DMPR
Electronic protection type up to 60A
with Micro controller unit & Digital display part
General digital type motor protection relays using MCU(Micro Controller Unit)
- Real time processing and high precision
-S & DMP
-Sa
DMP
-T & DMP
-Ta
DMP
Both screw type and tunnel type wrings are available in a DMP-E Type D-EMPR
- Simply detach the screw terminal, you can use it by the tunnel type relay
General digital type motor protection relays using MCU(Micro Controller Unit)
- Real time processing and high precision
Multiple protection
-S/Sa
DMP
Protection
-SZ/SZa
DMP
Wiring
-SI
DMP
-T/Ta
DMP
Screw type
-TZ/TZa
DMP
Over current
Under current
Stall
Lock
Phase failure
Revers phase
Asymmetry
Ground fault
Short circuit
IEC 60947
Standard:
IEC60947-1, IEC60947-4-1, IEC60947-5-1, UL508, KSC4504
12
-TI
DMP
Tunnel type
Elegant design
High class product image by the elegant design
13
-S & DMP
-Sa
DMP
Model No.
-T & DMP
-Ta
DMP
DMP06-S/Sa
Wiring
Panel mount
Over current
Phase failure
3 sec.
Reverse phase
Asymmetry
5 sec.
Stall
5 sec.
Lock
Under current
3 sec.
Ground fault
Within 50ms
Alarm
220~240V
(kW)
380~440V
0.5~6
5~60
0.5~6
5~60
0.09~0.75
1.1~11
0.09~0.75
1.1~11
0.12~1.5
2.2~22
0.09~1.5
2.2~22
Time setting
Definite
Delay in starting
0~60sec
range (sec)
time
Delay in operating
0~30sec
Inverse time
0~60sec
Reset
Tolerance
Manual reset
Current
5%
Time
5% (or0.5sec)
Operating power
Voltage
AC 190~250V
Note3)
Frequency
60Hz (50Hz)
OL
2-SPST
AL
SPST
Insulation resistance
2.5kV/5min
Environment
-25~70
Temperature
Operation
Storage
Humidity
Mounting type
-30~80
30~90% RH (No freezing)
7-Segment
Bar-Graph
Note1) In extension type, the digital EMPR is calibrated with combining the display past and main body so,
please cautious not to combine the display part and main body with different part No.
Note2) Instantaneous short circuit protection is optional
Note3) Operational voltage of AC 110V and 50Hz is optional
84
DMP60-T/Ta
Tunnel type
Protection
Display
DMP06-T/Ta
Operation time
Aux. contact
DMP60-S/Sa
Screw type
Protect function
Over current
Phase loss
Phase unbalance
Phase reverse
Stall
Lock
Under current
Note) Lock protection is operated after setting D-time in case of definite time type
Function selection
FUNC
1. CHA
2. dEF
3. r.P
4. Und
5. Alt
6. Stl
7. Loc
8. Ct
9. P.F
b. StA
c. StH
d. tAH
E. rAH
Sto
Sel
Inv/dEF
0~30(S)
oFF/on
oFF/30~70(%)
oFF/60~110(%)
oFF/on
oFF/200~900(%)
1~120
on/oFF
0~120
10~730
A000,000.0
A000,000.0
Sto
Description
Operating characteristics setting(Inverse/definite time type)
Setting the operating time(In definite type)
Phase reverse enable
Under current enable and setting
Alerting enable and setting
Stall enable
Lock enable and setting
CT ratio setting
Phase fault enable
Operating time setting by month
Operating time setting by hour
Displaying total operating time (month, hour)
Displaying operating time (month, hour)
Store
Ratings
Model
Type
Wiring method
Panel mount
Operating characteristics
Alerting function
Current
DMP06-
range(A)
DMP60-
Setting time
Definite Delay(D-T)
Operating(O-T)
Inverse
Reset type
Operating
Voltage
voltage
Frequency
Aux. contacts OL
2-SPST(95~98)
AL
SPST(07-08)
Indicate
7-segment
Bar-LED arrays
Mounting
-S/Sa
DMP
Screw
-T/Ta
DMP
Tunnel
Unit or Extension
Inverse/definite type
Variable between 60 and 110%
0.5~6
5~60
0~60seconds
0~30seconds
0~60seconds
Manual reset
AC 190~250V
60Hz (50Hz)
3A/250Vac resistive load
3A/250Vac resistive load
3-phase current value, fault cause
Load ratio (60~110%)
35mm Din-rail/Panel
105
Note) Lock protection is operated after setting D-time in case of definite time type
Function selection
FUNC
1. CHA
2. dEF
3. r.P
4. Und
5. g-F
6. Stl
7. Loc
8. Ct
9. P.F
A. gFd
b. StA
c. StH
d. tAH
E. rAH
Sto
Sel
Inv/dEF
0~30(S)
oFF/on
oFF/30~70(%)
oFF/0.05~1.0(S)
oFF/on
oFF/200~900(%)
1~120
on/oFF
oFF/on
0~120
10~730
A000,000.0
A000,000.0
Sto
Description
Operating characteristics setting(Inverse/definite time type)
Setting the operating time(In definite type)
Phase reverse enable
Under current enable and setting
Ground fault enable and setting
Stall enable
Lock enable and setting
CT ratio setting
Phase fault enable
Setting delay of ground fault
Operating time setting by month
Operating time setting by hour
Displaying total operating time (month, hour)
Displaying operating time (month, hour)
Store
Ratings
Model
Type
Wiring method
Panel mount
Operating characteristics
Alerting function
Current
DMP06-
range(A)
DMP60-
Setting time
Definite
Delay(D-T)
Operating(O-T)
Inverse
Reset type
Operating
voltage
voltage
Frequency
ZCT input (07-08)
Aux. contacts(2a, 2b, 1a1b) OL, GR 2-SPST(95~98)
Indicate
7-segment
Bar-LED arrays
Mounting
106
-SZ/SZa
-TZ/TZa
DMP
DMP
Screw
Tunnel
Unit or Extension
Inverse/definite type
Variable between 60 and 110%
0.5~6
5~60
0~60seconds
0~30seconds
0~60seconds
Manual reset
AC 190~250V
60Hz (50Hz)
200mA/110mV(ZCT)30, 50, 65, 80
3A/250Vac resistive load
3-phase current value, fault cause
Load ratio (60~110%)
35mm Din-rail/Panel
Setting method
DMPR
Digital display
R phase
S phase
Bar graph
Display button
T phase
Test/Reset button
Sel button
FUNC button
Current knob
Time knob
2. Shift the mode by pressing the FUNC key and then select the values by press the Sel key
You can finish the setting by pressing the Sel key in the Sto mode
To protect the operation under the motor rotating, setting is allowed only in the test mode
FUNC
Sel
Functions
Note
characteristics
characteristics
Default isOff
Default isOffNote1)
Alarm function
(With pre-alarm function)
Default isOff
Default is Off
(Z type)
Stall function
Default isOff
Lock function
Default isOff
CT ratio
Phase failure
Default isOn
to store
Available for
Sa/Ta/SZa/TZa
(Month, Hour)
Displaying operating time
(Month, Hour)
Store
143
Technical information
Setting method
1) First shift to the test mode by press the
Test/Resetbutton and then set the functions by press the
FUNCbutton
2) Each time you press the
FUNCbutton, the function mode switches from 1.CHA mode to Sto mode.
When the mode that you want to change is displayed, push the
Selbutton to select the value you want.
After you select the value, press the
FUNCbutton to finish the settings and it displays the next mode
3) If no button is pressed in the selection mode, it remains in that mode
5.ALt
On
1
0
Off
Normal
Alarm
Alert setting
value
Trip
Trip setting
value
144
DMPR
5. Check the setting state by the display key
R
S
R phase current
S phase current
R
S
T
Normal condition
R
T phase current
R
S
T
5A setting
6. Check the causes of the fault by look at the display unit (7-segment)
The causes of the fault is switched on and off for 0.5sec interval. If you press theDisplaybutton at this time, display you can
see the values and the causes of the fault
Turn on
ex)
R
S
Overload
Under current
Reverse phase
Turn
on & off
R
R
S
Phase fail
Ground fault
Stall
Short circuit
R
S
T
S
T
Lock
145
Technical information
Setting method
7. How to check operating time for Sa/Ta/SZa/STa
R
S
T
10 min
1 hour
20 min
50 min
30 min
R
S
T
40 min
146
Wiring method
DMPR
Wiring method
Operational
power
DMP-S/Sa
DMP-T/Ta
External CT combination
DMP-S/Sa
DMP-T/Ta
Note1) Please turn off the reverse phase function when it is used for 1 phase motor
147
Technical information
Wiring method
Wiring method
DMP-SZ/SZa
DMP-TZ/TZa
External CT combination
DMP-SZ/SZa
DMP-TZ/TZa
Note1)
Note1) Please turn off to page for zero-phase sequence current transformer.
148
Dimensions
Digital motor protection relay
DMP-S
Mounting
DMP-SZ
dimensions
DMP-Sa
DMP-SZa
0.7kg
DMP-S
Mounting
DMP-SZ
dimensions
DMP-Sa
DMP-SZa
0.64kg
Panel mounting
210
DMP-T
Mounting
DMP-TZ
dimensions
DMP-Ta
DMP-TZa
0.56kg
DMP-T
Mounting
DMP-TZ
dimensions
DMP-Ta
DMP-TZa
0.5kg
Panel mounting
211