Introduction
Quality check is an activity which needs to be conducted after site
installation is completed.
Quality Check is done to verify that the installed site meets the
installation guidelines or not.
Table Of Contents
Installation Quality Check List
RF Antenna
RRU - Remote Radio Unit
GPS Antenna
CDU - Cabinet Digital Unit
Other Important Quality Checks
40-90 mm
14 mm
45
45
23
23
.
GPS Antenna
RRU
GPS Antenna
RF Antenna
RRU
RF Antenna
14 mm
* Torque : 239.7 ~ 270.3 kgf.cm
(23.5~26.5 Nm)
Azimuth Measurement-Compass
Tilt Measurement: Tilt Meter
2013 Samsung Electronics
RF Antenna
Min. radius
of curvature
RET Connector
RF cable type
Min. Radius
Manufacturer
1/2
125 mm
LS
5) Cable Labeling
Labeling should be done according to guideline (Alpha-Blue,Beta-Red,Gamma-Green)
Alpha Sector
Sector
Alpha
Beta
Gamma
Beta Sector
Gamma Sector
RF Cable
Color Code
Path#0
Path#1
Path#2
Path#3
Path#0
Path#1
Path#2
Path#3
Path#0
Path#1
Path#2
Path#3
Check distance between RRU bottom & the lower cable tie with steel ruler. It should
be minimum 80mm
10
Antenna side
RRH side
11
If found a Gap, turn the cap clockwise tightly with finger and mark up the permanent marker .
12
13
14
15
Bakelite(5T)
M830L Hex. Bolt
Unit Mounting
Bracket Upper furrow
Bakelite(5T)
M8 Insulation Bushing
M8 Plain Washer
M8 Spring Washer
M8 x 30L Hex. Bolt
16
[Stud Bolt]
[U[U-Bolt]
17
4) Cable Status
CPRI, Power, RET cable should be terminated on desired port with correct polarity
Check all cable for any damage and sharp bend.
Check the routing of all the cables is done properly.
10mm
Power Gland Nut
18
6) RRU Grounding
Grounding should be done using F-GV 6.0 x 1C cable, 2Hole Terminal.
Check cable for any damage and sharp bend.
Check the routing of the cable is done properly.
Check whether grounding cable lugs are covered with the green heat shrink tube.
SEMS(M6x12L, 2EA)
RRU
Ground
Cable
CPRI for
Pressure Terminal
RRU for
Pressure Terminal
Cable Tie
CPRI Ground Cable
RRU Ground Cable
[R[R-03] ~ [R[R-11] Connection of
Ground Cable
19
20
21
25
TMC
25
TMC
30
TMC
22
23
24
25
45
45
23
GPS Antenna
RRU
23
GPS Antenna
RF Antenna
RRU
RF Antenna
26
Antenna
[D[D-11] ~ [D19]
[D[D-27] GPS
Cable(CNT-400)
[D[D-28] GPS
Arrestor
27
2) GPS Connectorization
CHECK POINT
#1 Check both connector should be made as guideline
#2 Crimp ring should crimp with hexagonal crimping tool two times
28
29
30
31
Dummy Panels
Unused Ports
32
3) CDU Grounding
CHECK POINTS :
#1 Ground cable shall be securely fastened on the back of CDU
#2 Grounding should be done using F-GV 4.0 x 1C cable, 2Hole Terminal.
#3 Check cable for any damage and sharp bend.
#4 Check the routing of the cable is done properly.
#5Check whether grounding cable lugs are covered with the green heat shrink tube.
33
4) Cable status
Power cable connector and ground cable inspection
CHECK POINT
#1 Power connector shall be securely connected to receptacle
#2 Ground cable shall be securely fastened
#3 Check all cable for any damage and sharp bend.
#4Check the routing of all the cables is done properly.
34
5) SFP module
Check SFP module Single mode (Color Blue)
If Black multi-mode SFP is found, please return it to Samsung contact person after
replacing it with Blue single-mode SFP
35
36
1) Roxtec
Check all cable entries in roxtec as per guideline
Boots should be fixed properly without any gap
37
38
3)MCB
Mention the MCB rating
Ensure the labeling
MCB screw should be tighten on the copper not on insulation cover
Cross check the color coding of Power cable: +VE Black & -VE is White
CDU RRU-0
RRU-1 RRU-2
39
4)Cable Tray
Open cable tray cap and check cable routing at key points and cable should not be
crossed or twisted
5) Equipment Status
Check for any damages(scratches, dents) on all elements.
40
Quality Checklist
SITE CHECK LIST
Site ID
Site Name
Ite m
Date
Solpar
Result
(OK/NOK
)
Area
Auditor
Remarks
Weig
ht
Description
1) Antenna Fixing
2) Antenna Position
5) Cable Labeling
2.5
7.5
2. RRH Part
1) RRH Bracket Fixing
2) Bolt,Nut,Washer,Bushing,
Bakelite status
4) Cable Status
2.5
7.5
7) RRH Grounding
___V
25
2) GPS Arrester
3) Cable status
41
Microsoft Office
Word 97 - 2003 Document
43
Commissioning of eNodeB
(Including ATP11_B)
45
Pre-requisites of Commissioning
RS232 C Cable or Ethernet Cable (Debug Cable)
Laptop with serial or Ethernet Port
CLI Login details
TeraTerm Application/other Telnet application software installed
on Laptop
Site Parameter details like IP of LSM-R, IP of eNodeB, IP of
CSS- Gateway etc.
4G Dongle for data call test (In case of Backhaul availability)
46
Login Options
1. Serial Port(RS232) interface
2. Ethernet(RJ45) Interface (Recommended)
47
48
49
50
51
52
53
192.168.32.28
Subnet Mask:
255.255.255.0
Default Gateway:
192.168.32.27
54
55
56
Steps of Commissioning
Steps:
1) Login to UAMA board
2)Setting eNB environment parameters
a) Login as Super User mode
b) Check the original eNB environment parameters
c) Delete/Add eNB environment parameters
d) Confirm parameter settings
57
58
Password: ********
59
bootcmd=bootoctbflag
AUTH=yes
BOOTMODE=static
RS_LOGIN=sysuser
RS_PASSWD=syslte123
SECU_CONN=yes
SECU_PASSWD=yes
adminstate=0
RS_IP=100.127.129.84
BOOTPORT=PORT_0_0_0
PORT_0_0_0_IPVER=4
PORT_0_0_0_IPV4_NM=30
PORT_0_0_0_IPV4_IP=100.127.132.1
PORT_0_0_0_IPV4_GW=100.127.132.2
NE_ID=16
IPV6_ENABLE=1
PORT_0_0_0_VLANID=103
60
-p [Parameter Name]
61
-p [Parameter Name]
root@UAMA:/root>
root@UAMA:/root> delenv -p NE_ID
Name = NE_ID
Value =
root@UAMA:/root> getenv -a
[Env Information]
bootdelay=1
baudrate=115200
pci_console_active=yes
pci_console_count=1
pci_console_size=2097152
~~
RS_IP=2405:201:fffb:0:1::52
BOOTPORT=PORT_0_0_2
PORT_0_0_2_IPVER=6
PORT_0_0_2_IPV6_NM=112
PORT_0_0_2_IPV6_GW= 4fa1:f00d:1234:5678:9abc:def1:aaaa:3
PORT_0_0_2_IPV6_IP= 4fa1:f00d:1234:5678:9abc:def1:aaaa:25
IPV6_ENABLE=1
__BOOTUP_FLAG__=000000020e
62
-p [Parameter Name]
63
setenv -p bootdelay 1
setenv -p baudrate 115200
setenv -p pci_console_active yes
setenv -p pci_console_count 1
setenv -p pci_console_size 2097152
setenv -p stdin pci
setenv -p stdout pci
setenv -p stderr pci
setenv -p ethact octeth0
setenv -p bootcmd bootoctbflag
setenv -p AUTH yes
setenv -p BOOTMODE static
setenv -p RS_LOGIN sysuser
setenv -p RS_PASSWD syslte123
setenv -p SECU_CONN yes
setenv -p SECU_PASSWD yes
setenv -p adminstate 0
setenv p RS_IP 2405:201:fffb:0:1::52
setenv p BOOTPORT PORT_0_0_2
setenv p PORT_0_0_2_IPVER 6
setenv p PORT_0_0_2_IPV6_NM 112
setenv p PORT_0_0_2_IPV6_GW 4fa1:f00d:1234:5678:9abc:def1:aaaa:3
setenv p PORT_0_0_2_IPV6_IP 4fa1:f00d:1234:5678:9abc:def1:aaaa:25
setenv p NE_ID 26405
Press enter after this
setenv p IPV6_ENABLE 1
setenv p PORT_0_0_2_VLANID 103
64
root@UAMA:/root>
root@UAMA:/root> setenv -p bootdelay 1
Name = bootdelay
Value = 1
root@UAMA:/root> setenv -p baudrate 115200
Name = baudrate
Value = 115200
root@UAMA:/root> setenv -p pci_console_active yes
Name = pci_console_active
Value = yes
root@UAMA:/root> setenv -p pci_console_count 1
Name = pci_console_count
Value = 1
root@UAMA:/root> setenv -p pci_console_size 2097152
Name = pci_console_size
Value = 2097152
root@UAMA:/root> setenv -p stdin pci
Name = stdin
Value = pci
root@UAMA:/root> setenv -p stdout pci
Name = stdout
Value = pci
root@UAMA:/root> setenv -p stderr pci
Name = stderr
Value = pci
root@UAMA:/root> setenv -p ethact octeth0
Name = ethact
Value = octeth0
65
67
-p [Parameter Name]
LSM server IP
Booting port
Using IP Version
OAM IP Net-mask
OAM Gateway IP
eNB OAM IP
eNB ID
IPV6 Enable=1, Disable=0
OAM VLAN ID
68
root@UAMA:/root> getenv -a
[Env Information]
bootdelay=1
baudrate=115200
pci_console_active=yes
pci_console_count=1
pci_console_size=2097152
stdin=pci
stdout=pci
stderr=pci
ethact=octeth0
bootcmd=bootoctbflag
AUTH=yes
BOOTMODE=static
RS_LOGIN=sysuser
RS_PASSWD=syslte123
SECU_CONN=yes
SECU_PASSWD=yes
adminstate=0
RS_IP=2405:201:fffb:0:1::52
BOOTPORT=PORT_0_0_2
PORT_0_0_2_IPVER=6
PORT_0_0_2_IPV6_NM=112
PORT_0_0_2_IPV6_GW=4fa1:f00d:1234:5678:9abc:def1:aaaa:3
PORT_0_0_2_IPV6_IP=4fa1:f00d:1234:5678:9abc:def1:aaaa:25
NE_ID=26405
IPV6_ENABLE=1
PORT_0_0_2_VLANID=103
__BOOTUP_FLAG__=000000020e
69
There are lots of memories in UAMA unit in the progress of factory test; it can be affected for
software loading. Therefore, it is recommended to remove all shred memory under /mnt
directory in UAMA unit.
70
71
After eNB restart, check the connectivity between eNB and LSM by ping command.
If there is issue with connectivity, check whether the eNB IP and route, VLAN configuration is
correct, else coordinate with LSM-R Engineer.
72
Steps:
5) Check System Status ( Hardware Alarms)-In normal condition
In normal condition
2013 Samsung Electronics
73
Steps:
5) Check System Status ( Hardware Alarms)-In abnormal condition
Action to be taken:
Report the current situation to LSM-R team
Troubleshoot the problem, coordinate with LSM-R Team
Dont leave the site till alarm clear
74
ATP11B
Introduction
ATP11_B is conducted after site Integration
Test Tools & Method of procedure will be provided by
RJIL.
Tools needed:
Laptop
UE (User Equipment)
Application to perform test (test tool)
76
ATP11_B- Items
Microsoft Office
Word Document
77
Gamsahapnida
Thank You
Copyright and Confidentiality
Copyright 2013, SAMSUNG Electronics Co., Ltd. SAMSUNG Electronics reserves the right to make changes to the specifications of
the products detailed in this document at any time without notice and obligation to notify any person of such changes. Information
in this document is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated,
transcribed or duplicated by any form without the prior written consent of SAMSUNG Electronics.