Professional Documents
Culture Documents
Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.
#5
#5
#5
#5
#5
(h2=h1)
(L2=L1)
Bar Spacing:
v = 18.00 in
w = 18.00 in
x = 18.00 in
y = 9.00 in
z = 18.00 in
(z=w)
BAR
NUMBER
MARK
LENGTH
WEIGHT
(LBS.)
TYPE
INC.
D
WINGWALLS
2
SERIES
of 13
4
54
5'- 10''
TO
10'- 4''
10'- 4''
6'- 0''
WW504
WW505
WW506
2
SERIES
of 13
16
4
SERIES
of 3
14
4
2
5'- 10''
TO
10'- 4''
17'- 8''
5'- 11''
TO
17'- 8''
3'- 11''
20'- 7''
1'- 6''
V501
W501
Z501
30
30
34
F501
F502
12
16
2
SERIES
of 7
4
SERIES
of 7
1
X501
X502
Y501
WW501
WW502
WW503
220
STR.
44
341
STR.
1
220
STR.
295
STR.
148
STR.
58
86
4
2
3
4
7'- 8''
7'- 8''
8'- 2''
240
240
290
STR.
STR.
5
6'- 11''
5'- 5''
11'- 6''
TO
17'- 11''
16'- 4''
TO
19'- 6''
11'- 6''
87
91
STR.
STR.
215
524
STR.
0'-
0'- 6''
5'- 8''
0'-
5'0'- 10''
2'- 5''
0'- 10''
0'- 1 3/4''
4'- 4''
0'- 1 3/4''
2'- 1/1''
17'- 8''
2'- 4 5/4''
F503
F504
3'- 7''
1'- 2''
1'- 9''
1'- 9''
6'- 2 9/4''
TO
12'- 2 3/2''
1'-
0'6'- 2 9/4''
F505
F506
F507
F508
SERIES
2
2
SERIES
2
7
2
TO
12'- 6''
16'- 4''
TO
16'- 10''
5'- 11''
9'- 0''
26
70
STR.
44
19
1
STR.
1'- 9''
1'- 9''
TO
7'- 7/1''
0'3'- 8''
2'- 4''
FORESLOPE WALL
FS501
FS502
FS503
6
10
10
9'- 0''
4'- 5''
4'- 11''
TOTAL
57
47
52
3,418
STR.
5
7
0'-
1'- 10''
1'- 10''
0'- 11''
0'- 11''
2'- 5''
INC.
9/2''
9/2''
8 5/8''
3/4''
5 1/8''
4 7/4''
6/1''
Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.
#5
#5
#5
#5
#5
Bar Spacing:
v = 18.00 in
w = 18.00 in
x = 18.00 in
y = 18.00 in
z = 18.00 in
(z=w)
BAR
NUMBER
MARK
LENGTH
WEIGHT
(LBS.)
TYPE
INC.
D
WINGWALLS
1
SERIES
of 8
2
1
SERIES
of 4
14
3'- 10''
TO
6'- 4''
6'- 4''
3'- 4''
TO
6'- 4''
4'- 0''
WW510
1
SERIES
of 8
6
2
SERIES
of 2
5
2
1
1
SERIES
of 4
6
2
SERIES
of 2
2
3'- 10''
TO
6'- 4''
9'- 8''
4'- 10''
TO
9'- 8''
3'- 10''
12'- 4''
1'- 5''
3'- 4''
TO
6'- 4''
3'- 8''
1'- 10''
TO
3'- 8''
7'- 1''
V501
W501
18
18
4'- 5''
4'- 5''
X501
X502
X503
Y501
WW501
WW502
WW503
WW504
WW505
WW506
WW507
WW508
WW509
43
STR.
14
STR.
21
STR.
60
43
STR.
61
STR.
31
STR.
20
26
2
2
3
8
21
STR.
23
STR.
12
STR.
15
83
83
STR.
STR.
0'-
1'0'- 6''
3'- 8''
0'-
4'0'- 7''
2'- 5''
0'- 7''
0'- 4/1''
2'- 4''
0'- 4/1''
2'- 2 9/4''
9'- 8''
3'- 0/1''
1'-
1'2'- 5''
2'- 10''
3'- 8''
Z501
20
8'- 2''
171
F501
F502
6
8
2
SERIES
of 4
2
SERIES
of 4
1
SERIES
2
1
SERIES
2
9
2
4'- 0''
3'- 2''
17'- 1''
TO
19'- 7''
8'- 11''
TO
11'- 6''
17'- 1''
TO
17'- 9''
8'- 11''
TO
9'- 7''
3'- 7''
11'- 4''
26
27
STR.
STR.
153
86
STR.
37
20
STR.
34
24
1
STR.
F503
F504
F505
F506
F507
F508
3'- 7''
14'- 3 1/4''
TO
17'- 9/4''
1'- 2''
1'- 5/2''
2'- 5/4''
0'14'- 3 1/4''
TO
15'- 1 5/4''
1'- 5/2''
2'- 5/4''
4
13
13
11'- 4''
1'- 5''
2'- 2''
TOTAL
48
20
30
1,234
STR.
5
7
0'-
0'1'- 8''
2'- 0''
FORESLOPE WALL
FS501
FS502
FS503
0'-
0'- 6''
0'- 6''
0'- 8''
0'- 8''
1'- 3''
INC.
3 5/8''
0/1''
3 5/8''
1 0/1''
0/1''
1 0/1''
1 0/1''
8 3/8''
8/1''
6 5/8''
Reference shall be made to the "Concrete Headwalls for Precast Box Culverts" Standard Drawing for headwall dimensions and reinforcing data.
#5
#5
#5
#5
#5
(h2=h1=H)
(L2=L1)
Bar Spacing:
v = 18.00 in
w = 18.00 in
x = 18.00 in
y = 9.00 in
z = 18.00 in
(z=w)
BAR
NUMBER
MARK
LENGTH
WEIGHT
(LBS.)
X501
Y501
26
50
10'- 4''
6'- 0''
281
316
WW501
WW502
26
32
10'- 4''
17'- 8''
281
590
V501
W501
Z501
33
33
33
7'- 8''
7'- 8''
8'- 2''
F501
F502
F503
F504
28
4
9
2
24'24'6'11'-
FS501
FS502
FS503
4
13
13
11'- 4''
3'- 8''
4'- 5''
11''
11''
1''
4''
TOTAL
TYPE
A
WINGWALLS
STR.
1
0'- 6''
48
50
60
STR.
STR.
1
STR.
3'- 8''
FORESLOPE WALL
STR.
5
1'- 6''
7
1'- 6''
3,350
5'- 8''
STR.
STR.
1'- 2''
2'- 6''
0'- 11''
0'- 11''
2'- 3''