You are on page 1of 19

AMOS LIGHT TO ANOC 1st Line

Amos Light Test for ANOC 1st Line V2

20-02-2014

Document Controls
Version

0.1

Notes

Author

Draft for review


Revision 2

Joo Loiro
Joo Loiro

Date

Approval
Date

18/03/14
08/04/14

Description
This document serves to elucidate the Users ANOC 1st LINE on the use of AMOS tool.

Contents
1.

AMOS Light ................................................................................................................................................ 3


1.1

Initializing Amos ............................................................................................................................................... 5

1.2

Alarms ................................................................................................................................................................... 6

1.3

Hardware ........................................................................................................................................................... 10

1.4

Cells..................................................................................................................................................................... 13

1.5

Software ............................................................................................................................................................ 14

1.6

Transmission ................................................................................................................................................... 15

1.7

Stats .................................................................................................................................................................... 18

Classification C2

Page 2 of 19

Amos Light Test for ANOC 1st Line V2

1.

20-02-2014

AMOS Light

The present demonstration, was made on RBS


In the end, is expected to know check:

Classification C2

Alarms

Hardware

Cells

Software

Transmission

Stats

Page 3 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Operations of 1st line

Actions on RBS

TYPE
ALARMS

TASKS

STATE COMMAND

ALARM CHECK
ALARM CONFIGURATION
ALARM TESTING
ALARM LOG

alt; ala
get . Alarm
alt; ala
lga

CABINET
CHECK BOARDS
LOCK AND UNLOCK
BOARDS

get 0
Cabx & Cab

RADIO LINKS

hget radio; get . Commcontext

LIST CV
SET CV
RESTART

cvls
cvset <Cv name>
acc 0 manualrestart

SYNCHRONISM
STATUS
TYPE OF TRANSMISSION
CONFIGURATION
TESTING

get 10
st E1
get . Iub
ATM: stv ; IP: get . Gigabit -> get < Mo name >
IP & ATM: pdiff e1; ATM: acc .*vcltp=vc
eteloopback

SITE
IUB

pmr and pick the following options


Pget iub

HARDWARE

lbl board & ldeb board

CELLS
SOFTWARE

TRANSMISSION

STATS

Classification C2

Page 4 of 19

Amos Light Test for ANOC 1st Line V2

1.1

20-02-2014

Initializing Amos

Please open the Common Explorer and pick a node.

And Open a Amos session.

Classification C2

Page 5 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Loading all Managed Objects that match a specified word, and all the children of
these Managed Objects

To load all Managed Objects that match a specified word, and all the children of these
Managed Objects, use the following command:

Lt all:

1.2

Alarms

Usefull Commands:
ALT: To print all alarms chronologically.

Classification C2

Page 6 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

ALA: To print the active alarm list with detailed information on the alarm.

Get . Alarm: To Print the configuration of external alarm.

Classification C2

Page 7 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

If we want to configure any alarm we can do for example:

The following command print every external alarms with the proxy number.
pr Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice

Now we can do the command get with the proxy number. In this case, is Proxy 503
Get 503 Proxi ID

Classification C2

Page 8 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

If the purpose, is to change any parameter from the configuration of external alarm. The Mo must
be locked. To lock an MO, could be used a Set command to affect the administrativeState value.
For example:
Set <Mo name or Proxy ID> <attribute> <value>
set Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1 administrativeState 0
or

set 503 administrativeState 0


An easy way to do it, is using the following commands.
Lbl/bl to lock
lbl <Mo name or Proxy ID>
lbl Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1
or

lbl 503
Ldeb/deb to unlock
ldeb <Mo name or Proxy ID>
ldeb Equipment=1,AuxPlugInUnit=1,XalmDeviceGroup=1,AlmDeviceSet=1,AlmDevice=1
or

ldeb 503
after this mo locked, may proceed with the changes. Please dont forget, to unlock the alarm at
the end. If not the alarms will stay inhibit.
Lga: Displays all of the past alarms.
The password of node is wireless

Classification C2

Page 9 of 19

Amos Light Test for ANOC 1st Line V2

1.3

20-02-2014

Hardware

Usefull Commands:
Get 0: Print cabinet info like, cabinet type and serial.

Cab: cab - Prints MP/BP HW info and LED status, MP temperature, and COREMGR status.

Classification C2

Page 10 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Cabx: Same as cab plus LED and HW info for the XP boards.

Classification C2

Page 11 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Lbl [s] & ldeb: Lock or soft-lock & Unlock MO(s).


Lbl/bl to lock.
On this example we use a ASC
lbl <Mo name or Proxy ID>
lbl Equipment=1,SectorAntenna=2,AuxPlugInUnit=1
or

lbl 177

Ldeb/deb to unlock
ldeb <Mo name or Proxy ID>
ldeb Equipment=1,SectorAntenna=2,AuxPlugInUnit=1
or

ldeb 177

Classification C2

Page 12 of 19

Amos Light Test for ANOC 1st Line V2

1.4

20-02-2014

Cells

Usefull Commands:
Hget radio Print horizontally, one line per sector and carrier (instead of one line per
attribute)

Get . commcontext Display all of the established radio links.

Classification C2

Page 13 of 19

Amos Light Test for ANOC 1st Line V2

1.5

20-02-2014

Software

Usefull Commands:
Cvls Displays both the current CV information and CV list.

Cv startable, CV loaded, CV Executing and the last CV Created.

Upgrade software available on RBS.

Configuration version Name

Sofware version

Cvset Set a CV as startable.

Classification C2

Page 14 of 19

Responsible fro the CV

Amos Light Test for ANOC 1st Line V2

20-02-2014

Acc 0 manualrestart Restart RBS.

After restart, RBS will be start on CV NTP_new_OK

1.6

Transmission

Usefull Commands:
Get Synch Displays the sync Information.

On this output is printed the state of the sync, his reference.and if its stable or not.
St E1: Check the status of the E1.

Classification C2

Page 15 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Get iub: Print the Iub interface.

Default gateway

Type of IUB
Configuration:
ATM:
Stv Display state, user, and bandwidth usage for ATM ports.

Get ima Display the configuration of the IMA Group

Required Number of Links

Classification C2

Page 16 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

IP: Get Giga Display the configuration of the gigabit port.

Testing:
ATM: Acc .*vcltp=vc eteloopback This could be used to check if there was a
transmission problem.

ATM&IP: pdiff e1 Print incrementation of E1 PM attributes.

Classification C2

Page 17 of 19

Amos Light Test for ANOC 1st Line V2

1.7

20-02-2014

Stats

Usefull Commands:
Pmr produce PM KPI reports

Option 1 RSSI Whole Period

Rssi Value should be between -100 & -110

Classification C2

Page 18 of 19

Amos Light Test for ANOC 1st Line V2

20-02-2014

Option 2 RSSI Rop by Rop (Each rop is equal to 15 minutes)

Option 7 IubDataStrams Performance