GENERAL SPECIFICATION
3.1
Sec3-SP (2002)
GENERAL
a.
b.
c.
d.
Stainless steel (SS 304) drain trays with drainage connections shall
be provided to the underside of all sanitary, soil, waste and vent
pipes which are directly above kitchen, dining and any food
preparation areas.
e.
f.
3.1
MEINHARDT
SECTION 3
SANITARY AND PLUMBING INSTALLATION
GENERAL SPECIFICATION
3.2
PIPING INSTALLATION
3.2.1
b.
3.2.2
CONNECTION
PIPE SIZE
75 mm (WC Compartment)
75 mm (Shower)
75 mm (WC Compartment)
75 mm (Shower)
75 mm (15 m maximum)
100 mm (30 m maximum)
150 mm (over 30 m)
Pipe Gradient
a.
Sec3-SP (2002)
Minimum pipe sizes for all horizontal sanitary and waste piping
shall be as shown on drawings or otherwise as indicated below:
GRADIENT
32 mm to 80 mm
1:40
100 mm
1:60
150 mm
1:80
1:100
b.
c.
All pipe gradient shall also comply with the requirements of ENV.
3.2
MEINHARDT
SECTION 3
SANITARY AND PLUMBING INSTALLATION
GENERAL SPECIFICATION
3.2.3
3.2.4
Sec3-SP (2002)
Pipe Support
a.
b.
c.
d.
b.
c.
3.3
MEINHARDT
SECTION 3
SANITARY AND PLUMBING INSTALLATION
GENERAL SPECIFICATION
3.2.5
3.2.6
d.
The low end of all vertical lines of vent pipes shall be connected full
size at not less than 45 degree angle to the horizontal. All offsets
shall be at a grade of not less than 45 degree angle to the
horizontal.
e.
Waste pipes need not be vented except where the pipe length
exceeds 2m inclined length and/or 5.5 m in vertical length provided
that there is only one fixture connected to the waste pipe. Where
there is more than one fixture or where the water seal is reduced, a
vent pipe shall be supplied to the fixture of traps.
The top end of each discharge or vent stack shall project not less
than 450 mm above the eaves of a sloping roof or 150 mm above a
flat roof without a parapet, or in the case of a flat roof with a
parapet to the height of parapet above the roof. If the roof is used
for any purpose other than as a covering to the building, the
discharge or vent stack shall be extended at least 2.5 m above the
roof level. Proper lead over-flashing has been completed.
b.
The top end of a discharge or vent stack above the roof shall be at
least 3 m away from any window or opening of adjoining buildings
in the horizontal direction.
c.
The top end of a discharge or vent stack above the roof shall be
fitted with galvanised wire dome gratings on to the spigot top-most
end of the pipes.
d.
Sec3-SP (2002)
3.4
MEINHARDT
SECTION 3
SANITARY AND PLUMBING INSTALLATION
GENERAL SPECIFICATION
3.3
3.4
Sec3-SP (2002)
TRAPS
a.
b.
c.
d.
e.
b.
c.
The grating or cover shall be installed and located such that they
blend in with the surrounding ground levels and do not pose a
hazard in causing trip, etc.
3.5
MEINHARDT