Small parts,

big impact.
Insulated and non-insulated
cableconnections.
To guarantee ultimate safety at all times, specic quality and
installation requirements exist for insulated and non-insulated
connections. We often hear about technical failures being
caused by faulty connections. Thats why quality is so important.
Because when it comes to electrical connections, minor causes
can have major, expensive consequences.
For optimum processing of Klauke connecting materials, we
therefore recommend the use of Klauke tools. A harmonised
system for professional users in trade and industry.

Insulated and non-insulated cable


connections for professional users.
Halogen-free insulation.
Insulated connectors, heat resistant to
105C.
Hard-soldered in the crimping area.

172

The Klauke range carries various


designs of both insulated and noninsulated cable connections for diverse
applications.

Heat resistant insulation to 105 C.


Cable connections with nominal cross-sections from
0.1 mm2 to 6 mm2.
Halogen-free and heat resistant to 105 C.
Simple processing thanks to easy-entry insulation.
Hard-soldered in the crimping area.
Grooved prole on the inside.
Benets:
The use of these optimised quality materials guarantees reliable
electrical connections.
Electrical conductivity is maintained, even at higher temperatures.
Halogen-free, ame-retardant polyamide insulation releases no toxic vapours in case of re.
Easy-entry polyamide insulation for simple conductor insertion.
High-tensile strength thanks to grooved prole in the crimping area permits higher mechanical continuous stress.

Receptacles with strain relief.


Standardised connectors with 2.8; 4.8; 6.3 and 9.5 mm tab width.
With grooved prole and additional copper ring in the insulation
area.
Receptacles, multiple type.
Fully-insulated receptacles.
Benets:
Standardised tabs enable use for a broad range of applications,
including control installations and machine wiring.
The grooved prole increases the hold in the crimping area.
The connections relieved by copper rings in the crimping area
better withstand stresses and vibrations.
More from Page 179.

With indent point for dened pulling forces.


Receptacle with indent point.
For harmonised, exible cables.
Receptacles also available in bronze.
Benets:
The additional indent point increases the mechanical rating and
guarantees that the connections will withstand the dened
pulling forces even after repeated pulling actions.

More from Page 179.

Thanks to the materials improved spring characteristics, connectors with


bronze receptacles have a higher contact strength and are able to better
withstand mechanical stresses, especially at high temperatures.

173