You are on page 1of 9

"A" Series Piston Pumps

Variable Displacement-Single Pumps


Solenoid Two Pressure Control Type
A16 / A22 / A37 / A56 / A70 / A90 / A145

PISTON
PUMPS

Specifications
Graphic Symbol

PH

Output Flow

PL

Performance Characteristics

M
O

SOL
"OFF"

SOL
"ON"

PL
Pressure

PH

Specifications
Model Numbers

A16--R-02--K-32

A22--R-02--K-32
A37--R-02--K-32
A56--R-02--K-32
A70-R02S-60
A90-R02S-60

A145-R02S-60

Operating Pres.
MPa (PSI)

Geometric
Displacement
cm3/rev
(cu. in. /rev)

Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)

Rated

Minimum
Adj. Pres.
1
Intermittent MPa (PSI)

50

A120
AC
A200

A240
D12
DC
D24
(K Series)
D48
ACDC R100
Rectified R200

60
50
60
50
60
50
60

50 /60

Flange
Mtg.

Foot
Mtg.

4 (.244)

16 (2320)

21 (3050)

1.2 (170)

1800

600

24.5 (54.0) 26.7 (58.9)

6 (.366)

16 (2320)

16 (2320)

1.2 (170)

1800

600

24.5 (54.0) 26.7 (58.9)

36.9 (2.25)

10 (.61)

16 (2320)

21 (3050)

1.2 (170)

1800

600

36 (79.4) 40.3 (88.9)

56.2 (3.43)

12 (.73)

16 (2320)

21 (3050)

1.2 (170)

1800

600

43 (94.8) 47.3 (104)

70.0 (4.27)

30 (1.83)

25 (3630)

25 (3630)

2 (290)

1800

600

63.5 (140) 75.5 (166)

91.0 (5.55)

56 (3.42)

25 (3630)

25 (3630)

2 (290)

1800

600

80.5 (178) 101 (223)

145 (8.85)

83 (5.06)

25 (3630)

25 (3630)

2 (290)

1800

600

97.5 (215) 122.5 (270)

2. When operating the pump exceeding the rated pressure, operating


conditions are restricted. Refer to page 6 for the details.

Voltage (V)
Current & Power at Rated Voltage
Source Serviceable Inrush
Holding
Power
Rating
Range
(A)
(A)
(W)
80 -110
0.51
2.42
100
0.37
2.14
100
90 -120
0.44
2.35
110
96 -132
0.42
2.02
120
108 -144
0.31
1.78
160 -220
0.25
1.21
200
0.19
1.07
200
180 - 240
0.22
1.18
220
192 - 264
0.21
1.01
240
216 - 288
0.15
0.89
10.8 - 13.2
2.45
12
21.6 - 26.4
1.23
24
29
43.2 - 52.8
0.61
48
90 - 110
0.33
100
29
180 - 220
0.16
200

Inrush current in the above table shows rms values at maximum stroke.

No.28

Min.

15.8 (.964)

Solenoid Ratings

A100

Max.

Approx. Mass
kg (lbs.)

22.2 (1.355)

1. Whenever setting pressure, make sure the full cut-off pressure never
exceeds the maximum intermittent pressure.

Electric Coil Frequency


Source Type
(Hz)

Shaft Speed Range


r/min

"A" Series Piston Pumps


Solenoid Two Pressure Control Type
A16 / A22 / A37 / A56 / A70 / A90 / A145
Model Number Designation

PISTON
PUMPS

Model Number Designation

A16
Series
Number

-F

-R

-02

-S

-K

-A100

-32

Mounting

Direction of
Rotation

Control
Type

Port
Position

Shaft
Extension

Coil Type of
Solenoid Valve

Design
Number

Design
Std.

A16
(15.8 cm3/rev)
A22
(22.2 cm3/rev)
A37
(36.9 cm3/rev)

F:
Flange
Mtg.
L:
Foot
Mtg.

Viewed from
Shaft End

R:
Clockwise
(Normal)

32
02:
Solenoid Two
Prsuure Control
Type

None:
Axial Port

S:
Side Port

A56
(56.2 cm3/rev)

A70
Series
Number
A70
(70 cm3/rev)
A90
(91.0 cm3/rev)
A145
(145 cm3/rev)

AC
A100,A120
A200,A240

DC
K:
Keyed Shaft D12,D24
D48
(ACDC Rectified)
R100,R200

32
Refer to

32

32

-F

02

A100

-60

Mounting

Direction of
Rotation

Control
Type

Port
Position

Coil Type of
Solenoid Valve

Design
Number

Design
Std.

F:
Flange Mtg.
L:
Foot Mtg.

Viewed from
Shaft End
R:
Clockwise
(Normal)

02:
Solenoid Two
Prsuure Control
Type

1. Available to supply pump with anti-clockwise rotation. Consult


Yuken for details.

AC
A100,A120
A200,A240
S:
Side Port

DC
D12,D24
D48
(ACDC Rectified)
R100,R200

60

60

Refer to

60

3. Design Standards: None ........... Japanese Standard "JIS"


80 ............... European Design Standard
90 ............... N. American Design Standard

2. The axial port is not available to the N. American Design Standard of


A37 and A56 series.

Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 10 to 16.

Pipe Flange Kit


For pipe flange, refer to form of pressure compensator type on page 7.

No.29

"A" Series Piston Pumps


A16 / A22--R-02

PISTON
PUMPS

Installation Drawing
Axial Port Type
Flange Mtg.: A16-F-R-02-K--32/3290
A22-F-R-02-K--32/3290

172
(6.77)
Pilot Port "PP1"
"E" Thd.

23
(.91)

106
(4.17)
130
(5.12)
188
(7.40)

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

3(.12)

R14(R.55)
95(3.74) Dia.

A16-F-R-02-K--3280
A22-F-R-02-K--3280

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 in.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
135
80.1
(5.31)
(3.15)
d
53
(2.09)

161
(6.34)

Flow Adj. Screw


5(.20) Hex. Soc.

Suction Port
19(.75) Dia.

22.2(.874)
65
(2.56)

47.6
(1.874)

DEC.

"F" Thd. 17(.67) Deep


8 Places
Discharge Port
19(.75) Dia.

View Arrow X

Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised

177
(6.97)
195.5
(7.70)

12
(.47)
12
(.47)

Lock Nut
17(.67) Hex.

16
(.63)

18(.71)

96
(3.78)

19.05(.7500)
19.02(.7488) Dia.
21.24(.836)
21.08(.830)
82.55(3.250)
82.50(3.248) Dia.

273.5
(10.77)
145
(5.71)
117
(4.61)
62
(2.44)

Lock Nut
14(.55) Hex.

Fully Extended
2
256.5(10.10)
Pilot Port "PP2"
141.5
"E" Thd.
(5.37)
90
138.5
77
(3.54)
(5.45)
(3.03)
44.5(1.75)
Electrical Conduit
112
3
53
Connection
(4.41)
(.12) (2.09)
"D" Thd. (Both Ends)
59
6.5
(2.32) (.26)
1
Filling Port
26.5
[22(.87) Hex. Head Plug Furnished]
"PP1"
(1.04)
Drain Port
"PP2"
"C" Thd.
4.79(.1886)
25
4.76(.1874)
(.98)

mm (IN.)

Model Numbers

A16/A22-F-R-02-K-A-

194 (7.64)

182. (7.17)

39 (1.54)

3280

205 (8.07)

193 (7.60)

39 (1.54)

A16/A22-F-R-02-K-D-

208 (8.19)

186.2 (7.33)

53 (2.09)

For other dimensions, refer to 32/3290 design.


1. Install the pump so that the "Filling Port" is at the
top.
2. The pilot port provided is for connecting a control
valve, if multistage pressure control is required.

Model Numbers
A16/A22-F-R-02-K--32

A16/A22-F-R-02-K--3280

A16/A22-F-R-02-K--3290

"C" Thd.

"D" Thd.

Rc 3/8

G 1/2

Rc 1/4
1/4 BSP. Tr

3/8 BSP.F
3/8 NPT

"E" Thd.

1/2 NPT

1/4 NPT

"F" Thd.
M10
3/8-16 UNC

DIMENSIONS IN MILLIMETRES (INCHES)


Side Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure compensator


model. Refer to page 18 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 18 for the dimensions of mounting bracket.

No.30

"A" Series Piston Pumps


A37--R-02

PISTON
PUMPS

Installation Drawing
Side Port Type
Flange Mtg. : A37-F-R-02-S-K-32/3290

32(1.26)

14
(.55)
30.2
12
(1.189) (.47)
178.5
(7.03)

Pilot Port "PP1"


"E" Thd.

R14(R.55)
120(4.72) Dia.
146.5
(5.75)
174
(6.85)
202
(7.95)

A37-F-R-02-S-K-3280

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
77.1
158
(3.04)
(6.22)
d
50
(1.97)

165
(6.50)

Flow Adj. Screw


5(.20) Hex. Soc.

b
86
(3.39)

"F" Thd. "H" Deep


4 Places

DEC.

6.38(.2512)
6.35(.2500)

105
(4.13)

Front Side : Discharge Port 32(1.26) Dia.


Rear Side : Suction Port 32(1.26) Dia.

26
13
(.51) (1.02)
Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
6(.24)
Works at Solenoid
Energised

Electrical Conduit
Connection
"D" Thd. (Both Ends)

Drain Port
"C" Thd.

22.23(.8752)
22.20(.8740) Dia.
25.01(.985)
24.85(.978)

289.5
(11.40)
149
(5.87)
121
(4.76)
68
(2.68)
58.7
(2.311)

"PP2"

Filling Port
[22(.87) Hex. Head Plug Furnished]

(2.91)
6
50
(.24) (1.97)

181
(7.13)
199.5
(7.85)

"PP1"

25
(.98)

Lock Nut
14(.55) Hex.

Pilot Port "PP2"


"E" Thd.
74

101.60(4.000)
101.55(3.998) Dia.

Lock Nut
17(.67) Hex.

Fully Extended
279.5(11.00)
164.5
(6.48)
161.5
90
(6.36)
(3.54)
59(2.32)
135
(5.31)
9.5
77
(3.03)
(.37)
30(1.18)

86
(3.39)

Surface of
Suction Port

Surface of
Discharge Port

mm (IN.)

Model Numbers

View Arrow X

A37-F-R-02-S-K-A-3280

A37-F-R-02-S-K-D-3280
A37-F-R-02-S-K-R-3280

1. Install the pump so that the "Filling Port" is at the top.


2. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Model Numbers
A37-F-R-02-S-K--32

A37-F-R-02-S-K--3280

A37-F-R-02-S-K--3290

198 (7.80)

186 (7.32)

39 (1.54)

209 (8.23)

197 (7.76)

39 (1.54)

212 (8.35)

190.2 (7.49)

53 (2.09)

For other dimensions, refer to 32/3290 design.

"C" Thd.

"D" Thd.

"E" Thd.

Rc 1/2

G 1/2

Rc 1/4
1/4 BSP. Tr

1/2 BSP.F
1/2 NPT

1/2 NPT

1/4 NPT

"F" Thd.

"H" mm (IN.)

M10

19 (.75)

7/16-14 UNC

20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)


Axial Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure


compensator model. Refer to page 19 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 19 for the dimensions of mounting bracket.

No.31

"A" Series Piston Pumps


A56--R-02

PISTON
PUMPS

Installation Drawing
Side Port Type
Flange Mtg.: A56-F-R-02-S-K--32/3290
Fully Extended
292(11.50)
177
(6.97)
90
174
(3.54)
(6.85)
62(2.44)
147.5
(5.81)
50.5(1.99) 9.5(.37)

Filling Port 1
[22(.87) Hex. Head Plug Furnished]
Drain Port 2
"C" Thd. (Both Sides)

43.5(1.71)
"PP1"
"PP2"

35.32(1.391)
35.14(1.383)
101.60(4.000)
101.55(3.999) Dia.

R14(R.55)
120(4.72) Dia.

146
(5.75)
174
(6.85)
232
(9.13)

"F" Thd. "H" Deep


4 Places
3

Pilot Port "PP1"


"E" Thd.
Pressure Adj. Screw (PL)
14(.55) Hex.
Works at Solenoid
INC.
De-energised

26
13
(.51) (1.02)
6(.24)

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
170.5
(6.71)

190
(7.48)

Flow Adj. Screw


5(.20) Hex. Soc.

A56-F-R-02-S-K--3280

50
(1.97)

DEC.

77.1
(3.04)

100
(3.94)
Surface of
Suction Port

12
30.2
(1.189)
(.47)
207
(8.15)

31.75(1.2500)
31.70(1.2480) Dia.

Front Side : Discharge Port 30(1.18) Dia.


Rear Side : Suction Port 35(1.38) Dia.

Pressure Adj.
Screw (PH) INC.
14(.55) Hex.
Works at Solenoid
Energised

49 4
(1.93)

14
(.55)

322.5
(12.70)
174
(6.85)
146
(5.75)
90
(3.54)
77
(3.03)
58.7(2.311)

41
7.97(.3138) (1.61)
7.94(.3126)

40
(1.57)

Electrical Conduit
Connection
"D" Thd. (Both Ends)

206
(8.11)
224.5
(8.84)

Lock Nut
14(.55) Hex.

Pilot Port "PP2"


"E" Thd.
74
(2.91)
6
50
(.24) (1.97)

25
(.98)

Lock Nut
17(.67) Hex.

100
(3.94)
Surface of
Discharge Port

View Arrow X
mm (IN.)

Model Numbers
1. Install the pump so that the "Filling Port" is at the top.
2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (3280 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

A56-F-R-02-S-K-A-3280

A56-F-R-02-S-K-D-3280
A56-F-R-02-S-K-R-3280

223 (8.78)

211 (8.31)

39 (1.54)

234 (9.21)

222 (8.74)

39 (1.54)

237 (9.33)

215.2 (8.47)

53 (2.09)

For other dimensions, refer to 32/3290 design.

4. Dimensions show surface of drain port.

Model Numbers
A56-F-R-02-S-K--32

A56-F-R-02-S-K--3280

A56-F-R-02-S-K--3290

"C" Thd.

"D" Thd.

Rc 3/4

G 1/2

Rc 1/4
1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

"E" Thd.

1/2 NPT

1/4 NPT

"F" Thd.

"H" mm (IN.)

M10

19 (.75)

7/16-14 UNC

20 (.79)

DIMENSIONS IN MILLIMETRES (INCHES)


Axial Port Type

Foot Mounting Type

Port mounting dimensions are the same as those of pressure compensator


model. Refer to page 20 for port mounting dimensions.

Mounting bracket is common to that of pressure compensator model.


Refer to page 20 for the dimensions of mounting bracket.

No.32

"A" Series Piston Pumps


A70-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A70-FR02S-60/6090

27(1.06) Dia.
Spotface
(From Rear)
4 Places

40
(1.57)

19.5
(.77)
16
(.63)
18
(.71)

26.2
(1.031)

"F" Thd.
17(.67) Deep
4 Places

31.75(1.250)
31.70(1.248) Dia.
35.32(1.391)
35.14(1.383)
127.00(5.000)
126.95(4.998) Dia.

52.4
(2.063)

90
(3.54)

7.97(.3138)
7.94(.3126)

202.5
(7.97)
186.5
(7.34)
18(.71)
14(.55)

9.5(.37)

Discharge Port
26(1.02) Thd.

95
95
(3.74) (3.74)
73
73
(2.87) (2.87)
10
(.39)

Surface of
Discharge Port
4
Surface of
Drain Port

35(1.38) Dia.
Spotface
(From Rear)
2 Places

114.4
(4.508)
134
(5.28)
181
(7.13)
211
(8.31)

246.5
(9.70)

INC.

Pilot port "PP1"


"E" Thd.
10
(.39)

3
1

Electrical Conduit
Connection
"D" Thd. (Both Ends)

Eye Bolt
M10

Filling Port
[22(.87) Hex. Head Plug Furnished]

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Suction Port
38(1.50) Dia.
69.9
(2.752)

90
Pressure Adj. Screw (PH)
(3.54)
14(.55) Hex.
66
Works at Solenoid
(2.60)
Energised

118
(4.65)

Drain Port
"C" Thd. (Both Sides)
62(2.44)

Pilot Port 3
"PP2" "E" Thd.
Surface of
Suction Port
Surface of 4
Drain Port

218.5
(8.60)
237
(9.33)

114.4
(4.508)
180
(7.09)

Fully Extended
354.5(13.96)
239
(9.41)
90
236
(9.29)
(3.54)
209.5
(8.25)
65
(2.56)

Flow Adj. Screw


17(.67) Hex.
DEC.
5

Case Drain Port


5(.20) Hex. Soc.

View Arrow X

35.7
(1.406)
246.5
(9.70)

"H" Thd. "J" Deep


4 Places

View Arrow Y
Model Numbers

"C" Thd.

"D" Thd.

"E" Thd.

Rc 3/4

G 1/2

Rc 1/4

A70-FR02S-60

A70-FR02S-6080

1/4 BSP. Tr

3/4 BSP.F

A70-FR02S-6090

3/4 NPT

1/4 NPT

1/2 NPT

A70-FR02S-6080

"F" Thd.

"H" Thd.

"J" mm (IN.)

M10

M12

19 (.75)

7/16-14 UNC

1/2-13 UNC

21 (.83)

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
232.5
93.1
(9.15)
(3.67)
d
66
(2.60)

4. Dimensions show surface of drain port.

5. Case drain port is available for use when draining hydraulic


fluid from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A70-FR02SA-6080
A70-FR02SD-6080
A70-FR02SR-6080

mm (IN.)
a

236 (9.29)

224 (8.82)

39 (1.54)

247 (9.72)

235 (9.25)

39 (1.54)

250 (9.84)

228.2 (8.98)

53 (2.09)

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 21 for the dimensions
of mounting bracket.

For other dimensions, refer to 60/6090 design.

No.33

"A" Series Piston Pumps


A90-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg.: A90-FR02S-60/6090
Surface of
Discharge Port

Drain Port
"C" Thd. (Both Sides)

Surface of
Drain Port

263.5
95
(10.37)
(3.74)
23(.91)
119.5
(4.70)
13(.51)

Pilot Port
"PP2" "E" Thd.

Surface of
Suction Port

105
105
(4.13) (4.13)
68 68
(2.68) (2.68)
2.5 53.5
(.1) (2.11)

Surface of
Drain Port

9.56(.3764)
9.53(.3752)

212
(8.35)
196
(7.72)

113
(4.45)
22
(.87)
23
(.91)

30.2
(1.189)
"F" Thd.
"J" Deep
4 Places

270
(10.63)

38.10(1.500)
38.05(1.498) Dia.
42.36(1.668)
42.18(1.661)
152.40(6.000)
152.35(5.998) Dia.

58.7
(2.311)
Discharge Port
32(1.26) Dia.

161.6
(6.362)
127
180
(7.09)
(5.00)
227
(8.94)
246.5
(9.70)

63(2.48)

21.5 (.85) Dia. Through


39(1.54) Dia. Spotface
(From Rear)
4 Places

R22(R.87)

161.6
(6.362)

Case drain Port


5(.20) Hex. Soc.

Pilot Port "PP1"


"E" Thd.

22.5
(.89)

Eye Bolt
M10
1

Filling Port
[27(1.06) Hex. Head Plug Furnished]

2.5
(.10)

Fully Extended
379(14.92)
260.5
90
(10.26)
(3.54)

Pressure Adj. Screw (PL)


14(.55) Hex.
Works at Solenoid
INC.
De-energised

Electrical Conduit Connection


"D" Thd. (Both Ends)

77.8
(3.063)
88
(3.46)
168
(6.61)
196
(7.72)

Pressure Adj. Screw (PH)


14(.55) Hex.
Works at Solenoid INC.
Energised

Flow Adj. Screw


17(.67) Hex. Soc.

Suction Port
48(1.89) Dia.

DEC.

View Arrow X

42.9
(1.689)
270
(10.63)

"H" Thd. "K" Deep


4 Places

View Arrow Y
Model Numbers

"C" Thd.

"D" Thd.

"E" Thd.

Rc 3/4

G 1/2

Rc 1/4

A90-FR02S-60

A90-FR02S-6080

A90-FR02S-6090

1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

1/4 NPT

1/2 NPT

A90-FR02S-6080

"F" Thd.

"H" Thd.

"J" mm (IN.) "K" mm (IN.)

M10

M12

19 (.75)

19 (.75)

7/16-14 UNC

1/2-13 UNC

20 (.79)

21 (.83)

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
56.6(2.23)
257.5
(10.14)
53.5
d
(2.11)

4. Dimensions show surface of drain port.

5. Case drain port is available for use when draining hydraulic fluid from pump casing.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A90-02FRSA-6080
A90-02FRSD-6080
A90-02FRSR-6080

mm (IN.)
a

245 (9.65)

233 (9.17)

39 (1.54)

256 (10.08)

244 (9.61)

39 (1.54)

259 (10.20)

237.2 (9.34)

53 (2.09)

For other dimensions, refer to 60/6090 design.

No.34

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 22 for the dimensions
of mounting bracket.

"A" Series Piston Pumps


A145-FR02

PISTON
PUMPS

Installation Drawing
Flange Mtg. : A145-FR02S-60/6090
Surface of
Discharge Port

112
(4.41)
23(.91)

89
(3.50)

Surface of
Drain Port

13(.51)

Drain Port "C" Thd.


(Both Sides)

Pilot Port
"PP2" "E" Thd.

Surface of
Drain Port
11.14(.4386)
11.11(.4374)

21.5(.85) Dia. Through


39(1.54) Dia. Spotface
(From Rear)
4 Places

299.5
(11.79)

Eye Bolt
M10
3

198
(7.80)
248.5
(9.78)
228.6
(9.000)

110
(4.33)

Case Drain Port


5(.20) Hex. Soc.

24
(.94)
26
(1.02)

R22(R .87)

228.6
(9.000)
273
(10.75)

281.5
(11.08)

Y
141
(5.55)

44.45(1.750)
44.40(1.748) Dia.
49.39(1.944)
49.21(1.937)
152.40(6.000)
152.35(5.998) Dia.

58.7
(2.311)
Discharge Port
32(1.26) Dia.
30.2
(1.189)

Surface of
Suction Port

70(2.76)

"F" Thd.
"J" Deep
4 Places

112
112
(4.41) (4.41)
72 72
(2.83) (2.83)
12
(.47)

214
(8.43)

Fully Extended
400.5(15.77)
285
(11.22)
255.5
(10.06)

Electrical Conduit
Connection
"D" Thd. (Both Ends)
90
(3.54)

Pressure Adj. Screw (PH)


Pilot Port "PP1"
Filling Port
68
14(.55) Hex.
[27(1.06) Hex. Head Plug Furnished]
"E" Thd.
(2.68)
Works at Solenoid
INC.
Energised
12
(.47)
Pressure Adj. Screw (PL)
14(.55) Hex.
Works at Solenoid INC.
De-energised

77.8
(3.063)

Suction Port
48(1.89) Thd.

230
(9.06)

Flow Adj. Screw


17(.67) Hex. Soc.

"H" Thd. "K" Deep


4 Places

DEC.

42.9
(1.689)
299.5
(11.79)

View Arrow X

View Arrow Y
Model Numbers
A145-FR02S-60

A145-FR02S-6080

A145-FR02S-6090

"C" Thd.

"D" Thd.

Rc 3/4

G 1/2

"E" Thd.
Rc 1/4
1/4 BSP. Tr

3/4 BSP.F
3/4 NPT

1/4 NPT

1/2 NPT

A145-FR02S-6080

92(3.62)

"J" mm (IN.) "K" mm (IN.)

M10

M12

19 (.75)

19 (.75)

7/16-14 UNC

1/2-13 UNC

20 (.79)

21 (.83)

4. Dimensions show surface of drain port.

68
(2.68)

5. Case drain port is available for use when draining hydraulic


fluid from pump casing.
b

"H" Thd.

1. Install the pump so that the "Filling Port" is at the top.


2. Use either port of two drain ports at your option.
Keep the remaining port plugged. Note that on the European
Design Standard (6080 Design), only the left side, as viewed
from the shaft end, of the drain port is machined.
3. The pilot port provided is for connecting a control valve, if
multistage pressure control is required.

Cable Departure
Cable Applicable:
Outside Dia. 8-10mm(.31-.39 IN.)
Conductor Area Not Exceeding 1.5mm2(.002 Sq. IN.)
278
(10.94)

"F" Thd.

DIMENSIONS IN
MILLIMETRES (INCHES)
Model Numbers
A145-FR02SA-6080
A145-FR02SD-6080
A145-FR02SR-6080

mm (IN.)
a

247 (9.72)

235 (9.25)

39 (1.54)

258 (10.16)

246 (9.69)

39 (1.54)

261 (10.28)

239.2 (9.42)

53 (2.09)

Foot Mounting Type


Mounting bracket is common to that of pressure
compensator model. Refer to page 23 for the dimensions
of mounting bracket.

For other dimensions, refer to 60/6090 design.

No.35

"A" Series Piston Pumps


Variable Displacement-Single Pumps
Pressure Compensator with Unloading Type
A16 / A22 / A37 / A56 / A70 / A90 / A145

PISTON
PUMPS

Specifications

Performance Characteristics

Output Flow

Graphic Symbol

SOL
"OFF"

SOL
"ON"

M
O

Pressure

Specifications
Shaft Speed
Range
r/min

Model Numbers

Geometric
Displacement
cm3/rev
(cu. in. /rev)

Minimum
Adj. Flow
cm3/rev
(cu. in. /rev)

Rated

Intermittent

Max.

Min.

A16--R-03--K--32

15.8
(.964)

4
(.244)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A22--R-03--K--32

22.2
(1.355)

6
(.366)

16
(2320)

16
(2320)

1.2
(170)

1800

600

A37--R-03--K--32

36.9
(2.25)

10
(.61)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A56--R-03--K--32

56.2
(3.43)

12
(.73)

16
(2320)

21
(3050)

1.2
(170)

1800

600

A70-R03S-K-60

70.0
(4.27)

30
(1.83)

25
(3630)

25
(3630)

1.2
(170)

1800

600

A90-R03S-K-60

91.0
(5.55)

56
(3.42)

25
(3630)

25
(3630)

1.2
(170)

1800

600

A145-R03S-K-60

145
(8.85)

83
(5.06)

25
(3630)

25
(3630)

1.2
(170)

1800

600

Consult YUKEN for details.

No.36