You are on page 1of 3

Data Collection Form HUDCO Green Initiatives

Basic Information
Project name

TERI University Hostel Block

Year of construction

2007-08

Location & Address

TERI University, New Delhi

Climate (as per


NBC)
Site area

Composite
Name

Contact Information

Architect

Sanjay Mohe

080-23515501/02

Contractor

Confoss Constructions

09310270358

Developer

Confoss

MEP

Confoss

Energy consultant

Airtron Consultants

Total Cost of
Construction
Total Built up Area
(Sq. mts)
Total site area (sq.
mts.)
Green
technologies/featur
es incorporated

09845452426

8143.47 Sqm
8152.60 Sqm
Orientation, Reflective finish roof, STP, RWH, Material
reuse from site, local materials, Passive design features,
Earth Air Tunnel

Materials
Glass
Glazing U-Factor (W/m2-C) See detail at the end
Visible light transmittance (VLT)

See dtl at the end

Roof
Roof U-Factor (W/m2-C) OR,
External Roof Construction
Material Description

Thickness (mm)

Layer 1 (Outside
layer) 2
Layer

Brick Bat Coba Waterproofing


Insulation of vermiculate/PUF

125mm

Layer 3

Screed protection with reflective


tile

Layer 4

175/50 mm
50mm

Layer 5
Layer 6
Roof Insulation details (Type, thickness,
R- value)

175mm Vermiculate/50mmPUF board


Insulation, R-15

Reflectivity of finishing (indoor/outdoor)

Broken china Mozaic/Pebble

Wall
Wall U-Factor (W/m2-C) OR,
External Wall Construction
Material Description

Thickness (mm)

Layer 1 (Outside
layer)
Layer 2

Brickwork

230mm

PUF board

50mm

Layer 3

Brickwork

115mm

Layer 4
Layer 5

Layer 6
Wall insulation details (Type, thickness,
R-value)

PUF insulation R-15

Reflectivity of finishing (indoor/outdoor)

Plastered inside with white emulsionpaint.


Outside Sandstone Cry cladding

HVAC
Is the building naturally ventilated

Yes

Any ACs provided

No direct AC

Any passive and active technologies


incorporated to reduce the AC energy
load

Earth Air Tunnel. (Please specify total cost


involved if available) 107 Lakhs

Lighting
Lighting System (Please specify the type of different kind of fixtures and their
respective
wattages installed)
Internal Lighting
Total Lighting load (kW)
Type and wattage of lamps predominantly used
(LED/FTL/CFL/MH)
Type 1

Fixture Type/System
Wattage

Type 2
Type 3
Type 4
Type 5
Type 6

External Lighting
Type, Number of Lighting fixtures

Type/Nos./

Type 1
Type 2
Type 3
Type 4
Exterior lighting controls (Photo sensor/Astronomical time
switch/Any other)

1. Double-glazed units for south faade with following configuration and properties:
6mm Solar Low e Clear #2 toughened with 12 mm Gap with Argon and 6 mm clear float annealed glass with light
transmission 55%, U value 0.32 BTU/sq.ft F and solar efficient of 0.44.
2. Double-glazed units for north faade with following configuration and properties:
6mm energy advantage low e clear #2 toughened with 12 mm Gap with Argon and 6 mm clear float annealed glass
with light transmission 73%, U value 0.30 BTU/ft2 F and solar efficient of 0.61.