Professional Documents
Culture Documents
LINE PRODUCTS
CELLFLEX Cable
SCF14-50 Series
1/4 Superflexible Foam Coax
APPLICATIONS
OEM jumpers, BTS inter-cabinet connections, GPS lines, Riserrated In-Building (JFN types, only), Microwave IF cabling
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Superflexible
Size
1/4
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
1.9 (0.075)
(in)
Diameter Dielectric, mm (in)
4.3 (0.170)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
6.5 (0.26)
Conductor, mm (in)
Diameter over Jacket Nominal,
7.8 (0.31)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.07 (0.05)
Minimum Bending Radius,
25 (1.0)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
0.7 (0.5)
Flat Plate Crush Strength, N/mm
18.4 (100)
(lb/in)
Tensile Strength, N (lb)
600 (135)
Recommended / Maximum Clamp
0.20 / 0.20 (0.67 / 0.67)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
82
Capacitance, pF/m (pF/ft)
82.0 (25.0)
Inductance, H/m (H/ft)
0.207 (0.063)
Maximum Frequency, GHz
20.4
Peak Power Rating, kW
5.5
RF Peak Voltage, Volts
740
Jacket Spark, Volt RMS
5000
Inner Conductor dc Resistance,
10.40 (3.17)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
6.60 (2.01)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
SCF14-50J
SCF14-50JFN
30
www.rfsworld.com
Jacket
Standard
Flame Retardant
CELLFLEX Cable
APPLICATIONS
OEM jumpers, BTS inter-cabinet connections, GPS lines, Riserrated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Superflexible
Size
3/8
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
2.6 (0.1)
(in)
Diameter Dielectric, mm (in)
6.3 (0.25)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
9.1 (0.36)
Conductor, mm (in)
Diameter over Jacket Nominal,
10.2 (0.4)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.12 (0.08)
Minimum Bending Radius,
25 (1.0)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
1.4 (1.0)
Flat Plate Crush Strength, N/mm
18.4 (100)
(lb/in)
Tensile Strength, N (lb)
600 (135)
Recommended / Maximum Clamp
0.25 / 0.25 (0.80 / 0.80)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
82
Capacitance, pF/m (pF/ft)
82.0 (25.0)
Inductance, H/m (H/ft)
0.207 (0.063)
Maximum Frequency, GHz
13.4
Peak Power Rating, kW
11.9
RF Peak Voltage, Volts
1090
Jacket Spark, Volt RMS
5000
Inner Conductor dc Resistance,
5.3 (1.62)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
5.6 (1.71)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
Attenuation
Attenuation
Average
dB/100 m
0.291
0.412
0.505
0.584
1.31
1.86
2.28
2.96
3.95
4.22
4.39
5.20
5.61
6.03
7.45
8.66
9.22
9.74
9.87
10.7
11.7
12.5
12.7
13.3
13.3
13.5
13.8
14.1
15.9
17.6
18.8
19.4
20.6
21.1
21.7
22.8
25.8
28.2
30.4
34.6
38.4
42.1
45.6
48.9
52.1
58.2
62.3
dB/100 ft
0.0888
0.126
0.154
0.178
0.400
0.567
0.696
0.903
1.21
1.29
1.34
1.59
1.71
1.84
2.27
2.64
2.81
2.97
3.01
3.27
3.55
3.81
3.87
4.05
4.06
4.12
4.20
4.30
4.85
5.36
5.74
5.92
6.27
6.45
6.61
6.94
7.87
8.59
9.27
10.5
11.7
12.8
13.9
14.9
15.9
17.7
19.0
Power kW
11.9
11.9
11.9
11.9
6.02
4.24
3.46
2.67
2.00
1.87
1.80
1.52
1.41
1.31
1.06
0.912
0.857
0.810
0.800
0.736
0.678
0.631
0.621
0.595
0.593
0.584
0.572
0.560
0.496
0.449
0.420
0.407
0.384
0.373
0.364
0.347
0.306
0.280
0.260
0.228
0.205
0.188
0.173
0.161
0.152
0.136
0.127
TRANSMISSION
LINE PRODUCTS
SCF38-50 Series
3/8 Superflexible Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
SCF38-50J
SCF38-50JFN
SCF38-50JGR
Jacket
Standard
Flame Retardant
Standard, Gray
31
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
SCF12-50 Series
1/2 Superflexible Foam Coax
APPLICATIONS
OEM jumpers, Main feed transitions to equipment, GPS lines,
Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Superflexible
Size
1/2
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
3.6 (0.14)
(in)
Diameter Dielectric, mm (in)
8.3 (0.33)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
12.3 (0.48)
Conductor, mm (in)
Diameter over Jacket Nominal,
13.7 (0.54)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.21 (0.14)
Minimum Bending Radius,
32 (1.25)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
1.8 (1.3)
Flat Plate Crush Strength, N/mm
20.4 (110)
(lb/in)
Tensile Strength, N (lb)
650 (146)
Recommended / Maximum Clamp
0.30 / 0.30 (1.00 / 1.00)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
82
Capacitance, pF/m (pF/ft)
82.0 (25.0)
Inductance, H/m (H/ft)
0.207 (0.063)
Maximum Frequency, GHz
11.7
Peak Power Rating, kW
20.5
RF Peak Voltage, Volts
1430
Jacket Spark, Volt RMS
5000
Inner Conductor dc Resistance,
2.9 (0.88)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
3.4 (1.04)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
SCF12-50J
SCF12-50JFN
SCF12-50JGR
32
www.rfsworld.com
Jacket
Standard
Flame Retardant
Standard, Gray
CELLFLEX Cable
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only), Jumper
for attenuation sensitive application
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Ultraflexible
Size
7/8
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
9.42 (0.371)
(in)
Diameter Dielectric, mm (in)
21.1 (0.83)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
24.89 (0.980)
Conductor, mm (in)
Diameter over Jacket Nominal,
27.48 (1.082)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.432 (0.290)
Minimum Bending Radius, Single
90 (3.5)
Bend, mm (in)
Minimum Bending Radius,
125 (5)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
13.0 (9.6)
Flat Plate Crush Strength, N/mm
14.3 (80)
(lb/in)
Recommended / Maximum Clamp
0.8 / 1.0 (2.75 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
88
Capacitance, pF/m (pF/ft)
76 (23.2)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
4.9
Peak Power Rating, kW
83
RF Peak Voltage, Volts
2850
Jacket Spark, Volt RMS
8000
Inner Conductor dc Resistance,
2.82 (0.86)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
1.04 (0.32)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
TRANSMISSION
LINE PRODUCTS
UCF78-50A Series
7/8 Ultraflexible Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
UCF78-50JA-P*
UCF78-50JFNA-P*
Jacket
Standard
Flame Retardant
33
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
UCF114-50A Series
1-1/4 Ultraflexible Foam Coax
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Ultraflexible
Size
1-1/4
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
13.6 (0.54)
(in)
Diameter Dielectric, mm (in)
31.2 (1.23)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
36.0 (1.42)
Conductor, mm (in)
Diameter over Jacket Nominal,
39.0 (1.54)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.81 (0.55)
Minimum Bending Radius, Single
150 (6.0)
Bend, mm (in)
Minimum Bending Radius,
250 (10)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
36.0 (25.6)
Flat Plate Crush Strength, N/mm
25.5 (140)
(lb/in)
Tensile Strength, N (lb)
2900 (650)
Recommended / Maximum Clamp
1.0 / 1.2 (3.25 / 4.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
89
Capacitance, pF/m (pF/ft)
75 (22.9)
Inductance, H/m (H/ft)
0.184 (0.056)
Maximum Frequency, GHz
3.6
Peak Power Rating, kW
178
RF Peak Voltage, Volts
4200
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
2.20 (0.67)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.62 (0.19)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
UCF114-50JA-P*
UCF114-50JFNA-P*
34
www.rfsworld.com
Jacket
Standard
Flame Retardant
CELLFLEX Cable
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1-1/4
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
13.8 (0.55)
(in)
Diameter Dielectric, mm (in)
31.0 (1.22)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
36.0 (1.42)
Conductor, mm (in)
Diameter over Jacket Nominal,
39.0 (1.54)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.79 (0.53)
Minimum Bending Radius, Single
150 (6.0)
Bend, mm (in)
Minimum Bending Radius,
250 (10)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
36.0 (25.6)
Flat Plate Crush Strength, N/mm
25.5 (140)
(lb/in)
Tensile Strength, N (lb)
2900 (650)
Recommended / Maximum Clamp
1.0 / 1.2 (3.25 / 4.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
89
Capacitance, pF/m (pF/ft)
75 (22.9)
Inductance, H/m (H/ft)
0.184 (0.056)
Maximum Frequency, GHz
3.3
Peak Power Rating, kW
178
RF Peak Voltage, Volts
4200
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
1.94 (0.59)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.55 (0.17)
ohm/1000 m (Ohm/1000 ft)
UCF114-50JA/JFNA PREMIUM
ATTENUATION AND AVERAGE POWER
Frequency Attenuation Attenuation
MHz
dB/100 m
dB/100 ft
0.5
0.059
0.018
1.0
0.084
0.026
1.5
0.103
0.032
2.0
0.119
0.036
10
0.269
0.082
20
0.382
0.120
30
0.470
0.143
50
0.611
0.186
88
0.819
0.250
100
0.875
0.267
108
0.911
0.278
150
1.08
0.330
174
1.17
0.357
200
1.26
0.384
300
1.56
0.476
400
1.82
0.556
450
1.95
0.593
500
2.06
0.628
512
2.09
0.636
600
2.28
0.694
700
2.48
0.755
800
2.67
0.813
824
2.71
0.827
894
2.84
0.865
900
2.85
0.868
925
2.89
0.882
960
2.95
0.900
1000
3.02
0.921
1250
3.43
1.05
1500
3.80
1.16
1800
4.22
1.29
2000
4.49
1.37
2200
4.75
1.45
2300
4.87
1.49
3000
5.71
1.74
3300
6.04
1.84
Average
Power kW
178
128
104
90.1
40.0
28.1
22.9
17.6
13.1
12.3
11.8
9.93
9.19
8.54
6.88
5.89
5.53
5.22
5.15
4.72
4.34
4.03
3.96
3.79
3.77
3.72
3.64
3.56
3.14
2.83
2.54
3.39
2.26
2.21
1.88
1.78
TRANSMISSION
LINE PRODUCTS
UCF114-50A Series
1-1/4 Premium Attenuation
Ultraflexible Low-Loss Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
UCF114-50JA-A*
UCF114-50JFNA-A*
Jacket
Standard
Flame Retardant
35
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCF14-50 Series
1/4 Low-Loss Foam Coax
APPLICATIONS
OEM jumpers, BTS inter-cabinet connections, GPS lines, Riserrated In-Building (JFN types, only), Microwave IF cabling
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1/4
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
2.4 (0.09)
(in)
Diameter Dielectric, mm (in)
6.0 (0.24)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
7.5 (0.3)
Conductor, mm (in)
Diameter over Jacket Nominal,
10 (0.39)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.11 (0.074)
Minimum Bending Radius, Single
40 (1.6)
Bend, mm (in)
Minimum Bending Radius,
120 (5)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
1.9 (1.4)
Flat Plate Crush Strength, N/mm
14 (80)
(lb/in)
Tensile Strength, N (lb)
890 (200)
Recommended / Maximum Clamp
0.5 / 1.0 (1.75 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1.5
Velocity, percent
83
Capacitance, pF/m (pF/ft)
80 (24)
Inductance, H/m (H/ft)
0.205 (0.063)
Maximum Frequency, GHz
15.8
Peak Power Rating, kW
10.9
RF Peak Voltage, Volts
1050
Jacket Spark, Volt RMS
5000
Inner Conductor dc Resistance,
6.1 (1.86)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
3.5 (1.25)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
LCF14-50J
LCF14-50JFN
36
www.rfsworld.com
Jacket
Standard
Flame Retardant
CELLFLEX Cable
APPLICATIONS
OEM jumpers, BTS inter-cabinet connections, GPS lines, Riserrated In-Building (JFN types, only), Microwave IF cabling
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
3/8
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
3.1 (0.12)
(in)
Diameter Dielectric, mm (in)
7.2 (0.28)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
9.5 (0.37)
Conductor, mm (in)
Diameter over Jacket Nominal,
11.2 (0.44)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.12 (0.08)
Minimum Bending Radius, Single
50 (2)
Bend, mm (in)
Minimum Bending Radius,
95 (4)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
1.9 (1.4)
Flat Plate Crush Strength, N/mm
20.4 (110)
(lb/in)
Tensile Strength, N (lb)
530 (119)
Recommended / Maximum Clamp
0.5 / 1.0 (1.75 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1.5
Velocity, percent
88
Capacitance, pF/m (pF/ft)
76.0 (23.2)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
13.5
Peak Power Rating, kW
15.4
RF Peak Voltage, Volts
1240
Jacket Spark, Volt RMS
5000
Inner Conductor dc Resistance,
3.8 (1.16)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
2.9 (0.88)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
TRANSMISSION
LINE PRODUCTS
LCF38-50 Series
3/8 Low-Loss Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
LCF38-50J
LCF38-50JFN
Jacket
Standard
Flame Retardant
37
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCF12-50 Series
1/2 Low-Loss Foam Coax
APPLICATIONS
OEM jumpers, Main feed transitions to equipment, GPS lines,
Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1/2
STRUCTURE
Inner Conductor Material
Copper-Clad Aluminum Wire
Diameter Inner Conductor, mm
4.8 (0.190)
(in)
Diameter Dielectric, mm (in)
11.3 (0.44)
Outer Conductor Material
Annularly Corrugated Copper
Diameter Copper Outer
13.8 (0.54)
Conductor, mm (in)
Diameter over Jacket Nominal,
16.2 (0.64)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.22 (0.15)
Minimum Bending Radius, Single
70 (3)
Bend, mm (in)
Minimum Bending Radius,
125 (5)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
5.0 (3.7)
Flat Plate Crush Strength, N/mm
20.4 (110)
(lb/in)
Tensile Strength, N (lb)
1100 (247)
Recommended / Maximum Clamp
0.6 / 1.0 (2.0 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
88
Capacitance, pF/m (pF/ft)
76.0 (23.2)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
8.8
Peak Power Rating, kW
38
RF Peak Voltage, Volts
1950
Jacket Spark, Volt RMS
8000
Inner Conductor dc Resistance,
1.57 (0.48)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
1.93 (0.59)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
LCF12-50J
LCF12-50JFN
LCF12-50JGR
38
www.rfsworld.com
Jacket
Standard
Flame Retardant
Standard, Gray
CELLFLEX Cable
APPLICATIONS
OEM jumpers, Microwave Hop feeds, GPS lines, Riser-rated InBuilding (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
5/8
STRUCTURE
Inner Conductor Material
Copper Tube
Diameter Inner Conductor, mm
6.6 (0.26)
(in)
Diameter Dielectric, mm (in)
15.5 (0.61)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
18.5 (0.73)
Conductor, mm (in)
Diameter over Jacket Nominal,
21.4 (0.84)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.37 (0.25)
Minimum Bending Radius, Single
90 (4)
Bend, mm (in)
Minimum Bending Radius,
190 (7)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
10.0 (7.4)
Flat Plate Crush Strength, N/mm
13.3 (70)
(lb/in)
Tensile Strength, N (lb)
1150 (259)
Recommended / Maximum Clamp
0.7 / 1.0 (2.25 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
88
Capacitance, pF/m (pF/ft)
76.0 (23.2)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
6.2
Peak Power Rating, kW
45
RF Peak Voltage, Volts
2110
Jacket Spark, Volt RMS
8000
Inner Conductor dc Resistance,
1.32 (0.40)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
1.43 (0.44)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
TRANSMISSION
LINE PRODUCTS
LCF58-50 Series
5/8 Low-Loss Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
LCF58-50J
LCF58-50JFN
Jacket
Standard
Flame Retardant
39
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCF78-50A Series
7/8 Low-Loss Foam Coax
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
7/8
STRUCTURE
Inner Conductor Material
Copper Tube
Diameter Inner Conductor, mm
9.3 (0.37)
(in)
Diameter Dielectric, mm (in)
21.5 (0.85)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
25.2 (0.99)
Conductor, mm (in)
Diameter over Jacket Nominal,
27.8 (1.09)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.51 (0.34)
Minimum Bending Radius, Single
120 (5)
Bend, mm (in)
Minimum Bending Radius,
250 (10)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
13.0 (9.6)
Flat Plate Crush Strength, N/mm
14 (80)
(lb/in)
Tensile Strength, N (lb)
1440 (324)
Recommended / Maximum Clamp
0.8 / 1.0 (2.75 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.185 (0.056)
Maximum Frequency, GHz
5
Peak Power Rating, kW
85
RF Peak Voltage, Volts
2910
Jacket Spark, Volt RMS
8000
Inner Conductor dc Resistance,
1.27 (0.39)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
1.05 (0.32)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
ORDERING INFORMATION
Model Number
LCF78-50JA-P*
LCF78-50JFNA-P*
LCF78-50JAGR
40
www.rfsworld.com
Jacket
Standard
Flame Retardant
Standard, Gray
CELLFLEX Cable
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
7/8
STRUCTURE
Inner Conductor Material
Copper Tube
Diameter Inner Conductor, mm
9.3 (0.37)
(in)
Diameter Dielectric, mm (in)
21.5 (0.85)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
25.2 (0.99)
Conductor, mm (in)
Diameter over Jacket Nominal,
27.8 (1.09)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.51 (0.34)
Minimum Bending Radius, Single
120 (5)
Bend, mm (in)
Minimum Bending Radius,
250 (10)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
13.0 (9.6)
Flat Plate Crush Strength, N/mm
14 (80)
(lb/in)
Tensile Strength, N (lb)
1440 (324)
Recommended / Maximum Clamp
0.8 / 1.0 (2.75 / 3.25)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.185 (0.056)
Maximum Frequency, GHz
5
Peak Power Rating, kW
85
RF Peak Voltage, Volts
2920
Jacket Spark, Volt RMS
8000
Inner Conductor dc Resistance,
1.27 (0.39)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
1.05 (0.32)
ohm/1000 m (Ohm/1000 ft)
See Installation, Operation and Storage Temperatures on page 28.
For premium return loss codes see page 29.
LCF78-50JA/JFNA PREMIUM
ATTENUATION AND AVERAGE POWER
Frequency Attenuation Attenuation
MHz
dB/100 m
dB/100 ft
0.5
0.0780
0.0238
1.0
0.110
0.0336
1.5
0.135
0.0412
2.0
0.156
0.0476
10
0.351
0.107
20
0.498
0.152
30
0.612
0.186
50
0.793
0.242
88
1.06
0.323
100
1.13
0.345
108
1.18
0.359
150
1.39
0.425
174
1.50
0.459
200
1.62
0.493
300
2.00
0.609
400
2.32
0.708
450
2.47
0.753
500
2.61
0.796
512
2.65
0.806
600
2.88
0.877
700
3.12
0.952
800
3.36
1.02
824
3.41
1.04
894
3.56
1.09
900
3.57
1.09
925
3.63
1.11
960
3.70
1.13
1000
3.78
1.15
1250
4.27
1.30
1500
4.72
1.44
1700
5.05
1.54
1800
5.21
1.59
2000
5.53
1.68
2100
5.68
1.73
2200
5.83
1.78
2400
6.12
1.86
3000
6.94
2.11
3500
7.57
2.31
4000
8.17
2.49
4900
9.19
2.80
5000
9.30
2.83
Average
Power kW
85.0
85.0
73.5
63.6
28.3
20.0
16.3
12.5
9.39
8.79
8.45
7.13
6.61
6.15
4.98
4.28
4.02
3.81
3.76
3.46
3.18
2.96
2.92
2.79
2.78
2.74
2.69
2.63
2.33
2.11
1.97
1.91
1.80
1.75
1.71
1.63
1.43
1.31
1.22
1.08
1.07
TRANSMISSION
LINE PRODUCTS
LCF78-50A Series
7/8 Premium Attenuation Low-Loss
Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
LCF78-50JA-A*
LCF78-50JFNA-A*
Jacket
Standard
Flame Retardant
41
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCFS114-50A Series
1-1/4 Low-Loss Foam Coax
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1-1/4
STRUCTURE
Inner Conductor Material
Copper Tube
Diameter Inner Conductor, mm
13.1 (0.52)
(in)
Diameter Dielectric, mm (in)
31.2 (1.23)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
36.0 (1.42)
Conductor, mm (in)
Diameter over Jacket Nominal,
39.0 (1.54)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.86 (0.58)
Minimum Bending Radius, Single
200 (8)
Bend, mm (in)
Minimum Bending Radius,
380 (15)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
35.0 (26.0)
Flat Plate Crush Strength, N/mm
24 (137)
(lb/in)
Tensile Strength, N (lb)
2490 (560)
Recommended / Maximum Clamp
1.0 / 1.2 (3.25 / 4.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.185 (0.056)
Maximum Frequency, GHz
3.6
Peak Power Rating, kW
176
RF Peak Voltage, Volts
4200
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
0.78 (0.24)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.67 (0.20)
ohm/1000 m (Ohm/1000 ft)
ORDERING INFORMATION
Model Number
LCFS114-50JA-P*
LCFS114-50JFNA-P*
LCFS114-50JAGR
42
www.rfsworld.com
Jacket
Standard
Flame Retardant
Standard, Gray
CELLFLEX Cable
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1-1/4
STRUCTURE
Inner Conductor Material
Copper Tube
Diameter Inner Conductor, mm
13.1 (0.52)
(in)
Diameter Dielectric, mm (in)
31.2 (1.23)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
36.0 (1.42)
Conductor, mm (in)
Diameter over Jacket Nominal,
39.0 (1.54)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
0.86 (0.58)
Minimum Bending Radius, Single
200 (8)
Bend, mm (in)
Minimum Bending Radius,
380 (15)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
35.0 (26.0)
Flat Plate Crush Strength, N/mm
24 (137)
(lb/in)
Tensile Strength, N (lb)
2490 (560)
Recommended / Maximum Clamp
1.0 / 1.2 (3.25 / 4.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.185 (0.056)
Maximum Frequency, GHz
3.6
Peak Power Rating, kW
181
RF Peak Voltage, Volts
4200
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
0.78 (0.24)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.67 (0.20)
ohm/1000 m (Ohm/1000 ft)
LCFS114-50JA/JFNA PREMIUM
ATTENUATION AND AVERAGE POWER
Frequency Attenuation Attenuation
MHz
dB/100 m
dB/100 ft
0.5
0.056
0.017
1.0
0.079
0.024
1.5
0.097
0.030
2.0
0.112
0.034
10
0.252
0.077
20
0.359
0.109
30
0.442
0.135
50
0.574
0.175
88
0.770
0.235
100
0.823
0.251
108
0.857
0.261
150
1.02
0.310
174
1.10
0.336
200
1.19
0.361
300
1.47
0.449
400
1.72
0.524
450
1.83
0.559
500
1.94
0.592
512
1.97
0.599
600
2.15
0.654
700
2.34
0.712
800
2.52
0.767
824
2.56
0.780
894
2.68
0.816
900
2.69
0.819
925
2.73
0.832
960
2.79
0.850
1000
2.85
0.870
1250
3.24
0.987
1500
3.87
1.18
1900
4.12
1.26
2000
4.25
1.30
2200
4.49
1.37
2500
4.85
1.48
3000
5.41
1.65
3300
5.73
1.75
Average
Power kW
181
140
114
98.6
43.7
30.7
25.0
19.2
14.3
13.4
12.9
10.8
10.0
9.31
7.50
6.42
6.02
5.68
5.61
5.14
4.72
4.38
4.31
4.12
4.10
4.04
3.96
3.87
3.41
2.85
2.68
2.60
2.45
2.28
2.04
1.93
TRANSMISSION
LINE PRODUCTS
LCFS114-50A Series
1-1/4 Premium Attenuation
Low-Loss Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
LCFS114-50JA-A*
LCFS114-50JFNA-A*
LCFS114-50JAGR-A*
Jacket
Standard
Flame Retardant
Standard, Gray
43
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCF158-50A Series
1-5/8 Low-Loss Foam Coax
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1-5/8
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
17.6 (0.69)
(in)
Diameter Dielectric, mm (in)
40.9 (1.61)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
46.5 (1.83)
Conductor, mm (in)
Diameter over Jacket Nominal,
50.3 (1.98)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
1.19 (0.80)
Minimum Bending Radius, Single
200 (8)
Bend, mm (in)
Minimum Bending Radius,
500 (20)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
46.0 (34.0)
Flat Plate Crush Strength, N/mm
25 (143)
(lb/in)
Tensile Strength, N (lb)
2500 (562)
Recommended / Maximum Clamp
1.2 / 1.5 (4.0 / 5.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
2.75
Peak Power Rating, kW
310
RF Peak Voltage, Volts
5600
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
1.26 (0.38)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.47 (0.14)
ohm/1000 m (Ohm/1000 ft)
ORDERING INFORMATION
Model Number
LCF158-50JA-P*
LCF158-50JFNA-P*
44
www.rfsworld.com
Jacket
Standard
Flame Retardant
CELLFLEX Cable
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
1-5/8
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
17.6 (0.69)
(in)
Diameter Dielectric, mm (in)
40.9 (1.61)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
46.5 (1.83)
Conductor, mm (in)
Diameter over Jacket Nominal,
50.3 (1.98)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
1.19 (0.80)
Minimum Bending Radius, Single
200 (8)
Bend, mm (in)
Minimum Bending Radius,
500 (20)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
46.0 (34.0)
Flat Plate Crush Strength, N/mm
25 (143)
(lb/in)
Tensile Strength, N (lb)
2500 (562)
Recommended / Maximum Clamp
1.2 / 1.5 (4.0 / 5.0)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
90
Capacitance, pF/m (pF/ft)
74.0 (22.5)
Inductance, H/m (H/ft)
0.185 (0.056)
Maximum Frequency, GHz
2.75
Peak Power Rating, kW
310
RF Peak Voltage, Volts
5600
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
1.26 (0.38)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.47 (0.14)
ohm/1000 m (Ohm/1000 ft)
LCF158-50JA/JFNA PREMIUM
ATTENUATION AND AVERAGE POWER
Frequency Attenuation Attenuation
MHz
dB/100 m
dB/100 ft
0.5
0.0435
0.0133
1.0
0.0617
0.0188
1.5
0.0756
0.0230
2.0
0.0874
0.0266
10
0.197
0.0601
20
0.281
0.0855
30
0.345
0.105
50
0.449
0.137
88
0.603
0.184
100
0.644
0.196
108
0.671
0.204
150
0.798
0.243
174
0.863
0.263
200
0.929
0.283
300
1.15
0.352
400
1.35
0.412
450
1.44
0.439
500
1.53
0.465
512
1.55
0.471
600
1.69
0.514
700
1.84
0.560
800
1.98
0.604
824
2.01
0.614
894
2.11
0.643
900
2.12
0.645
925
2.15
0.656
960
2.20
0.669
1000
2.25
0.685
1250
2.55
0.778
1500
2.84
0.865
1700
3.05
0.931
1800
3.16
0.96
2000
3.36
1.02
2100
3.46
1.05
2200
3.56
1.08
2400
3.74
1.14
2750
4.06
1.24
Average
Power kW
258
182
148
128
56.9
40.0
32.5
25.0
18.6
17.4
16.7
14.1
13.0
12.1
9.71
8.30
7.79
7.35
7.25
6.64
6.10
5.66
5.56
5.31
5.29
5.21
5.10
4.99
4.39
3.95
3.67
3.55
3.34
3.24
3.15
2.99
2.76
TRANSMISSION
LINE PRODUCTS
LCF158-50A Series
1-5/8 Premium Attenuation Low-Loss
Foam Coax
Standard Conditions:
For attenuation: VSWR 1.0, cable temperature 20 C (68 F).
For average power: VSWR 1.0, ambient temperature 40 C (104F),
inner conductor temperature 100 C (212 F). No solar loading.
ORDERING INFORMATION
Model Number
LCF158-50JA-A*
LCF158-50JFNA-A*
Jacket
Standard
Flame Retardant
45
www.rfsworld.com
TRANSMISSION
LINE PRODUCTS
CELLFLEX Cable
LCF214-50A Series
2-1/4 Low-Loss Foam Coax
APPLICATIONS
Main feed line, Riser-rated In-Building (JFN types, only)
GENERAL INFORMATION
Cable Type
Foam-Dielectric, Corrugated
Size
2-1/4
STRUCTURE
Inner Conductor Material
Corrugated Copper Tube
Diameter Inner Conductor, mm
20.8 (0.82)
(in)
Diameter Dielectric, mm (in)
49.0 (1.93)
Outer Conductor Material
Corrugated Copper
Diameter Copper Outer
56.1 (2.21)
Conductor, mm (in)
Diameter over Jacket Nominal,
59.9 (2.36)
mm (in)
MECHANICAL SPECIFICATIONS
Cable Weight, kg/m (lb/ft)
1.70 (1.14)
Minimum Bending Radius, Single
280 (11)
Bend, mm (in)
Minimum Bending Radius,
560 (22)
Repeated Bends, mm (in)
Bending Moment, Nm (lb-ft)
81.0 (60.0)
Flat Plate Crush Strength, N/mm
27.6 (150)
(lb/in)
Tensile Strength, N (lb)
2610 (587)
Recommended / Maximum Clamp
1.5 / 2.0 (5.0 / 6.6)
Spacing, m (ft)
ELECTRICAL SPECIFICATIONS
Impedance, Ohm
50 +/- 1
Velocity, percent
88
Capacitance, pF/m (pF/ft)
75.0 (22.9)
Inductance, H/m (H/ft)
0.190 (0.058)
Maximum Frequency, GHz
2.2
Peak Power Rating, kW
425
RF Peak Voltage, Volts
6520
Jacket Spark, Volt RMS
10000
Inner Conductor dc Resistance,
0.92 (0.28)
ohm/1000 m (ohm/1000 ft)
Outer Conductor dc Resistance,
0.31 (0.09)
ohm/1000 m (Ohm/1000 ft)
ORDERING INFORMATION
Model Number
LCF214-50JA-P*
LCF214-50JFNA-P*
46
www.rfsworld.com
Jacket
Standard
Flame Retardant