You are on page 1of 21

Bringing valuable

"water" to you

KAWAMOTO PUMP

AlternateParallel
Max 6 Pumps Rotary

Reliable Back up
Operation Function

Stainless Steel
Silent & Clean
PAT.

Ver. 1.1

KF2-AP

KF2-T

KF2-R

PUMPER

Energy-saving .
at estimated
water supply

Application Water supply to buildings,

Alternatealternate & parallel operation

KF2-AP

Compact 3 pumps rotary

PAT.

KF2

Accumulator (10R)
Control panel
Pressure transmitter
Check valve

Stainless steel pump


TEFC motor incorporated

Series products

Hot
water
85
Max

Check valve

Stainless steel
hot water pressure unit

Control panel

PUMPER KFH

Constant pressure at
estimated terminal outlet
40% energy-saving
operation
The pump speed is controlled by
an inverter according to the
fluctuations in the water amount
used, thereby reducing pressure
fluctuations at the estimated
terminal outlet, and leading to a
maximum 40% save in energy.
(Comparison of type KF2 and KAWAMOTO
conventional product KNV)
(Comparison of type KF2-R and KAWAMOTO
conventional product type KNVR)

Accumulator
(10R)

Ball valve
Stainless steel pump
TEFC motor incorporated

Refer to P.18

High power factor and


higher harmonic measures

Multi-function
control panel

Reliable backup
functions

Using the high power factor


devices *1 with a DC reactor
provided as a standard for each
pump, basic electricity rates can
be reduced by 5%(in Japan) and
the generation of higher
harmonics can be suppressed. *2
Complete measures against noise
are also taken with the surge killer
and noise filter for main circuit and
control circuit.

In addition to the inverter, earth


leakage circuit breaker (with
Alarm), digital voltage, current and
operation frequency display
provided for each pump, various
maintenance functions including a
cumulative operation hour,
cumulative number of starts
display and alarm buzzer are
provided for each pump. This
guarantees reliable protection
functions as well as long-term
stable water supply.
An inflow motorized valve circuit *
is also provided as a standard.

Water supply suspension are


avoided as much as possible with
the backup functions that kick in
when there is pump failure,
inverter failure as well as pressure
transmitter failure and control PCB
failure. (type KF2-R)

(A high efficiency noise filter is incorporated for


the type KF2-R.)
*1. Power factor 85.5% or more
*2. Complies with the "Higher harmonic
suppression measure procedures for
general-purpose inverter (input current 20A
or less) set by the Japan Electrical Machine
Industry Association.

Emergency back up operation


swich is equipped with for
avoiding water supply suspension
caused by control printed circuit
failure.

(* Excluding 0.75kW and below with Type KF2.)

Stainless Steel Precision Casting

Temperature detective function

Precision cast steel stainless steel is used for the pump's casing and flange, etc., so there is
no worry of strain.
For the water contact sections, stainless steel, resin and CAC (BC) parts are used so there
is no worry of red discolorment of water.

Thermo sensor for each pump is adopted

High-response, high-pumping properties

A heater terminal is provided as a standard making heater


installation easier.

A new control method with fast pressure response and small pressure fluctuation width has
been incorporated. Coupled with the high pumping performance provided with the high
efficiency 3D impeller enables quiet, powerful and smooth water supply.

Low-noise totally enclosed motor


A low-noise totally enclosed motor has been incorporated as a standard for all models. This
long-life motor is resistant against insulation deterioration caused by dust or moisture
absorption.

Compact and lightweight for installation work improvement


The type KF2 is a compact and lightweight unit with 520mm height (3.7kW or less) enabling
installation even under a reservoir tank.
With the type KF2, the suction and discharge flanges are arranged at the same direction,
and the discharge pipe is arranged at the center of the unit.
The volume of the type KF2-R has been reduced by up to 45% compared to the
conventional type SKF3.
The discharge direction can be set to either the left or right side.

Heater terminal
Individual sluice valve at discharge side
Sluice valve (stainless steel ball valve) at discharge side as
standard (except KF2-AP)

Unified domestic standards


Use with either 50Hz or 60Hz and positive or negative suction is
possible.

silent . clean . constant pressure


terminal outlet high-quality automatic
unit
factories, industry, small regional drinking water, other general water supply

Rotary operation multiple pump unit to handle even large water amount.
Operation of up to six pumps has been incorporated into a series

water supply unit

-T

KF2-R

PAT.

PAT. PEND.

3-partition hinge type control panel


(5-pump operation or more)

Control Panel

Dischharge
pipe

Earth leakage
circuit breaker

Heater terminal

Noise filter
(High efficiency noise absorb material)
Inverter (for each pump)

Earth leakage circuit breaker


(Control PCBheater)
Accumulator (20R)

Maintenance is easy since individual


ball valves are as aadopted

Pressure transmitter

Ball valve

Ball valve
Check valve

Stainless steel pump


TEFC motor incorporated

Standard specifications
Control method

Operation method

Constant pressure at estimated terminal outlet using frequency control


(constant discharge pressure also possible)
Alternate or alternate/parallel and multiple pump rotation
(max. six pump operation)

Installation place

Indoors (ambient temperature 0 to 40, humidity 90% or less, altitude 1,000m or less)

Liquid

Clean water, 0 to 40

Pump (material)

Motor

Stainless steel multi-stage turbine pump


(impeller: resin or CAC406 (BC6) or SCS13, shaft: water contact section SUS304, casing: SCS13)

Special specifications
Japan Center For Better Livingapproved product.
KF2 built-in sluice valve type (excluding suction bore
65mm models ,only for BL approved products)
CAC (BC) inpeller type (excluding suction bore32mm,
65mm and over 5.5kw models)
With Inflow motorized valve (solenoid valve)
circuit(in control box) below 0.75kW
With heater
Control panel position change
(excluding KF2-40T5.5, KF2-65T)
One stand-by pump unit type
(Excluding KF2-AP)
With emergency stop function circuit
Inflow solenoid
(KF2-R)
valve circuit

TEFC indoor : 3.7kW and below , TEFC outdoor : 5.5kW or over


No. of poles: 2 poles (max. frequency during automatic operation: 60 Hz)

Special accessories

Suction conditions

Positive suction0 to 5m (*1)or negative suctionsuction total head within -6m (*2) Pump coverFor KF2 (Steel plate, stainless steel)

Power supply

3 phase 380V440V (200V is also available), single phase 200V (KF2: 0.4, 0.75, 1.1kW)

Companion flange shape JIS 10K thin type


Paint color
(Munsell No.)

Control panel: gray (5Y7/1), accumulator: gray (10Y5.5/0.5), others: gray (2.5PB5.1/0.8)

(*1) 3m for 40-5.5kW, 50-7.5kW. Consult KAWAMOTO PUMP in ease of exceeding 5m positive suction
(*2) Suction actual head -within 4m, For 0.4kW, suction total head within -4m
Note) Consult KAWAMOTO PUMP for when using flashing valve and using the pump for long periods with small discharge amount.

Heater
Foot valvefor negative suction application)
Level relay (KF2-0.75kW and below,
low water level monitor)
Vibration proof bed
Electrode
Foundation bolt
Except special specification 400V models
using flash valve and (over 5.5kW) and
control panel position changed models

Connection to
change discharge
direction

KF2-AP
KF2-

Selection Table

KF2-A (Alternate operation of 2 pumps)

KF2-P(Alternate/parallel operation of 2 pumps)


100

100
50A7.5

80

80

50P7.5

40A5.5
60

40P5.5
60

65A7.5

32A1.9

40A3.7

50A5.5

50

50

Total
40
head
(m)

Total 40
head
(m)

40A2.2

32A1.1S2

50A3.7

40A1.5

65A5.5

40P2.2

32P1.1
S2

50P3.7

40P1.5

65P5.5

30

30

32P0.75S2

50A2.2

32A0.75S2

65A3.7

20

20

40A1.1

32A0.4S2
32A0.4 T

50P2.2

65P3.7

32P0.75

32A0.75

40P1.1

32P0.S2
32P0.
15

15
12
0.04 0.05 0.06

0.08

0.1

0.15

0.2

0.3

0.4

0.5 0.6 0.7

12
0.08

0.1

0.2

0.3

0.4

0.5

0.6 0.7 0.8 0.9 1.0

Flow rate (m3/min)

KF2-T 2/3 Pump Rotary (Special Specification)

KF2-T 3/3 Pump Rotary (Standard Specification)

100

100

80

80
50T7.5

40T5.5
60

60
32T1.9

40T3.7

50T5.5

50
32T1.1

40T2.2

50T3.7

32T1.9

40T3.7

1.3

50T7.5

65T7.5

50T5.5

50

65T7.5

Total
40
head
(m)

0.15

Flow rate (m3/min)

40T5.5

(100x2) l/min @ 4065P7.5


50P5.5
40P3.7
m

32P1.9

Total
40
head
(m)

65T5.5

32T1.1

50T3.7

40T2.2

65T5.5

30

30
32T0.75

40T1.5

50T2.2

32T0.75

65T3.7

40T1.5

50T2.2

65T3.7

20

20

15
0.1

0.2

0.3

0.4

0.5

0.6 0.7 0.8 0.9 1.0

1.5

15
0.1

0.2

0.3

Flow rate (m3/min)

0.4

0.5 0.6 0.7 0.8 0.9 1.0

1.5

2.0

Flow rate (m3/min)


(The specifications indicate the values with the unit loss from the check valve, etc., subtracted.)

Guide to Selection table


Total
head

Adjustable range
(The set head can be changed within this range)

Explanation of operation
Total
head

Alternate, Parallel

Unit characteristic curve (pump 1)


Unit characteristic curve
(pump 2)

P1
P2
P3

0 Q1
Pump stop flow rate

Q21 Q22

P1 : Set head
P2 : Estimated terminal head
P3 : Starting head (P2-0.04MPa {0.4kgf/cm2})
Q1 : Stop flow rate (10l/min)
Q21, Q22: Parallel-OFF, parallel-ON flow rate
The dotted line shows the case for constant
discharge pressure operation.

Flow rate

Flow rate
Flow rate at minumum set head

Flow rate at maximum set head

The total head is the value obtained by subtracting the loss caused by the
check valve (shock-less valve) from the pump performance.
When changing the set head, change it within the set head adjustment range.
The starting pressure is automatically adjusted to the pressure at estimated
terminal outlet -0.04MPa {0.4kg/cm2}.
The suction conditions must be set within the positive suction 5m to suction
total head -4m (-6m for 7.5kW). The maximum flow rate determined by the set
head will differ according to the suction conditions.

Alternate operation
When water is consumed while the pump is stopped and the pressure drops to
P3, the pump will start running.
When the flow rate is Q1 or higher, the pump will continue water supply at the
constant pressure at estimated terminal outlet.
When the used water rate drops to below Q1, the pump will stop.
Steps to are alternately repeated between the first pump and second pump.
Alternate/parallel operation
If the flow rate reaches Q22 or higher while the first pump is running, the
pressure sensor will activate and the second pump will start for parallel operation.
When the flow rate drops below Q21 during parallel operation, the pressure
sensor will activate, the pump started first will stop, and only one pump will run.
If the flow rate is less than Q21, alternate operation will take place.

Performance curves and technical information are sybject to change without notice. Consult KAWAMOTO PUMP for exact pump specifications.

KF2-AP
KF2-

Selection Table

KF2-A (Alternate operation of 2 pumps)

KF2-P(Alternate/parallel operation of 2 pumps)


100

100
50A7.5

80

80

50P7.5
(100x2) l/min
@ 40 m

40A5.5
60

40P5.5
60

65A7.5

32A1.9

40A3.7

50A5.5

Total 40
head
(m)

40A2.2

32A1.1S2

50A3.7

40A1.5

65A5.5

40P2.2

32P1.1
S2

50P3.7

40P1.5

65P5.5

30

30

32P0.75S2

50A2.2

32A0.75S2

65A3.7

20

20

40A1.1

32A0.4S2
32A0.4 T

50P2.2

65P3.7

32P0.75

32A0.75

40P1.1

32P0.S2
32P0.
15

15
12
0.04 0.05 0.06

0.08

0.1

0.15

0.2

0.3

0.4

0.5 0.6 0.7

12
0.08

0.1

0.2

0.3

0.4

0.5

0.6 0.7 0.8 0.9 1.0

Flow rate (m3/min)

KF2-T 2/3 Pump Rotary (Special Specification)

KF2-T 3/3 Pump Rotary (Standard Specification)

100

100

80

80
50T7.5

40T5.5
60

60
32T1.9

40T3.7

50T5.5

50
32T1.1

40T2.2

50T3.7

32T1.9

40T3.7

1.3

50T7.5

65T7.5

50T5.5

50

65T7.5

Total
40
head
(m)

0.15

Flow rate (m3/min)

40T5.5

65P7.5

50P5.5

40P3.7

50

50

Total
40
head
(m)

32P1.9

Total
40
head
(m)

65T5.5

32T1.1

50T3.7

40T2.2

65T5.5

30

30
32T0.75

40T1.5

50T2.2

32T0.75

65T3.7

40T1.5

50T2.2

65T3.7

20

20

15
0.1

0.2

0.3

0.4

0.5

0.6 0.7 0.8 0.9 1.0

1.5

15
0.1

0.2

0.3

Flow rate (m3/min)

0.4

0.5 0.6 0.7 0.8 0.9 1.0

1.5

2.0

Flow rate (m3/min)


(The specifications indicate the values with the unit loss from the check valve, etc., subtracted.)

Guide to Selection table


Total
head

Adjustable range
(The set head can be changed within this range)

Explanation of operation
Total
head

Alternate, Parallel

Unit characteristic curve (pump 1)


Unit characteristic curve
(pump 2)

P1
P2
P3

0 Q1
Pump stop flow rate

Q21 Q22

P1 : Set head
P2 : Estimated terminal head
P3 : Starting head (P2-0.04MPa {0.4kgf/cm2})
Q1 : Stop flow rate (10l/min)
Q21, Q22: Parallel-OFF, parallel-ON flow rate
The dotted line shows the case for constant
discharge pressure operation.

Flow rate

Flow rate
Flow rate at minumum set head

Flow rate at maximum set head

The total head is the value obtained by subtracting the loss caused by the
check valve (shock-less valve) from the pump performance.
When changing the set head, change it within the set head adjustment range.
The starting pressure is automatically adjusted to the pressure at estimated
terminal outlet -0.04MPa {0.4kg/cm2}.
The suction conditions must be set within the positive suction 5m to suction
total head -4m (-6m for 7.5kW). The maximum flow rate determined by the set
head will differ according to the suction conditions.

Alternate operation
When water is consumed while the pump is stopped and the pressure drops to
P3, the pump will start running.
When the flow rate is Q1 or higher, the pump will continue water supply at the
constant pressure at estimated terminal outlet.
When the used water rate drops to below Q1, the pump will stop.
Steps to are alternately repeated between the first pump and second pump.
Alternate/parallel operation
If the flow rate reaches Q22 or higher while the first pump is running, the
pressure sensor will activate and the second pump will start for parallel operation.
When the flow rate drops below Q21 during parallel operation, the pressure
sensor will activate, the pump started first will stop, and only one pump will run.
If the flow rate is less than Q21, alternate operation will take place.

Performance curves and technical information are sybject to change without notice. Consult KAWAMOTO PUMP for exact pump specifications.

Unit
bore

Suction
bore

mm

mm

Operation
method

Specifications table (Pump stop flow rate: 10R/min)

40
40

Alternate

32

50

50

40

65

50

80

65

50

32

40
80
50

100

65

50

32

40
80
50

100

65

Alternate/parallel

32

2/3 pump rotary

40

65

3/3 pump rotary

50

Type
KF2-32A0.4S2
KF2-32A0.4T
KF2-32A0.75S2
KF2-32A0.75
KF2-32A1.1S2
KF2-32A1.1
KF2-32A1.9
KF2-40A1.1
KF2-40A1.5
KF2-40A2.2
KF2-40A3.7
KF2-40A5.5
KF2-50A2.2
KF2-50A3.7
KF2-50A5.5
KF2-50A7.5
KF2-65A3.7
KF2-65A5.5
KF2-65A7.5
KF2-32P0.4S2
KF2-32P0.4T
KF2-32P0.75S2
KF2-32P0.75
KF2-32P1.1S2
KF2-32P1.1
KF2-32P1.9
KF2-40P1.1
KF2-40P1.5
KF2-40P2.2
KF2-40P3.7
KF2-40P5.5
KF2-50P2.2
KF2-50P3.7
KF2-50P5.5
KF2-50P7.5
KF2-65P3.7
KF2-65P5.5
KF2-65P7.5
KF2-32T0.75
KF2-32T1.1
KF2-32T1.9
KF2-40T1.5
KF2-40T2.2
KF2-40T3.7
KF2-40T5.5
KF2-50T2.2
KF2-50T3.7
KF2-50T5.5
KF2-50T7.5
KF2-65T3.7
KF2-65T5.5
KF2-65T7.5
KF2-32T0.75G
KF2-32T1.1G
KF2-32T1.9G
KF2-40T1.5G
KF2-40T2.2G
KF2-40T3.7G
KF2-40T5.5
KF2-50T2.2G
KF2-50T3.7G
KF2-50T5.5
KF2-50T7.5
KF2-65T3.7
KF2-65T5.5
KF2-65T7.5

Motor
Set head
Standard specifications
(Maximum
adjustment
number of
Total
Starting
range
pressure
operation units) Flow rate head Set head
m
m
m
m3/min
kW
MPa{kgf/cm2 }
1.6
0.4
0.16
1422
0.06
22
22

1.6
0.4
0.16
1422
0.06
22
22
2.5
0.75
0.25
2032
0.06
32

32
2.5
0.75
0.25
2032
0.065
32
32
4.4
1.1
0.43
3053
0.06
53

53
4.4
1.1
0.43
3053
0.06
53
53
5.5
1.9
0.54
4465
0.07
65
65
2.1
1.1
0.21
1428
0.145
28
28
2.5
1.5
0.25
2032
0.14
32
32
3.9
2.2
0.38
3048
0.14
48
48
5.5
3.7
0.54
4465
0.16
65
65
6.8
5.5
0.67
6080
0.19
80
80
2.5
2.2
0.25
2032
0.225
32
32
3.9
3.7
0.38
3048
0.265
48
48
5.9
5.5
0.58
4470
0.24
70
70
6.8
7.5
0.67
5680
0.28
80
80
2.5
3.7
0.25
2032
0.38
32
32
3.9
5.5
0.38
3048
0.35
48
48
5.0
7.5
0.49
4460
0.38
60
60
1.6
0.4 2
0.16
1422
0.12
22
22
1.6
0.4 2
0.16
1422
0.12
22
22
2.5
0.75 2
0.25
2032
0.12
32
32
2.5
0.75 2
0.25
2032
0.13
32
32
4.4
1.1 2
0.43
3053
0.12
53
53
4.4
1.1 2
0.43
3053
0.12
53
53
5.5
1.9 2
0.54
4465
0.14
65
65
2.1
1.1 2
0.21
1428
0.29
28
28
2.5
1.5 2
0.25
2032
0.28
32
32
3.9
2.2 2
0.38
3048
0.28
48
48
5.5
3.7 2
0.54
4465
0.32
65
65
6.8
5.5 2
0.67
6080
0.38
80
80
2.5
2.2 2
0.25
2032
0.45
32
32
3.9
3.7 2
0.38
3048
0.53
48
48
5.9
5.5 2
0.58
4470
0.48
70
70
6.8
7.5 2
0.67
5680
0.56
80
80
2.5
3.7 2
0.25
2032
0.76
32
32
3.9
5.5 2
0.38
3048
0.70
48
48
5.0
7.5 2
0.49
4460
0.76
60
60
2.5
0.75 2
0.25
2032
0.13
32
32
4.4
1.1 2
0.43
3053
0.12
53
53
5.5
1.9 2
0.54
4465
0.14
65
65
2.5
1.5 2
0.25
2032
0.28
32
32
3.9
2.2 2
0.38
3048
0.28
48
48
5.5
3.7 2
0.54
4465
0.32
65
65
6.8
5.5 2
0.67
6080
0.41
80
80
2.5
2.2 2
0.25
2032
0.45
32
32
3.9
3.7 2
0.38
3048
0.53
48
48
5.9
5.5 2
0.58
4470
0.5
70
70
6.8
7.5 2
0.67
5680
0.6
80
80
3.7 2
0.25
2032
0.76
32
32
2.5
5.5 2
0.38
3048
0.66
48
48
3.9
7.5 2
0.49
4460
0.76
60
60
5.0
0.75 3
0.25
2032
0.195
32
32
2.5
1.1 3
0.43
3053
0.18
53
53
4.4
1.9 3
0.54
4465
0.18
65
65
5.5
1.5 3
0.25
2032
0.42
32
32
2.5
2.2 3
0.38
3048
0.42
48
48
3.9
3.7 3
0.54
4465
0.48
65
65
5.5
5.5 3
0.67
6080
0.6
80
80
6.8
2.2 3
0.25
2032
0.59
32
32
2.5
3.7 3
0.38
3048
0.7
48
48
3.9
5.5 3
0.58
4470
0.78
70
70
5.9
7.5 3
0.67
5680
0.9
80
80
6.8
3.7 3
0.25
2032
1.12
32
32
2.5
5.5 3
0.38
3048
1.0
48
48
3.9
7.5 3
0.49
4460
1.14
60
60
5.0
()For single-phase 200V.

Accumulator
charged
pressure

Sound
(*1)

Power
factor

MPa{kgf/cm2 }
0.7
0.069
0.7
0.069
0.121.2
0.121.2
0.222.2
0.222.2
0.313.2
0.7
0.069
0.121.2
0.202.0
0.313.2
0.444.5
0.121.2
0.202.0
0.343.5
0.444.5
0.121.2
0.202.0
0.313.2
0.7
0.069
0.7
0.069
0.121.2
0.121.2
0.222.2
0.222.2
0.313.2
0.069
0.7
0.121.2
0.202.0
0.313.2
0.444.5
0.121.2
0.202.0
0.343.5
0.444.5
0.121.2
0.202.0
0.313.2
0.121.2
0.222.2
0.313.2
0.121.2
0.202.0
0.313.2
0.444.5
0.121.2
0.202.0
0.343.5
0.444.5
0.121.2
0.202.0
0.313.2
0.121.2
0.222.2
0.313.2
0.121.2
0.202.0
0.313.2
0.444.5
0.121.2
0.202.0
0.343.5
0.444.5
0.121.2
0.202.0
0.313.2

dBA
4143
4143
4750
4650
4851
4851
4855
4850
4952
4952
5556
5559
5254
5455
5860
5863
5456
5860
5862
4146
4146
4753
4653
4854
4854
4858
4853
4955
4955
5559
5562
5257
5458
5863
5866
5459
5863
5865
4653
4854
4858
4955
4955
5559
5562
5257
5458
5863
5866
5459
5863
5865
4657
4859
4859
4959
4959
5563
5566
5261
5463
5866
5867
5463
5865
5867

%
86.8
90.0
87.5
85.5
87.5
89.6
89.2
88.7
87.9
89.2
88.7
87.9
90.4
88.7
87.9
90.4
90.3
90.7
91.5
89.9
91.5
92.5
91.6
90.3
91.4
91.6
90.3
91.4
92.7
90.3
91.4
92.7
90.7
91.5
89.9
92.5
91.6
90.3
91.4
91.6
90.3
91.4
92.7
90.3
91.4
92.7
91.3
92.8
91.0
93.2
89.1
91.7
92.5
89.1
91.7
92.5
93.3
91.7
92.5
93.3

(1) The noise level is the maximum value given in the specifications. (Reference valve)

(Note) When using large amount flow rate such as a flushing valve, please consult KAWAMOTO PUMP.

Selection Table / Specifications Table

Specifications Table

KF2-AP Dimensions
Flange

160
125
179

Discharge Suction
bore
bore

3345

mm

310
345
438

50
40
50
65
80

BM
BL
TL

43
Remark)
Control panel bottom position,
there is no actual hole on the
base plate.

378445
510

40

253
140
169

mm
32
40
50
65
32
40
50
65

operation
method
Alternate

AlternateParallel

Alternate,
Parallel

Alternate

Flange
d1
1
PT1
4
1
PT1
2
PT2
PT2
1
PT1
4
1
PT1
2
PT2
1
PT22

g1
d2
1
PT1
2 100
1
PT1
2 105
1
PT1
2 120
PT2
140
1
PT1
2 100
PT2
105
1
PT2
2 120
PT3
140

g2
105
105
105
120
105
120
140
150

ST
25
25
27
31
25
25
27
31

DT
25
25
25
27
25
27
31
33

415
510

95

d2

n-M12

2
g

DT

PH

d1

DH

ST

1
g

SH

145169

70100

4-k1

FA

BD

100120
118

510

BS

BW

Discharge Suction
bore
bore
mm

Alternate

40
40

Alternate Parallel

50

50

65

40

32

50

40

65

80

Model

mm

32

is less than 0.75kWis 5.5 & 7.5kW


is bore 65mm

Dimensions

50

65

KF2-32A0.4S2
KF2-32A0.4T
KF2-32A0.75S2
KF2-32A0.75
KF2-32A1.1S2
KF2-32A1.1
KF2-32A1.9
KF2-40A1.1
KF2-40A1.5
KF2-40A2.2
KF2-40A3.7
KF2-40A5.5
KF2-50A2.2
KF2-50A3.7
KF2-50A5.5
KF2-50A7.5
KF2-65A3.7
KF2-65A5.5
KF2-65A7.5
KF2-32P0.4S2
KF2-32P0.4T
KF2-32P0.75S2
KF2-32P0.75
KF2-32P1.1S2
KF2-32P1.1
KF2-32P1.9
KF2-40P1.1
KF2-40P1.5
KF2-40P2.2
KF2-40P3.7
KF2-40P5.5
KF2-50P2.2
KF2-50P3.7
KF2-50P5.5
KF2-50P7.5
KF2-65P3.7
KF2-65P5.5
KF2-65P7.5

Motor
kW
0.4
0.4
0.75
0.75
1.1
1.1
1.9
1.1
1.5
2.2
3.7
5.5
2.2
3.7
5.5
7.5
3.7
5.5
7.5
0.4 2
0.4 2
0.75 2
0.75 2
1.1 2
1.1 2
1.9 2
1.1 2
1.5 2
2.2 2
3.7 2
5.5 2
2.2 2
3.7 2
5.5 2
7.5 2
3.7 2
5.5 2
7.5 2

Combination
SH
168
168
168
168
168
168
168
168
168
168
168
183
168
168
183
183
183
203
203
168
168
168
168
168
168
168
168
168
168
168
183
168
168
183
183
183
203
203

DH
363
363
363
363
363
363
363
363
363
363
363
396
363
363
396
396
421
465
465
363
363
363
363
363
363
363
363
363
363
363
396
363
363
396
396
421
465
465

PH
470
470
470
470
520
520
520
520
520
520
520
631
520
520
631
631
520
631
631
470
470
470
470
520
520
520
520
520
520
520
631
520
520
631
631
520
631
631

AD
100
100
100
100
100
100
100
100
100
100
100
118
100
100
118
118
120
120
120
100
100
100
100
100
100
100
100
100
100
100
118
100
100
118
118
120
120
120

W
930
930
930
930
930
930
930
930
930
930
930
1044
930
930
1044
1044
1018
1044
1044
930
930
930
930
930
930
930
930
930
930
930
1044
930
930
1044
1044
1018
1044
1044

Base
FA
-28
-28
-28
-28
2
2
2
-40
-40
2
2
13
-40
2
13
13
10
20
20
-28
-28
-28
-28
2
2
2
-40
-40
2
2
13
-40
2
13
13
10
20
20

TL

551
551
551

551
561

563

551
551
551

551
561

563

BL
535
535
535
535
535
535
535
535
535
535
535
650
535
535
650
650
650
650
650
535
535
535
535
535
535
535
535
535
535
535
650
535
535
650
650
650
650
650

BM
505
505
505
505
505
505
505
505
505
505
505
620
505
505
620
620
620
620
620
505
505
505
505
505
505
505
505
505
505
505
620
505
505
620
620
620
620
620

BW
910
910
910
910
910
910
910
910
910
910
910
1000
910
910
1000
1000
1000
1000
1000
910
910
910
910
910
910
910
910
910
910
910
1000
910
910
1000
1000
1000
1000
1000

Weight
BD
380
380
380
380
380
380
380
380
380
380
380
400
380
380
400
400
400
400
400
380
380
380
380
380
380
380
380
380
380
380
400
380
380
400
400
400
400
400

BS
125
125
125
125
125
125
125
125
125
125
125
145
125
125
145
145
145
145
145
125
125
125
125
125
125
125
125
125
125
125
145
125
125
145
145
145
145
145

kg
98
97
108
107
130
128
141
124
130
141
165
192
141
165
194
256
185
203
262
98
97
108
107
130
128
141
125
131
142
166
193
143
167
195
259
186
204
265

Vibration
proof bed

PJ-935A
RK-960
QGP-38
BK-970

PJ-1026A
QGP-55
BK-1060

PJ-935A
RK-960
QGP-38
BK-970

PJ-1026A
QGP-55
BK-1060

PJ-935A
RK-960
QGP-38
BK-970

PJ-1026A
QGP-55
BK-1060

PJ-935A
RK-960
QGP-38
BK-970

PJ-1026A
QGP-55
BK-1060

ECSG3 type
Digital display

Inverter, DC reactor and Earth leakage circuit breaker for


each pump
Noise filterEmergency back up operation function
Circuit for inflow motorized valve for twin reservoir
Compatible twin reservoir system (5-pole)
Type
Output
Operation method
Rated voltage

Trouble alarms Operation display Main components

Installation place

Photo : Example of ECSG3 (below 3.7kw

Inverter

External no-voltage signal

Functions

Earth leakage circuit breaker (ELB)

Heater
terminal

Earth leakage circuit breaker (with AL)


DC reactor
Noise filter
Inverter
Control PCB
Power supply
Operation
Discharge head
Power voltage, current, frequency
Cumulative operation time/No. of starts
Trouble
Pressure drop
Residual current
Pressure transmitter trouble
Full, water level dropping, empty
Water level control
Inflow motorized (solenoid) valve control

ECSG3-AP
1.1kW or more
A alternate, P alternate parallel
Single 200V, 3 phase 380440V (200V is also avaolable)
Indoors, altitude 1,000m or less, ambient
temperature 0 to 40, humidity 90% or less
For each pump
For each pump
For main circuit and control circuit
For each pump
With water level sensor
Lamp
Lamp (for each pump)
Digital
Digital
Digital
Lamp (for each pump)
Lamp (trouble message)
Lamp
Lamp (trouble message)
Lamp
Twin reservoir type (5-pole)
Twin reservoir type (3-pole)
(Automatic substitute operation [overload,
locking, phase failure, short circuit])

Pump trouble
Inverter trouble
Malfunction preventing retry
Buzzer
Operation
Trouble
Full
Water level dropping
Empty

(Automatic substitute operation)


(Refer to following table)
(With ON-OFF switch)
(independent)
(independent)

(*) When one special accessory level relay is provided.

List of trouble messages


Lamp display

Trouble
message

External
output

Retry

Trouble

OC1 to 3*

Over/undervoltage

Trouble
(overvoltage)

OV-LV

Trouble
(overvoltage)

Inverter heating
Memory error
Pressure drop
Pressure transmitter trouble

Trouble
Trouble
Trouble
Trouble

OH1
Er1
HdL
PEd

Heater switch

Inverter

Item

Noise filter

Emergency back up operation function is equipped

Display detail
Digital display
Power (red)

Operation (red)

(*) OL is displayed when the electronic thermal overload protection activates. (There is no retry.)

Full, Low, Empty alarm (orange)

Pump select switch


Reset switch

Overload
Locking, phase failure
Ground fault

Operation mode select switch

Dimensions / Control Panel

Control Panel

KF2-AP Control Panel Wiring Diagram


Example for 1.53.7kW
R S
Power Source
380 440V
50/60Hz

Noise filter
NF

Tr

ELB1
(AL)

ELB2
(AL)

Transmission
connector
Control
PCB

T P1 P()

U V

W G REV COM

U V

W G REV COM

INV2

Red

SW

White

Black

T P1 P()

CN11

Green

Red

INV1

Control
PCB

R S

Black

R S

White

DCL2

CN11
Transmission
connector

Green

DCL1

Emergency
back up
operation switch

Power
source

Cable pulling

Run
No.1

Cable pulling

No.2

No.1

Stop

M2

No.1 Pump

No.2 Pump

Manual

Shortage

Electric
Trouble leakage Trouble

Reset

M1

Full

Dry

No.2

Buzzer
Auto
ON

12
1

OFF

Tr

Transmission
connector

Pressure transmitter

NF

CN13

No.1 No.2

Function

Alternate

Close

Parallel

Auto

EL
Level relay

No.2

Outside
cut in

CN10

Flow sensor
(No.2 Pump)
Flow sensor
(No.1 Pump)

FS1
CN3

SW11-1 SW12-1 SW13-1


No.1
DIPSW
Open
Motorized valveopen Single

CN2

FS2
CN4

Touch panel

CN1
PS1

ELB1

CN5

CN9
Control PCB

CN7

CN11

CN12

CN14

ELB2

CN6

CN8

CN15

Chage

(AL)
(AL)

TB3
E3 E12 E11 E14 E15 E32 E31
TB2

No.1
Inflow
motorized
valve

No.2
Inflow
motorized
valve

E3 E22 E21 E24 E25 E42 E41

Shortage

Dry

Full

No.2 Trouble

No.1 Trouble

Common

No.2 Run

Common

Open

MV2

A1 A2 A3 A4 A5 A6 A7 A8 A9
No.1 Run

MV1
Prepare power
source separatly

Close

Open

Close

MV MV MV MV MV
0 11 12 21 22

Full
ON

Shortage
Motorized
OFF
valve
Dry
No.1 Reservoir

A1A9,MV0-MV22(output terminalno-voltage)
Terminal capacity250V-0.8A(induction load)
In case exceeding the above capacity, use it through a relay
In case connect power supply of motorized valve and the above
output terminal, be careful the terminal capacity
Resevoir terminal board
Disconnect short circuit beteween E3-E11E3-E15 in case using electrode bar
Connect short circuit between E3-E15E3-E25 in case not using water shortge
level monitor

Full

Close
Open

ON

Close
Open

Shortage
Motorized
OFF
valve
Dry
No.2 Reservoir

Connection of Inflow solenoid valve


Prepare

power source
separatly

Inflow motorized
SV1
valve
(Open at power on)
No.1

SV2
No.2

KF2-T

3 Pumps Rotary

Discharge Suction
bore
bore

mm
50

152
110

148

Flange

(0.753.7kW)

43

80

mm
32
40
50

d2
PT2
PT3
PT3

d1
1
PT1
4
1
PT1
2
PT2

Flange
g1 g2
100 120
105 150
120 150

ST
25
25
25

DT
27
33
33

n2
4
8
8

Dimensions
650

610

Discharge Suction
bore
bore

mm

mm

50

32
40

80
418

200

50

4-19

560

Motor

Combinations

Weight

kW
0.75 3
1.1 3
1.9 3
1.5 3
2.2 3
3.7 3
2.2 3
3.7 3

FA
32
2
2
44
2
2
44
2

kg
170
195
215
195
215
235
215
240

Model
KF2-32T0.75G
KF2-32T1.1G
KF2-32T1.9G
KF2-40T1.5G
KF2-40T2.2G
KF2-40T3.7G
KF2-50T2.2G
KF2-50T3.7G

Vibration
proof bed

QGP-10081424
or
PW-1102J311

DT

634

627

4-M12

g1

315

280

ST

FA

178

773

d2

g2

n2-19

4-Foundation bolt (M16)

280

100

1000

3 Pumps Rotary

Flange

(5.57.5kW) including 65T3.7

Discharge Suction
bore
bore

mm

265212
259148

80
100

760

720

Discharge Suction
bore
bore

mm
80

100
60

mm
40
50
65

d1
1
PT1
2
PT2
1
PT2
2

Flange
g1
d2
105 150
120 150
140 175

g2
105
120
140

ST
25
27
31

Dimensions

95163

6543
Remark)
Control panel bottom
position, there is no actual
hole on the base plate.

260

630

419

Model
mm
40 KF2-40T5.5
50 KF2-50T5.5
KF2-50T7.5
65 KF2-65T3.7
KF2-65T5.5
65
KF2-65T7.5

498418
DC
18

DH

4-M12

SH

1
g

Less bore 65

8-19

Less bore 50

d2

g2

is 3.7kW

d1

ST

FA
AD

355

350
1200

350

Control Panel Wiring Diagram / Dimensions

Dimensions

Motor
kW
5.5 3
5.5 3
7.5 3
3.7 3
5.5 3
7.5 3

Combinations
DH
669
669
669
736
781
781

SH
193
193
193
213
213
213

PH
882
882
882
841
886
886

AD
118
118
118
120
120
120

Weight
FA
13
13
13
10
20
20

DC
88
88
88
110
110
110

Vibration
proof bed
kg
350
359
PBKV-MBP106
425
or
273
PW-1301J231
368
437

KF2-T

Control Panel

ECSG3-T type (0.75kW3.7kW)

Noise filter
(High Efficiency Noise Absorb)

Digital display

Full, Low, Empty alarm


(orange)

Earth leakage circuit breaker

Component Parts Skelton

Display detail
Power (red)
Reset switch

Operation (red)

Operation mode select switch

(PHOTO : Example of 3 pump rotary 3.7kW Model)

Inverter (for each pump)

Heater switch
Heater
terminal

Digital display

ECSG3-T type (5.5kW7.5kW)

No. 1 pump manual oprtation switch for


preventing water supply suspension by
control circuit trouble

Noise filter (for each pump)


(High Efficiency Noise Absorb)

Digital display

Emergency back up operation function

Inverter
(for each pump)

Heater
terminal

Digital
display

Emergency back up operation function


Earth leakage circuit breaker

Earth leakage circuit breaker


(For Control PCBheater ) (200V only)

Inverter,DC reactor and residual current circuit breaker for each pumo
Noise filter, Circuit for inflow motorized valve for twin reservoir
Emergency backup operation function(1.57.5W)
Compatible twin reservoir system(5 pole)
ECSG3-T
3 pumps rotary
{2/3 or 3/3(standard)}

Installatrion place

Indoor, altitude 1,000m


or less, ambient temperature
0 to 40, humidity 90% or less

Trouble

Lamp(for each pump)

Residual current

Lamp

Pressure transmitter trouble

Lamp(trouble message)

Full, water level dropping, empty

Lamp

Water level control Twin reservoir type(5 pole)

For Each pump

Inflow motorized(solenoid)valve Twin reservoir type(3 pole)

DC reactor

For Each pump

Pump trouble

Automatic substitute operation

Inverter trouble

Automatic substitute operation

Noise filter
Inverter

High efficiency noise absortion materia incorporated


For Each pump

Control PCB

Control PCB, Display PCB

Power supply

Lamp

Operation

Lamp(for each pump)

Discharge head

Digital

Power voltage,current,frequency

Digital

Cumulative
operation time
No. of start

(1) 1.57.5kW

Digital

Functions

Earth leakage circuit breaker(with AL)

Disccharge pressure transmitter trouble


CPU trouble

Buzzar

(With ON-OFF switch)

Emergency backup operation (No.1inverter) 1


External nonvoltage signal

Operation display

main components

Operation method

Trouble display

Type

Operation

(independent)

Trouble

(independent)

Full

Water level

dropping

No. 1 pump manual oprtation switch for


preventing water supply suspension by
control circuit trouble

List of trouble message


Item
Sudden over current
(Locking, output side short circuit ,groud fault)
Electri thermal relay work(overload)
Low voltage
Excess voltage
Phase failure
Overheat
Memory trouble
CPU trouble
Communication trouble
Data save error at low voltage
Pressure drop
Pressure transmitter trouble
Control PCB trouble
Large flow rate operation

Inverter

(PHOTO : Example of 3 pump rotary 7.5kW Model)

Lightning
measures

Lamp display
trouble

Trouble External output


message (individual trouble) Retry
OC13

OL1/OLU
trouble
LU
trouble
OU13
trouble
OPL
trouble
OH1
trouble
Er1
trouble
Er3
trouble
Er8
trouble
ErF
trouble
HdL
trouble
Pressure
PEd
transmitter trouble
CPE
CPU trouble

PE2

Lightning surge protection are taken on the "Pumper


KF2 and KF2-R" as a standard. However, in special
installation places such as on mountain peaks or
when the earth resistance is large, the attenuation effect of
the lightning surge absorber will drop, so earth the earthing
wire to one point with the shortest distance, and always
provide special Class 3 (Class C) earthing from this device.

Less than 3.7kW

More than 5.5kW

Power source
AC380440V
50/60Hz
R S T

Power source
AC380440V
50/60Hz

E(G)
R

S T

E(G)

R0
T0

ELB2
(AL2)

ELB1
(AL1)

R S T E

ELB3
(AL3)

Noise filter

R0 S0 T0 R1

R S T E

R S T E

NF1
R0 S0 T0 E

RO

R S T E

NF2

NF3

R0 S0 T0 E

R0 S0 T0 E

To Control PCB
TO

U V W G REV COM
red
white
black
green

R S T G P1
INV2

Control
PCB
CN13-1

P()

DXB

U V W G REV COM

R S T G P1
INV3

Control
PCB
CN13-2

Emergency
back up
operation switch

Control
PCB
CN13-3

U V W G REV COM

red

black

M1

P()

DXB

T P1 P()

W G X1 CM

Cable Pullimg

M1

M2

M3

No.2Pump

No.3Pump

G R

T P1 P()

INV3
U

W G X1 CM

Control
PCB
CN13-3

M3

No.2Pump

No.3Pump
Power R0
Suppry
terminal T0

Cable Pullimg

No.1Pump

Control
PCB
CN13-2

M2
Emergency
back up
operation switch

No.1Pump

Power
supply
Cable Pullimg

green

red

W G X1 CM

INV2

red
white
black
green

P()

red
white
black
green

R S T G P1
INV1

V
white

U
DCL3

DCL2

DCL1

G R

black

Control
PCB
CN13-1

green

T P1 P()

DCL3

red

INV1

black

G R

DCL2

white

DCL1

ELB3
(AL)

green

ELB2
(AL)

white

ELB1
(AL)

Discharge pressure
transmitter error

Main CPU
error

Current
leakage
ON

Reset

Buzzer
ON

MCB

Full
Empty

10

R1
Tr1 T1

Tr2

Dry
OFF

OFF

Run

Run

Run

Trouble

Trouble

Trouble

Thermostat

FAN

R0 T0

Stop
Manual

(0.75kW~3.7kW)

Auto- Manual
matic

No.1

Tr1

Stop

Auto- Manual
matic

No.2

Stop

Automatic

No.3

Connector for inverter


Pressure transmitter
CN13-3 CN13-2 CN13-1

Chage

SW11-1 SW12-1 SW13-1


Single
Alternate
Parallel

Open
Close
Auto

No.1

EL
Level relay

Outside
cut in

CN10

No.2

AC200V
5A output

E3 E12 E11 E14 E15 E32 E31

Open

MV2

Prepare power
source separatly

No.1
Inflow
motorized
valve

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11

Common
No.1 Run
No.2 Run
No.3 Run
Common
No.1 Trouble
No.2 Trouble
No.3 Trouble
Dry
Full
Shortage

MV1

Close

Close

Not used

Open

MV MV MV MV MV
0 11 12 21 22

No.2
Inflow
motorized
valve

CN8 CN7 CN6

Motorized valveopen

CN15

DIPSW

No.2

Function

CN2

FS1
CN3

CN14

No.1

CN17

Tr1

Control PCB

Touch panel

CN1
PS1
FS2
CN4

(5.5kW, 7.5kW)

CN11

CN10 CN9

CN16

FS3
CN5

R1 T1

Control Panel / Control Panel Wiring Diagram

Control Panel Wiring Diagram

E3 E22 E21 E24 E25 E42 E41

Full
ON

Close
Open

OFF Shortage Motorized


valveopen
Dry
No.1 Reservoir

Full
ON

Close
Open

OFF Shortage Motorized


valveopen
Dry
No.2 Reservoir

Flow sensor
(No.3Pump)
Flow sensor
(No.2Pump)
Flow sensor
(No.1Pump)
ELB1
ELB2
ELB3

(AL)

Connection of Inflow solenoid valve


Prepare power MV MV MV MV MV
source separatly 0 11 12 21 22

Inflow solenoid
SV1
valve
(Open at power on) No.1

SV2
No.2

(AL)
(AL)

A1A11,MVO-MV22(output terminalno-voltage)
Terminal capacity250V-0.8A(induction load)
In case exceeding the above capacity, use it
through a relay
In case connect power supply of motorized valve
and the above output terminal, be careful the
terminal capacity
Resevoir terminal board
Disconnect short circuit beteween E3-E11E3E15 in case using electrode bar
Connect short circuit between E3-E15E3-E25 in
case not using water shortge level monitor

KF2-R

Selection Table

KF2-R3 2/3 Pumps Rotary

KF2-R34 3/3, 3/4 Pumps Rotary


100

100

50R3-7.5

40R3-5.5

3
40R-5.5
4

60

60

40R3-3.7

32R3-1.9

32R3-1.1

40R3-2.2

50R3-3.7

3
40R-3.7
4

3
32R-1.1
4

Total
head 40
(m)

65R3-5.5

32R3-0.75

40R3-1.5

50R3-2.2

65R3-3.7

3
65R-5.5
4

3
50R-2.2
4

3
40R-1.5
4

3
32R-0.75
4

3
65R-3.7
4

20

20

15
0.1

0.2

0.4

0.3

0.5

0.6

1.0

0.8

1.5

15
0.1

0.2

Flow rate (m3/min)

0.3

0.4

0.5 0.6

0.8

1.0

1.5

2.0

Flow rate (m3/min)

KF2-R45 4/4, 4/5 Pumps Rotary

KF2-R56 5/5, 5/6 Pumps Rotary


100

100
4

80

80

50R-7.5
5

60

32R-1.9
5

50R-7.5
6

40R-5.5
5

11

3
50R-3.7
4

3
40R-2.2
4

30

30

3
65R-7.5
4

3
50R-5.5
4

50

65R3-7.5

40

3
32R-1.9
4

50R3-5.5

50

Total
head
(m)

3
50R-7.5
4

80

80

40R-5.5
6

60

40R-3.7
5

65R-7.5
5

50R-5.5
5

50

32R-1.9
6

50R-5.5
6

50

Total
head 40
(m)

Total
head 40
(m)

50R-3.7
5

32R-1.1
5

40R-2.2
5

4
65R-5.5
5

50R-3.7
6

32R-1.1
6

5
40R-2.2
6

65R-5.5
6

30

30

50R-2.2
5

4
40R-1.5
5

4
32R-0.75
5

5
32R-0.75
6

50R-2.2
6

5
40R-1.5
6

5
65R-3.7
6

65R-3.7
5
20

65R-7.5
6

40R-3.7
6

20

15
0.15

0.2

0.3

0.4

0.5 0.6

0.8

1.0

2.0

1.5

3.0

15
0.2

0.3

0.4

Flow rate (m3/min)

0.8

1.0

100
80

50R6-7.5

65R6-7.5

50R6-5.5
50R6-3.7

32R6-1.1

40R6-2.2

0 Q1

65R6-5.5

30
50R6-2.2
32R6-0.75

40R6-1.5
65R6-3.7

20

15
0.2

0.3

0.4

0.5 0.6

0.8

1.0

4.0

P1: Set head


P2: Estimated terminal head
P3: Starting head
(P2-0.04MPa {0.4kg/cm2})
Q1: Stop flow rate (10l/min)
Q21, Q22: 2nd pump ON/OFF flow rate
Q31, Q33: 3rd pump ON/OFF flow rate
Q41, Q42: 4th pump ON/OFF flow rate
* The dotted line shows the case for
constant discharge pressure operation.

P3

50

Total
head 40
(m)

3.0

Example for four-pump rotary

P2

40R6-5.5
40R6-3.7

2.0

Explanation of operation
Total
head
P1

32R6-1.9

1.5

Flow rate (m3/min)

KF2-R6 6/6 Pumps Rotary

60

0.5 0.6

1.5

2.0

3.0

4.0

Flow rate (m3/min)


(The specifications indicate the values with the unit loss from the check valve, etc., subtracted.)

Q21 Q22 Q31 Q32 Q41 Q42

Flow rate

When water is used while the pump is stopped and the pressure drops to P3, the
pump will start running.
When the flow rate is between Q1 and Q21 or more, the water supply will continue
at the constant pressure at estimated terminal outlet.
When the flow rate drops to below Q1, the pump will stop.
If the flow rate is less than Q21, alternate operation will take place.
If the flow rate reaches Q22 or higher while the first pump is running, the second
pump will start up and two-pump operation will take place. If the flow rate increases
more, the pumps will start up in order of the third pump and fourth pump as Q32 and
Q42 are reached, and operation of up to four pumps will take place.
When the flow rate drops below Q41 during four-pump operation, the pressure
detector will activate, and the number of operating pumps will be reduced to three
pumps. If the used water rate drops further to Q31 or Q21, the pumps will be
reduced accordingly, and either two-pump or one-pump operation will take place.
When the flow rate drops to below Q1, the pump will stop.

Performance curves and technical information are sybject to change without notice. Consult KAWAMOTO PUMP for exact pump specifications.

32

80

40

100

50

125

65

65

32

80

40

100

50

125

65

65

32

80

40

100

50

125

65

80

32

100

40

125

50

150

65

80

32

100

40

125

50

150

65

2/3 pumps rotary

65

3/3,3/4 pumps rotary

mm

4/4,4/5 pumps rotary

mm

5/5,5/6 pumps rotary

Suction
bore

6/6 pumps rotary

Unit
bore

Operation
method

Specifications table (Pump stop flow rate: 10R/min)


Type
KF2-32R3-0.75G
KF2-32R3-1.1G
KF2-32R3-1.9G
KF2-40R3-1.5G
KF2-40R3-2.2G
KF2-40R3-3.7G
KF2-40R3-5.5G
KF2-50R3-2.2G
KF2-50R3-3.7G
KF2-50R3-5.5G
KF2-50R3-7.5G
KF2-65R3-3.7G
KF2-65R3-5.5G
KF2-65R3-7.5G
KF2-32R3
4
-0.75G
KF2-32R3
4
-1.1G
KF2-32R3
4
-1.9G
KF2-40R3
4
-1.5G
KF2-40R3
4
-2.2G
KF2-40R3
4
-3.7G
KF2-40R3
4
-5.5G
KF2-50R3
4
-2.2G
KF2-50R3
4)-3.7G
KF2-50R3(4
-5.5G
KF2-50R3
4
-7.5G
KF2-65R3
4
-3.7G
KF2-65R3
4
-5.5G
KF2-65R3
4
-7.5G
KF2-32R4
5-0.75G
KF2-32R4
5-1.1G
KF2-32R4
5-1.9G
KF2-40R4
5-1.5G
KF2-40R4
5-2.2G
KF2-40R4
5-3.7G
KF2-40R4
5-5.5G
KF2-50R4
5-2.2G
KF2-50R4
5-3.7G
KF2-50R4
5-5.5G
KF2-50R4
5-7.5G
KF2-65R4
5-3.7G
KF2-65R4
5-5.5G
KF2-65R4
5-7.5G
-0.75G
KF2-32R5
6
KF2-32R5
6
-1.1G
KF2-32R5
6
-1.9G
KF2-40R5
6
-1.5G
KF2-40R5
6
-2.2G
KF2-40R5
6
-3.7G
KF2-40R5
6
-5.5G
KF2-50R5
6
-2.2G
KF2-50R5
6)-3.7G
KF2-50R5(6
-5.5G
KF2-50R5
6
-7.5G
KF2-65R5
6
-3.7G
KF2-65R5
6
-5.5G
KF2-65R5
6
-7.5G
KF2-32R6-0.75G
KF2-32R6-1.1G
KF2-32R6-1.9G
KF2-40R6-1.5G
KF2-40R6-2.2G
KF2-40R6-3.7G
KF2-40R6-5.5G
KF2-50R6-2.2G
KF2-50R6-3.7G
KF2-50R6-5.5G
KF2-50R6-7.5G
KF2-65R6-3.7G
KF2-65R6-5.5G
KF2-65R6-7.5G

Motor
Set head
Standard specifications
(Maximum
adjustment
Total
Starting
number of
range
pressure
operation units) Flow rate head Set head
m
m
m
m3/min
kW
MPa{kgf/cm2 }
2.5
0.75 2
0.25
2032
0.13
32
32
4.4
1.1 2
0.43
3053
0.12
53
53
5.5
1.9 2
0.54
4465
0.12
65
65
2.5
1.5 2
0.25
2032
0.28
32
32
3.9
2.2 2
0.38
3048
0.28
48
48
5.5
3.7 2
0.54
4865
0.32
65
65
6.8
5.5 2
0.67
6080
0.41
80
80
2.5
2.2 2
0.25
2032
0.4
32
32
3.9
3.7 2
0.38
3048
0.47
48
48
5.9
5.5 2
0.58
4470
0.5
70
70
6.8
7.5 2
0.67
6080
0.6
80
80
2.5
3.7 2
0.25
2032
0.76
32
32
3.9
5.5 2
0.38
3048
0.66
48
48
5.0
7.5 2
0.49
4460
0.76
60
60
2.5
0.75 3
0.25
2032
0.195
32
32
4.4
1.1 3
0.43
3053
0.18
53
53
5.5
1.9 3
0.54
4465
0.18
65
65
2.5
1.5 3
0.25
2032
0.42
32
32
3.9
2.2 3
0.38
3048
0.42
48
48
5.5
3.7 3
0.54
4865
0.48
65
65
6.8
5.5 3
0.67
6080
0.6
80
80
2.5
2.2 3
0.25
2032
0.59
32
32
3.9
3.7 3
0.38
3048
0.7
48
48
5.9
5.5 3
0.58
4470
0.78
70
70
6.8
7.5 3
0.67
6080
0.9
80
80
2.5
3.7 3
0.25
2032
1.12
32
32
3.9
5.5 3
0.38
3048
1.0
48
48
5.0
7.5 3
0.49
4460
1.14
60
60
2.5
0.75 4
0.25
2032
0.26
32
32
4.4
1.1 4
0.43
3053
0.24
53
53
5.5
1.9 4
0.54
4465
0.24
65
65
2.5
1.5 4
0.25
2032
0.56
32
32
3.9
2.2 4
0.38
3048
0.56
48
48
5.5
3.7 4
0.54
4865
0.64
65
65
6.8
5.5 4
0.67
6080
0.8
80
80
2.5
2.2 4
0.25
2032
0.79
32
32
3.9
3.7 4
0.38
3048
0.94
48
48
5.9
5.5 4
0.58
4470
1.1
70
70
6.8
7.5 4
0.67
6080
1.19
80
80
2.5
3.7 4
0.25
2032
1.52
32
32
3.9
5.5 4
0.38
3048
1.3
48
48
5.0
7.5 4
0.49
4460
1.52
60
60
2.5
0.75 5
0.25
2032
0.325
32
32
4.4
1.1 5
0.43
3053
0.3
53
53
5.5
1.9 5
0.54
4465
0.3
65
65
2.5
1.5 5
0.25
2032
0.7
32
32
3.9
2.2 5
0.38
3048
0.7
48
48
5.5
3.7 5
0.54
4865
0.8
65
65
6.8
5.5 5
0.67
6080
1.0
80
80
2.2 5
0.25
2032
0.98
32
32
2.5
3.7 5
0.38
3048
1.17
48
48
3.9
5.5 5
0.58
4470
1.3
70
70
5.9
7.5 5
0.67
6080
1.48
80
80
6.8
3.7 5
0.25
2032
1.87
32
32
2.5
5.5 5
0.38
3048
1.62
48
48
3.9
7.5 5
0.49
4460
1.9
60
60
5.0
0.75 6
0.25
2032
0.39
32
32
2.5
1.1 6
0.43
3053
0.36
53
53
4.4
1.9 6
0.54
4465
0.36
65
65
5.5
1.5 6
0.25
2032
0.84
32
32
2.5
2.2 6
0.38
3048
0.84
48
48
3.9
3.7 6
0.54
4865
0.96
65
65
5.5
5.5 6
0.67
6080
1.2
80
80
6.8
2.2 6
0.25
2032
1.18
32
32
2.5
3.7 6
0.38
3048
1.4
48
48
3.9
5.5 6
0.58
4470
1.56
70
70
5.9
7.5 6
0.67
6080
1.78
80
80
6.8
3.7 6
0.25
2032
2.24
32
32
2.5
5.5 6
0.38
3048
1.95
48
48
3.9
7.5 6
0.49
4460
2.28
60
60
5.0

(*1)The noise level is the maximum value given in the specifications. (Reference value)
(Note) When using large amount flow rate such as a flushing valve, please consult KAWAMOTO PUMP.

Accumulator
charged
pressure
MPa{kgf/cm2 }
1.9
0.19
3.4
0.33
4.3
0.42
1.9
0.19
3.0
0.29
4.3
0.42
5.9
0.58
1.9
0.19
3.0
0.29
5.1
0.50
5.9
0.58
1.9
0.19
3.3
0.32
4.3
0.42
1.9
0.19
3.4
0.33
4.3
0.42
1.9
0.19
3.0
0.29
4.3
0.42
5.9
0.58
0.19
1.9
0.29
3.0
0.50
5.1
0.58
5.9
0.19
1.9
0.32
3.3
0.42
4.3
0.19
1.9
0.33
3.4
0.42
4.3
0.19
1.9
0.29
3.0
0.42
4.3
0.58
5.9
0.19
1.9
0.29
3.0
0.50
5.1
0.58
5.9
0.19
1.9
0.32
3.3
0.42
4.3
0.19
1.9
0.33
3.4
0.42
4.3
0.19
1.9
0.29
3.0
0.42
4.3
0.58
5.9
0.19
1.9
0.29
3.0
0.50
5.1
0.58
5.9
0.19
1.9
0.32
3.3
0.42
4.3
0.19
1.9
0.33
3.4
0.42
4.3
0.19
1.9
0.29
3.0
0.42
4.3
0.58
5.9
0.19
1.9
0.29
3.0
0.50
5.1
0.58
5.9
0.19
1.9
0.32
3.3
0.42
4.3

Sound
(*1)

Power
factor

dBA
53
54
58
55
55
59
62
57
58
63
66
59
63
65
57
59
59
59
59
63
66
61
63
66
67
63
65
67
59
61
61
61
61
65
68
63
65
67
68
64
66
69
60
62
62
62
62
66
69
64
66
68
69
65
67
70
61
63
63
63
63
67
70
65
67
69
70
66
68
71

%
90.7
91.5
89.9
92.5
91.6
90.3
91.4
91.6
90.3
91.4
92.7
90.3
91.4
92.7
91.3
92.8
91.0
93.2
89.1
91.7
92.5
89.1
91.7
92.5
93.3
91.7
92.5
93.3
87.8
87.2
89.9
90.3
92.3
93.2
90.3
92.3
93.2
93.6
92.3
93.2
93.6
90.2
90.2
90.8
91.7
92.7
93.4
91.7
92.7
93.4
93.6
92.7
93.4
93.6
90.8
90.8
91.4
92.1
93.4
93.5
92.1
93.4
93.5
93.7
93.4
93.5
93.7

Selection Table / Specifications Table

Specifications Table

12

KF2-R

Dimensions

434
<469>
479

3 Pumps Rotary

in 3 pumps and 4 pumps )


Flange ( Common
rotary operation models.

4 Pumps Rotary

Unit
bore

suction
bore

mm

mm

65

32

80

40

100

50

125

65

Recommended position
for able tube discharge

147
<145>
135

142

35

65 <75>
Remark)
Control panel bottom position,
there is no actual hole on the base plate.

305

g2 n2
140 4
140 4
140 4
150 8
150 8
150 8
175 8
175 8
210 8

k2 ST
19 25
19 25
19 25
19 25
19 25
19 25
19 27
19 27
23 31

142

558

1287<1250>

d2
65
65
65
80
80
80
100
100
125

Recommended position
for able tube discharge

<310>
380

<424>
404

175

Flange
g1
d1
1
PT1
4 100
1
PT14 100
1
PT1
4 100
1
PT1
2 105
1
PT12 105
1
PT1
2 105
PT2 120
PT2 120
1
PT22 140

1000<750>

230<200>
147

700<550>

65<75>
175

Remark)
Control panel bottom position,
there is no actual hole on the base plate.

1562<1550>

1250<1000>

175
<160>

(Remark)

FA

230<200>
8-k2

g2

4-foundation bolt(M16) AD

4-M12

630
670

1000<900>
125
275<210> 350<320> 350<320> 275<210>
1250<1120>

13

d2

g1

L
(Remark)
Prepare pump maintenance space behind
electric motor, not install electric cable

d1

125

4-foundation bolt(M16)
400 <370>

700<690>

700<550>

d1

ST

DH

DH
SH

g1

625<500>

d2

4-M12

625<500>

g2

SH

175
<160>

<145>
165

8-k2

ST

(Remark)

FA

AD

450 <430>

630<560>

225<210> 350<320> 350<320> 350<320> 275<270>

670<600>

1550<1440>

L
(Remark)
Prepare pump maintenance space behind
electric motor, not install electric cable

4 pumps rotary

3 pumps rotary

Dimension table
Unit
bore

suction
bore

mm

mm

65

32

80

100

40

50

125

65

65

32

80

100

125

40

50

65

There are holes also for power supply cable(with rubber bush) below 3.7kw models.
is less than 3.7kW models. (is 65mm-3.7kW model. Foundation bolts are optional accessory.

type
KF2-32R3-0.75G
KF2-32R3-1.1G
KF2-32R3-1.9G
KF2-40R3-1.5G
KF2-40R3-2.2G
KF2-40R3-3.7G
KF2-40R3-5.5G
KF2-50R3-2.2G
KF2-50R3-3.7G
KF2-50R3-5.5G
KF2-50R3-7.5G
KF2-65R3-3.7G
KF2-65R3-5.5G
KF2-65R3-7.5G
KF2-32R4-0.75G
KF2-32R4-1.1G
KF2-32R4-1.9G
KF2-40R4-1.5G
KF2-40R4-2.2G
KF2-40R4-3.7G
KF2-40R4-5.5G
KF2-50R4-2.2G
KF2-50R4-3.7G
KF2-50R4-5.5G
KF2-50R4-7.5G
KF2-65R4-3.7G
KF2-65R4-5.5G
KF2-65R4-7.5G

L is omitted in case L600.


shows reverse direction to the drawing

Motor
kW
0.75
1.1
1.9
1.5
2.2
3.7
5.5
2.2
3.7
5.5
7.5
3.7
5.5
7.5
0.75
1.1
1.9
1.5
2.2
3.7
5.5
2.2
3.7
5.5
7.5
3.7
5.5
7.5

Combinations
SH
178
178
178
178
178
178
228
178
178
228
228
228
248
248
178
178
178
178
178
178
228
178
178
228
228
228
248
248

DH
676
676
676
676
676
676
745
676
676
745
745
809
854
854
676
676
676
676
676
676
745
676
676
745
745
809
854
854

FA
23
7
7
35
7
7
15
35
7
15
15
8
8
8
23
7
7
35
7
7
15
35
7
15
15
8
8
8

Weight
L
611
611
611
611
689
613
613
691
691
689
689
689
611
611
611
611
689
613
613
691
691
689
689
689

AD
95
95
95
95
95
95
90
95
95
90
90
92
92
92
95
95
95
95
95
95
90
95
95
90
90
92
92
92

kg
202
230
248
227
250
270
403
250
275
409
476
368
440
507
256
295
319
291
322
347
527
321
353
532
622
463
572
657

Vibration Proof bed


PW-1101J221

QGP-88

PW-1101J221-1

QGP-92

PW-1301J221

QGP-88

PW-1101J221-1
PW-1301J221
PW-1301J221-1

QGP-92

PW-1301J221
PW-1301J221-1
PW-1451J351

QGP-89

PW-1451J351-1

QGP-93

PW-1601J281

PW-1451J351-2

QGP-89

PW-1451J351-1
PW-1451J351-2
PW-1601J281
PW-1601J281-1

QGP-93

PW-1601J281
PW-1601J281-1

5 Pumps Rotary

6 Pumps Rotary

Unit suction
bore
bore

k2 ST
19 25
19 25
19 25
19 25
19 25
19 25
19 27
19 27
23 31

147
<145>
165

1500<1250>

142

Remark)
Control panel bottom position,
there is no actual hole on the base plate.

1900 <1760>

g2 n2
150 8
150 8
150 8
175 8
175 8
175 8
210 8
210 8
240 8

305
<325>
360

633
<375>
355

65<75>

175

d2
80
80
80
100
100
100
125
125
150

333
<325>
305

333
<305>

142

633
<325>
305

147
<145>
165

Recommended position
for able tube discharge

Recommended position
for able tube discharge

Frange

mm
g1
mm
d1
1
PT1
4 100
1
80
32 PT1
4 100
1
PT1
4 100
1
PT1
2 105
1
100
40 PT1
2 105
1
PT12 105
PT2 120
125
50
PT2 120
1
150
65 PT22 140

305
<290>
360

Dimensions

in 5 pumps and 6 pumps )


Flange ( Common
rotary operation models.

230<200>
8-k2

g2

4-M12

65<75>

700<550>

175
<160>

Remark)
Control panel bottom position,
there is no actual hole on the base plate.

2240<2080>

230<200>

1800<1400>

d2

ST

175
<160>

4-M12

g2

700<550>

d1

SH

g1

625

DH

8-k2

(Remark)

FA

450<410>

630<560>

225<210> 350<320> 350<320> 350<320> 350<320> 275<230>

670<600>

d1

ST

(Remark)

FA

SH

350

700

DH

g1

6-foundation bolt(M16)
400<350>

625<500>

d2

AD

1900<1760>
L

AD
630 <560>

6-foundation bolt(M16)

(Remark)
Prepare pump maintenance space behind
electric motor, not install electric cable

390 <385>

700<1250>

670 <600>

450<445>

700

215 <210> 350<320> 350<320> 350<320> 350<320> 350<320> 275<270>

2240<2080>

5 pumps rotary

Dimension table
Unit
bore

suction
bore

mm

mm

80

32

100

125

150

6 pumps rotary

80

100

125

150

40

50

65

32

40

50

65

(Remark)
Prepare pump maintenance space behind
electric motor, not install electric cable

There are holes also for power supply cable(with rubber bush) below 3.7kw models.
is less than 3.7kW models. (is 65mm-3.7kW model. Foundation bolts are optional accessory.

type
KF2-32R5-0.75G
KF2-32R5-1.1G
KF2-32R5-1.9G
KF2-40R5-1.5G
KF2-40R5-2.2G
KF2-40R5-3.7G
KF2-40R5-5.5G
KF2-50R5-2.2G
KF2-50R5-3.7G
KF2-50R5-5.5G
KF2-50R5-7.5G
KF2-65R5-3.7G
KF2-65R5-5.5G
KF2-65R5-7.5G
KF2-32R6-0.75G
KF2-32R6-1.1G
KF2-32R6-1.9G
KF2-40R6-1.5G
KF2-40R6-2.2G
KF2-40R6-3.7G
KF2-40R6-5.5G
KF2-50R6-2.2G
KF2-50R6-3.7G
KF2-50R6-5.5G
KF2-50R6-7.5G
KF2-65R6-3.7G
KF2-65R6-5.5G
KF2-65R6-7.5G

L is omitted in case L600.


shows reverse direction to the drawing

Motor
kW
0.75
1.1
1.9
1.5
2.2
3.7
5.5
2.2
3.7
5.5
7.5
3.7
5.5
7.5
0.75
1.1
1.9
1.5
2.2
3.7
5.5
2.2
3.7
5.5
7.5
3.7
5.5
7.5

Combinations
SH
178
178
178
178
178
178
228
178
178
228
228
228
248
248
178
178
178
178
178
178
228
178
178
228
228
228
248
248

DH
676
676
676
676
676
676
745
676
676
745
745
809
854
854
676
676
676
676
676
676
745
676
676
745
745
809
854
854

FA
23
7
7
35
7
7
15
35
7
15
15
8
8
8
23
7
7
35
7
7
15
35
7
15
15
8
8
8

Weight
L
611
611
611
611
689
613
613
691
691
689
689
689
611
611
611
611
689
613
613
691
691
689
689
689

AD
95
95
95
95
95
95
90
95
95
90
90
92
92
92
95
95
95
95
95
95
90
95
95
90
90
92
92
92

kg
313
361
391
358
397
429
660
403
445
675
784
571
720
824
368
424
460
420
467
504
788
472
520
808
936
672
855
986

Vibration Proof bed


PW-1751J341

PBKV-MBP90

PW-1751J341-1

PBKV-MBP94

PW-2101J311-1

PW-1751J341-2

PBKV-MBP90

PW-1751J341-1
PW-1751J341-2
PW-2101J311-1
PW-2101J311-2

PBKV-MBP94

PW-2101J311
PW-2101J311-1
PW-2101J311-2
PW-2101J301
PW-2101J301-1

PBKV-MBP91

PW-2101J301
PW-2101J301-1

PBKV-MBP95

PW-2301J171-1

PBKV-MBP91

PW-2101J301-1

PBKV-MBP95

PBKV-MBP95

PW-2301J171-1
PW-2301J171
PW-2301J171-1
PW-2301J171-2

14

Control Panel
ECSG3-R type

Inverter, DC reactor and Earth leakage circuit


breaker for each pump
Noise filter, double tank type inflow motorized valve circuit
Compatible twin reservoir (5-pole)
Backup functions for pressure transmitter trouble
and control PCB trouble

(PHOTO : 6 Pumps Rotary 3.7 kW Model)

Type
Operation method
Rated voltage

Noise Filter
(High Efficiency Noise Absorb)

Display Detail

Earth leakage circuit breaker


and DC Reactor

Operation display

Display Detail

Pressure/Voltage Power Source

Trouble alarms

No
1 Pump
Current/Electric power/Voltage/Hz

Main components

Installation place

Inverter
Heater Terminal

External no-voltage signal

Functions

15

Earth leakage circuit


breaker (with AL)
DC reactor
Noise filter
Inverter
Control PCB
Power supply
Operation
Discharge head
Power voltage, current, frequency
Cumulative operation time/No. of starts
Trouble
Pressure drop
Residual current
Pressure transmitter trouble
Full, water level dropping, empty
Water level control
Inflow motorized
(solenoid) valve control
Pump trouble
Inverter trouble
Malfunction preventing retry
Pressure transmitter trouble
Control PCB trouble
Buzzer
Operation
Trouble
Full
Water level dropping
Empty

ECSG3-R
Multiple pump control rotary (three to six pump operation)
3 phase 380440V (200V is also avaolable)
Indoors, altitude 1,000m or less, ambient
temperature 0 to 40, humidity 90% or less
Pump, control circuit, heater circuit,
inflow motorized valve circuit
For each pump
High efficiency noise absorption material incorporated
(for main circuit and control circuit)
For each pump
Control PCB, display PCB, water level PCB
Lamp
Lamp (for each pump)
Digital
Digital
Digital
Lamp (for each pump)
Lamp (trouble message)
Lamp (trouble message)
Lamp (trouble message)
Lamp
Twin reservoir type (5-pole)
Twin reservoir type(3-pole)
(Backup operation [overload,
locking, phase failure, short circuit])
(Backup operation)
(Refer to following table)
(Backup operation)
(Backup operation)
(With ON-OFF switch)
(group)
(Group and independent)

List of trouble messages (type KF2-R)

Display Part

Item
Overload
Locking, phase failure
Ground fault
Over/under voltage
Inverter heating
Pressure drop
Pressure transmitter trouble
Control PCB trouble

Inverter

Reset Switch

Back up
(substitutional)
operation

Operation Mode Select Switch

Lamp display Trouble message External output


Trouble

OL
Trouble

OC1 to 3
Trouble

OC1 to 3
Trouble

OV-LV
Trouble

OH1
Trouble

HdL
Trouble

PEd
Trouble

ECU

Retry

Backup opera-tion

If trouble occurs, a normal control PCB, inverter


and pump are automatically selected, and
operation is continued.

Lightning
measures Lightning surge protection are taken on the "Pumper KF2 and KF2R" as a standard. However, in special installation places such as
on mountain peaks or when the earth resistance is large, the
attenuation effect of the lightning surge absorber will drop, so earth
the earthing wire to one point with the shortest distance, and
always provide special Class 3 (Class C) earthing from this device.

For 380440V

R201

Power supply 380440VAC


50/60Hz
RST
TB1
MCBL

(R)

(E) (T)

ED

(R)
(S) NF02
(T) (E)

S201

(R)
(S)NF01
(T) (E)

ELB2
(AL2)

(PD)

(PD)

Heater circuit

H31

H12

H22

H32

Heater Heater Heater


110Wx2 110Wx2 110Wx2

M2
No.2 pump

M3
No.3 pump

Buzzer Empty
ON
Dry
OFF

Reset

Current
leakage

Run

Run

Run

Run

Trouble

Trouble

Trouble

Trouble

Stop

Stop

Stop

Stop

Stop

Stop

No.2

No.3

Relay
terminal
block

TB3

DCR6
(P)

Control
CPB1

M6

No.5 pump

TB2

Control
CPB2

Control
CPB3

Control
CPB1

Control
CPB4

Control
CPB2

Control
CPB3

Control
CPB4

No.6 pump

Sub-CPU
error

Run

No.1

(G)(R)(S)(T)
INV6 (P)
(P1)
(U)(V)(W)(G)

M5

No.4 pump

Trouble

Auto- Manual
matic

DCR5
(P)

Run

Auto- Manual
matic

(G)(R)(S)(T)
INV5 (P)
(P1)
(U)(V)(W)(G)

M4

Trouble

Auto- Manual
matic

DCR4
(P)

R201 S201

MCB10
R400 R400

Auto- Manual
matic

No.4

No.5

Auto- Manual
matic

No.1 Pump
Current/Electric power/Voltage/Hz

Pressure/Voltage power source

*2 Display Detail

*3 Display Detail

No.6

Display Detail

For 380440V

Connect to display
PCB 1
(26-pin flat cable)

Display PCB 1

FAN

Power Main CPU


supply error

FAN

Discharge pressure transmitter


error

Current
leakage

1 2
DC fan

SS3
DISP
Display PCB 1

Dry

TR1
200V-OUT

Run

Run

Run

Trouble

Trouble

Trouble
SW1 SW2 SW3
No.1

Independent

12V-IN

200V-OUT

INV2
1
8
No.2 inverter

SW8 Auto No.2


OFF 1 ON

Run output
terminal/no-voltage

COM2
PS1

FS2

FS1

Inflow motorize
valve/open

No.2 flow
sensor

Discharge side
pressure
transmitter

No.1

Switch

Level relay

Inverter control PCB 1

200V-IN

COM1

PS-IN
PS2
PS-OUT
Control
Control
Not
PCB 2
PCB 3
ConConnect
Connect
nected
to PS-IN
to PS-IN

Function

Close

Parallel

No.3

TR1

6
Fault output/reservoir water level
signal output terminal/no-voltage

LVS

X2 301 EXT
302

ELB1 AL1
Current
leakage 1

(04 specifications)
AUX

ELB2 AL2
Current
leakage 2

1
200VAC
R S

No.1 Run

No.2 Run

* Prepare a separate
power supply for
380440V.

A
5

No.3 Run

Common 1

Connection for power ON


(open)

A
6

A
7

A
8

A
9

A A
10 11

Connection for power ON


(closed)
R T

R T
Open

MV MV MV
0 11 21
MV1 MV2
Open

No.2 Inflow motorized


valve

No.1 Inflow motorized


valve

MV2

A
4

Common 2

A
3

Close

A
2

Open

MVMVMVMVMV
0 11 12 21 22

A
1

Open/Close

MV1
200VAC power output

Connect
to ELB10

Open

Alternate

No.2

INV1
8
1
No.1 inverter

No.1 No.2

Manual Stop Auto- Manual Stop Auto- Manual Stop Automatic


matic
matic

No.1

33 F
0 0 1 1WXFC
BC2 1D3MM

OPT
7
1
Expansion output

OFF

12V-IN

Control PCB 2
Connect to
COM1

Control PCB 3
Connect to
COM1

33 F
0 0 1 1WXFC
BC2 1D3MM

Control PCB 2
Connect to SS3

Full

Buzzer Empty
ON

Reset

Connect
to MCB10

16

Automatic

No.1 No.2
Inflow solenoid valve

MV MV MV
0 12 22
MV1 MV2

TB4

E E E E E
3 12 11 15 14

E E
32 31

E E E E E
3 22 21 25 24

E E
42 41

Empty

Full

Main CPU Discharge preserror


sure transmitter
error

(G)(R)(S)(T)
INV4 (P)
(P1)
(U)(V)(W)(G)

Dry

No.1 pump

DCR3
(P)

Full

M1

(G)(R)(S)(T)
INV3 (P)
(P1)
(U)(V)(W)(G)

(PD)

No.3 Fault

DCR2

(PD)

R1
S1

Control circuit

ELB11

R200 S200
Relay
terminal
block

Close

(G)(R)(S)(T)
INV2 (P)
(P1)
(U)(V)(W)(G)

(PD)

ELB6
(AL6)
Connect to
middle plate

No.2 Fault

DCR1
(P)

ELB5
(AL5)

Close

(G)(R)(S)(T)
INV1 (P)
(P1)
(U)(V)(W)(G)

ELB4
(AL4)

ELB3
(AL3)

No.1 Fault

ELB1
(AL1)

Manual

H21

For 400V
Control circuit

R1

ELB10

Current
leakage

H11

TB0
S1

Power
supply

TH22

Class C
earthing

(R)
(S) LA
(T) (E)

R1S1 T1

Thermostat
ON at temperature drop

TH12

ED

NF1

TH21

Thermostat
ON at temperature drop

(1)
(2)LA2
(3) (E)

NF02(S)

Power supply 200VAC


50/60Hz
RST
TB1

TB3

TH11

(1)
(2) LA1
(3)

Control Panel / Control Panel Wiring Diagram

Control Panel Wiring Diagram

Full
ON
Empty
OFF
Dry
No.1 reservoir

Close
Open

Full
Close
ON
Open
Empty
OFF
solenoid valve
Dry Inflow
Inflow motorized valve
No.2 reservoir

No.1 No.2
Inflow solenoid valve

*2 Using inflow solenoid valve

*3 Short-circuit wires (red) are connected across E3-E11-E15.


Remove these short-circuit wires when using the electrode rod.

KF2-R

Control Panel Wiring Diagram

Connect to ELB10
(For 380440V : Connect to MCB10)

Connect to ELB10
(For 380440V : Connect to MCB10)

916

916

Power supply LED

Power supply LED


Current
leakage 3

No.3 inverter

Connect to PS-IN
Control PCB 1

No.6 inverter

Not connected
1 1 3 3
3 1 2 0 0

Conrtol PCB 1
Connect to COM2

No.3 flow sensor

Not connected
1 1 3 3
3 1 2 0 0

17

Connect to SS3
Control PCB 1

Connect to PS-IN
Control PCB 1

Inverter Control PCB 4

No.3 flow sensor

Connect to SS3
Control PCB 1

Current
leakage 3

Inverter Control PCB 2

Conrtol PCB 1
Connect to COM2

For 380440V

916

12

Connect to display
PCB 2
(26-pin flat cable)

Display PCB 2

3
200

916

Current leakage
456

Display PCB 2

1
7
Expansion output

Run

Run

Run

Trouble

Trouble

Trouble

1
1 2 3

Independent
Alternate
Parallel

12

Open
Close

Auto
2
8
1

3
200
200

No.4 inverter

Manual Stop Auto- Manual Stop Auto- Manual Stop Automatic


matic
matic

2
1
8
No.5 inverter

2
Control
Control
Not
PCB 4
PCB 1
ConConnect
Connect
nected
to PS-IN
to PS-IN

Inflow motorized
valve/open

1
Not
Connected

1
No.4 flow
sensor

No.5 flow
sensor

Function
Switch

Inverter control PCB 3

Run outputterminal/no-voltage Fault output/reservoir water level signal output terminal/no-voltage

Always
sgortcirduited

Not
Connected

4
Current
leakage 4
2

5
Current
leakage 5

No.6 Fault

No.5 Fault

No.4 Fault

No.6 Run

A A A A A A A
25 26 27 28 29 30 31

No.5 Run

A A A A
21 22 23 24
No.4 Run

200VAC power supply output


(only for 200V)

Common 4

200
R S

Common 3

Connect
to 10

Control PCB 1 Control PCB 4


Connect to
Connect to
COM1
COM1

Sub-CPU
error

1 2
DC fan

Connect
to MCB10

C
33
1 1
2 13

33
Control PCB 4 0 0 1 1
Connect to SS3 2 13

A B C D shows connecting part for each wiring diagram

Series Product

KFH2

Application
Exclusive owater supply automatic pressure unit : Max 85
Booster for water heater, solar water heater,etc.

Feature
Precision stainless steel casting pump unit
Constant pressure hot water supply at estimated terminal outlet : Energy saving 40% Max.
Substantial standard equipments : Inverter for each pump, residual current circuit breaker
High reliability : TEFC motor,surge killer,noise filter,DC reactor
High power factor : Power factor more than 85.5%
Unified domestic standard : Cmmon specification in 50Hz and 60Hz

Standard specifications

Components parts

Constant pressure at estimated terminal outlet using frequency


control (constant discharge pressure also possible)
Operation method Alternate or alternate/parallel of 2 pumps
Indoors (ambient temperature 0 to 40C, humidity 90% or less,
Installation place
altitude 1,000m or less)
Liquid
Clean water, 0 to 85C
Stainless steel multi-stage turbine pump
Pump (material)
(impeller : SCS13, shaft: water contact section SUS304,
casing : SCS13)
TEFC indoor type
Motor
No. of poles: 2 poles (max. frequency during automatic operation: 60 Hz)
Suction conditions Positive suction (0 to 5m)
Power supply
3 phase 380440V (200V is also avaolable)
Phase flange shape JIS 10 K thin type
Paint color
Control panel: gray (5Y7/1), accumulator: gray (10Y5.5/0.5),
(Munsell No.)
others: gray (2.5PB5.1/0.8)
Control method

Pressure transmitter

Check valve

Stainless steel shockless type

Accumulator

PTD3-2AS

Others

Companion flange, base

With BK Type vibration proof bed

Optional accessory

18

Pump cover
Water level sensor
Discharge connecting pipe for other direction
Vibration isolator
Foot valve

80

60

KFH2-40A3.7

KFH2-40P3.7

KFH2-40P2.2

50

40

ECSGA3-AP

Flow sensor

Special specification

Selection chart

Total
head
(m)

Control panel

KFH2-40A2.2

KFH2-50P3.7

KFH2-50A3.7

30

KFH2-40A1.5
20

KFH2-50A2.2
15
0.1

0.2

0.3

KFH2-40P1.5

0.4

0.5

KFH2-50P2.2

0.6

0.8

1.0

Flow rate (m3/min)

40
40
50
50

40

65

50

Alternate

mm

Alternate/Parallel

mm

Operation

Selection table (Pump stop flow rate10 l/min)


sidcharge suction
bore
bore

Model
KFH2-40A1.5
KFH2-40A2.2
KFH2-40A3.7
KFH2-50A2.2
KFH2-50A3.7
KFH2-40P1.5
KFH2-40P2.2
KFH2-40P3.7
KFH2-50P2.2
KFH2-50P3.7

Motor
Standard specifications
(Maximum number
of operation units) Flow rate Total head Starting pressure
kW
1.5
2.2
3.7
2.2
3.7
1.5 x 2
2.2 x 2
3.7 x 2
2.2 x 2
3.7 x 2

(Note) When using flushing valve, select 2.2kW or more.

Please refer to KF2-A-P (P56) about control panel.


Dimension drawing : Please inquire us.

m3/min
0.14
0.14
0.16
0.225
0.265
0.28
0.28
0.32
0.45
0.53

Control Panel Wiring Diagram / KFH2

Stainless Steel Hot Water Pressure Unit

m
32
48
65
32
48
32
48
65
32
48

MPa{kgf/cm2 }
2.5
0.25
3.9
0.38
5.5
0.54
2.5
0.25
3.9
0.38
2.5
0.25
3.9
0.38
5.5
0.54
2.5
0.25
3.9
0.38

Set head
adjustment
range

Accumulator
charged
pressure

Sound
*

MPa{kgf/cm2 }
0.121.2
0.202.0
0.313.2
0.121.2
0.202.0
0.121.2
0.202.0
0.313.2
0.121.2
0.202.0

dBA
5052
5053
5558
5356
5557
5055
5056
5561
5359
5560

2032
3048
4465
2032
3048
2032
3048
4465
2032
3048

Vibration
proof
bed

QGP-38
or
PJ--935A
or
RK-960
or
BK-970

(*1) The noise level is the maximum value given in the specifications.

SAFETY
PRECAUTIONS

Always read the instruction manual carefully before starting to ensure sorrect use.
Select a product which matches the application. Using the pump in an incorrect application could
lead to faults.
Always follow the Electrical Facility Technology Standards and in-house standards and safety
and accurately select and complete electrical wiring work.
Always ground the unit and install the dedicated residual current circuit breaker. There is a risk of
failure or electric shock in the event of a failure or residual current. Consult your dealer for
information on grounding the unit.

The specifications and shapes, etc., may be changed for improvement, etc. Unauthorized reproduction of this document is prohibited.
Distributor

KAWAMOTO PUMP MFG. CO.,LTD.


Overseas Marketing Section
11-39, Ohsu 4-chome, Naka-ku, Nagoya 460-8650, JAPAM
TEL. +81-52-251-7173. FAX. +81-52-241-6151
E-mail : kawamotobo@aol.com
http://www.kawamoto.co.jp

Name KF2-APTR
No.

0810

/E