You are on page 1of 2

RHEOCEM 650

Fast setting microfine Portland cement for injection into rock and soil

DESCRIPTION PROPERTIES
Rheocem 650 is a microfine Portland cement for rock Fineness (Blaine) >625m /kg
2

and soil injection. Because of Rheocem 650’s small Particle size distribution:
particle size and a specially adapted admixture system, it <40 microns 100%
penetrates very well into tight joints, fissures and pore <30 microns 98%
spaces to provide a water-tight grouted rock or soil mass. <20 microns 97%
Rheocem 650 is a well-graded cement milled from pure <15 microns 94%
Portland cement clinker with a Blaine value of 650 m2/kg. <10 microns 77%
Rheocem 650 achieves initial and final setting faster than <5 microns 44%
normal and microfine cements. This increases productivity <2 microns 16%
in a tunnel grouting operation. The short open time of 1 to APPLICATION
1½ hours and a very short setting time of 2½ hours
reduce the waiting time for the next activity to start to a Rheocem 650 shall always be used with Rheobuild 1000
minimum (at about 20 °C) water reducing admixture (1.0 - 3.0 % of cement weight.)
Water/cement ratio (by weight) shall normally be between
RECOMMENDED FOR 0.5 -1.0.
• Rock injection: Tunnels, caverns, mines, etc., used for
pre- and post excavation injection. Ground water Mixing
sealing and ground stabilisation. • Fill the mixer with water
• Soil injection: Ground stabilisation, ground water • Add cement. Mix for 2 minutes.
sealing. • Add Rheobuild 1000 and mix for another minute
• Prepacked injection • Transfer to agitator
• Contact injection
FEATURES AND BENEFITS It is very important to use an efficient mixer. Colloidal
mixers are the best, but high-speed paddle mixers are
• Standard cement injection equipment can be used acceptable.
• Better penetration in tight joints, fissures and pore Minimum rpm. for colloidal mixers - 1500 rpm.
spaces Minimum rpm for paddle mixers - 400 rpm.
• Greater penetration imparts greater water
tightness NB: Do not over mix. Mixing longer than recommended
• Fast setting may cause the grout temperature to increase and set in
• Better working environment and no haza hazardous
rdous the pump and hoses.
components
• Durable POT LIFE
• Economical solution The mix shall be kept under constant agitation prior to
SETTING TIMES injection. Do not keep grout in agitator longer than 30 – 40
minutes stored in original closed bags in ventilated dry
The setting times, at a 1:1 water/cement ratio (by weight) areas.
and at 20° C are as follows:
INJECTION
Initial set:60-120 min
(Measured by Vicat needle) High-pressure piston pumps are normally used to pump
Final set: 120-150 min the suspension into the rock. The grout should be
(1 mm penetration by Vicat needle) injected within 30 –40 minutes after mixing to ensure that
it keeps penetrating into the fissures. Longer open times
Injection grout properties indicated below, relates to a mix can be achieved by Delvocrete Stabiliser hydration
containing 1.5% Rheobuild 1000:000 control admixture. For much longer open times, an
alternative is to use Rheocem 650SR,
650SR which gives longer
Mud balance 1.48-1.50 kg/l open time.
Water/cement ratio 1.0
HARDENING
Flow cone 32-34 seconds
Bleeding maximum 1% Rheocem 650 will have set sufficiently after 2 - 2½ hours
to allow drilling to commence for control or blast holes.
PACKAGING
Rheocem
Rheocem 650 is supplied in 20 kg and 1000kg bags.
RHEOCEM 650
SHELF LIFE
Rheocem 650 has a shelf life of 6 months when stored in
original closed bags in ventilated dry areas.
PRECAUTIONS
Any physical contact (e.g. skin or eyes) made with
Rheocem 650 should be avoided, as it may cause
irritation or burns.
If such contact occurs, the affected area should be
washed with plenty of clean water. In case of eye contact,
seek immediate medical advice.
For further information please refer to the Material Safety
Data Sheet

The technical information and application advice given in this publication are based on
the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is
responsible for checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by either orally or
in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
, are responsible for carrying out procedures appropriate to a specific application.

Incorporated in NSW A.B.N. 46 000 450 288


11 Stanton Road Seven Hills, NSW 2147 Australia Ph. (02) 8811 4200
(02) 4961 3819 (07) 3633 9900 (07) 4774 7344 (03) 9549 0300
(08) 8139 7500 (08) 9366 2600 0417 772 355
45 William Pickering Drive, Albany, Auckland Ph: (09) 414 7233