You are on page 1of 225

Georgia

Product Catalog

HEIDELBERGCEMENT Group

Introduction
Hanson Pipe & Products, Inc. is descended from Gifford-Hill Pipe Company, which was formed in 1931
for the purpose of manufacturing concrete pipe for sewer and culvert construction and other associated
uses.
The company has grown and prospered, expanding by 1997 to 12 plants located in Texas, Arizona,
Oklahoma and Louisiana. In 1997, Gifford-Hill merged with Concrete Pipe & Products Co., Inc. which
traced its history back to 1923. CP&P operated plants in Virginia, Maryland, Texas and California. The
company again expanded its operations in 1998 through two major acquisitions. North Star Concrete
and Spancrete Midwest Company were purchased from the Condux Corp. These fine companies have
plants in Minnesota, South Dakota and Ohio.
Gifford-Hill American was brought into the Gifford-Hill Concrete Products family through the purchase of
the fifty percent share of GHA formerly owned by Ameron International. In January 1999, Gifford-Hill
became Hanson Pipe & Products, Inc. The name change was intended to strengthen the company's
identity both in the U.S. and abroad, and to unify the pipe and precast operations with the rest of the
Hanson organization.
Hanson Pipe & Products added three new members to its family in 1999. LOC PIPE was established
in Whitby, Ontario, near Toranto, in 1974. The plant produces concrete pipe, precast concrete products
and ribbed PVC pipe for sewers and storm drainage. The plant is ISO 9002 certified and operates as
Hanson Pipe & Precast, Canada.
Hanson increased its structural and architectural precast capabilities with the addition of United
Spancrete Products Corporation. With plants in Irindale and Chula Vista, California, the new precast
operations serve the dynamic Los Angeles and San Diego markets. The former Spancrete will operate
as Hanson Pacific Spancrete.
The addition of Superior Products Company strengthens the Hanson presence in the North Central and
Eastern regions of the U.S. The Superior plant in Macedonia, Ohio near Cleveland, produces concrete
pipe and precast products.
In 2000, Hanson solidified its North Central operations through the acquisition of Cincinnati Concrete
Pipe in Cincinnati, Ohio and Milan Concrete Products in Milan, Indiana.
At the same time, one of the premier pipe and precast operations in the southeastern U.S., JoelsonTaylor Concrete Products, joined the Hanson family. Joelson-Taylor operates eight pipe and precast
plants throughout Florida and a modern precast facility in Summerville, South Carolina near Charleston.
The Joelson-Taylor acquisition gives Hanson a strong position in one of the country's most important
growth areas.
Also in 2000, Hanson expanded into the Pacific Northwest through acquisition of PIPE, Inc. with pipe and
precast operations in Portland and Salem, Oregon and Tacoma, Washington.
In 2001, Hanson's Canadian presence expanded by the acquisition Centennial Concrete Pipe. Centennial
was the major producer of concrete pipe and precast products in Ontario with plants in
Ottawa, Cambridge and Windsor.
(Continued on next page.)

TITLE

Introduction to Concrete Products Catalog

STATE

GA

SECTION PAGE

0 .1

DATE

12-01-10
HEIDELBERGCEMENT Group

Introduction (Continued)
Following Centennial, in 2002, Choctaw, Inc. joined the Hanson Organization. Choctaw was the largest
concrete pipe and precast producer in the deep South with 17 facilities in Arkansas, Louisiana,
Mississippi and Alabama. Hanson then purchased Rinker facilities in Tualatin, Oregon and Everett,
Washington.
In 2004, Hanson acquired CPI, a precast company in Waco, Texas and WPC, a concrete pipe and precast
company in Florida's panhandle. In 2005, Sherman Concrete Pipe Co. with plants in Alabama and
Georgia were added further strengthng Hanson's Southwest Region. In 2006, Hughes supply, Inc. with
precast plants in Athens and Oakwood, Georgia were added. In July 2007, Price Brothers Florida Pipe
operation was acquired.
In August, 2007, Hanson was acquird by the Heidelberg Cement Group making us the largest building
products company in the world.
For over six decades, The Gifford-Hill business philosophy was to offer products at competitive prices
along with courteous customer service. Hanson continues to promote that philosophy through
innovation, hard work and an outstanding staff of production, sales, service, engineering and administration
professionals. With Heidelberg our mission remains simple; "build2gether" to be the best and most
successful at what we do.
Today, in an era where new products challenge concrete pipe's traditional position, Hanson understands
that we must improve our products and services. In that effort, we are exploring new types of concrete,
new types of reinforcement, new joints and new production methods.
Concrete products have formed the backbone of our civilization's infrastructure as long as man has
recorded history. Their features offer unparalleled benefits to the user and make them an essential part
of our society's future. Precast concrete products will provide our bridge to the 21st century and beyond.
We proudly count among our customers State Departments of Transportation, major cities, counties,
public authorities, the Army Corps of Engineers, major airports and numerous private top quality
contractors.
Hanson has proudly participated in some of the largest public works, airport and highway construction
projects in North America, We provide engineered products for engineered applications. Consequently,
our staff includes Registered Professional Engineers in each of our operating areas.
This technical catalog has been prepared to assist you in planning, designing and specifying with
concrete pipe and precast products. We have attempted to present the details in a useful and logical
manner. The details included by no means represent all we can produce or sell; they merely illustrate
our different product lines. We take pride in saying, "Our only limitation is your imagination,"
Thank you for your interest in concrete pipe and precast and for understanding "that often, innovation is
knowing what not to change."
Not all products shown in the sections that follow are manufactured and inventoried at each of our plants.
We encourage you to call our sales office nearest you for availability, or with questions or suggestions.

www.hansonpipeandprecast.com
.

TITLE

STATE

SECTION PAGE

DATE

Introduction to Concrete Products Catalog (Cont.)

GA

0.2

12-01-10
HEIDELBERGCEMENT Group

Georgia - Hanson Pipe & Precast Locations:


Athens, Georgia
625B Hancock Industrial Way
Athens, GA 30605
(706) 227-3355
(706) 227-2276 (FAX)

Rincon, Georgia
500 Ebenezer Rd.
Rincon, GA 31326
(912) 754-9492
(912) 754-3609 (FAX)

Rome, Georgia
223 John Davenport Dr.
Rome, GA 30165
(706) 234-5311
(706) 235-0763 (FAX)

Additional Hanson Pipe & Precast Locations:


Alabama
Dothan
334.792.3621
FAX 334.792.3458

South Carolina
Summerville
843.821.3220
FAX 843.821.8658

Huntsville
256.852.6200
FAX 256.852.9677

Tennessee
3700 Industrial Park Dr.
Lenoir City, TN 37771
(865) 986-1095
(865) 986-3466 (FAX)

Montgomery
334.262.6444
FAX 334.263.6579

501 East Jefferson St.


West Memphis, AR 72301
(870) 735-5514
(800) 238-5299 (WATS)
(870) 735-0331 (FAX)

Pelham
205.664.8494
FAX 205.663.6675
Pelham
(Prestress Division)
205.663.4681
FAX 205.663.4459

2377 Holston Road


Como, MS 38619
(662) 526-0368
(800) 238-5294 (WATS)
(662) 526-9345 (FAX)

Tarrant
205.841.2982
FAX 205.841.0673
Tuscaloosa
205.758.8671
FAX 205.758.5879

hansonpipeandprecast.com
TITLE

Sales & Manufacturing Locations

STATE

SECTION PAGE

DATE

GA

0 .3

12-01-10
HEIDELBERGCEMENT Group

Title

Section.Page

COVER PAGE .................................................................................................................................... 0.0


INTRODUCTION TO CONCRETE PRODUCTS CATALOG .............................................................. 0.1 - 0.2
SALES AND MANUFACTURING LOCATIONS ................................................................................. 0.3

1. Index
Table of Contents ............................................................................................................................... 1.1 - 1.6

2. Reinforced Concrete Pipe


Offset Joint Data for 12" to 96" "B" - Wall and "C" - Wall Pipe ........................................................... 2.1
Guide Specifications for Horizontal Elliptical Culvert and Storm Sewer Pipe ..................................... 2.2
Horizontal Elliptical Reinforced Pipe .................................................................................................. 2.3
Typical One Cut Fabricated Concrete Elbow ..................................................................................... 2.4
Typical Two Cut Fabricated Concrete Elbow ...................................................................................... 2.5
Typical Fabricated Concentric Concrete Tee ...................................................................................... 2.6
Typical Fabricated Eccentric Concrete Tee ........................................................................................ 2.7
Typical Fabricated Eccentric Concrete Wye ....................................................................................... 2.8
Typical Fabricated Concentric Concrete Wye .................................................................................... 2.9
Typical Fabricated Concrete Increaser / Reducer .............................................................................. 2.10
Typical Fabricated Concrete Adapter Round x Elliptical .................................................................... 2.11

3. End Treatments
Information - End Treatments ............................................................................................................. 3.1
Concrete Flared End Sections - Single Offset Joint 15" - 24" ............................................................ 3.2
Concrete Flared End Sections - Single Offset Joint 18" - 42" ............................................................ 3.3
G.D.O.T. 1001-B Straight Endwalls .................................................................................................... 3.4
Endwall for 12" through 48" Pipe (Double Pipe) ................................................................................. 3.5
GDOT Standard Safety End Section .................................................................................................. 3.6
GDOT Safety Inlet Type G1 for 18" Pipe ............................................................................................ 3.7
GDOT Safety Inlet Type G1 for 24" Pipe ............................................................................................ 3.8
15" Headwall with Apron ..................................................................................................................... 3.9
18" Headwall with Apron ..................................................................................................................... 3.10
24" Headwall with Apron ..................................................................................................................... 3.11
30" Headwall with Apron ..................................................................................................................... 3.12
36" Headwall with Apron ..................................................................................................................... 3.13
42" Headwall with Apron ..................................................................................................................... 3.14
48" Headwall with Apron ..................................................................................................................... 3.15
54" Headwall with Apron ..................................................................................................................... 3.16
60" Headwall with Apron ..................................................................................................................... 3.17
66" Headwall with Apron ..................................................................................................................... 3.18
72" Headwall with Apron ..................................................................................................................... 3.19
84" Headwall with Apron ..................................................................................................................... 3.20
12" x 18" Headwall with Apron ........................................................................................................... 3.21
14" x 23" Headwall with Apron ........................................................................................................... 3.22
19" x 30" Headwall with Apron ........................................................................................................... 3.23
TITLE

Table of Contents (Page 1 of 6)

STATE

SECTION PAGE

DATE

GA

1 .1

12-01-10
HEIDELBERGCEMENT Group

Title

Section.Page

4. Manholes
4' Diameter Precast Manhole ............................................................................................................. 4.1
4' Diameter Precast Manhole Concentric Cone ................................................................................. 4.2
4' Diameter Precast Manhole Eccentric Cone .................................................................................... 4.3
5' Diameter Precast Manhole ............................................................................................................. 4.4
5' Diameter Precast Manhole / Reduced ............................................................................................ 4.5
6' Diameter Precast Manhole / Reduced ............................................................................................ 4.6
7' Diameter Precast Manhole / Reduced ............................................................................................ 4.7
8' Diameter Precast Manhole / Reduced ............................................................................................ 4.8
10' Diameter Precast Manhole / Reduced .......................................................................................... 4.9
12' Diameter Precast Manhole / Reduced .......................................................................................... 4.10
Typical Manhole Step Detail ............................................................................................................... 4.11
Manhole Pipe Connection Detail Grout Type - Rigid Connection ....................................................... 4.12
Manhole Pipe Connection Detail Boot Type - Flexible Connection .................................................... 4.13
Manhole Pipe Connection Detail Compression Gasket - Flexible Connection ................................... 4.14
Typical Manhole Section Joint Detail - Rincon ................................................................................... 4.15
Typical Manhole Section Joint Detail - Athens ................................................................................... 4.16
4' Diameter Manhole Product Information Sheet ................................................................................ 4.17
5' Diameter Manhole Product Information Sheet ................................................................................ 4.18
6' Diameter Manhole Product Information Sheet ................................................................................ 4.19
7' Diameter Manhole Product Information Sheet ................................................................................ 4.20
8' Diameter Manhole Product Information Sheet ................................................................................ 4.21
10' Diameter Manhole Product Information Sheet .............................................................................. 4.22
12' Diameter Manhole Product Information Sheet .............................................................................. 4.23

5. Wetwells
4' Diameter Precast Wet Well ............................................................................................................. 5.1
5' Diameter Precast Wet Well ............................................................................................................. 5.2
6' Diameter Precast Wet Well ............................................................................................................. 5.3
7' Diameter Precast Wet Well ............................................................................................................. 5.4
8' Diameter Precast Wet Well ............................................................................................................. 5.5
10' Diameter Precast Wet Well ........................................................................................................... 5.6
12' Diameter Precast Wet Well ........................................................................................................... 5.7
Rectangular or Square Wetwells, Various Sizes ................................................................................ 5.8

6. Precast Drainage Structures


Knock-out Boxes ................................................................................................................................ 6.1
Large Rectangular Storm Structures .................................................................................................. 6.2
Storm Manhole, 48" - 144" Diameter with Topslab ............................................................................. 6.3
Storm Manhole, Reducer Type with Topslab ...................................................................................... 6.4
Storm Manhole, Reducer Type with Cone .......................................................................................... 6.5
48" Dia. GDOT 1011A Manhole .......................................................................................................... 6.6
3' x 3' GDOT 1019A Drop Inlet ........................................................................................................... 6.7

TITLE

Table of Contents (Page 2 of 6)

STATE

SECTION PAGE

DATE

GA

1 .2

12-01-10
HEIDELBERGCEMENT Group

6. Precast Drainage Structures (cont.)


Title

Section.Page

48" Diameter GDOT 1019A Drop Inlet ............................................................................................... 6.8


2' x 2' GDOT 1019A Type E Curb Inlet ............................................................................................... 6.9
48" Dia. GDOT 1019A Type E Curb Inlet ........................................................................................... 6.10
48" Dia. GDOT 1033D / 1034D Curb Inlet .......................................................................................... 6.11
3' x 3' GDOT 1033D / 1034D Inlet ...................................................................................................... 6.12
GDOT 1033D - Left Top Slab ............................................................................................................ 6.13
GDOT 1033D - Right Top Slab .......................................................................................................... 6.14
GDOT 1034D - Top Slab ................................................................................................................... 6.15
48" Diameter GDOT 9031-S Inlet ....................................................................................................... 6.16
2' x 2' GDOT 9031-S Drop Inlet .......................................................................................................... 6.17
GDOT Type 9031-S Single Weir Top Slab ......................................................................................... 6.18
GDOT Type 9031-S Double Weir Top Slab ........................................................................................ 6.19
GDOT Ditch Drop Inlet ....................................................................................................................... 6.20
GDOT Median Drop Inlet for 15" Pipe ................................................................................................ 6.21
48" Dia. GDOT 9031-U Junction Box ................................................................................................. 6.22
3' x 4' City of Savannah Type "A" Curb Inlet ....................................................................................... 6.23
Savannah Type "A" Top Slab for Curb Inlet ........................................................................................ 6.24
3' x 4' Savannah Type "B" Left Curb Inlet ........................................................................................... 6.25
Savannah Type "B" Left Top Slab for Curb Inlet ................................................................................. 6.26
3' x 4' City of Savannah Type "B" Right Curb Inlet ............................................................................. 6.27
City of Savannah Type "B" Right Top Slab for Curb Inlet ................................................................... 6.28
3' x 4' City of Savannah Type "C" Curb Inlet ...................................................................................... 6.29
Savannah Type "C" Top Slab for Curb Inlet ........................................................................................ 6.30
3' x 4' City of Savannah Type "B" Left Curb Inlet w/Throat ................................................................. 6.31
City of Savannah Precast Type "B" - Left Throat ................................................................................ 6.32
City of Savannah Precast Type "B" - Left or Right Throat Details ...................................................... 6.33
3' x 4' City of Savannah Type "B" Right Curb Inlet w/Throat .............................................................. 6.34
City of Savannah Precast Type "B" - Right Throat ............................................................................. 6.35
City of Savannah Type "C" Curb Inlet w/ Throat ................................................................................. 6.36
City of Savannah Precast Type "C" Throat ......................................................................................... 6.37
City of Savannah Precast Type "C" Throat - Steel Reinforcement Detail ........................................... 6.38
3' x 3' City of Savannah Roof Inlet ..................................................................................................... 6.39
City of Savannah Standard D6 Roof Inlet Top Slab ........................................................................... 6.40

7. Utility Vaults
Valve Vault with Bottom Slab .............................................................................................................. 7.1
Valve Vault with Open Bottom ............................................................................................................ 7.2
2' - 0" x 2' - 0" x 1' to 4' Pull Box w / 6" Walls (PB2424) ...................................................................... 7.3
2' - 0" x 3' - 0" x 1' to 4' Pull Box w / 4" Walls (PB2436) ...................................................................... 7.4
3' - 0" x 3' - 0" x 1' to 4' Pull Box w / 6" Walls (PB3636) ...................................................................... 7.5
3' - 0" x 3' - 0" x 4' - 0" Hand Hole w / 6" Walls (HH3636) ................................................................... 7.6
4' - 0" x 4' - 0" x 1' to 6' Pull Box w / 6" Walls (PB4848) ...................................................................... 7.7
4' - 0" x 4' - 0" x 6' - 0" Hand Hole w / 6" Walls (HH4848) ................................................................... 7.8
(Utility Vaults con't. on next page.)
TITLE

Table of Contents (Page 3 of 6)

STATE

SECTION PAGE

DATE

GA

1 .3

12-01-10
HEIDELBERGCEMENT Group

7. Utility Vaults (Con't.)


4' - 0" x 6' - 0" x 6' to 10' Manhole w / 6" Walls (MH4896) ................................................................... 7.9
5' - 0" x 5' - 0" x 5' - 0" Hand Hole w / 6" Walls (HH6060) ................................................................... 7.10
5' - 0" x 10' - 0" x 6' to 8' Manhole w / 6" Walls (MH60126) ................................................................. 7.11
6' - 0" x 6' - 0" x 6' to 10' Manhole w / 6" Walls (MH7272) ................................................................... 7.12
6' - 0" x 8' - 0" x 6' to 10' Manhole w / 6" Walls (MH72108) ................................................................. 7.13
6' - 0" x 12' - 0" x 7' to 12' Manhole w / 6" Walls (MH72144) ............................................................... 7.14
8' - 0" x 8' - 0" x 5' to 8' Octogonal Manhole w / 6" Walls (MH96960) ................................................. 7.15
10' - 0" x 10' - 0" x 5' to 8' Octogonal Manhole w / 6" Walls (MH1201200) ......................................... 7.16
Bell South Standard 4620 Handhole (HH4260) ................................................................................. 7.17
4' - 0" x 6' - 0" x 4' - 0" Hand Hole w / 6" Walls (HH4896) ................................................................... 7.18
6' - 0" x 6' - 0" x 6' - 0" Hand Hole w / 6" Walls (HH7272) ................................................................... 7.19
4' - 0" x 4' - 0" x 6' to 12' Hand Hole w / 6" Walls (HH4848) ................................................................ 7.20
4' - 0" x 6' - 0" x 6' to 12' Manhole w / 6" Walls (MH4872) ................................................................... 7.21
4' - 0" x 6' - 6" x 6' to 8' Manhole w / 5" Walls (MH4878) ..................................................................... 7.22
6' - 0" x 8' - 0" x 5' to 12' Manhole w / 6" Walls (MH7296) ................................................................... 7.23
Type A-Center Duct 6' x 12' x 7' Manhole (MH72144A) ..................................................................... 7.24
Type A-Lateral 6' x 12' x 7' Manhole (MH72144A) ............................................................................. 7.25
Type T-Center Duct 6' x 12' x 7' Manhole (MH72144T) ...................................................................... 7.26
Type T-Lateral 6' x 12' x 7' Manhole (MH72144T) .............................................................................. 7.27
Type J4-Center Duct 6' x 12' x 7' Manhole (MH72144J4) .................................................................. 7.28
Type J4-Lateral 6' x 12' x 7' Manhole (MH72144J4) .......................................................................... 7.29
6' x 10' x 6' to 10' Manhole w / 6" Walls (MH72180) ............................................................................ 7.30
8' - 0" x 8' - 0" x 6' to 10' Manhole w / 6" Walls (MH9696) ................................................................... 7.31
8' - 0" x 12' - 0" x 4' - 6" to 7' Manhole w / 6" Walls (MH9696) ............................................................ 7.32
10' - 0" x 16' - 0" x 8' - 0" Manhole w / 6" Walls (MH120192) .............................................................. 7.33
10' - 0" x 20' - 0" x 8' - 0" Manhole w / 6" Walls (MH120240) .............................................................. 7.34
3' - 0" x 4' - 0" x 1' to 4' Pull Box w / 4" Walls (PB3648) ...................................................................... 7.35
3' - 0" x 5' - 0" x 1' to 5' Pull Box w / 6" Walls (PB3660) ...................................................................... 7.36
Bell South Standard 4620 Pull Box (PB4260) .................................................................................... 7.37
4' - 0" x 6' - 0" x 1' to 5' Pull Box w / 6" Walls (PB4872) ...................................................................... 7.38
4' - 0" x 6' - 6" x 1' to 5' Pull Box w / 5" Walls (PB4878) ...................................................................... 7.39
4' - 0" x 6' - 0" x 4 - 0" Pull Box w / 6" Walls (PB4896) ........................................................................ 7.40
2' - 0" x 2' - 0" x 1' to 4' Utility Vault w / 4" Walls (UV2424) ................................................................. 7.41
3' - 0" x 3' - 0" x 1' to 4' Utility Vault w / 4" Walls (UV3636) ................................................................. 7.42
4' - 0" x 4' - 0" x 1' to 6' Utility Vault w / 4" Walls (UV4848) ................................................................. 7.43
4' - 0" x 6' - 6" x 1' to 6' Utility Vault w / 5" Walls (UV4878) ................................................................. 7.44
Equipment Pad, Type 1 ...................................................................................................................... 7.45
Equipment Pad, Type 2 ...................................................................................................................... 7.46
Equipment Pad, Type 3 ...................................................................................................................... 7.47
3' - 0" x 4" - 8" x 40" Mounting Pit w / 6" Walls .................................................................................... 7.48
3' - 0" x 4" - 0" x 40" Mounting Pit w / 6" Walls .................................................................................... 7.49
5' - 0" x 5" - 0" x 40" Mounting Pit w / 6" Walls .................................................................................... 7.50
6' - 0" x 6" - 0" x 40" Mounting Pit w / 6" Walls .................................................................................... 7.51

TITLE

STATE

SECTION PAGE

DATE

Table of Contents (Page 4 of 6)

GA

1.4

12-01-10
HEIDELBERGCEMENT Group

8. Precast Box Culverts & Crown-Span


Information - Precast Box Culvets & Crown-Span ............................................................................. 8.1- 8.2
Dimensions, Weights & Joint Details - Box Culvert ............................................................................ 8.3
Full Flow Hydraulic Data - Box Culverts ............................................................................................. 8.4
Dimensions, Weights & Joint Details - Crown-Span .......................................................................... 8.5
Crown-Span Footing and Floor - Single Line ..................................................................................... 8.6
Crown-Span Footing and Floor - Multiple Lines ................................................................................. 8.7
Precast Box Reinforcement Section Details ....................................................................................... 8.8
Precast Box Design Technical Details and Notes .............................................................................. 8.9
Crown-Span Reinforcement Section Details ...................................................................................... 8.10
Crown-Span Design Technical Details and Notes .............................................................................. 8.11
AASHTO / ASTM Precast Section Design Parameters ...................................................................... 8.12
Precast Box and Crown-Span Wing Wall (BWW) .............................................................................. 8.13
End Wall (ES) and Wing Wall (BWW) Connection Details ................................................................. 8.14
End Wall (ES) and Wing Wall (BWW) Connection Details (Page 2) .................................................. 8.15
Precast Layout with Cast-in-Place Headwalls .................................................................................... 8.16
Pecast Openings in Precast Rectangular Sections ............................................................................ 8.17
Precast Box Culvert - Single Cell ....................................................................................................... 8.18
Precast Box Culvert - End Treatment Detail ....................................................................................... 8.19
Precast Box Culvert - Skewed Ends .................................................................................................. 8.20

9. Premier Modular Railroad Crossings


Premier Notes .................................................................................................................................... 9.1- 9.2
Premier Modular Railroad Crossing - Typical Section ........................................................................ 9.3
Premier Modular Railroad Crossing - Curved Alingments (Diverged) ................................................ 9.4
Premier Modular Railroad Crossing - Curved Alingments (Tapered) ................................................. 9.5
Premier Modular Railroad Crossing - Curve Data Chart .................................................................... 9.6
Premier Modular Railroad Crossing - Boot & Optional Fillers ............................................................ 9.7
Premier Modular Railroad Crossing - 4'-0" Premier Unit (Isometric View) ......................................... 9.8
Premier Modular Railroad Crossing - 4'-0" Premier Unit (Plan View) ................................................. 9.9
Premier Modular Railroad Crossing - 8'-0" Premier Unit (Isometric View) ......................................... 9.10
Premier Modular Railroad Crossing - 8'-0" Premier Unit (Plan View) ................................................. 9.11
Premier Modular Railroad Crossing - 4'-0" Premier Plus Unit (Isometric View) ................................. 9.12
Premier Modular Railroad Crossing - 4'-0" Premier Plus Unit (Plan View) ......................................... 9.13
Premier Modular Railroad Crossing - 8'-0" Premier Plus Unit (Isometric View) ................................. 9.14
Premier Modular Railroad Crossing - 8'-0" Premier Plus Unit (Plan View) ......................................... 9.15

10. Miscellaneous
American Concrete Pipe Association - Design Data - Table of Contents ........................................... 10.1- 10.2

TITLE

Table of Contents (Page 5 of 6)

STATE

SECTION PAGE

DATE

GA

1.5

12-01-10
HEIDELBERGCEMENT Group

11. Design Aids


Title

Section.Page

Glossary - Terms used in this Catalog ................................................................................................ 11.1


Design Red Lights (Check List) .......................................................................................................... 11.2
Standard Hole Diameters ................................................................................................................... 11.3
Pipe Half Angle Table Example #1 ..................................................................................................... 11.4
Pipe Half Angle Table Example #2 ..................................................................................................... 11.5
Pipe Half Angle Diagram .................................................................................................................... 11.6
Pipe Half Angle Table ......................................................................................................................... 11.7
Maximum Pipe Angle Tables: Instructions / Examples ....................................................................... 11.8
Pipe Angle Diagram Flat Wall Structures ........................................................................................... 11.9
Maximum Pipe Angle Flat Wall Structures - Table I ............................................................................ 11.10
Maximum Pipe Angle Flat Wall Structures - Table II ........................................................................... 11.11
Rebar Chart ..................................................................................................................................... 11.12
Welded Wire Mesh Chart ................................................................................................................... 11.13
Steel Equivalency Chart ..................................................................................................................... 11.14
Casting Specifications ........................................................................................................................ 11.15

12. Engineering
Title

Section.Page

ASTM C-76 & ASTM C655 Comparison ........................................................................................... 12.1


Reference Specifications .................................................................................................................... 12.2
Tables: Full Flow Constants ............................................................................................................... 12.3 - 12.7

TITLE

Table of Contents (Page 6 of 6)

STATE

SECTION PAGE

DATE

GA

1 .6

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

Tongue and Groove

Bell and Spigot


Optional: Mortar, preformed
flexible sealant, rubber gasket,
or other suitable sealant.

42" - 96"

12" - 36"

Section View

B-Wall
Size
(In.)

Wall
Thickness
(in.)

Weight
(lbs./ft.)

12
15
18

2
2 1/4
2 1/2

108
140
192

24
30
36

3
3 1/2
4

293
423
550

42
48
54

4 1/2
5

686
867

C-Wall
Wall
Thickness
(In.)

Weight
(lbs./ft.)

6 1/4

1,208

60
66
72

6 3/4
7 1/4
7 3/4

1,473
1,735
2,015

84
96

8 3/4
9 3/4

2,660
3,355

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

Offset Joint Data for 12" to 96"


"B" - Wall and "C" - Wall Pipe

STATE

GA

SECTION PAGE

2.1

DATE

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

Guide Specifications for Horizontal Elliptical


Culvert and Storm Sewer Pipe

Reinforced concrete Horizontal Elliptical culvert and storm sewer pipe shall be in accordance with
ASTM C 507. Pipe shall be Class II, III, IV, or special design as shown. Joints shall be tongue
(spigot) and groove (bell) which are sealed with profile gaskets per ASTM C443 or mortar or
preformed flexible sealants per ASTM C990 and AASHTO M 198, or other suitable sealant. Except
for specials and closure pieces, pipe shall not be less than 8 feet in length.
Pipe shall be installed in accordance with ASTM C 1479 and ASCE 15, Type 3 installation unless
otherwise shown.

TITLE

Guide Specifications for Horizontal


Elliptical Culvert and Storm Sewer Pipe

STATE

SECTION PAGE

DATE

GA

2.2

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe


Wall

96"

PIPE DIMENSIONS
(Side View)
Wall

Rise

Span

JOINT DETAIL

PIPE & JOINT DATA


Horizontal
Rise x Span
Size, in.

Vertical
Rise x Span
Size, in.

ASTM C-507

Equiv.
Round
in.

Area
sq. ft.

Wall
Thickness
in.

Weight
lbs./ft.

12 x 18

15

1.2

3 1/2

233

14 x 23

18

1.8

3 5/8

280

19 x 30

24

3.3

3 5/8

300

24 x 38

30

5.1

3 3/4

430

29 x 45

45 x 29

36

7.4

4 1/2

625

34 x 53

53 x 34

42

10.2

815

38 x 60

60 x 38

48

12.9

5 1/2

1,000

-No ScaleAll dimensions subject to allowable


specification tolerances.

Note:
A. All dimensions are nominal and within the permissible variations of ASTM.
TITLE

Horizontal Elliptical
Reinforced Concrete Pipe

STATE

SECTION PAGE

DATE

GA

2.3

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

e)
) Pip
pe
Pi HE
ar &
e)
ul s
) Pip
irc xe
o
C
pe
. ( (B
Pi HE
.D n
ar &
O pa
ul s
S
irc oxe
de
C
si
. ( (B
I.D pan
S

ut
O
de

si

In
.

.L

L
ll

0.06' Creep

Spigot L.L.

Be

Plan View

Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C 14, C 76, C 361, C 507, C 1433, C 1577 & AASHTO.
TITLE

Typical One Cut Fabricated Concrete Elbow

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2.4

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

e)
)
ip
pe
Pi al P
ar ic
ul ipt
e)
e)
irc (Ell
ip l Pip
C
P
n
.(
ca
ar
.D Spa
ul pti
O
irc Elli
de
C
(
si
.( n
ut
O
I.D Spa
de
si
In

L.

.
lL

Be

ot
ig
Sp
L.
L.

0.

06

'C

re

ep

Plan View
Note:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Details apply to circular T&G, O-Ring, Elliptical Pipe

ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.


TITLE

Typical Two Cut Fabricated Concrete Elbow

STATE

SECTION PAGE

DATE

GA

2.5

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

Joint
Gap

Spigot L.L.

12" Preferred Min.

"A"

(12" to End of Bell


For T&G)

"A"
Outlet L.L.

Bell L.L.

As Req'd.

C Outlet

Plan View

I.D.

Wa

ll

Section A-A
Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.
TITLE

Typical Fabricated Concentric Concrete Tee

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2 .6

12-01-10
HEIDELBERGCEMENT Group

12" Preferred Min.


( 12" to End of
Bell for T&G)

Spigot Laid Length

Joint Gap

Reinforced Concrete Pipe

"A"

"A"
Outlet
Laid Length

As Req'd.

Bell Laid Length

C Outlet

As Req'd.

Plan View

I.D.

Wa

ll

Section A-A
Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.
TITLE

Typical Fabricated Eccentric Concrete Tee

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2 .7

12-01-10
HEIDELBERGCEMENT Group

Standard Joint Length

Spigot L.L.

Reinforced Concrete Pipe

Br

an

ch

L.L

Bell L.L.

CO

utl

et

Offset

Plan View

.
I.D

Wa

ll

Approximate Section
Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.
TITLE

Typical Fabricated Eccentric Wye

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2.8

12-01-10
HEIDELBERGCEMENT Group

Standard Joint Length

L.L.

Spigot

Reinforced Concrete Pipe

Br

Bell L.L.

an

ch

L.

L.

12

"P

r
M
in efe
im rr
um ed

Plan View

Br

an

ch

I.D.

Wa

ll

End View
Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.
TITLE

Typical Fabricated Concentric Wye

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2.9

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

C Outlet

C Intlet

Plan View

Size B

Size A

Length

End View
Eccentric Shown
Concentric Available

Elevation

Note:
(1.) Details apply to circular T&G, O-Ring, & R&S, Elliptical Pipe, and Precast Box

Sections; ASTM C14, C76, C361, C507, C1433, C1577 & AASHTO.
TITLE

Typical Fabricated Concrete Increaser / Reducer

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

2.10

12-01-10
HEIDELBERGCEMENT Group

Reinforced Concrete Pipe

Plan View

Length

ASTM C76

ASTM C507

Elevation

End View

Note:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Concentric adapter shown. Matching inverts and matching

crowns are also available.


TITLE

Typical Fabricated Concrete Adapter


Round x Elliptical

STATE

SECTION PAGE

DATE

GA

2.11

12-01-10
HEIDELBERGCEMENT Group

End Treatments
Use
Precast concrete end treatments are designed to anchor the pipe or box sections
into the surrounding embankment, reduce hydraulic entrance and exit losses,
and to control erosion.
Sizes
Precast end treatments are normally available to accommodate all sizes and shapes
of pipe. Please refer to the details that follow for specific sizes and dimensions.
Application
Precast end treatments are used for the following:
culverts beneath highway or railroad embankments
storm drain or sewer outfalls
anywhere a pipe must conform to the slope of the surrounding terrain.
Joints
Precast endwalls normally have no joints.
End sections are produced with the same joints as the pipe they are connected to.
Applicable Specifications
Precast end treatments can be produced to Department of Transportation specifications .

TITLE

Information - End Treatments

STATE

SECTION PAGE

DATE

GA

3.1

12-01-10
HEIDELBERGCEMENT Group

Wall

End Sections / Endwalls

Wall

R-1

Plan View
L
B

Slope

I.D.
A

Dia. + 1"

Section A-A

Front View

Standard Dimensions
Pipe
Dia.
(In.)

Slope

Wall
(In.)

R-1

Wt. per
Section
(lbs.)

15
18
24

2.2:1
2.2:1
2.4:1

2 1/4
2 1/2
3

6"
9"
9 1/2"

2' - 3"
2' - 3"
3' - 8"

3' - 10"
3' - 10"
2' - 5"

6' - 1"
6' - 1"
6' - 1"

2' - 6"
3' - 0"
4' - 0"

11"
1' - 0"
1' - 2"

740
990
1,520

Note:
(1.) Dimensions may vary due to form variations.
(2.) Bell or spigot joints are available.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Concrete Flared End Sections


Single Offset Joint

GA

3.2

12-01-10
HEIDELBERGCEMENT Group

End Sections / Endwalls

Plan View

6' - 0" - 8' - 0"

I.D.

Elevation

End View

Note:
(1.) Dimensions may vary due to form variations.
(2.) Bell or spigot joints are available.
(3.) Sections are available for the following pipe diameters
18", 24", 30", 36" and 42".
TITLE

Concrete Flared End Section


Single Offset Joint

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

3.3

12-01-10
HEIDELBERGCEMENT Group

4"

4"

Precast Drainage Structures

Plan View

G = 4D

10"

4"

4"

Front View

Side View
Dimensions
Pipe
Size

15"
18"
24"
30"
36"
42"
48"
54"

2' - 6"
2' - 9"
3' - 3"
3' - 9"
4' - 3"
4' - 9"
5' - 3"
5' - 9"

1' - 2" 1' - 10"


1' - 3" 1' - 11"
1' - 4"
2' - 0"
1' - 6"
2' - 2"
1' - 8"
2' - 4"
1' - 10" 2' - 6"
2' - 1"
2' - 9"
2' - 6"
3' - 2"

1' - 2"
1' - 3"
1' - 4"
1' - 6"
1' - 8"
2' - 0"
2' - 0"
2' - 3"

5' - 0"
6' - 0"
8' - 0"
10' - 0"
12' - 0"
14' - 0"
16' - 0"
18' - 0"

Product Specifications
This Endwall is similar to GDOT 1001-B.

Materials
CONCRETE: 4,000 PSI, Type II cement.
WALL REINFORCING: #4 @ 12" O.C. Min.*
BOTTOM SLAB REINFORCING: #4 @ 12" O.C. Min.*
NOTE:
* Grade 40, or equivalent welded wire mesh.

TITLE

G.D.O.T. 1001-B Straight Endwalls

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

3.4

12-01-10
HEIDELBERGCEMENT Group

End Sections / Endwalls


9"

"H"

"

"A"

"A"

"M

"D"

"D"

"L"

See Note #5 (typ.)

"B"

Isometric View
Basic Dimensions

I.D.
Pipe
(In.)

"D"
(RCP)
(In.)

"D"
(DIP)
(In.)

"D"
(CMP)
(In.)

"H"

"B"

"L"

"M"

"A"
(In.)

12
15
18

20
26
26

16
N/A
22

18
20
24

4'-0"
4'-0"
4'-0"

2'-0"
2'-0"
2'-0"

8'-2"
8'-2"
8'-7"

2'-2"
2'-2"
2'-7"

8
8
8

24
30
36

32
42
48

28
36
42

30
36
42

4'-0"
5'-0"
5'-4"

2'-0"
2'-6"
2'-8"

11'-5"
13'-3"
16'-0"

3'-5"
4'-3"
5'-0"

8
8
10

42
48

54
62

N/A
N/A

48
54

6'-0"
6'-8"

3'-0"
3'-4"

18'-5"
21'-0"

5'-10"
6'-8"

10
10

Materials & Features:


(1.) Structural design specifications conform to latest ASTM C 913 specifications for "Precast Concrete
Water and Wastewater Structures".
(2.) Concrete compressive strength 4,000 psi minimum.
(3.) Steel reinforcing design to conform to the requirements of ASTM C 890 Specifications for "structural design
loading for water and wastewater structures" and shall utilize grade 60 re-bars conforming to the requirements of
ASTM A 615 or WWF conforming to the requirements of ASTM A 185 or both.
(4.) Additional reinforcing at openings.
(5.) Pipe penetration to be as per job requirements. Pipe to be grouted by contractor as per GDOT requirements.

TITLE

Endwall for 12" Through 48" Pipe (Double Pipe)

STATE

SECTION PAGE

DATE

GA

3.5

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Joint Design to fit Inlet


or Outlet End of Pipe
as Specified

6"
Min.

Plan View
(Bar Grate not Shown)

2" CL
Typ.

Min. 2 Lines of
Circum. Reinf.

2" CL
Typ.

6"
Max.

6 : 1 Slope
#4 Rebar, Each Side

Section B-B

Alternate 3
Pipe
Diameter

T
(Min)

15"

3"

15"

21"

4' - 6"

18"

3"

18"

24"

6' - 0"

24"

3"

24"

30"

9' - 0"

30"

4"

30"

38"

12' - 6"

NOTE:
F'c = 4,000 psi.
Bells or Spigots Available.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT Standard Safety End Section

STATE

SECTION PAGE

DATE

GA

3.6

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6' - 0 1/8"

6"

4' - 10"

8"

3"

3' - 10"

8"

1' - 0"

1' - 0"

6' - 10 1/8"

8"

3' - 10"
2"

7' - 0"

1' - 6"

8"

3' - 5 3/4"

9" 1' - 8 1/2"

8"

8"

3' - 5 3/4"

1/

1' - 5"
6 1/4"

12"

4 1/4"

4' - 10"

Specifications
(1.) 4,000 p.s.i. CONCRETE.
(2.) STEEL: Base Slab - #4 @ 12" 0.C.E.W.
Walls - #4 @ 12" 0.C.E.W. with additional
bars around opening.
(3.) WEIGHT: 6,180 Lbs.
NOTE:

(a.) GRANITE ROCK REQUIRED.

-No ScaleAll dimensions subject to allowable


specification tolerances.

(b.) REBAR GRATE AVAILABLE.


TITLE

GDOT Safety Inlet Type G1 for 18" Pipe

STATE

GA

DATE

3.7

12-01-10

SECTION PAGE

HEIDELBERGCEMENT Group

Precast Drainage Structures

8' - 5 3/16"

6"

5' - 4"

8"

3"

4' - 4"

8"

1' - 0"

1' - 0"

9' - 3 3/16"

8"

4' - 4"

9' - 6"

2' - 0"

8"

4' - 1"

9" 2' - 3 3/4"

8"

8"

4' - 1"

3/ "
4

1' - 11"
6 1/4"

12"

4 1/4"

5' - 4"

Specifications
(1.) 4,000 p.s.i. CONCRETE.
(2.) STEEL: Base Slab - #4 @ 12" 0.C.E.W.
Walls - #4 @ 12" 0.C.E.W. with additional
bars around opening.
(3.) WEIGHT: 8,380 Lbs.
NOTE:

(a.) GRANITE ROCK REQUIRED.

-No ScaleAll dimensions subject to allowable


specification tolerances.

(b.) REBAR GRATE AVAILABLE.


TITLE

GDOT Safety Inlet Type G1 for 24" Pipe

STATE

SECTION PAGE

DATE

GA

3 .8

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'5"

1' - 7"

6"

4' - 2"

2' - 9"

12"

Specifications

3' - 9"
1' - 3"

20" Hole
(Sink 3")

6" 6"

2' - 9"

12"

6' - 3"

(1.) 4,000 p.s.i. concrete.


Hole Normally Flush

(2.) #4 @ 12" C/C


(3.) All walls 6" thick.

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 15" CMP.
TITLE

15" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3 .9

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'5"

1' - 7"

6"

4' - 2"

2' - 9"

12"

Specifications

3' - 9"
2' - 1"

26" Hole
(Sink 4")

6" 6"

2' - 9"

12"

6' - 3"

(1.) 4,000 p.s.i. concrete.


Hole Normally Flush

(2.) #4 @ 12" C/C


(3.) All walls 6" thick.

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 18" & 24" CMP.
TITLE

18" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.10

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'-

11

"

2' - 0"

4' - 9"

3' - 5"

12"

Specifications

2' - 6"

4' - 4"

ole
" H ")
34
3
nk
(Si

6" 6"

3' - 4"

12"

7' - 2"

(1.) 4,000 p.s.i. concrete.


(2.) #4 @ 12" C/C

Hole Normally Flush

(3.) All walls 6" thick.

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 30" CMP.
TITLE

24" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.11

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'

-1

1"

2' - 0"

4' - 9"

3' - 5"

12"

6" 6"

(1.) 4,000 p.s.i. concrete.


(2.) #4 @ 12" C/C

4' - 4"

ole
" H ")
9
4
3
ink
(S

2' - 6"

Specifications

3' - 4"

12"

7' -2"

(3.) All walls 6" thick.


Hole Normally Flush

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 36" CMP.
TITLE

30" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.12

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3'

-7

"

2' - 6"

5' - 10"

4' - 4"

12"

6" 6"

(1.) 4,000 p.s.i. concrete.


(2.) #4 @ 12" C/C

5' - 4"

ole
" H ")
8
4
4
ink
(S

3' - 3"

Specifications

4' - 4"

12"

9' - 2"

(3.) All walls 6" thick.


Hole Normally Flush

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 42" & 48" CMP.
TITLE

36" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.13

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3' - 0"

6' - 9"

"

4'

-2

5' - 4"

6' - 4"

54" Hole
(Sink 9")

12"

6" 6"

4' - 0"

5' - 4"

18"

11' - 2"

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
(3.) All walls 6" thick.
NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 54" & 60" CMP.
TITLE

42" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.14

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

"
-2
4'

3' - 0"

6"

6' - 9"

5' - 4"

6' - 4"

12"

11' - 2"

6"
6"

1' - 0"

4' - 0"

5' - 4"

62" Hole

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
(3.) All walls 6" thick.
NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.

TITLE

48" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.15

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3' - 6 1/2"

7' - 6"

4'

5"

6' - 3"

7' - 0"

4' - 6"

72" Hole
(Sink 9")

6" 6"

12"

6' - 0"

12"

11' - 7"

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
(3.) All walls 6" thick.
NOTE:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 66" & 72" CMP.
TITLE

54" Headwall with Apron

STATE

GA

SECTION PAGE

3.16

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3' - 6 1/2"

7' - 6"

4'

5"

6' - 3"

7' - 0"

4' - 6"

76" Hole
(Sink 9")

6" 6"

12"

6' - 0"

12"

11' - 7"

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
(3.) All walls 6" thick.
NOTE:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Dimensions adapt to our forms.

TITLE

60" Headwall with Apron

STATE

GA

SECTION PAGE

3.17

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

9' - 4"
8"

3' - 4"

6"

"

5'

-0

8' - 1"

9' - 6"

5' - 0"

84" Hole
(Sink 9")

6" 6"

12"

7' - 6"

24"

13' - 0"

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
NOTE:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) Also available for 78'', 84" & 96" CMP.
TITLE

66" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.18

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

9' - 4"
8"

3' - 4"

6"

"

5'

-0

8' - 1"

9' - 6"

5' - 0"

90" Hole
(Sink 9")

6" 6"

12"

7' - 6"

24"

13' - 0"

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
NOTE:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Dimensions adapt to our forms.

TITLE

72" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.19

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

9' - 4"
8"

3' - 4"

6"

5'

0"

8' - 1"

9' - 6"

5' - 0"

105" Hole
(Sink 9")

6" 6"

12"

7' - 6"

24"

13' - 0"

Hole Normally Flush

Specifications
(1.) 4,000 p.s.i. concrete.
(2.) #4 @ 12" C/C
NOTE:

-No ScaleAll dimensions subject to allowable


specification tolerances.

(1.) Dimensions adapt to our forms.

TITLE

84" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.20

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'

-5

"

1' - 7"

6"

4' - 2"

6"

2' - 9"

12"

Specifications

3' - 9"
2' - 1"

22" H x 28" W

(Sink 2.5")

6" 6"

2' - 9"

11"

6' - 3"

(1.) 4,000 p.s.i. CONCRETE.


Hole Normally Flush

(2.) #4 @ 12" C/C

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) All walls 6" thick.
TITLE

12" x 18" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.21

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'-

11

"

2' - 0"

6"

4' - 9"

3' - 5"

12"

Specifications

4' - 4"
2' - 6"

24" H x 34" W
(Sink 2.75")

6" 6"

3' - 4"

12"

7' - 2"

(1.) 4,000 p.s.i. CONCRETE.


Hole Normally Flush

(2.) #4 @ 12" C/C

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) All walls 6" thick.
TITLE

14" x 23" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.22

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2'-

11

"

2' - 0"

4' - 9"

3' - 5"

4' - 4"
2' - 6"

30" H x 40" W
(Sink 3.25")

6" 6"

12"

3' -4"

12"

7' - 2"

Specifications

Hole Normally Flush

(1.) 4,000 p.s.i. CONCRETE.


(2.) #4 @ 12" C/C

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) Dimensions adapt to our forms.


(2.) All walls 6" thick.
TITLE

19" x 30" Headwall with Apron

STATE

SECTION PAGE

DATE

GA

3.23

12-01-10
HEIDELBERGCEMENT Group

Manholes

Note 6

6" Standard
(8" Available)

C.I. MH
Frame & Cover
(Typ.)

24" or 30"
Available

As Required

Shallow
(W / Alternate Slab Top)

As Required

12"
Typ.

Ref. Note 11.

"H"

5" Wall

48" I.D.

6' Base Available


to Rincon.

As Required

Base Section
2' - 0" to 4' - 0"

Riser
1' - 0" to 4' - 0"

2' thru 4' cone section

8" at Top

No Base

6"

See Note 10.

Section View
Materials & Features:
(1.) Manhole design specifications conform to latest ASTM C 478 specifications
for "Precast Reinforced Concrete Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements of ASTM C 478 and
shall utilize grade 60 re-bars conforming to the requirements of ASTM A 615
or WWF conforming to the requirements of ASTM A 185 or drawn wire
conforming to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene and meet the
requirements of ASTM C478. See Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade rings to be supplied
by Hanson or to be field adjusted, using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to be installed by
contractor. See Typical Manhole Pipe Connection Detail.
(8.) Cast iron ring and cover to be as per specifications supplied by either Hanson
or customer.
(9.) Joints to be sealed with preformed butyl rubber joint sealant meeting requirements of ASTM C 990. See Typical Manhole Section Joint Detail.
(10.) Regular base shown. Also available with extended base.
(11.) 16" spacing available as required.

Isometric View
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

4' Diameter
Precast Manhole

GA

4 .1

12-01-10
HEIDELBERGCEMENT Group

Manholes

8"

8"

8"

Detail "A"
Grade Rings

4"

See Note #7
See Note #7
See Note #6
4" Grade Rings
per Detail "A"

2' - 0"

2' - 0"
Dia.
5" Typ.
See Note #5
4' - 0" I.D.
4' - 10" O.D.

Isometric View

Section View
Materials & Features:
(1.) Manhole design specifications conform to latest ASTM C 478 specifications
for "Precast Reinforced Concrete Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements of ASTM C 478 and
shall utilize grade 60 re-bars conforming to the requirements of ASTM A 615
or WWF conforming to the requirements of ASTM A 185 or drawn wire
conforming to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene and meet the
requirements of ASTM C 478. See Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade rings to be supplied by
by Hanson or to be field adjusted, using approved methods, by contractor.
(7.) Cast iron ring and cover to be as per specifications supplied by either Hanson
or customer.

TITLE

4' Diameter Precast


Manhole Concentric Cone

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

4 .2

12-01-10
HEIDELBERGCEMENT Group

Manholes

8"

8"

8"

Detail "A"
Grade Rings

4"

See Note #8
See Note #8
See Note #7

2' - 0"

4" Grade Rings


per Detail "A"

2' - 0"
Dia.
See Note #6

4' - 0" I.D.


4' - 10" O.D.

Isometric View

Section View
Materials & Features:
(1.) Manhole design specifications conform to latest ASTM C 478 specifications
for "Precast Reinforced Concrete Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements of ASTM C 478 and
shall utilize grade 60 re-bars conforming to the requirements of ASTM A 615
or WWF conforming to the requirements of ASTM A 185 or drawn wire
conforming to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene and meet the
requirements of ASTM C 478. See Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade rings to be supplied by
Hanson or to be field adjusted, using approved methods, by contractor.
(7.) Cast iron ring and cover to be as per specifications supplied by either Hanson
or customer.

TITLE

4' Diameter Precast


Manhole Eccentric Cone

STATE

GA

-No ScaleAll dimensions subject to allowable


specification tolerances.

SECTION PAGE

4.3

DATE

12-01-10
HEIDELBERGCEMENT Group

Manholes
C.I. MH
Frame & Cover
(Typ.)

Note 7

24" or 30"
Available

6" Standard
(8" Available)

As Required

5" Cone not


Available in
Athens.

24" or 30" Available

Alternate Flat Top


12"
Typ.

As Required

Riser
1' - 0" to 6' - 8"

2', 3' or 4' Cone Section

8" at Top

Ref. Note 11.

6" Typ.

5'-0" Dia.

As Required

Base Section
2' - 0" to 6' - 0"

Max. Base Height


5' - 6" in Athens.

6" or 8"

See Note 10.

Section View
Materials & Features:
(1.) Manhole design specifications conform to latest ASTM C 478 specifications
for "Precast Reinforced Concrete Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements of ASTM C 478 and
shall utilize grade 60 re-bars conforming to the requirements of ASTM A 615
or WWF conforming to the requirements of ASTM A 185 or drawn wire
conforming to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene and meet the
requirements of ASTM C 478. See Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" grade rings to be supplied by
Hanson or to be field adjusted, using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to be installed by
contractor. See Typical Manhole Pipe Connection Detail.
(8.) Cast iron ring and cover to be as per specifications supplied by either Hanson
or customer.
(9.) Joints to be sealed with preformed butyl rubber joint sealant meeting requirements of ASTM C 990. See Typical Manhole Section Joint Detail.
(10.) Regular base shown. Also available with 7" extended base.
(11.) 16" Step Spacing Available as Required.
TITLE

5' Diameter Precast


Manhole

Isometric View

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

4.4

12-01-10
HEIDELBERGCEMENT Group

Manholes
6" Standard
(8" Available)

24" or 30" Available

Alternate Flat Top


C.I. MH
Frame & Cover
(Typ.)

As Required

2' Thru 4'

24" I.D.
or
30" I.D.
(30" I.D. Available
In 2' - 0" Cone Only.)

Cone Section

4" Grade Rings per


Detail "A" on Page 4.3

4'-0" Dia.

As Required

5" Typ.

Riser Sections

1' thru 4'

Isometric View

Reducer
Section

8"

See Note #7

As Required

5'-0" Dia.

As Required

See Note #9

1' thru 6'


Riser Sections

12"
Typ.

6" Typ.

2' thru 6'


Base Section

See Notes #5 & 10

Materials & Features:


(1.) Manhole design specifications conform to latest ASTM
C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A 615 or WWF conforming to
the requirements of ASTM A 185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade
rings to be supplied by Hanson or to be field adjusted,
using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
(10.) 16" step spacing available as required.

6" Std., 8" available


Extended Base Available

-No ScaleAll dimensions subject to allowable


specification tolerances.

7"

Section View
.

TITLE

STATE

SECTION PAGE

DATE

5' Diameter Precast


Manhole / Reduced

GA

4 .5

12-01-10
HEIDELBERGCEMENT Group

Manholes
6" Standard
(8" Available)

24" or 30" Available

Alternate Flat Top


C.I. MH
Frame & Cover
(Typ.)

As Required

2' Thru 4'

24" I.D.
or
30" I.D.
(30" I.D. Available
In 2' - 0" Cone Only.)

Cone Section

4" Grade Rings per


Detail "A" on Page 4.3

4'-0" Dia.

As Required

5" Typ.

Riser Sections

1' thru 4'

Isometric View

Reducer
Section

12"

See Note #7

As Required

6'-0" Dia.

As Required

See Note #11

1' thru 6'


Riser Sections

12"
Typ.

7" Typ.

1'-4" thru 6'


Base Section

See Note #6

Materials & Features:


(1.) Manhole design specifications conform to latest ASTM
C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A 615 or WWF conforming to
the requirements of ASTM A 185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade
rings to be supplied by Hanson or to be field adjusted,
using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
(10.) Regular base shown. Also available with extended base.
(11.) 16" step spacing available as req'd.

8"
7"

See Note 10.

-No ScaleAll dimensions subject to allowable


specification tolerances.

Section View
.

TITLE

STATE

SECTION PAGE

DATE

6' Diameter Precast


Manhole / Reduced

GA

4 .6

12-01-10
HEIDELBERGCEMENT Group

Manholes

12"

24" or 30" Available

Alternate Flat Top

C.I. MH
Frame & Cover
(Typ.)

As Required

(30" I.D. Available


In 2' - 0" Cone Only.)

Cone Section

24" I.D.
or
30" I.D.

2' Thru 4'

4" Grade Rings per


Detail "A" on Page 4.3

Riser Sections

As Required

As Required

As Required

1' thru 4'

1' thru 7'-6"


Riser Sections
2' thru 7'-6" Rincon
2' thru 6'-10 Athens
Base Section

Isometric View
5" Typ.
4'-0" Dia.

12"

8" Typ.
See Note #11

12"
Typ.

See Note #5

See Note #9

7'-0" Dia.

See Note #7

See Note 10.

Section View

Materials & Features:

(1.) Manhole design specifications conform to latest ASTM


C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A 615 or WWF conforming to
the requirements of ASTM A 185 or drawn wire conforming
Reducer
to the requirements of A82 or a combination thereof.
Section
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" grade rings
to be supplied by Hanson or to be field adjusted, using
approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
(10.) Regular base shown. Also available with 7" extended base.
(11.) 16" step spacing available as required.
8"

7"

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

7' Diameter Precast


Manhole / Reduced

GA

4 .7

12-01-10
HEIDELBERGCEMENT Group

Manholes
12"

24" or 30" Available

Alternate Flat Top

Cone Section

As Required
As Required

4'-0" Dia.

Riser Sections

9" Typ.

2' Thru 4'

24" I.D.
or
30" I.D.
(30" I.D. Available
In 2' - 0" Cone Only.)

1' thru 4'

C.I. MH
Frame & Cover
(Typ.)

Reducer
Section

12"

See Note #7

As Required

8'-0" Dia.

As Required

See Note #9

2' thru 8'


Riser Sections

See Note #11

2' thru 7'


Base Section

9" Typ.

12"
Typ.

See Note #5

12" *

See Note 10.

Section View

14"

Isometric View
Materials & Features:
(1.) Manhole design specifications conform to latest ASTM
C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A 615 or WWF conforming to
the requirements of ASTM A 185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade
rings to be supplied by Hanson or to be field adjusted,
using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
(10.) Regular base shown. Also available with extended base.
(11.) 16" step spacing available as required.
-No ScaleAll dimensions subject to allowable
specification tolerances.

- Reduction of base slab thickness increases base


*height
by same amount.
TITLE

8' Diameter Precast


Manhole / Reduced

STATE

SECTION PAGE

DATE

GA

4.8

12-01-10
HEIDELBERGCEMENT Group

Manholes

8"

24" or 30" Available

Alternate Flat Top

C.I. MH
Frame & Cover
(Typ.)

24" I.D.
or
30" I.D.
(30" I.D. Available
In 2' - 0" Cone Only.)

2' Thru 4'


Cone Section
As Required

4" Grade Rings per


Detail "A" on Page 4.3

4'-0" Dia.

15"

11" Typ.
See Note #11

12"
Typ.

See Note #5

10'-0" Dia.

See Note #7

See Note 10.

Section View
*-

(1.) Manhole design specifications conform to latest ASTM


C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
Reducer
to the requirements of ASTM A 615 or WWF conforming to
Section
the requirements of ASTM A 185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" or 6" grade
rings to be supplied by Hanson or to be field adjusted,
using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.)
Joints
to be sealed with preformed butyl rubber joint
12"
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
14" *
(10.) Regular base shown. Also available with extended base.
(11.) 16" step spacing available as required.
2' thru 5' - 6"
Base Section
As Required

See Note #9

Materials & Features:

1' thru 6'


Riser Sections
As Required

5" Typ.

1' thru 4'


Riser Sections
As Required

Isometric View

-No ScaleAll dimensions subject to allowable


specification tolerances.

Extended base square or octagonal only.

TITLE

STATE

SECTION PAGE

DATE

10' Diameter Precast


Manhole / Reduced

GA

4 .9

12-01-10
HEIDELBERGCEMENT Group

Manholes

8"

24" or 30" Available

Alternate Flat Top

C.I. MH
Frame & Cover
(Typ.)
24" I.D.
or
30" I.D.
(30" I.D. Available
In 2' - 0" Cone Only.)

2' Thru 4'


Cone Section
As Required

4" Grade Rings per


Detail "A" on Page 4.3

Isometric View

5" Typ.
4'-0" Dia.

1' thru 4'


Riser Sections
As Required

Materials & Features:

24"
Reducer
Section

18"

See Note #10

2' thru 5'


Base Section
As Required

See Note #9

1' thru 6'


Riser Sections
As Required

12" Typ.

12"
Typ.

See Note #5

12'-0" Dia.

See Note #7

12"

(1.) Manhole design specifications conform to latest ASTM


C 478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM C 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A 615 or WWF conforming to
the requirements of ASTM A 185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Designed for H-20 loading.
(5.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C 478. See
Typical Step Detail.
(6.) Contractor to adjust to grade as required. 4" & 6" grade
rings to be supplied by Hanson or to be field adjusted,
using approved methods, by contractor.
(7.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(8.) Cast iron ring and cover to be as per specifications
supplied by either Hanson or customer.
(9.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C 990. See
Typical Manhole Section Joint Detail.
(10.) 16" step spacing available as required.

Section View

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

12' Diameter Precast


Manhole / Reduced

GA

4.10

12-01-10
HEIDELBERGCEMENT Group

Manholes
1/ " Grade 60 Steel
2

12"

Reinforcement Copolymer
Polypropylene Plastic

10 3/ "
4

Section A-A

9 1/ "
8

1 1/4"

3 3/ "
8

1 1/8"

5 3/4"
Materials & Features:

12" Typ.
(Ref. Note 6)

(1.) Step design, installation, and material


shall meet the requirements of
ASTM C478.
(2.) Plastic material consists of super high
impact resistant copolymer
polypropylene and conform to
specific requirements as detailed
in ASTM D4101.
(3.) Reinforcing steel shall be 1/2 " rebar,
grade 60 and meet the requirements
of ASTM A615.
(4.) Step width and spacing are consistant
with the latest requirements of OSHA.
(5.) Manufacturer's literature available
upon request.
(6.) 16" spacing available.

1 1/8"

9 1/ "
8

3 3/ "
8

5 3/ "
4

Section B-B
B
11"

1"

12"

1/ " Grade 60 Steel


2
Reinforcement Copolymer
Polypropylene Plastic

TITLE

STATE

SECTION PAGE

DATE

Typical Manhole
Step Detail

GA

4.11

12-01-10
HEIDELBERGCEMENT Group

Manholes

Non-Shrink Grout
By Contractor

Isometric View

Note:
(1.) Pipe connection detail used shall be consistent with the Specific job requirements

as well as the pipe size and type, and the structure to be used
(2.) Rigid connections shall be made on site by the contractor and
-No ScaleAll dimensions subject to allowable
specification tolerances.

meet GDOT requirements for mortar joint connections.


.

TITLE

STATE

SECTION PAGE

DATE

Manhole Pipe Connection Detail


Grout Type - Rigid Connection

GA

4.12

12-01-10
HEIDELBERGCEMENT Group

Manholes

See Notes #3 & #4

Isometric View

Note:
(1.) Pipe connection detail used shall be consistent with the Specific job requirements

as well as the pipe size and type, and the structure to be used
(2.) Flexible connectors shall meet the requirements of ASTM C923 Specifications

for Resilient Connectors Between Reinforced Concrete Manhole Structures.


(3.) Compression rings, see literature.
(4.) Manufacture's literature available upon request.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Manhole Pipe Connection Detail


Boot Type - Flexible Connection

GA

4.13

12-01-10
HEIDELBERGCEMENT Group

Manholes

See Note 3

Isometric View

Note:
(1.) Pipe connection detail used shall be consistent with the Specific job requirements

as well as the pipe size and type, and the structure to be used
(2.) Flexible connectors shall meet the requirements of ASTM C923 Specifications

for Resilient Connectors Between Reinforced Concrete Manhole Structures.


(3.) Manufacture's literature available upon request.
(4.) Not available in all markets.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Manhole Pipe Connection Detail


Compression Gasket - Flexible Connection

GA

4.14

12-01-10
HEIDELBERGCEMENT Group

Manholes

Joint Depth
Annular Area

Wall Thickness

Section View

Basic Dimensions - Rincon Plant


Manhole
Diameter

Wall
Thickness

Joint
Depth

Butyl
Size

Annular
Area of
Joint

Butyl
Rubber
Area

% of
Fill In
Joint

LF of
Butyl
Rubber

Number
of Butyl
Rolls

48"
60"
72"

5"
6"
7"

4"
5"
5"

1"
1 1/4"
1 1/2"

0.531
0.893
1.50

0.785
1.23
1.77

148
138
118

14.5
17.5
20.5

1
1.5
2

84"
96"
120"

7"
8"
10"

5"
5"
5"

1"
1"
2"

0.625
0.496
2.5

0.785
0.785
3.14

126
167
126

24.0
27.5
34.5

2
3
4

Note:
(1.) Butly rubber section joint design conforms to latest

ASTM C 478 specifications.


(2.) Buty rubber sealant conforms to ASTM C 990. AASHTO M-198
-No ScaleAll dimensions subject to allowable
specification tolerances.

and federal specifications.


(3.) Manufacture's literature available upon request.
.

TITLE

STATE

SECTION PAGE

DATE

Typical Manhole
Section Joint Detail - Rincon

GA

4.15

12-01-10
HEIDELBERGCEMENT Group

Manholes

Joint Depth
Annular Area

Wall Thickness

Section View

Basic Dimensions - Athens Plant


Manhole
Diameter

Wall
Thickness

Joint
Depth

Butyl
Size

Annular
Area of
Joint

Butyl
Rubber
Area

% of
Fill In
Joint

LF of
Butyl
Rubber

Number
of Butyl
Rolls

48"
60"
72"

5"
6"
7"

4"
6"
6"

1"
1 1/4"
1 1/2"

0.531
0.893
1.50

0.785
1.23
1.77

148
138
118

14.5
17.5
20.5

1
1.5
2

84"
96"
120"

8"
9"
11"

7"
6"
6"

1"
1"
2"

0.625
0.496
2.5

0.785
0.785
3.14

126
167
126

24.0
27.5
34.5

2
3
4

Note:
(1.) Butly rubber section joint design conforms to latest

ASTM C 478 specifications.


(2.) Buty rubber sealant conforms to ASTM C 990. AASHTO M-198
-No ScaleAll dimensions subject to allowable
specification tolerances.

and federal specifications.


(3.) Manufacture's literature available upon request.
.

TITLE

STATE

SECTION PAGE

DATE

Typical Manhole
Section Joint Detail - Athens

GA

4.16

12-01-10
HEIDELBERGCEMENT Group

Manholes

Grade Rings: 4" & 6" Heights

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

4'
4'
4'
4'
4'

Cone
Cone
Cone
Flat Top
Flat Top

2.0
3.0
4.0
0.50 Std.
0.67 (Avail.)

1,800
2,700
3,500
2,100
2,100

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

4'
4'
4'
4'
4'

Riser
Riser
Riser
Riser
Riser

1.0
1.33
2.0
2.67
4.0

900
1,200
1,800
2,400
3,500

Athens Stock Heights (Ft.): 1.0, 2.0, 3.0 & 4.0

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

4'
4'
4'
4'
4'
4'
4'
4'
4'
4'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
2.67
2.67
3.0
3.0
4.0
4.0

2,500
3,200
3,100
3,800
3,700
4,400
4,000
4,600
4,900
5,500

Athens Stocks 18" - 72" Diameters in 6" Increments.


Note:
(1.) Above base weights do not include precast inverts.
(2.) Can make any height needed.

Isometric View
of Components

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

4' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.17

12-01-10
HEIDELBERGCEMENT Group

Manholes

All Product Made to Order; None Stocked.

Dia./Ft.

Section

Height/Ft.

5'
5'/4'

Flat Top
Adapter

Dia./Ft.

Section

5'
5'
5'
5'
5'
5'
5'
5'

Riser
Riser
Riser
Riser
Riser
Riser
Riser
Riser

1.0
1.33
2.0
2.67
3.0
4.0
5.0
6.0

1,300
1,700
2,500
3,400
3,900
5,100
6,500
7,800

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

5'
5'
5'
5'
5'
5'
5'
5'
5'
5'
5'
5'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
3.0
3.0
4.0
4.0
5.0
5.0
6.0
6.0

0.67
0.67

Height/Ft.

Weight/ Lbs.
3,400
3,400

Weight/ Lbs.

4,500
6,000
5,400
6,800
6,700
8,100
8,000
9,300
9,200
10,600
10,500
11,900

Note:
(1.) Above base weights do not include precast inverts.

Isometric View
of Components

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

5' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.18

12-01-10
HEIDELBERGCEMENT Group

Manholes

All Product Made to Order; None Stocked.


Dia./Ft.

Section

Height/Ft.

6'
6'/4'

Flat Top
Adapter

Dia./Ft.

Section

Height/Ft.

6'
6'
6'
6'
6'
6'

Riser
Riser
Riser
Riser
Riser
Riser

1.0
2.0
3.0
4.0
5.0
6.0

Dia./Ft.

Section

Height/Ft.

6'
6'
6'
6'
6'
6'
6'
6'
6'
6'
6'
6'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
3.0
3.0
4.0
4.0
5.0
5.0
6.0
6.0

0.67
1.0

Weight/ Lbs.
4,900
6,800

Weight/ Lbs.
1,800
3,500
5,300
7,100
8,900
10,600

Weight/ Lbs.
6,400
7,500
7,500
8,700
9,300
10,500
11,100
12,300
12,800
14,000

Note:
(1.) Above base weights do not include precast inverts.
(2.) Risers & Bases can be made to any height.

Isometric View
of Components

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

6' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.19

12-01-10
HEIDELBERGCEMENT Group

Manholes

All Product Made to Order; None Stocked.

Isometric View
of Components

Dia./Ft.

Section

Height/Ft.

7'
7'/4'

Flat Top
Adapter

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

7'
7'
7'
7'

Riser
Riser
Riser
Riser

2.0
3.0
4.0
5.0

4,100
6,100
8,200
10,200

7'
7'
7'

Riser
Riser
Riser

6.0
7.0
7.5

12,300
14,300
15,400

0.67
1.0

Dia./Ft.

Section

Height/Ft.

7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'
7'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
3.0
3.0
4.0
4.0
5.0
5.0
6.0
6.0
7.0
7.0

Weight/ Lbs.
6,000
8,600

Weight/ Lbs.
8,000
9,500
9,300
10,900
11,300
12,900
13,400
15,000
15,400
17,000
17,400
19,000
19,500
21,100

Note:
(1.) Above base weights do not include precast inverts.
(2.) Risers available any size between 24" - 72".
(3.) Bases available any size up to 84".
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

7' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.20

12-01-10
HEIDELBERGCEMENT Group

Manholes

All Product Made to Order; None Stocked.


Dia./Ft.

Section

Height/Ft.

8'
8'/4'

Flat Top
Adapter

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

8'
8'
8'
8'
8'
8'
8'

Riser
Riser
Riser
Riser
Riser
Riser
Riser

2.0
3.0
4.0
5.0
6.0
7.0
8.0

5,400
8,200
10,900
13,600
16,300
18,900
21,600

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'
8'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
3.0
3.0
4.0
4.0
5.0
5.0
6.0
6.0
7.0
7.0

10,400
14,200
12,200
16,000
15,000
18,800
17,700
21,500
20,400
24,200

0.67
1.0

Weight/ Lbs.
8,000
11,300

Note:
(1.) Above base weights do not include precast inverts.
(2.) Risers available any size between 24" - 96".
(3.) Bases available any size between 24" - 84".

Isometric View
of Components

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

8' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.21

12-01-10
HEIDELBERGCEMENT Group

Manholes

All Product Made to Order; None Stocked.


Dia./Ft.

Section

Height/Ft.

10'
10'/4'

Flat Top
Adapter

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

10'
10'
10'
10'
10'

Riser
Riser
Riser
Riser
Riser

2.0
3.0
4.0
5.0
6.0

8,400
12,600
16,800
21,000
25,200

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

10'
10'
10'
10'
10'
10'
10'
10'
10'
10'

Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base
Base
Extended Base

1.33
1.33
2.0
2.0
3.0
3.0
4.0
4.0
5.0
5.0

21,400
25,300
24,200
28,100
28,400
32,300
32,600
36,500
36,800
40,500

0.67
1.25

Weight/ Lbs.
12,400
21,500

Note:
(1.) Above base weights do not include precast inverts.
(2.) Risers available any size between 24" - 72".
(3.) Bases available any size between 24" - 60".
(4.) All extended bases square or octogonal.

Isometric View
of Components
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

10' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.22

12-01-10
HEIDELBERGCEMENT Group

Manholes

Must bring form in from GCS


Dia./Ft.

Section

Height/Ft.

12'
12'/4'

Flat Top
Adapter

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

12'
12'
12'
12'
12'
12'

Riser
Riser
Riser
Riser
Riser
Riser

1.0
2.0
3.0
4.0
5.0
6.0

6,000
12,100
18,100
24,200
30,200
36,200

Dia./Ft.

Section

Height/Ft.

Weight/ Lbs.

12'
12'
12'
12'
12'

Base
Base
Base
Base
Base

1.33
2.0
3.0
4.0
5.0

30,800
34,900
40,900
47,000
53,000

0.83
1.50

Weight/ Lbs.
25,100
21,500

Note:
Above base weights do not include precast inverts.

Isometric View
of Components

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

12' Diameter Manhole


Product Information Sheet

STATE

SECTION PAGE

DATE

GA

4.23

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

Isometric View

10"

Materials & Features:

6"

1' thru 4'


Riser Sections
As Required

4'-0" Dia.

12" Typ.

See Note #12


5" Typ.

2' thru 6'


Base Section
As Required

See Note #10


See Note #6

See Note #8
6"
4'-10" O.D.
See Note #11

Section View

7"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with 7" extended
base.
(12.) 16" step spacing available.
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

4' Diameter Precast


Wet Well

GA

5.1

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

Isometric View
14"

Materials & Features:

8"

1' thru 6'


Riser Sections
As Required

5'-0" Dia.

12" Typ.

See Note #12


6" Typ.

2' thru 66"


Base Section
As Required

See Note #10


See Note #6

See Note #8
6"
6'-0" O.D.
See Note #11

Section View

7"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with extended 7" base.
(12.) 16" step spacing available.
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

5' Diameter Precast


Wet Well

GA

5 .2

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

Isometric View
14"

8"

Materials & Features:

2' thru 6'


Riser Sections
As Required

6'-0" Dia.

12" Typ.
See Note 12
7" Typ.

2' thru 6'


Base Section
As Required

See Note #10


See Note #6

See Note #8
6"
7'-2" O.D.
See Note #11

Section View

7"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with extended 7" base.
(12.) 16" step spacing available.
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

6' Diameter Precast


Wet Well

GA

5 .3

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

Isometric View
15"

8"

Materials & Features:

2' thru 90"


Riser Sections
As Required

7'-0" Dia.
8" Typ.
12" Typ.
See Note #12

2' thru 82"


Base Section
As Required

See Note #10

See Note #6

See Note #8
8"
100" O.D.
See Note #11

7"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with extended base.
(12.) 16" step spacing available.

Section View

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

7' Diameter Precast


Wet Well

GA

5 .4

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

Isometric View
14"

8"

Materials & Features:


8'-0" Dia.

2' thru 8'


Riser Sections
As Required

9" Typ.
12" Typ.
See Note #12

2' thru 88"


Base Section
As Required

See Note #10

See Note #6
See Note #8

8"
114" O.D.
See Note #11

Section View

14"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with extended base.
(12.) 16" step spacing available.
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

8' Diameter Precast


Wet Well

STATE

SECTION PAGE

DATE

GA

5.5

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

Isometric View

See Note #9

Materials & Features:


14"

8"

1' thru 6'


Riser Sections
As Required

10'-0" Dia.
11" Typ.
12" Typ.
See Note #12

1' thru 5'


Base Section
As Required

See Note #10

See Note #6

See Note #8

12"
142" O.D.
See Notes #11 & #13

8"

(1.) Manhole design specifications conform to latest ASTM


C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) Regular base shown. Also available with extended base.
(12.) 16" step spacing available.
(13.) Extended bases must be square or octagonal.

Section View

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

10' Diameter Precast


Wet Well

GA

5 .6

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

See Note #9

16"

Isometric View

10"

1' thru 6'


Riser Sections
As Required

12'-0" Dia.
12" Typ.
12" Typ.
See Note #11

1' thru 5'


Base Section
As Required

See Note #10

See Note #6

See Note #8

12"
14'-0" O.D.

Section View

Materials & Features:


(1.) Manhole design specifications conform to latest ASTM
C478 specifications for "Precast Reinforced Concrete
Manhole Sections".
(2.) Concrete compressive strength 4,000 psi min.
(3.) Steel reinforcing designed to conform to the requirements
of ASTM 478 and shall utilize grade 60 re-bars conforming
to the requirements of ASTM A615 or WWF conforming to
the requirements of ASTM A185 or drawn wire conforming
to the requirements of A82 or a combination thereof.
(4.) Additional reinforcing at openings.
(5.) Designed for H-20 loading.
(6.) Steps shall be steel reinforced copolymer polypropylene
and meet the requirements of ASTM C478. See
Typical Step Detail.
(7.) Total Height per job specifications.
(8.) Pipe penetration to be as per job requirements. Pipe to
be installed by contractor. See Typical Manhole Pipe
Connection Detail.
(9.) Cast in hatch to be as per specifications, supplied by
either Hanson or customer.
(10.) Joints to be sealed with preformed butyl rubber joint
sealant meeting requirements of ASTM C990. See
Typical Manhole Section Joint Detail.
(11.) 16" step spacing available.
-No ScaleAll dimensions subject to allowable
specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

12' Diameter Precast


Wet Well

GA

5 .7

12-01-10
HEIDELBERGCEMENT Group

Wet Wells

6"
Min.

Varies

6"

6"
min.

Varies

min.

Hatch Cast in as Specified

Varies
14' - 0" Max. Width

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

Rectangular or Square Wetwells


Various Sizes

STATE

SECTION PAGE

DATE

GA

5.8

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6"

6"

6"

6"

Product Dimensions
A

2' - 0"

2' - 0"

2' - 0"

2' - 0"

3' - 0"

3' - 0"

2' - 0"

3' - 0"

4' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

3' - 0"

4' - 0"

3' - 0"

4' - 0"

4' - 0"

4' - 0"

4' - 0"

4' - 0"

Materials
CONCRETE: 4,000 PSI, Type II cement.
WALL REINFORCING:
2 ea. #5 bars each corner.
1 ea. continuous #5 around top.

6"

BOTTOM SLAB REINFORCING:


#5 @ 12" O.C.E.W.*
NOTE:
* All Reinforcement to be Grade 40, or equivalent welded wire mesh.

Grate Information
U.S.F. NO.

TYPE

RATING

FLOW AREA
(SQ. IN.)
-No ScaleAll dimensions subject to allowable
specification tolerances.

Contact Hanson Pipe & Products for available castings for each
size box.
TITLE

Knock-out Boxes

STATE

SECTION PAGE

DATE

GA

6 .1

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Varies

Varies

Varies

Varies

Varies

Optional
Top

Varies

As Required

Product Specifications
Square and Rectangular Structures are available upon request.

Varies

4"

Inside dimensions, wall thickness, slab thickness and


reinforcement per requirements.
Note:
Contact local plant for available sizes.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

Large Rectangular Storm Structures

STATE

GA

SECTION PAGE

6 .2

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

As Specified
Brick Adjustment
See Note **

24" or 32"

Varies
B

Product Dimensions
A

4' - 0"

5"

6"

ASTM C-478

5' - 0"

6"

6" or 8"

ASTM C-478

6' - 0"

7"

6" or 8"

ASTM C-478

8' - 0"

9"

*12"

ASTM C-478

10' - 0"

11"

*12"

ASTM C-478

12' - 0"

12"

*12"

ASTM C-478

Materials
CONCRETE: 4,000 PSI.
WALL REINFORCING:
per ASTM C-478 Standard.
NOTE:
(a) All reinforcement to be Grade 40, or equivalent welded wire mesh.
(b) All reinforcement as required per design.
(c) 144" form in Florida can be borrowed for production.
(d) All Reinforcement to be Grade 40, or equivalent welded wire mesh.
* Base slab thickness as required - Can be seperate spigoted base or
monolithic using secondary pour.
** Variable grade adjustment by grade rings or brick as required.

TITLE

Storm Manhole, 48" - 144" Diameter


with Topslab

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6 .3

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2 - #6
(Typ.)
Additional
Reinforcing Bars
As Specified
Brick Adjustment
See Note **

10"

24" or 32"

48"

See note (c)

14"

Varies

D
A

Varies

Product Dimensions

5' - 0"

6"

8"

ASTM C-478

6' - 0"

7"

8"

ASTM C-478

8' - 0"

9"

*12"

ASTM C-478

10' - 0"

12"

*12"

ASTM C-478

12' - 0"

12"

*12"

ASTM C-478

Materials
CONCRETE: 4,000 PSI, Type II cement.
WALL REINFORCING:
per ASTM C-478 Standard.
NOTE:
(a) All Reinforcement to be Grade 40, or equivalent welded wire mesh.
(b) All reinforcement as required per design.
(c) 5" min. wall for 48".
* Base slab thickness as required - Can be seperate spigoted base or
monolithic using secondary pour.
** Variable grade adjustment by grade rings or brick as required.
TITLE

Storm Manhole
Reducer Type with Topslab

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6 .4

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2 - #6 (Typ.)
Additional
Reinforcing Bars

As Specified
Brick Adjustment
See Note **

24"

Varies
D
See note (b)

14"

Varies

48"

D
A

Product Dimensions
A

5' - 0"

6"

8"

ASTM C-478

6' - 0"

7"

8"

ASTM C-478

8' - 0"

9"

*12"

ASTM C-478.

10' - 0"

12"

*12"

ASTM C-478

12' - 0"

12"

*12"

ASTM C-478

Varies

Materials
CONCRETE: 4,000 PSI, Type II cement.
WALL REINFORCING:
per ASTM C-478 Standard.
NOTE:
(a)
(b)
(c)
*

All Reinforcement to be Grade 40, or equivalent, welded wire mesh.


5" min. wall for 48".
All reinforcement as required per design.
Base slab thickness as required - Can be seperate spigoted base or
monolithic using secondary pour.
** Variable grade adjustment by grade rings or brick as required.
TITLE

Storm Manhole
Reducer Type with Cone

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6 .5

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

24
"

#6 @ 5" C/C
(Typ. Unless Noted)

2"

2"

2 Ea. - #6 Bars
(Typ. 2" Around Opening)
#4 Ring
Top & Bottom

24"

2"

8"

Brick Adjustment
See Note **

1 1/2"

8"

Top Slab - 1840#

2"

58"

4,000 p.s.i. CONCRETE.

5"

48"

2 ea. #5 bars
at each hole.

Varies

Materials

1 1/2"

WALL REINFORCING:
per ASTM C-478 Standard w/ #5 as shown.

TOP SLAB REINFORCING:


#6 @ 5" O.C.E.W. w/ #4 hoop at perimeter.

8"

BOTTOM SLAB REINFORCING:


#5 @ 12" O.C.E.W.

1' - 0"

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) All reinforcement to be grade 60 rebar.
(c.) Steps @ 12" O.C. as required.
** Variable grade adjustment by grade rings or brick as required.

TITLE

48" Dia. GDOT 1011A Manhole

-No ScaleAll dimensions subject to allowable


specification tolerances.
STATE

GA

SECTION PAGE

6 .6

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

North

Not Project

6"

6"

3' - 0"
23 1/4"

12 3/8"

8.5"
8.5"

6"

31"

3' - 0"

6"

12 3/8"

Top Slab - 1,500#

Varies

1 1/2"

8"

USF #4607-6151 Cast-In

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
3 x 4 W3.1 / W4.1 WWF - 65 KSI

6"

BOTTOM SLAB REINFORCING:


#4 @ 12" O.C.E.W.
TOP SLAB REINFORCING:
#4 @ 6" O.C.E.W.

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Steps @ 12" O.C. as required.
(c.) Extended base can be provided if required by design.
TITLE

3' x 3' GDOT 1019A Drop Inlet

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6 .7

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

23 1/4"

15.5"

31"

15.5"

11 5/8" 11 5/8"

Top Slab - 1,700#


USF #4607-6151 Cast-In

Varies

Materials
4,000 p.s.i. CONCRETE.

48"

5"

1 1/2"

WALL REINFORCING:
ASTM C-478

6"

BOTTOM SLAB REINFORCING:


#4 @ 9" O.C.E.W.

2 ea. #5 Bars at Each Hole

8"

58"

TOP SLAB REINFORCING:


#6 @ 6" O.C.E.W. w/ 6 ea.#8 diag.
bars around opening.
NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Steps @ 12" C/C as required.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

48" Dia. GDOT 1019A Drop Inlet

STATE

SECTION PAGE

DATE

GA

6 .8

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

2' - 0"

6"

6"

2' - 0"

6"

6"

USF #5151-6151
GaDOT FGH

Varies

Brick Adjustment
See Note **

Materials

2"

4,000 p.s.i. CONCRETE.


WALL REINFORCING:
#4 @12" O.C.E.W. w/ additional #4 as shown.

6"

2"

BOTTOM SLAB REINFORCING:


#4 @ 12" O.C.E.W.

18"

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) ATHENS - 48" MAX. BASE HEIGHT; USE OF RISERS
FOR TALLER STRUCTURES.
** Variable grade adjustment by brick as required.

#4 Bar 18"

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

2' x 2' GDOT 1019A Type E Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.9

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

24"

58"

24"

Top Slab - 1,440#

USF #5151-6151
GaDOT FGH

2 ea. #5 Bars at Each Hole

Varies

8"

Brick Adjustment
See Note **

48"

5"

Materials
1 1/2"

4,000 p.s.i. CONCRETE.


WALL REINFORCING:
ASTM C-478
6"

BOTTOM SLAB REINFORCING:


#4 @ 9" O.C.E.W.
TOP SLAB REINFORCING:
#4 @ 9" O.C.E.W. w/ 2 ea. #6
(4 sides) around opening.

1' - 0"

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Steps @ 12" C/C as required.
** Variable grade adjustment by brick as required.
TITLE

48" Dia. GDOT 1019A Type E Curb Inlet

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.10

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


6"

3 x 4 W3.1 / 4.1 WWF

2"
36"

2"

36"

2"

8 ea. #3 Bars

48"

Top Slab - Ref: Note (c)


Reducer Slab - 1,080#

8"

24"
Field Pour
Adjustment

36" x 36" Opng.


2"

2"

58"

5"

48"

WALL REINFORCING:
per ASTM C-478 Standard w/ #5 as shown.

2 ea. #5 bars
at each hole.

4,000 p.s.i. CONCRETE.

Varies

Materials

1 1/2"

BOTTOM SLAB REINFORCING


#5 @ 12" O.C.E.W.

6"

REDUCER SLAB REINFORCING


#6 @ 6" O.C.E.W. w/6 ea. #8 diagonal
bars around opening.
NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Steps @ 12" C/C as required.
(c.) 1 ea. #Top, Type 1033D, Rgt. w/USF1258-BD, GDOT, R & C
1 ea. #Top, Type 1033D, Lft. w/USF1258-BD, GDOT, R & C
1 ea. #Top, Type 1034D, w/USF1258-BD, GDOT, R & C

TITLE

48" Dia. GDOT 1033D / 1034D Curb Inlet

1' - 0"

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.11

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3' - 0"

6"

6"

3' - 0"

6"

6"

Top Slab - See Note (c)


24"
Field Pour
Adjustment

Materials
WALL REINFORCING:
3 x 4 W3.1 / W4.1 WWF - 65 KSI.

Varies

4,000 p.s.i. CONCRETE.

BOTTOM SLAB REINFORCING:


#4 @ 12" O.C.E.W.

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) 48" MAX BASE HEIGHT; DEEPER REQUIRES USE OF RISERS.
(b.) Steps @ 12" C/C as required.
(c.) 1 ea. #Top, Type 1033D, Rgt. w/USF1258-BD, GDOT, R & C
1 ea. #Top, Type 1033D, Lft. w/USF1258-BD, GDOT, R & C
1 ea. #Top, Type 1034D, w/USF1258-BD, GDOT, R & C

TITLE

3' x 3' GDOT 1033D / 1034D Inlet

6"

TOP SLAB REINFORCING:


See Top Slab details; Section.Page: 3.15, 3.16 & 3.17.

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.12

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


12' - 2"
4' - 0"

8' - 2"
2' - 0"

2' - 0"

4 ea. #5 Bars Around Opening


5 ea. #3 x 2' - 10 1/2" @ 3" Ctrs.

1' - 8"

5 ea. #3 x 4' - 0" @ 3" Ctrs.

2' - 4"

4' - 0"

6"

9"

3' - 9"

Plan View

1 1/2" CLR

USF #1258-BD Vented GDOT R/C Cast-In

1 1/2" CLR

6"

#5 @ 6" OCEW

1 1/2"
Typ.

Section AA
"W"

6"

Materials

1/ "
2

#5 @ 6" O.C.E.W.

Chamfer

4,000 p.s.i. Concrete.

1 1/2"

1 1/2"

1/ "
8

Smooth Form Finish

6"

1"

1 1/2"

Broom Finish

4 1/2"

5 ea ~ #3 @ 3" C/C

Nosing Detail
NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Weight: 2,340 lbs.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT 1033D - Left Top Slab

STATE

SECTION PAGE

DATE

GA

6.13

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


12' - 2"
4' - 0"
2' - 0"

8' - 2"
2' - 0"
4 ea. #5 Bars Around Opening

5 ea. #3 x 4' - 0" @ 3" Ctrs.

2' - 4"

4' - 0"

1' - 8"

5 ea. #3 x 2' - 10 1/2" @ 3" Ctrs.

6"

9"

3' - 9"

Plan View

1 1/2" CLR

USF #1258-BD Vented GDOT R/C Cast-In

1 1/2" CLR

6"

#5 @ 6" OCEW

1 1/2"
Typ.

Section AA

"W"

6"

Materials

1/ "
2

#5 @ 6" O.C.E.W.

4,000 p.s.i. CONCRETE.

Chamfer

1 1/2"

1 1/2"

1/ "
8

Smooth Form Finish

6"

1"

1 1/2"

Broom Finish

4 1/2"

5 ea ~ #3 @ 3" C/C

Nosing Detail

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Weight: 2,340 lbs.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT 1033D - Right Top Slab

STATE

SECTION PAGE

DATE

GA

6.14

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


12' - 8"
4' - 4"

4' - 0"
2' - 0"

4' - 4"
2' - 0"

1' - 10"

6"

4' - 0"

1' - 8"

4 ea. #5 Bars
Around Opening

4' - 7"

3' - 6"

4' - 7"

5 ea. #3 x 7' - 8" @ 3" Ctrs.


5 ea. #3 x 2' - 10 1/2" @ 3" Ctrs. (Typ. Both Sides)

Plan View
#5 @ 6" OCEW

1 1/2" CLR

Section AA
"W"

6"
1"
Smooth Form Finish

Materials

1/ "
2

#5 @ 6" O.C.E.W.

4,000 p.s.i. CONCRETE.

Chamfer

1 1/2"

1 1/2"

1/ "
8

1 1/2"

Broom Finish

6"

5 ea ~ #3 @ 3" C/C

4 1/2"

1 1/2" CLR

6"

USF #1258-BD Vented


GDOT R/C Cast-In

Nosing Detail

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Weight: 2,420 lbs.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT 1034D - Top Slab

STATE

SECTION PAGE

DATE

GA

6.15

12-01-10
HEIDELBERGCEMENT Group

2 ea. #5 Bars
@ ea. Hole

Varies

(b.)

9 1/2"

Precast Drainage Structures

48"

1 1/2" CLR.

5"

Materials
WALL REINFORCING:
ASTM C-478 w/ #5 as shown.

6"
or
8"

4,000 p.s.i. CONCRETE.

12"

BOTTOM SLAB REINFORCING:


#5 @ 8" O.C.E.W.

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Top, Type 9031-S, GDOT, Single Weir.
Top, Type 9031-S, GDOT, Double Weir.

TITLE

48" Dia. GDOT 9031-S Inlet

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.16

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

North

Not Project

2' - 0"

6"

(b.)

9 1/2"

6"

2' - 0"

6"

6"

Varies

Materials
4,000 p.s.i. CONCRETE.

2"

WALL REINFORCING:
#4 @ 12" O.C.E.W., w/additional #4 as shown.

6"

2"

BOTTOM SLAB REINFORCING:


#4 @ 12" O.C.E.W.

TITLE

2' x 2' GDOT 9031-S Drop Inlet

18"

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) 48" HEIGHT ON BASES; DEEPER STRUCTURES
REQUIRE RISERS.
(c.) Top, Type 9031-S, GDOT, Single Weir.
Top, Type 9031-S, GDOT, Double Weir.

#4 Bar 18"

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.17

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6' - 0"
1' - 6"

6"

1' - 0"

2' - 0"

6"

1' - 6"

2' - 0"

6' - 0"

6"

1' - 6"

1/ "
2

(Typ.)

3"

3"

(Typ.)

1' - 6"

6"

Steel Plate - Bolted


4 Places w/ 1/2" x 6" Bolt,
Nut & Washer - Galv.

8"

3' - 0"

8"
3"

1' - 6"

6"

1' - 6"

2' - 0"

2"

10 1/2"

3"
7 1/2"

10 1/2"

2' - 0"

Section A-A

2' - 0"

6"

9 1/2"

1"

2 1/2"

Top Elev.

6"

4 1/2"

9 1/2"
2' - 0"

2' - 0"

3' - 0"

Holes
(4 ea. - Typ.)

3 x 3 x 1/2" Steel Plate

7 1/2"

12"

5/ "
8

2' - 0"

2' - 0"

Section B-B

Specifications
STEEL: PER GDOT REQUIREMENTS.
4,000 p.s.i. CONCRETE.
GA-D.O.T. GRANITE ROCK REQUIRED.
-No ScaleAll dimensions subject to allowable
specification tolerances.

WEIGHT: 3,216 Lbs.

TITLE

GDOT Type 9031-S Single Weir Top Slab

STATE

SECTION PAGE

DATE

GA

6.18

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6' - 0"
1' - 6"

6"

1' - 0"

2' - 0"

6"

1' - 6"

2' - 0"

6' - 0"

6"

1' - 6"

1/ "
2

(Typ.)

3"

3"

(Typ.)

1' - 6"

6"

Steel Plate - Bolted


4 Places w/ 1/2" x 6" Bolt,
Nut & Washer - Galv.

5/ "
8

8"

3 x 3 x 1/2" Steel Plate

6"

3"

6"

1' - 6"

2' - 0"

10 1/2"

2"

9 1/2"

3"

2' - 0"

Section A-A

2' - 0"

6"

7 1/2"

2' - 0"

2' - 0"

1' - 6"

10 1/2"

2 1/2"

3' - 0"

1"

8"

9 1/2"

Top Elev.

3' - 0"

Holes
(4 ea. - Typ.)

2' - 0"

2' - 0"

Section B-B

Specifications
STEEL: PER GDOT SPECIFICATION.
4,000 p.s.i. CONCRETE.
GA-D.O.T. GRANITE ROCK REQUIRED.

-No ScaleAll dimensions subject to allowable


specification tolerances.

WEIGHT: 3,216 Lbs.


TITLE

GDOT Type 9031-S Double Weir Top Slab

STATE

GA

SECTION PAGE

6.19

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Varies

6"

6"

Varies

6"

6"

3" Deep x 3" Wide Recess


Around Interior - Top Wall
Grate Not Shown

Varies

3"

3"

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
#4 @ 12" O.C.E.W. or Equivalent WWF.
BOTTOM SLAB REINFORCING:
#4 @ 12" O.C.E.W.

6"

TOP SLAB REINFORCING:


N/A

NOTE:
(a.) GRANITE ROCK REQUIRED.
(b.) Steps @ 12" C/C as required.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT Ditch Drop Inlet

STATE

SECTION PAGE

DATE

GA

6.20

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


5' - 0"

6"

6"

24" Hole

2' - 0"

6"

6"

3"

3" x 3" Recess N & S Walls


Ref: Section B-B

4" D x 24" W Slot

3"

Recess at Inside Walls


North & South
3"

Plan View

Inside Wall
7 "
5' - 6 / 8

30"

4"

15"

6"

19"

3"

11"

Section B-B

Section AA
Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
#4 @ 12" O.C.E.W. or Equivalent WWF.
BOTTOM SLAB REINFORCING:
#4 @ 12" O.C.E.W.
TOP SLAB REINFORCING:
N/A

NOTE:
(a.) GRANITE ROCK REQUIRED.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

GDOT Median Drop Inlet for 15" Pipe

STATE

SECTION PAGE

DATE

GA

6.21

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Solid Slab w/Lifter


Weight: 2,180 lbs.

8"

Lifter

2"

58"

5"

Materials
4,000 p.s.i. CONCRETE.

2 ea. #5 bars
at each hole.

Varies

48"

WALL REINFORCING:
per ASTM C-478 Standard w/ #5 as shown.
1 1/2"

BOTTOM SLAB REINFORCING


#5 @ 12" O.C.E.W.
6"
or
8"

TOP SLAB REINFORCING


#4 @ 12" O.C.E.W.

1' - 0"
NOTE:

(a.) GRANITE ROCK REQUIRED - GA. DOT.


(b.) Steps @ 12" C/C as required.

TITLE

48" Dia. GDOT 9031-U Junction Box

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.22

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

4' - 0"

6"

3' - 0"

6"

6"

4 1/2"

6"

8" Deep x 5' - 0" Wide Slot

Varies

8"

Ref: Topslab Detailed on


Section.Page 6.24.

Materials
4,000 p.s.i. CONCRETE.

6"

WALL REINFORCING:
#4 @ 8" O.C.E.W. or equivalent WWF.
BOTTOM SLAB REINFORCING
#4 @ 8" O.C.E.W.
TOP SLAB REINFORCING
#4 @ 9" O.C.E.W.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

3' x 4' Savannah Type "A" Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.23

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


5' - 5"
32 1/2"

26 1/2"

4' - 5"

26 1/2"

32 1/2"

Plan View

4 1/2"

USF# 1259-BP "Storm" R/C (Cast-In)

24"

Section AA

1"

4 1/2"

1" Radius

Specifications
(1.) STEEL: #4 @ 9" O.C.E.W.

3/

(2.) 4,000 psi Concrete.


(3.) Chamfer all exposed edges 3/4".

4"

Chamfer

Nosing Detail

(4.) WEIGHT: 1,164 Lbs.


-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Savannah Type "A"


Top Slab for Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.24

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Not Project North


(Back of Curb)
3' - 0"

6"

6"

4' - 0"

8" Deep x 5' - 0" Wide Slot

6"

6"

9" to 14" Deep x 2' - 6" Wide Slot

Materials

8"

Varies

Varies

14"

9"

4 1/2"

Ref: Topslab Detailed on


Section.Page 3.28.

4,000 p.s.i. CONCRETE.


WALL REINFORCING:
#4 @ 8" O.C.E.W. or equivalent WWF.

6"

BOTTOM SLAB REINFORCING


#4 @ 8" O.C.E.W.
TOP SLAB REINFORCING
#4 @ 9" O.C.E.W.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

3' x 4' Savannah Type "B" Left Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.25

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

9' - 9"
4' - 4"

5' - 5"
32 1/2"

26 1/2"

32 1/2"

26 1/2"

4' - 5"

3' - 11"

6"

Plan View

4 1/2"

USF# 1259-BP "Storm" R/C (Cast-In)

24"

Section AA

1"

4 1/2"

1" Radius

Specifications
(1.) STEEL: #4 @ 9" O.C.E.W.

3/

(2.) 4,000 p.s.i. CONCRETE.


(3.) Chamfer all exposed edges 3/4".

4"

Chamfer

Nosing Detail

(4.) WEIGHT: 1,764 Lbs.


-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Savannah Type "B"


Left Top Slab for Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.26

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

Not Project North


(Back of Curb)
3' - 0"

6"

8" Deep x 5' - 0" Wide Slot

6"

4' - 0"

6"

6"

9" to 14" Deep x


2' - 6" Wide Slot

Materials

14"

Varies

Varies

9"

8"

4 1/2"

Ref: Topslab Detailed on


Section.Page 3.30.

4,000 p.s.i. CONCRETE.


WALL REINFORCING:
#4 @ 8" O.C.E.W. or equivalent WWF.

6"

BOTTOM SLAB REINFORCING


#4 @ 8" O.C.E.W.
TOP SLAB REINFORCING
#4 @ 9" O.C.E.W.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

3' x 4' Savannah Type "B" Right Curb Inlet

STATE

GA

SECTION PAGE

DATE

6.27 12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

9' - 9"
4' - 4"

5' - 5"
32 1/2"

26 1/2"

3' - 11"

4' - 5"

26 1/2"

32 1/2"

6"

Plan View

4 1/2"

USF# 1259-BP "Storm" R/C (Cast-In)

24"

Section AA
1"

4 1/2"

1" Radius

Specifications
(1.) STEEL: #4 @ 9" O.C.E.W.

3/

(2.) 4,000 p.s.i. CONCRETE.


(3.) Chamfer all exposed edges 3/4".

4"

Chamfer

Nosing Detail

(4.) WEIGHT: 1,764 Lbs.


-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Savannah Type "B"


Right Top Slab for Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.28

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures


Not Project North
(Back of Curb)

3' - 0"

6"

6"

8" Deep x 5' - 0" Wide Slot

6"

4' - 0"

6"

9" - 14" Deep x


2' - 6" Wide Slot

9" - 14" Deep x


2' - 6" Wide Slot

Materials

14"

Varies

Varies

9"

8"

4 1/2"

Ref: Topslab Detailed on


Section.Page 3.32.

4,000 p.s.i. CONCRETE.


WALL REINFORCING:
#4 @ 8" O.C.E.W. or equivalent WWF.

6"

BOTTOM SLAB REINFORCING


#4 @ 8" O.C.E.W.
TOP SLAB REINFORCING
#4 @ 9" O.C.E.W.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

3' x 4' Savannah Type "C" Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.29

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

14' - 1"
4' - 4"

5' - 5"

4' - 4"

32 1/2"

A
6"

26 1/2"

4' - 5"

3' - 11"

26 1/2"

32 1/2"

Plan View
4 1/2"

USF# 1259-BP "Storm" R/C (Cast-In)

24"

Section AA

1"

4 1/2"

1" Radius

Specifications
(1.) STEEL: #4 @ 9" O.C.E.W.

3/

(2.) 4,000 p.s.i. CONCRETE.


(3.) Chamfer all exposed edges 3/4".

4"

Chamfer

Nosing Detail

(4.) WEIGHT: 2,546 Lbs.


-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Savannah Type "C"


Top Slab for Curb Inlet

STATE

SECTION PAGE

DATE

GA

6.30

12-01-10
HEIDELBERGCEMENT Group

North

Not Project

Precast Drainage Structures

4' - 0"

6"

Varies

3"

(b.)

16"

(c.)

4 1/2"

6"

3' - 0"

6"

6"

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
#4 @ 12" O.C.E.W. or equivalent WWF.
BOTTOM SLAB REINFORCING
#4 @ 12" O.C.E.W.
TOP SLAB REINFORCING
See Top Slab Detail; Section.Page - 3.19.

6"

4"

NOTE:

(a.) Steps to be PS1-PF @ 12" C/C on North Wall.


(b.) Throat, Savannah, Type "B" Left.
(c.) Top, Savannah, Type B, Lft. w/USF1259-BP.
TITLE

3' x 4' Savannah Type "B" Left C.I. w/Throat

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.31

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

"

3' - 0"

1 /2

3' 8 1/2"

4' - 2 1/2"

6 1/2"

4' - 8"

6"

8"

8"

8"

A
4' - 10 1/2"

3' - 7"

6 1/2"

Plan View

5 1/2"

15 5/8"

16 1/2"

4"

4 1/2"

See Separate Drawing


For Precast Top Slab

Section AA

Specifications
(1.) Concrete Compressive Strength to be
4,000 psi @ 28 days.
(2.) WEIGHT: 2,800 Lbs.

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

City of Savannah
Precast Type "B" - Left Throat

STATE

SECTION PAGE

DATE

GA

6.32

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6 1/2"

3' - 0"

See Separate Drawing

8"

For Precast Top Slab

/Foot Slope

6 1/8"
5"

7"

9 1/2"

4"

12"

#4 @ Pedestal

3 x 4 W5/W6.7 wwf

15 5/8"

1/ "
4

4 1/2"

16 1/2"

4 1/2"

8"

#4 Stirrups @ 12" C/C

#4 @ 12" C/C

w/ 4 ea. - #4 Bars

Section B-B

6 1/2"

8"

3' - 0"

See Separate Drawing


For Precast Top Slab

/Foot Slope

6 1/8"

1/ "
4

3 x 4 W5/W6.7 wwf

15 5/8"

9 1/2"

5 1/2" 4"

12"

5"

4 1/2"

16 1/2"

4 1/2"

8"

#4 Stirrups @ 12" C/C

#4 @ 12" C/C

w/ 4 ea. - #4 Bars

Section C-C

Specifications
(1.) Concrete Compressive Strength to be
4,000 psi @ 28 days.
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

City of Savannah
Precast Type "B" - Left or Right Throat Details

STATE

SECTION PAGE

DATE

GA

6.33

12-01-10
HEIDELBERGCEMENT Group

North

Not Project

Precast Drainage Structures

4' - 0"

6"

4 1/2"

6"

3' - 0"

6"

6"

Varies

3"

(b.)

16"

(c.)

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
#4 @ 12" O.C.E.W. or equivalent WWF.

4"

TOP SLAB REINFORCING


See Top Slab Detail; Section.Page - 3.21.

6"

BOTTOM SLAB REINFORCING


#4 @ 12" O.C.E.W.

NOTE:

(a.) Steps to be PS1-PF @ 12" C/C on North Wall.


(b.) Throat, Savannah, Type "B" Right.
(c.) Top, Savannah, Type B, Rgt. w/USF1259-BP.
TITLE

3' x 4' Savannah Type "B" Right C.I. w/Throat

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.34

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

6 1/2"

4' - 8"

6"

8"

8"

8"

4' - 2 1/2"

3' - 0"

1
/2 "

3' - 8 1/2"

B
4' - 10 1/2"

3' - 7"

6 1/2"

Plan View

15 5/8"

5 1/2"

16 1/2"

4"

4 1/2"

See Separate Drawing


For Precast Top Slab

Section AA

Specifications
(1.) Concrete Compressive Strength to be
4,000 psi @ 28 days.
(2.) WEIGHT: 2,800 Lbs.

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) See Page 3.26 for Section B-B and Section C-C.

TITLE

City of Savannah
Precast Type "B" - Right Throat

STATE

SECTION PAGE

DATE

GA

6.35

12-01-10
HEIDELBERGCEMENT Group

North

Not Project

Precast Drainage Structures

4' - 0"

6"

4 1/2"

6"

3' - 0"

6"

6"

3"

(b.)

16"

(c.)

Varies

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
#4 @ 12" O.C.E.W. or equivalent WWF.
BOTTOM SLAB REINFORCING
#4 @ 12" O.C.E.W.
TOP SLAB REINFORCING
See Top Slab Detail; Section.Page - 3.23.

6"

4"

NOTE:

(a.) Steps to be PS1-PF @ 12" C/C on North Wall.


(b.) Throat, Savannah, Type "C".
(c.) Top, Savannah, Type C, w/USF1259-BP, R & C.
TITLE

Savannah Type "C" Curb Inlet w/Throat

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.36

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

4' - 8"

4' - 4"

4' - 4"

C
2"

3' - 0"

1
/2 "

8"

1
/2 "

8"

6"

8"

4' - 2 1/2"

3' - 8 1/2"

1/

4' - 10 1/2"

A
4' - 10 1/2"

3' - 7"
13' - 4"

Plan View

16 1/2"

4"
5 1/2"

15 5/8"

1/

2"

See Separate Drawing


For Precast Top Slab

Section AA

Specifications
(1.) Concrete Compressive Strength to be
4,000 psi @ 28 days.
(2.) WEIGHT: 4,100 Lbs.

NOTE:
-No ScaleAll dimensions subject to allowable
specification tolerances.

(1.) See Page 3.26 for Section B-B and Section C-C.

TITLE

City of Savannah
Precast Type "C" Throat

STATE

SECTION PAGE

DATE

GA

6.37

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3 x 4 W5/W6.7 wwf

#4 @ 12" C/C

2"

4"

#4 Stirrups @ 12" C/C

2 Ea. - #4 Bars

3 Spa. @ 12"

3 1/2"

3 1/2"

3' - 7"

Plan View

-No ScaleAll dimensions subject to allowable


specification tolerances.
TITLE

City of Savannah Precast Type "C" Throat


Steel Reinforcement Detail

STATE

SECTION PAGE

DATE

GA

6.38

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

3' - 0"

6"

6"

3' - 0"

6"

6"

4"

3/4" Chamfer for


all Exposed Edges.

Varies

24"

Materials
4,000 p.s.i. CONCRETE.
WALL REINFORCING:
3 x 4 W3.1/4.1 WWF - 65 KSI.
BOTTOM SLAB REINFORCING
#4 @ 6" O.C.E.W.
TOP SLAB REINFORCING
See Top Slab Detail; Section.Page - 3.33.

6"

6"

NOTE:

(a.) 1 ea. ~ Cast, USF, Rng, 1259 (Cast-In).


(b.) 1 ea. ~ Cast, USF, Cvr, BP, Plain (Cast-In).

TITLE

3' x 3' Savannah Roof Inlet

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

6.39

12-01-10
HEIDELBERGCEMENT Group

Precast Drainage Structures

4' - 0"

USF 1259-BP Plain Vented R/C

4"

4' - 0"

#4 @ 6" OCEW
Chamfer All Edges 3/4".

Specifications
(1.) Concrete Compressive Strength to be
4,000 psi @ 28 days.
(2.) All Reinforcement to be Grade 60.
(2.) Weight: 652 Lbs.
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

City of Savannah Standard D6


Roof Inlet Top Slab

STATE

SECTION PAGE

DATE

GA

6.40

12-01-10
HEIDELBERGCEMENT Group

Precast Sanitary Structures

Varies

6"

Hatch Cast in as Specified

6"
Min.

Varies

6"

4"

NOTE:
(A). Vault inside Dimensions and Steel Reinforcing as required.
-No ScaleAll dimensions subject to allowable
specification tolerances.

(B). Hatches as specified by Engineer.

TITLE

Valve Vault with Bottom Slab

STATE

SECTION PAGE

DATE

GA

7 .1

12-01-10
HEIDELBERGCEMENT Group

Precast Sanitary Structures

Varies

6"

Hatch Cast in as Specified

6"
Min.

Varies

NOTE:
(A). Vault inside Dimensions and Steel Reinforcing as required.
-No ScaleAll dimensions subject to allowable
specification tolerances.

(B). Hatches as specified by Engineer.

TITLE

Valve Vault with Open Bottom

STATE

SECTION PAGE

DATE

GA

7.2

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


1/ " hex bolt (typ.)
2

Lifting eye

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 110 Lbs.
Steel prime painted frame and cover.
Specify if galvanized is required.

24" Sq.

General Notes:

6"

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Available w/o Floor.

Weights
Designation
Depth Weight (Lbs.)
PB1818-24 .......... 24" .......... 2,175
PB1818-30 .......... 30" .......... 2,550
PB1818-36 .......... 36" .......... 2,925
PB1818-42 .......... 42" .......... 3,300
PB1818-48 .......... 48" .......... 3,675

48"
Max.

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

2' - 0" x 2' - 0" x 1' to 4'


Pull Box w/ 6" Walls (PB2424)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7 .3

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


1/ " hex bolt (typ.)
2

Lifting eye

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 162 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

24"

36"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Available w/o Floor.

Weights
Designation
Depth Weight (Lbs.)
PB2436-24 .......... 24" .......... 1,625
PB2436-30 .......... 30" .......... 1,909
PB2436-36 .......... 36" .......... 2,195
PB2436-42 .......... 42" .......... 2,479
PB2436-48 .......... 48" .......... 2,764

4"

48"
Max.

4" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

2' - 0" x 3' - 0" x 1' to 4'


Pull Box w/ 4" Walls (PB2436)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.4

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 250 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

36" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


"W" denotes without floor.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 4'; Use risers or monolithic top.

Weights
Designation
Depth Weight (Lbs.)
PB3636-24 .......... 24" .......... 2,890
PB3636-30 .......... 30" .......... 3,415
PB3636-36 .......... 36" .......... 3,940
PB3636-42 .......... 42" .......... 4,465
PB3636-48 .......... 48" .......... 4,990

6"
60"
Max.

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

3' - 0" x 3' - 0" x 1' to 4'


Pull Box w/ 6" Walls (PB3636)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7 .5

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes

Cast Iron Ring & Cover

6" Min.

36" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


"W" denotes without floor.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 4'; Use risers or monolithic top.

Weights
Designation
Depth Weight (Lbs.)
HH3636-24 .......... 24" .......... 2,890
HH3636-30 .......... 30" .......... 3,415
HH3636-36 .......... 36" .......... 3,940
HH3636-42 .......... 42" .......... 4,465
HH3636-48 .......... 48" .......... 4,990
Slabtop .............. 6" ............. 650

6"
60"
Max.

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

3' - 0" x 3' - 0" x 4' - 0"


Hand Hole w/ 6" Walls (HH3636)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7 .6

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 345 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

48" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


"W" denotes without floor.

6"
60"
Max.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top.

Weights
Designation
Depth Weight (Lbs.)
PB4848-24 .......... 24" .......... 4,575
PB4848-36 .......... 36" .......... 5,385
PB4848-42 .......... 42" .......... 6,195
PB4848-48 .......... 48" .......... 7,005
PB4848-54 .......... 54" .......... 7,875
PB4848-60 .......... 60" .......... 8,625

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 4' - 0" x 1' to 6'


Pull Box w/ 6" Walls (PB4848)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7 .7

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes

Cast Iron Ring & Cover

6" Min.

48" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


"W" denotes without floor.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top.

Weights
Designation
Depth Weight (Lbs.)
HH4848-24 .......... 24" .......... 3,935
HH4848-36 .......... 36" .......... 5,286
HH4848-42 .......... 42" .......... 5,960
HH4848-48 .......... 48" .......... 6,635
HH4848-54 .......... 54" .......... 7,310
HH4848-60 .......... 60" .......... 7,985
Slabtop .............. 6" ........... 1,350

6"
60"
Max.

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 4' - 0" x 6' - 0"


Hand Hole w/ 6" Walls (HH4848)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.8

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6" Min.

120" Max.
48"
72"
6"
6"

6" Min.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 10' - 0" x Depth Required.

Optional sump
Plastic Sump Pan
12" x 4" Deep
Duct terminators, knockouts
or blockouts provided as required.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 0" x 6' to 10'


Manhole w/ 6" Walls (MH4896)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.9

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes

Cast Iron Ring & Cover

6" Min.

60" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Hand Hole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top.

Weights

6"
72"
Max.

Designation
Depth Weight (Lbs.)
HH6060-48 .......... 48" .......... 9,300
HH6060-54 .......... 54" ......... 10,125
HH6060-60 .......... 60" ......... 10,950
Slabtop .............. 6" .......... 2,200

6" Min.
Optional sump
Plastic Sump Pan
Duct terminators, knockouts
or blockouts provided as required. 12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

5' - 0" x 5' - 0" x 6' - 0"


Hand Hole w/ 6" Walls (HH6060)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.10

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6"

96"
60"
120"

6"

6" Min.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As shown.)

Optional sump
Plastic Sump Pan
12" x 4" Deep
Duct terminators, knockouts
or blockouts provided as required.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

5' - 0" x 10' - 0" x 6' to 8'


Manhole w/ 6" Walls (MH60126)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.11

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6" Min.

120"
72"

72"
6"

6" Min.

Optional sump
Plastic Sump Pan
12" x 4" Deep
Duct terminators, knockouts
or blockouts provided as required.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As shown.)

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

6' - 0" x 6' - 0" x 6' to 10'


Manhole w/ 6" Walls (MH7272)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.12

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6"

96"
72"
96"
6"

6" Min.

Optional sump
Plastic Sump Pan
12" x 4" Deep
Duct terminators, knockouts
or blockouts provided as required.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As shown.)

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

6' - 0" x 8' - 0" x 6' to 10'


Manhole w/ 6" Walls (MH72108)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.13

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6"

96"
72"
144"
6"

6"

Optional sump
Plastic Sump Pan
12" x 4" Deep

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As shown.)

Duct terminators, knockouts


or blockouts provided as required.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

6' - 0" x 12' - 0" x 7' to 12'


Manhole w/ 6" Walls (MH72144)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.14

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

8" Min.

4' - 0"
Max.

6"

Duct terminators, knockouts


or blockouts provided as required.

8' - 0"

8' - 0"

Optional sump

6"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

4' - 0" Plastic Sump Pan


Max. 12" x 4" Deep

MIN EXCAVATION
10' - 0" x 10' - 0" x Depth Required.

8" Min.

Knockout
as req'd.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

8' - 0" x 8' - 0" x 5' to 8'


Octogonal Manhole w/ 6" Walls (MH96960)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.15

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

8" Min.

4' - 0"
Max.

6"

Duct terminators, knockouts


or blockouts provided as required.

10' - 0"

10' - 0"

Optional sump

6"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

4' - 0" Plastic Sump Pan


Max. 12" x 4" Deep

MIN EXCAVATION
12' - 0" x 12' - 0" x Depth Required.

7" Min.

Knockout
as req'd.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

10' - 0" x 10' - 0" x 5' to 8'


Octogonal Manhole w/ 6" Walls (MH1201200)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.16

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes


Bell Approved RTC

3/ "
4

6" Min.

7"

42"
60"

6"
52"

8"
Optional sump
Plastic Sump Pan
12" x 4" Deep

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.
Handhole to be placed on 6" base of gravel for
even load distribution and ease of installation.

MIN EXCAVATION
5' - 0" x 6' - 6" x Depth Required.

WEIGHTS:
Body Section 9,275 lbs.

Duct terminators, knockouts


or blockouts provided as required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Bell South Standard 4260 Handhole


(HH4260)

GA

7.17

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes


Cast Iron Ring & Cover

6"

48"

72"

60"
Max.

Duct terminators, knockouts


or blockouts provided as required.

6"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.
Handhole to be placed on 6" base of gravel for
even load distribution and ease of installation.

6"

Optional sump
Plastic Sump Pan
12" x 4" Deep

Depth > 6'; Use risers or monolithic top.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 0" x 4' - 0" Hand Hole w/6" Walls
(HH4896)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.18

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes

Cast Iron Ring & Cover

6" Min.

72" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.
Handhole to be placed on 6" base of gravel for
even load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top.

Weights
Designation
Depth Weight (Lbs.)
HH7272-48 .......... 48" ......... 11,475
HH7272-54 .......... 54" ......... 12,450
HH7272-60 .......... 60" ......... 13,425
Slabtop .............. 6" ........... 3,100

6"
72"
Max.

6" Min.
Optional sump
Plastic Sump Pan
Duct terminators, knockouts
12" x 4" Deep
or blockouts provided as required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

6' - 0" x 6' - 0" x 6' - 0"


Hand Hole w/ 6" Walls (HH7272)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.19

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Hand Holes


Cast Iron Ring & Cover

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

120"
Max.
48"

48"

4" Min.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

6" Min.

Concrete structure design for HS-20-44 loading.


Handhole to be placed on 6" base of gravel for
even load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 6' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 4' - 0" x 6' to 12'


Hand Hole w/ 6" Walls (HH4848)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.20

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6" Min.

144" Max.
48"
72"
6"
6"

6" Min.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As shown.)

Optional sump
Plastic Sump Pan
12" x 4" Deep
Duct terminators, knockouts
or blockouts provided as required.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength.

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 0" x 6' to 12'


Manhole w/ 6" Walls (MH4872)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.21

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6" Min.

96" Max.
48"
78"
5"
5"

6" Min.
Optional sump
Plastic Sump Pan
12" x 4" Deep

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Duct terminators, knockouts


or blockouts provided as required.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 6" x 6' to 8'


Manhole w/ 5" Walls (MH4878)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.22

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring & Cover

6" Min.

144"
72"
96"
6"

6" Min.

Optional sump
12" x 4" Deep
Plastic Sump Pan
Duct terminators, knockouts
or blockouts provided as required.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Manhole to be placed on 6" base of gravel for


even load distribution and ease of installation.

Depth > 6'; Use risers or monolithic top.

Material

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

6' - 0" x 8' - 0" x 5' to 12'


Manhole w/ 6" Walls (MH7296)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.23

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"
5"

39"

6"

(2) 12" x 4" Deep


Plastic Sump Pan
Bell South min. 48 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO fourteenth


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type A-Center Duct 6' x 12' x 7' Manhole


(MH72144A)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.24

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"

5"

39"

6"
(2) 12" x 4" Deep
Plastic Sump Pan
Bell South min. 48 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type A-Lateral 6' x 12' x 7' Manhole


(MH72144A)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.25

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"
5"

39"

6"
(2) 12" x 4" Deep
Plastic Sump Pan
Bell South min. 72 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type T-Center Duct 6' x 12' x 7' Manhole


(MH72144T)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.26

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"
5"

39"

6"
(2) 12" x 4" Deep
Plastic Sump Pan
Bell South min. 72 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO fourteenth


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type T-Lateral 6' x 12' x 7' Manhole


(MH72144T)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.27

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"
5"

39"

6"
(2) 12" x 4" Deep
Plastic Sump Pan
Bell South min. 72 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type J4-Center Duct 6' x 12' x 7' Manhole


(MH72144J4)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.28

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

Grade Adjustment Collar

6"
84"
72"
45"
144"
5"

39"

6"
(2) 12" x 4" Deep
Plastic Sump Pan
Bell South min. 96 Terminators
Square to Round.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 14' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

Type J4-Lateral 6' x 12' x 7' Manhole


(MH72144J4)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.29

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

6"
120"
72"
120"
6"

6"

(2) 12" x 4" Deep


Plastic Sump Pan

General Notes:

Design in accordance with ACI 318, AASHTO current

Terminators, Knockouts
or Blockouts provided
as req'd.

edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
8' - 0" x 17' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top. (As Shown.)

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

6' x 10' x 6' to 10' Manhole with 6" Walls


(MH72120)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.30

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes


Cast Iron Ring and Cover

8" Min

120"
96"
96"

6" min.

8" Min.

12" x 4" Deep


Plastic Sump Pan

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
10' - 0" x 10' - 0" x Depth Required.

Depth > 6'; Use risers or monolithic top. (As Shown.)

Terminators, Knockouts
or Blockouts provided
as req'd.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks per Bell South
Specifications.
TITLE

8' - 0" x 8' - 0" x 6' to 10' Manhole with 6" Walls
(MH9696)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.31

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring and Cover

8" Min.

84"
96"
144"

6"

7" Min.

Optional sump
Plastic Sump Pan
12" x 4" Deep

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load

Terminators, Knockouts
or Blockouts provided
as req'd.

distribution and ease of installation.

Depth > 6'; Use risers or monolithic top. (As Shown.)

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable racks as required

TITLE

8' - 0" x 12' - 0" x 4' - 6" to 7' Manhole


with 6" Walls (MH9696)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.32

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring and Cover

9" Min.

96"
120"
6"

9" Min.

192"

Optional sump
Plastic Sump Pan
12" x 4" Deep
Terminators, Knockouts
or Blockouts provided
as req'd.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
12' - 0" x 18' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable racks as required

TITLE

10' - 0" x 16' - 0" x 8' - 0" Manhole with 6" Walls
(MH120192)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.33

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Manholes

Cast Iron Ring and Cover

9" Min.

96"
120"
6"
240"

9" Min.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Terminators, Knockouts
or Blockouts provided
as req'd.

General Notes:

Design in accordance with ACI 318, AASHTO current


edition and ASTM C857 where applicable.

Designed for HS-20-44 loading.

Manhole to be placed on 6" base of gravel for even load


distribution and ease of installation.

MIN EXCAVATION
12' - 0" x 22' - 0" x Depth Required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable racks as required

TITLE

10' - 0" x 20' - 0" x 8' - 0" Manhole with 6" Walls
(MH120240)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.34

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye

1/ " hex bolt (typ.)


2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 250 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

36"

48"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


W denotes without floor.

Pull Box to be placed on 6" base of gravel for

4"
48"
Max.

even load distribution and ease of installation.

MIN EXCAVATION
5' - 0" x 6' - 0" x Depth Required.

Weights

4" Min.

Designation
Depth Weight (Lbs.)
PB3648-24 .......... 24" .......... 2,250
PB3648-30 .......... 30" .......... 2,635
PB3648-36 .......... 36" .......... 3,015
PB3648-42 .......... 42" .......... 3,400
PB3648-48 .......... 48" .......... 3,785

Duct terminators, knockouts


or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

3' - 0" x 4' - 0" x 1' to 4'


Pull Box w/4" Walls (PB3648)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.35

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 500 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

36"
60"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


W denotes without floor.

Pull Box to be placed on 6" base of gravel for

6"
60"
Max.

even load distribution and ease of installation.

MIN EXCAVATION
5' - 0" x 8' - 0" x Depth Required.

Weights
Designation
Depth Weight (Lbs.)
PB3660-36 .......... 36" .......... 5,850
PB3660-42 .......... 42" .......... 6,525
PB3660-48 .......... 48" .......... 7,200
PB3660-54 .......... 54" .......... 7,875
PB3660-60 .......... 60" .......... 8,550

6" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

3' - 0" x 5' - 0" x 1' to 5'


Pull Box w/6" Walls (PB3660)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.36

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye (typ.)
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 500 Lbs.
Steel prime painted frame and cover.
Specify if galvanized is required.
For Removable I-Beam
4" x 4" x 2" Pocket
42"

60"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


W denotes without floor.

Pull Box to be placed on 6" base of gravel for

6"
60"
Max.

even load distribution and ease of installation.

MIN EXCAVATION
5' - 6" x 8' - 0" x Depth Required.

Weight

8"

Optional sump
Plastic Sump Pan
12" x 4" Deep

Body Section 9275 lbs. (60" depth)

Duct terminators, knockouts


or blockouts provided as required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

Bell South Standard 4260 Pull Box


(PB4260)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.37

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye (typ.)
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 500 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

48"
72"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


W denotes without floor.

Pull Box to be placed on 6" base of gravel for

6"
60"
Max.

even load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 8' - 0" x Depth Required.

Weights
Designation
Depth Weight (Lbs.)
PB4872-36 .......... 36" ......... 7,575
PB4872-42 .......... 42" ......... 8,400
PB4872-48 .......... 48" ......... 9,225
PB4872-54 .......... 54" ....... 10,050
PB4872-60 .......... 60" ....... 10,875

5" Min.
Optional sump
Plastic Sump Pan
12" x 4" Deep

Duct terminators, knockouts


or blockouts provided as required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 0" x 1' to 5'


Pull Box w/6" Walls (PB4872)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.38

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes


Lifting eye (typ.)
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 500 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

48"
78"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box available with or without floor.


W denotes without floor.

Pull Box to be placed on 6" base of gravel for

5"
60"
Max.

even load distribution and ease of installation.

MIN EXCAVATION
6' - 0" x 8' - 6" x Depth Required.

Weights
Designation
Depth Weight (Lbs.)
PB4878-36 .......... 36" ......... 6,950
PB4878-42 .......... 42" ......... 7,165
PB4878-48 .......... 48" ......... 7,870
PB4878-54 .......... 54" ......... 8,575
PB4878-60 .......... 60" ......... 9,283

5" Min.
Duct terminators, knockouts
or blockouts provided as required.

Optional sump
Plastic Sump Pan
12" x 4" Deep

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 6" x 1' to 5'


Pull Box w/5" Walls (PB4878)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.39

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Pull Boxes

Lifting eye (typ.)


1/ " hex bolt (typ.)
2

Steel prime painted frame and cover.


Specify if galvanized is required.

60"

108"

12"

Beaded weld lettering


cover as specified

Frame Lid
(Specify Parkway or Traffic)

48"
96"

4' - 0"

General Notes:

6"

Design in accordance with ACI 318,


AASHTO current edition and ASTM C857
where applicable.
Concrete structure design for HS-20-44
loading.
Specify load rating for cover.
Pull Box available with or without floor.
W denotes without floor.
Pull Box to be placed on 6" base of gravel
for even load distribution and ease of
installation.
MIN EXCAVATION
6' - 0" x 10' - 0" x Depth Required.

4"

Optional sump
Plastic Sump Pan
12" x 4" Deep

Duct terminators, knockouts


or blockouts provided as required.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 0" x 4' - 0" Pull Box w/6" Walls
(PB4896)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.40

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults


1/ " hex bolt (typ.)
2

Lifting eye

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 110 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

24" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
4' - 8" x 4' - 8" x Depth Required.

Weights

4"
48"
Max.

Designation
Depth Weight (Lbs.)
UV2424-12 .......... 12" ............ 470
UV2424-16 .......... 16" ............ 625
UV2424-20 .......... 20" ............ 780
UV2424-24 .......... 24" ............ 940

Endwall knockouts or openings


as requred for pipe entry.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

2' - 0" x 2' - 0" x 1' to 4' Utility Vault


w/4" Walls (UV2424)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.41

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults


1/ " hex bolt (typ.)
2

Lifting eye (Typ.)

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 250 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

36" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
5' - 8" x 5' - 8" x Depth Required.

Weights

4"
48"
Max.

Designation
Depth Weight (Lbs.)
UV3636-24 .......... 24" ......... 1,340
UV3636-36 .......... 36" ......... 2,000
UV3636-42 .......... 42" ......... 2,340
UV3636-48 .......... 48" ......... 2,670

Endwall knockouts or openings


as requred for pipe entry.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

3' - 0" x 3' - 0" x 1' to 4' Utility Vault


w/4" Walls (UV3636)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.42

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults


1/ " hex bolt (typ.)
2

Lifting eye (Typ.)

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 345 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

48" Sq.

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
6' - 8" x 6' - 8" x Depth Required.

Weights

4"
72"
Max.

Designation
Depth Weight (Lbs.)
UV4848-24 .......... 24" ......... 1,740
UV4848-36 .......... 36" ......... 2,615
UV4848-42 .......... 42" ......... 3,050
UV4848-48 .......... 48" ......... 3,485
UV4848-54 .......... 54" ......... 3,920
UV4848-60 .......... 60" ......... 4,355

Endwall knockouts or openings


as requred for pipe entry.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 4' - 0" x 1' to 6' Utility Vault


w/4" Walls (UV4848)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.43

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults


Lifting eye (Typ.)
1/ " hex bolt (typ.)
2

Beaded weld lettering


cover as specified

Steel Cover
(Specify cover type.)
Approx. Wt. = 570 Lbs.

Steel prime painted frame and cover.


Specify if galvanized is required.

48"
78"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C857 where applicable.

Concrete structure design for HS-20-44 loading.


Specify load rating for cover.

Pull Box to be placed on 6" base of gravel for even


load distribution and ease of installation.

MIN EXCAVATION
9' - 4" x 6' - 10" x Depth Required.

Weights

72"
Max.

5"

Designation
Depth Weight (Lbs.)
UV4878-24 .......... 24" ......... 2,820
UV4878-36 .......... 36" ......... 4,230
UV4878-42 .......... 42" ......... 4,935
UV4878-48 .......... 48" ......... 5,640
UV4878-54 .......... 54" ......... 6,345
UV4878-60 .......... 60" ......... 7,050

Endwall knockouts or openings


as requred for pipe entry.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength..

STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

Pull eyes, grounding rod hole & inserts for cable rocks as req'd.
TITLE

4' - 0" x 6' - 6" x 1' to 6' Utility Vault


w/5" Walls (UV4878)

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.44

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

F
A
D

G
E
B

Size
B

Tk.
C

43"
68"
72"
96"
96"

56"
23"
72"
72"
96"

4"
10"
10"
10"
10"

Open
D
E

30"
56"
48"
48"
54"

13.5"
11"
16"
16"
24"

Edge Dist.
F
G

6.5"
6"
12"
24"
21"

Wt.
(lbs.)

6"
6"
8"
8"
8"

690
815
3,785
5,265
6,790

Other Sizes Available Upon Request.

General Notes:

Pad to be placed on 6" base of gravel for even load


distribution and ease of installation.

Inserts to be plastic or stainless steel as specified.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: Grade 60 conforming to ASTM A-706 as specified
on reinforcing drawings.
TITLE

Equipment Pad
Type 1

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.45

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

F
A
D

G
E

B
E
G
C

Size
B

Tk.
C

86"

80"

6"

Open
D
E

74"

24"

Edge Dist.
F
G

6"

Wt.
(lbs.)

8"

1,710

Other Sizes Available Upon Request.

General Notes:

Pad to be placed on 6" base of gravel for even load


distribution and ease of installation.

Inserts to be plastic or stainless steel as specified.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: Grade 60 conforming to ASTM A-706 as specified
on reinforcing drawings.
TITLE

Equipment Pad
Type 2

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.46

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

F
D

D
F

G
E

Size
B

Tk.
C

86"

56"

6"

Open
D
E

30"

13.5"

Edge Dist.
F
G

6.5"

Wt.
(lbs.)

6"

2,085

Other Sizes Available Upon Request.

General Notes:

Pad to be placed on 6" base of gravel for even load


distribution and ease of installation.

Inserts to be plastic or stainless steel as specified.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: Grade 60 conforming to ASTM A-706 as specified
on reinforcing drawings.
TITLE

Equipment Pad
Type 3

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.47

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

Top Surface Flat


For Equipment
Mounting

3/ " Dia. Thru Hole


4
18" Below Top Surface

36"

56"

18"

34"
40"
6"

6"

15"

12"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C-857 where applicable.

Pit to be placed on 6" base of gravel for even


load distribution and ease of installation.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

TITLE

3' - 0" x 4' - 8" x 40" Mounting Pit


w/6" Walls

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.48

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

Top Surface Flat


For Equipment
Mounting

3/ " Dia. Thru Hole


4

18" Below Top Surface

36"

48"

18"

34"
40"
6"

6"

15"

12"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C-857 where applicable.

Pit to be placed on 6" base of gravel for even


load distribution and ease of installation.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

TITLE

3' - 0" x 4' - 0" x 40" Mounting Pit


w/6" Walls

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.49

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

Top Surface Flat


For Equipment
Mounting

3/ " Dia. Thru Hole


4
18" Below Top Surface

60"

60"

18"

34"
40"
6"

6"

15"

12"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C-857 where applicable.

Pit to be placed on 6" base of gravel for even


load distribution and ease of installation.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

TITLE

5' - 0" x 5' - 0" x 40" Mounting Pit


w/6" Walls

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.50

12-01-10
HEIDELBERGCEMENT Group

Precast Electrical Vaults

Top Surface Flat


For Equipment
Mounting

3/ " Dia. Thru Hole


4

18" Below Top Surface

72"

72"

18"

34"
40"
6"

6"

15"

12"

General Notes:

Design in accordance with ACI 318, AASHTO


current edition and ASTM C-857 where applicable.

Pit to be placed on 6" base of gravel for even


load distribution and ease of installation.

Materials

CONCRETE: 5,500 PSI, 28 day compressive strength.


STEEL: 60,000 psi yield strength ASTM A-615 Reinforcing Steel.

TITLE

6' - 0" x 6' - 0" x 40" Mounting Pit


w/6" Walls

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

7.51

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Use
Precast box sections are recommended for installations where circular or elliptical
concrete pipe cannot provide adequate flow capacity, and as a superior substitute for
cast-in-place box culverts, long span metal arches, short bridges, and multi-barrel
circular culverts or drains.
Crown-Span Bridge Units are recommended for installations where precast box
sections cannot carry the required flow capacity, uninterrupted opening spans are
necessary, natural stream bottoms are desired and installation time is important.

Sizes
Precast box sections are normally available in spans of 4 feet through 12 feet, with a
variety of rises. Crown-Span Bridge Units are normally available in spans of 10 feet
through 28 feet, with rises up to 10 feet. Please refer to the details that follow for
specific dimensions.
Application
Precast box sections and Crown-Span Bridge Units can be used for the following:
highway culverts
railroad culverts
highway bridges
short span highway bridges
storm drains
livestock, pedestrian or golf cart undercrossings
utility tunnels
underground stormwater retention structures
groundwater recharge systems
to replace existing open channels or ditches, and enable land to be used productively
jacked or tunneled installations.
Joints
Precast box sections are produced with tongue and groove joints for packing with
mastic joint compound, preformed mastic or butyl gaskets, or mortar.
Crown-Span adjacent sections are butted with a similar mastic compound.
Appurtenances
Precast headwalls and wingwalls are available for most sizes.
Linings / Coatings
A variety of linings and coatings is available where project conditions dictate their use.
(Information continued on next page.)

www.hansonpipeandprecast.com
TITLE

Information - Precast Box Culverts & Crown Span

STATE

SECTION PAGE

DATE

GA

8.1

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Uses Applicable Specifications
The following specifications apply to precast concrete box sections.
ASTM C1433 - Precast Reinforced Concrete Monolithic Box Sections for Culverts,
Storm Drains, and Sewers
ASTM C1577 - Precast Reinforced Concrete Monolithic Box Sections for Culverts,
Storm Drains, and Sewers according to AASHTO LRFD.
When specifying precast box sections, the following information is needed:
Governing design specification (eg. ASTM, AASHTO, AREA, etc.)
Design live load (eg. AASHTO HS-20, AREA Cooper E80, etc.)
Design fill range (eg. 0'-2', 2'-5', 5'-10', etc.).

TITLE

Information - Precast Box Culverts & Crown Span

STATE

GA

SECTION PAGE

8.2

DATE

12-01-10
HEIDELBERGCEMENT Group

Span

10

12

FT

Tt
Tb
Tw

8
8
8

9
9
9/8*

8
7
6

8
7
7

8
8
8

8
8
8

9
9
9

10
10
10

12
12
12

Inches

x 2'
x 3'
x 4'
x 5'
x 6'
x 7'
x 8'
x 9'
x 10'
x 11'
x 12'

-0.76

-1.0*
1.12

0.77
0.84
0.92
1.00
1.07
1.15
1.22
1.30
1.38
1.45
1.53

-1.01
1.10
1.18
1.27
1.36
1.45
1.54
1.63
1.72
1.81

-1.22
1.33
1.43
1.53
1.63
1.73
1.83
1.94
2.04
2.14

-1.33
1.43
1.53
1.63
1.73
1.83
1.94
2.04
2.14
2.24

--1.75
1.86
1.98
2.09
2.21
2.32
2.43
2.55
2.66

--2.10
2.23
2.36
2.48
2.61
2.74
2.86
2.99
3.12

--2.90
3.05
3.20
3.36
3.51
3.66
3.81
3.97
4.12

Tons per Unit Foot

Weight for
Each Rise

Box
Geometry 2

Precast Box Culverts & Crown-Span

Groove

Outside

Tongue

As Req'd.
(Typ. 72")

Tt , Tb , or Tw

As Req'd.

Creep Typ.

Inside

Top

Joint Detail

Rise

Tt

Scale : 1" = 5'

H = Tw
Typ.

Notes:
(1.) Joint to be sealed with state approved sealant in accordance
with manufacturer's instructions.

12" 4"

Tb

(2.) Slab and wall thicknesses may vary for some designs:
dimensions subject to permissible variation of ASTM C1433,
AASHTO M259/273 and AASHTO M198 Type B.

Span

Section A-A

(3.) Lift points as required.

Tw
Typ.

(4.) Pull Holes: 2 1/2" . To be filtered or filled in field by others.


(5.) 4' x 4' RCB H = 6"; 3' x 3' RCB H = 3".
TITLE

Dimensions, Weights & Joint Details - Box Culvert

STATE

SECTION PAGE

DATE

GA

8 .3

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Feet
Span
x
Rise

Sq. Ft.

CFS

Area

C1

3x3
4x3
4x4
4x5
4x6
4x7
4x8
4x9
4 x 10
4 x 11
4 x 12
5x2
5x3
5x4
5x5
5x6
5x7
5x8
5x9
5 x 10
5 x 11
5 x 12
6x3
6x4
6x5
6x6
6x7
6x8
6x9
6 x 10
6 x 11
6 x 12

8.9
11.7
15.7
19.7
23.7
27.7
31.7
35.7
39.7
43.7
47.7
9.5
14.5
19.5
24.5
29.5
34.5
39.5
44.5
49.5
54.5
59.5
17.3
23.3
29.3
35.3
41.3
47.3
53.3
59.3
65.3
71.3

678
1,237
1,839
2,472
3,126
3,795
4,473
5,160
5,853
6,550
7,251
889
1,633
2,459
3,338
4,253
5,193
6,153
7,128
8,113
9,108
10,110
2,034
3,096
4,236
5,432
6,668
7,935
9,225
10,534
11,859
13,196

Inches
Eqv.

36
45
53
59
64
69
73
78
81
85
88
40
50
59
66
72
78
83
88
92
96
100
55
64
72
79
85
91
96
101
106
110

Eqv
2

28
35
41
45
50
53
57
60
63
65
68
31
39
45
51
56
60
64
67
71
74
77
42
49
56
61
66
70
74
78
82
85

Feet
Span
x
Rise

Sq. Ft.

CFS

Area

C1

Eqv.

Eqv
2

2,436
3,741
5,155
6,647
8,197
9,792
11,422
13,080
14,762
16,462
2,867
4,422
6,117

59
69
78
85
92
99
104
110
115
120
62
73
83

45
53
60
66
71
76
81
85
89
92
48
56
64

7,915
9,792
11,730
13,717
15,744
17,803
19,889
5,080
7,065
9,181
11,399
13,697
16,059
18,474
20,933
23,429

91
99
105
112
118
123
129
77
87
96
104
112
119
125
131
137

70
76
81
86
91
95
99
59
67
74
80
85
92
96
101
105

7x3
20.1
7x4
27.1
7x5
34.1
7x6
41.1
7x7
48.1
7x8
55.1
7x9
62.7
7 x 10 69.1
7 x 11 76.1
7 x 12 83.1
8x3
23.1
8x4
31.1
8x5
39.1
8x6
47.1
8x7
55.1
8x8
63.1
8x9
71.1
8 x 10 79.1
8 x 11 87.1
8 x 12 95.1
9x4
34.9
9x5
43.9
9x6
52.9
9x7
61.9
9x8
70.9
9x9
79.9
9 x 10 88.9
9 x 11 97.9
9 x 12 106.9

Feet
Span
x
Rise

Inches

10 x 4
10 x 5
10 x 6
10 x 7
10 x 8
10 x 9
10 x 10
10 x 11
10 x 12
11 x 4
11 x 5
11 x 6
11 x 7
11 x 8
11 x 9
11 x 10
11 x 11
11 x 12
12 x 4
12 x 5
12 x 6
12 x 7
12 x 8
12 x 9
12 x 10
12 x 11
12 x 12

Sq. Ft.

CFS

Inches

Area

C1

Eqv.

Eqv
2

38.6
48.6
58.6
68.6
78.6
88.6
98.6
108.6
118.6
42.3
53.3
64.3
75.3
86.3
97.3
108.3
119.3
130.3
46.0
58.0
70.0
82.0
94.0
106.0
118.0
130.0
142.0

5,738
8,018
10,459
13,028
15,697
18,449
21,268
24,144
27,068
6,393
8,972
11,746
14,673
17,725
20,878
24,115
27,423
30,791
7,046
9,927
13,037
16,331
19,772
23,337
27,004
30,757
34,585

81
91
101
110
118
125
132
138
144
84
95
106
115
123
131
138
145
152
87
99
110
119
128
137
144
151
158

62
71
78
85
91
96
102
107
111
65
74
81
88
95
101
107
112
117
67
76
85
92
99
105
111
117
122

Manning's Formula:
Q = C1 x Slope -

1
2

Rise

(CFS)
H

Where C1 is a constant, dependent only


on the geometry of the pipe or box section.
Full flow values of C1 are calculated using
a roughness factor of 0.013. Capacity of
culverts may be governed by inlet conditions.
For further information, see the ACPA
concrete pipe design manual.

Span

8' x 4' Box Section Shown

For accuracy, equivalent round (Eqv. )


and equivalent double round (Eqv. 2)
are not rounded to standard pipe sizes.

TITLE

Full Flow Hydraulic Data - Box Culverts

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

8 .4

12-01-10
HEIDELBERGCEMENT Group

10

12

14

16

18

20

22

24

26

28

FT

Tt

12

12

12

12

12

12

12

12

12

12

Tw

12

12

12

12

12

12

12

12

12

12

x 4'

1.63

1.78

1.94

2.09

2.25

2.40

2.56

2.71

2.87

3.02

x 5'

1.78

1.94

2.09

2.25

2.40

2.56

2.71

2.87

3.02

3.18

x 6'

1.94

2.09

2.25

2.40

2.56

2.71

2.87

3.02

3.18

3.33

x 7'

2.09

2.25

2.40

2.56

2.71

2.87

3.02

3.18

3.33

3.49

x 8'

2.25

2.40

2.56

2.71

2.87

3.02

3.18

3.33

3.49

3.64

x 9'

2.40

2.56

2.71

2.87

3.02

3.18

3.33

3.49

3.64

3.80

x 10'

2.56

2.71

2.87

3.02

3.18

3.33

3.49

3.64

3.80

3.95

Inches

Span

Tons per Unit Foot

Weight for 1
Each Rise

Box
Geometry

Precast Box Culverts & Crown-Span

1/ " = 0.04'
2
Creep Typ.

Outside

96"

Tt or Tw

48"

Inside

Top

Joint Detail
Tt

Not to scale

Rise

H = Tw
Typ.
4

Notes:
(1.) Joint to be sealed with state approved sealant in accordance
with manufacturer's instructions.

12" 4"

(2.) Other span and wall thicknesses are available


(3.) Lift points as required.

Span

(4.) Optional Pull Holes: 2 1/2" . To be filled with grout


or filler material in field by others.

Section A-A

(5.) For larger spans, only shorter lengths may be available


due to production and handling constraints.

TITLE

Dimensions, Weights & Details - Crown-Span

Tw
Typ.

-No ScaleAll dimensions subject to allowable


specification tolerances.
STATE

GA

SECTION PAGE

8 .5

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

Notes:
(1.) Typical footing by contractor.
(2.) Footing and floor to be poured separately.
(3.) If required, construction joints shall be
provided at not less than 12 ft.
(4.) Footing and floor must be poured on firm,
undisturbed earth or rock as directed by
the engineer.
TITLE

Crown-Span Footing and Floor - Single Line

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

8.6

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

Notes:
(1.) Typical footing by contractor.
(2.) Footing and floor to be poured separately.
(3.) If required, construction joints shall be
provided at not less than 12 ft.
(4.) Footing and floor must be poured on firm,
undisturbed earth or rock as directed by
the engineer.
TITLE

Crown-Span Footing and Floor - Multiple Lines

-No ScaleAll dimensions subject to allowable


specification tolerances.
STATE

GA

SECTION PAGE

8 .7

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


ls7
Zmt

ld1

As6

As7

As5

As2

Avt

Tt

Nlt

svt

Nlw

Reinforcement Shown
is Schematic Only

Avw

svw

Rise (ft.)
Encapsulated Dimensions
Indicate Typical
H

As4

As1

Nlb
As3

svb

Tb
Zmb

As8

ld1

Avb
ls8
Tw

Span (ft.)

Precast Box Section


(Lift holes not shown.)

Label Description Key:


Tt Tb Tw H s1, 2 & 3 -

Thickness of top slab (in.)


Thickness of bottom slab (in.)
Thickness of wall (in.)
Haunch height and width (in.)
Maximum circumferential wire spacing for As1, As2 & As3 (in.) not shown.

As 1
As 2
As 3
As 4
As 7
As 8

Wall - outside ................... circumferential reinforcement steel (sq. in. / Lf)


Top slab - inside .............. circumferential reinforcement steel (sq. in. / Lf)
Bottom slab - inside ......... circumferential reinforcement steel (sq. in. / Lf)
Wall - inside ..................... circumferential reinforcement steel (sq. in. / Lf)
Top slab - outside ............ circumferential reinforcement steel (sq. in. / Lf)
Bottom slab - outside ....... circumferential reinforcement steel (sq. in. / Lf)

As 5
As 6
Avt
Nl t
sv t

Top slab - inside longitudinal distribution reinforcement steel (sq. in. / ft. of width)
Top slab - outside longitudinal distribution reinforcement steel (sq. in. / ft. of width)
Shear reinforcement steel in the top slab (sq. in. / Lf / line)
Number of lines of shear reinforcement in the top slab (in.)
Spacing between the lines of shear reinforcement in the top slab (in.)

Avb - Shear reinforcement steel in the bottom slab (sq. in. / Lf / line)
Nlb - Number of lines of shear reinforcement in the bottom slab
svb - Spacing between the lines of shear reinforcement in the bottom slab (in.)
Avw - Shear reinforcement steel in the side wall (sq. in. / Lf / line)
Nlw - Number of lines of shear reinforcement in the side wall
svw - Spacing between the lines of shear reinforcement in the top side wall (in.)
Zmt - Required extension of As1 in the top slab (in.)
Zmb - Required extension of As1 in the bottom slab (in.)
ls7 - Splice length for As7 per AASHTO 8.32 (in.)
ls8 - Splice length for As8 per AASHTO 8.32 (in.)
ld1 - Development length for As1 per AASHTO 8.30 (in.)
CCORto - Top outside concrete cover over reinforcement steel (in.)
CCORti - Top inside concrete cover over reinforcement steel (in.)
CCOR - All other concrete cover over reinforcement steel (in.)
TITLE

Precast Box Reinforcement Section Details

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

8 .8

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


12 & 13
3

20

v x d + H (Typ)
v x d (Typ)

4
Xdc
(Typ)

Rise

14 & 15
21

22
C

Symetric

16 & 17

7
8

9 10

11

xdc

23

Mu
(Vu x v x d)

18 & 19

= 3.0

Span

End View
Design Specifications:
Circumferential Reinforcement:
AASHTO 17 . 7 . 4 . 8 .............. Minimum Reinforcement ........................................... (002 Min.)
AASHTO 17 . 4 . 6 . 4 . 1 ......... Reinforcement for Flexural Strength ......................... (Flexure)
AASHTO 8 . 20 . 1 ................... Shrinkage and Temperature Reinforcement ............. (Thermal)
AASHTO 17 . 7 . 4 . 7 .............. Maximum Stress for Crack Control ........................... (Fs Max.)
AASHTO 17 . 4 . 6 . 4 . 4 ......... Crack Width Control .................................................. (Crack)
AASHTO 8 . 16 . 8 . 3 .............. Fatigue Stress Limits ................................................. (Stl. Strs.)
AASHTO 17 . 4 . 6 . 4 . 3 . 2 .... Limited by Concrete Compression ............................ (Compress)
Longitudinal Distribution Reinforcement:
AASHTO 3 . 24 . 10 ................. Distribution Reinforcement
Shear Strength: (Method 1 - Design Sections 12 thru 19)
AASHTO 8 . 16 . 6 . 2 . 1 ......... Shear in Beams and One-Way Slabs and Footings
AASHTO 8 . 16 . 6 . 7 . 1 ......... Special Provisions for Slabs of Box Culverts
Shear Strength: (Method 2 - Design Sections 12 thru 23)
AASHTO 17 . 4 . 6 . 4 . 5 ......... Shear Strength
Shear Reinforcement:
AASHTO 17 . 4 . 6 . 4 . 6 . 2 .... Shear Stirrups
Development of Reinforcement:
AASHTO 8 . 30 ........................ Development of Welded Wire Fabric in Tension
AASHTO 8 . 32 ........................ Splices of Reinforcement

Reinforcement Unit Consolidation:


As 1
As 2
As 3
As 4
As 7
As 8

Meets the requirements of design sections: 2 - 10 Neg. : 12 - 19


Meets the requirements of design sections: ......... 1 Pos. : 20.
Meets the requirements of design sections: ....... 11 Pos. : 23.
Meets the requirements of design sections: ......... 6 Pos.
Meets the requirements of design sections: ......... 1 Neg. : 12 & 13.
Meets the requirements of design sections: ....... 11 Neg. : 18 & 19.

Av t Meets the requirements of design sections: 12, 13 & 20.


Av b Meets the requirements of design sections: 18, 19 & 23.
Av w Meets the requirements of design sections: 14 - 17, 21 & 22.
-No ScaleAll dimensions subject to allowable
specification tolerances.

Reinforcement Units may be combined provided


that the requirements of each unit are met.
TITLE

Precast Box Design Technical Details and Notes

STATE

GA

SECTION PAGE

8 .9

DATE

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


ls7
Zmt

ld1

As6

As7

As5

As2

Avt

Tt

Nlt

svt

Nlw

Rise (ft.)

Reinforcement Shown
is Schematic Only

Avw

svw

Encapsulated Dimensions
Indicate Typical

As1

As4

Span (ft.)

Tw

(Lift holes not shown.)

Crown Span Section


Label Description Key:
Tt Tw H s1, 2 & 3 As 1
As 2
As 4
As 7

Thickness of top slab (in.)


Thickness of wall (in.)
Haunch height and width (in.)
Maximum circumferential wire spacing for As1, As2 & As3 (in.) not shown.
Wall - outside ................... circumferential reinforcement steel (sq. in. / Lf)
Top slab - inside .............. circumferential reinforcement steel (sq. in. / Lf))
Wall - inside ..................... circumferential reinforcement steel (sq. in. / Lf)
Top slab - outside ............ circumferential reinforcement steel (sq. in. / Lf)

As 5 - Top slab - inside longitudinal distribution reinforcement steel (sq. in. / ft. of width)
As 6 - Top slab - outside longitudinal distribution reinforcement steel (sq. in. / ft. of width)
Avt - Shear reinforcement steel in the top slab (sq. in. / Lf / line)
Nlt - Number of lines of shear reinforcement in the top slab (in.)
svt - Spacing between the lines of shear reinforcement in the top slab (in.)
Avw - Shear reinforcement steel in the side wall (sq. in. / Lf / line)
Nlw - Number of lines of shear reinforcement in the side wall
svw - Spacing between the lines of shear reinforcement in the top side wall (in.)
Zmt - Required extension of As1 in the top slab (in.)
Zmb - Required extension of As1 in the bottom slab (in.)
ls7 - Splice length for As7 per AASHTO 8.32 (in.)
ld1 - Development length for As1 per AASHTO 8.30 (in.)
CCORto - Top outside concrete cover over reinforcement steel (in.)
CCORti - Top inside concrete cover over reinforcement steel (in.)
CCOR - All other concrete cover over reinforcement steel (in.)

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Crown-Span Reinforcement Section Details

GA

8.10

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


12 & 13
3

20

v x d + H (Typ)
v x d (Typ)

4
Xdc
(Typ)

Rise

14 & 15
21

22
C

Symetric

16 & 17

Span

xdc

Mu
(Vu x v x d)

= 3.0

End View

Design Specifications:
Circumferential Reinforcement:
AASHTO 17 . 7 . 4 . 8 .............. Minimum Reinforcement ........................................... (002 Min.)
AASHTO 17 . 4 . 6 . 4 . 1 ......... Reinforcement for Flexural Strength ......................... (Flexure)
AASHTO 8 . 20 . 1 ................... Shrinkage and Temperature Reinforcement ............. (Thermal)
AASHTO 17 . 7 . 4 . 7 .............. Maximum Stress for Crack Control ........................... (Fs Max.)
AASHTO 17 . 4 . 6 . 4 . 4 ......... Crack Width Control .................................................. (Crack)
AASHTO 8 . 16 . 8 . 3 .............. Fatigue Stress Limits ................................................. (Stl. Strs.)
AASHTO 17 . 4 . 6 . 4 . 3 . 2 .... Limited by Concrete Compression ............................ (Compress)
Longitudinal Distribution Reinforcement:
AASHTO 3 . 24 . 10 ................. Distribution Reinforcement
Shear Strength: (Method 1 - Design Sections 12 thru 19)
AASHTO 8 . 16 . 6 . 2 . 1 ......... Shear in Beams and One-Way Slabs and Footings
AASHTO 8 . 16 . 6 . 7 . 1 ......... Special Provisions for Slabs of Box Culverts
Shear Strength: (Method 2 - Design Sections 12 thru 23)
AASHTO 17 . 4 . 6 . 4 . 5 ......... Shear Strength
Shear Reinforcement:
AASHTO 17 . 4 . 6 . 4 . 6 . 2 .... Shear Stirrups
Development of Reinforcement:
AASHTO 8 . 30 ........................ Development of Welded Wire Fabric in Tension
AASHTO 8 . 32 ........................ Splices of Reinforcement

Reinforcement Unit Consolidation:


As 1
As 2
As 4
As 7

Meets the requirements of design sections: 2 - 10 Neg. : 12 - 19


Meets the requirements of design sections: ......... 1 Pos. : 20.
Meets the requirements of design sections: ......... 6 Pos.
Meets the requirements of design sections: ......... 1 Neg. : 12 & 13.

Av t Meets the requirements of design sections: 12, 13 & 20.


Av w Meets the requirements of design sections: 14 - 17, 21 & 22.
Reinforcement Units may be combined provided
that the requirements of each unit are met.
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Crown-Span Design Technical Details and Notes

STATE

SECTION PAGE

DATE

GA

8.11

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Design Criteria: AASHTO Section17
Materials and Purchasing Criteria: ASTM C1433 or as appropriate.
Installation Criteria: AASHTO Division 11, section 27 and state modifications thereto.
Concrete Cover Over Reinforcement (CCOR): AASHTO Divisi
0' to 2' fill:
CCORto, Top-Outside = 2.0 in.
CCORti, Top-Intside = 1.0 in.
CCOR,
All other
= 1.0 in.

2' Fill.
CCORto,
CCORti,
CCOR,

Top-Outside = 1.0 in.


Top-Inside = 1.0 in.
All Other
= 1.0 in.

Material Properties:
Design Concrete Strength .................................. fc ...................... 5 ksi ....................................... AASHTO 17 . 7 . 2 . 1
Reinforcement Yield Stress ............................... fy .................... 85 ksi ....................................... AASHTO 17 . 7 . 2 . 2
Concrete Density ............................................... rhoc .......... 150 pcf ....................................... AASHTO 3 . 3 . 6

Load Factors:
Dead Load Factor for Moment and Shear ......... DLFmv ...........
Dead Load Factor for Thrust .............................. DLFn ..............
Live Load Factor for Moment and Shear ........... LLFmv ............
Live Load Factor for Thrust ................................ LLFn ...............

1.3 ....................................... AASHTO 3 . 22 . 1


1.0 ....................................... N/A
2.17 ........ (Betol = 1.67) ...... AASHTO 3 . 22 . 1
1.0 ....................................... N/A

Capacity Reduction Factors:


Shear ................................................................. phiv .............. 0.90 ....................................... AASHTO 17 . 7 . 4 . 6
Flexure ............................................................... phif ............... 1.00 ....................................... AASHTO 17 . 7 . 4 . 6

Soil Properties:
Soil Density ........................................................ rhoE ......... 120 pcf ....................................... AASHTO
Minimum Laterial Soil Pressure Coefficient ....... CoMin .......... 0.250 ...................................... AASHTO
Maximum Laterial Soil Pressure Coefficient ...... CoMax ......... 0.500 ...................................... AASHTO
Soil Structure Interaction Factor ........................ SIF .............. 1.0 .......................................... AASHTO
(Alter required height of fill for SIF not equal to 1.0, if needed.)
(CoMin - Used to determine negative moments in slabs and positive moments in walls.)
(CoMax - Used to determine positive moments in slabs and negative moments in walls.)

6.2.1
6 . 2 . 1 & 3 . 22
6.2.1
17 . 4 . 4 . 2

Live Load Data:


Live Load ........................ HS-20 and Alt-1 (Alternate Interstate Fig. 3.7.7A)
AASHTO 3 . 7. 6
Tire Contact Area, Lwh = 8 in. x BetoL: 2' : Wwh = 20 in., Wwh = 20 in., <2' : Wwh = 4 + FT. AASHTO 3 . 30 & 3 . 24 . 3 . 2
Live Load Distribution ........................................ 1.75 x H ........................................................ AASHTO 6 . 4 . 2 & 3 . 24 . 3 . 2

Allowable Reinforcement Spacing:


Circumferential wire spacing to be not less than 2 in., nor more than 4 in.
Circumferential wire spacing of As1 to be not more than s1.
Circumferential wire spacing of As2 to be not more than s2.
Circumferential wire spacing of As3 to be not more than s3.
Longitudinal wire spacing to be not less than 2 in., nor more than 8 in. using welded wire fabric.
Longitudinal distribution reinforcement may be welded wire fabric and / or deformed bars.

Depth to Reinforcement:
d = h - CCOR - dw / 2
dw = SQR(As / NLAY x s l / b) x [NLAY + .4 x (NLAY - 1)]
d - Depth to reinforcement.
dw - Diameter of reinforcement wire.
CCOR - Concrete cover over reinforcement at tension face section.
h - Section thickness: Includes haunch, H, for sections at face of supports. (Except in calculation of minimum reinforcement).
Two layers of reinforcement, NLAY, presumed for depth calculation except for crack control design where 1 layer is more conservative.
(Multiple layers increase the number of wires.) Smooth welded wire fabric presumed for crack control.

Design Designation:

Example - 1006A215

Box Span (ft.)


Crown-Span
(If Applicable)

Design Specification:

A - AASHTO
Fill Range:

CS

10

06 A 2 15

Box Rise (ft.)

Live Load:

1 - HS 20 - 44
2 - AASHTO Alternate Interstate
7 - AASHTO HS - 27
8 - A. R. E. A. Cooper E80

02
0' - 2'
05
2' - 5'
10
5' - 10'
15
10' - 15'
Remainder in 5' increments

Expanded: 10' x 6' AASHTO / ASTM alternate interstate for 10' to 15' fill.
TITLE

AASHTO / ASTM Precast Section Design Parameters

STATE

SECTION PAGE

DATE

GA

8.12

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

36
"
M

H
ee
l

Weephole

St
e
To m
e

Lh

Plan View
Ts

Key:
K:
L:
M:
Ts:
Th:
Ttoe:
Lh:
Lt:

12"

Lt

Elevation - Front

Ttoe

Th

Depth

30"
Scour

Invert

Upper Stem Height, 12" Increments (Typ.)


Lower Stem Height.
Stem Lenght, 12" Increments (Typ.)
Stem Thickness, 8" (Typ.)
Heel Thickness, 8" (Typ.)
Toe Thickness, 18" (Typ.)
Heel Length, 6" Increments (Typ.), 12" Min.
Toe Length, 14" for K less than 10 feet,
28" for K of 10 feet or more.

Notes:
(1.) All joining surfaces to be neatly sealed with state approved sealant.

M
Up To

Number of
Weepholes

12'
18'
24'
30'
36'

1
2
3
4
5

(2.) All components designed to be independently stable in overturning, sliding


and bearing. Components should not be externally restrained by
mechanical connectors. Such connection could lead to stress
concentrations from minor settlement or thermal expansion.

@ 72" c-c

(3.) Reinforcement to be ASTM 615 #4 bars @ 12" E.W.E.F., unless noted.


Material Properties: fy = 60 ksi, fc = 4 ksi.
Concrete Cover Over Reinforcement, CCOR = 1.5" Minimum.
(4.) Wing walls may be produced in 8' mimimum sections as shipping
limitations dictate. Weepholes to be adjusted to provide 1' clear
to section joints, if needed.
-No ScaleAll dimensions subject to allowable
specification tolerances.

(5.) 3/4" Chamfer on all exposed 90 corners.

TITLE

STATE

SECTION PAGE

DATE

Precast Box and Crown-Span Wing Wall (BWW)

GA

8.13

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

Multi-Cell RCB End Section Detail


#4 @ 12" oc
3 - #4
@ 2" oc

4" Nominal Joint


Offset
Between Lines
Seal Joint
Note 1

H
ee
l

Tw

8
St "
em

3/ " Insert
4

14
To "
e

3/ " Anchor Bolt


4

Bull Nose
4 - #4 Bars
1" Clear Min Typ.

Wing Wall
(Right)

Plan View

Tb
Grade Beam

30" Scour Depth

Rise

Tt

12"
Parapet

Box End Section

Front Elevation
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

End Wall (ES) and Wing Wall (BWW) Connection Details

STATE

SECTION PAGE

DATE

GA

8.14

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Bull Nose / Parapet Detail
Bull Nose

12" Min.

Grout 4" x 4" Block


Out After Fastening

12" Parapet

Tt

2" Clear (Typ.)

Box Crown

4" x 4"
Chamfer
(Inlet Only)

Beveled
Haunch Inlet
HH

3 - #4 Bars
1 1/ " Clear
4
Min (Typ.)

3" Preformed Opening


4 - #4 Bar

Tb

Box Invert

HH

Beveled
Haunch Inlet

1/ " Grout
2

Seal
Joint
Note 1

Grade
Beam

Scour
Depth
30"

Leveling
Pad (By Others)

6" x 6"
Preformed
Opening

Elevation Section (@ C)
Notes:
(1.) All joining surfaces to be neatly sealed with state approved sealant.
(2.) All components designed to be independently stable in overturning, sliding
and bearing. Components should not be externally restrained by
mechanical connectors. Such connection could lead to stress
concentrations from minor settlement or thermal expansion.
(3.) Reinforcement to be ASTM 615 #4 bars @ 12" E.W.E.F., unless noted.
Material Properties: fy = 60 ksi, fc = 4 ksi.
Concrete Cover Over Reinforcement, CCOR = 1.5" Minimum.
(4.) Grade Beam must be installed before box end section and is required by design to
retain fill and pressure below box sections. Minimum grade beam lengh to be
equal to the overall width of the finished End Section. Conctactor to provide and
place #6 bars in preformed openings and grout in the field.
TITLE

End Wall (ES) and Wing Wall (BWW) Connection Details

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

8.15

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span


Overall Centerline Length
(May be Increased to Facilitate
End Section Dimensions.)

Face of Precast Concrete End


Section Will Maintain Variation
of No More than 2".

Maintain Average
Laid Length. 6.04'

Box End Section Lengths to be


in Accordance with State
Specifications and Guidelines.

Offset
2 (Typ.)

1
Headwall Skew A
(25 R Shown)

12" + C - I - P Headwall
(By Others) with 2"
Precast End Section
Embedded

3" to 6" Typ


(4 " Nominal)
10" Exposed
Reinforcement
for Ties to
Headwall

Span

4
Tw (Typ.)

Plan

LAY

FLOW
(Typ.)

Tt
5

Rise

Tb

Elevation Section A-A


Notes:
(1.) Headwall skew measured from perpendicular to headwall, To: Box C.
(2.) Offset based on 4" nominal spacing between lines.
(3.) Joining at sections to be in accordance with project plans and state specifications.
(4.) Other end treatment (Such as no exposed reinforcement) also available . . .
Request if desired.
(5.) Cast-in-place head, wing and transition wall (By others) to be in accordance
with project plans and state specifications.
(6.) Installation criteria to be in accordance with AASHTO Division II, Section 27
and state specifications.
(7.) Haunches not shown. Detail to scale for 5' x 3' box.
TITLE

Precast Layout with Cast-In-Place Headwalls

STATE

SECTION PAGE

DATE

GA

8.16

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

Pipe Openings

Angle
(Run C to Opening C:
60 R shown, 90
Tee)

Center

Center
R

(Typ.)

FLOW

LAY

(Typ.)

FLOW

LAY

Manhole Openings

Run C

Grove to Opening C:
(38" Typ.)

Run C

Opening
Span

ing
en n
p
O pa
S

Grove to Opening C:
(@ C Wall, 38" Typ.)

Opening
Rise

Plan

Plan
Run Inside Wall to Opening C:
[@(Opening Rise) / 2 Typ.]

hown)

Slope (+5% S

Opening
Rise

Run Inv. to Opening C:


(@ C Wall)

Section B-B

Section A-A

Notes:
(1.) 90 Tee openings will be provided for tie-in pipe at angles of 80 to 100
and at slopes up to 17.5%.
(2.) For round openings, Span = Diam. = Rise.
(3.) For slopes > 1% , project plans should state where invert of tie-in pipe
is defined: Run C or inside face of wall.
(4.) When job conditions dictate that an opening be located across a joint
in the run, two semi-circular openings will be provided.
(5.) Haunches not shown when hidden. Details to scale for 6' x 5' box
x 24" MH opening RT, and 6' x 5' box x 24" - 60 R opening.
TITLE

Precast Openings in Precast Rectangular Sections

STATE

SECTION PAGE

DATE

GA

8.17

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

Typical Riser

See Note #4

Min 3'-0" and Up


(1'-0" Increments)

See Note #5

See Note #6

See Note #5

See Note #5

See Note #5

Typical Spans
Min 3'-0" and Up
(1'-0" Increments)

See Note #8
and Joint Detail
See Note #6

al

pic

y
"T

'-6

o7

t
Up
See Note #7

ns

tio

gth

c
Se

en

L
ay

See Note #8

Joint Detail

Materials & Features:


(1.) Precast box culvert design specifications shall be in accordance with ACI-318 "Building Requirements for Structural Concrete",
AASHTO Standard Specifications for Highway Bridges", ASTM C1433 "Precast Reinforced Concrete Monolithic Box Sections for Culverts,
Storm Drains. and Sewers, or ASTM C1577 "Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and Sewers.
(2.) Concrete compressive strength 5,000 psi minimum unless otherwise specified.
(3.) Steel reinforcing designed to conform to the requirements outlined in note #1 and shall utilize grade 60 re-bars conforming to the
requirements of ASTM A185 or WWF conforming to the requirements of ASTM A185 or both.
(4.) Typical haunch detail shall be 8" x 8". Larger haunches are available for culverts of longer spans, deeper fills or heavy live load requirements.
(5.) Wall, roof, and floor dimensions shall be determined by job conditions. Typical configurations as well as steel requirements are
detailed in ASTM C1433 and C1577 as per note #1.
(6.) Penetrations in roof slab and walls can be provided dependent on job conditions. Additional steel will be required at all penetrations.
(7.) Weep holes available per job requirements and are typically placed one per culvert section at each exterior wall.
(8.) Tongue and groove shall be sized in proportion to culvert cross section. Joints shall be sealed by 1" x 1" close cell neoprene
sponge gasket material which is factory applied to the "Bell" or "Groove" end of the culvert section.
(9 .) See special details for end treatments, curves, and additional options available.

TITLE

STATE

SECTION PAGE

DATE

Precast Box Culvert


Single Cell

GA

8.18

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

See Note #2

See Note #1

See Note #3

See Note #4

See Note #4

General Notes:
(1.) Dowel bar splicers may be cast in to facilitate tie in to cast in place headwalls, wingwalls
and footings.
(2.) Rebar may be extended to facilitate tie ins in lieu of note #1.
(3.) Precast end wall designs are available to create containment structures. Call Hanson's
Enginering Department for further details.
(4.) Embedded wall plates may be provided to accommodate special job conditions.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Precast Box Culvert


End Treatment Detail

GA

8.19

12-01-10
HEIDELBERGCEMENT Group

Precast Box Culverts & Crown-Span

e
Se #1
te
No

Single

n
ctio

e
rS
rrie pical
a
B
Ty
th
ng 7'-6"
e
y L p to
La
U
in.

"M

6
1'-

Se

te
No

#2

n
tio
ec
S
r
l
rrie
ca
Ba Typi
h
t
6"
ng
Le to 7'y
La
Up

"
'-6

Twin

n.

Mi

General Notes:
(1.) Standard skewed angle may be limited due to section length as related to span of culvert.
Special length end sections can be produced to increase skewed angle.
(2.) Special skew configured can be achieved in single and multiple cell culverts by
incorporating a precast headwall into the end design, Call Hanson's Engineering
Department for further details.

-No ScaleAll dimensions subject to allowable


specification tolerances.

TITLE

STATE

SECTION PAGE

DATE

Precast Box Culvert


Skewed Ends

GA

8.20

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Premier Notes
The following notes shall apply unless noted otherwise on the plans or specifications. In the case of
conflict with the plans or specifications, the more restrictive requirements shall apply.

Reference Specifications:
HIGHWAY LIVE LOADING, AASHTO LRFD Bridge Design Specifications, Section 36 Standard design capacity is HS20.
RAIL LIVE LOAD AND GENERAL DESIGN AREMA MANUAL FOR RAILWAY ENGINEERING.
Standard design capacity is Cooper E80.

Concrete
1. Aggregate conforms to ASTM C33.
2. Portland cement conforms to ASTM C150.
3. Fly ash conforms to ASTM C618.
4. Minimum compressive strength (at 28 days) = 7,000 p.s.i. unless greater strength is required by project specifications.

Reinforcing Steel
1. All bar reinforcing steel conforms to ASTM A706.
2. Welded wire fabric conforms to ASTM A497, 65 KSI.
3. Concrete cover of reinforcing steel conforms to AREMA Standard.

Installation
1. Prior to dismantling the track assembly, stake out the alignment for the new crossing with offsets located
every four track feet.
2. Remove existing track assembly including all rail, hardware, ties, and ballast. Remove subgrade below
the ballast to the hardpan.
3. Inspect for proper drainage and deficient subgrade. Remove any deficient subgrade material. The
overall excavation should be at least 10 feet wide to accommodate the new construction.
4. Prepare the new subgrade with clean granular material or a controlled low strength material (CLSM or
flowable fill). The top 6 inches of the subgrade is formed and screeded level. Granular material is
placed in four inch lifts to finished top of subgrade. This material is compacted to 95% proctor density.
Screed top of subgrade to level. The subgrade is compacted again which will typically create a 3/4 inch
gap to the top of subgrade. Compact 3/8 inch minus crushed stone (screenings) to top of subgrade.
The subgrade is now complete for the granular subgrade option. If using CLSM, place the CLSM to the top
of the leveling form. Screed the CLSM and allow to cure. For this option, the subgrade is complete.
5. Establish the centerline of the existing track. Mark the centerline at the bottom of the premier module, For
a curved alignment, use offsets from centerline at four foot increments. Reference curve data chart for
proper module spacing.
6. When placing modules for tangent track use 1/4 inch shims between modules. When placing modules on
a curved alignment, refer to the curved data chart. Gaps are required between modules to prevent spalling.
Make note at this time if beveled ends are used in the crossing.
7. Remove both center panels together and stack outside the immediate working area. Clean threaded inserts
of fallen debris and protect the inserts to prevent debris from filling the insert during installation. Pull rail into
position by pulling the rail from the middle of the existing track and through the middle of the modules. This
ensures that a mishandled rail does not chip the exposed portion of the module.
(Notes continued on next page.)

TITLE

Premier Modular Railroad Crossing


General Notes

STATE

GA

SECTION PAGE

9.1

DATE

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Premier Notes (Continued)


Installation

(Continued)

8. After the rail is in position, lift it high enough to install the rubber boot. Unroll the boot and position the boot
under the rail. Unfold the boot. Apply the rail boot continuously from one end of the rail to the other.
Applying the boot from more than one location will create a bubble between the boot and the rail. Make
sure the high side edge of the rubber boot is toward the field side of the rail.
9. Apply lubrication (Module rail slick) to the rail seat of the module.
10. Place the rail snug into the rail seat. Place track jacks end-to-end and jack the rail into the rail seat. Use
two sets of track jacks at 4 to 8 foot intervals and leapfrogging the jacks as you install the center panels.
On extreme degree curves, leapfrog the track jacks in 4 foot intervals.
11. Install the center panels simultaneously and align the holes for the anchor bolts.
12. Install the anchor bolts by hand first, and then tighten them to 125 lbs. per foot maximum.
OVER TIGHTEN.

DO NOT

13. At the ends of the crossing, cut the rail boot flush and install two rail anchors per rail at each end of the
module.
14. Inform the contractor placing the asphalt that roller equipment will damage the Premier Modules.

TITLE

Premier Modular Railroad Crossing


General Notes

STATE

SECTION PAGE

DATE

GA

9.2

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Premier Unit

Roadway Surface

Leveling Gravel or
Stone Dust 3/8" or Less

Roadway Subgrade

New Granular
Material Compacted
Exsisting Hard Pan

Compacted or
Undisturbed Native Soil

Granular Material

Premier Unit

Roadway Surface
Roadway Subgrade

CLSM or
Flowable Fill

New Granular
Material Compacted

Exsisting Hard Pan

Compacted or
Undisturbed Native Soil

CLSM or Flowable Fill

TITLE

STATE

SECTION PAGE

DATE

Premier Modular Railroad Crossing


Typical Section

GA

9.3

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Center Panel Anchor Bolt


Typical (2) Each Panel
2 Ton Ring Clutch Lifting Anchor
Typical (1) Each Panel
Center Panel x 4' - 0"

Divergence (Gap)
4' - 0" O.D.

8' - 0" O.D.

4' - 0"
Recessed Diamond Pattern
Typical (4) Places
Base Panel x 4' - 0"

4' - 0" Symmetrical Units

Notes:
(1.) Premier units may be laid referring to the "Curve Data

Chart" for Divergence (Gap).


(2.) Tapered sections may be used to reduce divergence.
(3.) Taper shortens one side of 4' - 0" section by 1 inch.
TITLE

Premier Modular Railroad Crossing


Curved Alingments (Diverged)

STATE

SECTION PAGE

DATE

GA

9 .4

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Center Panel Anchor Bolt


Typical (2) Each Panel
2 Ton Ring Clutch Lifting Anchor
Typical (1) Each Panel
Divergence (Gap)

Center Panel x 4' - 0"

4' - 0" O.D.

8' - 0" O.D.

3' - 11"
Recessed Diamond Pattern
Typical (4) Places
Base Panel x 4' - 0"

4' - 0" Tapered Units

Notes:
(1.) Premier units may be laid referring to the "Curve Data

Chart" for Divergence (Gap).


(2.) Tapered sections may be used to reduce divergence.
(3.) Taper shortens one side of 4' - 0" section by 1 inch.
TITLE

Premier Modular Railroad Crossing


Curved Alingments (Tapered)

STATE

SECTION PAGE

DATE

GA

9.5

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossing - Curve Data Chart


Symmetrical Module
Curve
Curve Radius
(degrees)
(ft.)
1
2
3
4
5
6
6
7

5729.7
2864.9
1910.1
1432.7
1146.3
955.4
881.9
819.0

Low Side Gap


(in)
0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

1/
1/
1/
1/
1/
1/

7
8
8
9

764.5
716.8
674.7
637.3

0.250
0.250
0.250
0.250

1/

9
10
10
11

603.8
537.7
546.4
521.7

0.250
0.250
0.250
0.250

1/

11
12
12
13

499.1
478.3
459.3
441.7

0.250
0.250
-

1/

13
14
14
15

425.4
410.3
396.2
383.1

1/
1/
1/
1/
1/
1/
1/

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

48" Tapered to 47" Module

High Side Gap


(in)
0.327
0.395
0.462
0.530

5/

0.835
0.869
0.903
0.937

16
3/
8
7/
16
1/
2
9/
16
9/
16
5/
8
11/
16
11/
16
3/
4
3/
4
13/
16
13/
16
7/
8
7/
8
15/
16

0.971
1.005
-

1
1
-

0.564
0.597
0.631
0.665
0.699
0.733
0.767
0.801

Low Side Gap


(in)

High Side Gap


(in)

0.859
0.792

7/
8
13/
16

0.250
0.250

1/
4
1/
4

3/

0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

0.724
0.690
0.657
0.624

11/
5/
5/

0.591
0.568
0.525
0.492

9/

0.459
0.426
0.393
0.360

7/

0.327
0.294
0.261
0.250

3/

9/

3/

0.250
0.250
0.250
0.250

20
21
22
23

287.9
274.4
262.0
250.8

0.250
0.250
0.250
0.250

1/

24
25
26
27

240.5
231.0
222.3
214.2

0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

0.250
0.250
0.250
0.250

1/

32
33
34
35

181.4
176.0
171.0
166.3

TITLE

Premier Modular Railroad Crossing


Curve Data Chart

1/

16

359.3
338.3
319.6
302.9

16

16
17
18
19

206.7
199.7
193.2
187.1

16

1/

28
29
30
31

16

3/

5/

16

1/

5/

16

16

1/

7/

1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

STATE

SECTION PAGE

DATE

GA

9 .6

12-01-10

0.327
0.386
0.453
0.519
0.586
0.653
0.719
0.786

1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/
1/

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

4
5/
16
5/
8
7/
16
1/
2
9/
16
5/
8
11/
16
3/
4
7/
8
15/
16

0.852
0.919
0.985
1.051

1
1 1/16

1.118
1.184
1.250
1.317

1 1/8
1 3/16
1 1/4
1 5/16

1.382
1.448
1.514
1.580

1 3/8
1 1/2
1 5/8
1 3/4

HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings


Rail

Rail Boot

Rail with Standard Boot

Standard Flangeway Filler


(Optional for Transit Applications)

Rail

Rail Boot

Rail with Boot & Flangeway Filler


Walkway Flangeway Filler
(Optional for Transit Applications in Walkway
Area, Provides an ADA Approved Crossing)

Rail

Rail Boot

Rail with Boot & Walkway Filler

TITLE

Premier Modular Railroad Crossing


Boot & Optional Fillers

STATE

SECTION PAGE

DATE

GA

9 .7

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

2 Ton Ring Clutch Lifting Anchor


Typical (1) Place
Center Panel x 4' - 0"

Base Panel x 4' - 0"

Recessed Diamond Pattern


Typical (4) Places

Center Panel Anchor Bolt


Typical (2) Places

4' - 0" O.D.


8' - 0" O.D.

4' - 0" O.D.


Rail and Rail Boot
Not Shown for Clarity

2 Ton Ring Clutch Lifting Anchor


Typical (2) Places

6"

3' - 6"

Ref.

2 Ton Ring Clutch Lifting Anchor


Typical (2) Places
6" Ref.
Varies
45

1 1/2" Lifting Hole


Typical (2) Places

Base Panel x 4' - 0"


4' - 0" O.D.

Optional Beveled Edge Detail

TITLE

Premier Modular Railroad Crossing


4' - 0" Premier Unit (Isometric View)

STATE

SECTION PAGE

DATE

GA

9.8

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings


8' - 0" O.D.
Center Panel x 4' - 0"

Base Panel x 4' - 0"

2 Ton Ring Clutch Lifting


Anchor Typical (1) Each
4' - 0" O.D.

4' - 0" O.D.

Rail (Boot Not


Shown for Clarity)

Plan View

3/ " Anchor Bolt


4
Typical (2) Each Panel

Base Panel x 4' - 0"


1' - 7 3/4"

Rail (Boot Not


Shown for Clarity)

1' - 7 3/ "
4

56 1/ " (4' - 8 1/ ") Track Gauge


2
2

3/ " Anchor Bolt


4
Typical (2) Each Panel

A
6"

1/ "
2

Base Panel x 4' - 0"


B

Center Panel x 4' - 0"

Section A-A
Panel Geometry:

A
(in.)

B
(in.)

Base Wt.
(Lbs.)

Center Wt. (ea.)


(Lbs.)

100 RB Pound Rail

5 3/4

2' - 4 5/8

3,450

525

100 RE/105 Dudly Rail

2' - 4 5/8

3,500

550

112/115 Pound Rail

6 13/16

2' - 4 3/4

3,600

600

132/136 Pound Rail

7 5/16

2' - 5

3,700

650

TITLE

Premier Modular Railroad Crossing


4' - 0" Premier Unit (Plan View)

STATE

GA

SECTION PAGE

9.9

DATE

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

2 Ton Ring Clutch Lifting Anchor


Typical (2) Places

Base Panel x 8' - 0"

Center Panel x 8' - 0"


Recessed Diamond Thread
Pattern Typ. (4) Places

Center Panel Anchor Bolt


Typical (2) Places

8' - 0" O.D.


8' - 0" O.D.

1 1/2" Lifting Hole


Typical (2) Places

Rail and Rail Boot


Not Shown for Clarity

2 Ton Ring Clutch Lifting Anchor


Typical (4) Places

6"

7' - 6"

Ref.
2 Ton Ring Clutch Lifting Anchor
Typical (4) Places
6" Ref.
Varies
45

Base Panel x 8' - 0"


8' - 0" O.D.

Optional Beveled Edge Detail

TITLE

Premier Modular Railroad Crossing


8' - 0" Premier Unit (Isometric View)

STATE

SECTION PAGE

DATE

GA

9.10

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings


8' - 0" O.D.
Base Panel x 8' - 0"

Center Panel x 8' - 0"

3/ " Anchor Bolt


4

Typical (2) Each Panel

8' - 0" O.D.


2 Ton Ring Clutch Lifting
Anchor Typical (2) Each

Plan View
Rail (Boot Not
Shown for Clarity)
1' - 7 3/4"

Rail (Boot Not


Shown for Clarity)

1' - 7 3/4"

56 1/2" (4' - 8 1/2") Track Gauge

3/ " Anchor Bolt


4

Typical (2) Each Panel


A
6"

1/ "
2

Base Panel x 8' - 0"


B

Center Panel x 8' - 0"

Section A-A
Panel Geometry:

A
(in.)

B
(in.)

Base Wt.
(Lbs.)

Center Wt. (ea.)


(Lbs.)

100 RB Pound Rail

5 3/

2' - 4 5/8

6,900

1,050

100 RE/105 Dudly Rail

2' - 4 5/8

7,000

1,100

2' - 4 3/4

7,200

1,200

2' - 5

7,400

1,300

112/115 Pound Rail

6 13/

132/136 Pound Rail

7 5/

16

16

TITLE

Premier Modular Railroad Crossing


8' - 0" Premier Unit (Plan View)

STATE

SECTION PAGE

DATE

GA

9.11

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Base Panel x 4' - 0"

Plastic Filler Panel


Typical (2) Places

3/ "
4

Recessed Diamond Pattern


Typical (4) Places

Anchor Bolt
Typical (3) Each Panel

4' - 0" O.D.


8' - 0" O.D.
4' - 0" O.D.
Rail and Rail Boot
Not Shown for Clarity

2 Ton Ring Clutch Lifting Anchor


Typical (2) Places

6"
Ref.

7' - 6"
2 Ton Ring Clutch Lifting Anchor
Typical (4) Places

6" Ref.
45

1 1/2" Lifting Hole


Typical (2) Places

Base Panel x 4' - 0"


4' - 0" O.D.

Optional Beveled Edge Detail

TITLE

Premier Modular Railroad Crossing


4' - 0" Premier Plus Unit (Isometric View)

STATE

SECTION PAGE

DATE

GA

9.12

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

8' - 0" O.D.

Base Panel x 4' - 0"

Plastic Filler Panel


Typical (2) Places

4' - 0" O.D.

Rail (Boot Not


Shown for Clarity)

4' - 0" O.D.

3/ " Anchor Bolt


4
Typical (2) Each Panel

Plan View
Rail (Boot Not
Shown for Clarity)

1' - 7 3/4"

1' - 7 3/4"

56 1/2" (4' - 8 1/2") Track Gauge

3/ "
4

Anchor Bolt
Typical (3) Each Panel

A
13"

Section A-A

Rail Clip Typical (2) Each Rail

Rail Clip Pocket


Typical (2) Each Panel

Center Panel Geometry:

Weight

112/115 Pound Rail

6 13/16"

4,900 lbs.

132/136 Pound Rail

7 5/16"

4,900 lbs.

TITLE

Premier Modular Railroad Crossing


4' - 0" Premier Plus Unit (Plan View)

STATE

SECTION PAGE

DATE

GA

9.13

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

Plastic Filler Panel


Typical (2) Places

Base Panel x 8' - 0"

3/ "
4

Anchor Bolt
Typical (6) Each Panel

Recessed Diamond Pattern


Typical (3) Places

8' - 0" O.D.

8' - 0" O.D.

Rail and Rail Boot


Not Shown for Clarity

1 1/ " Lifting Hole


2
Typical (2) Places

2 Ton Ring Clutch Lifting


Anchor Typical (4) Places

6"

7' - 6"

Ref.

2 Ton Ring Clutch Lifting Anchor


Typical (4) Places
6" Ref.
45

Base Panel x 4' - 0"


8' - 0" O.D.

Optional Beveled Edge Detail

TITLE

Premier Modular Railroad Crossing


8' - 0" Premier Plus Unit (Iso. View)

STATE

GA

SECTION PAGE

9.14

DATE

12-01-10
HEIDELBERGCEMENT Group

Premier Modular Railroad Crossings

8' - 0" O.D.


Base Panel x 8' - 0"

Plastic Filler Panel


Typical (2) Places
8' - 0" O.D.

Rail (Boot Not


Shown for Clarity)

3/ "
4

Anchor Bolt
Typical (6) Each Panel

Plan View
1' - 7 3/4"

Rail (Boot Not


Shown for Clarity)

1' - 7 3/4"

56 1/2" (4' - 8 1/2") Track Gauge

3/ "
4

Anchor Bolt
Typical (6) Each Panel

A
13"

Section A-A
Rail Clip Typical (4) Each Rail

Rail Clip Pocket


Typical 4) Each Panel

Center Panel Geometry:

112/115 Pound Rail

6 13/16"

9,800 lbs.

132/136 Pound Rail

7 5/16"

9,800 lbs.

TITLE

STATE

SECTION PAGE

DATE

Premier Modular Railroad Crossing


8' - 0" Premier Plus Unit (Plan View)

GA

9.15

12-01-10
HEIDELBERGCEMENT Group

Design Data

American
Concrete Pipe
Association
Technical Series
Loads and Supporting Strengths
Hydraulics of Sewers
Hydraulics of Culverts
Installations
Miscellaneous

Published by
American Concrete Pipe Association 222 W. Las Colinas Blvd., Suite 641 Irving, TX 75039 (972) 506-7216 FAX (972) 506-7682

1996 ACPA

DD-Title (7/98) Printed in U.S.A.


Technical data herein are considered reliable, but no guarantee is made or liability assumed.

Design Data
Table of Contents
Date of Issue: March 3, 1997
Design
Data

Issue
Date

Current
Print Date

Title

Loads and Supporting Strengths


1
6
7
13
15
16
17
22
23
25
29
31
32
38
40

10/92
05/89
10/92
10/92
02/84
06/80
05/87
03/71
07/71
08/74
06/85
05/89
07/87
07/80
09/95

(R)
(R)
(R)
(R)

10/92
05/89
10/92
10/92
06/90
07/91
03/97
06/89
05/89
05/89
07/91
05/89
03/97
06/89
10/96

Highway Live Loads on Circular Concrete Pipe


Concrete Pipe Selection: (Embankment)
Concrete Pipe Selection: (Trench)
Jacking Concrete Pipe
Aircraft Loads
Railroad Loads
Loads & Supporting Strengths of HE & Arch Pipe
Surcharge Loads
Transition Width
3-Edge Bearing Strengths C14 & Clay Pipe
Multiple Pipe Installation: (Trench Condition)
Highway Live Loads on Concrete Arch Pipe
Highway Live Loads on Concrete Elliptical Pipe
Bedding Factors - Trench Installations
Standard Installation & Bedding Factors

05/89
10/92
03/97
03/97
05/89
05/89
06/88

Friction Factors for Corrugated Metal Pipe


Hydraulic Capacity of Sewers
Equivalent Flow Capacity of Sewers
Mannings n Values History of Research
Partial Flow Conditions Circular Concrete Pipe
Partial Flow Conditions Arch Concrete Pipe
Partial Flow Conditions Elliptical Concrete Pipe

(R)

05/89
10/92
05/89
06/90
05/89
10/92
05/87
01/89
04/91
12/90
12/90
05/89
05/87

Hydraulics Performance Curves


Hydraulics of Culverts: 12 - 21 Diameter Pipe
Hydraulics of Culverts: 24 - 48 Diameter Pipe
Hydraulics of Culverts: 54 - 90 Diameter Pipe
Hydraulics of Culverts: 96 - 144 Diameter Pipe
Hydraulics of Culverts: HE Concrete & Metal Arch
Hydraulics of Culverts: HE Concrete & Plate Arch
Hydraulics of Culverts: Concrete & Metal Arch
Hydraulics Capacity of Precast Concrete Boxes
Hydraulics of Culverts: Concrete Boxes 3' - 6'
Hydraulics of Culverts: Concrete Boxes 7' - 10'
Precast Concrete Box Sect Partial Flow Condition
Hydraulics of Culverts: Concrete Boxes 11' - 12'

10/80 (R)

12/88

Curved Alignment

09/90
10/92
11/87
11/96

Precast Concrete Manholes


Flotation of Circular Concrete Pipe
Low Pressure Air Testing of Sewers
Manhole Flotation

(R)
(R)

(R)
(R)

Hydraulics of Sewers
2
4
5
14
35
36
37

03/68
10/92
07/69
12/88 (R)
04/80
06/80
07/80

Hydraulics of Culverts
3
8
9
10
11
18
19
20
26
27
28
33
34

03/68
10/92
01/68
06/69
07/69
10/92
03/70
10/80
12/86
12/86
12/86
04/78
05/87

(R)

(R)
(R)
(R)
(R)
(R)

Installation
21

Miscellaneous
12
30
39
41

07/69
10/92 (R)
12/86
11/96
(R) Revised

Design Aids

Glossary - Terms Applicable to Precast Drainage Structures


Hole:

The opening left in the wall of a structure for future installation of a pipe. This
opening is always larger than the pipe O.D. See table for standard hole sizes.
Also known as knock out or window.

Brick & Casting


Adjustment:

The combined height of the casting (cover or grate) and rows of brick at the top
of a structure. Also can be throat (inlet top section) height on structures such
as D.O.T. P5 & P6 inlets.

Key Way:

The groove section of a tongue & groove joint between two parts of a structure.

Sump:

The part of a structure between the lowest pipe invert and the floor of the
structure. Also the height of this part of the structure, that is, the distance
between floor and lowest pipe invert in a structure.

Hole Raise:

Distance from floor to invert of the opening (hole) left for a pipe. Thus an 18"
dia. CMP pipe, at invert elevation 3.0, with floor elevation of 0.0 and hole dia.
of 24" has a hole raise of:
3.0 - 0.0 = 3.0' = 36"; 36" - [(24" - 18")] 2] = 33" = hole raise.

Wall Height:

The actual wall height from floor to top of concrete wall. Thus a 48" dia. manhole, RIM elev. of 7.3, floor elev. 0.0 has wall height of:
7.3 - 0.0 - (1.3' brick & casting allow.) = 6.0' = 72" = wall height.

Weep Hole:

An opening of diameter as dictated by the controlling authority, left in the floor of


drainage structures to permit draining of the sump area.

TITLE

Glossary - Terms Applicable to Precast


Drainage Structures

STATE

SECTION PAGE

DATE

GA

11.1

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Design Red Lights (Project Check List)


1.

When specifying floor and invert elevations of a structure, check for sufficient wall height to take
the required holes. Thus one must subtract brick & casting allowance, top slab thickness, and
hole raise, if applicable.

2.

Look out for too much pipe into too small a structure. There may be very little support for the
top section when all the blank outs are removed . This is particularly critical when transporting
the structure and when CMP or HDPE is used.

3.

Try to put pipes into flat wall structures at as near 90 degrees to the wall as possible. Shallow
angles require large elliptical holes and weaken the wall.

4.

Try to maintain at least 2' of cover over your pipes. Less than this may put you into the throat
area, cause conflicts with castings, or cost your client more for high strength pipe. (Note that
these are only some of the problems.)

5.

Specify pipe material on your drawing. Hole sizes differ for the same pipe in different materials.

6.

Use standard structures wherever possible. They are far more economical.

7.

Where possible, use locally manufactured castings. They do not have high transportation costs
and long delivery times.

TITLE

Design Red Lights


(Project Check List)

STATE

SECTION PAGE

DATE

GA

11.2

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Standard Hole Diameters


Notes:

(1) A dash ( - ) in the table signifies that the pipe is not manufactured or else not readily
available in a particular material.
(2) Values given in the table are those that would normally be used in our plant.
However, the blank out diameter can be varied as required by a given situation.

Pipe Size

Pipe Types

(Nominal I.D.)

D.I.P.

Clay

P.V.C.

R.C.P.

C.M.P.

4"
6"
8"

7"
12"
12"

7"
12"
12"

7"
12"
12"

12"
12"

10"
12"
14"

16"
16"
20"

16"
16"
-

16"
16"
-

21"
-

16"
18"
-

15"
16"
18"

20"
24"

20"
24"

24"
30"

21"
24"

20"
21"
24"

24"
28"

26"
28"

36"

28"
30"

30"
36"
42"

36"
42"
-

42"
48"
60"

36"
42"
48"

48"
54"
60"

66"
72"
78"

54"
60"
66"

66"
72"
78"

84"
92"
96"

72"
78"
84"

84"
90"
96"

108"
-

92"
108"

TITLE

Standard Hole Diameters

STATE

SECTION PAGE

DATE

GA

11.3

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Instructions & Examples for


Pipe Half Angle Table
(Used with circular structures - see
"Half Angle Diagram" for illustration)

Example No. 1:
To find if a given structure will accomodate two pipes on approximately the
same level, whose size and centerline included angle is specified.

Given:

48" Dia manhole, 15" dia. CMP pipe, 24" dia. CMP pipe, 76 degree
included angle between pipe centerlines.

Procedure:

(1.) Turn to "Standard Hole Diameter Table" and find: 15" CMP
hole is 21" dia., and 24" CMP hole is 30" dia.
(2.) Turn to "Pipe Half Angle Table" and find:
(a.) Structure dia. on bottom row. (48")
(b.) Hole dia. of 30" at right side of table.
(c.) Read up and left to intersection finding half angle of 38.68
degrees.
(d.) Repeat procedure for 48" dia. structure & 21" dia. hole,
finding half angle of 25.94 degrees.
(e.) In bottom row below structure dia. find separation angle of
4.77 degrees.
(f.) Add angle found in steps - (c.), (d.) & (e.) giving result of
69.39 degrees.

Result:

69.39 degrees is the normal minimum angle between these pipes in


this structure. Since this angle is less than the 76 degrees specified;
the structure will readily accommodate the pipes in question.

(See next page for example no. 2)

TITLE

Instructions & Examples for


Pipe Half Angle Table

STATE

SECTION PAGE

DATE

GA

11.4

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Instructions & Examples for


Pipe Half Angle Table (cont.)
(Used with circular structures - see
"Half Angle Diagram" for illustration)

Example No. 2:
Find the minimum structure for the pipes of Example 1 on the previous page.

Given:

Round Structure desired for reasons of economy: Find minimum diameter


structure for 15" dia. CMP pipe, 24" dia. CMP pipe; 76 degree included
angle between pipe centerlines.

Procedure:

(1.) Hole Diameters are once again 21" & 30".


(2.) Try 42" dia. structure in "Pipe Half Angle Table".
(3.) Find half angles of:
45.58 deg. for 30" hole, 30.00 deg. for 21" hole, and
5.46 deg. for 42" dia. structure sepration angle.
(4.) Total angle is 81.04 deg., which is too large, however, pipe separation
angle of 5.46 deg. can be reduced to 0 deg., and the holes butted
together at the inside wall. This is not recommended practice, but is a
design option, thus the total included angle is 75.58 deg. This is less
than the 76 deg. specified, and the 42" round will just accommodate
the pipes in question.

Note:

Structure sizes can also be reduced by decreasing hole diameters. However, the
designer should be aware such procedures increase construction difficulties, may
violate local standards, and should be avoided if at all possible.

TITLE

Instructions & Examples for


Pipe Half Angle Table (cont.)

STATE

SECTION PAGE

DATE

GA

11.5

12-01-10
HEIDELBERGCEMENT Group

Design Aids

30" Hole

24" CMP

48

"D

ia

CL

A
21" Hole

15"
MP

CL

NOTE:

A = Half angle for 21" dia. hole in a 48" dia. structure.


B = Separation angle for a 48" dia. structure.
C = Half angle for 30" dia. hole in a 48" dia. structure.
D = Min. angle between pipe CL's.
(Where hole separation is required.)
-No ScaleAll dimensions subject to allowable
specification tolerances.
TITLE

Pipe Half Angle Diagram

STATE

SECTION PAGE

DATE

GA

11.6

12-01-10
HEIDELBERGCEMENT Group

Design Aids

90.00

96"

69.64

90"

90.00

61.04

84"

68.21

54.34

78"

90.00

59.00

48.59

72"

66.44

51.79

43.43

66"

90.00

56.44

45.58

38.68

60"

64.16

48.59

40.01

34.23

54"

90.00

53.13

41.81

34.85

30.00

48"

90.00

61.04

44.43

35.69

30.00

25.94

42"

59.00

48.59

36.87

30.00

25.38

22.02

36"

45.58

38.68

30.00

24.62

20.92

18.21

30"

41.81

35.69

27.82

22.89

19.47

16.96

28"

34.85

30.00

23.58

19.47

16.60

14.48

24"

30.00

25.94

20.49

16.96

14.48

12.64

21"

25.38

22.02

17.46

14.48

12.37

10.81

18"

22.39

19.47

15.47

12.84

10.98

9.59

16"

19.47

16.96

13.49

11.21

9.59

8.39

14"

16.60

14.48

11.54

9.59

8.21

7.18

12"

13.77

12.02

9.59

7.98

6.84

5.98

10"

42"
5.46

48"
4.77

60"
3.82

72"
3.18

84"
2.73

96"
2.39

Hole Diameters
(Inches)

Half Angle
(Degrees)

Structure Diameter
(Inches)
Separation Angle
(Degrees)

TITLE

Pipe Half Angle Table

STATE

SECTION PAGE

DATE

GA

11.7

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Maximum Pipe Angle Tables


Use with Square or Rectangular Structures
Instructions / Examples
Tables I and II on the following pages give the maximum angle at which a hole of
given diameter may enter the wall of a square or rectangular structure without cutting
into the corner area of the box. In the following discussion, refer to the "Pipe Angle
Diagram, Flat Wall Structures", and Tables I & II.
Table I gives angle values for situations where the pipe and hole centerline pass
through the center of the structure. The designer must exercise care in the use of
this table since it is restricted to those structures for which it was developed. See the
notes at the bottom of the "Pipe Angle Diagram" Sheet for a listing of these structures. The table values cover most structures commonly supplied by our firm.
To find the angle for a structure not covered in the table; use the formula for diameter
given at the top of the "Pipe Angle Diagram" sheet.
Example No. 1:

Ref: Table #1 on page 4.10

Given:

It is desired to put an 18" CMP pipe through the wide side of a


"C" (24" x 36") box at an angle of 15 degrees with the box centerline
and with the pipe centerline passing through the center of the
structure. Can this be done without cutting into the box corner?

Procedure:

(1.) Turn to "Standard Hole Diameter Table" and find: 18" CMP
hole is 24" dia.
(2.) Wall thickness for a "C" box is 8", so inside wall dimension over
wall thickness is 36" / 8".
(3.) Find 36" / 8" column in table 1 and 24" hole diameter row at
right side of table.

Result:

Read up and over to intersection; finding max. angle of 15.51 degrees.


Max. angle is greater than proposed angle, so we are OK.

Table II on page 4.11 gives angle values for situations where the pipe centerline meets a
wall centerline at the inside face of the wall. See lower diagram on the "Pipe Angle Diagram" sheet. Application is restricted to walls whose inside width and thickness are given
at the bottom of the table. For walls with other dimensions, use the formula for 0 found at
the bottom of the "Pipe Angle Diagram" page. Note that dimension "L" has no effect in this
instance so table values can be used for non-standard box lengths.
Procedure is as given in example #1. Note, however, that a jog is formed in the line when
using this system. As a practical matter, given sufficient distance between structures, this
job can be eliminated by slightly angling the pipe in the hole. However, the designer
should consider this problem.

TITLE

Maximum Pipe Angle Tables


(Instructions / Examples)

STATE

SECTION PAGE

DATE

GA

11.8

12-01-10
HEIDELBERGCEMENT Group

Design Aids
D/2

D/2

CL
- See Note Below -

= Tan -1

D/2
W
- Sin -1 w2 + (L + T)2
L+T

Pipe CL Through Center of Structure - See Table I

CL

D/2

D/2

CL
L

CL

= Tan -1

W
T

D/2
- Sin -1

w2 + T2

Pipe CL Meets Structure CL @ Inside Wall - See Table II


NOTE:

"L" Values used in Table I to derive diameter are as given below; To find diameter for other values of "L" use formulas above.
17/6 - L = 14"
24/8 - L = 18"
27/8 - L = 131/2"

17" x 28"
24" x 36"
27" x 27"

"D-1" Box
"C" Box
"D-2" Box

28/6 - L = 81/2"
36/8 - L = 12"
42/6 - L = 21"

17" x 28"
24" x 36"
42" x 42"

"D-1" Box
"C" Box
D.O.T. "P" Box

48/8 - L = 12"
60/8 - L = 36"
72/8 - L =36"

48" x 24"
60" x 72"
72" x 72"

D.O.T. "F" Box


D.O.T. "J" Box
D.O.T. "J" Box

TITLE

Pipe Angle Diagram


Flat Wall Structures

-No ScaleAll dimensions subject to allowable


specification tolerances.

STATE

SECTION PAGE

DATE

GA

11.9

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Table I
Pipe CL through center of structure
(See note at bottom of Diagram Page 4.9)

Maximum Angle (Degrees)


0.00

72"

3.81

66"

7.44

0.00

60"

10.93

3.82

54"

14.32

7.50

0.00

17.61

11.06

7.95

0.00

20.83

14.53

15.01

6.12

0.00

36"

23.99

17.93

21.49

11.86

8.11

30"

25.03

19.05

23.57

13.71

10.64

0.00

27.10

21.27

27.60

17.34

15.51

7.46

3.92

0.00

24"

28.65

22.92

30.55

20.00

19.02

12.60

7.69

3.27

21"

30.18

24.56

33.45

22.62

22.45

17.48

11.36

6.46

18"

31.20

25.65

35.35

24.35

24.70

20.61

13.75

8.56

1.43

16"

32.22

26.74

37.24

26.06

26.91

23.67

16.12

10.63

4.24

14"

33.23

27.82

39.12

27.77

29.11

26.68

18.45

12.69

7.00

12"

34.24

28.90

40.98

29.47

31.28

29.63

20.76

14.73

9.73

10"

72"
8"

60"
8"

48"
8"

42"
6"

36"
8"

28"
6"

27"
8"

24"
8"

17"
6"

STATE

SECTION PAGE

48"

28"

Hole Diameters
(Inches)

42"

Inside Wall Dimension


Wall Thickness

TITLE

Max. Pipe Angle


Flat Wall Structures

GA

DATE

11.10 12-01-10
HEIDELBERGCEMENT Group

Design Aids

Table II
Pipe CL meets structure CL @ inside wall.

Maximum Angle (Degrees)


0.00

72"

13.99

66"

23.04

0.00

60"

30.41

14.66

54"

36.87

24.45

0.00

42.76

32.51

15.47

0.00

48.26

39.64

26.22

18.54

0.00

36"

53.47

46.18

35.21

30.67

16.45

30"

55.16

48.27

37.97

34.18

20.75

0.00

58.48

52.33

43.26

40.72

28.51

14.81

9.46

0.00

24"

60.93

55.30

47.05

45.31

33.83

23.22

17.34

9.58

21"

63.35

58.22

50.73

49.71

38.86

30.58

24.35

17.69

18"

64.94

60.14

53.14

52.56

42.08

35.11

28.69

22.61

4.50

16"

66.53

62.04

55.51

55.36

45.23

39.44

32.85

27.27

12.48

14"

68.11

63.93

57.85

58.10

48.31

43.60

36.87

31.72

19.55

12"

69.68

65.80

60.17

60.82

51.34

47.63

40.77

36.02

26.04

10"

72"
8"

60"
8"

48"
8"

42"
6"

36"
8"

28"
6"

27"
8"

24"
8"

17"
6"

STATE

SECTION PAGE

DATE

GA

11.11

12-01-10

48"

28"

Hole Diameters
(Inches)

42"

Inside Wall Dimension


Wall Thickness

TITLE

Max. Pipe Angle


Flat Wall Structures

HEIDELBERGCEMENT Group

Design Aids

Cross - Sectional Area


(Sq. in.) per ft.

Bar Size
Designation*

Weight
(Lbs. per foot)

Bar
Diameter
(inches)

#3
#4
#5

.376
.668
1.043

.375
.500
.625

.11
.20
.31

.66
.40
.62

#6
#7
#8

1.502
2.044
2.670

.750
.875
1.000

.44
.60
.79

.88
1.20
1.58

#9
#10
#11

3.400
4.303
5.313

1.128
1.270
1.410

1.00
1.27
1.56

2.00
2.54
3.12

#14
#18

7.650
13.600

1.693
2.257

2.25
4.00

4.50
8.00

At 12" C.-C.

At 6" C.-C.

* Bar numbers are based on the number of 1/8 inches included in the
nominal diameter. The nominal diameter of a deformed bar is equivalent
to the diameter of a plain bar having the same weight as the deformed bar.

TITLE

Rebar Chart

STATE

SECTION PAGE

DATE

GA

11.12

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Area - Sq. In. per Ft. of Width for Various Spacings


Wire Size Number

Nominal
Diameter
Inches

Nominal
Weight
Lbs./Lin. Ft.

Center to Center Spacing


3"

4"

6"

8"

10"

1.86
1.80
1.68

1.24
1.20
1.12

.93
.90
.84

.62
.60
.56

.465
.45
.42

.372
.36
.336

.31
.30
.28

.934
.816
.748

1.56
1.44
1.32

1.04
.96
.88

.78
.72
.66

.52
.48
.44

.39
.36
.33

.312
.288
.264

.26
.24
.22

0.504
0.478
0.451

.680
.612
.544

1.20
1.08
.96

.80
.72
.64

.60
.54
.48

.40
.36
.32

.30
.27
.24

.24
.216
.192

.20
.18
.16

D14
D12
D11

0.422
0.390
0.374

.476
.408
.374

.84
.72
.66

.56
.48
.44

.42
.36
.33

.28
.24
.22

.21
.18
.165

.168
.144
.132

.14
.12
.11

D10

0.366
0.356
0.348

.357
.340
.323

.63
.60
.57

.42
.40
.38

.315
.30
.285

.21
.20
.19

.157
.15
.142

.126
.12
.114

.105
.10
.095

0.338
0.329
0.319

.306
.289
.272

.54
.51
.48

.36
.34
.32

.27
.255
.24

.18
.17
.16

.135
.127
.12

.108
.102
.096

.09
.085
.08

0.309
0.298
0.288

.255
.238
.221

.45
.42
.39

.30
.28
.28

.225
.21
.195

.15
.14
.13

.112
.105
.097

.09
.084
.078

.075
.07
.065

0.276
0.264
.0252

.204
.187
.170

.36
.33
.30

.24
.22
.20

.18
.165
.15

.12
.11
.10

.09
.082
.075

.072
.066
.06

.06
.055
.05

0.240
0.225
0.211

.153
.136
.119

.27
.24
.21

.18
.16
.14

.135
.12
.105

.09
.08
.07

.067
.06
.052

.054
.048
.042

.045
.04
.035

W3
W2.9
W2.5

0.195
0.192
0.178

.102
.098
.085

.18
.174
.15

.12
.116
.10

.09
.087
.075

.06
.058
.05

.045
.043
.037

.036
.035
.03

.03
.029
.025

W2.1
W2
W1.5
W1.4

0.162
0.159
0.138
0.135

.070
.068
.051
.049

.126
.12
.09
.084

.084
.08
.06
.056

.063
.06
.045
.042

.042
.04
.03
.028

.031
.03
.022
.021

.025
.024
.018
.017

.021
.02
.015
.014

Smooth

Deformed

W31
W30
W28

D31
D30
D28

0.628
0.618
0.597

1.054
1.020
.952

W26
W24
W22

D26
D24
D22

0.575
0.553
0.529

W20
W18
W16

D20
D18
D16

W14
W12
W11
W10.5
W10
W9.5
W9
W8.5
W8
W7.5
W7
W6.5
W6
W5.5
W5
W4.5
W4
W3.5

D9
D8

D7

D6
D5

D4

2"

TITLE

Welded Wire Mesh Chart

STATE

GA

SECTION PAGE

11.13

12"

DATE

12-01-10
HEIDELBERGCEMENT Group

Design Aids
Most steel reinforcing designs in the precast industry use grade 40 rebar. The
yield strength of grade 40 rebar is 40,000 p.s.i. Steel cross sectional areas may
be reduced by using higher strength steels and still maintain equivalent yield
strengths.
The following chart has been developed to show equivalent yield strengths for
grade 40 rebar, and 65 k.s.i. welded wire mesh. The equivalent steel areas are
directly proportional to the yield strengths, therefore:
Grade 60 steel area = 40,000 / 60,000 x grade 40 steel area
65 k.s.i. welded wire mesh = 40,000 / 65,000 x grade 40 steel area

Grade 40 Rebar
Bar Size &
Spacing

Equivalent 65 K.S.I.
Welded Wire Mesh

Equivalent Grade 60 Rebar


Steel
Area

Bar Size &


Spacing

Min. Steel
Area

*Wire Size
& Spacing

Min. Steel
Area

.1230

#4@ 12" CCEW

.20

#3 @ 9 1/2" CCEW

.1333

W3.5/W3.5, 3" x 3"


or
W4.5/W4.5, 4" x 4"
or
W6.02/W6.2, 6" x 6"

#4 @ 6" CCEW

.40

#4 @ 9" CCEW
#5 @ 13 1/2" CCEW

.2666

W6.5/W6.5, 3" X 3"


or
W9/W9, 4" x 4"

.2461

#5 @ 12" CCEW

.31

#4 @ 11 1/2" CCEW

.2066

W5/W5, 3" x 3"


or
W5W6.7, 3" x 4"

.1907

#5 @ 6" CCEW

.62

#6 @12" CCEW
#5 @ 9" CCEW

.4133

W10/W10, 3" x 3"

.3815

#6 @ 12" CCEW

.44

#5 @ 12 1/2" CCEW

.2933

W6.5/W6.5, 3" x 3"

.2707

#6 @ 6" CCEW

.88

#6 @ 9" CCEW
#7 @ 12" CCEW

.5866

W14/W14, 3" x 3"

.5415

#7 @ 12" CCEW

.60

#6 @ 13" CCEW

.40

W9.5/W9.5, 3" x 3"

.3692

#7 @ 6" CCEW

1.20

#7 @ 9" CCEW

.80

W26/W26, 4" x 4"

.7385

#8 @ 12" CCEW

.79

#7 @ 13 1/2" CCEW

.5267

W26/W26, 6" x 6"

.4861

#8 @ 6" CCEW

1.58

#8 @ 9" CCEW

W26/W26, 3" x 3"

.9723

1.053

* Wire mesh sizes shown are examples only. Availability must be checked with the
mesh manufacturer.
TITLE

Steel Equivalency Chart

STATE

SECTION PAGE

DATE

GA

11.14

12-01-10
HEIDELBERGCEMENT Group

Design Aids

Cast Iron Products


Load Designations***
Classification

Application

Proof Load Test

Heavy Duty

Suitable for highway traffic loads, or 16,000 lb.


wheel loads.

Medium Duty

Suitable for driveways, parking lots, ramps


and other similar applications where wheel
loads do not exceed 12,000 lbs.

Light Duty

Suitable for pedestration areas such as


sidewalks, terraces and other areas which
do not receive vehicular traffic.

25,000 lbs.* (Ref: Fed. Spec. RR-F-621C)

18,000 lbs.*

* Proof load is applied over a 9" x 9" area in center of the casting and held for one
minute without failure or permanent deflection.

Steel Grating and Covers


Load Designations***
Classification

Traffic

Application
H-20

AASHTO H20: 16,000 lbs over 8" x 20" area.**

H-15

AASHTO H20: 12,000 lbs over 6.9" x 17.30" area.**

H-10

AASHTO H20: 8,000 lbs over 5.6" x 14.1" area.**


These grates and covers are not intended for traffic applications.
All our standard products exceed 300 PSF.

Non-Traffic

** Design includes 30% for impact. Load area is increased by twice the distance
center to center of the bearing bars in the direction perpendicular to the bearing
bars.
*** Load designation and classificatios are per U.S. Foundry & Mfg. Corp. Products as
shown in their 3rd addition catalog, copyright 1986.

TITLE

Casting Specifications

STATE

GA

SECTION PAGE

DATE

11.15 12-01-10
HEIDELBERGCEMENT Group

Engineering

Comparison of
ASTM C-76 Class Pipe
To
ASTM C-655 D-Load Pipe
D-Load Range

Class

1D to 800 D
801 D to 1,000 D
1,001 D to 1,350 D
1,351 D to 2,000 D
2,000 D to 3,000 D
Above 3,000 D

Class 1
Class 2
Class 3
Class 4
Class 5
No Equal Class Pipe

TITLE

ASTM C-76 & ASTM C655 Comparison

STATE

SECTION PAGE

DATE

GA

12.1

12-01-10
HEIDELBERGCEMENT Group

Engineering
Specifications Applicable to Concrete Pipe and Associated Precast Concrete Products

ASTM C14 /AASHTO M86 - Concrete Sewer, Storm Drain, and Culvert Pipe

ASTM C76 / AASHTO M170 - Reinforced Concrete Culvert, Storm Drain and Sewer Pipe

ASTM C361 - Reinforced Concrete Low Head Pressure Pipe

ASTM C443 /AASHTO M315 - Joints for Concrete Pipe and Manholes using Rubber Gaskets

ASTM C478 / AASHTO M199 - Precast Reinforced Concrete Manhole Sections

ASTM C497 - Test Methods for Concrete Pipe, Manhole Sections, or Tile

ASTM C506 / AASHTO M206 - Reinforced Concrete Arch Culvert, Storm Drain and Sewer Pipe

ASTM C507 / AASHTO M207 - Reinforced Concrete Elliptical Culvert, Storm Drain and Sewer Pipe

ASTM C655 - Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ASTM C789 / AASHTO M259 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers

ASTM C822 - Terminology Relating to Concrete Pipe and Related Products

ASTM C850 / AASHTO M273 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and
Sewers with Less Than 2 Feet of Cover Subjected to Highway Loadings

ASTM C890 - Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete
Water and Wastewater Structures

ASTM C913 - Precast Concrete Water and Wastewater Structures

ASTM C923 - Resilient Connectors Between Reinforced Concrete Manhole Structures and Pipes

ASTM C924 - Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method

ASTM C969 - Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe
Sewer Lines

ASTM C990 / AASHTO M198 - Specifications for Joints for Concrete Pipe, Manholes and Precast Box Sections
Using Preformed Flexible Joint Sealants

ASTM C1103 - Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines

ASTM C1131 - Practice for Least Cost (Life Cycle) Analysis of Concrete Culvert, Storm Sewer, and Sanitary
Sewer Systems

ASTM C1214 - Practice for Testing Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Method

ASTM C1244 - Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Method

ASTM C1417 - Specification for Manufacture of Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe

ASTM C1433 - Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers

ASTM C1577 - Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and

for Direct Design

Sewers Designed According to AASHTO LRFD

AWWA C302 - Reinforced Concrete Pressure Pipe, Non-Cylinder Type for Water and Other Liquids

U.S. Bureau of Reclamation - Standard Specifications for Reinforced Concrete Pressure Pipe

TITLE

Reference Specifications

STATE

SECTION PAGE

DATE

GA

12.2

12-01-10
HEIDELBERGCEMENT Group

Engineering

FULL FLOW CONSTANTS


for
Circular, Elliptical, Arch Pipes and Box Sections

Use of Tables
Substituting Different Products at Full Flow Conditions

Selection of pipe sizes for flows as determined by Manning's equation:


V = 1.486/n

R.66 S.5

Where; Q = A V
Substitute for V:
Q = A (1.486/n R.66 S.5)
Therefore: Q = K S.5

Example: Substitute a Box (or Boxes) for 2 - 30 inch Arch Pipes


K for 1 - 30 inch Arch Pipe = 368 (from table)
K for 2 - 30 inch Arch Pipes = 736
K for equivalent Box Culvert; 4' x 2' Box = 743 (from table)
Therefore a single 4' x 2' Box Culvert (RCB) will substitute.

CMA - Corrugated Metal Arch - use n = 0.024 for 2 2/3 x 1/2 inch & 0.027 for 3 x 1 inch
CMP - Corrugated Metal Circular Pipe - use n = 0.024
RCA - Reinforced Concrete Arch - use n = 0.012
RCB - Reinforced Concrete Box Culvert - use n = 0.012
RCE - Reinforced Concrete Elliptical - use n = 0.012
RCP - Reinforced Concrete Circular Culvert - use n = 0.012

A = Cross sectional area


V = Velocity (fps)
Q = Flow (cuft/sec)

R = Hydraulic radius = area/inside perimeter


S = Slope of line (feet/foot)
1 cu ft = 7.48 gallons

TITLE

Tables: Full Flow Constants

STATE

SECTION PAGE

DATE

GA

12.3

12-01-10
HEIDELBERGCEMENT Group

Engineering
Size / Type

Equivalent
Size

Area

Hydraulic
Radius

1.10
1.23
0.78
1.60

0.28
0.31
0.25
0.34

29
35
38
48

1.00
1.77
1.23
2.20

0.25
0.38
0.31
0.40

54
57
70
74

2.41
1.65
2.80
1.77

0.44
0.30
0.45
0.37

86
91
102
113

1.80
3.14
2.20
2.41

0.37
0.50
0.36
0.44

116
123
137
171

11 x 18
15
12
13 X 22

CMA
CMP
RCP
CMA

15
15

11 X 18
18
15
16 X 25

RCA
CMP
RCP
CMA

15

21
13 1/2 x 22
18 X 29
18

CMP
RCA
CMA
RCP

14 X 23
24
15 1/2 x 26
21

RCE
CMA
RCA
RCP

18

22 X 36
18 x 28 1/2
30
24

CMA
RCA
CMP
RCP

30
24

4.40
2.80
4.91
3.14

0.56
0.45
0.63
0.50

185
203
222
245

19 X 30
27 X 43
27
22 X 34

RCE
CMA
RCP
RCE

24
36

3.30
6.40
3.98
4.10

0.49
0.68
0.56
0.55

252
306
335
339

36
22 1/2 x 36 1/4
31 X 50
30

CMP
RCA
CMA
RCP

7.07
4.40
8.70
4.91

0.75
0.56
0.79
0.63

361
368
410
444

24 X 38
3X2
42
33

RCE
RCB
CMP
RCP

30

5.10
5.78
9.62
5.94

0.61
0.63
0.88
0.69

456
524
545
574

36 X 58
26 5/8 x 43 3/4
36
4X2

CMA
RCA
RCP
RCB

48
36

11.40
6.40
7.07
7.65

0.91
0.68
0.75
0.69

589
613
722
743

29 X 45
48
40 X 65
39

RCE
CMP
CMA
RCP

36

7.40
12.57
14.30
8.30

0.74
1.00
1.01
0.81

746
778
792
892

*31 5/16 x 51 1/8


3X3
5X2
44 X 72

RCA
RCB
RCB
CMA

42

8.656
8.78
9.50
17.60

0.78
0.78
0.74
1.12

911
923
961
1045

18

21
18
24

21

27
30
42

54

60

* - Revised 11-05-10
TITLE

Tables: Full Flow Constants

STATE

SECTION PAGE

DATE

GA

12.4

11-05-10
12-01-10
HEIDELBERGCEMENT Group

Engineering
Size / Type

Equivalent
Size

Area

Hydraulic
Radius

15.90
9.62
11.32
10.20

1.13
0.88
0.77
0.88

1066
1090
1098
1156

66

11.04
11.40
11.65
21.30

0.94
0.90
0.90
1.23

1311
1315
1340
1345

48

19.63
13.11
12.57
12.90

1.25
0.80
1.00
0.97

1410
1422
1556
1565

15.11
25.30
14.50
14.30

0.82
1.34
0.98
1.01

1639
1692
1770
1783

23.76
14.19
15.65
15.90

1.38
1.06
1.04
1.13

1818
1828
1990
2131

16.60
17.32
31.00
28.27

1.11
1.04
1.52
1.50

2196
2200
2256
2293

17.70
35.00
20.11
19.50

1.13
1.59
1.09
1.16

2376
2624
2637
2660

19.63
33.18
20.50
23.11

1.25
1.63
1.23
1.13

2821
2840
2910
3106

40.00
23.32
38.48
24.50

1.70
1.25
1.75
1.30

3135
3350
3460
3620

23.76
24.80
25.60
28.61

1.38
1.35
1.35
1.19

3636
3753
3867
3978

27.11
44.18
28.27
29.32

1.33
1.88
1.50
1.42

4050
4167
4587
4590

54
42
6X2
34 X 53

CMP
RCP
RCB
RCE

45
36 x 58 1/2
4x3
49 X 79

RCP
RCA
RCB
CMA

60
7X2
48
38 X 60

CMP
RCB
RCP
RCE

8X2
54 X 85
5X3
40 X 65

RCB
CMA
RCB
RCA

66
51
4X4
54

CMP
RCP
RCB
RCP

43 X 68
6X3
63 X 87
72

RCE
RCB
CMA
CMP

54

45 X 73
67 X 95
7X3
5x4

RCA
CMA
RCB
RCB

60
84

60
78
48 X 76
8X3

RCP
CMP
RCE
RCB

91 X 103
6X4
84
5x5

CMA
RCB
CMP
RCB

66
53 X 83
54 X 88
10 X 3

RCP
RCE
RCA
RCB

7X4
90
72
6X5

RCB
CMP
RCP
RCB

TITLE

Tables: Full Flow Constants

42
48

72
54

78

60
90

66
72

STATE

GA

SECTION PAGE

12.5

DATE

12-01-10
HEIDELBERGCEMENT Group

Engineering
Size / Type

Equivalent
Size

Area

Hydraulic
Radius

72

29.50
31.11
50.27
34.87

1.48
1.39
2.00
1.65

4734
4790
4940
5503

34.11
33.18
34.60
34.60

1.52
1.63
1.57
1.60

5590
5679
5784
5856

58 X 91
8X4
96
9X4

RCE
RCB
CMP
RCB

7X5
78
62 X 102
63 X 98

RCB
RCP
RCA
RCE

6X6
10 X 4
8X5
108

RCB
RCB
RCB
CMP

35.32
38.61
39.11
63.62

1.56
1.60
1.60
2.25

5880
6216
6630
6764

84
11 X 4
9X5
68 X 106

RCP
RCB
RCB
RCE

84

38.48
42.32
43.88
40.10

1.75
1.52
1.67
1.72

6920
6930
7654
7140

7X6
12 X 4
114
72 X 115

RCB
RCB
CMP
RCA

90

41.11
46.00
70.88
44.50

1.68
1.55
2.38
1.77

7200
7633
7823
8056

90
8X6
72 X 113
10 X 15

RCP
RCB
RCE
RCB

44.18
47.11
46.10
48.61

1.88
1.78
1.85
1.73

8321
8575
8584
8690

7X7
120
11 X 5
77 1/4 x 122

RCB
CMP
RCB
RCA

48.11
78.54
53.32
51.70

1.82
2.50
1.79
1.92

8880
8959
9733
9872

96
9X6
77 x 121
8x7

RCP
RCB
REC
RCB

50.27
52.88
52.40
55.11

2.00
1.87
1.97
1.94

9878
9950
10190
10600

12 X 5
10 X 6
102
82 X 128

RCB
RCB
RCP
RCE

58.00
58.61
56.75
59.20

1.83
1.95
2.13
2.09

10754
11300
11620
11980

9X7
8X8
11 X 6
108

RCB
RCB
RCB
RCP

61.88
63.11
64.32
63.62

2.05
2.07
2.02
2.25

12350
12700
12730
13530

87 1/8 x 138
87 X 136
10 X 7
12 X 6

RCA
RCE
RCB
RCB

66.00
66.40
68.61
70.00

2.17
2.22
2.14
2.08

13690
13970
14100
14100

TITLE

Tables: Full Flow Constants

84
78

90

96

96

102

108
108

STATE

SECTION PAGE

DATE

GA

12.6

12-01-10
HEIDELBERGCEMENT Group

Engineering

Size / Type

Equivalent
Size

Area

Hydraulic
Radius

9x8
114
11 X 7
10 X 8

RCB
RCP
RCB
RCB

70.88
70.88
75.32
78.61

2.20
2.38
2.22
2.31

14800
15620
15900
17000

9X9
12 X 7
120
96 7/8 x 154

RCB
RCB
RCP
RCA

79.88
82.00
78.54
81.80

2.33
2.30
2.50
2.42

17400
17689
17920
18312

97 X 151
11 X 8
10 X 9
12 X 8

RCE
RCB
RCB
RCB

82.00
86.32
88.61
94.00

2.46
2.41
2.46
2.50

18490
19200
20000
21400

11 X 9
10 X 10
132
12 X 9

RCB
RCB
RCP
RCB

97.32
98.61
95.03
106.00

2.57
2.59
2.75
2.67

22609
22894
23100
25268

11 X 10
144
12 X 10
11 X 11

RCB
RCP
RCB
RCB

108.32
113.10
118.00
119.32

2.72
3.00
2.83
2.85

26100
29132
29300
29700

12 X 11
12 X 12
15 X 15

RCB
RCB
RCB

130.00
142.00
223.00

2.98
3.11
3.87

33340
37500
68042

TITLE

Tables: Full Flow Constants

120
120

STATE

GA

SECTION PAGE

12.7

DATE

12-01-10