NEPLAN
All equipment can be entered graphically and/or table oriented (like in a excel sheet)
A single line diagram can easily be generated through a very user friendly CAD systems.
Extensive editing functions like undo, redo, delete, copy, move and zoom for processing the network
diagram are available. An element can be moved from one node to an other node without deleting the
element.
OLE functionality: Data and graphic can be moved to and from third party software (like MS-Excel, MSWord). Project documentation was never easier.
The equipment data are entered in dialogs, with plausibility checks provided. A coloring tool helps to
show which data is needed for which analysis (e.g. short circuit, transient stability etc.)
Integrated Variant Manager (insert, delete, append, compare variants, compare results, etc.).
ASCII file or SQL database oriented import/export functions for exchanging network data, topology data
and load data are available.
Interfaces to external programs (e.g. measured data acquisition systems) can be implemented.
Import of almost any raster and vector graphic files (e.g. PCX and DXF files).
Graphics can be exported as raster files (e.g. JPG, which can be used in any internet web browser).
Option for combining and separating networks. Any number of independent network areas and zones are
possible. Each element and node can belong to any independent area and zone.
Extensive functions for network statistics and network documentations are available.
A state of the art library manager with extensive libraries for each element type facilitates data entry.
Integrated chart manager allows to analyze and compare all results from all variants.
Languages: program and manual in English, French, Spanish, German and Italian
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Variant Management
Multi-Diagram and
Multi-Layer-Technique
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Auxiliary Graphics
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Symbol-Editor
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Library Manager
Chart Manager
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Engstlatt
Station Kaisterfeld
France
Sierentz
Schlattingen
Gurtweil
Riet
Asphard
Koblenz
Weinfelden
Leibstadt
Muenchwilen
Austria
Toess
Lachmatt
Moerschwil
Wittenwil
Ormalingen
Regensdorf
Birr
Seebach
Rupp
Montlingen
Waldegg
Auwiesen
Aathal
Niederwil
Oftringen
Wollishofen
Faellanden
Mambeli
Thalwil
Lindenholz
Meiningen
Obfelden
Flumenthal
Sursee
Altgass
Pieterlen
Westtirol
Samstagern
Siebnen
Gerlafingen
Littau
Ingenbohl
Mapragg
Kerzers
Pradella
Galmiz
Plattis
Rothenbrunnen
Wattenwil
Mathod
Hauterive
Wimmis
Innertkirchen
Ilanz
Filisur
Goeschenen
Vaux
T.Acqua
Gstaad
Banlieu
La Veyre
Botterens
Ulrichen
Robiei
Peccia
Eysins
Biasca
Fiesch
Veytaux
Ponte
Bitsch
Moerel
Robbia
Bavona
Iragna
Chavalon
Piedilago
Cavergno
Sondrio
Mese
Cornier
Bois Tollot
Foretaille
Avegno
Stalden
Serra
Gorduno
Chandolin
Pressy
Batiaz
Magadino
Vallorcine
Pallanzeno
Musignano
Bulciago
Italy
Valpelline
Avise
Kuehmoos
380 kV
2
3
Sierentz
1
P=11.4
Q=13.3
Ploss=0.0
Qloss=0.0
Load=0.0
P=-49.0
Q=-19.1
Ploss=0.0
Qloss=0.0
Load=0.0
P=242.1
Q=74.1
Ploss=0.0
Qloss=0.0
Load=0.0
P=-660.1
Q=-270.0
Ploss=0.8
Qloss=67.3
Load=71.3
P=242.4
Q=74.1
Ploss=0.0
Qloss=0.0
Load=0.0
P=660.9
Q=337.3
Ploss=0.8
Qloss=67.3
Load=74.2
LindenholzEngstlatt
LeibstadtTiengen
220 kV
A
Gurtweil
A
LAUFENB-TRAFO2
U=243.353
B
LAUFENB-TRAFO3
U=406.600
P=660.9
Q=337.3
Ploss=0.0
Qloss=0.0
Load=0.0
LAUFENB3 R
U=414.144
LAUFENB3 B
U=406.600
P=-660.1
Q=-270.0
Ploss=0.0
Qloss=0.0
Load=0.0
LAUFENB2 R
U=243.353
LAUFENB2 B
U=240.435
Asphard
Bassecourt
Oftringen220kV 380kV
Muenchwilen
Bickigen
Goesgen
P=-148.2
Q=78.2
Ploss=0.0
Qloss=0.0
Load=0.0
ABB
P=172.8
Q=85.3
Ploss=0.0
Qloss=0.0
Load=0.0
P=70.9
Q=-58.4
Ploss=0.0
Qloss=0.0
Load=0.0
P=119.0
Q=-121.4
Ploss=0.0
Qloss=0.0
Load=0.0
220kV 380kV
Beznau
P=37.2
Q=12.8
Ploss=0.0
Qloss=0.0
Load=0.0
ABB AG
www.abb.de/neplan, neplan@de.abb.com
P=-105.3
Q=2.3
Ploss=0.0
Qloss=0.0
Load=0.0
Breite
P=512.1
Q=8.0
Ploss=0.0
Qloss=0.0
Load=0.0
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Source
sqrt(3)
P1
Rt1
Input
Source
Source
- fahrad
Constant
Constant
Sb -> CCS
Source
SG
Ub
Input
Constant
nerator Vd
Limit1
Source
Power
Constant
A ->kA
Inverter
Constant
I1
Vd/dt*C)
Input
Constant
Vd ref
Integrator
Output
LAG
Vd I-Ctrl
u (1/22)
Polar
Vd lag
I1 limit
I1
Source
kA->A
Integrator
Power
Integral
Vs I-Ctrl
Limit1
d=sqrt(U)
Vd limit
Im (I1)
Integrator
A -> kA
Constant
A -> kA
Power
Constant
Source
Power
Vdc init
LAG
Constant
Vs lag
Constant
Output
Constant
Source
I2
Constant
Input
Input
Rad->Deg
delta 1
Constant
Source
Slope
0.5
Power
1/Sb
Constant
Rt2
P2
Source
Input
Source
Vsref
Ub
Source
Source
Input
Vs
Source
eg -> Rad
Constant
Input
Constant
delta3
eg -> Rad
w4
Hz -> pu
Hz -> pu
Input
Constant
w3
delta4
H4 (s)
H3 (s)
Source
Input
Input
Ksh
Source
Constant
1/x
Inverter
SIN
sin DELTA
COS
Constant
delta1
eg -> Rad
Hz -> pu
w2
Input
Constant
Constant
Constant
Input
H1(s)
H2 (s)
Source
Source
eg -> Rad
Hz -> pu
delta2
w1
Input
Input
Inverter
1/x
os DELTA
Source
ted (kV)
K1
Source
Source
Source
K2
Ub
Source
Rt1
Source
Source
(Mvar)
SG
Source
Ub
Source
Xt2
Rt2
Input
Constant
Qline
Integrator
ar -> pu
LAG
Limit1
Polar
Q I-Ctrl
Input
Q smooth
Vpq limiter
Output
Vpq
Rec->Pol
Source
Constant
Delta Q
Constant
(Mvar)
Constant
2
Constant
Integrator
MW->pu
LAG
P I-Ctrl
Source
P smooth
180
Input
Source
Constant
Delta P
f(Mvar)
Input
Constant
Pline
Constant
Rad->Deg
Output
delta Vpq
Source
SG
f (MW)
ZONES
K4
U=219.986
P=6.12
Q=-4.70
Ploss=0.00
Qloss=-5.76
ONE
K3
U=219.794
P=-21.62
Q=1.38
Ploss=0.04
Qloss=-5.58
P=-6.12
Q=-1.06
Ploss=0.00
Qloss=-5.76
TR1
TR2
K6
U=220.095
P=4.50
Q=-0.02
Ploss=0.00
Qloss=-5.76
TWO
P=-18.38
Q=-0.60
Ploss=0.03
Qloss=-5.64
P=-4.50
Q=-5.74
Ploss=0.00
Qloss=-5.76
EL30
K
U=220
EL28
P=21.66
Q=-6.96
Ploss=0.04
Qloss=-5.58
P=18.41
Q=-5.04
Ploss=0.03
Qloss=-5.64
K
U=2
THREE
P=-30.00
Q=4.15
Ploss=0.00
Qloss=-5.40
K12
U=220.622
EL29
P=30.00
Q=-9.55
Ploss=0.00
Qloss=-5.40
K1
U=220
FOUR
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
NEPLAN
EL7
P=-303.0
Q=-109.1
P=0.0
Q=0.0
Load=0.0
EL11
K3
U=218.901
u=99.5
Uang=4.637
K2
U=218.823
u=99.5
Uang=-1.173
K1
U=220.000
u=100.0
Uang=0.000
UPFC-9541
UT=22.182
PhiT=91.531
IQ=0.01
Px=-4.0
QxSer=20.5
Q Sh 0 0
P=-200.0
Q=-29.5
Load=0.0
EL5
P=102.5
Q=75.3
Load=0.0
EL8
P=100.0
Q=50.0
P=0.0
Q=0.0
Load=0.0
P=200.4
Q=33.8
Load=0.0
P=200.0
Q=29.5
Load=0.0
EL4
SER-RLC-158
P=102.2
Q=72.0
Load=0.0
EL3
P=-102.2
Q=-72.0
Load=0.0
EL6
P=-198.2
Q=-32.3
Load=0.0
P=98.2
Q=-17.7
Load=0.0
P=-200.0
Q=-50.0
Load=0.0
P=0.0
Q=0.0
Load=0.0
TCSC-9577
P=-102.0
Q=-70.3
Load=0.0
P=-48.0
Q=30.3
Load=0.0
K6
U=214.265
u=97.4
Uang=-1.732
K7
U=216.155
u=98.3
Uang=-1.145
P=200.0
Q=50.0
Load=0.0
P=0.0
Q=0.0
Load=0.0
P=0.0
Q=0.0
Load=0.0
K4
U=213.251
u=96.9
Uang=-0.156
P=48.0
Q=-29.9
Load=0.0
EL2
K5
U=213.674
u=97.1
Uang=-1.413
EL10
P=150.0
Q=40.0
EL1
P=-98.0
Q=19.9
Load=0.0
EL9
P=50.0
Q=10.0
I=0.023 kA
Load=11.1 %
Ik"(L1)=0.263 kA
Ik"(L1)=0.263 kA
toff=2.00 s
MEDIUM-VOLTAGE
t-lf=42.48 s
toff=0.15 s
I=1.160 kA
Load=123.1 %
Ik"(L1)=13.153 kA
t-lf=56.98 s
I=0.540 kA
Load=135.4 %
Ik"(L1)=0.000 kA
LOW-VOLTAGE
DISTRIBUTION
toff=0.01 s
I=0.097 kA
Load=52.3 %
Ik"(L1)=13.153 kA
MOTOR
Ik"(L1)=14.013 kA
Ik"(L1)=0.926 kA
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Computation procedures: Current Iteration, Newton Raphson, Extended Newton Raphson, Voltage Drop
Voltage and flow control with phase-shifting transformers, controllable three windings transformers.
Node types: slack, PQ, PV, PC, SC, PI, IC. More than one slack node possible.
Predefined and user defined scaling factors for fast load and generation variations
Load balancing
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Results
Self-defined result output: the user can select items, units, font, precision, placement
Overloaded elements or nodes with voltages outside predefined limits are highlighted.
Table output: for the whole network, individually for each area / zone. Listing of power flows
between area/zones, overloaded elements, sorting function, selective output.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
ABB
Line Coupling
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Self-defined result output in regard to units, formats and fault current types.
Results can be inserted either at the beginning and/or end node, or also in the element's center.
In the event of a short-circuit, all overloaded pieces of equipment (current transformers, voltage
transformers, circuit-breakers, etc.) are highlighted.
Results can be saved in a result file (ASCII file) and in an SQL database.
List output: sorted by voltage levels. Short-circuit impedance and all computable fault currents are
output as phase values or as symmetrical components.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Transient Stability
General features
Dynamic models for synchronous machines, asynchronous machines, loads, power electronic devices
(SVC, UPFC, TCSC, STATCOM), HVDC systems, protection devices, control circuits
Various synchronous machine models: classic, transient, subtransient; saturation of d- and q-axis
considered.
Control Circuits
Any control circuit (AVR, GOV, SVC, etc.) may be built freely by basic function blocks.
User friendly editing facilities. Select function blocks from a list, drag into position by mouse,
connect with one another by lines.
Import/export facilities for control circuits between the editor and libraries.
Storage of control circuits, such as, exciter, regulator, PS-stabilizer, V-transducer etc., separately in
the Library.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Transient Stability
Protection Devices
Min-max-relays (overcurrent, undervoltage,
frequency,...): modeled with up to 4 tripping stages. E.g.
various load shedding schemes may be simulated.
Fuses
Pole slip relays, model includes binary input signals from
external sources
Distance protection: pick-up and tripping stages,
impedance diagrams, binary input signals from external
sources.
Disturbances
Generation and storage of various disturbance cases.
Each disturbance case may have more than one event.
Definition of faults (symmetrical and unsymmetrical) on buses, bus elements, branches.
Loss of generator excitation
Different switching operations (feed-forward control in control circuits, cross coupling of protective devices,
in/out of branches, etc.).
Transformer tap modification.
Load shedding scenarios (also in relation to frequency relay).
Disturbances with function generators (step, ramp, sinusoidal function or combination).
Start-up of motors with different start-up devices.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
The NEPLAN Small Signal Stability module provides eigenvalue analysis (modal analysis) for electrical
power systems. It combines exceptional ease of use with the latest techniques and standards in both
electrical power engineering and software design. Like the other modules, Small Signal Stability is a
seamless module within NEPLAN.
Applications
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Automatic construction of the linearized state space notation for the complete system, including
generators, static loads, control circuits, etc.
Advanced synchronous machine modeling: choose for every synchronous machine one of the five models
infinite, classical, transient, subtransient and general. Saturation curves for both, d-axis and q-axis.
Automatic calculation of eigenvalues, eigenvectors, mode shapes, participation factors for eigenvalues
and state variables.
Text results: results are presented in clear form and can be customized by several output options.
Graphical results: results can be visualized by the fully integrated graphical results manager. Charts can
be easily printed and exported to external programs (e.g. Microsoft Word) by clipboard functions. A variety
of chart options is available.
The only requirement is the NEPLAN load flow module. However, the Small Signal Stability and the
Transient Stability (time simulation) module of NEPLAN complement each other ideally.
The Small Signal Stability module is completely integrated in NEPLAN and uses standard dynamic
element data (like the Transient Stability module).
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
As an integral part of NEPLAN software, the Voltage Stability module provides 4 approaches for static voltage
stability analysis of power systems: V-Q curves, P-V curves, V-Q sensitivity analysis and Q-V eigenvalue
analysis (modal analysis). This module allows examination of a wide range of system conditions. It is an ideal
tool to provide much insight into the nature of voltage stability problems.
Applications
Proper distribution of reactive reserves in order to maintain an adequate voltage stability margin
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Automatic calculation of P-V curves, V-Q curves, dV/dQ self-sensitivities, dV/dQ mutual sensitivities,
eigenvalues, eigenvectors, bus participation factors, branch participation factors and generator participation
factors.
Result tables: results are presented in clear form and can be exported by Copy-Paste-methods to external
programs (e.g. MS-Excel).
Graphical results: results can be visualized by the fully integrated graphical results manager.
Export files: results are stored in text files for advanced data export.
Charts can be easily printed and exported to external programs (e.g. MS-Word) by clipboard functions. A
variety of chart options is available.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Harmonic Analysis
ABB
Harmonic Levels
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Harmonic Analysis
Filter Dimensioning
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Overcurrent Protection
All types of protective devices with an overcurrent-time characteristic can be entered: fusegear, circuitbreakers, definite-time overcurrent relays and inverse-time relays, electronic relays.
Extensive libraries with protective devices from a variety of manufacturers are available, and can be extended
at will.
Option for entering user-defined characteristics for simulating motor start-ups or thermal loadability of
conductors, transformers, etc.
Entry options for characteristics: point-by-point or formula in conformity with BS142 or the American ASA
standard.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Overcurrent Protection
Selectivity Diagram
Relays and current transformers are positioned in the network plan graphically.
Transformation ratios of current transformers incorporated in the network plan are allowed for in the
selectivity diagrams.
Selectivity analysis over more than one voltage level, and independently of the network type and size
involved.
Direct connection from short-circuit current and load flow module for
transferring the currents.
Import/export functions.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Network Reduction
This module is designed to reduce the size of a network model by replacing sets of buses and the network
elements (lines, transformers,...) that connect them with a smaller but exact, numerically equivalent network. For
a properly chosen set of buses, this equivalent network will have fewer buses and branches than the original,
yet still provide the correct response to faults or load flow calculations in the unreduced portion.
The network can be reduced for
The reduced network gives the same short circuit or load flow results as the original network. Giving the nodes
to be reduced, the program determines the boundary nodes automatically.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Network Reduction
Input
Output
shunt and series equivalents, which can be saved in the data base
the shunt and series equivalents consists of data for the positive, negative and zero system
dependent on the type of network reduction (load flow or short circuit)
for load flow network reduction boundary injections and boundary generators are calculated
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Control variables: active / reactive power generation, schedule voltages of generators and ULTCtransformers, reference values of HVDC systems and FACTS (UPFC, STATCOM, SVC, TCSC,...)
Variable limits for bus voltages, branch loadings, active and reactive power of generators
Objective function: apply to whole network / to a certain area or zone, minimize / maximize MW losses,
Mvar losses, generation costs, MW import or Mvar import
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Results
Self-defined result output: the user can select items, units, font, precision, placement
Overloaded elements or nodes with voltages outside predefined limits are highlighted.
Table output: for the whole network, individually for each area / zone. Listing of power flows between
area/zones, overloaded elements, sorting function, selective output.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Start-up devices are allowed for, such as stardelta starter, series resistor, transformer.
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Voltage Drop
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Results
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Input Data
User-defined load and generation
profiles (day, week, month and year
factors)
Unlimited number of profile types for
consumers and generators (e.g.
household, industry, ...)
Import of measurement data and
behaviors of power factors
Calculations
Single load flow calculation (load forecast) and
time simulation
User-defined time increment
Combination of time intervals
Load balancing mode: loads are automatically
changed in the way that load flow results fit
best to measured values (behaviors)
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Results
Time behavior and value range charts
Characteristics of network, elements and
nodes (voltages, currents, loadings, power,
MW losses, energy losses,)
Any system quantities may be plotted, or
compared
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Generator models
Asynchronous machine
Synchronous machine
Calculation modules
Load flow
Short circuit
Transient stability
Voltage stability
Harmonic analysis
Typical applications
Protection settings
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
NEPLAN
Reliability Analysis
Probabilistic Reliability Analysis
Determining the frequency, average duration and cost of network component failures, leading to voltage sags
and supply interruptions.
Consideration of
Network operation in normal state and for multiple order network contingencies
Optimum asset allocation and cost-benefit analysis for investments in transmission and distribution
networks
Detailed and objective discussion of network connection concepts for high-demand customers and
power plants
Add-on for NEPLAN-Main a tool to apply Reliability Centered Maintenance (RCM) Strategy, which
leads to substantial reduction of maintenance expenses
ABB
ABB AG
www.abb.de/neplan, neplan@de.abb.com
Kallstadter Strasse 1
D-68309 Mannheim
Stochastic failures
Common-Mode failures
Multiple earth-faults
Calculated results
fd
in #/yr
qd
in min/yr
Td
in hrs
Wd
in MWh/yr
Interruption cost
Cd
in $/yr
Presentation of results
Evaluation functions
Consideration of power/energy-specific