE-3P)
H402B / H402C
BW400HAGU-2P
H402BN / H402CN
(BW400HAA-2P)
H403B / H403C
BW400HAGU-3P
HG403B(D) / HG403C(D)
EW400HAGU-3P
H403BN/H403CN
(BW400HAA-3P)
HG403BN(D) / HG403CN(D)
H603B / H603C
BW630HAGU-3P
HG603B(D) / HG603C(D)
(EW630HAG-3P)
H603BN / H603CN
(BW630HAA-3P)
HG603BN(D) / HG603CN(D)
H803B / H803C
BW800HAGU-3P
HG803B(D)/ HG803C(D)
(EW800HAG-3P)
H803BN / H803CN
(BW800HAA-3P)
HG803BN(D) / HG803CN(D)
2 poles
3 poles
600AF
Discontinued
3 poles
3 poles
Replacement
Operating Handles
(V type)
Operating Handles
(N type)
BZ6V10D
BZ-V20B-3-Z
BZ-V30C / BZ-V30C-E
BZ-V40B-Z
BZ-V40C / BZ-V40C-E
BZ-V60B-Z
BZ-V70C-E
N-41A / N-120A
BZ-N20C
BZ6N10C
BZ6N10CP
BZ6V10D
BZ-N30C
BZ-N30C-*****
BZ-N40B
BZ-N40B-*****
BZ-N40C
BZ-N60B / BZ-N60C
BZ-N70C
Handle Lock Covers
BZ-L30C
BZ-L40C
Mechanical Interlock
BZ-M130C-2
BZ-S60B-225*
BZ-E30C-100*
: No replacement
38
S series
Non-UL
Frame size
225AF
3 poles
Discontinued
Replacement - UL489
Discontinued
Replacement - UL489
Models
(Non-UL)
Models*1
(Non-UL)
BW250JAGU-3P
4 poles
400AF
2 poles
3 poles
EW250JAGU-3P
SG203C(D)
SA203C
SA203H / SA203R / SA203RA
SGa203A(D) / SG203B(D)
BW250RAGU-3P
SG203H(D) / SG203R(D)
EW250RAGU-3P
SA203RC
SG203RC(D)
SG203BA(D)
EW250JAGU-3P
SG203RA(D)
EW250RAGU-3P
SA203K
BW250EAGU-3P
SGa204A(D)
(EW250JAG-4P)
SA204H / SA204R
(BW250RAG-4P)
SG204H(D)
(EW250RAG-4P)
BW400SAGU-2P
SGa403A(D) / SG403B(D)
EW400SAGU-3P
SA402BN / SA402CN
(BW400SAA-2P)
SA402RN / SA402RCN
(BW400RAA-2P)
BW400SAGU-3P
SG403C(D)
SA403H / SA403R / SA403RC
BW400RAGU-3P
SG403H(D) / SG403R(D)
EW400RAGU-3P
SG403RC(D)
600AF
SA403BN / SA403CN
(BW400SAA-3P)
SA403RN / SA403RCN
(BW400RAA-3P)
SA403L
BW400HAGU-3P
4 poles
SA404H / SA404HA
(BW400RAG-4P)
SGa404A(D)
(EW400RAG-4P)
3 poles
BW630RAGU-3P
SG603H(D) / SG603R(D)
EW630RAGU-3P
SG603RC(D)
SA603RC
800AF
SA603RN / SA603RCN
(BW630RAA-3P)
SA603L
BW630HAGU-3P
4 poles
SA604H
(BW630RAG-4P)
3 poles
SG803H(D) / SG803R(D)
(EW800RAG-3P)
SG803RC(D)
UL508
30AF
50AF
SA803RN
(BW800RAA-3P)
SA803L
BW800HAGU-3P
4 poles
SA804H
(BW800RAG-4P)
2 poles
SA32BUL / SA32C
BW50RAGU-2P
3 poles
SA33BUL / SA33C
BW50RAGU-3P
SG33C
EW50RAGU-3P
2 poles
SA52BUL / SA52RUL
BW50RAGU-2P
SG53C / SG53RC
EW50RAGU-3P
SG63C / SG63RC
EW100EAGU-3P
SA52C / SA52RC
3 poles
SA53BUL / SA53RUL
BW50RAGU-3P
SA53C / SA53RC
60AF
2 poles
SA62BUL / SA62RUL
BW100EAGU-2P
SA62C / SA62RC
3 poles
SA63BUL / SA63RUL
BW100EAGU-3P
SA63C / SA63RC
UL489
2 poles
SA52RCUL
BW50RAGU-2P
3 poles
SA53RCUL
BW50RAGU-3P
SG53RCUL
EW50RAGU-3P
2 poles
SA102BAUL / SA102CUL
BW125JAGU-2P
SA102RAUL / SA102RCUL
BW125RAGU-2P
SA103BAUL / SA103CUL
BW125JAGU-3P
SG103BAUL / SG103CUL
EW125JAGU-3P
SA103RAUL / SA103RCUL
BW125RAGU-3P
SA202BAUL / SA202CUL
BW250JAGU-2P
SA202RAUL / SA202RCUL
BW250RAGU-2P
SA203BAUL / SA203CUL
BW250JAGU-3P
SG203BAUL / SG203CUL
EW250JAGU-3P
SA203RAUL / SA203RCUL
BW250RAGU-3P
2 poles
SA402BUL / SA402CUL
BW400SAGU-2P
3 poles
SA403BUL / SA403CUL
BW400SAGU-3P
SG403CUL
EW400SAGU-3P
2 poles
SA402RUL / SA402RCUL
BW400RAGU-2P
3 poles
SA403RUL / SA403RCUL
BW400RAGU-3P
600AF
3 poles
SA603RUL / SA603RCUL
BW630RAGU-3P
800AF
3 poles
SA803RUL / SA803RCUL
BW800RAGU-3P
50AF
100AF
3 poles
225AF
2 poles
3 poles
400AF
39
BU series UL489
Frame size
100AF
2 poles
Discontinued
Replacement - UL489
Models
(Non-UL)
240VAC
3 poles
BU-ECA2
BU-ECA3 / BU3ECC (5-50A)
(60-100)
225AF
2 poles
BU-GCA2L
Reference
BW50RAGU-2P
BW100EAGU-2P
BW50RAGU-3P
BW100EAGU-3P
BW250EAGU-2PSB
BU-GDA2L
3 poles
BU-GCA3L
BW250EAGU-3PSB
BU-GDA3L
2 poles
BU-KDA2L
BW400EAGU-2PSB
3 poles
BU-KDA3L
BW400EAGU-3PSB
100AF
2 poles
BU-ESA2
BW125RAGU-2P
150AF
3 poles
2 poles
BU-ESA3
BU-FSA2
BW125JAGU-3P
BW125JAGU-2P
BU-FSA2150
BW250JAGU-2P150
BU-FHA2
BW125RAGU-2P
BU-FHA2150
BW250RAGU-2P150
BU-FSA3
BW125RAGU-3P
BU-FSA3150
BW250JAGU-3P150
BU-FHA3
BW125RAGU-3P
BU-FHA3150
BW250RAGU-3P150
2 poles
BU-JSA2 / BU-JHA2
3 poles
BU-JSA3 / BU-JHA3
2 poles
BU-KSA2 / BU-KHA2
3 poles
BU-KSA3 / BU-KHA3
2 poles
3 poles
2 poles
3 poles
2 poles
3 poles
400AF
UL489
480VAC
3 poles
250AF
400AF
600AF
800AF
1200AF
UL489
600VAC
100AF
150AF
BU-FHB2 / BU2FHC
BU-FHB2150
BU-FHB3 / BU3FHC
BU-FHB3150
2 poles BU-FSB2
BU-FSB2150
3 poles BU-FSB3
BU-FSB3150
250AF
400AF
600AF
800AF
1200AF
Discontinued Models
Replacement
40
MEMO:
41
Quotations
Written quotations are valid for 30 days from its date
unless otherwise stated in the quotation. Verbal
quotations expire the same day they are made.
Taxes
The price does not include any taxes. Buyer shall be
responsible for the payment of all applicable taxes.
Terms of payment
Terms of payment will be listed on the quotations.
Minimum orders
Terms of minimum order will be shown on quotations,
or if orders amounting to less than the latest minimum
order amount, a handling fee will be applied.
Delivery
Delivery of products shall be FOB point of origin in the
U.S. Seller shall determine the point of origin of
shipment. All shipping and other charges shall be paid
by Buyer.
Packing
Prices include standard domestic packing. Additional
special packing costs required for export or by Buyer's
request will be charged to Buyer.
Return / Cancellation
No product shall be returned or canceled unless
return/order cancel authorization has been secured
from Seller. All returns/cancellations must comply with
Seller's then current Return / Cancellation policy.
Risk of Loss
Risk of loss or damage to the product shall pass to
Buyer at the FOB point.
Catalog Disclaimer
The information contained in this catalog does not
constitute an express or implied warranty of quality,
any warranty of merchantability or fitness for a
particular purpose is hereby disclaimed.
Since the Buyer's product information, specific use
application, and conditions of use are all outside of
Seller's control, it shall be the responsibility of the
Buyer to determine the suitability of any of the
products mentioned for the Buyer's application.
42