Professional Documents
Culture Documents
SYSTEMS
CATALOGUE
INDEX
2/23
LIFT
CONTROL
CARDS
All system parameters can be adjusted by using 6 buttons and an LCD placed on the card;
Can be used at one speed, two speed, speed controlled and hydraulic lifts without any
extra parts. System can be selected from the menu;
All panels in the group are same and no extra panel is needed;
Serial communication and pre-wired installation with car and landing modules via CAN
BUS;
Floor detection is carried out by counter or encoder system. When an encoder is used,
braking and stopping adjustment can be made by using the buttons on the card or the
buttons on the car panel;
Saving errors on system (last 256 records) with date and time information enables to track
past errors in detail;
Automatic door control according to the stops is achieved by double automatic door
support;
Monitoring the lift status, giving commands, making adjustments and following errors are
possible by a connection to a local computer via RS-232 or to a remote computer using a
modem;
Free programmable inputs and outputs on main controller, car controller and landing
modules for special purposes;
Integrated door bridging safety relays for door pre-opening and re-leveling;
Hand held terminal for operating the controller from any point of CAN BUS;
3/23
LIFT
CONTROL
CARDS
Compatible with two speed, VVVF (geared and gearless) and hydraulic elevators;
Integrated door bridging safety circuit for door pre-opening and re-leveling with open doors;
Integrated automatic door control inputs and outputs for single door;
Emergency lowering with 2x12V batteries for hydraulic lifts. ARL-SARJ charger unit
controls the battery charge;
Easy connection with only 15 cables by using serial car installation boards which reduces
labor and cable costs;
Connection boards, which, are used instead of panel terminals are supplied with flexible
parallel connection cables save extra connection terminals at control panel.
4/23
LIFT
CONTROL
CARDS
All system parameters can be adjusted by using 4 buttons and an LCD placed on the card;
Can be used at one speed, two speed and VVVF lifts without any extra parts. System can
be selected from the menu;
Can be used in group operation up to 2 elevators. All panels in the group are same and no
extra panel is needed;
Floor detection is carried out by counter system. Only 3 magnetic switches for one speed
and 4 for two speed systems including limit switches are used for any number of floors;
An error code with its explanation is displayed on the LCD in case of an abnormal
condition (e.g.. H1:Door cannot be locked);
At normal condition the lift can be monitored by messages on the LCD (Waits for calls,
high speed, low speed, inspection);
Only 15 cables are enough for system to work by using serial car connection (FX_SERI)
which reduces labor and cable costs;
No extra switch is needed at high speed lifts (1.6 m/sec) for early slow down;
5/23
LIFT
CONTROL
CARDS
An economical and practical card for one speed or two speed simple push button lifts up to
8 floors;
Floor detection is carried out by counter system. Only 3 magnetic switches for one speed
and 4 for two speed systems including limit switches are used for any number of floors;
All system parameters (Number of floors, busy delay, door lock wait time, automatic door
yes-no, max. floor to floor travel time, fire park floor, max. time to wait for door close, stop
at floor level on inspection) can be adjusted by user via 3 buttons and 7-segment display
on the card;
7-segment display indicates the car position at normal condition and displays an error code
at abnormal condition;
Fire alarm input, earthquake sensor input, over-load input, car priority switch input,
direction arrow, car lamp, busy , out of service and automatic door outputs are available;
6/23
SPEED
CONTROL
UNITS
Can be used with asynchronous (geared) and synchronous (gearless) lift drives;
High torque motor drive at all speed via space vector modulation;
Elimination of startup problems with generators by the help of controlled motor current;
Over-load, high voltage, low voltage, output short circuit, power lost, line phase control,
over heat, ground fault, over-torque and other necessary protection functions;
7/23
EMERGENCY
RESCUE
CARDS
In case of mains failure it moves the lift which stopped between two floors to floor level,
opens the automatic door and passengers are evacuated in safety;
For lifts with automatic doors, if mains failure occurs at floor level, door is opened and
passengers are evacuated;
Thanks to smart battery charge system which does not tire the batteries and makes them
work for many years;
Because it is integrated into control panel, all the connections necessary for emergency
unit is done in fabric. So the setup time is minimized;
No safety circuit connection is needed. Safety circuit connection is only made to lift
controller;
The starting delay of rescue operation can be adjusted for buildings have diesel
generators;
With LCD program parameters like: max travel time, automatic door type, motor drive
frequency, door opening time, starting delay, language e.tc. can be adjusted easily;
8/23
LIFT
CONTROL
PANELS
Number of Stops:
Up to 8 Stops;
Driving Type:
Lift Speed:
Up to 1 m/sec;
Command Type:
Group Operation:
Not Available;
Parallel Installation;
Car Positioning:
Car Entrance:
Compatibility:
9/23
LIFT
CONTROL
PANELS
Number of Stops:
Up to 16 Stops;
Drive Type:
Lift Speed:
Up to 1.6 m/sec;
Command Type:
Group Operation:
Up to 2 elevators;
Car Installation:
Landing Installation:
Car Positioning:
Car Entrance:
Compatibility:
10/23
LIFT
CONTROL
PANELS
Number of Stops:
Up to 24 Stops;
Drive Type:
Lift Speed:
Up to 2.0 m/sec;
Command Type:
Group Operation:
Up to 4 elevators;
Car Installation:
Landing Installation:
Car Positioning:
Car Entrance:
Door Bridging:
Compatibility:
11/23
LIFT
CONTROL
PANELS
Number of Stops:
Up to 48 Stops;
Drive Type:
Lift Speed:
Up to 2.5 m/sec;
Command Type:
Full collective;
Up or down collective;
Group Operation:
Up to 8 elevators;
Shaft Wiring:
Car Positioning:
By encoder;
By magnetic switches and magnets;
12/23
LIFT
CONTROL
PANELS
Door Bridging:
Test Functions:
Remote Control:
Emergency Alarm:
Compatibility:
13/23
PHOTOCELLS
1 infrared sensor;
2 infrared sensors;
14/23
GRAPHIC LCD
DISPLAYS
Supports up to 32 floors;
Support for CANBus, gray, binary code input, Arkel counter and 7-segment modes;
Programmable logo;
15/23
DOOR
CONTROL
CARDS
KM_20 provides complete hold of the motor with its 4 region motor control and high
resolution encoder input hardware;
In addition to this hardware, it allows swift but comfortable motion of doors with its software
that provides S softening in travel ramps and which has the algorithm that does not require
limit switches;
In order to work with the control panels in complete harmony it can generate Doors are
completely open, Doors are fully closed and Obstruction detected signals. These
signals enable it to work for fire lift doors;
It provides many functions and parameters for manufacturing companies that enable
application flexibility, like motor reduction ratio, motor revolution, motor sheave
circumference and skate open zone;
It provides features for auto-learning of door travel limits (without limit switches);
A nudging function is included with buzzer sound and slow speed closing after a long time
photocell interrupt;
In case of mains failure, it can get the power from 2 pcs 12V batteries and can make floor
controlled door opening. Km_20 controls the battery charge;
All system parameters can be adjusted easily by user via buttons and LCD on the board;
The door position data and the door commands will be monitored during normal operation
and the error message will be monitored during abnormal condition;
16/23
INSPECTION
& ALARM
SETS
Alarm;
Gong;
2 pieces of plugs;
Lightening;
Convenience of controlling from any point on the car by EK-1 hand terminal;
Enables to save from costs by requiring less materials for car buttons, digital, overload, full
load, gong, direction arrows, car lamp, automatic door open & close buttons and inspection
movement buttons
Convenience of controlling from any point on the car by EK-1 hand terminal
17/23
INSPECTION
& ALARM
&
ALARM
SETSSETS
Car installation support for ARL-300 control panels more than 16 stops;
Enables to save from costs by requiring less materials for car buttons, digital, overload, full
load, gong, direction arrows, car lamp, automatic door open & close buttons and inspection
movement buttons;
Convenience of controlling from any point on the car by EK-1 hand terminal;
Inspection switch;
18/23
MAGNETIC
SWITCHES
General Features:
Technical Features:
24 VDC / 100 mA; short circuiting and overload protected signal output;
95 x 18 mm dimensions;
Compatibility:
19/23
OTHER
PRODUCTS
Communicates with ARL-200S and ARL-300 control cards via two cables;
No installation is needed between the car and control panel for car buttons, display,
overload, full load, gong, direction arrows, car lamp, automatic door close & open buttons
and inspection movement buttons. Only security, power and communication connections
are needed and 15 cables are enough for connection between car and control panel.
Can work with all three phase, single phase and electronic-controlled doors;
Has light barrier input, door close input and door limit contact inputs;
By using two potentiometers, the duration of light barrier's braking and door-open waiting
at the floor can be adjusted.
20/23
OTHER
PRODUCTS
21/23
OTHER
PRODUCTS
ChatterBox is a floor announcement system designed for elevators. It notifies the name or
the number of the current floor with a human voice. It also gives overload and out of
service warnings;
Grey code, binary code and counter modes are available as input modes;
ChatterBox board comes loaded with default messages from the factory. But it can also be
customized with the help of a personal computer and the ChatterBox Loader Software.
MRL-Sarj is constant output voltage, current limited lead acid battery charger specially
designed for 12V/7Ah maintenance-free, dry type batteries which charges the batteries
optimally with an appropriate charging technique;
22/23
OTHER
PRODUCTS
Buzzer for sound alert after car reaches the floor level in case main power fails
External lamp output (12V/1W) which can be used to display levelled signal in a different
place
Serial communication unit for ARL-300 lift controller designed for high-rise buildings;
Used in inspection box for car commands, and in control panel for landing calls as an floor
expansion board;
Operation mode selection (for car commands or landing calls) with a Jumper;
Display outputs A,B,C, ... on FX_SERI_32 board can be programmed as 7-segment, Gray
code, inverted Gray code, Binary code and inverted Binary code;
No installation is needed betwen car and control panel for car buttons, indicators, over
load, full load, gong, direction arrows, car light, automatic door open / close buttons,
inspection operation buttons and Gray/Binary code outputs for position indicators.
23/23