Professional Documents
Culture Documents
User's Guide
Copyright
Copyright 2002-2012 Intergraph Corporation. All Rights Reserved.
Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement;
contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret
law, and international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph
Corporation.
Terms of Use
Use of this software product is subject to the End User License Agreement ("EULA") delivered with this software product unless the
licensee has a valid signed license for this software product with Intergraph Corporation. If the licensee has a valid signed license
for this software product with Intergraph Corporation, the valid signed license shall take precedence and govern the use of this
software product. Subject to the terms contained within the applicable license agreement, Intergraph Corporation gives licensee
permission to print a reasonable number of copies of the documentation as defined in the applicable license agreement and
delivered with the software product for licensee's internal, non-commercial use. The documentation may not be printed for resale or
redistribution.
Trademarks
Intergraph, the Intergraph logo, PDS, SmartPlant, SmartMarine, FrameWorks, I-Convert, I-Export, I-Sketch, IntelliShip, INtools,
ISOGEN, MARIAN, SmartSketch, SPOOLGEN, SupportManager, and SupportModeler are trademarks or registered trademarks of
Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered
trademarks of Microsoft Corporation. MicroStation is a registered trademark of Bentley Systems, Inc. Other brands and product
names are trademarks of their respective owners.
Contents
SmartPlant Electrical Overview ............................................................................................................... 23
Working in a Multi-User Environment ................................................................................................... 24
Getting Started with SmartPlant Electrical ............................................................................................. 25
Connecting to a Plant Group ................................................................................................................. 25
Changing Plant Group Hierarchy Names ....................................................................................... 26
Apply Plant Group Hierarchy Name Changes ................................................................................ 26
Create a Plant Using Reference Data from an Existing Plant .............................................................. 27
Customizing Preferences ......................................................................................................................... 29
Customize General Preferences ........................................................................................................... 29
Customize Preferences for SLD Generation ........................................................................................ 30
Customize All Feeder Load Summary Report Preferences .................................................................. 31
Customize Delete Loads Preferences .................................................................................................. 32
Customize Delete Load Preferences for a Specific Item ...................................................................... 32
Troubleshooting Errors and Rule Inconsistencies ................................................................................ 33
Generating Error Log Files .................................................................................................................... 33
Activate Log File Generation ................................................................................................................. 33
Generate Error Log Files ...................................................................................................................... 34
Troubleshooting Rule Inconsistencies .................................................................................................. 34
Fix Inconsistencies ................................................................................................................................ 35
Troubleshoot Rule Inconsistencies ....................................................................................................... 35
Operator Descriptions and Rule Examples ........................................................................................... 35
Working with Reference Data ................................................................................................................... 37
Reference Data Explorer ...................................................................................................................... 37
Select a Set of Item Tags in the Reference Data Explorer ............................................................ 38
Shipped Reference Data ....................................................................................................................... 39
Create a Reference Item ....................................................................................................................... 40
Copy a Reference Item to the Electrical Index ..................................................................................... 40
Create a Typical Electrical Motor .......................................................................................................... 41
Create Typical I/O Signals .................................................................................................................... 42
Creating Typical Panels ........................................................................................................................ 42
Create a Typical Cabinet ................................................................................................................ 42
Create a Typical Control Station .................................................................................................... 43
Edit Typical Control Station Common Properties ........................................................................... 43
Create a Typical Local Panel ......................................................................................................... 43
Create a Typical Junction Box ........................................................................................................ 43
Create a Typical Circuit ......................................................................................................................... 44
Copy Components to a Typical Circuit ........................................................................................... 44
Copy from Typical Circuit Components .......................................................................................... 45
Create a Profile ..................................................................................................................................... 45
Edit Profile Common Properties ..................................................................................................... 46
Working with Typical Cable Block Diagrams ........................................................................................ 47
Create a Typical Cable Block Diagram .......................................................................................... 48
Contents
Using Reference Control Stations, Typical Circuits, and Reference Instruments in
Typical CBDs .................................................................................................................................. 49
Using Reference Motors with Space Heaters in Typical CBDs...................................................... 49
Using Reference Junction Boxes and Local Panels in Typical CBDs ............................................ 49
Make Non-Power Flow Associations in a Typical CBD .................................................................. 50
Hide Association Connectors ......................................................................................................... 51
Create Typical Schematic Blocks ......................................................................................................... 51
Edit Typical Schematic Block Common Properties ........................................................................ 52
Create a Typical Schematic .................................................................................................................. 53
Edit Typical Schematic Common Properties .................................................................................. 53
Create a Multi-Sheet Typical Schematic ........................................................................................ 55
Working with Lookup Tables ................................................................................................................. 56
Create Lookup Tables .................................................................................................................... 56
Edit Lookup Tables ......................................................................................................................... 56
Lookup Table Structure Example ................................................................................................... 58
Lookup Table Data Example .......................................................................................................... 58
Enable Additional Regional Standard Lookup Tables .................................................................... 59
Associate and Apply a Lookup Table to a Circuit Internal Component .......................................... 59
Automate the Sizing of Circuit Internal Components Based on Load Data ................................... 60
Reference Electrical Engineer .............................................................................................................. 61
Copy Power Network Structures from Another Plant ..................................................................... 62
Rules Governing the Copying of Power Network Structures to the Electrical
Engineer ......................................................................................................................................... 63
Rules for Copying Branches with Auxiliary Contacts ..................................................................... 64
Creating and Modifying Equipment ......................................................................................................... 65
Using Naming Conventions .................................................................................................................. 65
Electrical Index ...................................................................................................................................... 66
Customizing Folders ....................................................................................................................... 67
Select a Set of Item Tags in the Electrical Index ............................................................................ 69
Customize the Sort Sequence of Items in Tree Folders ................................................................ 70
Show Related Items in a New Electrical Index Window ................................................................. 70
Move an Item to Another Plant Group ............................................................................................ 71
Properties Window ................................................................................................................................ 72
Turn the Display of the Properties Window On or Off .................................................................... 72
Use Select Set Mode in the Properties Window ............................................................................ 72
Review and Edit Item Properties .................................................................................................... 73
Properties Window Toolbar ............................................................................................................ 73
Copy Bulk Properties ...................................................................................................................... 74
Paste Bulk Properties ..................................................................................................................... 75
Customizing Data Display in the Properties Window ..................................................................... 75
Customize Data Display in the Properties Window ........................................................................ 75
Show Brief Properties ..................................................................................................................... 76
Display Null Values in the Properties Window ............................................................................... 76
Add a Text Box for UDFs in the Properties Window ...................................................................... 76
Create a New Item in the Electrical Index ............................................................................................. 77
Create a Project Item Based on a Reference Item ............................................................................... 77
Edit Item Properties .............................................................................................................................. 78
Duplicate an Item .................................................................................................................................. 78
Rename an Item.................................................................................................................................... 79
Delete an Item ....................................................................................................................................... 79
Working with Loads ............................................................................................................................... 81
Create Load Items in Batch Mode .................................................................................................. 82
Contents
Electrical Motors ............................................................................................................................. 82
Create Static Electrical Equipment ................................................................................................. 85
Create Miscellaneous Electrical Equipment ................................................................................... 87
Managing Space Heaters and Their Power Supplies ........................................................................... 89
Suggested Workflows for Space Heaters and Auxiliary Contacts ................................................. 90
Create a Space Heater ................................................................................................................... 97
Show Space Heaters Next to the Associated Motors in SLDs ....................................................... 97
Use Symbol Assemblies for Space Heaters with Motors in SLDs ................................................. 98
Show Auxiliary Contacts Next to Disconnect Equipment in SLDs ................................................. 98
Use Symbol Assemblies for Disconnect Equipment with Auxiliary Contacts in SLDs
........................................................................................................................................................ 99
Create a Generator ............................................................................................................................... 99
Define a Neutral Earthing Connection for Generators ................................................................. 100
Create an Offsite Power Supply.......................................................................................................... 100
Create a Battery Bank ......................................................................................................................... 101
Converting Equipment ........................................................................................................................ 101
Create Converting Equipment ...................................................................................................... 102
Create a Transformer ................................................................................................................... 102
Define Transformer Connections ................................................................................................. 103
Define Transformer Tapping ........................................................................................................ 104
Define Converting Equipment as Consumers .............................................................................. 104
Power Distribution Equipment ............................................................................................................... 105
Power Distribution Boards and Buses ................................................................................................ 105
Create a Power Distribution Board (PDB) .................................................................................... 106
Create a Bus ................................................................................................................................. 106
Create a Freestanding Bus .......................................................................................................... 107
Delete a Power Distribution Board or a PDB Internal Item .......................................................... 107
Create Disconnect Electrical Equipment ............................................................................................ 108
Create an Auxiliary Contact .......................................................................................................... 109
Metering Equipment ............................................................................................................................ 110
Create Measuring Transformers .................................................................................................. 110
Create Meters ............................................................................................................................... 111
Create Relay Functions ................................................................................................................ 112
Create Protection Relays.............................................................................................................. 112
Copy Metering Equipment ............................................................................................................ 114
Designing Power Distribution Boards ................................................................................................. 114
Design a Power Distribution Board Structure ............................................................................... 115
Design a Power Distribution Board Layout................................................................................... 116
Open a PDB Layout Design for a Selected PDB ......................................................................... 117
Create a Cell ................................................................................................................................. 118
Automate Cell Size Definition ....................................................................................................... 119
Using Dual Source Power Supplies .................................................................................................... 119
Associate a Dual Power Supply with an Equipment Item ............................................................ 120
Change an Alternative Power Supply of an Equipment Item ....................................................... 120
Dissociate an Alternative Power Supply from an Equipment Item ............................................... 121
Using Transfer Switches ..................................................................................................................... 121
Create a Transfer Switch .............................................................................................................. 121
Generate an SLD for a Transfer Switch ....................................................................................... 122
Working with Circuits .......................................................................................................................... 122
Create a Circuit ............................................................................................................................. 122
Copy Circuit Components ............................................................................................................ 123
Apply Typical Circuit Data to a Project Circuit .............................................................................. 123
Contents
Create Circuit Components .......................................................................................................... 124
Change the Location of a Circuit on a Bus ................................................................................... 124
Populating Items with Data..................................................................................................................... 125
Apply Options to a Set of Tags ........................................................................................................... 126
Apply Lookup Table Data to Equipment ............................................................................................. 126
Apply a Typical Circuit to an Item ....................................................................................................... 127
Apply a Typical Control Station to an Item .......................................................................................... 128
Apply a Typical Schematic to an Item ................................................................................................. 129
Apply a Profile to an Item .................................................................................................................... 130
Apply a Set of Signals to an Item ........................................................................................................ 132
Apply a Typical Cable Block Diagram to an Electrical Item ................................................................ 133
Apply a Typical Schematic to an Instrument ....................................................................................... 134
Panel Management .................................................................................................................................. 135
Create a Cabinet ................................................................................................................................. 135
Create a Control Station ..................................................................................................................... 136
Edit Control Station Properties ............................................................................................................ 136
Create a Local Panel .......................................................................................................................... 137
Create a Junction Box ......................................................................................................................... 137
Define a Junction Box as a Consumer ............................................................................................... 137
Define a Local Panel as a Consumer ................................................................................................. 138
Create a Panel Circuit ......................................................................................................................... 138
Cable Management .................................................................................................................................. 139
Create a Reference Cable .................................................................................................................. 139
Edit Reference Cable Common Properties .................................................................................. 140
Create a Plant Cable ........................................................................................................................... 140
Edit Plant Cable Properties .......................................................................................................... 141
Delete a Cable .................................................................................................................................... 142
Deletion Rules for Cables ............................................................................................................. 142
Cable Glands ...................................................................................................................................... 143
Create Reference Glands ............................................................................................................. 143
Associate Cable Sides with Glands .............................................................................................. 143
Batch Associate Cable Sides with Glands ................................................................................... 143
Batch Dissociate Cable Sides and Glands ................................................................................... 144
Synchronize Cable Glands with Reference Cables in Batch Mode ............................................. 144
Synchronize Cable Gland Associations with a Specific Reference Cable ................................... 145
Size a Cable ........................................................................................................................................ 146
Batch Size Cables ............................................................................................................................... 147
Define Custom Basic Ampacity for Cable Sizing ................................................................................ 148
Example of a Custom Basic Ampacity Lookup Table .................................................................. 149
Use Custom Basic Ampacity to Size Cables ...................................................................................... 150
Required Data for Cable Sizing .......................................................................................................... 151
Thermal Sizing .............................................................................................................................. 151
Voltage Drop Calculations ............................................................................................................ 152
Short Circuit Sizing ....................................................................................................................... 152
Automatic Switch-On of the Sizing Required Flag ....................................................................... 153
Insert a Power Cable Between Equipment Items ............................................................................... 154
Create Parallel Cables ........................................................................................................................ 154
Replace Cables ................................................................................................................................... 155
Contents
Batch Replace Cable Side Associations ............................................................................................. 157
Single-Core Cable Assemblies ........................................................................................................... 157
Create a Single-Core Cable Assembly in the Electrical Index ..................................................... 157
Create a Single-Core Assembly Based on a Predefined Cable Assembly .................................. 159
Create a Reference Single-Core Cable Assembly ....................................................................... 160
Copy a Single-Core Cable Assembly from the Reference Data Explorer .................................... 161
Add a Single-Core Cable Assembly to a Profile ........................................................................... 162
Create a Busway ................................................................................................................................. 162
Account for the Installed Length of a Cable ........................................................................................ 163
Cable Routing .......................................................................................................................................... 165
Create a Cableway and Segments ..................................................................................................... 165
Assign Cableway Components to Segments ...................................................................................... 166
Define Routing for a Single Cable....................................................................................................... 166
Batch Route Cables ............................................................................................................................ 166
Clear Cable Routing ............................................................................................................................ 167
Set Different Cable Routes for Parallel Cables ................................................................................... 167
Select a Predefined Route for a Cable ............................................................................................... 168
Create a Predefined Cable Route ....................................................................................................... 168
Copy Cable Routing Definitions from Another Cable.......................................................................... 169
Edit Cableway Properties .................................................................................................................... 169
Segment Fill Validation ....................................................................................................................... 169
Set the Method for Segment Fill Validation ........................................................................................ 172
Set the Segment Fill Calculation Criterion .......................................................................................... 172
Cable Drums ............................................................................................................................................ 173
Create a Cable Drum .......................................................................................................................... 174
Edit Cable Drum Properties ................................................................................................................ 175
Assign Multiple Cables to a Cable Drum ............................................................................................ 175
Assign a Single Cable to a Cable Drum ............................................................................................. 176
Batch Assign Cables to Cable Drums ................................................................................................. 177
Optimization of Cable Drum Assignment ............................................................................................ 178
Batch Cable Dissociation from Drums ................................................................................................ 181
Rules Governing Cable Drum Calculations ........................................................................................ 181
Cancel Cable Assignment to a Cable Drum ....................................................................................... 182
Associating Equipment ........................................................................................................................... 183
Electrical Engineer .............................................................................................................................. 183
Find Other Parent Items in the Electrical Engineer ...................................................................... 185
Show Related Items in a New Electrical Engineer Window ......................................................... 186
Create an Electrical Association ......................................................................................................... 186
Rules for Associating Electrical Equipment .................................................................................. 187
Change an Existing Electrical Association .......................................................................................... 191
Rules for Changing Electrical Associations .................................................................................. 192
Dissociate an Item from Its Feeding Item ........................................................................................... 193
Associate Electrical Equipment with Feeders ..................................................................................... 194
Automatic Creation of Feeder Circuits ................................................................................................ 195
Associate Bus Riser Circuits with Coupler Circuits ............................................................................. 196
Associate a Control Station with an Electrical Item ............................................................................ 196
Associate a Control Station with Cables ............................................................................................. 197
Associate Cables of Control Stations with Equipment Circuits ........................................................... 197
Contents
Associate Cables of Instruments with Equipment Circuits ................................................................. 197
Associate a Power Cable with Electrical Equipment .......................................................................... 198
Associate Additional Power Cables with Electrical Equipment ........................................................... 198
Associate a Non-Power Cable with Electrical Equipment .................................................................. 199
Define Parallel Equipment .................................................................................................................. 200
Rules Governing Parallel Relations .............................................................................................. 201
Connect Equipment Items in Parallel ........................................................................................... 202
Create a Daisy-Chain Connection Pattern .......................................................................................... 202
Move Disconnect Equipment into Circuit ............................................................................................ 203
Move Disconnect Equipment out of Circuit ......................................................................................... 203
Load Association ..................................................................................................................................... 205
Associate Loads with a PDB in Batch Mode ....................................................................................... 205
Associate a Single Load with a PDB................................................................................................... 208
Display Bus Load Data ....................................................................................................................... 211
Balancing Loads.................................................................................................................................. 211
Validate Bus Loads ....................................................................................................................... 211
Balance Bus Loads ....................................................................................................................... 212
Calculating Bus Load Summaries ......................................................................................................... 214
Connectivity Between Buses .............................................................................................................. 219
Calculating Bus Loading ..................................................................................................................... 224
Bus Load Configuration Examples...................................................................................................... 228
Configurations A and B: A Single Load Connected to a Bus ....................................................... 228
Load Power Parameters ............................................................................................................... 228
Configuration C: Bus Totals with or without Converting Equipment Losses ................................ 231
Configuration D: Bus Totals Accounting for Load or Bus Coincidence Factors ........................... 233
Configuration E: A Bus with Mixed Loads .................................................................................... 234
Configuration F: Coupled Buses .................................................................................................. 236
Configuration G: Loads Powered by an Alternative Power Source ............................................. 238
Configuration H: Loads Connected in Parallel ............................................................................. 239
Configuration I: Multiple Loads Connected by a Junction Box ..................................................... 241
Configuration J: Loads Connected in a Daisy-Chain Pattern ....................................................... 243
Configuration K: A Space Heater Connected to an Auxiliary Contact ......................................... 245
Correcting Bus Power Factors Using Capacitor Banks ...................................................................... 247
Handling Special Cases of Bus Load Calculations ............................................................................. 248
Bus Load Calculation Preferences...................................................................................................... 248
Calculating Electrical Consumption After Batch Load Association ..................................................... 249
Flow of Activities for Bus Load Calculations ....................................................................................... 249
Bus, Circuit, and Converting Equipment Properties ........................................................................... 250
Bus Properties .............................................................................................................................. 250
Circuit Properties .......................................................................................................................... 252
Converting Equipment Properties ................................................................................................ 252
Calculate Bus Loads for Selected Buses or PDBs ............................................................................. 253
Calculate Bus Loads for All the Buses in the Plant............................................................................. 253
Generate an Enhanced All Feeder Load Summary Report ................................................................ 254
Drawing Templates.................................................................................................................................. 255
Create a Drawing Template ................................................................................................................ 255
Open a Drawing Template .................................................................................................................. 256
Title Block Macros ............................................................................................................................... 256
Contents
Plant Group Macros...................................................................................................................... 256
Document Property Macros .......................................................................................................... 257
Document Revision Macros ......................................................................................................... 257
Macros for Multi-Sheet Schematics.............................................................................................. 258
Enable the Renaming of Sheet Tabs in a Drawing ............................................................................. 258
Schematics ............................................................................................................................................... 259
Recommended Workflow for Generating Schematic Drawings .......................................................... 260
Working with the Elements of a Schematic Drawing .......................................................................... 261
Rename the Sheet Tabs in a Schematic Drawing .............................................................................. 262
Macro Definition Guidelines ................................................................................................................ 262
Macros Defined in Catalog Manager ............................................................................................ 263
Macro Syntax ................................................................................................................................ 263
Supported Electrical Items ........................................................................................................... 264
Sequencing Items in Block Macros ..................................................................................................... 265
Handling Load Feeders with Parallel Branches ........................................................................... 266
Handling Incomer and Feeder Circuit Internals ............................................................................ 266
Handling Converting Equipment Items ......................................................................................... 266
Handling Non-Power Related Items of Schematic Drawings ....................................................... 266
Macro Sequencing Example C ..................................................................................................... 269
Macro Sequencing Example D ..................................................................................................... 270
Macro Sequencing Example E ..................................................................................................... 271
Macro Sequencing Example F ..................................................................................................... 272
Generate a Schematic ........................................................................................................................ 273
Generate a Schematic for an Instrument ..................................................................................... 273
Generate a Multi-Item Schematic ....................................................................................................... 274
Generate a Multi-Item Schematic for a Bus ........................................................................................ 276
Set Units of Measure for Generated Schematic Drawings ................................................................. 277
Including Enhanced SmartLoop Reports with Schematics ................................................................. 277
Include Enhanced SmartLoop Reports with Schematics .................................................................... 278
Generate Schematics in Batch Mode ................................................................................................. 278
Open a Schematic Drawing ................................................................................................................ 279
Save a Schematic as an External File ................................................................................................ 279
Create Schematic Blocks in Catalog Manager ................................................................................... 279
Use a Complete Symbol File to Create Schematic Blocks in Catalog Manager ................................ 280
Create Schematic Blocks in SmartSketch .......................................................................................... 280
Guidelines for Creating Schematic Blocks in AutoCAD and MicroStation.......................................... 281
Single Line Diagrams .............................................................................................................................. 283
Working with SLD Elements ............................................................................................................... 285
Generating New Single Line Diagrams ............................................................................................... 287
Generate an SLD from the Electrical Engineer ............................................................................ 288
Generate a Single Line Diagram for a PDB ................................................................................. 289
Break Bus Symbols into Sections ................................................................................................ 290
Generate a Manual SLD ............................................................................................................... 291
Generate Multiple Single Line Diagrams for PDBs in Batch Mode .............................................. 291
Generate an SLD with a Bus Tie and Internal Components ........................................................ 292
Abort SLD Generation Process .................................................................................................... 293
Opening Existing Single Line Diagrams ............................................................................................. 293
Open an SLD Based on an Electrical Engineer Item ................................................................... 294
Open an SLD for a Power Distribution Board............................................................................... 294
Open an SLD from the Documents Folder ................................................................................... 294
Contents
Save a Single Line Diagram as an External File ................................................................................ 295
Show Control Stations in an SLD........................................................................................................ 295
Show Metering and Relaying Equipment in an SLD ........................................................................... 295
Displaying Equipment Connected in Parallel ...................................................................................... 296
Set Parallel Equipment Display Options ....................................................................................... 301
Hide PDB Sub-Items in an SLD .......................................................................................................... 302
Set the Extent of Downstream Branches ............................................................................................ 302
Placement of Circuits on Bus Sections ............................................................................................... 303
Hide Bus Feeders in an SLD .............................................................................................................. 303
Find an Electrical Item in an SLD........................................................................................................ 304
Insert a Legend in an Existing SLD..................................................................................................... 304
Use Custom Symbols in SLDs ............................................................................................................ 305
Customize a PDB Border (Frame) on an SLD .................................................................................... 305
PDB Frames Examples in SLDs .................................................................................................. 306
Remove an Item from an SLD ............................................................................................................ 307
Creating and Using Symbol Assemblies for SLD Diagrams ............................................................... 308
Create and Use a Symbol Assembly............................................................................................ 309
Gapping Lines ..................................................................................................................................... 309
Perform Line Gapping in Your Drawing Now ...................................................................................... 310
Guidelines for Creating SLD Symbols in Catalog Manager ................................................................ 310
General Guidelines ....................................................................................................................... 310
Connect Points ............................................................................................................................. 310
Origin Point ................................................................................................................................... 311
Special Symbols ........................................................................................................................... 311
Place Symbol Connect Points............................................................................................................. 313
Manipulating Smart Labels ................................................................................................................. 314
Create a Mirror Image of a Smart Label ............................................................................................. 314
Rotate a Smart Label .......................................................................................................................... 314
Align Smart Labels .............................................................................................................................. 315
Rename the Sheet Tabs in an SLD Drawing ...................................................................................... 315
Cable Block Diagrams............................................................................................................................. 317
Creating Cable Block Diagrams .......................................................................................................... 317
Create a Blank Project CBD ......................................................................................................... 318
Create a Project CBD Based on a Typical Cable Block Diagram ................................................ 318
Open an Existing Cable Block Diagram .............................................................................................. 319
Rename the Sheet Tabs in a CBD Drawing ....................................................................................... 320
Working with Smart Data and Auxiliary Graphics in a CBD ............................................................... 320
Place and Connect Items in a Cable Block Diagram .......................................................................... 324
Use Reference Items in a Cable Block Diagram ................................................................................ 325
Use a Reference Circuit in a Cable Block Diagram ............................................................................ 326
Mark Auxiliary Graphics on a Cable Block Diagram ........................................................................... 326
Remove Items from a Cable Block Diagram ....................................................................................... 327
Use Custom Symbols in Cable Block Diagrams ................................................................................. 327
Rules for Connecting to Circuit Symbols ............................................................................................ 328
Resolve Symbol Inconsistencies ........................................................................................................ 328
Hide Cable Types................................................................................................................................ 329
Define a Focal Item for a Cable Block Diagram .................................................................................. 329
Display a Filter Settings Notation in a CBD ........................................................................................ 330
Wiring in SmartPlant Electrical .............................................................................................................. 331
Create a Terminal Strip in the Electrical Index ................................................................................... 331
10
Contents
Create a Terminal in the Electrical Index ............................................................................................ 332
Define a Reference Terminal Strip Configuration ............................................................................... 332
Apply a Reference Terminal Strip Configuration to a Terminal Strip .................................................. 333
Define a Terminal Strip Configuration for a Single Terminal Strip ...................................................... 333
Wiring Project Items ............................................................................................................................ 334
Define a Connection Type ............................................................................................................ 335
Wire Project Items Using the Custom Connection Method .......................................................... 336
Wire Project Items Using the Continuous Connection Method .................................................... 337
Connect Project Cables in Batch Mode........................................................................................ 339
Connect a Cable Set .................................................................................................................... 340
Connect a Single Conductor ........................................................................................................ 340
Connect a Jumper ........................................................................................................................ 341
Disconnect a Cable, Cable Set, or Conductor in a Wiring Drawing ............................................. 341
Remove Items from a Wiring Drawing .......................................................................................... 342
Customize a Jumper Symbol ....................................................................................................... 342
Open an Existing Wiring Drawing ................................................................................................. 342
Working with Signals .............................................................................................................................. 344
Create a Signal ................................................................................................................................... 344
Associate I/O Signals .......................................................................................................................... 345
Dissociate I/O Signals ......................................................................................................................... 345
Customizing Symbols ............................................................................................................................. 347
Associate a Custom Symbol with Item Tags ...................................................................................... 347
Dissociate a Custom Symbol from an Item Tag ................................................................................. 348
Annotations and Redlining ..................................................................................................................... 349
Insert Annotation Text ......................................................................................................................... 349
Insert Annotation Symbols .................................................................................................................. 350
Edit Annotation Text ............................................................................................................................ 350
Delete Annotations .............................................................................................................................. 351
Insert Redlining Text ........................................................................................................................... 351
Insert Redlining Graphical Elements................................................................................................... 352
Edit Redlining Text .............................................................................................................................. 352
Delete Redlining .................................................................................................................................. 353
Drawing Items .......................................................................................................................................... 355
Find a Drawing Item in the Electrical Index or Electrical Engineer ..................................................... 355
View Associated Drawings of an Item ................................................................................................ 355
Show Related Items ............................................................................................................................ 356
Viewing Drawings................................................................................................................................ 356
Gapping Lines ..................................................................................................................................... 357
Perform Line Gapping in Your Drawing Now ............................................................................... 357
Aligning Drawing Objects .................................................................................................................... 357
Align Drawing Objects .................................................................................................................. 359
Align Command ............................................................................................................................ 360
Manipulating Drawing Items................................................................................................................ 360
Move a Drawing Item.................................................................................................................... 360
Mirror an Item About an Existing Mirror Axis or Linear Element .................................................. 361
Mirror an Item About a Mirror Axis That You Define .................................................................... 361
Mirror Ribbon ................................................................................................................................ 362
11
Contents
Rotate an Item About an Axis You Define .................................................................................... 362
Rotate Ribbon ............................................................................................................................... 362
Manipulating Smart Labels ................................................................................................................. 363
Create a Mirror Image of a Smart Label ....................................................................................... 364
Rotate a Smart Label.................................................................................................................... 364
Align Smart Labels ....................................................................................................................... 364
Working with Documents ....................................................................................................................... 365
Internal Documents in SmartPlant Electrical ...................................................................................... 365
Add a Document Revision ............................................................................................................ 365
Manage Global Revisions ............................................................................................................ 366
Compare an Archived Document with a Current Document ........................................................ 367
Batch Compare Documents ......................................................................................................... 368
External Documents ............................................................................................................................ 369
Define an External Document Reference ..................................................................................... 369
Associate External Documents with Electrical Items ................................................................... 370
Dissociate an External Document ................................................................................................ 370
Dissociate an External Document from Multiple Electrical Items in Batch Mode ......................... 371
Open an External Document ........................................................................................................ 371
Inserting External Graphics Files into SmartPlant Electrical Templates ............................................. 372
Insert an External Graphics File into a SmartPlant Electrical Template ...................................... 372
Tabular Editor .......................................................................................................................................... 373
Display the Tabular Editor ................................................................................................................... 374
Define a New Tabular Editor View ...................................................................................................... 374
Define a Filter for a Tabular Editor View ............................................................................................. 375
Define a New Layout for a Tabular Editor View .................................................................................. 375
Shipped Default Layouts .............................................................................................................. 376
Modify the Table Properties of an Existing Tabular Editor View ......................................................... 376
Save a Tabular Editor Layout ............................................................................................................. 377
Delete a Tabular Editor Layout ........................................................................................................... 377
Update Tabular Editor Data ................................................................................................................ 377
Search for Tags from the Tabular Editor ............................................................................................ 378
Use AutoFilter in the Tabular Editor .................................................................................................... 378
Copy Data from the Tabular Editor to an External File ....................................................................... 378
Print Tabular Editor Content ............................................................................................................... 379
Reports in SmartPlant Electrical ............................................................................................................ 381
Create a New Customized Report ...................................................................................................... 381
Generate a Report for Selected Items ................................................................................................ 382
Shipped Reports ................................................................................................................................. 382
All Feeder Load Summary (Enhanced) Report ............................................................................ 389
Customizing the Enhanced All Feeder Load Summary Report.................................................... 390
Registering Reports ............................................................................................................................ 391
Register a Report ......................................................................................................................... 391
Include Revision Data in Registered Reports .............................................................................. 391
Save Free Text in Registered Reports ......................................................................................... 393
Associate an Electrical Item with a Registered Report ................................................................ 394
Creating and Editing Report Templates .............................................................................................. 395
Display the Properties of a Report Template ............................................................................... 395
Create a New Blank Report Template .......................................................................................... 395
12
Contents
Create a Report Template Based on an Existing Template ......................................................... 396
Edit a Report Template................................................................................................................. 396
Define Report Headers ................................................................................................................. 397
Define the Contents of Your Report Template ............................................................................. 398
Define the Layout of a Tabular Format Report Template ............................................................. 400
Define the Layout of a Fixed Format Report Template ................................................................ 402
Define the Layout of a Composite Format Report Template........................................................ 402
Delete a Report Template ............................................................................................................ 403
Using KKS Naming Conventions in SmartPlant Electrical ................................................................. 405
Create a KKS Plant Using a Default DDT File .................................................................................... 407
Creating a KKS Plant Using a Supplied DDT File .............................................................................. 409
Propagation of KKS Names in SmartPlant Electrical.......................................................................... 416
SmartPlant Application Interfaces ......................................................................................................... 423
SmartPlant Instrumentation Interface ................................................................................................. 423
Prerequisites for Working with the SmartPlant Instrumentation Interface .................................... 424
Mapping Plant Groups to SmartPlant Instrumentation ................................................................. 425
Map Plant Groups to SmartPlant Instrumentation ........................................................................ 425
Retrieve Data from the SmartPlant Instrumentation Interface ..................................................... 426
Importing Cables from SmartPlant Instrumentation ............................................................................ 427
Synchronizing SmartPlant Instrumentation and SmartPlant Electrical Reference
Cables........................................................................................................................................... 427
Exporting SmartPlant Instrumentation Cables ............................................................................. 430
Importing Cables to SmartPlant Electrical .................................................................................... 430
Importing the To and From Objects.............................................................................................. 431
Workflow for Importing SmartPlant Instrumentation Cables ........................................................ 431
ETAP - SmartPlant Electrical Bidirectional Interface ........................................................................... 433
ETAP - SmartPlant Electrical Mapped Items ...................................................................................... 433
Preliminary Settings for ETAP ............................................................................................................ 436
Define the ETAP Project Name .................................................................................................... 436
Map ETAP File Location ............................................................................................................... 436
Import ETAP Mapping Data ......................................................................................................... 437
Set the ETAP-SPEL Reference Cable Exchange File Location .................................................. 437
Export SmartPlant Electrical Reference Cables (Power Cables) ................................................. 437
Export SmartPlant Electrical Reference Cables (Cable Specifications) ...................................... 439
Import ETAP Library Cables ......................................................................................................... 440
Publish a Single SLD Drawing to ETAP (Partial Publishing) .............................................................. 441
Publish All Plant SLDs to ETAP (Full Publishing) ............................................................................... 441
Retrieve ETAP Project Data ............................................................................................................... 442
Publishing Data for Interfaces................................................................................................................ 443
Publish Data from SmartPlant Electrical ............................................................................................. 443
Publish Equipment from SmartPlant Electrical ................................................................................... 445
Publishing Data to an External Analyzing Tool ................................................................................... 447
Project Management in SmartPlant Electrical ...................................................................................... 449
Scoping the Project ............................................................................................................................. 450
Understanding Statuses ...................................................................................................................... 450
13
Contents
Rules for Changing Statuses .............................................................................................................. 451
Modify Project Status .......................................................................................................................... 452
Scoping Items ..................................................................................................................................... 453
Select a Project ............................................................................................................................ 453
Rules for Scoping Items ............................................................................................................... 454
Add Items to the Project Management Table in As-Built.............................................................. 456
Scope Items .................................................................................................................................. 456
Use the Buffer to Scope Items ..................................................................................................... 457
Claiming Items .................................................................................................................................... 457
Add Items to the Project Management Table in a Project ............................................................ 458
Claim Items ................................................................................................................................... 458
Set Claim Mode ............................................................................................................................ 459
Release Claim .............................................................................................................................. 459
Mark Selected Items as Completed ............................................................................................. 460
Clear Mark as Completed ............................................................................................................. 460
Complete a Project ....................................................................................................................... 461
Return a Project to the Active Status ........................................................................................... 461
Release from Merge ..................................................................................................................... 461
Merging Items into As-Built ................................................................................................................. 462
Compare a Document in a Project with a Document in As-Built .................................................. 462
Rules Governing Revisions for Documents Merged Back into As-Built ....................................... 463
Run a Test Merge ......................................................................................................................... 464
Merge All Project Items into As-Built (Full Merge) ....................................................................... 464
Merge Selected Project Items into As-Built (Partial Merge) ......................................................... 465
Miscellaneous Options ........................................................................................................................ 465
Filter the Project Management Table Display .............................................................................. 466
Select a Display Option ................................................................................................................ 466
Generate an Excel Report ............................................................................................................ 467
Working with Off-Site Projects in SmartPlant Electrical ..................................................................... 469
Intercompany Collaboration Prerequisites for SmartPlant Electrical .................................................. 469
Types of Information Handled by Off-Site Projects............................................................................. 470
Scope of Allowed Activities ................................................................................................................. 471
Out of Scope Items ....................................................................................................................... 471
Flowchart for SmartPlant Electrical Off-Site Projects ......................................................................... 472
SmartPlant Electrical Off-Site Projects Workflow ............................................................................... 472
Scope Host Data and Transfer to Off-Site Plant .......................................................................... 474
Transfer Data from the Off-Site Plant to the Host ........................................................................ 482
Rescope and Synchronize Updated As-Built Data ....................................................................... 487
SmartPlant Electrical EPC Greenfield Plant Workflow ....................................................................... 492
Save a Plant Structure.................................................................................................................. 493
Create a Reference Data Package .............................................................................................. 493
Update Reference Data from a Package ..................................................................................... 494
Load a Plant as a Project ............................................................................................................. 495
SmartPlant Electrical Off-Site Projects Reference .............................................................................. 497
Save Project as Offsite Command (File Menu) ............................................................................ 497
Save Project as Offsite Dialog Box .............................................................................................. 498
Save Project for Reload Command (File Menu) .......................................................................... 499
Save Project for Reload Dialog Box ............................................................................................. 499
Save Plant for Merge in Host Command (File Menu) .................................................................. 500
Save Plant for Merge in Host Dialog Box ..................................................................................... 500
Load Offsite Plant Structure Command (File Menu) .................................................................... 501
Load Offsite Plant Structure Wizard ............................................................................................. 501
14
Contents
Load Plant as Project Command (File Menu) .............................................................................. 512
Load Plant as Project Dialog Box ................................................................................................. 513
Load Standalone Project Command (File Menu) ......................................................................... 514
Load Standalone Project Wizard .................................................................................................. 514
Working with SmartPlant Integration .................................................................................................... 517
Tool Requirements for Integrating SmartPlant Electrical .................................................................... 518
Working with SmartPlant Instrumentation .................................................................................... 518
Working with SmartPlant 3D ........................................................................................................ 519
Working with SmartPlant P&ID ..................................................................................................... 520
Using Projects in an Integrated Environment ............................................................................... 520
Access the SmartPlant Foundation Web Client .................................................................................. 520
Schema Mapping ................................................................................................................................ 521
General Information About Schema Mapping .............................................................................. 521
Mapping Rules and Limitations .................................................................................................... 522
Objects and Relationships ............................................................................................................ 523
Tool Schema Data Model Diagram .............................................................................................. 529
SmartPlant Electrical Mapping Examples .................................................................................... 530
Publish Operation Description ...................................................................................................... 540
Retrieve Operation Description .................................................................................................... 541
Publishing Documents ........................................................................................................................ 543
Prerequisites for Publishing .......................................................................................................... 544
Publish Documents from SmartPlant Electrical ............................................................................ 545
Publish Workflows ........................................................................................................................ 547
Find Documents to Publish from SmartPlant Electrical ................................................................ 548
Retrieving Documents ......................................................................................................................... 549
Retrieve Documents to SmartPlant Electrical .............................................................................. 552
Using the To Do List ........................................................................................................................... 553
Open the To Do List ..................................................................................................................... 553
Modify To Do List Task Properties ............................................................................................... 554
Run Tasks from the To Do List ..................................................................................................... 554
Filter To Do List Tasks.................................................................................................................. 554
Sort To Do List Tasks ................................................................................................................... 555
Defer Tasks from the To Do List .................................................................................................. 555
Remove Tasks from the To Do List .............................................................................................. 555
Display Deleted To Do List Tasks ................................................................................................ 555
Ignore To Do List Tasks ............................................................................................................... 556
Ignore Task Properties ................................................................................................................. 556
Display Ignored To Do List Tasks ................................................................................................ 556
Update the To Do List Display ...................................................................................................... 556
Compare a Document with a Published Version ................................................................................ 557
Menu Commands ................................................................................................................................ 559
Publish Plant Groups Command (SmartPlant Menu) ................................................................... 559
Publish Command (SmartPlant Menu) ......................................................................................... 559
Find Documents to Publish Command (SmartPlant Menu) ......................................................... 559
Retrieve Command (SmartPlant Menu) ....................................................................................... 559
Compare with Published Version Command (SmartPlant Menu) ................................................ 560
Publish to External Analyzing Tool Command (SmartPlant Menu) .............................................. 560
To Do List Command (SmartPlant Menu) .................................................................................... 560
Browser Command (SmartPlant Menu) ....................................................................................... 560
Upgrade Schema Command (SmartPlant Menu) ........................................................................ 560
Windows and Dialog Boxes ................................................................................................................ 561
To Do List Dialog Box ................................................................................................................... 561
15
Contents
Task Properties Dialog Box .......................................................................................................... 563
Appendix .................................................................................................................................................. 567
SmartPlant Electrical Data Model ....................................................................................................... 567
Customizing Your Data ....................................................................................................................... 567
Electrical Calculations ......................................................................................................................... 569
Calculations for Motors ................................................................................................................. 569
Calculations for Static Loads ........................................................................................................ 571
Earth Loop Impedance Calculation .............................................................................................. 573
Custom Validations and Calculations ................................................................................................. 574
Implement Validation .................................................................................................................... 574
Implement Calculation .................................................................................................................. 576
Validation Code Example ............................................................................................................. 577
Item Type Validation Example ...................................................................................................... 577
Switching the Plant Operational Mode ................................................................................................ 579
Custom Common Properties Forms ................................................................................................... 580
Create a Custom Common Properties Form ................................................................................ 580
Define Custom Forms in SmartPlant Electrical ............................................................................ 582
Select Common Properties Form Dialog Box .............................................................................. 584
Typical Cable Block Diagram Utility Dialog Box ................................................................................. 584
Menu Commands..................................................................................................................................... 587
New > Item Command (File Menu) ..................................................................................................... 587
New > SLD Command (File Menu) ..................................................................................................... 587
New > Template Command (File Menu) ............................................................................................. 587
New > Custom Folder (File Menu) ...................................................................................................... 587
Open > Plant Group Command (File Menu) ....................................................................................... 587
Open > Drawing Command (File Menu) ............................................................................................. 587
Open > PDB Layout Command (File Menu) ....................................................................................... 588
Open > SLD Command (File Menu) ................................................................................................... 588
Open > Template Command (File Menu) ........................................................................................... 588
Open > Log Files Command (File Menu) ............................................................................................ 588
Close Command (File Menu) .............................................................................................................. 588
Save Command (File Menu) ............................................................................................................... 588
Save As Command (File Menu) .......................................................................................................... 588
Preferences Command (File Menu) .................................................................................................... 588
Print Command (File Menu) ................................................................................................................ 589
Sheet Setup Command (File Menu..................................................................................................... 589
Properties Command (File Menu) ....................................................................................................... 589
Exit Command (File Menu) ................................................................................................................. 589
Undo Command (Edit Menu) .............................................................................................................. 589
Redo Command (Edit Menu) .............................................................................................................. 589
Cut Command (Edit Menu) ................................................................................................................. 589
Copy Command (Edit Menu) .............................................................................................................. 590
Paste Command (Edit Menu) .............................................................................................................. 590
Delete Command (Edit Menu) ............................................................................................................ 590
Select All Command (Edit Menu) ........................................................................................................ 590
Duplicate Command (Edit Menu) ........................................................................................................ 590
Rename Command (Edit Menu) ......................................................................................................... 590
Align Command (Edit Menu) ............................................................................................................... 590
Nudge Command (Edit Menu) ............................................................................................................ 591
Move Command (Edit Menu) .............................................................................................................. 591
16
Contents
Rotate Command (Edit Menu) ............................................................................................................ 591
Mirror Command (Edit Menu) ............................................................................................................. 591
Fit to Page Command (Edit Menu) ..................................................................................................... 591
Activate Connection Mode Command (Edit Menu) ............................................................................. 591
Activate Association Mode Command (Edit Menu) ............................................................................ 591
Show/Hide Association Connectors Command (Edit Menu) .............................................................. 592
Activate Jumper Mode Command (Edit Menu) ................................................................................... 592
Disconnect (Edit Menu) ....................................................................................................................... 592
Change Branch Orientation Command (Edit Menu) ........................................................................... 592
Remove (Edit Menu) ........................................................................................................................... 592
Redlining Command (Edit Menu) ........................................................................................................ 592
Move Cell Command (Edit Menu) ....................................................................................................... 592
Remove Cell Command (Edit Menu) .................................................................................................. 593
Insert > Image Command (Edit Menu) ................................................................................................ 593
Insert > Symbol Command (Edit Menu) .............................................................................................. 593
Insert > Text Command (Edit Menu) ................................................................................................... 593
Insert > Legend Command (Edit Menu) .............................................................................................. 593
Insert > Line Command (Edit Menu) ................................................................................................... 593
Insert > Circle Command (Edit Menu) ................................................................................................ 593
Insert > Rectangle Command (Edit Menu) ......................................................................................... 594
Insert > Curve Command (Edit Menu) ................................................................................................ 594
Text Command (Edit Menu) ................................................................................................................ 594
Document Properties Command (Edit Menu) ..................................................................................... 594
Common Properties Command (Edit Menu) ....................................................................................... 594
Table Properties Command (Edit Menu) ............................................................................................ 594
Transformer Connections and Tapping Command (Edit Menu) ......................................................... 595
Previous Zoom Level Command (View Menu) ................................................................................... 595
Refresh Command (View Menu) ......................................................................................................... 595
Show Selected Electrical Branches Only Command (View Menu) ..................................................... 595
Show in New Window Command (View Menu) .................................................................................. 595
Show Items of All Plant Groups Command (View Menu) ................................................................... 596
Show Related Items (View Menu) ....................................................................................................... 596
Add Filter Command (View Menu) ...................................................................................................... 596
Save Settings Command (View Menu) ............................................................................................... 596
Zoom Area Command (View Menu) ................................................................................................... 596
Zoom In Command (View Menu) ........................................................................................................ 596
Zoom Out Command (View Menu) ..................................................................................................... 596
Fit Command (View Menu .................................................................................................................. 597
Pan Command (View Menu) ............................................................................................................... 597
Show Grid Command (View Menu) .................................................................................................... 597
Snap to Grid Command (View Menu) ................................................................................................. 597
Show Auxiliary Graphics Symbology .................................................................................................. 597
Display > Properties Window Command (View Menu) ....................................................................... 597
Display >Working Area Command (View Menu) ................................................................................ 597
Display >Item Status in Project Command (View Menu) .................................................................... 597
Toolbars Command (View Menu) ....................................................................................................... 597
Design PDB Layout Command (Actions Menu) .................................................................................. 598
Batch Load Association Command (Actions Menu) ........................................................................... 598
Total Bus Load Validation Command (Actions Menu) ........................................................................ 598
Calculate Bus Loads > Selected PDBs or Buses Command (Actions Menu) .................................... 598
Calculate Bus Loads > All Plant Buses Command (Actions Menu).................................................... 598
Associate Bus with PDB Command (Actions Menu) .......................................................................... 598
Dissociate Bus from PDB Command (Actions Menu)......................................................................... 598
17
Contents
Generate SLD for PDB Command (Actions Menu) ............................................................................ 599
Generate Schematic Command (Actions Menu) ................................................................................ 599
Define Document Reference Command (Actions Menu) ................................................................... 599
Associate Documents Command (Actions Menu) .............................................................................. 599
Global Revisions Command (Actions Menu) ...................................................................................... 599
Compare Documents Command (Actions Menu) ............................................................................... 599
Resolve Symbol Inconsistencies Command (Actions Menu) ............................................................. 599
Associate Custom Symbols Command .............................................................................................. 600
Dissociate Command (Actions Menu) ................................................................................................ 600
Move Items Command (Actions Menu) .............................................................................................. 600
Switch Plant Operational Mode Command (Actions Menu) ............................................................... 600
Cables > Batch Size Cables Command (Actions Menu) .................................................................... 600
Cables > Replace Cables Command (Actions Menu) ........................................................................ 600
Cables > Apply Reference Data to Cables Command (Actions Menu) .............................................. 601
Cables > Assign Drums to Cables Command (Actions Menu) ........................................................... 601
Cables > Predefined Routes Command (Actions Menu) .................................................................... 601
Cables > Batch Cable Routing Command (Actions Menu) ................................................................. 601
Cables > Define Color Pattern Command (Actions Menu) ................................................................. 601
Cables > Refresh Load Data for Power Cables Command (Actions Menu) ....................................... 601
Cables > Associate Cables with Equipment Circuits Command (Actions Menu) ............................... 601
Cables > Batch Cable Side and Gland Associations Command (Actions Menu) ............................... 602
Cables > Batch Cable Connection Command (Actions Menu) ........................................................... 602
Cables > Batch Cable Dissociation from Drums Command (Actions Menu) ...................................... 602
Cables > Insert Power Cable (Actions Menu) ..................................................................................... 602
Parallel Equipment Assistant Command (Actions Menu) ................................................................... 602
Fix Inconsistencies Command (Actions Menu) ................................................................................... 603
Copy Driver Power Absorbed (Actions Menu) .................................................................................... 603
Register Report Command (Actions Menu) ........................................................................................ 603
Gap Now Command (Tools Menu) ..................................................................................................... 603
Optimize Overlapping Connectors ...................................................................................................... 603
Apply Options Command (Tools Menu) .............................................................................................. 603
Drawing Options Command (Tools Menu) ......................................................................................... 603
Update Select Lists (Tools Menu) ....................................................................................................... 604
Apply Naming Conventions (Tools Menu) .......................................................................................... 604
ETAP Interface > Publish All (Tools Menu) ........................................................................................ 604
ETAP Interface > Retrieve (Tools Menu) ............................................................................................ 604
New Command (Reports Menu) ......................................................................................................... 604
Edit Command (Reports Menu) .......................................................................................................... 604
Delete Command (Reports Menu) ...................................................................................................... 604
Plant Reports Command (Reports Menu) .......................................................................................... 604
My Reports Command (Reports Menu) .............................................................................................. 604
New > Table Command (Window Menu) ............................................................................................ 605
New > Electrical Index Command (Window Menu) ............................................................................ 605
New > Electrical Engineer Command (Window Menu) ....................................................................... 605
New > Reference Data Explorer Command (Window Menu) ............................................................. 605
New > Reference Electrical Engineer Command (Window Menu) ..................................................... 605
New > Project Management Command (Window Menu) ................................................................... 605
SmartPlant Electrical Help Command (Help Menu) ............................................................................ 605
Printable Guides Command (Help Menu) ........................................................................................... 606
SmartPlant Electrical on the Web Command (Help Menu) ................................................................ 606
SmartPlant Electrical Web Forum Command (Help Menu) ................................................................ 606
About SmartPlant Electrical Command (Help Menu) .......................................................................... 606
Copy Command (Edit Menu - Tabular Editor) .................................................................................... 606
18
Contents
Paste Command (Edit Menu - Tabular Editor) .................................................................................... 606
Select All Command (Edit Menu - Tabular Editor) .............................................................................. 606
Tabular Editor Shortcut Menu ............................................................................................................. 607
Windows and Dialog Boxes.................................................................................................................... 609
General ............................................................................................................................................... 609
Customize Dialog Box .................................................................................................................. 609
Description Dialog Box ................................................................................................................. 610
File Properties Dialog Box (File > Properties) .............................................................................. 610
Move Items to Plant Group Dialog Box ........................................................................................ 612
New Item Dialog Box .................................................................................................................... 612
Open Plant Group Dialog Box ...................................................................................................... 612
Open Plant Structure Dialog Box ................................................................................................. 612
Preferences Dialog Box ................................................................................................................ 613
Select Filter Dialog Box ................................................................................................................ 616
Save as PDF Dialog Box .............................................................................................................. 616
Switch Plant Operational Mode Dialog Box.................................................................................. 617
Toolbars Dialog Box ..................................................................................................................... 617
Toolbars Tab (Customize Dialog Box) ......................................................................................... 618
Update Select Lists Dialog Box .................................................................................................... 618
Associations ........................................................................................................................................ 620
Associated Drawings Dialog Box ................................................................................................. 620
Cables ................................................................................................................................................. 620
Apply Reference Data to Project Cables Dialog Box ................................................................... 620
Assign Drums to Cables Wizard ................................................................................................... 621
Batch Cable Side and Gland Associations Dialog Box ................................................................ 623
Batch Size Cables Window .......................................................................................................... 624
Cable Common Properties Dialog Box......................................................................................... 624
Cable Drum Common Properties Dialog Box ............................................................................... 639
Cable Set Properties Dialog Box .................................................................................................. 641
Cable Sizing Matrix Dialog Box .................................................................................................... 641
Cable Cuts Dialog Box ................................................................................................................. 642
Compare Project and Reference Cable Data Dialog Box ............................................................ 642
Compare Project and Reference Cable Data Dialog Box ............................................................ 643
Define Color Pattern Dialog Box .................................................................................................. 644
Insert Power Cable Dialog Box .................................................................................................... 645
Reference Gland Common Properties Dialog Box ....................................................................... 645
Reference Cable Library Dialog Box ............................................................................................ 647
Replace Cables Dialog Box .......................................................................................................... 647
Select Reference Cable Dialog Box ............................................................................................. 650
Drum Sizes Dialog Box................................................................................................................. 651
Synchronize Gland Associations Dialog Box ............................................................................... 651
Single-Core Cable Assembly Common Properties Dialog Box .................................................... 652
Reference Single-Core Cable Assembly Common Properties Dialog Box .................................. 653
Cable Block Diagrams ........................................................................................................................ 655
Create New Plant Circuits Dialog Box .......................................................................................... 655
Resolve Symbol Inconsistencies Dialog Box ............................................................................... 655
Cable Routing ..................................................................................................................................... 656
Actual Routing Path Dialog Box ................................................................................................... 656
Batch Cable Routing Dialog Box .................................................................................................. 657
Cableway Common Properties Dialog Box .................................................................................. 658
Cableway Segment Common Properties Dialog Box ................................................................... 658
External Routing Path Dialog Box ................................................................................................ 662
19
Contents
Reference Cableway Component Common Properties Dialog Box ............................................. 662
Predefined Routes Dialog Box ..................................................................................................... 664
Route Properties Dialog Box ........................................................................................................ 664
Routing Path Dialog Box .............................................................................................................. 665
Custom Folders ................................................................................................................................... 666
Custom Folder Properties Dialog Box .......................................................................................... 666
Filter Properties Dialog Box .......................................................................................................... 666
New Custom Folder Dialog Box ................................................................................................... 667
Select Filter Dialog Box ................................................................................................................ 668
Electrical Equipment ........................................................................................................................... 668
Apply Options Dialog Box ............................................................................................................. 668
Batch Load Association Dialog Box ............................................................................................. 674
Battery Bank Common Properties Dialog Box ............................................................................. 680
Converting Equipment Common Properties Dialog Box .............................................................. 683
Copy Driver Power Absorbed Dialog Box .................................................................................... 689
Description Dialog Box ................................................................................................................. 690
Disconnect Electrical Equipment Common Properties Dialog Box .............................................. 690
Electrical Motor Common Properties Dialog Box ......................................................................... 691
Generator Common Properties Dialog Box .................................................................................. 701
Instrument Common Properties Dialog Box ................................................................................. 705
Item Tag Dialog Box ..................................................................................................................... 710
Metering Equipment Common Properties Dialog Box .................................................................. 711
Other Electrical Equipment Common Properties Dialog Box ....................................................... 714
Parallel Equipment Assistant Dialog Box ..................................................................................... 721
Static Load Common Properties Dialog Box ................................................................................ 722
Transformer Connections and Tapping Dialog Box ..................................................................... 729
External Documents ............................................................................................................................ 731
Associate Documents Dialog Box ................................................................................................ 731
Define Document Reference Dialog Box...................................................................................... 732
Interfaces ............................................................................................................................................ 733
Retrieve Document Dialog Box .................................................................................................... 733
Internal Documents and Revisions ..................................................................................................... 733
Batch Compare Documents Dialog Box ....................................................................................... 733
Compare Documents Dialog Box ................................................................................................. 733
Document Properties Dialog Box ................................................................................................. 734
File Properties Dialog Box ............................................................................................................ 739
Global Revisions Dialog Box ........................................................................................................ 741
New Miscellaneous Drawing Dialog Box ...................................................................................... 742
Registered Report Common Properties Dialog Box ..................................................................... 742
Panels ................................................................................................................................................. 743
Cabinet Common Properties Dialog Box...................................................................................... 743
Control Station Common Properties Dialog Box .......................................................................... 747
Project Management ........................................................................................................................... 748
Project Management Table (As-Built) .......................................................................................... 748
Project Management Table (Project) ............................................................................................ 751
Project Status Dialog Box ............................................................................................................. 754
Select Project Dialog Box ............................................................................................................. 755
Power Distribution Boards .................................................................................................................. 755
Add New Internal Item Dialog Box ............................................................................................... 755
Circuit Common Properties Dialog Box ........................................................................................ 755
Circuit Dialog Box ......................................................................................................................... 758
Cell Size Dialog Box ..................................................................................................................... 759
Power Distribution Board Structure Dialog Box ........................................................................... 759
20
Contents
Select Alternative Power Source Dialog Box ............................................................................... 761
Total Bus Load Validation Dialog Box .......................................................................................... 761
Zoom Options Dialog Box ............................................................................................................ 762
Redlining and Annotations .................................................................................................................. 762
Text Properties Dialog Box ........................................................................................................... 762
Reference Items .................................................................................................................................. 763
Associate Reference Cable Dialog Box ....................................................................................... 763
Equipment Profile Properties Dialog Box ..................................................................................... 764
Lookup Table Properties Dialog Box ............................................................................................ 767
Reference Cable Common Properties Dialog Box ....................................................................... 769
Reference Control Station Common Properties Dialog Box ........................................................ 774
Schematic Sheet Properties Dialog Box ...................................................................................... 774
Select Reference Cable Dialog Box ............................................................................................. 775
Typical Circuit Common Properties Dialog Box ........................................................................... 776
Typical Cable Block Diagram Properties ...................................................................................... 777
Typical Schematic Blocks Dialog Box .......................................................................................... 777
Typical Schematic Common Properties Dialog Box ..................................................................... 778
Reports and Report Templates ........................................................................................................... 779
Define Report Contents Dialog Box ............................................................................................. 779
Define Report Items Dialog Box ................................................................................................... 780
Delete Report Template Dialog Box ............................................................................................. 781
Edit Report Template Dialog Box ................................................................................................. 781
My Reports Dialog Box ................................................................................................................. 782
New Items Dialog Box .................................................................................................................. 782
New Report Template Dialog Box ................................................................................................ 783
Plant Reports Dialog Box ............................................................................................................. 783
Report Options Dialog Box ........................................................................................................... 784
Report Preferences Dialog Box .................................................................................................... 784
Report Properties Dialog Box ....................................................................................................... 785
Schematics.......................................................................................................................................... 785
Batch Generate Schematics Dialog Box ...................................................................................... 785
Generate Schematic Dialog Box .................................................................................................. 786
Multi-Tag Schematic Options Dialog Box ..................................................................................... 788
Options Dialog Box ....................................................................................................................... 788
Sheet Setup Dialog Box ............................................................................................................... 797
Size and Scale Tab (Sheet Setup Dialog Box) ............................................................................ 797
Single Line Diagrams .......................................................................................................................... 798
Single Line Diagram Options Dialog Box ..................................................................................... 798
Batch Options for SLDs Dialog Box ............................................................................................. 810
Open Single Line Diagram Dialog Box ......................................................................................... 811
SLD Legend Dialog Box ............................................................................................................... 811
Change Branch Orientation Dialog Box ....................................................................................... 811
Symbols .............................................................................................................................................. 812
Associate Custom Symbols Dialog Box ....................................................................................... 812
Tabular Editor...................................................................................................................................... 812
Advanced Table Properties Dialog Box ........................................................................................ 813
Custom AutoFilter Dialog Box ...................................................................................................... 815
New Filter Dialog Box ................................................................................................................... 815
Select Filter Dialog Box ................................................................................................................ 815
Table Properties Dialog Box ......................................................................................................... 816
Troubleshooting Errors and Rule Inconsistencies .............................................................................. 816
Log Files Dialog Box..................................................................................................................... 816
Fix Inconsistencies Dialog Box ..................................................................................................... 817
21
Contents
Rule Inconsistencies Dialog Box .................................................................................................. 817
Rule Properties Dialog Box .......................................................................................................... 818
Wiring .................................................................................................................................................. 821
Batch Cable Connection Dialog Box ............................................................................................ 821
Cable Connection Type Selection Dialog Box ............................................................................. 822
Connection Type Dialog Box ........................................................................................................ 822
Terminal Strip Configuration Dialog Box ...................................................................................... 823
Terminal Strip Common Properties Dialog Box ........................................................................... 824
Terminal Common Properties Dialog Box .................................................................................... 825
Toolbars and Ribbons ............................................................................................................................. 827
Actions Toolbar ................................................................................................................................... 827
Align Ribbon ........................................................................................................................................ 828
Change Toolbar .................................................................................................................................. 829
Draw Toolbar ....................................................................................................................................... 830
Edit Drawing Toolbar .......................................................................................................................... 831
Label Toolbar ...................................................................................................................................... 832
Main Toolbar ....................................................................................................................................... 832
Modify Connector Ribbon ................................................................................................................... 834
Using Help ................................................................................................................................................ 837
Glossary ................................................................................................................................................... 839
Index ......................................................................................................................................................... 853
22
SECTION 1
Electrical Index
Enables you to quickly create, modify, view, and select items in your project inventory. For more
information, see Electrical Index (on page 66).
Electrical Engineer
Enables you to create, modify, and display the electrical relations between various electrical
items. In this way, you establish the electrical infrastructure. For more information, see
Electrical Engineer (on page 183).
23
Properties Window
Displays the data fields of the currently selected item in tabular style where you can edit the
property values as needed. For more information, see Properties Window (on page 72).
Tabular Editor
Enables viewing and editing of items of the same type, and batch assignment of properties to a
selected group of items. You can also use the Tabular Editor to select items for including in
reports. For more information, see Tabular Editor (on page 373).
Status Bar
Displays summary information about selected menu items, processes, and tips when performing
particular actions. For more detailed information, refer to the appropriate SmartPlant Electrical
Online Help topic.
24
SECTION 2
In This Section
Connecting to a Plant Group ......................................................... 25
Create a Plant Using Reference Data from an Existing Plant ....... 27
25
26
A message is displayed at the start of SmartPlant Electrical informing you that changes have
been made to the naming conventions. This message reappears every time SmartPlant
Electrical is run until you use the Apply Naming Conventions command.
Due to the possibility that the naming convention and inter item tag dependency can be very
complex the software runs the Apply Naming Conventions twice. After running the update
there may still be items that have not been updated. You can run the Apply Naming
Conventions again. You can also update the item names by using the Comply with
Naming Conventions in the Plant-Wide Parameters dialog box in SmartPlant Options
Manager.
The changes are made to the item types in a specific order. The running order for the item
type name changes is:
BatteryBank - BatteryCharger - Busway - Cabinet - CableDrum - CableWay - Capacitor CurrentLimitingReactor - Generator - HarmonicFilter - Heater - HeatTrace - JunctionBox LocalPanel - Motor - OffSitePower - OtherConvertingEquipment - OtherElectEquipment PowerDistributionBoard - Resistor - Transformer - UPS - VariableFrequencyDrive - Bus CableWaySegment - ControlStation - Instrument - Ammeter - Circuit - CircuitBreaker Contactor - CurrentTransformer - DisconnectSwitch - Fuse - Multimeter OtherDisconnectEquipment - OverloadRelay - PotentialTransformer - ProtectionRelay SignalRun - Starter - Voltmeter.
4.
5.
6.
7.
8.
9.
You must perform this step if you want to the naming conventions to be available
for copying when you associate the target plant with SmartPlant Electrical.
Open SmartPlant Engineering Manager.
In the left pane (tree view), select the plant that you want to use as the source plant.
In the right pane, select the application, right-click, and click New Data Dictionary Template.
Navigate to the path where you want to create a template (.ddt) file containing the source
reference data and type a name for the file.
In the left pane, create a new plant or select an existing plant that is not associated with an
application. This will be your target plant.
Right-click the Applications sub- folder for the target plant and click Associate
Applications.
27
28
SECTION 3
Customizing Preferences
You can set various preferences for SmartPlant Electrical. The software allows you to set general
preferences as well as preferences for SLDs, load summary reports, and load deletions.
The general preferences let you specify whether to open a dialog box after creating or duplicating
an item, activating the use of log files for reporting errors after performing some batch operations,
displaying in the Electrical Engineer buses, incomers, and bus risers together with the
associated PDB item tags.
SLD preferences allow you to customize various generation settings such as displaying NULL in
the generated drawing when there is no data, setting various margin settings, setting a distance
for SLD internal elements, and so forth.
The report settings let you specify the data that the software will use to generate your load
summary reports.
The delete load settings allows you to customize which related (sub) items of a main item are
deleted when deleting a main item from the Electrical Index.
Your preferences customization does not affect the preferences set by other users in the
plant. However, a user with Administrator rights can set new defaults and override your
user-defined preferences.
29
Customizing Preferences
30
Customizing Preferences
7. Under Distance for SLD internals, enter values and select a unit of measure for
representation of buses, circuits and circuit components in a generated SLD:
In Distance between circuits, set the horizontal distance between the circuits above and
below the buses.
In Distance between buses, set the horizontal distance between the buses.
In Distance between circuit internals, set the vertical distance between the circuit
internal components (fuses, starters, and so forth).
8. Click OK or another tab.
31
Customizing Preferences
32
SECTION 4
33
34
Fix Inconsistencies
This option checks for rule violations, performs any copy rule operations, fixes any inconsistencies
that are found, and displays a summary of rule violations that may have occurred for the selected
items. You can also display the log file in Excel format if you require.
1. Click Actions > Fix Inconsistencies.
2. To display the log file as an .xls file, on the Fix Inconsistencies dialog box, click Show Log.
To make this feature available in SmartPlant Electrical, in the General Settings of
Options Manager, select Enable for the Consistency Rules setting.
Description
Rule Example
>
greater than
>=
<
smaller than
35
36
Operator
Description
Rule Example
<=
<>
or equal to
IN
Is Null
Is Not Null
SECTION 5
In This Section
Reference Data Explorer ............................................................... 37
Shipped Reference Data ............................................................... 39
Create a Reference Item ............................................................... 40
Copy a Reference Item to the Electrical Index .............................. 40
Create a Typical Electrical Motor ................................................... 41
Create Typical I/O Signals ............................................................. 42
Creating Typical Panels ................................................................. 42
Create a Typical Circuit ................................................................. 44
Create a Profile .............................................................................. 45
Working with Typical Cable Block Diagrams ................................. 47
Create Typical Schematic Blocks .................................................. 51
Create a Typical Schematic ........................................................... 53
Working with Lookup Tables.......................................................... 56
Reference Electrical Engineer ....................................................... 61
Toolbar
The toolbar contains the following options:
Find Click Find
to open the Find dialog box. Click Close to close the active Reference
Data Explorer window.
Refresh Click Refresh
to update the Reference Data Explorer display. This feature is
useful where multiple users are working on the same set of data.
37
You can create several instances of the Reference Data Explorer by clicking Window > New
> Reference Data Explorer.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
38
The shipped reference data uses American regional settings; in other countries which use
different regional settings, you have to replace the supplied reference data with data that was
created using the appropriate regional settings, to ensure that the software uses the correct
standard values for performing calculations.
In addition to using the shipped standard reference data, you can populate the plant with
reference data that you can download from a network location using the Options
Manager. The download contains the following reference items:
Lookup tables containing typical IEC motor data
Lookup tables containing typical ANSI motor data
Lookup tables containing NEC motor data with appropriate FLA and LRC values (NEC
tables 430-7b, 430-147 through 151)
IEC reference cables
ANSI reference cables
39
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You access this dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the item. For full details of the properties, see the
appropriate dialog box topic.
40
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You access this dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the item. For full details of the properties, see the
appropriate dialog box topic.
When you copy a reference item, the software copies the item properties, except for the Item
tag property, which follows the item naming convention.
For an item that includes sub- items, such as a typical circuit with internal components, the
software copies the sub-items as well. In this case, the sub-items are the circuit components.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new
electrical motor.
The Electrical Motor Common Properties dialog box shows the most commonly used
properties. You access this dialog box by clicking the Common Properties command on the
shortcut menu or you can specify in the preferences to open the dialog box directly when you
create a new electrical motor.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
When you add a motor with a space heater, the heater appears as a sub-item of the motor. If
you subsequently delete the motor, the software also deletes the heater.
41
42
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new typical
cabinet.
You access the Cabinet Common Properties dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create a new typical cabinet.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new typical
control station.
You access the Reference Control Station Common Properties dialog box by clicking the
Common Properties command on the shortcut menu or you can specify in the preferences to
open the dialog box directly when you create a new typical control station.
43
44
Create a Profile
You can create a profile for an item in the Reference Data Explorer and use it to create
associated items as well as to define default values for the main item and associated items in the
Electrical Index.
1. In the Reference Data Explorer, expand the Profiles folder hierarchy by clicking the + icon
and select the item type folder for the profile that you want to create.
2. Right-click the folder and then click New Profile.
3. Accept the default item tag or type a name of up to 80 characters for the profile.
If you are creating a number of profiles at one time, you may want to stop at this point and
edit the profile properties at a later stage.
45
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new profile.
You access the Equipment Profile Properties dialog box (on page 764) by clicking the
Common Properties command on the shortcut menu or you can specify in the preferences to
open the dialog box directly when you create a new profile.
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Apply a Profile to an Item (on page 130).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
If you want to use this profile as the default whenever you apply a profile to an item,
select Set as default.
5. Under Default reference item, select a reference item for copying the property values when
you apply the profile.
If you choose a motor that includes an internal heater, the Space Heater tab becomes
enabled.
6. To associate cables with the item referenced in the profile, under Associated cables, click
Add to open the Select Reference Cable dialog box, where you can select the desired cable.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
46
47
You can drag the following reference items to an open cable block diagram:
All electrical equipment items apart from power distribution boards, buses, and relay
functions.
You can drag disconnect electrical equipment items if they are stand-alone items, that
is, if they do not belong to any circuits.
Metering equipment items can be dragged only if they are current transformers or
potential transformers.
All wiring equipment items (panels, cables, and so forth) apart from busways, glands and
cableway components.
48
If you place typical circuits, reference control stations, or reference instruments that are
associated with typical cables, the software places these reference cables on the drawing and
retains the associations.
If you delete any of the reference items that have been placed on a typical drawing, this item
will no longer appear on the drawings.
In addition to smart graphics, you can also add auxiliary graphics, redlining, and annotations to
your CBD. For details, see Working with Smart Data and Auxiliary Graphics in a CBD (on page
320). Once you save the drawing, the software retains all your additions and modifications.
You can create a project CBD based on a predefined typical CBD. For details, see Creating
Cable Block Diagrams (on page 317).
49
If you choose not to use a custom symbol assembly for a reference junction box or local panel.
the software will place associated circuits on the drawing automatically and it will also display
the non -power flow association connectors between the junction box and the local panel. You
can hide these connectors if you like. For details, see Hide Association Connectors (on page
51).
Note that the rules stated above apply only to typical circuits that have been created
under reference junction boxes and local panels and not to typical circuits that have been created
in the Typical Circuits folder of the Reference Data Explorer.
The software indicates that connection mode is active by changing mouse pointer to a
vertical line.
The software stays in the connection mode until you press the Esc key.
5. Click one of the required items and then the other item to associate them with each other.
The software places a logical connector between the associated items. The logical
connector is shown as a black dashed line.
To dissociate two items from each other, do one of the following:
50
Click the required logical connector and then press the Delete key or click
the Edit drawing toolbar.
Remove one of the associated items from the drawing.
(Remove) on
By hiding the association connectors, you are not dissociating the items from each other.
To cancel an association, do one of the following:
Click the required logical connector and then press the Delete key or click
the Edit drawing toolbar.
Remove one of the associated items from the drawing.
(Remove) on
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new typical
schematic block.
You access the Typical Schematic Block Common Properties dialog box by clicking the
Common Properties command on the shortcut menu or you can specify in the preferences to
open the dialog box directly when you create a new typical schematic block.
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Create a Typical Schematic (on page 53).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
51
You can only select drawing files from the default folder specified in the Options
Manager; you can navigate to other folders, but you will not be able to select any files in those
folders.
5. Click Add to add the block to the library without having to close the dialog box.
6. To delete from the database a block that is not used in any typical schematic, select the
desired block and click Delete.
7. When done, click Apply.
52
Each block can have one or more associated macros. You can define and edit macros using
the Catalog Manager or an external CAD application such as SmartSketch, AutoCAD, or
MicroStation.
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Create a Typical Schematic (on page 53).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new typical
schematic.
You access the Typical Schematic Common Properties (see "Typical Schematic Common
Properties Dialog Box" on page 778) dialog box by clicking the Common Properties
command on the shortcut menu or you can specify in the preferences to open the dialog box
directly when you create a new typical schematic.
You can add various macros to the title block that will appear in the schematic drawing. For
more details, see Title Block Macros (on page 256).
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Create a Profile (on page 45).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
53
You can assign the same block to several different sheets if you want the block to appear
more than once on different sheets of the same schematic.
Note that the software does not retain in the database the sheets that have not been
assigned to blocks.
9. To remove a block from the schematic, select the desired block under Schematic blocks and
click Remove.
10. When done, click Apply.
54
You can assign the same block to several different sheets if you want the block to appear more
than once on different sheets of the same schematic.
You should assign a sheet to each block in the typical schematic. Unassigned sheets are not
kept in the database by the software.
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Create a Profile (on page 45).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
55
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new lookup
table.
You access the Lookup Table Properties dialog box (on page 767) by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create a new lookup table.
56
The software uses key field values to identify the data to update using the appropriate
values for the output fields.
The software treats read- only data as input only, and the Input-output value property is
disabled for such data.
9. From Overwrite option, select True if you want to overwrite existing data when you apply the
lookup table values, or select False to insert the values only where no data exists previously.
10. Repeat the preceding steps for as many other properties as you require.
11. If required, change the order of the properties under Definition by selecting an individual
property and clicking Up or Down.
The order of the properties affects how they are arranged on the Data tab. It is usually
convenient to arrange the input properties at the beginning, followed by the output
properties. For more details, see Lookup Table Structure Example (on page 58).
12. Click the Data tab and enter data values for the desired properties.
13. Enter data values for the properties that you require on the blank line.
You can right-click individual cells to copy and paste data. To copy and paste entire rows
of data, select the source row and click Copy Row. Next, select the target row and click
Paste Row.
Ensure that each combination of data in the key fields is unique. If you enter duplicate
key fields in two rows, the software displays a warning message and highlights the
duplicate row so that you can modify he input data. For more details, see Lookup Table
Data Example (on page 58).
You can sort the rows of data according to a particular column by clicking the column
header. Repeatedly clicking a column header displays the data in alternating ascending
and descending order.
14. Repeat the previous step for each set of data required.
You can define as many lookup tables as you require for a particular item type.
There are three specific lookup tables for conductors that cannot be deleted: Conductor
Material Coefficients, Conductor Insulation Temperatures, and Conductor Area
cmils. These tables contain typical values for some of the most common conductor materials
and conductor insulation materials. You should check these typical values and make sure
they comply with and match the values used or specified by local codes or cable
manufacturers. The software uses the data in these lookup tables for short circuit cable sizing
and you should add appropriate data for any additional conductor material or insulation if
needed.
57
58
4.
5.
6.
7.
8.
9.
10.
11.
If you are creating a number of lookup tables at one time, you may want to stop at this
point and edit the lookup table properties at a later stage.
On the Lookup Table Properties dialog box, edit the lookup table properties as
required. For more details, see Edit Lookup Tables (on page 56).
Create or edit the properties of a typical circuit in the Reference Data Explorer. For details,
see Create a Typical Circuit (on page 44).
On the Typical Circuit Common Properties dialog box, under Details of circuit internals,
select an appropriate lookup table from Lookup Table list.
In the Electrical Index, select a project circuit to which you want to apply a lookup table.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Lookup Tables tab.
Select the Enable associated lookup tables of circuit internals check box.
Click Apply.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new lookup
table.
You access the Lookup Table Properties dialog box by clicking the Common Properties
command on the shortcut menu or you can specify in the preferences to open the dialog box
directly when you create a new lookup table.
59
4.
5.
6.
7.
8.
9.
10.
11.
60
If you are creating a number of lookup tables at one time, you may want to stop at this
point and edit the lookup table properties at a later stage.
On the Lookup Table Properties dialog box, edit the lookup table properties as
required. For more details, see Edit Lookup Tables (on page 56).
Create or edit the properties of a typical circuit in the Reference Data Explorer. For details,
see Create a Typical Circuit (on page 44).
On the Typical Circuit Common Properties dialog box, under Details of circuit internals,
select an appropriate lookup table from Lookup Table list.
In the Electrical Index, select a project circuit to which you want to apply a lookup table.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Lookup Tables tab.
Select the Enable associated lookup tables of circuit internals check box.
Click Apply.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new lookup
table.
You access the Lookup Table Properties dialog box by clicking the Common Properties
command on the shortcut menu or you can specify in the preferences to open the dialog box
directly when you create a new lookup table.
Toolbar
The toolbar contains the following options:
Find Click Find
to open the Find dialog box where you can look for a specific item in the
Electrical Engineer. Click the arrow to display a menu with the following options:
Find Opens the Find dialog box where you can look for a specific item in the Reference
Electrical Engineer.
Close Closes the active Reference Electrical Engineer window.
Refresh Click Refresh
to update the Reference Electrical Engineer display. This
feature is useful where multiple users are working on the same set of data.
Buttons Buttons provide a useful shortcut to an item or a group of items. Click Buttons
to toggle show / hide for existing buttons. To create a button for the currently selected item or
folder, click the arrow and click Add Button. To remove a button, select the button to remove,
then click the arrow, and click Remove Button. Note that if you do not select any button to
remove, the software removes the uppermost button in the list.
61
You can open several instances of the Reference Electrical Engineer by clicking Window >
New > Reference Electrical Engineer.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
62
You can open more than one Reference Electrical Engineer and copy data from different
plants to your current plant.
You can drag a parent item from the Reference Electrical Engineer to the root of your
current plant.
You can open an instance of the Reference Electrical Engineer for your current plant to
duplicate your current plant data. In this case, the results you obtain are not the same as if
you move items within the Electrical Engineer. For details of how the software copies data
from the Reference Electrical Engineer to the Electrical Engineer, see Rules Governing
the Copying of Power Network Structures to the Electrical Engineer (on page 63).
When you copy items from the Reference Electrical Engineer to the Electrical Engineer,
the item does not appear in the Electrical Index. To update the item in the Electrical Index,
click Refresh
.
63
When dragging to your project Electrical Engineer a branch that includes an auxiliary contact,
the rules are as follows:
If the auxiliary contact belongs to a standalone disconnect equipment item (for example, a
disconnect switch), the software creates the new branch in the project Electrical Engineer
only up to and not including the auxiliary contact. The parent disconnect electrical equipment
item of the auxiliary contact is not copied.
If the auxiliary contact belongs to disconnect electrical equipment and this disconnect
electrical equipment item is an internal component of a circuit, the software creates the new
branch in the project Electrical Engineer only up to and not including the auxiliary contact.
The parent disconnect electrical equipment item of the auxiliary contact is not copied.
If you drag to the project Electrical Engineer a branch that contains a disconnect electrical
equipment item that has an auxiliary contact, the software creates the following in the project
Electrical Engineer:
The full disconnect equipment branch.
The auxiliary contact.
All the electrical items belonging to the downstream branch of the auxiliary contact.
64
SECTION 6
In This Section
Using Naming Conventions ........................................................... 65
Electrical Index .............................................................................. 66
Properties Window ......................................................................... 72
Create a New Item in the Electrical Index ..................................... 77
Create a Project Item Based on a Reference Item ........................ 77
Edit Item Properties ....................................................................... 78
Duplicate an Item ........................................................................... 78
Rename an Item ............................................................................ 79
Delete an Item ............................................................................... 79
Working with Loads ....................................................................... 81
Managing Space Heaters and Their Power Supplies .................... 89
Create a Generator ........................................................................ 99
Create an Offsite Power Supply .................................................... 100
Create a Battery Bank ................................................................... 101
Converting Equipment ................................................................... 101
You can override the default naming convention mode for one or more individual tags by
selecting the desired tags, and in the Properties window, changing the value of the Comply
with Naming Convention property.
65
If you change the value of the Comply with Naming Convention property for an item tag
from False to True, the software designates a new item tag for the item based on the naming
convention.
Whether or not you use the naming convention, the software always prompts you with a new
item tag that is unique.
Electrical Index
The Electrical Index is the repository of all your project electrical items. You create and manage
the electrical inventory of your project using edit, duplicate, and delete operations. The electrical
items in the Electrical Index are organized by item type categories in a parent-child relationship.
This parent-child relationship is illustrated in the following example for a current transformer. To
see an existing current transformer, expand the following hierarchy in the Electrical Index:
Electrical Equipment > Converting Equipment > Transformers >a transformer item >Metering
Equipment > a current transformer item.
For more details about the creation and management of electrical items, see Creating and
Modifying Equipment (on page 65).
You can create electrical associations by dragging an electrical item from the Electrical Index to
the Electrical Index. For details, see Electrical Engineer (on page 183).
The Electrical Index window contains the following sections:
Toolbar
Tree view pane
List view pane
These sections are described below:
Toolbar
The toolbar contains the following options:
Find Click Find
to open the Find dialog box where you can look for a specific item in the
Electrical Index. Click the arrow to display a menu with the following options:
Find Opens the Find dialog box where you can look for a specific item in the Electrical
Index.
Find in Electrical Engineer Searches the Electrical Engineer for the item that is currently
selected in the Electrical Index. Note that both the Electrical Engineer and the Electrical
Index have to be open if you want to use this feature.
Close Closes the active Electrical Index window.
Refresh Click Refresh
to update the Electrical Index display. This feature is useful
where multiple users are working on the same set of data.
Views The Views icon
allows you to toggle through different views of the items in the
list view pane. The arrow beside the icon allows you to select a specific view.
Buttons Buttons provide a useful shortcut to an item or a group of items. The Buttons icon
allows you to toggle between showing and hiding existing buttons. The arrow beside the
icon includes options that allow you to add or remove buttons for the currently selected item or
folder. Note that when removing a button, if you do not select a specific button, the software
removes the uppermost button in the list.
66
You can open several instances of the Electrical Index by clicking Window > New >
Electrical Index.
You can right-click any item in the Electrical Index to find it in the Electrical Engineer or click
an item in the Electrical Engineer to find it in the Electrical Index. Both the Electrical
Engineer and the Electrical Index have to be open if you want to use this feature.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
Customizing Folders
As your database in SmartPlant Electrical expands, the need to organize the various item types
into sub-categories becomes apparent. Using custom folders you can create sub-folders for each
item type folder. You can use these folders to divide item types into smaller more manageable
sections, for example within Wiring Equipment > Cables > Power Cables you could divide the
cables by manufacturer, cable specification, or insulation material. Using filters you can place
power cables into more than 1 folder, for example you could create a folder for all power cables
manufactured by a specific company, and another folder for all power cables that meet NEC
specifications, a power cable manufactured by the specific company and that has an NEC
specification appears in the folder created for the manufacturer, and appears in the folder created
for NEC specification power cables, along with all other power cables that have NEC
specifications. The software creates the duplicate items without moving the original item from the
Electrical Index or the Reference Data Explorer.
67
68
The first time you create a custom folder, a second folder called All Items is also created in
the parent folder. All the items in the parent folder are moved to this folder.
Only a maximum of 24 custom folders can be created.
Items that match the filter criteria are automatically duplicated in the custom folder, without
moving them from the All Items folder.
Some standard folders already have a hard-coded filter, for example the power cables folder
has a hard-coded filter CableCategory = <Property>. When a hard-coded filter already
exists, the filter definition has to be set correctly or this could result in incorrect items
appearing in your custom folder. The filter definition for the custom folder should be Match
all, or the criteria of the existing hard-coded filter should be included in the filter for the custom
folder. For example; CableCategory = Power Cable and Conductor Arrangement = 3 core
cable.
You create filters using Filter Manager, for more information, see Using Filters in the Filter
Manager User's Guide, under Using Filters.
Some standard folders already have a hard-coded filter, for example the power cables folder
has a hard-coded filter CableCategory = <Property>. When a hard-coded filter already
exists, the filter definition has to be set correctly or this could result in incorrect items
appearing in your custom folder. The filter definition for the custom folder should be Match
all, or the criteria of the existing hard-coded filter should be included in the filter for the custom
folder. For example; CableCategory = Power Cable and Conductor Arrangement = 3 core
cable.
69
You can add as many attribute name rows in the XML file as you need. We do not
recommend having more than three attributes so that not to affect the software performance.
ItemType name can be any item type that you need. "Motor" is given as an example.
The order can be either ascending (A) or descending (D).
The customization applies to folders in the Electrical Index and Reference Data Explorer.
This customization applies to main folders and does not apply to sub-folders.
This customization cannot be set according to select list properties or properties with attached
units of measure.
Example: <Root>
<ItemType name="Motor">
<OrderBy>
<Attribute name="PlantGroup.Name" order="A"/>
<Attribute name="TSN" order="A"/>
</OrderBy>
</ItemType>
</Root>
70
You must have appropriate access rights for the target plant group to which you want to move
items.
You can move any item type in any folder that is under the Electrical Equipment folder. The
software does not move any control stations, circuits, and so forth that are associated with a
moved item.
If you move an item that has an I/O signal that is in the same plant group as that item, the
software moves the signal with the item to the target plant group. If the signal is in a plant
group that is different from the item's plant group, when you move the item the signal remains
in its original plant group.
If you move a motor with a space heater, the software moves the space heater with the
motor. You cannot move space heaters independently.
If you move a cable, the software also moves its conductors or cable sets. You cannot move
these cable components independently. Also, if you move one cable that is part of a parallel
cable assembly, the software moves all the cables in the assembly.
If you move a junction box or a local panel, the software moves any circuits associated with the
moved item.
You can move a PDB with its associated components, such as buses, cells, and circuits;
however you cannot move those components independently.
You can only move disconnect electrical equipment items that are not associated with any
circuits.
71
Properties Window
The Properties window display is a two-column table that provides the common properties of the
current item tag in the active window (Reference Data Explorer, Electrical Index, Electrical
Engineer) or Tabular Editor. The active items always determine the content of the Properties
window. There can only be one Properties window open. If only one tag is selected in the active
window or in the Tabular Editor, or all tags are of the same type, all the properties of that tag type
are displayed. If the selected items have different values for their common properties, the value
field is blank. For select lists, there is a separating line below which all the available values
appear. You can modify the values for these properties in the Properties window.
At the top of the Properties window is the Properties box, listing all of the selected items. Item
properties can be displayed by locating the appropriate item in the Properties box, as well as by
selecting in the Reference Data Explorer, Electrical Index, Electrical Engineer, Tabular
Editor, or open a single line diagram. If more than one item is selected in the active window, then
the list at the top of the Properties window contains the choice Select Set, and individual items in
the set can be selected from the list.
You can use the Copy Bulk Properties and Paste Bulk Properties buttons to copy properties
from one item to another. This action can be particularly useful when, for instance, changes need
to apply to more than one item.
When you pause your pointer over the buttons on the Properties window toolbar, a ToolTip
appears, giving the name of the button.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
72
You can review and edit item properties in the Tabular Editor too. You can edit the contents of
some cells directly in the table if the corresponding property is not read-only or generated
strictly by a calculation. Or you can click any cell or on the row number to the left of the table
to select an item and edit its properties in the Properties window.
In place of values that include automatically assigned units of measure, you can type any
string preceded by a single quote. This is useful if you do not initially know a specific value
and want to insert a comment instead.
73
The software includes a default set of bulk and brief properties, but you can change those
properties in the Usage box on the Layout tab of the Advanced Table Properties dialog box.
When a URL such as: http://www.google.com?hl=en&q=Intergraph is entered in a
Description field, the software will not recognize it as a URL because it contains special
characters (?, & and =). The user has to manually replace special characters with encoded
characters as shown.
Special Character
Replace With
3F
3D
&
26
74
Alphabetic
Categorized
Display Null
Displays a null value in blank properties that currently contain no value.
This option help avoid confusion between empty cells and those containing a zero.
to display by categories.
3. You can display only brief properties by clicking Show Brief Properties
4. You can display a null character in empty properties cells by clicking Display Null
When you point to a button on the Properties window toolbar and pause over it, a ToolTip
displays the corresponding command.
You create categories and assign properties to them in the Data Dictionary Manager.
75
76
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You access this dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the item. For full details of the properties, see the
appropriate dialog box topic.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
77
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You access this dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the item. For full details of the properties, see the
appropriate dialog box topic.
When you copy a reference item, the software copies the item properties, except for the Item
tag property, which follows the item naming convention.
For an item that includes sub- items, such as a typical circuit with internal components, the
software copies the sub-items as well. In this case, the sub-items are the circuit components.
For some items, you can edit properties in either the Properties window or on a Common
Properties dialog box. You can click the Common Properties command on the shortcut
menu for an item to open a dialog box on which you can edit the most commonly used
properties for the item. For full details of the properties, see the appropriate dialog box topic.
If you edit a profile, a typical circuit, or a control station in the Reference Data Explorer, the
software uses the latest update when you next apply options to a project item. For example, if
you modify the components of a typical circuit that already has a reference from a motor, the
software does not automatically update the change in the typical circuit connected to the
motor. The software updates the change only when you next apply a typical circuit or a profile
to the motor.
Duplicate an Item
You can duplicate an item in the Reference Data Explorer or Electrical Index. This method is
advantageous when you have items that include a hierarchy of sub-items, in which case the
software duplicates the sub-items including the parent items.
1. In the Reference Data Explorer or the Electrical Index, expand the folder hierarchy by
clicking the + icons or by double-clicking the folders.
2. Right-click an item, and on the shortcut menu, click Duplicate.
3. Accept the default item tag that is based on the naming convention for the item type, or type
your own item tag according to the naming convention.
For more details of naming convention settings, see Using Naming Conventions (on
page 65).
78
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you duplicate the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You access this dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the item. For full details of the properties, see the
appropriate dialog box topic.
When you duplicate an item, the software copies only the item properties, except for the Item
tag property, which follows the item naming convention. The software does not copy
associated items such as cables, typical circuits, or control stations, nor does it duplicate
associations to feeder circuits.
For an item that includes sub- items, such as a circuit with internal components, the software
duplicates the sub-items as well. In this case, the sub-items are the circuit components.
Rename an Item
This procedure explains how to rename an existing item in the Electrical Index, Electrical
Engineer, or Reference Data Explorer.
1. In the Reference Data Explorer, the Electrical Index, or the Electrical Engineer, expand
the folder hierarchy by clicking the + icons or double-clicking the folders.
2. Select an item and open the Item Tag dialog box by doing one of the following:
Right-click the item, and on the shortcut menu, click Rename.
Press F2.
3. Type a new item tag according to the naming convention.
For more details of naming convention settings, see Using Naming Conventions (on page
65).
If you rename a profile, a typical circuit, or a control station in the Reference Data
Explorer, the software uses the new name if there is a reference to one of these items from a
project item. For example, if you change the name of a typical circuit that already has a reference
from a motor, the software automatically updates the name of the typical circuit associated with
the motor.
Delete an Item
You can delete items in the Reference Data Explorer or the Electrical Index. When you delete
items, the software deletes them from the database.
1. In the Reference Data Explorer or the Electrical Index, expand the folder hierarchy by
clicking the + icons or by double-clicking the folders.
2. Right-click the item that you want to delete, and on the shortcut menu, click Delete.
3. At the prompt, click Yes to confirm the deletion.
You can delete only items that do not have associations to other items. For example, you
cannot delete a power distribution board associated with loads unless you first dissociate the
loads.
79
If you select more than one item for deletion, any failures to delete items are recorded in the
Batch Deletion log file. For the procedure for creating and viewing the log file, see Generate
Error Log Files (on page 34).
Precondition
Result
Profile
Typical circuit
Typical control
station
Typical
schematic
Typical block
You have dissociated the block The software deletes the typical block
from all schematics to which it only.
belonged.
Typical motor
You have dissociated the motor The software deletes the motor and
from all profiles to which it
any space heater associated with the
belonged.
motor.
80
Item
Precondition
Result
Motor
None.
Static load
None.
Precondition
Result
Converting
equipment
None.
Panel
Panel circuit
None.
81
If the Create item based on profile box contains the text No default profile exists, the
software does not create any items when you click Apply. You must select a profile first.
If the profile contains a reference item, the software populates new items that you create by
this method with values copied from the reference item.
Electrical Motors
The following sub-section contains topics related to the creation and management of electrical
motors.
82
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new
electrical motor.
The Electrical Motor Common Properties dialog box shows the most commonly used
properties. You access this dialog box by clicking the Common Properties command on the
shortcut menu or you can specify in the preferences to open the dialog box directly when you
create a new electrical motor.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
When you add a motor with a space heater, the heater appears as a sub-item of the
motor. The motor symbol includes an indication that it has a space heater
. If you
subsequently delete the motor, the software deletes the heater also.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
For a motor without a heater, you can add a heater by right-clicking the motor, and on the
shortcut menu, clicking New Heater.
You can delete a heater from a motor by selecting the heater, and on the shortcut menu,
clicking Delete.
2. Right-click the desired motor and click Common Properties to open the Electrical Motor
Common Properties dialog box.
3. Edit the data as needed on each tab. Note that an asterisk beside a property name indicates
required data.
For full details of the most commonly used properties, see the Electrical Motor Common
Properties dialog box (on page 691). Also, you can use the Properties window or the Tabular
Editor to edit these properties.
For full details of the properties that the software uses in power calculations and the formulas
the software uses to calculate power requirements, see Electrical Calculations (on page 569).
For full details of the most commonly used properties, see the Electrical Motor Common
Properties dialog box (on page 691). Also, you can edit these properties and additional
properties on the Properties window or on the Tabular Editor.
83
84
The Demand factor value affects the following properties of electrical motors:
Brake power.
Power factor and efficiency at demand.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you duplicate an
electrical motor.
The Electrical Motor Common Properties dialog box shows the most commonly used
properties. You access this dialog box by clicking the Common Properties command on the
shortcut menu or you can specify in the preferences to open the dialog box directly when you
duplicate an electrical motor.
When you duplicate a motor, the software copies only the item properties, except for the Item
tag property, which follows the motor naming convention. The software does not copy
associated items such as cables, typical circuits, or control stations, nor does it duplicate
associations to feeder circuits.
When the motor has a space heater, the software duplicates the space heater as well.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the item type. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
85
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new item.
The Static Load Common Properties dialog box shows the most commonly used
properties. You access this dialog box by clicking the Common Properties command on the
shortcut menu or you can specify in the preferences to open the dialog box directly when you
create a new item.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
86
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the item type. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. On the Other Electrical Equipment Common Properties dialog box, edit the item
properties as desired. Note that an asterisk beside a property name indicates required data.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new item.
The Other Electrical Equipment Common Properties dialog box shows the most commonly
used properties. You access this dialog box by clicking the Common Properties command
on the shortcut menu or you can specify in the preferences to open the dialog box directly
when you create a new item.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
87
88
Accounting for Space Heaters and Auxiliary Contacts in Batch Load Associations
Space heaters connected through the main equipment circuit auxiliary contacts are shown and
taken into account in the batch load association of the bus that feeds the auxiliary contact and not
the main equipment bus.
On the Batch Load Association dialog box, you can now select space heaters as regular loads
even if they are connected through auxiliary contacts.
To see various recommended scenarios for working with space heaters and auxiliary
contacts, see Suggested Workflows for Space Heaters and Auxiliary Contacts (on page 90).
When designing electrical terminations of space heaters, to terminate the auxiliary contact
with a space heater or any other electrical equipment item, terminate the cable conductors to
the terminal strip of the circuit where the auxiliary contact is located.
If you are generating a cable schedule report for a cable that is connected to an auxiliary
contact, the cable schedule report will display the full connection path:
PDB > Bus > Cell > Circuit > Circuit internal disconnect electrical equipment > Auxiliary
contact
Or
Stand-alone disconnect electrical equipment > Auxiliary contact
89
When performing bus load association and assigning a load to another bus on the Cached
Loads tab of the Bus Load Association dialog box, the software checks if the selected load
is associated with a heater that is connected through an auxiliary contact that is fed from the
same circuit as the selected load. If the software detects such a heater, it will prompt you to
move the associated circuit together with the load. If you click Yes, the software will move the
load and its heater together with the associated circuit to another bus. If you click No, the
software will only move the selected load without moving the heater or the circuit. In this case,
you will have to move the associated heater manually.
90
91
92
The design can include a cable between the input of the auxiliary contact and its feeding
circuit as shown above. Alternatively, you can design it without a cable. In this case, all the
connections are made internally in the PDB.
To create the design shown above, do the following:
1. In the Electrical Index or cable block diagram, create two separate electrical branches in the
same PDB:
A branch for the main motor.
A branch for the feeder to supply the power to the auxiliary contact.
93
94
In this design, the power for the space heater is provided by either an internal connection
taken from one of the phases or by using an internal transformer that converts the three-phase
400v of the main bus to lower, single-phase voltages. The software shows these internal items as
auxiliary graphics that are contained in the symbol of the auxiliary contact.
To create the design shown above, do the following:
1. In the Electrical Index or cable block diagram, create one electrical branch for the main
motor.
2. Associate the space heater with the output of the auxiliary contact by dragging the auxiliary
contact under the main circuit to supply the power to the auxiliary contact and space heater
(through the auxiliary contact).
A branch for the feeder to supply the power to the auxiliary contact.
There is no cable connecting the auxiliary contact and its feeder circuit because
both the auxiliary contact and its feeder circuit are in the same PDB.
95
For detailed information about the creation and association of electrical items, see the topics in the
Managing Space Heaters and Their Power Supplies section in the table of contents as well as
the topics listed below:
Create a Space Heater (on page 97)
Create an Auxiliary Contact (on page 109)
Working with Smart Data and Auxiliary Graphics in a CBD (on page 320)
Create an Electrical Association (on page 186)
Rules for Associating Electrical Equipment (on page 187)
Change an Existing Electrical Association (on page 191)
96
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new
electrical motor.
The Static Load Common Properties dialog box shows the most commonly used
properties. You access this dialog box by clicking the Common Properties command on the
shortcut menu or you can specify in the preferences to open the dialog box directly when you
create a new electrical motor.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
After adding a space heater to a motor, the space heater appears as a sub-item of the
motor. The motor symbol includes an indication that it has a space heater
. If you
subsequently delete the motor, the software deletes the heater also.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
97
98
Create a Generator
You can include generators to provide power supply for your utility.
1. In the Reference Data Explorer or the Electrical Index, expand the folder hierarchy
Electrical Equipment > Generators.
2. Right-click the Generators folder, and then click New.
3. Accept the default item tag or type your own item tag for the generator.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
generator. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. Edit the generator properties in the Properties window as required.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the
generator.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
99
After generating an SLD, the diagram will display the neutral earthing branch connected to a
non-power connection point of the generator.
If you are using custom symbols for your generators in SLDs, make sure that they have an
additional non-power connection point. Alternatively, you can use one of the symbol
provided in the shipped data.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
offsite power supplies. For more details of naming convention settings, see Using
Naming Conventions (on page 65).
4. Edit the generator properties in the Properties window as required.
100
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create an offsite
power supply.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the battery bank. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. Edit the battery bank properties in the Properties window as required.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create the battery
bank.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
Converting Equipment
The following section contains topics related to the management of various types of converting
electrical equipment.
Battery Chargers
Other Converting Equipment these includes devices such as rectifiers.
Transformers You can include various transformers in your project wherever you need to
step-down or step-up the voltage. You can create transformers with two or three sets of
windings. For more information, see Create a Transformer (on page 102).
Uninterrupted Power Supplies (UPSs)
Variable Frequency Drives (VFDs)
Current Limiting Reactors
For information on how to define a converting equipment item as a consumer, see Define
Converting Equipment as Consumers (on page 104).
101
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the item type. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. On the Converting Equipment Common Properties dialog box, edit the item properties as
required. Note that an asterisk beside a property name indicates required data.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new item.
The Converting Equipment Common Properties dialog box shows the most commonly
used properties. You access this dialog box by clicking the Common Properties command
on the shortcut menu or you can specify in the preferences to open the dialog box directly
when you create a new item.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
Create a Transformer
1. In the Reference Data Explorer or the Electrical Index, expand the folder hierarchy
Electrical Equipment > Converting Equipment > Transformers.
2. Right-click the Transformers folder, and then click New 2-winding Transformer or New
3-winding Transformer.
3. Accept the default item tag or type your own item tag for the transformer.
102
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the transformer. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new
transformer.
The Converting Equipment Common Properties dialog box shows the most commonly
used properties. You access this dialog box by clicking the Common Properties command
on the shortcut menu or you can specify in the preferences to open the dialog box directly
when you create a new transformer.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
The secondary windings of a transformer are sub-items of the transformer. The properties of
the secondary windings appear separately in the Properties window. To view these
properties, expand the icon that represents the transformer
and select the icon
representing the desired secondary winding .
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
beside
On the Find dialog box, the software retrieves all the existing resistors regardless of
whether they have or have not been associated with transformers. Make sure that you
select an appropriate resistor that has not been associated yet.
If necessary, define a new resistor.
8. Click Apply to accept the values.
103
You must specify a separate grounding cable and resistor for each winding, if needed.
To enable the display of grounding cable and resistor data in an SLD, you must use a
transformer symbol that includes macros for these items. To do this, right-click on the
transformer, and on the shortcut menu click Associate custom symbols. On the Associate
Custom Symbols dialog box, under Document Type, select Single Line Diagrams, then
navigate to the symbol folder and select the appropriate file.
104
SECTION 7
In This Section
Power Distribution Boards and Buses ........................................... 105
Create Disconnect Electrical Equipment ....................................... 108
Metering Equipment ....................................................................... 110
Designing Power Distribution Boards ............................................ 114
Using Dual Source Power Supplies ............................................... 119
Using Transfer Switches ................................................................ 121
Working with Circuits ..................................................................... 122
105
In the Reference Data Explorer, you can type a string of up to 80 characters in length.
In the Electrical Index, the name must be in accordance with the naming convention for
the PDB. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. Design the PDB structure if you need to do it at this stage. For details, see Design a Power
Distribution Board Structure (on page 115).
You can also create a power distribution board by dragging a typical PDB from the Reference
Data Explorer to the Electrical Index.
You can customize the appearance of how the PDB appears on your SLD drawings. The
options available include line style, width, and color, position of SmartText and so forth. For
more details, see Creating Symbols in the Catalog Manager User's Guide, under Catalog
Manager, Working with Symbols, Creating Symbols.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
Create a Bus
This procedure explains how to add a new bus to a power distribution board.
1. In the Electrical Index or the Reference Data Explorer, expand the folder hierarchy
Electrical Equipment > Power Distribution Equipment > Power Distribution Boards.
2. Click a PDB to expand its folder hierarchy.
3. Right-click the Buses folder and click New.
4. Accept the default item tag or type your own item tag for the bus.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the bus. For more details of naming convention settings, see Using Naming Conventions
(on page 65).
5. Edit the bus properties as required in the Properties window.
You can also create a dual bus. Create buses and then connect them using a bus tie. For
information about bus tie creation, see Associate Bus Riser Circuits with Coupler Circuits (on page
196).
106
You can delete only items that do not have associations to other items. For example, you
cannot delete a power distribution board associated with loads unless you first dissociate the
loads.
If you select more than one item for deletion, the software records any deletion failures in the
Batch Deletion log file. For the procedure for creating and viewing the log file, see Generate
Error Log Files (on page 34).
107
Precondition
Power distribution
board
Bus
Cell
Circuit
Circuit internal
Result
108
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the item type. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
5. On the Disconnect Electrical Equipment Common Properties dialog box, edit the item
properties as required. Note that an asterisk beside a property name indicates required data.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new item.
The Disconnect Electrical Equipment Common Properties dialog box shows the most
commonly used properties. You access this dialog box by clicking the Common Properties
command on the shortcut menu or you can specify in the preferences to open the dialog box
directly when you create a new item.
You can also edit the most commonly used properties and additional properties in the
Properties window or on the Tabular Editor.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
You can create only one auxiliary contact under a given type of disconnect electrical
equipment.
You cannot create auxiliary contacts under metering equipment.
1. In the Electrical Index or Reference Data Explorer, expand the following hierarchy:
Power Distribution Equipment > Disconnect Electrical Equipment.
Also, you can create an auxiliary contact under any circuit in the Electrical Index.
However, the software does not allow you to create more than one auxiliary contact under a
specific circuit. That is, if you try to create an auxiliary contact under a circuit which already
has an auxiliary contact, the software displays a message informing you that this operation is
not allowed.
2. Expand the hierarchy further until you see the individual child items of disconnect electrical
equipment.
3. Right-click an appropriate child item of the desired disconnect electrical equipment (for
example, a contactor) and then click New.
In the Reference Data Explorer, you can type a string up to 80 characters long.
In the Electrical Index, the name must be in accordance with the naming convention for
the item type. For more details of naming convention settings, see Using Naming
Conventions (on page 65).
4. In the Properties window, enter the item properties as required.
On the Preferences dialog box, General tab, under Open after creating or duplicating
an item, you can specify whether to open the Item Tag dialog box when you create a new item.
109
Metering Equipment
SmartPlant Electrical allows you to create equipment for measuring electrical parameters such as
voltages and currents. The software allows you to create voltmeters, ammeters, and
multimeters. For measuring large voltages and currents, you can also create measuring
transformers for these parameters. You create standard meters and measuring transformers in
the Reference Data Explorer as standalone items or as part of reference circuits.
In addition, you can create protection relays with various functions for protecting the circuit.
In the Electrical Index, you can locate metering equipment at any level under a PDB. You can
display metering equipment in single line diagrams.
110
Create Meters
This procedure explains how to create ammeters, voltmeters, or multimeters. You can use these
meters to measure the outputs of measuring transformers.
1. Do one of the following:
In the Reference Data Explorer, expand the hierarchy Power Distribution Equipment
> Disconnect Electrical Equipment > Metering Equipment.
In the Electrical Index, expand the folder hierarchy by clicking the + icons or by
double-clicking the folders, and then select an item according to the following step.
2. Do one of the following:
Under the Electrical Equipment folder, navigate to a load, an item of converting
equipment, or another electrical item, and display the Metering Equipment folder for that
item.
Expand the hierarchy Power Distribution Equipment > Power Distribution Boards
and select a Metering Equipment folder under a power distribution board, a bus, a cell,
or a transfer switch.
Expand the hierarchy Power Distribution Equipment > Power Distribution Boards
and select a circuit.
Right-click the selected item, and then click one of the following:
New Ammeter.
New Voltmeter.
New Multimeter.
3. Select the new item that you have created, and in the Properties window, type a numeric
value for the Tag Sequence No property.
The Tag Sequence No property determines the positioning of the meter on the SLD.
To display a meter on an SLD, you need to drag it to the SLD after generation.
4. With the item selected, do one of the following:
Click Edit > Common Properties.
Right-click the item and on the shortcut menu, click Common Properties.
Press CTRL + F2.
5. On the Metering Equipment Common Properties dialog box, enter the desired values for
the item.
6. For a multimeter, click the Ranges tab to specify the meter functions and desired range of
values for each function.
If the parent folder contains custom folders, the created item is placed in the root folder. If
the items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the item
from the root folder to the All Items folder.
111
112
5.
6.
7.
8.
9.
The Tag Sequence No property determines the positioning of the measuring transformer
on the SLD.
To display a protection relay on an SLD, you need to drag it to the SLD after generation.
With the protection relay selected, do one of the following:
Click Edit > Common Properties.
Right-click the protection relay and on the shortcut menu, click Common Properties.
Press CTRL + F2.
On the Metering Equipment Common Properties dialog box, enter appropriate values for
the protection relay.
Click the Functions tab to specify the relay functions that you want to include.
Click Add for each new function that you want to add to the relay and from the Find dialog
box, select the required relay function.
Modify the function properties if desired.
In Data Dictionary, you can add user-defined properties for your protection relay functions. For
details, see the Data Dictionary documentation.
Modifying the function properties does not affect the default values for that function.
If the parent folder contains custom folders, the created item is placed in the root folder. If
the items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the item
from the root folder to the All Items folder.
113
114
For more details about the values needed for PDB structures, see Power Distribution Board
Structure Dialog Box (on page 759).
If you need to change the physical structure of a PDB that is already associated with a PDB
layout, the software does not allow you to make any changes to those parts of the structure
that are assigned to cells. For example, if you want to delete a section or a row where you
have already placed a cell, you have to open the pertinent PDB layout drawing and remove the
cell. Only then can you reopen the Power Distribution Board Structure dialog box and
delete that section or row.
115
116
The software represents the cells using a default symbol and a macro that specifies the
cell name.
You can customize your own PDB and cell symbols or use the default symbols provided
by the software.
The software determines the symbol size automatically based on the cell size.
You can specify the cell names based on the physical location of the cells within the
PDB. The cells inherit and store in their properties all the spatial coordinates related to
their locations. You can use these coordinates when defining the cell naming
conventions.
When placing a cell in the drawing grid, the origin point of the placed symbol is always the
upper left corner of the upper grid row taken by the symbol.
Make sure that you synchronize the size of your cell symbols with the size of the
cells. When creating cell symbols, the symbol size has to be defined according to the
original physical size of the cell. The software scales the macro fonts and x and y
coordinates according to the scale factor defined on the Document Properties dialog
box. This way you will avoid a situation in which the software places the macro
incorrectly or the macro size exceeds the size of the cell units.
10. Save the drawing.
A PDB can have only one structure and be associated only with one PDB layout drawing.
Once you placed a cell in the grid, moving a cell to another place in the drawing grid is possible
if that part of the grid is vacant, that is there are no other cells assigned to that part of the
grid. To move a cell, click Edit > Move Cell and then drag the cell to another place in the grid.
To remove a cell from the layout drawing, select a cell in the layout drawing and then click Edit
> Remove Cell. Removing a cell from a PDB layout drawing does not delete the cell from
your plant. Once you remove a cell from a PDB layout, the software dissociates the cell from
the drawing and the place that used to occupy in the grid becomes available for other cells. If
no other cells exist, you can delete the vacant rows from the PDB structure. For details, see
Design a Power Distribution Board Structure (on page 115).
Save the PDB layout drawing in the file format that you require.
Deleting a PDB layout drawing, does not dissociate the PDB from its layout. Furthermore, the
software still retains the association of the cells with their locations in the PDB layout. The
PDB layout drawing serves only as a means to show the PDB layout in a graphical
way. Therefore, if you want to redesign the structure of a PDB, open the associated PDB
layout drawing and remove all the cells.
You can open an existing PDB layout drawing for a specific power distribution board by
right-clicking a PDB in the Electrical Index and then clicking Associated Drawings.
The scale of PDB layout drawings is limited to 1:100.
117
Create a Cell
This procedure shows how to create a cell and manually define its size. Note that you must
define the cell size prior to assigning it to a specific location in a PDB layout.
1. In the Electrical Index, expand the folder hierarchy Electrical Equipment > Power
Distribution Equipment > Power Distribution Boards > Buses.
2. Right-click a bus and click New Cell.
3. Accept the default item tag that is based on the naming convention for the cell, or type your
own item tag according to the naming convention.
For more details of naming convention settings, see Using Naming Conventions (on
page 65).
4. Edit the other cell properties in the Properties window as required.
118
It is essential that you define the cell size. This definition is required for PDB layout
design. You can define the cell size manually or perform a procedure that will automate the
cells sizing every time you create a cell. To define the cell size manually, in the Properties
window, under Identification, type an appropriate value for Cell Height in Units and Cell
Width in Units. Alternatively, you can type a Space Factor. The Cell Height in Units value
equals double of the Space Factor value. The Space Factor value that you can type can
only be incremented by 0.5, for example 0.5, 1, 1.5, 2, 2,5, and so forth.
For information on how to perform the procedure that automates cell size definition, see
Automate Cell Size Definition (on page 119).
Now you can place this cell in a PDB layout drawing by dragging it from the Electrical Index to
an appropriate place in the layout grid. For details, see Design a PDB Layout (see "Design a
Power Distribution Board Layout" on page 116).
We recommend that you redefine the cell naming conventions and use the available spatial
properties of cells so that you can fully take advantage of the PDB layout functionality. Also
note that the Row Name and Section Name cell properties are no longer in use.
Loads that are connected to circuits for which the circuit mode value is Disconnected appear
in bus load summaries, but the software does not take those loads into account in the total
load calculation.
If a load is connected to a dual power source that originates from the same feeding upstream
bus, the software does not count such a load twice and accounts for it correctly in load
summaries and other load calculations.
For batch load association calculations, a load connected to a circuit in Disconnected mode
is only displayed in the Associated loads data window of the Bus Load Association dialog
box. Such a load does not appear in the Calculation results group box. There is no need to
set the circuit mode as Connected or Disconnected for loads that have an alternative power
source. The software automatically sets the circuit mode of these loads to Disconnected.
119
In the Electrical Engineer, the software places a visual indication '(#)' beside the names of
the load and the feeder cable where they appear in the alternative power supply branch.
You can change the alternative power source by right-clicking the feeder cable in the
alternative power supply branch and clicking Select Alternative Power Source.
If the load is only connected to an alternative power source, any drag-and-drop operations that
you perform in the Electrical Engineer affect the primary power source only.
120
You cannot select transfer switches as designated PDBs on the Feeder tabs of the Common
Properties dialog boxes for loads, converting equipment, and so forth.
The software includes the name of a transfer switch on the Feeder tab for a connected load as
part of the feeder path.
After you create a transfer switch, you can add cells and circuit internals to it.
121
Create a Circuit
This procedure shows how to create a new circuit in the Electrical Index.
1. In the Electrical Index, expand the folder hierarchy Electrical Equipment > Power
Distribution Equipment > Power Distribution Boards > Buses.
You can also create a circuit by dragging a typical circuit from the Reference Data
Explorer to the Electrical Index.
2. Right-click a bus and on the shortcut menu, select one of the following:
New Feeder Circuit
New Incomer Circuit
New Coupler Circuit
New Bus Riser Circuit
3. Accept the default item tag that is based on the naming convention for the circuit, or type your
own item tag according to the naming convention.
For more details of naming convention settings, see Using Naming Conventions (on
page 65).
4. Edit the circuit properties as required on the Circuit Common Properties dialog box.
122
You can associate the internal components of a circuit with relevant lookup tables that contain
appropriate data. On the Circuit Common Properties dialog box, click the Associate Items
tab. Then, in the Circuit internals data window, under Lookup Table, click and select the
lookup table that you require. You will then be able to apply this associated lookup table to a
project circuit when you run the Apply Lookup Tables feature on the Apply Options dialog
box to propagate the lookup table data to the circuit internal components.
You cannot change the circuit function in the Properties window. If you need to change the
function of an existing circuit, create a new one then delete the circuit for which the function is
not appropriate.
You cannot add a circuit that has a function type that does not match the circuit function of the
existing circuits belonging to the same bus or cell.
If the circuit was previously populated with typical circuit data, the software clears the
reference to the typical circuit.
If the circuit is already associated with a load, the software clears the reference to the typical
circuit.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
You can assign a typical circuit to a bus, in which case the software adds to the bus a
new circuit containing components that are derived from the typical circuit.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Typical Circuit tab.
Select Enable typical circuit.
Beside the Typical circuit box, click Find.
On the Find dialog box, click Find Now to display the available typical circuits that match the
type of circuit you have selected to assign the data to, such as feeder or incomer.
From the list of typical circuits, highlight the typical circuit that you want to assign.
Click OK.
If you apply a typical circuit to more than one circuit in the Electrical Index, the software
applies the typical circuit only to those circuits of the same type as the typical circuit.
If you apply a typical circuit to a circuit that already has associated components, the software
prompts you as to whether you want to replace the existing components with components
belonging to the typical circuit.
If you apply a typical circuit that includes associated reference cables, the software creates
project cables from them and adds the project cables to the circuit with the To sides of the
cables associated with the circuit.
You cannot assign a typical circuit to a circuit that is already associated with a load.
123
124
The circuit function type must match the function type of the bus or cell. For example:
incomer or feeder.
You can relocate a circuit within a specific bus only; you cannot move a circuit to a different
bus.
SECTION 8
125
When you apply data using a lookup table, the software can overwrite existing data. Since
this process is not reversible, you should proceed with great care.
It is good practice not to include calculated properties in lookup tables. For example, if the
Supply AC/DC Flag property for a motor is set to DC, and you try to select a value for the
Frequency property, you cannot apply this value and the software rejects the operation. You
must first set Supply AC/DC Flag to AC, and only then you can apply the lookup table value
for the Frequency property to the motor.
1. In the Electrical Index, expand the folder hierarchy by clicking the + icons or by doubleclicking the folders.
2. Navigate to the folder for the desired equipment type and do one of the following:
Expand the folder and select an item from the list.
Click the folder, and in the list view pane, hold CTRL while you select more than one item.
You can also select more than one item by selecting a subset of item tags in the Tabular
Editor.
3. Click Tools > Apply Options.
4. On the Apply Options dialog box, click the Lookup Table tab.
126
3.
4.
5.
6.
7.
8.
9.
10.
You can apply a typical circuit to all loads, all converting equipment items, and circuits.
You can also select more than one item by selecting a subset of item tags in the Tabular
Editor.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Typical Circuit tab.
Select Enable typical circuit.
Beside the Typical circuit box, click Find.
On the Find dialog box, click Find Now to display the available typical circuits.
From the list of typical circuits, highlight the typical circuit that you want to assign to the
equipment.
Click OK.
Under Apply to, select one of the following options according to the rule the software uses to
apply the typical circuit:
All items - Applies the typical circuit to all the selected items.
Items with no typical circuit - Applies the typical circuit only to items without an existing
typical circuit. Use this option to add a typical circuit only to new items among the items
that you selected.
Items with a different typical circuit from the selection - Changes the typical circuit of
the selected items to the current typical circuit. Use this option to add a typical circuit to
items with a modified typical circuit definition.
Items with the same typical circuit as the selection - Updates an existing typical circuit
for the selected items.
127
If you apply a typical circuit to an item that is already associated with a circuit, the software
adjusts the components of the circuit to match the typical circuit specified by the item.
If you apply a typical circuit that includes associated cables to a circuit, the software creates
cables in the project and associates their 'To' sides with the circuit.
If you modify the components of a typical circuit that already has a reference from an item, the
software does not update the change in the reference until you next apply a typical circuit or a
profile to the item.
If the item that you are applying the typical circuit to is connected to a feeder circuit, the system
replaces the circuit so that it matches the applied typical circuit as specified in the profile.
If the item is connected to feeder equipment other than a circuit (such as a variable frequency
drive, a transformer, or a battery bank), the software does not apply the typical circuit.
If more than one item is connected to the same circuit, the software changes the last applied
typical circuit for all the items.
You can clear the typical circuit of an item that is not connected to any circuit by selecting
Clear the last applied typical circuit.
You can apply a typical circuit on a circuit, provided that the circuit has no equipment
connected to it.
3.
4.
5.
6.
7.
8.
9.
10.
You can also select more than one item by selecting a subset of item tags in the Tabular
Editor.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Control Station tab.
Select Enable control station.
Click Add.
On the Find dialog box, click Find Now to display the available control stations.
From the list of control stations, while holding CTRL, highlight each control station that you
want to associate with the item.
Click OK.
Under Apply to, click All items.
If required, you can click Items with no control station to add control stations only to
items that do not have any existing control stations.
11. Under Action, click Add or Replace to determine how the software deals with control stations
that have the same name as existing control stations. This option applies only if you click All
items.
128
You can apply a typical control station to a load, converting equipment item, disconnect
electrical equipment item, a generator, and a battery bank.
You can view the control stations associated with an item of electrical equipment by selecting
Common Properties on the shortcut menu for the item, and on the dialog box that opens,
selecting the Controls & Signals tab.
If you select a reference control station that has one or more associated control cables, the
software creates these cables in the control station that you add to the project item.
If you apply control stations to one or more items that are connected to circuits, the software
associates the control station cables (instrumentation and control) with the circuits
automatically when you select the appropriate Options Manager setting. If you do not use the
setting, you need to make the association manually. For details, see Associate Control
Station Cables with Equipment Circuits (see "Associate Cables of Control Stations with
Equipment Circuits" on page 197).
If you modify the components of a reference control station that already has a reference from
an item, the software does not update the change in the reference until you next apply a profile
to the item.
129
If you modify the components of a typical schematic that already has a reference from an item,
the software does not update the change in the reference until you next apply a typical
schematic or a profile to the item.
You can assign a new typical schematic or change an assigned typical schematic for an item
at any time.
6.
7.
8.
9.
10.
130
The default profile appears in the Create item based on profile box. You can select a
different profile by performing the following steps.
Beside Create item based on profile, click Find.
On the Find dialog box, click Find Now to display the available profiles.
From the list of profiles, highlight the profile that you want to apply.
Click OK.
Under Apply to, select one of the following options according to the rule the software uses to
apply the profile:
All items Applies the profile to all the selected items.
Items with no profile Applies the profile only to items without an existing profile. Use
this option to add a profile only to new items among the items that you selected.
Items with a different profile from the selection Changes the profile of the selected
items to the current profile. Use this option to add a profile to items with a modified profile
definition.
Items with the same profile as the selection Updates an existing profile for the
selected items.
Applying a profile is a useful way of creating new items and populating large amounts of data
in your project. When you apply the profile, the software automatically applies any definitions
for typical circuits, control stations, typical I/O sets, and lookup tables that you define on the
other tabs of the Apply Options dialog box.
After you apply a profile for which the software creates new items and relations successfully,
the operation may still partially fail, for example if certain values of updated data conflict with a
rule. In such cases, the software displays an error message and records the problem in the
log file.
When you apply a profile, the software replaces all formerly associated items with the items
specified in the current profile including any values that you have modified. The software
assigns new item tags according to the naming convention.
If you apply a profile that contains a reference item to one or more project items, the software
populates the properties of those project items with values copied from the reference item.
If you modify the components of a typical circuit that already has a reference from an item, the
software does not update the change in the reference until you next apply a typical circuit or a
profile to the item.
When an item has associated cables, and you connect the item to a circuit by applying a
profile with a typical circuit, if there is more than one cable, the software associates the free
ends of all the cables to the circuit.
If you apply a profile for a reference motor with a heater to a project motor without a heater, the
software adds a heater to the project motor.
If you apply a profile for a transformer, the software applies the profile only if the reference and
project transformers have the same number of windings and where the Number of
Secondaries property for the project transformer has a value of 1 or 2. If no value appears
for this property, you must type one manually in accordance with the number of secondary
windings in the transformer.
If the item that you are applying a profile to is connected to a feeder circuit, the system
replaces the circuit so that it matches the applied typical circuit as specified in the profile.
If the item is connected to feeder equipment other than a circuit (such as a variable frequency
drive, a transformer, or a battery bank), the software does not apply the profile.
Now you can do one of the following:
To continue with the next step in the recommended workflow for generating a schematic
drawing, see Generate a Schematic (on page 273) or Generate a Multi-Item Schematic (on
page 274).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
131
3.
4.
5.
6.
7.
8.
9.
10.
11.
132
You can also select more than one item by selecting a subset of item tags in the Tabular
Editor.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Typical I/O Sets tab.
Select Enable typical I/O sets.
Beside the Typical I/O sets box, click Find.
On the Find dialog box, click Find Now to display the available set of signals.
From the list of signal sets, highlight the set of signals that you want to assign to the item.
Click OK.
Under Apply to, select one of the following options according to the rule the software uses to
apply the set of signals:
All items - Applies the set of signals to all the selected items.
Items with no typical I/O sets - Applies the set of signals only to items without an
existing set of signals. Use this option to add a set of signals only to new items among
the items that you selected.
Items with a different typical I/O set from the selection - Changes the set of signals of
the selected items to the current set of signals. Use this option to add a set of signals to
items with a modified typical I/O set definition.
Click Apply.
If you modify the components of a set of signals that already has a reference from an item, the
software does not update the change in the reference until you next apply a set of signals or a
profile to the item.
You can assign a new set of signals or change an assigned set of signals for an item at any
time.
4.
5.
6.
7.
8.
9.
10.
11.
12.
To select several loads, click the folder, and then in the list view pane, hold CTRL while
you select more than one item.
Click Tools > Apply Options.
On the Apply Options dialog box, click the Typical CBD tab.
Select Enable typical CBD.
Beside the Typical cable block diagram box, click Find.
On the Find dialog box, click Find Now to display the available typical cable block diagrams.
From the list of the available typical cable block diagrams, select an appropriate typical cable
block diagram that you want to apply to the electrical loads that you selected in the Electrical
Index.
Click OK to return to the Typical CBD tab of the Apply Options dialog box.
Select the Populate empty item properties check box to update only those item properties
that contain null data. When you select this option, the software does not overwrite the data
that is not null.
Clear the check box to leave existing values of the item properties as they are, regardless of
whether they contain null or not null values.
Click OK.
The software does not apply a typical CBD to plant loads in the following cases and
logs the rejection reason in the Apply Typical CBD log file:
If the typical CBD does not contain any typical item that belongs to the same item type as the
electrical item to which you are applying the typical CBD.
If the typical CBD contains more than one typical item that belongs to the same item type as
the electrical item to which you are applying the typical CBD.
If the electrical item is not associated with a bus but the selected typical CBD contains a
reference bus circuit.
If the selected electrical item is already associated with other plant items.
133
134
If you modify the components of a typical schematic that already has a reference from an item,
the software does not update the change in the reference until you next apply a typical
schematic or a profile to the item.
You can assign a new typical schematic or change an assigned typical schematic for an item
at any time.
Panel Management
SECTION 9
Panel Management
You can create the following types of panel in the Electrical Index:
Cabinets Multi-purpose electrical enclosures for various types of equipment. For more
information, see Create a Cabinet (on page 135).
Control Stations - Small cabinets containing low voltage start-stop circuitry used to control a
load at a remote location. For more information, see Create a Control Station (on page 136).
Local Panels - Cabinets containing circuit, equipment, and wiring items, used for example, to
provide switching or isolation close to a motor. For more information, see Create a Local
Panel (on page 137).
Junction Boxes - Containers for electrical connections. For more information, see Create a
Junction Box (on page 137).
In contrast to PDBs (power distribution boards), panels are much smaller in size and do not
contain busbars.
Create a Cabinet
1. In the Electrical Index, expand the folder hierarchy Wiring Equipment > Panels.
2. Right-click the Cabinets folder, and then click New.
3. Accept the default item tag that is based on the naming convention for the panel, or type your
own item tag according to the naming convention.
For more details of naming convention settings, see Using Naming Conventions (on
page 65).
4. On the Cabinet Common Properties dialog box, edit the typical cabinet properties as
required.
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new
cabinet.
You access the Cabinet Common Properties dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create a new cabinet.
135
Panel Management
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you create a new control
station.
You access the Control Station Common Properties dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create a new control station.
If the parent folder contains custom folders, the created item is placed in the root folder. If the
items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re- opening SmartPlant Electrical moves the
item from the root folder to the All Items folder.
136
Panel Management
137
Panel Management
138
SECTION 10
Cable Management
You can create cables in your project for several purposes. SmartPlant Electrical specifies the
following cable categories according to the purpose of the cable: power, control, grounding, and
instrumentation. The software supports compliance with the strict regulations governing cable
definitions by using standard reference cables as a basis for all the cables that you create in your
project. Reference cables contain technical cable data such as voltage rating, ampacity,
resistivity, cable material, and data relating to the construction of the cable. For this reason, you
must initially create all your reference cables in the Reference Data Explorer.
The software allows you to organize your reference cables in families known as cable
specifications. When you select a reference cable to use as a basis for your project cable, you
must select the appropriate cable category and cable specification for the reference cable.
Also, when you size project cables, the software looks for the appropriate reference cable based
on a particular cable specification and conductor arrangement.
You access the Reference Cable Common Properties dialog box by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the cable.
Short circuit sizing calculations for project power cables use data in the Conductors lookup
tables, and this data is then used to select the appropriate reference cable. For this reason,
when you create a new reference cable, it is recommended that you open the Data tab of each
lookup table to ensure that appropriate data related to the reference cable is available, and if it
is not, to add the data on the lookup table.
Do not change any of the values on the Structure tab for the conductors lookup
tables.
139
Cable Management
In the Reference Data Explorer, expand the folder hierarchy Wiring Equipment > Cables.
Expand the desired cable folder: Power Cables, Control Cables, or Grounding Cables.
Right-click the desired cable and on the shortcut menu, click Common Properties.
Enter values for the cable properties on the Reference Cable Common Properties dialog
box according to the available catalog information. You must enter values for those
properties marked with an asterisk.
To enable sizing of a power cable in the project, you should enter values for all the properties
on the General tab.
You can edit the properties of a reference cable as long as it has not been used in the
Electrical Index with any project item or if the reference cable is not part of any existing profile
or control station in the Reference Data Explorer.
Short circuit sizing calculations for project power cables use data in the Conductors lookup
tables, and this data is then used to select the appropriate reference cable. For this reason, if
you change the values of reference cable properties, it is recommended that you open the
Data tab of each lookup table to ensure that appropriate data related to the reference cable is
available, and if it is not, to add the data on the lookup table.
Do not change any of the values on the Structure tab for the conductors lookup
tables.
For more details of naming convention settings, see Using Naming Conventions (on page
65).
If the cable naming convention includes the tag of an associated item and you rename the
associated item tag, you must click Refresh
on the toolbar of the Electrical Index or
the Electrical Engineer to update the cable tag.
If you are creating a number of cables at one time, you may want to stop at this point and
edit the cable properties at a later stage.
4. On the Cable Common Properties dialog box, General tab, select a cable specification.
5. For the selected specification, do one of the following:
If you know the reference cable that you want to use to define your project cable, select
that reference cable from the Reference cable list. The software populates the
properties with data from the reference cable.
If you want to perform sizing for a power cable to determine the most suitable reference
cable, select an option from the Conductor arrangement list.
140
Cable Management
In addition to sizing a non- sized power cable, you can perform cable sizing when you
select a specific reference cable also.
6. Enter other values for the cable properties as required. You must enter values for those
properties marked with an asterisk.
7. Click the Design Data tab and enter routing and cable length data as required.
You must associate each power cable in the Electrical Index with a reference (catalog)
cable. You must therefore first define appropriate reference cables in the Reference Data
Explorer.
You access the Cable Common Properties dialog box (on page 624) by clicking the Common
Properties command on the shortcut menu or you can specify in the preferences to open the
dialog box directly when you create the cable.
You cannot delete a cable that has been assigned to a cable drum.
You cannot assign a project cable to a different cable drum if this cable has been locked to a
drum.
When applying sizing for a power cable, suitable reference cables that the software can select
from must be defined in the Reference Data Explorer.
When changing the reference cable manually or by applying cable sizing, the software copies
all properties relating to cable construction and electrical properties such as ampacity and
resistance. The software does not copy project data such as cable tag and description, nor
data used for sizing such as estimated and design lengths. The software copies other data
such as manufacturer and model only if the value for the project cable is initially empty.
141
Cable Management
Whenever the data of the reference cable that a project cable is associated with is changed,
the Compare to Reference command button in the project cable becomes enabled. This
button opens the Compare Project and Reference Cable Data dialog box (on page 643), from
which you can compare the current project cable properties with the modified reference cable
properties. You can copy the updated reference data to the project cable if required. For a
parallel cable assembly, the software applies the reference data to all the cables in the
assembly.
For full details of the most commonly used properties, see the Cable Common Properties
dialog box (on page 624). Also, you can edit these properties and additional properties in the
Properties window or in the Tabular Editor.
You cannot delete a cable that has been assigned to a cable drum.
You cannot assign a project cable to a different cable drum if this cable has been locked to a
drum.
When defining naming conventions for parallel cables, you can determine where in the cable
tag name you want to include the parallel cable suffix. In Options Manager, on the Define
Naming Conventions dialog box (Options > Naming Conventions > Define), define the
parallel cable suffix in the Segment definitions section. You can move the parallel cable
suffix property up or down the list to set the position of this property in the segment definition.
If you do not select this check box, the suffix for the parallel cables will appear at the end of the
cable tag name.
Delete a Cable
1. In the Reference Data Explorer or the Electrical Index, expand the folder hierarchy Wiring
Equipment > Cables.
2. Expand one of the cable folders: Power Cables, Control Cables, Grounding Cables, or
Instrumentation Cables.
3. Right-click the cable that you want to delete, and on the shortcut menu, click Delete.
4. At the prompt, click Yes to confirm the deletion.
If you select more than one cable for deletion, the software records any deletion failures in
the Batch Deletion log file. For the procedure for creating and viewing the log file, see Generate
Error Log Files (on page 34).
142
Item
Precondition
Result
Reference cable
Project cable
None.
Cable Management
Cable Glands
The topics in this section deal with the management of cable glands.
You can also perform the cable selection in the Tabular Editor.
Click Actions > Cables > Batch Cable Side and Gland Association.
On the From or To cable side, clear the Clear existing gland check box to allow replacement
of existing cable glands for the cables that you select.
Beside the check box, click Find to open the Find dialog box.
Click Find Now.
In the Results data window, select the gland that you want to associate with the cable sides,
and click OK.
From the cable list in the Batch Cable Side and Gland Association dialog box, select the
check boxes beside the cables for which you want to make gland associations
You can select the Speed up association check box to make the process work faster.
However, if the software encounters a problem with one of the cables, the entire association
process is canceled.
10. Click OK.
143
Cable Management
144
Cable Management
6. Click OK to start the synchronization process.
The software synchronizes the glands with the glands of each reference cable that is
associated with the selected plant cables.
The Filter cable criteria options are disabled since you have selected the required cables in
the Electrical Index.
The Show Cable Data button is also disabled as the software populates the Cable data grid
automatically.
145
Cable Management
6. Click OK to start the synchronization process.
Size a Cable
This procedure explains how to size low voltage project power cables. If you associate the cable
with a load, the software uses the load data for sizing, or you can size a cable that is not
associated with a load by typing in data manually. The algorithm that the software uses for sizing
gives a good estimate; however, we recommend that you use specialized cable sizing software for
more accurate results.
SmartPlant Electrical uses algorithms that give a good estimate for cable sizing; however,
we recommend that you use specialized cable sizing software for more accurate results.
1. In the Electrical Index, expand the folder hierarchy Wiring Equipment > Cables > Power
Cables.
You can also select a cable in the Electrical Engineer.
2. Select the desired cable and do one of the following:
Click Edit > Common Properties.
Right-click the cable and on the shortcut menu, click Common Properties.
Press CTRL + F2.
3. On the General tab of the Cable Common Properties dialog box, select the Sizing required
check box.
4. Select a cable specification.
When sizing the cable, the software selects the appropriate reference cable from the
family of cables that you specify under Cable specification and with the value that you
select under Conductor arrangement.
When sizing a multi-core cable, you must first select a reference cable. You cannot size
a multi-core cable if you select a non-sized power as a reference cable. This limitation
is due to the fact that the number of conductors in the project cable is a required
parameter before performing the sizing operation.
5. Click the Design Data tab and enter cable length data.
In the absence of a value for the Design length property, the software uses the value in
the Estimated length box.
6. Click the Sizing Data tab and enter data. For full details of the properties for which you must
enter values for sizing, see Required Data for Cable Sizing (on page 151).
If the cable has an associated load, you can copy load data to the cable by clicking
Refresh Data.
7. Click Perform Sizing to perform the sizing calculation.
8. Click Apply Sizing to select the recommended reference cable or cables for use as the basis
for this cable. The software replaces the currently selected reference cable and updates the
cable properties.
If you want to use the shipped reference data provided with the application, please
validate that these values are appropriate for cable sizing. Note that shipped reference data
is provided to you as uncertified samples only.
146
Cable Management
9. Click Apply to create the sized cable or set of cables in your project.
For full details of the most commonly used properties, see the Cable Common Properties
dialog box (on page 624). Also, you can edit these properties and additional properties in the
Properties window or in the Tabular Editor.
If the cable has an attached load, the software copies the values of sizing data properties from
the load to the cable.
If you have changed the sizing data of a cable to such an extent that the current cable
becomes unsuitable for its function, you need to perform manual resizing of this cable (click
the Perform Sizing button on the Sizing Data tab of the Cable Common Properties dialog
box). The software informs you about this by displaying an appropriate message in the
Calculation information box on the Sizing Data tab of the Cable Common Properties
dialog box and by turning on the Sizing required flag (the software automatically selects the
Sizing required check box on the General tab of the Cable Common Properties dialog
box). For details about the properties that require manual resizing of cables, see Automatic
Switch-On of the Sizing Required Flag (on page 153).
If the software cannot find a single reference cable that is suitable for the needed cable size, it
selects as many parallel cables as required, up to the maximum allowed, which you can
determine in Options Manager. Also in Options Manager, you can select the minimum
conductor size that the software looks for when sizing cables.
You have to resize a power cable if you reassign it to another load or modify the cable
properties. Also, we recommend that you generate a report or use the Tabular Editor to view
which power cables have their Cable Sizing Flag property set to True (same as the Sizing
required check box on the Cable Common Properties dialog box. This enables you to see
the power cables that need resizing.
147
Cable Management
8. Click Apply Sizing to perform the sizing for the selected cables.
When the selected set of cables for batch sizing includes parallel cables, only one tag per
parallel cable assembly appears in the display; however the software performs the operation
for all the parallel cables in each assembly.
The cable data in the Batch Size Cables window is read-only. To update property values,
you need to do so for each cable individually.
For more information on how to define your lookup table, see Example of a Custom Basic
Ampacity Lookup Table (on page 149).
The software does not validate the changes made to custom basic ampacity lookup
tables.
The software does not provide the means to synchronize the lookup tables with the
associated cables.
When copying an electrical network from the Reference Electrical Engineer, the
software does not copy custom installation methods that are defined in the Routing select
list.
You can now use your custom basic ampacity to size cables. For details, see Use Custom Basic
Ampacity to Size Cables (on page 150).
148
Cable Management
149
Cable Management
The Data Tab
150
Cable Management
The software performs sizing by selecting a matching reference cable from the Reference
Data Explorer, so only those reference cables that you created are available for
selection. You should therefore ensure that you create in the Reference Data Explorer all
possible cable types and sizes that you may want to use.
If you have changed the sizing data of a cable to such an extent that the current cable
becomes unsuitable for its function, you need to perform manual resizing of this cable (click
the Perform Sizing button on the Sizing Data tab of the Cable Common Properties dialog
box). The software informs you about this by displaying an appropriate message in the
Calculation information box on the Sizing Data tab of the Cable Common Properties
dialog box and by turning on the Sizing required flag (the software automatically selects the
Sizing required check box on the General tab of the Cable Common Properties dialog
box). For details about the properties that require manual resizing of cables, see Automatic
Switch-On of the Sizing Required Flag (on page 153).
Thermal Sizing
In the thermal sizing step, the software attempts to locate from the Reference Data Explorer the
smallest size reference cable of the specified type and construction, with a de-rated ampacity
equal to or greater than the full load current of the connected load. If the software cannot find a
single cable that meets this requirement, it continues with groups of identical cables in parallel,
from the minimum conductor size, up to the maximum permitted number of parallel cables. You
can specify the minimum conductor size, the maximum permitted number of parallel cables, and
the default suffix naming method in the Options Manager.
The software requires the following data for this stage of the calculation:
Cable specification (General tab) Specifies the family of cables within which the software
looks for a suitable reference cable.
Conductor arrangement (General tab) Specifies the desired conductor arrangement of the
reference cable.
Full load current [FLA] (Sizing Data tab) Specifies the nominal current for a load associated
with the cable, or a value that you type manually.
Routing (Sizing Data tab) Indicates the appropriate routing type for the current cable: InAir,
UnderGround, or some other custom routing type that you define. The option that you select
affects whether the software uses the ampacity value in air, in the ground, or custom basic
ampacity when sizing a cable.
Conformity to standard (Sizing Data tab) Determines the electrical standard, IEC or NEC,
that the software uses. If you select the NEC standard, the software multiplies the full load
current by a factor of 1.25.
151
Cable Management
De-rating factor / Utilization factor / Ambient temp. factor (Sizing Data tab) Specifies
properties that the software divides the nominal current by to obtain the de-rated cable ampacity.
152
Cable Management
short circuit sizing criteria. It is important that the lookup tables contain suitable values to enable
the software to perform the calculation successfully.
Note that after changing the short circuit fault values, the software does not re-calculate
the voltage drop automatically. This is a manual process that you have to start yourself.
The software requires the following data for this stage of the calculation:
Material (General tab) Select the desired material for the current-carrying conductors.
Insulation (General tab) Select the desired material used for insulating the current-carrying
conductors.
Use short circuit cable sizing (Sizing Data tab) You must select this check box to enable the
software to perform the short circuit sizing calculation.
Duration (Sizing Data tab) Type the maximum time for which the cable is expected to
withstand a fault short circuit.
Fault current (Sizing Data tab) Type the maximum current that the cable is expected to
withstand in the event of a short circuit fault current.
The software displays in the Calculation information box the message 'Not found' under
the following conditions: when no reference cable exists corresponding to the cable specification
or arrangement, when there are missing values for ampacity, resistance, or reactance, or when
the number of parallel cables exceeds the specified limit in the Options Manager.
153
Cable Management
Reference Cable Properties
(The properties of the reference cable associated with the plant power cable that needs to be
resized)
Basic ampacity in air
Basic ampacity in ground
Custom basic ampacity
Reactance per unit length
Resistance per unit length
Load Properties
(The properties of the load connected to the plant power cable that needs to be resized)
Conformity to standard
Rated voltage
Number of phases
Supply (AC/DC)
Full load current (FLA)
Locked rotor current (for motors only)
154
The new parallel cables then appear in the Electrical Index under the power cable to which
you have added the parallel cables.
Cable Management
Opening the common properties of a parallel cable shows you the number of existing parallel
cables and the parallel cable list.
If you have defined methods and settings for parallel cables in Options Manager, we do not
recommend that you change these parameters in the middle of a project life-cycle in case
there are no naming conventions for parallel cables.
Replace Cables
This procedure explains how to replace the reference cable used for a group of project
cables. The software replaces the project cables with a standard cable that you previously
defined in the Reference Data Explorer.
1. In the Electrical Index, expand the folder hierarchy Wiring Equipment > Cables.
2. Expand one of the cable folders: Power Cables, Control Cables, Grounding Cables, or
Instrumentation Cables.
3. Click the folder and adjust the size of the panes to view the individual cables in the list view
pane.
4. If required, change the view in the list view pane by clicking View Settings
to toggle
through each view of the items in the list view pane, or click the arrow beside the icon and
select the desired view.
5. Hold CTRL while clicking the cables that you want to replace.
6. Click Actions > Cables > Replace Cables.
7. On the Replace Cables dialog box, do one of the following:
For each cable that you want to replace, select the check box beside the cable name.
Select the Select all check box if you intend to replace all the cables in the list.
8. Select a reference cable to replace in the selected project cables.
If required, select properties under Filter criteria to filter the list of available reference
cables.
The software replaces cables of the same category. For example, you can only replace a
power cable with another power cable.
You cannot replace a cable that has been locked to a cable drum.
The software does not allow you to replace cables in batch mode if the cables that you want to
replace have already been terminated. You can replace a cable manually in the Common
Properties dialog box if the reference cable has the same conductor arrangement as the
cable you want to replace.
The software replaces only the values of the following properties with values from the
reference cable that you select:
Cable Category
Cable Specification
Basic Ampacity in Air
Basic Ampacity in Ground
Reactance
Resistivity
Actual Conductor Size
Additional Conductor Size
Air Ampacity Temperature
155
Cable Management
156
Armor Type
Bending Radius
Conductor Arrangement
Conductor Material
Conductor Size
Inner Insulation Temperature
Insulation Color
Insulation Material
Insulation Temperature rating
Insulation Thickness
Insulation Voltage Rating
Jacket Color
Jacket Insulation Material
Jacket Insulation Temperature
of Additional Conductors
of Conductors
of Conductors in Group
of Sets
Outside Diameter
Overall Shield
Pull Tension
Weight per Length
Cable Formation
Electrical Equipment Class
Electrical Equipment Sub Class
Electrical Equipment Type
Stores Part Number
The software clears the values of the following properties:
Calc Starting Voltage Drop
Calc Voltage Drop Percent
The software retains the values of all other properties of the selected cables.
When the selected cables for replacing include parallel cables, only one tag per parallel cable
assembly appears in the display; however the software performs the operation for all the
parallel cables in each assembly. If descriptions exist for the individual parallel cables, the
software retains those descriptions.
If you want to replace a group of parallel cables generated by the sizing procedure with cables
having a different formation, for the Reference cable property, you must select Non-sized
power cable. Otherwise, you can only replace parallel cables with another group of cables
that have the same formation. For example, you can only replace three parallel cables of 300
m2
2
mm2 (3*300 m ) with another configuration of 3 parallel cables, such as 3*90 mm , 3*(3*25
2
2
mm +1*10 mm ), and so forth.
Cable Management
You can select the Speed up association check box to make the process work faster.
However, if the software encounters a problem with one of the cables, the entire association
process is canceled.
11. Click OK.
157
Cable Management
5. In the Phase arrangement field, select the required phase arrangement.
6. Type in a description, height, and width in their respective fields (optional).
7. At the side of the Reference cable field, click the ellipsis button
to open the Select
Reference Cable dialog box.
8. On the Select Reference Cable dialog box, select the required reference power cable and
click OK.
9. In the Current carrying cores group box, in the Phase label fields, select the label for each
power cable .
The software does not allow you to select the same label for two different power cables in
the cable assembly.
10. In the Neutral cables group box, click Add to open the Select Reference Cable dialog box.
11. On the Select Reference Cable dialog box, select the required cable and click OK.
The values for the selected neutral cable are added automatically to the fields in the
Neutral cables group box.
12. In the Grounding cables group box, click Add to open the Select Reference Cable dialog
box.
13. On the Select Reference Cable dialog box, select the required cable and click OK.
The values for the selected grounding cable are added automatically to the fields in the
Neutral cables group box.
14. Click OK.
158
When defining a neutral or grounding cable, on the Select Reference Cable dialog box, you
can select a power or grounding cable from the Cable category list. Power cables used as
grounding or neutral cables are automatically connected as phase cables and they appear in
the Electrical Engineer. In cable block diagrams and SLDs, the software displays them as
phase power cables belonging to single-core cable assemblies.
After clicking OK on the Common Properties dialog box, the software automatically displays
an expanded view of the cable assembly and adds the assembly's cables to their relevant
folders in the Electrical Index..
When connecting the power connectors (S, T, R) of a single-core cable assembly to an item of
equipment, the software automatically completes the connection of the power connectors after
the first connection has been made to that item. For example, after connecting the S cable to
a motor the software automatically connects the remaining two power cables (T and R) to the
motor. The grounding and neutral cables are not connected automatically and are connected
by the user.
Changing the tag sequence of one of the cables in an assembly affects the tag sequence of all
of the other cables in that assembly.
Making any other change (for example, changing the sizing, routing, and so forth) in the
properties of one of the cables in an assembly that is connected to bus phases affects only
those cables in the assembly that are connected to the phases of the cable assembly.
Changing the properties of a grounding or neutral cable in an assembly affects only that
particular cable.
Cable Management
After clicking OK on the Common Properties dialog box, the software automatically displays
an expanded view of the cable assembly and adds the assembly's cables to their relevant
folders in the Electrical Index..
When connecting the power connectors (S, T, R) of a single-core cable assembly to an item of
equipment, the software automatically completes the connection of the power connectors after
the first connection has been made to that item. For example, after connecting the S cable to
a motor the software automatically connects the remaining two power cables (T and R) to the
motor. The grounding and neutral cables are not connected automatically and are connected
by the user.
Changing the tag sequence of one of the cables in an assembly affects the tag sequence of all
of the other cables in that assembly.
Making any other change (for example, changing the sizing, routing, and so forth) in the
properties of one of the cables in an assembly that is connected to bus phases affects only
those cables in the assembly that are connected to the phases of the cable assembly.
Changing the properties of a grounding or neutral cable in an assembly affects only that
particular cable.
159
Cable Management
160
When connecting the power connectors (S, T, R) of a single-core cable assembly to an item of
equipment, the software automatically completes the connection of the power connectors after
the first connection has been made to that item. For example, after connecting the S cable to
a motor the software automatically connects the remaining two power cables (T and R) to the
motor. The grounding and neutral cables are not connected automatically and are connected
by the user.
Cable Management
When defining a neutral or grounding cable, on the Select Reference Cable dialog box, you
can select a power or grounding cable from the Cable category list. Power cables used as
grounding or neutral cables are automatically connected as phase cables and they appear in
the Electrical Engineer. In cable block diagrams and SLDs, the software displays them as
phase power cables belonging to single-core cable assemblies.
Changing the tag sequence of one of the cables in an assembly affects the tag sequence of all
of the other cables in that assembly.
Making any other change (for example, changing the sizing, routing, and so forth) in the
properties of one of the cables in an assembly that is connected to bus phases affects only
those cables in the assembly that are connected to the phases of the cable assembly.
Changing the properties of a grounding or neutral cable in an assembly affects only that
particular cable.
After dragging a reference single-core cable assembly to the Electrical Index, the software
automatically displays an expanded view of the cable assembly and adds the assembly's
cables to their relevant folders in the Electrical Index. The common properties are also
changed automatically to reflect that the assembly is no longer a reference item.
When connecting the power connectors (S, T, R) of a single-core cable assembly to an item of
equipment, the software automatically completes the connection of the power connectors after
the first connection has been made to that item. For example, after connecting the S cable to
a motor the software automatically connects the remaining two power cables (T and R) to the
motor. The grounding and neutral cables are not connected automatically and are connected
by the user.
Changing the tag sequence of one of the cables in an assembly affects the tag sequence of all
of the other cables in that assembly.
Making any other change (for example, changing the sizing, routing, and so forth) in the
properties of one of the cables in an assembly that is connected to bus phases affects only
those cables in the assembly that are connected to the phases of the cable assembly.
Changing the properties of a grounding or neutral cable in an assembly affects only that
particular cable.
161
Cable Management
Create a Busway
This procedure explains how to create a new busway in the Electrical Index. A busway can be
used in a similar manner to power cable, other than the ability to perform sizing. You can define
the properties of a busway in the Properties window. Also, you can connect a power cable to a
busway if needed.
1. In the Electrical Index, expand the folder hierarchy Wiring Equipment > Busways.
2. Right-click the folder and click New Busway.
3. Rename the busway if you require.
4. In the Properties window, enter values for the desired busway properties.
If the parent folder contains custom folders, the created item is placed in the root folder. If
the items properties match the filter properties of a custom folder a copy of the item is also placed
in the custom folder. Refreshing or closing and re-opening SmartPlant Electrical moves the item
from the root folder to the All Items folder.
162
Cable Management
The software uses the Actual design/installed length value to calculate the cable sizing and
to optimize the cable drum.
The software overwrites the Actual design/installed length value with the Installed length
value after selecting the Cable installed check box. If the new Actual design/installed
length value exceeds the capacity of the drum to which the cable is assigned, the software
displays an appropriate message and prompts you to free some space on the drum by
dissociating some of the cables from the drum.
The installed length is the absolute delta between the Marked length side 1 and Marked
length side 2 values. You do not have to enter Marked length side 1 and Marked
length side 2 values consistently. The software keeps the installed length as a positive
value at all times.
163
SECTION 11
Cable Routing
The cable routing feature allows you to set up a model of the cable routing in your plant. First, you
need to create reference cableway components. These are catalog components for which you
can specify manufacturer's data. The software allows you to specify one of three possible
categories of reference cableway components: trays, conduits, or miscellaneous. You can make
space reservations by defining cableways and segments (the physical conduits) in your plant, and
later associate the segments with reference components. Alternatively, you can specify the
reference components for the segments at the time when you create them. After you define the
cableways and segments in your plant, you can assign cables to specific routing paths, singly or in
batch mode.
The software allows you to create predefined routing paths as a way of specifying physical
relationships between cableways. Predefined cable routing contains cableway segments that
you select and whose order you specify.
You must define a segregation level for the cables you intend to route, as well as for the cableway
segments. Assignment of segregation levels allows you to specify separate groups of cables that
you would not normally route together along the same path, for example, high and low voltage
cables.
A number of reports that come shipped with the software are available to assist you in managing
your cable routing efficiently. These include:
Segment Width Estimate
Cableway Component Material Take-Off
Cableway Segment Schedule
Segment Fill
For more information, see Shipped Reports (on page 382).
165
Cable Routing
All the cables that you select must have the same segregation level and you must define
the actual cable length (estimated length, design length, or routing length) for each cable
that you add to the routing.
When routing cables of more than one category, create a Tabular Editor view for the
desired cables and select from the view the cables that you want to route.
3. Click Actions > Cables > Batch Route Cables.
166
Cable Routing
4. On the Batch Route Cables dialog box, make sure that the Clear routing from selected
cables check box is cleared.
5. In the Cable routing group box, for the first segment, select the cableway and segment from
the relevant lists.
6. For each succeeding segment, click Add, and then select the cableway and segment from the
relevant lists.
7. In the lower data window, do one of the following:
For each cable that you want to assign to the routing path, select the check box beside the
cable tag.
To assign all of the displayed cables, select the Select all check box.
The new cable routing overwrites any existing values under Routing Path.
For a parallel cable assembly, when you define a cable routing for one of the cables, the
software automatically copies the routing to all of the cables in the assembly.
167
Cable Routing
168
Cable Routing
Conventional Method
The Conventional method is based on the physical properties of raceway components. This
method is commonly used and it has a less restrictive approach than the NEC method. For
details on how to set the desired method (Conventional or NEC), see Set The Method For
Segment Fill Validation (on page 172).
169
Cable Routing
Tray Fill Calculation
The software calculates tray segment fill according to the following criteria:
When using the Conventional method, the segment fill calculation is based on the type of
reference tray that you select on the Reference Cableway Component Common
Properties dialog box. The following types of reference trays are available:
Covered tray segment - Applies to trays and miscellaneous cableway components. The
software calculates the total area occupied by the cables assigned to the segment. The
software validates this value by ensuring that it does not exceed the allowed area (the product
of tray width, tray depth and Fill factor), SmartPlant Electrical validates the covered tray fill
segment calculation by area. Furthermore, the software ensures that the outer cable diameter
of any cable does not exceed the tray depth. Note that for covered trays the fill factor value
cannot exceed the value of 1.
Uncovered tray segment - Applies to trays and miscellaneous cableway components. The
software calculates the sum of the outer diameters of the cables assigned to the segment.
SmartPlant Electrical validates this value by ensuring that it does not exceed the product of the
segment width, the fill factor, and the number of layers. The software validates the uncovered
tray fill segment calculation by diameter.
The segment fill calculation is based on tray width or tray area. You select the desired criterion
from the Calculation criteria list on the Cableway Segment Common Properties dialog
box. When selecting the Auto option from the Calculation criteria list, SmartPlant Electrical
calculates the segment fill automatically. The software performs the calculation according to
the type of reference tray that you selected on the Reference Cableway Component
Common Properties dialog box. Selecting the Covered check box instructs the software to
calculate the segment fill according to the Area criterion. If you do not select this check box,
SmartPlant Electrical performs the calculation according to Width.
For details on how to set the segment fill calculation criterion, see Set the Segment Fill
Calculation Criterion (on page 172).
170
For conduits, the fill factor value cannot exceed the value of 1.
You need to define cable diameter and weight per unit length for each associated reference
cable by entering the desired values in the Reference Cableway Component Common
Properties dialog box.
When performing validations based on cable diameter, the software assumes that the cables
are laid side-by-side. Therefore the software does not allow for cables that can pass along the
interstices between larger cables.
Cable Routing
NEC Validation Method
The NEC method is based on given space factors. Unlike the Conventional tray segment
validations, the NEC method does not allow flexibility like the Conventional method regarding tray
segment fill validation. NEC dictates the fill requirements for various cases of installations, such
as cable formations, cable sizes, insulation voltages and tray widths. The calculation applies to
the cables routed on the segment as part of the routing. Note that the Fill factor values can only
be between 0 and 1, as defined by the NEC code. The software takes into account the fill factor
that you specify and the maximum weight per length unit allowed on tray. If any of the actual fill
values exceed the allowed values, the software rejects them from being routed and displays a
warning message on the Cableway Segment Common Properties box.
The tray fill calculation flowchart is available in the SmartPlant Electrical installation folder in
the following path:
Program Files\SmartPlant\Electrical\Program\resdlls\0009\TrayFillCalcsFlowchart_SPEL.pdf
The Flexible tray type check box is not available When NEC validation is set to Yes.
171
Cable Routing
to save.
172
SECTION 12
Cable Drums
SmartPlant Electrical provides for the management of cable drums. You can create cable drums
and assign one or more cables to a cable drum. The cable drum assignment feature helps you
plan cabling tasks and optimize cable drum use. It also allows you to determine cable lengths so
that you can purchase cables while minimizing a shortage or surplus of cable at the end of the
project.
Before you begin, make sure that you have defined cable pulling areas in the Data
Dictionary Manager. For more information, see Data Dictionary Manager Online Help.
You can assign cables to drums manually or automatically.
Manual Assignment
When assigning cables to drums manually, you associate a drum with a specific reference cable.
You can define multiple drum sizes for each reference cable. These drum sizes are based on
various cable lengths that a drum can hold. Once you associate a drum with a reference cable that
has multiple drum sizes, you can select the most appropriate drum size for a particular drum. For
details, see Create a Cable Drum (on page 174).
Automatic Assignment
When assigning project cables to drums automatically, the software optimizes the cable
assignment. SmartPlant Electrical optimizes this assignment based on the drum sizes, the
maximum percentage of free cable length on the drums and the scrap cable length that you have
defined for each reference cable that you select for drum assignment. For more details, see
Optimization of Cable Drum Assignment.
You perform automatic cable assignment by using the Assign Drums to Cables wizard. When
using the wizard, you define the assignment parameters by selecting the following:
All the available reference cables or just one specific reference cable.
One or more pulling area.
The wizard will then assign all the project cables that comply with these parameters. Furthermore,
the software will optimize cable assignment to the drums based on the drum sizes, the maximum
percentage of free cable lengths on the drums, and the scrap cable length that you have defined
for each reference cable that you selected in the wizard. For details, see Batch Assign Cables to
Cable Drums (on page 177).
Although the order may vary, the following activities are essential elements in cable drum
assignment for a given pulling area:
Create reference cables and define sets of cable lengths so that you can optimize cable
assignment to drums.
Create project cables based on the reference cables.
Create cable drums for all of the reference cables used in the pulling area.
Assign all of the project cables in the pulling area to cable drums.
For detailed information about the logic used by SmartPlant Electrical to optimize cable drum
assignment, see Optimization of Cable Drum Assignment.
173
Cable Drums
The sets of cable lengths that are available on the Drum Sizes dialog box are taken from
the Design Data tab of the reference cable that has been set for the current drum. The
Minimum and Maximum values pertain to the Minimum cable length to order and
Maximum drum capacity values that are on the Cable Drum Common Properties
dialog box.
You can add new Minimum and Maximum values and change the existing Minimum
and Maximum values even after assigning plant cables to a drum.
Note that the drums that have the procurement status set to Ordered or Delivered are not
affected by the change that you make.
When changing the Minimum and Maximum values, the software validates that the new
values that you enter are within the range of the cable length definitions according to the
following:
If the Total cable length to order/delivered has been set, the Minimum cable
length to order cannot be greater than the Total cable length to order/delivered
value.
If the Total cable length to order/delivered has not been set, the Minimum cable
length to order can be greater than the Total cable length on the drum value.
9. Enter values for the other cable drum properties. For details, see Cable Drum Common
Properties Dialog Box (on page 639).
For calculation details, see Rules Governing Cable Drum Calculations (on page 181).
174
Cable Drums
You cannot change the drum reference cable when cables are assigned to the drum.
You cannot delete a drum if a cable has been assigned to that drum.
For calculation details, see Rules Governing Cable Drum Calculations (on page 181).
175
Cable Drums
5. Select an appropriate set of cable lengths and click OK.
The sets of cable lengths that are available on the Drum Sizes dialog box are taken from
the Design Data tab of the reference cable that has been set for the current drum. The
Minimum and Maximum values pertain to the Minimum cable length to order and
Maximum drum capacity values that are on the Cable Drum Common Properties
dialog box.
You can add new Minimum and Maximum values and change the existing Minimum
and Maximum values even after assigning plant cables to a drum.
Note that the drums that have the procurement status set to Ordered or Delivered are not
affected by the change that you make.
When changing the Minimum and Maximum values, the software validates that the new
values that you enter are within the range of the cable length definitions according to the
following:
If the Total cable length to order/delivered has been set, the Minimum cable
length to order cannot be greater than the Total cable length to order/delivered
value.
If the Total cable length to order/delivered has not been set, the Minimum cable
length to order can be greater than the Total cable length on the drum value.
6. Define at least one pulling area by doing one of the following:
a. To set a single pulling area, select a value from the Pulling area list.
When clicking Add in the Assigned cables group box, the software will look only for
those cables that are associated with the pulling area that you select from this list.
Make sure that the Allow multiple pulling areas check box is not selected.
a. To set multiple pulling area, select the Allow multiple pulling areas check box.
When clicking Add in the Assigned cables group box, this option instructs the software
to look for all the cables that are associated with the current reference cable.
7. Click Add in the Assigned cables data window.
8. On the Find dialog box, click Find Now.
9. In the Results data window, select the cables that you want to assign to the current drum, and
click OK.
You can assign to a particular drum only those cables that are associated with a designated
reference cable and only those cables that belong to one or more pulling areas assigned to the
drum.
For calculation details, see Rules Governing Cable Drum Calculations (on page 181).
176
Cable Drums
4. On the Cable Common Properties dialog box, click the Design Data tab.
5. In the Drum Assignment group box, click Find.
The software finds only those cable drums that have been associated with the
same reference cable and pulling area as the current cable.
6. On the Find dialog box, click Find Now.
7. In the Results data window, select the cable drum to which you want to assign the cable, and
click OK.
If a cable exceeds the maximum cable drum capacity, the software automatically defines the
required cable splices for that cable. You can view the specified lengths of the cable cuts on
the Design Data tab of the Cable Common Properties dialog box. Click View in the Drum
assignment group box.
For calculation details, see Rules Governing Cable Drum Calculations (on page 181).
177
Cable Drums
7. On the Select Cables page, do one of the following:
For each available cable that you want to assign to a drum, select the Select check box
beside the cable tag.
To select all of the cables that are available for assignment, select the Select all check
box.
You can specify the order of the cables that have not been assigned yet and organize
these cables either in a descending or alternate order. You set the sorting method on the
General page in Options Manager. If you select the Descending method, the software
sorts the cables starting with the longest cable and then goes down to the shortest one. If
you select the Alternate method, the software starts with the longest cable, then with the
shortest, then with the second longest and then back to the shortest again, and so on.
8.
9.
10.
11.
You can click the icon at the top right of the page
to display the page in full-screen
mode. You must click the icon again to restore the page to normal view before you can
proceed to the next step.
You cannot select cables for which pulling area or cable length values are missing. To
update the cable data, highlight the cable and click Common Properties.
If you select any cables that have restricted access rights, the software does not assign
them to drums, and the names of those cables appear in the error log.
Click Next.
On the Drum - Cable Assignment Summary page, view the details of the cables you have
selected to assign to cable drums.
Click Next.
On the Completing the Assign Drums to Cables Wizard page, view summary data for the
cable - drum assignment and click Finish to close the wizard.
If a cable exceeds the maximum cable drum capacity, the software automatically defines
the required cable splices for that cable. The Assign Drums to Cables Wizard specifies the
lengths of the cable cuts on the Completing the Assign Drums to Cables Wizard page.
178
Cable Drums
Collecting the Cable Drum and Cable Data for Drum Assignment
During this stage, the software collects all the available drums and the cables for the assignment
process. The software considers all the existing drums in the current plant and the cables that you
select in the Assign Drums to Cables wizard.
Drums Included in the Optimization Process
The software checks all the available drums and looks for those drums that comply with the
following requirements:
All the drums that have been associated with the pulling areas that you select in the Assign
Drums to Cables wizard.
Drums for which the procurement status is set to Ordered or Delivered. If the procurement
status is not defined, the software uses the Maximum drum capacity values of such drums in
the optimization process.
Drums for which the Total cable length to order/delivered value is defined. If this value is
not defined, the software uses the Maximum drum capacity values of such drums in the
optimization process.
As SmartPlant Electrical collects the cable drum data, it lists all the suitable drums in a virtual list
which is sorted according to the total free space that is available on the drums, starting with those
drums that have the most available free space to the least available free space.
Cable drums that are defined as spare and cable drums that are associated with multiple
pulling areas are not included in the optimization process by SmartPlant Electrical.
Cables Included in the Optimization Process
SmartPlant Electrical includes the following cables in the optimization process:
All the cables that you select in the Assign Drums to Cables wizard and which have not yet
been assigned to any drums.
If you select the Include assigned cables option in the Assign Drums to Cables wizard, the
software includes all the cables that already have been assigned to cable drums and which
you select in the Assign Drums to Cables wizard.
Cables that have been defined as installed or locked, remain assigned to their
original drums and are not re-assigned to other drums during the optimization process.
As SmartPlant Electrical collects the cable data, it lists all cables in a virtual list which is sorted in
descending or alternate order. The optimization process is based on the sorting order that you
define in Options Manager.
179
Cable Drums
If a particular cable cannot be assigned to a drum at this stage, the software puts it aside and
this cable will be assigned at a later stage.
The software tries to reduce the maximum capacity of the existing drums that have not been
defined as ordered or delivered and those drums whose Total cable length to
order/delivered value is not defined.
At this stage no new drums are created yet. This will be done during the next stage if you
select the Create new drums option in the Assign Drums to Cables wizard.
If a cable is longer than the Maximum free length on drum value that was set for that drum,
the software tries to increase the maximum capacity of that drum according to the available
drum sizes defined for the associated reference cable.
If the software still cannot assign another cable to a drum even after increasing the maximum
capacity of the drum, that cable remains unassigned.
If a cable is longer than the drum maximum capacity and if you selected the Create new
drums option in the Assign Drums to Cables wizard, the software automatically creates the
cable cuts that are required for that cable. The software specifies the length of each cable cut
and assigns it to a different drum as needed. Note that these cable cuts are virtual cuts. The
entire cable will be shown in all the pertinent reports and cable schedules and not the
individual cable cuts.
180
Cable Drums
The software stops looking for the best cable composition for drums when:
A particular cable composition fills the drum to the optimum.
There are no more available drum sizes left in the Drum sizes list of the associated
reference cable.
The next available drum size is shorter than the longest cable in the current cable
composition.
If the Maximum free length on drum (%) value has not been defined for the associated
reference cable, the software tries to find the most suitable cable composition during every
cycle of the cable assignment.
At the end of the process, the software deletes the empty drums if you select the Delete
empty drums option in the Assign Drums to Cables wizard.
181
Cable Drums
182
SECTION 13
Associating Equipment
This section deals with the association of electrical equipment. There are several ways that you
can make electrical associations. The particular method that you choose depends on your
workflow and specific requirements.
In This Section
Electrical Engineer ......................................................................... 183
Create an Electrical Association .................................................... 186
Change an Existing Electrical Association .................................... 191
Dissociate an Item from Its Feeding Item ...................................... 193
Associate Electrical Equipment with Feeders................................ 194
Automatic Creation of Feeder Circuits ........................................... 195
Associate Bus Riser Circuits with Coupler Circuits ....................... 196
Associate a Control Station with an Electrical Item ....................... 196
Associate a Control Station with Cables ........................................ 197
Associate Cables of Control Stations with Equipment Circuits ..... 197
Associate Cables of Instruments with Equipment Circuits ............ 197
Associate a Power Cable with Electrical Equipment ..................... 198
Associate Additional Power Cables with Electrical Equipment ..... 198
Associate a Non-Power Cable with Electrical Equipment ............. 199
Define Parallel Equipment ............................................................. 200
Create a Daisy-Chain Connection Pattern .................................... 202
Move Disconnect Equipment into Circuit ....................................... 203
Move Disconnect Equipment out of Circuit .................................... 203
Electrical Engineer
You use the Electrical Engineer to create and manage electrical associations among equipment
in your plant. You can make new electrical associations or change the existing ones. You can
create electrical associations by dragging items from the Electrical Index to an appropriate place
in the electrical tree of the Electrical Engineer window. For the rules that govern electrical
associations, see Rules for Associating Electrical Equipment (on page 187).
To change an electrical association, drag an item in the Electrical Engineer to another place in
the electrical tree. For more details, see Change an Existing Electrical Association (on page 191)
and Rules for Changing Electrical Associations (on page 192).
The software synchronizes any new electrical relationships that you create in the Electrical
Engineer with the Electrical Index. When creating a new item in the Electrical Index, the
software also adds this item in the Electrical Engineer if appropriate (some items do not appear
the Electrical Engineer).
The Electrical Engineer allows you to generate and display single line diagrams
(SLDs) that show the electrical network distribution powered from an item selected in the
Electrical Engineer.
183
Associating Equipment
Display Rules
The Electrical Engineer displays electrical items based on their electrical
relationship. Therefore, a power source, for example, is always on a higher hierarchical level
than a load. The Electrical Engineer also shows every item that has an electrical connection with
a selected item. The following rules define which electrical items appear in the Electrical
Engineer:
The Electrical Engineer displays all electrical items that have at least one electrical
association.
Certain items appear automatically in the Electrical Engineer after you create them in the
Electrical Index. These items appear in the Electrical Engineer even if they do not have
any electrical association. These items are generators, buses, circuits, battery banks, battery
chargers, UPSs, and transformers.
The Electrical Engineer automatically displays power cables that the software creates when
you create a load or when you activate the Apply Option command to automatically associate
that load with a feeder.
For a multiple cable assembly, you can hide or display the individual cables by right- clicking
the icon
, and on the shortcut menu, clicking Show Multiple Cables. The software
indicates the display toggle state by a check mark.
Items that have no hierarchical parents appear at the root of the Electrical Engineer provided
that they feed other items.
For equipment items that are connected in parallel, the software uses a special indicator next
to the equipment items that are connected in parallel.
The indicator is
. For example
.
Certain items do not appear in the Electrical Engineer. These items are power distribution
boards, cells, control stations, and their cables. Only the items that are included in single line
diagrams or power distribution networks appear in the Electrical Engineer except for circuit
components that do not appear in the Electrical Engineer at all.
You can display item tags of buses, bus risers, and incomers together with the item tags of the
associated power distribution boards if you set your general preferences accordingly.
The Electrical Engineer window contains the following sections:
Toolbar
Tree view pane
These sections are described below:
Toolbar
The toolbar contains the following options:
Find Click Find
to open the Find dialog box where you can look for a specific item in the
Electrical Engineer. Click the arrow to display a menu with the following options:
Find Opens the Find dialog box where you can look for a specific item in the Electrical
Engineer.
Find in Electrical Index Searches the Electrical Index for the item that is currently
selected in the Electrical Engineer. Note that both the Electrical Engineer and the
Electrical Index have to be open if you want to use this feature.
Close Closes the active Electrical Engineer window.
Refresh Click Refresh
to update the Electrical Engineer display. This feature is useful
where multiple users are working on the same set of data.
184
Associating Equipment
Buttons Buttons provide a useful shortcut to an item or a group of items. Click Buttons
to toggle show / hide for existing buttons. To create a button for the currently selected item or
folder, click the arrow and click Add Button. To remove a button, select the button to remove,
then click the arrow, and click Remove Button. Note that if you do not select any button to
remove, the software removes the uppermost button in the list.
You can open several instances of the Electrical Engineer by clicking Window > New >
Electrical Engineer.
You can right-click any item in the Electrical Index to find it in the Electrical Engineer or click
an item in the Electrical Engineer to find it in the Electrical Index. Both the Electrical
Engineer and Electrical Index have to be open if you want to use this feature.
You can right-click any item in the Electrical Engineer and then click Expand All Sub-Items
on the shortcut menu to display all the existing child items of the selected items. After clicking
this option a second time, click Refresh to expand the items in the Electrical Engineer tree
view.
You can filter the display of the Electrical Engineer and show only the selected branches of
the network structure by clicking Show Only on the View menu.
To display all the existing data in the Electrical Engineer, close the Electrical Engineer and
open a new session by clicking
on the main toolbar.
Also, you can display the selected branches of the network structure in a new Electrical
Engineer window by clicking Show in New Window on the View menu.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
The software highlights the parent item in the Electrical Engineer. You can repeat the
procedure to find another parent item.
To select a single item and close the Find dialog box, click OK.
185
Associating Equipment
186
There are specific rules that govern electrical associations. These rules determine electrical
associations of items in the Electrical Engineer. For more information, see Rules for
Associating Electrical Equipment (on page 187).
You also can make electrical associations in a cable block diagram. For details, see Place and
Connect Items in a Cable Block Diagram (on page 324).
Associating Equipment
Target Item in
Result
Electrical Engineer
Cables
Generators
Cables
Battery banks
Cables
UPSs
Cables
Capacitors
Cables
Secondary
The source item
The source item has no
transformer windings becomes the child item parent item in the
of the target secondary Electrical Engineer.
transformer winding in
the Electrical
Engineer. The dragged
item inherits all the target
transformer relations.
Cables
Battery chargers
Preconditions
187
Associating Equipment
Source Item in
Electrical Index
Target Item in
Result
Electrical Engineer
Cables
Variable frequency
drives (VFDs)
Cables
Panel-circuits
Cables
Miscellaneous
electrical equipment
Motors, heaters,
Generators
resistors, capacitors,
harmonic filters,
battery banks, heat
traces, UPSs, primary
transformer windings,
battery chargers,
miscellaneous
electrical equipment,
other converting
equipment, disconnect
electrical equipment,
auxiliary contacts
188
Preconditions
Associating Equipment
Source Item in
Electrical Index
Target Item in
Result
Electrical Engineer
Preconditions
Motors, heaters,
resistors, harmonic
filters, heat trace,
UPSs, miscellaneous
electrical equipment,
disconnect electrical
equipment, auxiliary
contacts
Battery banks
Resistors, capacitors,
harmonic filters, heat
traces, UPSs, battery
charger, VFDs,
miscellaneous
electrical equipment,
disconnect electrical
equipment, auxiliary
contacts
Secondary
The source item
transformer windings becomes the child item
of the target secondary
transformer winding in
the Electrical
Engineer. The dragged
item inherits all the target
transformer relations.
Capacitors, harmonic
filters, battery banks,
disconnect electrical
equipment
Battery chargers
Motors, heaters,
UPSs
resistors, harmonic
filters, battery banks,
heat traces, variable
frequency drives
(VFDs), miscellaneous
electrical equipment,
disconnect electrical
equipment, auxiliary
contacts
Motors, heaters,
VFDs
capacitors, harmonic
filters, transformer
windings,
miscellaneous
electrical equipment,
other converting
equipment, disconnect
electrical equipment,
auxiliary contacts
189
Associating Equipment
Source Item in
Electrical Index
190
Target Item in
Result
Electrical Engineer
Preconditions
Motors, heaters,
Circuits
resistors, capacitors,
harmonic filters,
battery banks, heat
traces, UPS, primary
transformer windings,
battery chargers,
VFDs, cables, other
converting equipment,
disconnect electrical
equipment, auxiliary
contacts
Motors, heaters,
Cables
resistors, capacitors,
harmonic filters,
battery banks, battery
chargers, heat traces,
UPSs, primary
transformer windings,
VFDs, cables,
miscellaneous
electrical equipment,
other converting
equipment, disconnect
electrical equipment,
auxiliary contacts
Panel-circuits
Cables
Cables
Associating Equipment
Special Conditions
The software creates the following electrical items automatically in the Electrical Engineer when
you create them in the Electrical Index. These items appear at the root of the Electrical
Engineer tree view after you create them in the Electrical Index even if they do not have an
existing electrical relation.
Buses
Generators
Battery banks
UPSs
Battery chargers
Transformers
You can connect electrical items in a daisy-chain pattern. For more information, see Create a
Daisy-Chain Connection Pattern (on page 202).
You cannot dissociate the following items, that is, you cannot drag them to the root of the
Electrical Engineer:
Buses
Feeder circuits
Coupler circuits
Transformer secondary winding
191
Associating Equipment
The following notes apply to making electrical associations either in the Electrical
Engineer or cable block diagram.
Whenever you drag a load or any equipment item from one bus to another, the software
automatically creates a new feeder circuit. The old feeder circuit from which you dissociated
the dragged item remains in its original place. For more information, see Automatic Creation
of Feeder Circuits (on page 195).
If you choose to automatically create a feeder circuit with a cell, make sure that in the
Properties window for the new cell, you select the In Use setting for the Cell Usage property.
If you want to dissociate a load from a circuit and this is the last associated load, make sure
that in the Properties window for the appropriate cell, you select the Installed Spare setting
for the Cell Usage property.
For details on how to create a new electrical association, see Create an Electrical Association
(on page 186).
192
Target Item
Result
Coupler circuits
Panel - Circuits
Cables
Cables
Panel - Circuits
Associating Equipment
Source Item
Target Item
Result
Loads
Special Conditions
Changing the association of a terminated power cable by dragging it to another equipment item in
the Electrical Engineer, disconnects this cable from the terminal strip of that equipment. The
software disconnects the cable without displaying a warning message.
If the dragged item has no hierarchical parent item:
The system creates a new relation with the parent item.
The system copies all the existing associations from the target item to the dragged item. The
copied associations include the highest item in the hierarchy, such as a load or an incomer
circuit.
If the dragged item has a hierarchical parent item:
Dragging it to another item that is not its parent item dissociates the dragged item from its
current parent item.
The dragged item acquires a new electrical relation with the item to which it is dragged. The
copied associations include the highest item in the hierarchy, such as a load or an incomer
circuit.
The system copies all the existing associations from the target item to the dragged item. The
copied associations include the highest item in the hierarchy, such as a load or an incomer
circuit.
You can connect electrical items in a daisy-chain pattern. For more information, see Create a
Daisy-Chain Connection Pattern (on page 202).
The dissociated item moves to the root of the tree view of the Electrical Engineer provided
that it is associated with at least one other electrical item. If the dissociated item has no other
193
Associating Equipment
electrical associations, it disappears from the Electrical Engineer. Note that the software
also dissociates from the feeding item all the items that are associated with the dissociated
item.
When dissociating the last load from a circuit, select the Installed Spare setting for the Cell
Usage property.
The software can create undesired and unpredictable associations when you try to dissociate
a load that is connected to its feeder through more than one branch (for example, a cable or
junction box), or when you move one of the feeding branches to another electrical item. To
avoid unwanted associations, you must first dissociate the load. Only then can you dissociate
the remaining items in the multiple branches. If you do not dissociate the load first, the
software may leave undesired associations in the Electrical Engineer.
You can only associate equipment that is not already assigned to an existing circuit. To
verify whether an association exists, right- click the item and click Find in Electrical
Engineer.
You can also associate a load with a feeder by dragging the load to the appropriate feeder
circuit in the Electrical Engineer. For details of this procedure, see .Create an Electrical
Association (on page 186).
2. Right-click the selected electrical item and click Common Properties to open the appropriate
dialog box.
3. Click the Feeder Data tab.
4. In the Location group box, under Power distribution board, select a power distribution
board.
If you select a PDB without specifying a bus, on clicking Apply or OK, the software
creates the new electrical item without a circuit.
5. Under Bus, select a bus with which you want to associate the current electrical item.
If required, you can select a cell in the Cell list to filter the circuits located in that cell.
6. Do one of the following to associate the new item with a feeder circuit:
Under Circuit, select an existing circuit with which you want to associate the current
electrical item.
Select the Create circuit check box to automatically create a new feeder circuit based on
the last applied typical circuit. The software creates an empty circuit without any circuit
components if the current electrical item is not associated with a typical circuit. If you do
not select this check box, the software only associates the selected bus with the loads
without creating any circuits. Where a last applied typical circuit is indicated, the software
creates the new circuit based on the typical circuit. Also, you can select the Create cell
check box to automatically create a cell when the software creates the new feeder circuit.
194
Associating Equipment
If you select a cell without selecting an existing circuit, the software automatically
creates a new circuit when you click Apply or OK.
7. Continue defining the feeder data as required and click OK when done.
If you choose to automatically create a feeder circuit with a cell, make sure that in the
Properties window for the new cell, you select the In Use setting for the Cell Usage property.
After specifying a circuit, applying the change, and exiting the dialog box, you can no longer
change the feeder data values from the dialog box.
A circuit can feed more than one electrical item.
It is possible to connect a number of heat tracers and Miscellaneous Electrical Equipment
items in a daisy-chain pattern.
195
Associating Equipment
Also, you can use a cable to connect a bus riser with a coupler. To do this, in the Electrical
Engineer, drag the desired cable to a coupler. Then, drag a sectionizer to that cable. Note
that you can use only a single cable and not a series of cables for this purpose.
To facilitate the drag-and- drop operation and to eliminate the need to scroll up or down in the
Electrical Engineer, open another Electrical Engineer window and navigate to the desired
location in the tree view before you drag an item.
196
You can also associate a control station with an electrical item using the Apply Options
feature for the electrical item with which you want to associate a control station. If you apply a
control station to an item that is connected to a circuit, the software associates the control
station cables (instrumentation and control) with the circuit automatically when you select the
appropriate Options Manager setting. If you do not use this setting, you need to make the
association manually. For details, see Associate Control Station Cables with Equipment
Circuits (see "Associate Cables of Control Stations with Equipment Circuits" on page 197).
You can associate only one control station with an electrical item.
Associating Equipment
The Find dialog box displays only control and grounding cables that have at least one
unassociated side.
You can associate one control station with more than one cable.
You cannot associate a control station with a power cable.
197
Associating Equipment
If an item already appears in the Electrical Engineer, you can drag a cable onto the item
where this is allowed.
You can associate a power cable with a motor by defining a motor profile with that cable and
then applying the profile to the desired motor.
Changing the association of a terminated cable by dragging it to another equipment item in the
Electrical Engineer, disconnects this cable from the terminal strip of that equipment. The
software disconnects the cable without displaying a warning message.
198
Cables that you associate in this way do not appear in the parallel cable list in the Cable
Common Properties dialog box of other cables connected to the same load.
Associating Equipment
If you dissociate a cable from the feeder, the software automatically dissociates that cable
from the load and dissociates all the other parallel cables from the feeder; however, those
cables remain associated with the load.
Changing the association of a terminated cable by dragging it to another equipment item in the
Electrical Engineer, disconnects this cable from the terminal strip of that equipment. The
software disconnects the cable without displaying a warning message.
When defining naming conventions for parallel cables, you can determine where in the cable
tag name you want to include the parallel cable suffix. In Options Manager, on the Define
Naming Conventions dialog box (Options > Naming Conventions > Define), define the
parallel cable suffix in the Segment definitions section. You can move the parallel cable
suffix property up or down the list to set the position of this property in the segment definition.
If you do not select this check box, the suffix for the parallel cables will appear at the end of the
cable tag name.
Changing the association of a terminated cable with another equipment item on the Cable
Common Properties dialog box, disconnects this cable from the terminal strip of that
equipment. The software disconnects the cable without displaying a warning message.
199
Associating Equipment
The definition of a parallel relationship between items is subject to certain rules. For details,
see Rules Governing Parallel Relations (on page 201).
The software does not allow you to make parallel connections or change existing parallel
connections of cables on the Cable Common Properties dialog box. Parallel cable
connections or changes of parallel associations can be carried out only in cable block
diagrams.
1. Do one of the following:
Click Actions > Manage Parallel Equipment.
On the Actions toolbar, click
.
2. On the Parallel Equipment Assistant dialog box, under Show parallel equipment data,
select one of the following filtering options to determine what data you want to see in the
Parallel equipment definition grid:
Show all existing parallel pairs shows all the existing parallel equipment items that
have been defined as pairs in the current plant.
Parallel pairs placed on the current cable block diagram only shows only those
paired equipment items that have been placed on the current cable block diagram.
Parallel pairs not placed on any cable block diagram shows only those paired
equipment items that have not been placed on any cable block diagram.
3. In the Parallel equipment definition grid, click Add to append a new empty row.
4. Select the new row and then click
under Item 1 and Item 2 to find appropriate equipment
items.
5. Under Input/Output, click the list arrow and select In or Out to set the parallel connection on
the inlet or outlet side of the equipment.
The list arrow and
appear only after selecting a row.
To cancel a parallel definition, select a row and click Remove.
6. Do one of the following:
Click Apply if you want to define or change another pair of items.
Click OK to accept all your definitions and close the Parallel Equipment Assistant.
200
After completing the definition of the parallel pairs and opening a cable block diagram, all the
parallel pairs become available in the Parallel pairs list on the Modify Connector ribbon.
This ribbon becomes available after clicking a cable that has been placed on a cable block
diagram. For details, see Connect Equipment Items in Parallel (on page 202).
Associating Equipment
Example
Loads
Converting equipment
Transformers
only the IN side.
All other
converting
equipment types
can be
connected on
both sides.
Transformer
components
Another transformer
component only.
Generators
Generators only
Incomer circuits
Junction boxes
Both sides: IN to
IN and OUT to
OUT
Local panel
Both sides: IN to
IN and OUT to
OUT
Panel circuits
Both sides: IN to
IN and OUT to
OUT
You can use the following items between equipment items connected in parallel:
Cables.
Standalone disconnect electrical equipment.
201
Associating Equipment
For parallel connection, you can only select a cable that is not connected on either end.
Once you click a cable or a connector, the software opens the Modify Connector ribbon.
For details on the various commands that are available on this ribbon, see Modify
Connector Ribbon (on page 834).
3. On the Modify Connector ribbon, from the Parallel Pairs list, select the pair of items that you
want to connect in parallel. The software displays the connection points on all the symbols of
the pertinent equipment items.
The Parallel Pairs list contains the items that have been placed on the current cable
block diagram and that have been defined as parallel pairs in the Parallel Equipment
Assistant. For details, see Define Parallel Equipment (on page 200).
Some of the paired equipment items that appear on the Parallel Pairs list may appear
disabled. This means that at least one of the items belonging to this pair has already been
connected in parallel with another equipment item.
4. Drag an end of the selected cable to a connection point on an equipment item symbol.
202
On the Batch Load Association dialog box, the software displays items connected in a
daisy-chain pattern as if they are all connected in a parallel pattern. The software handles
both parallel and daisy-chain connections in the same way.
Associating Equipment
On the Common Properties dialog box, items connected in a daisy-chain pattern appear as if
they are fed from the same feeder circuit.
You cannot drag loads that are connected in a daisy-chain pattern to the same circuit to create
a parallel connection. However, you can drag them to other circuits.
203
Associating Equipment
204
SECTION 14
Load Association
This section deals with PDB/bus load associations and balancing load data.
3.
4.
5.
6.
7.
8.
9.
You can also associate a single load without selecting a batch of loads in the Item Tag
pane of the Electrical Index. This way you can associate different loads belonging to
any load category in the Electrical Index. For more details, see Associate a Single Load
with a PDB (on page 208).
Also, you can select the desired loads in the Tabular Editor.
Click Actions > Batch Load Association.
On the Batch Load Association dialog box, under Power distribution board, select the
desired power distribution board.
From the Bus list, select a bus with which you want to associate the loads.
On the Bus tab, specify the rated data for the selected bus as needed and click Apply.
Click the Loads tab.
Click Add Selected Loads to add the items to the Associated loads list. (You selected
these items in the list view pane of the Electrical Index.)
In the Associated loads box, scroll to the right and define the phase assignment of the
current load by selecting the appropriate Phase check boxes.
205
Load Association
10. Under Create circuits and cells, select the Create circuits check box to automatically
create a circuit for each associated load that has not been assigned to a circuit. Note that this
option does not affect the loads that have already been assigned to circuits.
If you do not select the check boxes under Create circuits and cells, the software
associates the selected loads with a power distribution board or a bus. You can create
circuits at a later time.
Note that circuits have a property called CircuitMode with values Connected and
Disconnected. If you set this property to Disconnected, the drill down algorithm will
stop the calculation there and will not roll up the loads connected to this feeder.
11. Select the Create cell check box to automatically create a cell where the new feeder circuit for
the associated load will be created.
Make sure that in the Properties window for the new cell, you select the In Use setting
for the Cell Usage property.
12. Click Add to add other loads to the association.
13. On the Find dialog box, in the Results data window, select the loads that you require.
For further details about selecting items, see the Find dialog box.
The software finds only those items that have the Is Load property in the Properties
window set to True or if this item is defined as a Consumer in the Common Properties
dialog box. Also, the Find dialog box displays only those load items that aren't
connected to a bus.
14. Under Electrical consumption using coincidence factors, select one of the following
calculation modes:
For direct loads only to calculate the total consumed power only for those loads that
are connected directly to the current bus.
For all feeders to calculate the total consumed power for all the loads fed by the
current bus as well as the loads that are fed by the buses that are connected to the current
bus (as specified in Options Manager). When you select this option, the Circuits tab
becomes available.
You can set a preference that instructs the software to take into account any existing
transformer power losses. For details, see Customize All Feeder Load Summary Report
Preferences (on page 31).
15. Click Re-Calculate to refresh the display of the calculated values.
When selecting a PDB that contains a large downstream electrical distribution system, it
may take some time for the software to perform all the calculations before it displays all the
values. To avoid this situation, when opening the Batch Load Association dialog box, the
software displays the values that were stored in the database during the last
calculation. Clicking the Re- Calculate button allows you to re-calculate and refresh the
display the current calculation values.
16. To associate loads that have been associated only with a PDB and not with a bus, click the
Unassigned Loads tab.
17. Under Unassigned loads, select the item tag type and the Select check box for each load
that you want to associate.
18. Click Assign to Bus.
The software moves the selected load to the Loads tab.
19. Click Apply.
206
Load Association
20. Click the Bus tab and define the bus rated data.
If, after calculating the rated power for all feeders, you move to the Bus tab and change
the bus data, make sure that you click Apply before you switch back to the Loads tab.
21. Click the Loads tab and set the load phases.
22. Continue adding loads as you require and then click OK when done.
For information about associating a load with a different bus, see Balance Bus Loads (on
page 212).
The following table summarizes the information presented on the Loads and
Circuits tabs of the Batch Load Association dialog box:
Item Type
Calculated Results
Loads connected
directly to the
selected bus.
Shown as
non-compensated values.
Converting
equipment
Converting
equipment losses
Cabinets and
instruments
Shown as
non-compensated values.
Not applicable
Coupler circuit
Not applicable
Circuits Tab
Electrical items are included in calculations if they are defined as consumers. In addition to
loads, you can define converting equipment items, cabinets, local panels, and junction boxes
as consumers. To define an electrical item as a consumer, you have to set the Is Load
property in the Properties window for that item to True or define the electrical item as a
Consumer in the relevant Common Properties dialog box.
If you define a converting equipment item, local panel, or junction box as a consumer and
perform a drill-down calculation, the software uses the rated and consumed electrical load
values of the equipment as the load values, the software ignores the entire branch that is
connected downstream from the equipment. Note that you enter the pertinent rated and
consumed electrical load values on the Common Properties dialog box of the equipment
item.
207
Load Association
You can assign a load to a particular phase only if you defined the properties of the current bus
as having an AC supply and you set a value for the number of phases.
The software displays the calculated consumption values according to the loads associated
with each bus for the selected phase. If you do not select any bus from the Bus list, the
software calculates the consumption for the entire power distribution board.
The software can take into account converting equipment power losses if you have set your
report preferences accordingly. For details, see Customize All Feeder Load Summary Report
Preferences (on page 31).
If you associate a capacitor, the software subtracts the consumed kVAr value of that capacitor
from the total connected consumed kVAr value. Therefore, the consumed electrical power
(kVAr) may display a negative value. This means that there is a lagging power factor.
When performing bus load association and assigning a load to another bus on the Cached
Loads tab of the Bus Load Association dialog box, the software checks if the selected load
is associated with a heater that is connected through an auxiliary contact that is fed from the
same circuit as the selected load. If the software detects such a heater, it will prompt you to
move the associated circuit together with the load. If you click Yes, the software will move the
load and its heater together with the associated circuit to another bus. If you click No, the
software will only move the selected load without moving the heater or the circuit. In this case,
you will have to move the associated heater manually.
If a particular load associated with a selected PDB or bus contains incomplete data, the
software displays an appropriate message in the Note box.
To cancel an association of an item, under Associated loads, select a row and click Remove.
You cannot dissociate a load if it is connected to a circuit.
4.
5.
6.
7.
You do not have to select a bus if you do not want to associate any loads with a specific
bus under the selected PDB. In this case, the software calculates the load consumption for
the entire power distribution board rather than for a specific bus.
Click the Loads tab.
Click Add to open the Find dialog box.
From the Equipment type list, select the desired equipment type.
Click Find Now.
The software finds only those load items that have the Is Load property in the
Properties window set to True or if this load is defined as a Consumer in the Common
Properties dialog box. In addition to loads, you can define other electrical items as
consumers. These items are converting equipment items, local panels, and junction boxes.
Also, the Find dialog box displays only those load items that are not connected to a bus.
8. From the data window, highlight the desired load item tag.
9. Click OK to associate the load with the selected PDB.
208
Load Association
10. Under Create circuits and cells, select the Create circuits check box to automatically
create a circuit for each associated load that has not been assigned to a circuit. Note that this
option does not affect the loads that have already been assigned to circuits.
If you do not select the check boxes under Create circuits and cells, the software
associates the selected loads with a power distribution board or a bus. You can create
circuits at a later time.
11. Select the Create cell check box to automatically create a cell where the software will create
the new feeder circuit for the associated load.
Make sure that in the Properties window for the new cell, you select the In Use setting
for the Cell Usage property.
12. Under Associated loads, scroll to the right and define the phase association of the current
load by selecting the appropriate Phase check boxes.
13.
14.
15.
16.
17.
18.
19.
The following table summarizes the information presented on the Loads and
Circuits tabs of the Batch Load Association dialog box:
Item Type
Calculated Results
Loads connected
directly to the
selected bus.
Shown as
non-compensated values.
Converting
equipment
Converting
equipment losses
Circuits Tab
209
Load Association
Item Type
Calculated Results
Cabinets and
instruments
Shown as
non-compensated values.
Not applicable
Coupler circuit
Not applicable
210
Circuits Tab
You can assign a load to a particular phase only if you defined the properties of the current bus
as having an AC supply and you set a value for the number of phases.
To cancel an association of an item, under Associated loads, select a row and click Remove.
You cannot dissociate a load if it is connected to a circuit.
The software displays the calculated consumption according to the loads associated with each
bus. If you do not select any bus from the Bus list, the software calculates the consumption
for the entire power distribution board.
When performing bus load association and assigning a load to another bus on the Cached
Loads tab of the Bus Load Association dialog box, the software checks if the selected load
is associated with a heater that is connected through an auxiliary contact that is fed from the
same circuit as the selected load. If the software detects such a heater, it will prompt you to
move the associated circuit together with the load. If you click Yes, the software will move the
load and its heater together with the associated circuit to another bus. If you click No, the
software will only move the selected load without moving the heater or the circuit. In this case,
you will have to move the associated heater manually.
If you associate a capacitor, the software subtracts the rated kVAr value of that capacitor from
the total connected rated kVAr value. Therefore, the rated electrical power (kVAr) may
display a negative value. This means that there is a lagging power factor.
If a particular load associated with a selected PDB or bus contains incomplete data, the
software displays an appropriate message in the Note box.
Load Association
The software displays the calculated electrical consumption for the selected bus.
To view the calculated electrical consumption for a particular phase, select the check boxes as
you require in the Bus phases group box.
Balancing Loads
Load balancing is an operation that you can perform at any stage of your project. However, it is
recommended that you perform load balancing before you create feeder cables between loads
and their circuits, and before you apply profiles to the loads. The reason for this is that when you
move loads between buses, associated power cables remain attached to the previous feeder
circuits.
211
Load Association
12. If desired, click Excel Report to view the results in an Excel file.
The software uses the total bus amperes as the basis for calculating the total bus load,
including any loads connected downstream. The input for the calculation comes from the
consumed active and reactive loads.
The software does not perform bus load validation for loads that have incomplete data, that is,
where any of the following properties has a value of zero:
The consumed active load.
The consumed reactive load.
The coincidence factor (X, Y, Z, or ZZ) that applies for the load.
Operating mode (governs the coincidence factor used in consumed electrical power
calculations.
Demand factor.
Power factor at Demand
Efficiency at Demand.
The software moves the load from Associated loads list to the Cached Loads tab.
Repeat the two previous steps for each load that you want to dissociate from the currently
selected bus.
Click the Cached Loads tab.
Click Apply.
From the Power distribution board and Bus lists, selected the desired PDB and bus to
which you want to move the cached loads.
On performing this step, the software prompts you to save the changes. If you click Yes,
the software dissociates the cached loads from the bus to which they were assigned, and
you can now reassign them.
Also, the software displays a message allowing you to move the selected bus together
with its feeding circuit and the circuit internal items. However, if the load that you want to
move is connected to the bus through converting equipment, the feeding circuit cannot be
moved with the load.
11. Do one of the following:
For each load that you want to reassign, select the check box in the Item Tag column.
To reassign all of the loads in the list, select the Select all check box.
212
Load Association
12. Click Assign to Bus.
When performing bus load association and assigning a load to another bus on
the Cached Loads tab of the Bus Load Association dialog box, the software checks if the
selected load is associated with a heater that is connected through an auxiliary contact that is
fed from the same circuit as the selected load. If the software detects such a heater, it will
prompt you to move the associated circuit together with the load. If you click Yes, the
software will move the load and its heater together with the associated circuit to another bus.
If you click No, the software will only move the selected load without moving the heater or the
circuit. In this case, you will have to move the associated heater manually.
13. If you have not assigned all the items to new buses, repeat the three previous steps for each
load that you want to reassign.
The Cached Loads tab behaves as a temporary data store only; the software removes all
loads from the list when you close the dialog box.
213
SECTION 15
The software takes into account any existing equipment that is connected in parallel.
When making calculations, SmartPlant Electrical considers the worst case scenario in its
calculation results and does not take into account any load flow that would be taken into
account by a power analysis application such as ETAP. That is, for calculation purposes,
SmartPlant Electrical always assumes that the total connected load is supplied from one
source only. If there are multiple sources that supply the same connected load, SmartPlant
Electrical assumes that each source has the capability to supply the connected load.
SmartPlant Electrical, unlike any power analysis application, does not account for multiple
sources that share a load. Consequently, in SmartPlant Electrical, the total load for a
distribution network can appear artificially high unless the Circuit Mode property is set to either
Connected or Disconnected as desired on specific circuits.
214
P
= P mechanical / ( efficiency at working point))
Prated = 100 kW/0.9 = 111.1kW
Pconsumed = 80 kW/0.884 = 90.5kW
Reactive power:
Q
= P * tan (arcos (cos ))
Qrated = 111.1 * tan (arcos 0.85) = 68.9 kVAR
215
216
Compensated values rated and consumed electrical load kW, kVAR, and kVA values
multiplied by coincidence factors. It is possible to instruct the software to use one of the
following coincidence factors as shown on the Reports tab of the Preferences dialog box:
Use each load coincidence factor coincidence factor values of individual loads
Use Bus PDB coincidence factor bus coincidence factor values
Example
Let's assume that an intermittent load has the following values:
Rated active power = 11.1 kW
Rated reactive power (calculated or entered manually) = 6.9 kVAR
Consumed active power = 8.5 kW
Consumed reactive power = 5.9 kVAR
Operating mode = intermittent
Y = 0.5 (intermittent coincidence factor)
The uncompensated values would be as follows:
Uncompensated rated active power = 11.1 kW
Uncompensated rated reactive power = 6.9 kVAR
Uncompensated consumed active power = 8.5 kW
Uncompensated consumed reactive power = 5.9 kVAR
The compensated power values would be as follows (uncompensated values multiplied by the
coincidence factor):
Compensated rated active power = 5.55 kW
Compensated rated reactive power = 3.45 kVAR
Compensated consumed active power = 4.25 kW
Compensated consumed reactive power = 2.95 kVAR
Bus and circuit totals depend on the settings of your preferences. Therefore, run the bus load
calculation to update the total values in the bus, circuit, and load properties.
Electrical items are included in calculations if they are defined as consumers. In addition to
loads, you can define converting equipment items, cabinets, local panels, and junction boxes
as consumers. To define an electrical item as a consumer, you have to set the Is Load
property in the Properties window for that item to True or define the electrical item as a
217
218
Circuit Mode
The calculation of bus load summary depends on the mode of the circuits. The circuit mode
property can be Connected or Disconnected and it controls whether the loads are connected or
disconnected to the bus. You set the circuit mode on the Circuit Common Properties dialog
box or in the Properties window. Setting the circuit mode to Connected means that power flows
through the circuit and it acts as a connecting line between the power source and the consumer
device. Setting the circuit mode to Disconnected interrupts the circuit connectivity and it means
the power is not flowing therefore, the downstream connected loads or buses are not taken into
account in the calculation.
The following situations can arise when identifying the buses that are connected to a particular
bus:
219
The software also takes into account loads that are connected in parallel and loads that are
connected in a daisy chain. For details, see Configuration H: Loads Connected in Parallel (see
"Configuration I: Multiple Loads Connected by a Junction Box" on page 241) and Configuration I:
Loads Connected in a Daisy-Chain Pattern (see "Configuration J: Loads Connected in a
Daisy-Chain Pattern" on page 243).
220
221
222
As shown above, the loads that connect the upper bus are the direct loads as well as all the
downstream connected buses which in turn also have loads that are connected to them
directly. Any calculation of the upper bus also takes into account the downstream connected
loads. Note that the software does not set any limitation on the number of downstream levels of
buses for a network. The software makes a recursive calculation.
223
Bus 400V, 500A, 3PH and bus 120V, 500A,3PH are coupled (connected) by the coupler and riser
circuits which in principle serve as mutual backups for power supply.
224
The software takes into account any existing equipment that is connected in parallel.
When making calculations, SmartPlant Electrical considers the worst case scenario in its
calculation results and does not take into account any load flow that would be taken into
account by a power analysis application such as ETAP. That is, for calculation purposes,
225
226
The bus grand total apparent power is calculated 2 = 8 times (for run and peak, compensated
and uncompensated, rated versus consumed power) as a vector sum of grand total of active and
reactive power:
(S) = ((P)) + (Q)) )
Where:
2
227
228
The following two images show the connection of Motor M-2 to Bus A through a feeder.
229
The calculation results remain the same in both cases, regardless of whether the
connection is direct or indirect.
230
231
232
See pages 10 and 11 of the Bus Load Configuration Examples.pdf., file for bus total calculation
configuration examples with and without the converting equipment losses.
233
234
235
236
SmartPlant Electrical makes it possible to calculate the total of bus loads for coupled buses in one
of three ways depending on your report preference setting:
Do not include coupled buses Includes in the calculation only those loads that are connected
to the current bus and does not include the loads that are connected on the redundant buses.
See the Bus Load Configuration Examples.pdf., page 17.
Include coupled buses connected by couplers only Includes in the calculation the loads
connected on the current bus as well as loads connected on all the redundant buses that are
connected to the current bus by a coupler circuit. See the Bus Load Configuration
Examples.pdf., page 18.
Include coupled buses connected by couplers and risers Includes in the calculation the
loads of the current bus as well as the loads on all the redundant buses that are connected to the
current bus by coupler and riser circuits. See the Bus Load Configuration Examples.pdf., page
19.
237
238
239
240
241
242
243
244
245
246
Where:
Qcb = Reactive Power of the Capacitor Banks to be connected to the bus in order to have the
desired cosd.
P = The active power drawn from the bus.
Q = The reactive power drawn from the bus before connecting the power factor compensating
capacitor.
1. On the Bus tab of the Batch Load Association dialog box, type a value under Required
power factor. This value determines the required power factor for the selected bus.
2. Click the Loads tab.
3. Under Electrical consumption using coincidence factors, select the For all feeders
option in order to make sure that the software performs a calculation that includes all
downstream loads and not only the ones that are connected directly. Also, the software will
recalculate the electrical consumption and the required corrective reactive power for the
selected bus.
4.
5.
6.
7.
8.
9.
10.
11.
If you choose to close the Batch Load Association dialog box at this time, you can also
run this calculation by clicking Actions > Calculate Bus Loads > Selected PDBs or Buses.
On the Batch Load Association dialog box, click the Loads tab.
Under Required capacitor correction [kVAR], copy the calculated value. You can copy
either total running load or the total peak load value as you require.
Click OK on the Batch Load Association dialog box.
In the Electrical Index, create a new capacitor bank. For details, see Create Static Electrical
Equipment (on page 85).
On the Common Properties dialog box for the new capacitor bank, click the Load Data tab.
Under Rated power, paste in the Required capacitor correction [kVAR] value that you
copied from the Batch Load Association dialog box.
Click the Feeder Data tab and associate the current capacitor bank with the bus for which you
ran the electrical consumption calculation.
Click OK to accept the values you entered and close the Common Properties dialog box.
You can now open the Batch Load Association dialog box and recalculate the bus load
consumption for that bus. Under Power factor@Run and Power factor@Peak, You can see
the newly calculated power factor values for the current bus associated with the new capacitor
bank while the value under Required capacitor correction value is zero or close to zero.
247
248
You can customize the Enhanced All Feeder Load Summary report according to your needs.
For details, see Customizing the Enhanced All Feeder Load Summary Report (on page 390).
You use the calculation results as a basis for equipment sizing.
249
Bus Properties
Calculated Line Currents @ Using Coincidence Factor Compensated Load Data
LineCurrent_Normal_Consumed
LineCurrent_Peak_Consumed
LineCurrent_Normal_Rated
LineCurrent_Peak_Rated
Calculated Total Rolled Up Bus Loading @ Using Consumed Load Data Compensated by
Coincidence Factors
ComplRolledupRunActiveLoad_Consumed
CompRolledupRunReactiveLoad_Consumed
CompRolledupRunApparentLoad_Consumed
CompRolledupRunPowerFactor_Consumed
CompRolledupPeakActiveLoad_Consumed
CompRolledupPeakReactiveLoad_Consumed
CompRolledupPeakApparentLoad_Consumed
CompRolledupPeakPowerFactor_Consumed
Calculated Total Rolled Up Bus Loading @ Using Rated Load Data Compensated by
Coincidence Factors
CompRolledupRunActiveLoad_Rated
CompRolledupRunReactiveLoad_Rated
CompRolledupRunApparentLoad_Rated
CompRolledupRunPowerFactor_Rated
CompRolledupPeakActiveLoad_Rated
CompRolledupPeakReactiveLoad_Rated
CompRolledupPeakApparentLoad_Rated
CompRolledupPeakPowerFactor_Rated
Calculated Total Rolled Up Bus Loading @ Using Consumed Load Data Without
Compensation of Coincidence Factors
250
UncompRolledupRunActiveLoad_Consumed
UncompRolledupRunReactiveLoad_Consumed
UncompRolledupRunApparentLoad_Consumed
UncompRolledupRunPowerFactor_Consumed
UncompRolledupPeakActiveLoad_Consumed
UncompRolledupPeakReactiveLoad_Consumed
UncompRolledupPeakApparentLoad_Consumed
UncompRolledupPeakPowerFactor_Consumed
UncompRolledupRunActiveLoad_Rated
UncompRolledupRunReactiveLoad_Rated
UncompRolledupRunApparentLoad_Rated
UncompRolledupRunPowerFactor_Rated
UncompRolledupPeakActiveLoad_Rated
UncompRolledupPeakReactiveLoad_Rated
UncompRolledupPeakApparentLoad_Rated
UncompRolledupPeakPowerFactor_Rated
Calculated Total Rolled Up Bus Loading per Operating Modes @ Using Consumed Load
Data with Compensation of Coincidence Factors
CompRolledupContinuousActiveLoad_Consumed
CompRolledupContinuousReactiveLoad_Consumed
CompdRolledupIntermittentActiveLoad_Consumed
CompRolledupIntermittentReactiveLoad_Consumed
CompRolledupStandbyActiveLoad_Consumed
CompRolledupStandbyReactiveLoad_Consumed
CompRolledupSpareActiveLoad_Consumed
CompRolledupSpareReactiveLoad_Consumed
Calculated Total Rolled Up Bus Loading per Operating Modes @ Using Rated Load Data
with Compensation of Coincidence Factors
CompRolledupContinuousActiveLoad_Rated
CompRolledupContinuousReactiveLoad_rated
CompdRolledupIntermittentActiveLoad_Rated
CompRolledupIntermittentReactiveLoad_Rated
CompRolledupStandbyActiveLoad_Rated
CompRolledupStandbyReactiveLoad_Rated
CompRolledupSpareActiveLoad_Rated
CompRolledupSpareReactiveLoad_Rated
Calculated Total Rolled Up Bus Loading per Operating Modes @ Using Consumed Load
Data Without Compensation of Coincidence Factors
UncompRolledupContinuousActiveLoad_Consumed
UncompRolledupContinuousReactiveLoad_Consumed
UncompRolledupIntermittentActiveLoad_Consumed
UncompRolledupIntermittentReactiveLoad_Consumed
UncompRolledupStandbyActiveLoad_Consumed
UncompRolledupStandbyReactiveLoad_Consumed
UncompRolledupSpareActiveLoad_Consumed
UncompRolledupSpareReactiveLoad_Consumed
251
UncompRolledupContinuousActiveLoad_Rated
UncompRolledupContinuousReactiveLoad_Rated
UncompRolledupIntermittentActiveLoad_Rated
UncompRolledupIntermittentReactiveLoad_Rated
UncompRolledupStandbyActiveLoad_Rated
UncompRolledupStandbyReactiveLoad_Rated
UncompRolledupSpareActiveLoad_Rated
UncompRolledupSpareReactiveLoad_Rated
Circuit Properties
Calculated Total Rolled Up Circuit Loading per Operating Modes @ Using Consumed Load
Data Without Compensation of Coincidence Factors
UncompRolledupContinuousActiveLoad_Consumed
UncompRolledupContinuousReactiveLoad_Consumed
UncompRolledupIntermittentActiveLoad_Consumed
UncompRolledupIntermittentReactiveLoad_Consumed
UncompRolledupStandbyActiveLoad_Consumed
UncompRolledupStandbyReactiveLoad_Consumed
UncompRolledupSpareActiveLoad_Consumed
UncompRolledupSpareReactiveLoad_Consumed
Calculated Total Rolled Up Circuit Loading per Operating Modes @ Using Rated Load Data
Without Compensation of Coincidence Factors
UncompRolledupContinuousActiveLoad_Rated
UncompRolledupContinuousReactiveLoad_Rated
UncompRolledupIntermittentActiveLoad_Rated
UncompRolledupIntermittentReactiveLoad_Rated
UncompRolledupStandbyActiveLoad_Rated
UncompRolledupStandbyReactiveLoad_Rated
UncompRolledupSpareActiveLoad_Rated
UncompRolledupSpareReactiveLoad_Rated
252
ActiveLosses
ReactiveLosses
The software makes the calculation and stores the results in the database.
You can now generate an enhanced all feeder load summary for the selected PDBs or buses.
The software takes into account any existing equipment that is connected in parallel.
The software makes the calculation and stores the results in the database.
You can now generate an enhanced all feeder load summary for the plant PDBs or buses.
The software takes into account any existing equipment that is connected in parallel.
253
254
SECTION 16
Drawing Templates
Drawing templates are required for single line diagrams and schematics. A drawing template
specifies the page size and orientation of the drawing, and can include a border and title
block. Several standard drawing templates are delivered with the software. You usually create a
new drawing based on one of these existing templates. However, you can create new templates
or customize existing templates to meet your particular needs. This is accomplished inside
SmartPlant Electrical.
The default storage locations for single line diagram and schematic templates are specified in
Options Manager. If you create a new template, you store it on the server in order for it to be
available for drawing creation.
Also, the software comes with a set of files containing borders and title blocks that fit the delivered
drawing templates. If you create a new template, you may also need to create a new title block
that fits your template correctly and that contains the appropriate information. You can create title
blocks in Catalog Manager or in a suitable graphics application such as SmartSketch.
The software embeds symbols that you insert in the template. For this reason, if you
modify a border or title block symbol and you want the change to appear in all of your templates,
you must reinsert the symbol in each template individually.
5.
6.
7.
8.
9.
You must create the border or title block file in advance with suitable dimensions for the
template using Catalog Manager or a suitable graphics application such as SmartSketch.
The inserted symbol is embedded in the template. For this reason, if you modify a border
or title block symbol and you want the change to appear in all of your templates, you must
reinsert the symbol in each template individually.
On the Select Symbol File dialog box, navigate to the desired file and click Open to display it
in the drawing view.
To position the border on the template, do one of the following:
Press the ESCAPE key to lock the border on to the template in the correct position relative
to the origin.
Drag and drop the border in the position you require.
To add text to the template, click Edit > Insert > Text.
You can add other drawing objects in the appropriate file format or text if required by clicking
Edit > Insert > Symbol.
Click File > Save and type a name for the file in the desired location.
255
Drawing Templates
Drawing templates are saved in a special format that is recognized only in SmartPlant
Electrical. Files in the format have an .spe extension, and you can only create them in SmartPlant
Electrical.
6.
7.
8.
9.
10.
You must create the drawing object in advance using Catalog Manager or a suitable
graphics application such as SmartSketch.
On the Select Symbol File dialog box, navigate to the desired file and click Open to display it
in the drawing view.
Move the drawing object to the desired position on the template.
To add text to the template, click Edit > Insert > Text.
Add or delete other drawing objects and text as required.
Click File > Save As and choose a name and location for the file.
256
Macro
Notes
&Plant.name
&Area.name.
&Unit.name.
&Subsystem.name.
Drawing Templates
Notes
&Document.ItemTag
&Document.Description
Document description
&Document.LastRevision
&Document.DocumentCategory
&Document.DocumentType
&Document.ItemStatus
&Document.YYY
Notes
&Revision.RevisionNumber.x
Revision number
&Revision.RevisionDate.x
Revision date
&Revision.CreateBy.x
Created by
&Revision.CheckBy.x
Checked by
&Revision.RevisionDescription.x
Revision description
&Revision.ZZZ.x
257
Drawing Templates
Notes
&Sheet.Quantity
&Sheet.Number
&Sheet.Name
Sheet name
When generating a report, for the correct macros to be retrieved on the title block of your
drawing, your working environment must be the same as the drawing. For example, if the objects
on your drawing were created in a section of your plant named Unit 1, you must be working in the
Unit 1 environment when generating the report, otherwise the software cannot retrieve the correct
macros.
258
SECTION 17
Schematics
A schematic is a graphical representation of wiring and motor control systems. You create a
schematic by assembling it from typical blocks.
A block is a graphical representation of an electrical item. Blocks are parts of a complete
drawing. To create a block, start by creating an entire drawing in Catalog Manager or any CAD
application such as SmartSketch, AutoCAD, or MicroStation. Once the complete drawing is
ready, you select a part of the drawing and turn it into a block.
You can generate schematics for the following item types:
All loads
All converting equipment
All disconnect equipment
Circuits
Buses
Generators
Battery banks
Instruments
The software can generate a schematic by retrieving data for power related items from one block
or several blocks. If your generated schematic drawings contain the same information (that is,
the information repeats itself in identical sections of different schematic drawings), you should
consider creating a schematic block for the repeated parts so that this single block can be used by
several other schematic drawings. Note that you can create schematic drawings that include
several sheets. Multi-sheet schematics are mostly used when you need to display complex
electrical equipment for which a single sheet is not enough to show all the relevant wiring details of
the equipment.
After creating a block, you define the macros for that block. A macro is the smart text that you
attach to the block graphic. The software retrieves this smart text from the database and attaches
it to the block, thus making it part of the block file. You can create your macros in Catalog
Manager, SmartSketch, AutoCAD, or MicroStation.
Also, you must attach your blocks to templates. A template contains the definition for the desired
title block, border, and page size. You attach your blocks to templates in Catalog Manager,
SmartSketch, or any other CAD application.
Before generating a schematic drawing, you create a typical block and a typical schematic that
you will attach to a load for which you want to generate a schematic drawing. For a detailed
workflow for generating and using schematic drawings, see Recommended Workflow for
Generating Schematic Drawings (on page 260).
259
Schematics
260
Schematics
6. Generate a schematic for the selected electrical item.
Select an electrical item in the Electrical Index and generate the new schematic. For more
information, see Generate a Schematic (on page 273). For information about creating multi-item
schematics for more than one tag, see Generate a Multi-Item Schematic (on page 274).
As an alternative to steps 4, 5, and 6, you can select an electrical item in the Electrical Index
and open the Generate Schematic dialog box where you can select a typical schematic and
then generate the drawing. If the selected typical schematic contains more than one block of
the same item type for which you have not predefined a sequence, you can now associate
each point with its proper project item.
Sometimes the software generates a schematic block with a scaling incompatibility between
the schematic blocks and the template used to generate the schematic drawing. This scaling
incompatibility occurs if you have used AutoCAD or MicroStation to create your graphical
block files. To correct this problem, you have to set the units of measure (inches or
millimeters) for the generated schematic drawing. For more information, see Set Units of
Measure for Generated Schematic Drawings (on page 277).
Description
Moving items
Inserting annotations and redlining Add text labels, symbols, or watermarks to your schematic as
annotations. Add text, linked symbols, circles, rectangles,
and lines to your schematic as redlining. For more
information, see Managing Annotations and Redlining (see
"Annotations and Redlining" on page 349).
Renaming a document and
entering revisions
Saving a schematic as an external With an open schematic, on the File menu, click Save
As. For more information, see Save a Schematic as an
file
External Document (see "Save a Schematic as an External
File" on page 279).
Printing a schematic
261
Schematics
262
Schematics
Macro Syntax
The macro text has to contain the SmartPlant Electrical item name, the name of the desired item
property, and a sequence number, according to the syntax:
&[ItemType].[Property].[Sequence]
For example, if you want to specify a name of a motor, the text label has to be:
&Motor.ItemTag.1
If a particular block contains several items of the same item type (that is, several cables, control
stations, and so on), you have to use the sequence number to ensure item uniqueness. For more
details, see Sequencing Items in Block Macros (on page 265).
You can also add the Unit or Area name to an item by using the following syntax:
&[ItemType].Unit.Name or &[ItemType].Area.name
263
Schematics
Panel Macros
Use the following syntax to create macros for local panels or junction boxes that include circuits:
&Circuit.Panel.[Property].[Sequence]
Cable Macros
Use the following syntax to create macros for cables:
&Cable.[Property].[Sequence] for power cables
&ControlCable.[Property].[Sequence] for control cables
&GroundingCable.[Property].[Sequence] for grounding cables
&InstrumentationCable.[Property].[Sequence] for instrumentation cables
Loads
Load blocks can include all the items that appear connected between a particular load and its
feeder circuit in the Electrical Engineer hierarchy. Also, load blocks include load-related object
properties regardless of whether these objects appear in the Electrical Engineer or not:
Direct load properties.
Related power cable properties.
Related grounding cable properties.
Related control cable properties.
Related instrumentation cable properties.
Related feeder circuit properties.
Related circuit internal properties (disconnect equipment)
Related bus properties.
Related cell properties.
Related power distribution board properties.
Related control station properties.
Related I/O signal item properties.
Circuits
264
Schematics
Control Stations
Converting Equipment
The properties of all electrical items connected above the converting equipment item up to the
first feeding bus and then down up to the first incomer circuit or load.
Related I/O signal item properties.
The properties of all electrical items connected below the power source item up to the first
incomer circuit.
Related I/O signal item properties.
Now you can do one of the following:
Continue with the next step in the recommended workflow for generating a schematic drawing
and learn how to create typical schematic blocks (on page 51).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
265
Schematics
266
Schematics
267
Schematics
268
Schematics
269
Schematics
270
Schematics
271
Schematics
272
Schematics
Generate a Schematic
1. In the Electrical Index, expand the Electrical Equipment folder and select an item for which
you want to generate a schematic.
The software allows you to generate schematics for the following item types:
All loads
All converting equipment
All disconnect equipment
Circuits
Buses
Generators
Battery banks
Instruments (for single instruments only)
2. Do one of the following:
Click Actions > Generate Schematic.
Right-click the selected item and then click Generate Schematic.
Click
on the toolbar.
3. On the Generate Schematic dialog box, under Typical schematic, select an appropriate
typical schematic that you created in the Reference Data Explorer.
4. Under Drawing name, type a name for the new schematic.
Examine the block data in the data window. Make sure that the typical blocks are
defined correctly and their displacement from the page origin is set correctly.
5. Click the Macros tab. Examine the macros in the data window. Make sure that each macro
is associated with a correct item. To associate a macro with another item, select a macro in
the data window and then under Macro details, select another item from the Macro item
name list.
6. Click the Unresolved Items tab to check whether there are item tags for which there are no
corresponding items in the associated typical schematic.
7. Click OK to generate the schematic.
The software can only generate schematic drawings for items that have predefined typical
schematics.
273
Schematics
4. Under Drawing name, type a name for the new schematic.
Examine the block data in the data window. Make sure that the typical blocks are
defined correctly and their displacement from the page origin is set correctly.
5. Click the Macros tab. Examine the macros in the data window. Make sure that each macro
is associated with a correct item. To associate a macro with another item, select a macro in
the data window and then under Macro details, select another item from the Macro item
name list.
6. Click the Unresolved Items tab to check whether there are item tags for which there are no
corresponding items in the associated typical schematic.
7. Click OK to generate the schematic.
274
Ensure that the column widths, the number of columns, and the properties that the
macros represent match the corresponding characteristics of the headers.
Since at this stage, the macros are not associated with a specific item type, the syntax of
the macro needs to include an expression representing the block type to which the item
type refers, as follows:
[ItemType].[Property].[Sequence].[BlockType].[BlockSequence]
The logic of the macro syntax for single-item schematics also applies to the macro syntax
for multi-item schematics. The macro syntax of multi-item schematics is almost the same
as the macro syntax of single-item schematics. The only difference is that for multi-item
schematics there is no definition of blocks. Therefore, you have to include the block name
in the macro syntax of multi-item schematics. The software retrieves the data from the
block type even if the associated item differs from the one that is associated with a
particular schematic.
The software resolves the macros according to each item that has been associated with
the current schematic drawing on the Document Properties dialog box. Note that if the
item type is Bus, the associated items are only circuits.
Schematics
Macro examples:
Macro
Explanation
&Cable.ActualLength.1.Motor.1
&Cable.ActualLength.2.Motor.1
&ControlStation.ItemTag.1.ControlStati
on.1
&ControlStation.ItemTag.1.ControlStati
on.2
2. For each of the symbol files that you created, define a typical block using the following block
types:
Multi-Tag Header on Drawing Page for the pages without drawings
Multi-Tag Header for the page where the drawing is placed (needed depending on the
typical schematic definitions)
Multi-Tag Macros for the macros that will appear in the schematic drawing
3.
4.
5.
6.
7.
8.
9.
10.
If you want to include a drawing on the first page of a schematic, you have to
create a typical block with a drawing. You can choose any block type for the drawing.
In the Reference Data Explorer, create a typical schematic that includes all the typical blocks
that you defined in the previous steps.
On the Typical Schematic Common Properties dialog box, select a multi-tag block type and
click Multi-Tag Options.
On the Multi-Tag Schematic Options dialog box, select whether to include a list on the main
drawing sheet, and specify the numbers of rows of data to appear on the main and
subsequent drawing sheets.
Apply this typical schematic to the tags that you want to appear in the multi-item schematic.
The tags must belong to the same subclass, for example, motors, heaters, or
transformers, and so forth.
In the Electrical Index, expand the Documents folder, and right-click the Schematic
Drawings folder.
Click New Multi-Tag Schematic.
Right-click the newly-created schematic, and on the shortcut menu, click Document
Properties.
On the Document Properties dialog box, from the Multi-tag typical schematic list, select
the typical schematic that you created in step 3.
275
Schematics
11.
12.
13.
14.
From the Multi-tag typical schematic list, select an appropriate multi-tag typical schematic.
Click the Associated Items tab.
Select an appropriate item type.
If you selected Bus from the Item type list, select an appropriate power distribution board and
bus.
15. If you did not select Bus from the Item type list, click the Associate button.
16. On the Find dialog box, click Find Now to find all the items belonging to the selected item type
that are associated with the current typical schematic.
17. In the Results box, select the items that you require and click OK.
All the items that you selected in the Results box appear in the Associated Items list.
You can dissociate the items that you don't need.
If you selected Bus from the Item type list, the Associated Items list automatically
displays all the circuits belonging to the current bus. You can sort these circuits either
according to their item tags or sequence in group values. The software updates this list
automatically if circuits have been added or deleted.
For more information about multi-item schematics for buses, see Generate a Multi-Item
Schematic for a Bus (on page 276).
18. Click OK.
19. In the Electrical Index, do one of the following to generate the schematic:
Double-click the schematic document.
Right-click the schematic, and on the shortcut menu, click Open.
Right-click any of the associated items, and on the shortcut menu, click Generate
Schematic. Ensure that in the dialog box that opens, under Drawing name, you select
the appropriate multi-item drawing.
When saving a multi-tag schematic as an external file, you need to save each page of the
schematic as a separate drawing.
276
Schematics
8. In the Electrical Index, expand the Schematic Drawings folder and select an appropriate
multi-tag schematic.
9.
10.
11.
12.
13.
Alternatively, you can click New Multi-Tag Schematic to create a new one.
Right-click the selected schematic drawing and then click Document Properties.
From the Multi-tag typical schematic list, select an appropriate multi-tag typical schematic.
Click the Associated Items tab.
From the Item type list, select Bus.
Select an appropriate power distribution board and bus.
The Associated Items list shows all the circuits belonging to the current bus. You can
sort these circuits either according to their item tags or sequence in group values.
The software updates this list automatically if circuits have been added or deleted.
14. Click OK.
15. In the Electrical Index, double-click the schematic document to open it.
The table in the schematic document displays all the circuits that belong to the current bus and
are sorted according to the setting you made on the Document Properties dialog box.
For information about macros that are used for this type of schematic, see Generate a
Multi-Item Schematic (on page 274).
277
Schematics
The software displays the schematic on the initial drawing sheets and Enhanced SmartLoop
reports on subsequent drawing sheets, with one or more sheets per loop.
The software supports multi- sheet Enhanced SmartLoop reports.
278
Schematics
5. Under Path, type the exact path where the files will be saved, or click the ellipsis button
to browse to the desired folder.
You can accept the displayed default path which you set in Options Manager.
6. From the Save as type list, select a file format.
7. Select the Print drawings check box if want to print out the generated schematics.
8. Click OK to generate the schematics.
The software can only generate schematic drawings for items that have pre- defined typical
schematics.
With the schematic drawing open, click File > Save As.
On the Save As dialog box, navigate to the desired folder.
Type the file name and select the desired file type.
Click OK.
Use the Grid Display and Grid Snap commands to place the origin properly.
Edit the origin properties and set the origin layer as hidden objects.
6. Draw your block. Make sure that you make the Default layer as the active layer.
279
Schematics
7. Add the SmartText.
If the SmartText requires repositioning, change the active layer to Label.
Do not forget to change the layer back to Default when you return to the drawing.
8. Add the macro text to retrieve the attributes that are not available for SmartText. For more
information about macro text, see Macro Definition Guidelines (on page 262).
9. Save the graphic as a symbol (.sym) file.
10. If the new symbol file is a complete typical schematic drawing, use it to create individual
schematic blocks. For more information, see Use a Complete Symbol File to Create
Schematic Blocks in Catalog Manager (on page 280).
280
Schematics
6. If the .igr file is a complete typical schematic drawing, use it to create individual schematic
blocks by doing the following:
a. Select a set of graphics and macros that will comprise the new block symbol.
b. Click the Create Symbol icon.
Make sure that the new symbol does not include any SmartSketch group (a
collection of objects). If your symbol does include a group, you must ungroup these
objects.
c. Move the symbol origin to the bottom left corner of the drawing sheet.
d. Save the new drawing as a symbol file in your default symbol folder.
When saving a drawing in AutoCAD format, you must specify the AutoCAD version prior to
saving. To set the AutoCAD version, open a drawing and then click Tools > Options. On
the Options dialog box, click the Foreign Data tab and select AutoCAD from the Format
list. Then, click Options in the Export box. On the AutoCAD Export Options dialog box,
select the appropriate AutoCAD version.
When importing graphical blocks that were created in AutoCAD for typical schematics, the
software automatically translates and identifies the AutoCAD file if its AutoCAD version is
supported by the software. The supported versions of AutoCAD appear on the Version list of
the AutoCAD Export Options dialog box.
Now you can do one of the following:
Continue with the next step in the recommended workflow for generating a schematic drawing
and learn how to create typical schematic blocks (on page 51).
Return to the Recommended Workflow for Generating Schematic Drawings (on page 260).
281
Schematics
282
SECTION 18
Displayed in SLD
Power sources
Shown
Buses
Circuit internals
Feeder circuits
Converting
equipment
Shown
283
Item
Displayed in SLD
Loads
Not shown apart from motors and heaters that have a minimum
rated power setting defined on the Miscellaneous tab.
Cables and
busways
Based on bus rated voltage Generates an SLD based on the bus rated voltage that you
select from the list below.
Electrical analysis SLD Generates a single line diagram that you can publish to an
electrical analysis application such as ETAP. Also, after selecting this option you have to
define the options for circuits and circuit internals on the Circuits and Internals tab.
284
Description
Moving items
Drawing frames
Moving frames
285
Description
Select a bus and then click the appropriate icon on the SLD
toolbar to change the line type, line width, or line color for the
selected bus. Note that the software retains new line display
settings only if you save the SLD as an external
document. Otherwise, after reopening the SLD, the software
displays the original bus symbol. You can use Options
Manager to change the symbol that the software uses to
represent busses. To create a new symbol for busses, use
Catalog Manager. For more information, see Guidelines for
Creating SLD Symbols in Catalog Manager (on page 310).
In the Catalog Manager, make sure that the bus symbol has a
dot that represents a connection point. After defining the
width and color of this dot, the software will use these
definitions in your SLDs.
Inserting annotations and redlining Add text labels, symbols, or watermarks to your SLD as
annotations. Add text, linked symbols, circles, rectangles,
and lines to your SLD as redlining. For more information,
see Managing Annotations and Redlining (see "Annotations
and Redlining" on page 349).
286
With an open SLD, on the File menu, click Save As. For
more information, see Save a Single Line Diagram as an
External File (on page 295).
Description
Printing an SLD
The software uses the following conventions to display parallel cables in an SLD:
[...] in the item tag label and (xN) in the cable configuration label, where N is the number of
cables, for example:
Cable-32/A[...]
3 x 150mm2 (x5)
This means that there are five parallel cables represented by the same line in the SLD.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
287
288
If you want to regenerate an open SLD drawing using different generation options, with the
SLD open, click Tools > Drawing Options.
To save the drawing as an internal document, in the generated SLD drawing, click File >
Save.
If there are overlapping connectors on the generated drawing, open the SLD and then click
Tools > Optimize Overlapping Connectors to reposition the connectors so that they do not
overlap. Note that this operation may take a few moments if your SLD contains a lot of
connectors.
For information on how to use custom symbols in your SLDs and the SLD legends, see Use
Custom Symbols in SLDs (on page 305).
If, during the SLD generation, the software cannot find a referenced symbol for a specific
electrical item, the software uses the default symbol file (default.sym) to represent the
item. You specify default files in Options Manager.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
To save the drawing as an internal document, in the generated SLD drawing, click File >
Save.
If there are overlapping connectors on the generated drawing, open the SLD and then click
Tools > Optimize Overlapping Connectors to reposition the connectors so that they do not
overlap. Note that this operation may take a few moments if your SLD contains a lot of
connectors.
For information on how to use custom symbols in your SLDs and the SLD legends, see Use
Custom Symbols in SLDs (on page 305).
If, during the SLD generation, the software cannot find a referenced symbol for a specific
electrical item, the software uses the default symbol file (default.sym) to represent the
item. You specify default files in Options Manager.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
289
290
If you want to regenerate an open SLD drawing using different generation options, with the
SLD open, click Tools > Drawing Options.
In order to save an annotation that was added to a manual SLD, make sure that first you click
Generate on the Drawing Options dialog box and only then save the drawing. This way, the
software saves the SLD together with the inserted annotation.
291
4.
5.
6.
7.
Click
on the toolbar.
Right-click the PDB, and then on the shortcut menu, click Generate SLD.
On the Single Line Diagram Options dialog box, select the Circuits and Internals tab, and
do the following:
Select the options you require.
Set the distance between the circuit internals and the circuits, remembering to make the
spacing wide enough so that the circuit items will not be crowded onto each other, and
require moving manually.
Select the Buses tab and select the required options.
Select the required options from the other tabs.
Click Generate.
For you to see the Bus Tie and its internal circuit you must use the correct symbols. The
Coupler circuit symbol, CircuitBusTieCoupler.sym and the Riser circuit symbol,
CircuitBusTieRiser.sym. Any of the symbols used in the internal circuits must use the syntax
<itemtype>BusTie.sym, for example CircuitbreakerBusTie.sym.
292
293
You can right-click an item and click Open SLD on the shortcut menu.
If the electrical item you selected is an origin for more than one SLD drawing, the software
opens the Open Single Line Diagram dialog box where you select the drawing that you want
to open.
If you have opened an SLD drawing whose electrical data has changed (for example, you
added or deleted a bus, moved a circuit, and so on), the software does not display the SLD
clearly and some of the items might overlap. To fix the SLD, with the SLD drawing open, click
Tools > Drawing Options. Set the required SLD options and click Generate. The
regenerated SLD drawing retains the existing annotations. However, it does not keep the old
circuit and circuit component placements in the drawing.
You can right-click an item and click Open SLD on the shortcut menu.
If you have opened an SLD drawing for a PDB whose electrical data has changed (for
example, you added or deleted a bus, moved a circuit, and so on), the software does not
display the SLD clearly and some of the items might overlap. To fix the SLD, with the SLD
drawing open, click Tools > Drawing Options. Set the desired SLD options and click
Generate. The regenerated SLD drawing retains the existing annotations. However, it does
not keep the old circuit and circuit component placements in the drawing.
294
You can right-click an SLD and click Open on the shortcut menu.
If you have opened an SLD drawing for which the electrical data has changed (for example,
where you added or deleted a bus, moved a circuit, and so on), the software does not display
the SLD clearly and some of the items might overlap. To fix the SLD, with the SLD drawing
open, click Tools > Drawing Options. Set the required SLD options and click
Generate. The regenerated SLD drawing retains the existing annotations. However, it does
not keep the old circuit and circuit component placements in the drawing.
295
If you are using customized symbols for cables and disconnect equipment, make sure that you
have prepared two symbols for these item types: one for the regular (vertical) display (for
example, MY_CABLE.SYM) and one for the horizontal display (for example,
MY_CABLE_PRL.SYM). You can, however, use the shipped symbols as you require.
The software displays parallel connectivity even if there are no cables between the parallel
equipment items.
Placement of Items
The general rule for placing electrical items in an SLD is determined by the power flow of the
electrical items in a given SLD. For the items in a parallel branch, the placement rule is determined
according to the sequence of items in the Parallel Equipment Assistant. For example, if in the
Parallel Equipment Assistant, you defined Motor_1 in the Item 1 column and Motor_2 in the
Item 2 column, the software will place Motor_1 to the left of Motor_2. However, if there is an
overlap in the placement of items on the drawing due to the parallel connection definitions, the
power flow rule overrides the rule determined by the Parallel Equipment Assistant. The
software will first place the items based the power flow and then arrange the items in the parallel
branches in accordance with the definitions made in the Parallel Equipment Assistant.
For manual SLDs, after placing an item that has been included in a parallel chain in
the Parallel Equipment Assistant, the software also automatically places all the items that have
parallel connection associations with the item you just placed.
These rules are illustrated in the following examples.
Example A:
Two variable speed drives connected in parallel.
In the Parallel Equipment Assistant:
296
Item 1
Item 2
V-1G-2
V-1G-3
In Electrical Engineer:
In a generated SLD:
Example B:
Two motors with a maintenance switch connected in parallel.
In the Parallel Equipment Assistant:
Item 1
Item 2
M1A
M1B
In Electrical Engineer:
297
In a generated SLD:
Example C:
Two transformers connected in parallel.
In the Parallel Equipment Assistant:
298
Item 1
Item 2
T-1A
T-1B
In Electrical Engineer:
In a generated SLD:
Example D:
Three motors connected in parallel. The SLD is based on a single power source.
In the Parallel Equipment Assistant:
Item 1
Item 2
MTR-1A
MTR-1B
MTR-1B
MTR-1C
299
In a generated SLD:
Example E:
Three motors connected in parallel. The SLD is based on two power sources.
In the Parallel Equipment Assistant:
300
Item 1
Item 2
MTR-1A
MTR-1B
MTR-1B
MTR-1C
In a generated SLD:
To define the display settings, such as the vertical and horizontal distance between the
equipment items, see Set Parallel (see "Set Parallel Equipment Display Options" on page 301)
301
302
Note that bus risers and couplers are always displayed on the same page adjacent to
each other.
To ensure that all the circuits are placed correctly, all the circuits must have sequence in
group values. The software places the circuits that do not have sequence in group values
first and only then the rest of the circuits.
4. Continue setting your options for the SLD generation as you require.
The software hides the bus feeders only for those buses whose Hide bus feeders property
has been set to TRUE. The other buses are displayed with all their feeders.
303
If a particular bus belongs to a PDB whose sub-items have been hidden, this bus and its
feeders will not be displayed in a single line diagram.
The software highlights the item it finds in the SLD. You can now click
to modify the
magnification level of the selected item. To cancel the selection, click somewhere outside the
drawing.
In redlining mode, the Find in SLD option is not available.
304
Once an SLD contains a legend, it behaves like any other element in the SLD. Therefore, you
can resize it or drag it to another place in the SLD.
The SLD legend contains the symbols that represent the electrical items in the open single line
diagram. Also, the software shows custom symbols if you have defined the Electrical
Equipment Type property and selected a symbol from the Symbol Name list in the
Properties window for a particular electrical item.
For information on how to use custom symbols in your SLDs and the SLD legends, see Use
Custom Symbols in SLDs (on page 305).
Click
.
Right-click the selected item and then click Associate Custom Symbols on the shortcut
menu.
3. On the Associate Custom Symbols dialog box, under Document Type click on a cell, and
from the list select Single Line Diagrams.
4. Under Symbol, click
.
5. Browse to the symbol (.sym) file you want to add, and select the file.
You can only choose symbols that are stored in the default folder and its
sub-folders.
6. Click OK.
If, during the SLD generation, the software cannot find a referenced symbol for a specific
electrical item, the software uses the default symbol file (default.sym) to represent the
item. You specify default files in Options Manager.
For guidelines about the creation of custom symbols in Catalog Manager, see Guidelines for
Creating SLD Symbols in Catalog Manager (on page 310).
305
306
Click
.
Click Edit > Remove.
Right-click, and from the shortcut menu, click Remove.
307
308
The assembly item properties now appear in the Properties window in SmartPlant Electrical.
In an assembly, items of the same type are sequenced in-group. It is possible to change the
sequence but two items cannot have identical sequence values.
It is possible to combine several assemblies into one.
Gapping Lines
A gap in a drawing is a condition that exists when two lines intersect graphically in the drawing but
not physically in the plant. In order to portray this condition, you can choose that lines show a gap
at these non-physical intersections. This can help the clarity of your drawing considerably.
Gapping is carried out automatically when you open an existing drawing. If you want to perform
gapping on a drawing that is already open, you must use the command Tools > Gap Now.
309
General Guidelines
When generating a single line diagram, SmartPlant Electrical searches for the symbols that match
the item type names. Therefore, all the symbol names must match the item type names of the
electrical items that you want to include in the SLD. You can, however, save a symbol file under
a different name and assign it to an electrical item using the Associate Custom Symbols
command from the Actions menu. In this case, the software will use the associated symbol file to
represent the electrical item in an SLD.
You have to set an item type for each symbol that you create. Each symbol consists of graphical
elements (lines, circles, and so forth), SmartText properties, fixed text (labels), connect points,
and an origin point.
Note that you can use all the graphical tools provided in Catalog Manager to create your symbols.
Connect Points
Two types of connect points are used in SLDs:
Connect Point for main power connection.
Auxiliary Point for creating the logical connection between equipment, metering, and
relays.
All symbols must have at least two connect points, apart from some exceptions listed below.
Each connect point consists of a:
Connection type Connect point or auxiliary point.
Connection angle The angle at which the connection is made between the equipment and
the connector.
Side A numeric value used to distinguish between the "power in" 1, and the "power out"
2, sides of the equipment.
Number A sequential, unique, index number for the connect point. Each side, within a
connection type, starts at number one and progresses in sequential steps.
The upper and lower connect points must have the same X coordinates.
310
Origin Point
Place the origin point in the middle of the existing or virtual line that connects the upper and lower
point.
Special Symbols
The software uses several symbols to represent a transformer in a single line diagram Transformer symbol and TransformerComponent symbols. You create each symbol
separately. However, the origin point of all the symbols has to be placed in such a way that when
the software superimpositions all the symbols, it creates a complete representation of a
compound transformer.
Use the following properties to create transformer symbols:
Symbol name Transformer
One upper connect point
Connection angle: 90 degrees (up)
Index 1
Symbol name TransformerComponent0
One lower connect point
Connection angle: 90 degrees (down)
Index 1
Symbol name TransformerComponent1
One lower connect point
Connection angle: 90 degrees (down)
Index 1
Symbol name TransformerComponent2
One lower connect point
Connection angle: -90 degrees (down)
Index 1
Catalog Manager uses the TransformerComponent0 symbol together with the Transformer
symbol to create a 2-winding transformer representation.
Catalog Manager uses TransformerComponent1 together with the Transformer and
TransformerComponent 2 symbols to create a 3-winding transformer representation.
You can customize the transformer and transformer component symbols in the SmartPlant
Options Manager. For more details, see Define a Transformer Component Symbol.
For an example of origin placement in each of the transformer symbols, you can open any of the
above mentioned symbol files located in the folder that you define in the Default SLD Symbol Path
location in Options Manager.
Bus symbols:
Bus SmartPlant Electrical creates bus representations in SLD
automatically. However, you still need to create a bus symbol and set its line type, line
width, and define SmartText attributes. The origin point must always be at the left edge
of the symbol.
SmartPlant Electrical uses the above properties to create the bus symbols in single line
diagrams. You can create as many bus symbols with different properties as required so
that you can generate single line diagrams with various line types and widths. Note that
SmartPlant Electrical uses only the symbol properties and not the file itself to represent
buses in single line diagrams. After creating bus symbols and defining their properties in
311
312
Catalog Manager, you can modify the bus properties prior to generating an SLD by
associating a different symbol file using the Associate Custom Symbols command from
the Actions menu. This way, the software can generate a single line diagram with
various bus representations.
Symbols that represent the connection between two buses in a PDB:
Horizontal representation Special symbols are used to show the horizontal connection
between two buses and their internals. The two symbols are CircuitBusTieCoupler.sym
and CircuitBusTieRiser.sym. All disconnect equipment, cable, or any other item that
needs to be displayed in the internals of the bus tie have a specific syntax,
<ItemType>BusTie.sym. The software generates the SLD and searches for the
BusTie.sym suffixed symbols if in the Single Line Diagram Options dialog box the circuit
internals have been chosen to be displayed. Note that the BusTie symbol is a circuit'
type symbol and has its first connection point on the rightmost side and the second
connection point at the leftmost side.
Vertical representation The standard bus coupler-riser circuit connection
representation that includes both coupler and the riser circuits and displays them as
vertical objects, connected to each other. The software displays both circuits as standard
arrows.
If you want to have more than one symbol to represent a bus tie, you can create a
custom symbol (for example, MyDisconnectSwitch.sym) and assign it, for example, to a
disconnect switch using a default symbol or custom symbol. Then, create another custom
symbol with the same name plus BusTie (for example, MyDisconnectSwitchBusTie.sym
and arranged horizontally if needed). Place this custom symbol in the SLD symbols folder.
SmartPlant Electrical will use this symbol if you select the Use bus tie symbols check
box on the Circuits & Internals tab of the Single Line Diagram Options dialog box.
Other symbols:
Other special symbols include <ItemType>Alt.sym used to represent equipment that has
two sources of power supply, Buswrappingmarker_Right, Buswrappingmarker_Left,
and Triangle- Compare .
Note that the connect point numbering sequence for an Alt.sym symbol is "main power
in" 1, "power out" 2, and "alternate power in" 3.
From This is a system symbol; do not modify it.
Default (Symbol name = Default) SmartPlant Electrical uses a default symbol
whenever a required symbol for a particular item type does not exist. Default symbols
require two connect points. You can select any item type for the Default symbol.
For information on how to use custom symbols in your SLDs and the SLD legends, see Use
Custom Symbols in SLDs (on page 305).
For information on how to place connect points in a symbol in Catalog Manager, see Place
Symbol Connect Points (on page 313) in the Catalog Manager User's Guide, under Working
with Symbols, Creating Symbols, Place Point Command.
A list of all shipped symbols and their SmartText attributes is available in the symbols.txt file
located in the folder that you define in the Default SLD Symbol Path location in Options
Manager.
SmartPlant Electrical shipped data includes two sets of transformer symbol files. The IEC set
includes:
TransformerIEC
TransformerComponent0IEC
TransformerComponent1IEC
TransformerComponent2IEC
The NEC set includes:
TransformerNEC
TransformerComponent0NEC
TransformerComponent1NEC
TransformerComponent2NEC
Since the software uses the Transformer, TransformerComponent0,
TransformerComponent1, and TransformerComponent2 symbols by default, you have to
replace this set with the NEC or IEC symbols and rename them without their IEC or NEC
suffixes if you want to use symbols belonging to another standard.
The following limitations of SLD symbol creation exist in Catalog Manager:
On the Smart Text Editor dialog box, you cannot use the Visible, Short Text, and
Format features.
The angles for the symbol connect points are fixed at 90 degrees for the top connect point
and -90 degrees for the bottom connect point.
There is no support of symbol properties in the Properties window except for the
selection of item types.
The software does not retain the assigned smart text labels if you change the item type of
a symbol for which smart text labels have been created.
In order for the software to rescale all the items correctly, make sure that when
creating symbols that contain text or smart text, the Units space property is set to World. Note
the World is not the default setting for this property.
You can also type the exact angle value in the Connect angle field to define the connection
angle.
You can right-click during this procedure to reset the command.
313
The mirror handle allows you to mirror about the horizontal and vertical axes, defined in
relation to the origin of the item. You can mirror items by dragging the mirror handle in the
appropriate direction. The software shows you the result of the operation dynamically so that
you can be sure to mirror the item correctly.
The rotate handle provides a mechanism for rotating components around their origin. You
can rotate items by dragging the rotate handle in the appropriate direction. The software
shows you the result of the operation dynamically so that you can be sure to rotate the item
correctly.
For more information, see Working with Labels in the SmartPlant Engineering Manager Users
Guide.
314
Align Center About Vertical Align labels so that their center points agree on a
horizontal line
Align Center About Horizontal Align labels so that their center points agree on a
vertical line
315
SECTION 19
317
For more information, see Working with Smart Data and Auxiliary Graphics in a CBD (on
page 320).
318
After saving the new CBD, the software associates the new plant items with the new CBD
drawing and allows you to open the new drawing from the Associated Drawings dialog box
(on page 620).
For more information about working with CBDs, see Working with Smart Data and Auxiliary
Graphics in a CBD (on page 320).
Click
.
Right-click and on the shortcut menu, click Open.
For information about placing items on a drawing and connecting cable between equipment
items in a CBD, see Place and Connect Items in a Cable Block Diagram (on page 324).
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
319
Description
320
Moving items
Placing cables
Description
321
Description
Placing connectors
322
Description
Inserting annotations and redlining Add text labels, symbols, or watermarks to your CBD as
annotations. Add text, linked symbols, circles, rectangles,
and lines to your CBD as redlining. For more information,
see Managing Annotations and Redlining (see "Annotations
and Redlining" on page 349).
Removing items from a CBD
Printing a CBD
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
Cable block diagrams do not allow you to make dual power source connections. You can
make these connections in the Electrical Engineer. After making such a connection in the
Electrical Engineer, the cable block diagrams generated for these items will display the dual
power source connections correctly. You can, however, disconnect an item from an alternative
power source in a cable block diagram.
323
You can drag the following items to an open cable block diagram:
All electrical equipment items apart from buses, and relay functions.
You can drag disconnect electrical equipment items if they are stand-alone items, that
is, if they do not belong to any circuits.
Metering equipment items can be dragged only if they are current transformers or
potential transformers.
All wiring equipment items (panels, cables, and so forth) apart from busways, glands and
cableway components.
In addition to smart graphics, you can also add auxiliary graphics, redlining, and
annotations to your CBD. For details, see Working with Smart Data and Auxiliary
Graphics in a CBD (on page 320). Once you save the drawing, the software retains all
your additions and modifications.
When placing a circuit or a PDB on a cable block diagram, the following rules apply:
Placing a circuit is allowed only if the parent PDB of the circuit is not in the current cable
block diagram.
Placing a power distribution board is allowed only if none of the child circuits have been
placed in the current cable block diagram.
3. To connect a cable that has been placed on a CBD drawing, do the following
a. In the open drawing, click an appropriate cable.
After clicking the cable that want to connect, the software switches on all the available
connection points on the equipment symbols that can be connected The software
displays only the connection points available for the specific category of the cable
chosen. For more details, see Place Point Ribbon (SmartPlant Electrical) in the
Catalog Manager User's Guide, under Working with Symbols > Place Point
Command. If no connection points are available, the software does not allow the
cable to be connected.
If the symbol to which you want to connect the cable does not have enough
connection points, the software displays a message informing you that there is a
shortage of connection points on that symbol.
b. Drag an appropriate cable end to the connection point of the item you want the cable to
connect 'From'.
324
For the rules that govern the connection to circuit symbols, see Rules for Connecting
to Circuit Symbols (on page 328).
When using a reference cable to connect items in a CBD, the software automatically
creates a plant cable in the Electrical Index and makes all the required associations.
4. To disconnect a cable from an electrical item in a CBD, click the required cable end and drag
it away from the connection point.
5. When done, click
You can also place auxiliary graphics, such as redlining, annotations, and water marks. For
information on how the software behaves when placing these and other items in a cable block
diagram, see Working with Smart Data and Auxiliary Graphics in a CBD (on page 320).
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
You can also associate cables with a specific circuit either in the Cable Common Properties
or the Electrical Engineer.
Clicking Refresh also saves the drawing. If you do not use Refresh or you make changes to
your drawing after refreshing, the software prompts you to save the drawing on closing.
You can move and reposition any item or cable by selecting and dragging the item to its new
position.
If you delete any of the items that have been placed on a drawing, this item will no longer
appear on the drawings.
You can drag disconnect electrical equipment items if they are stand-alone items, that is,
if they do not belong to any circuits.
Metering equipment items can be dragged only if they are current transformers or
potential transformers.
All wiring equipment items (panels, cables, and busways) apart from glands and cableway
components.
325
For a free-standing bus, you do not need to specify a power distribution board.
You can select the Create cell check box if you want to create the new circuit in a cell that
doesn't exist yet.
4. Click OK.
If your preferences are set to open the Item Tag dialog box after creating a new item, the
software opens this dialog box after you define the location of the new circuit and after placing the
symbol on the drawing. On the Item Tag, you can change the name of the new circuit as you
need.
326
If you insert text with an auxiliary graphic, the software displays this text in the same color that
you defined for the auxiliary graphic.
When you re-open a saved CBD, the software does not mark the auxiliary graphics
automatically. Click
to display the markings. To cancel the marking of auxiliary graphics,
click
again.
Click
.
Right-click the selected item and then click Associate Custom Symbols on the shortcut
menu.
3. On the Associate Custom Symbols dialog box, under Document Type click on a cell, and
from the list select Cable Block Diagrams.
4. Under Symbol, click
.
5. Browse to the symbol (.sym) file you want to add, and select the file.
You can only choose the symbols that are stored in the default folder and its
sub-folders.
6. Click OK.
If, during the CBD creation, the software cannot find a referenced symbol for a specific
electrical item, the software uses the default symbol file (default.sym) to represent the
item. You specify default files in Options Manager.
For guidelines about the creation of custom symbols in Catalog Manager, see Guidelines for
Creating SLD Symbols in Catalog Manager (on page 310).
327
328
If the software does not resolve all of the symbols, a message appears that instructs you to
open the log file where you can see which symbols have not been replaced.
The Resolve command button on the Resolve Symbol Inconsistencies dialog box is
available only after selecting at least one item tag to be resolved.
If a symbol cannot be resolved, the software indicates it under Expected Result. You can
click the Symbol cannot be resolved text to see the reason why the symbol cannot be
resolved.
You can change the filter at any time by going to the Document Properties dialog box and
selecting or clearing the relevant check boxes.
You can instruct the software to display the filter settings notation in your cable block
diagrams. For details, see Display Filter Settings Notation in a CBD (see "Display a Filter
Settings Notation in a CBD" on page 330).
If you want the software to display the name of the focal item in the title block of the associated
CBD, add a new macro to your document template, for example
&Document.Equipment.ItemTag.
To dissociate a focal item from the current CBD, click Clear next to the Focal item box.
329
1. In Catalog Manager or SmartSketch, open the appropriate title block symbol that is used in
your cable block diagram template.
The software supplies a number of shipped templates with title blocks (.sym files) in the
reference data.
2. In the open title block symbol, add the following macro text:
Document.Filters
You can insert the macro anywhere in the template depending on where you want the
notation to appear in your CBDs.
3. Save the modified template and close Catalog Manager.
4. In SmartPlant Electrical, click File > Open > Template and open the template that you
modified in Catalog Manager.
5.
6.
7.
8.
330
If the template contains a title block, select it and then delete it.
Click Edit > Insert > Symbol.
Select the .sym file to which you added the Document.Filters macro.
Click an appropriate X point in the template to insert the title block symbol.
Save and close the template.
All the cable block diagrams based on the modified template will display the filter settings
notation.
If you open a CBD that is not filtered, the software will not display the notation.
For details on how to set a filter for a CBD, see Hide Cable Types (on page 329).
SECTION 20
4.
5.
6.
7.
SmartPlant Electrical opens the Common Properties dialog box automatically after
creating a new item if you selected the Common Properties dialog box option on the
General tab of the Preferences dialog box.
On the Terminal Strip Properties dialog box, under Item tag, type a new name as you
require.
Type a short description if you require.
In the Terminal strip configuration group box, do one of the following:
Click Find to find an existing reference configuration that you can apply to the current
terminal strip. For details, see Apply a Reference Terminal Strip Configuration to a
Terminal Strip (on page 333).
Define a new terminal strip configuration. For details, see Define a Terminal Strip
Configuration for a Single Terminal Strip (on page 333).
Click OK.
331
4.
5.
6.
7.
8.
9.
10.
11.
SmartPlant Electrical opens the Common Properties dialog box automatically after
creating a new item if you selected the Common Properties dialog box option on the
General tab of the Preferences dialog box.
On the General tab of the Terminal Common Properties dialog box, under Item tag, type a
name for the new terminal as you require.
Type a short description if you require.
Select a terminal type that you require. You can define and customize types in Data
Dictionary Manager.
Select a terminal color that you require. You can define and customize terminal colors in
Data Dictionary Manager.
Under Sequence, type a value that sets the sequential number of the current terminal on its
terminal strip.
Click the Procurement tab.
Select a manufacturer and a model as you require. You can define and customize these
entries in Data Dictionary Manager.
Type a store part number if you require.
332
The software does not allow you to apply a reference terminal strip configuration to a terminal
strip that has already been wired.
If you apply a reference terminal strip configuration to a terminal strip that already has a
terminal strip configuration, the replaces the existing configuration with the reference
configuration that you are applying.
333
334
When you change the association of a terminated power cable by dragging it to another
equipment item in the Electrical Engineer, the software disconnects this cable from the
terminal strip of that equipment. Changing the association of a terminated non-power cable
on the Cable Common Properties dialog box also results in disconnection. The software
disconnects the cable without displaying a warning message.
The software allows you to wire non-power cables to all the circuits that belong to a PDB that
has already been associated with a non-power cable in a CBD or the Cable Common
Properties dialog box. In a wiring diagram, after placing the circuits of a PDB that has already
been associated with a non-power cable, the software identifies the connection points of these
circuits and enables you to wire the associated non-power cable or its constituents.
When designing electrical terminations of space heaters, to terminate the auxiliary contact
with a space heater or any other electrical equipment item, terminate the cable conductors to
the terminal strip of the circuit where the auxiliary contact is located.
In a wiring diagram, the software allows you to split the wires of a non-power cable and
terminate them to any terminal strip of any of the circuits of a PDB or of local panel or junction
box.
You can lengthen the connectors that represent conductors and cable sets in a wiring
diagram. To control the position of a conductor or cable set on a drawing, click the connector
that represents the conductor or cable set and then drag the connection point to the required
position on the drawing.
The Conductor field signifies a specific conductor in a cable set. The displayed Wire00x
values represent the conductor names and are used to illustrate the current connection
type configuration. This field is not editable.
The number of rows that you add has to match the number of conductors that will be
connected. The software does not connect the leftover conductors that do not have
connection type definitions in the Conductors data window.
9. Click OK.
335
You can drag any appropriate item such as a motor, circuit, panel, and so forth.
You can drag your items from the Electrical Index, Electrical Engineer, or Related
Items window.
4. Do one of the following:
Click Activate Connection Mode
.
Click Edit > Activate Connection Mode.
5. In the Electrical Index, Electrical Engineer, or Related Items window, select an appropriate
cable that you want to terminate.
You can connect only those cables that are associated with equipment on one or both
cable sides.
6. In the wiring drawing, move the cursor over the terminal strip that you want to connect to the
cable.
The software displays the available, valid connection points of the terminal strip on your
drawing. For more details, see Place Point Ribbon (SPEL) in the Catalog Manager User's
Guide, under Working with Symbols > Place Point Command.
7. Click the connection point of the terminal to which you want to connect the first conductor on
the appropriate side.
You can connect the first conductor to any terminal on the current terminal strip. The
software will then connect the remaining conductors according to the custom connection
type that you select. (See the following steps in this procedure.)
The number of conductors that you can connect cannot exceed the number of available
wiring connection points on a terminal.
You can connect only one conductor on a wiring connection point.
8. On the shortcut menu, click Custom Connection.
9. On the Cable Connection Type Selection dialog box, select a connection type you require.
10. Click Connect.
336
The software provides a set of default symbols for terminal strips, terminals, first terminals,
cables, cable sets, and conductors. You can customize your own wiring symbols in Catalog
Manager. For details, see Creating Symbols in the Catalog Manager User's Guide, under
Working with Symbols, Creating Symbols.
You can perform various actions in a wiring drawing, such as moving items by dragging them
to position the items in the drawing, removing items from the drawing, disconnecting cables,
and so forth.
Removing a wiring item from a drawing does not delete that item from your project.
Disconnecting two wiring items in a drawing, disconnects the items in your project, removes
the connecting cable from the drawing, and retains the association between the cable and the
items in your project. For details, see Disconnect Cables from Items in Cable Block
Diagrams.
Clicking Refresh saves the drawing. If you do not click Refresh or you make changes to your
drawing after refreshing, the software prompts you to save the drawing on closing.
To exit the Connection Mode select another command or press the ESCAPE key.
You can add other wiring items to the drawing by dragging them to drawing from the Electrical
Index or Related Items window.
After adding a wiring item that is connected to a cable, the drawing displays the item
connected to the cable on one of the cables sides and the name of the item tag of the wiring
item that is connected on the other cable side. After dragging that wiring item to the drawing,
software replaces the item tag name with the symbol of that wiring item.
The software allows you to add annotations and use redlining in your wiring drawings. For
details, see Managing Annotations and Redlining (see "Annotations and Redlining" on page
349).
If you move a macro to another place in the drawing, clicking a macro highlights the cable,
cable set, or conductor that is associated with that macro. This way you can see which cable,
cable set, or conductor belongs to that macro.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
You can drag any appropriate item such as a motor, circuit, panel, and so forth.
You can drag your items from the Electrical Index, Electrical Engineer, or Related
Items window.
337
You can connect the first conductor to any terminal on the current terminal strip. The
software will then automatically connect the remaining conductors in a sequential order.
The number of conductors that you can connect cannot exceed the number of available
wiring connection points on a terminal.
You can connect only one conductor on a wiring connection point.
8. On the shortcut menu, click Continuous Connection.
9. In the wiring drawing, move the cursor over the connection points of the second terminal strip.
10. On the shortcut menu, click Continuous Connection.
338
The software provides a set of default symbols for terminal strips, terminals, first terminals,
cables, cable sets, and conductors. You can customize your own wiring symbols in Catalog
Manager. For details, see Working with Symbols > Creating Symbols in the Catalog Manager
User's Guide.
You can perform various actions in a wiring drawing, such as moving items by dragging them
to position the items in the drawing, removing items from the drawing, disconnecting cables,
and so forth.
Removing a wiring item from a drawing does not delete that item from your project.
Disconnecting two wiring items in a drawing, disconnects the items in your project, removes
the connecting cable from the drawing, and retains the association between the cable and the
items in your project. For details, see Disconnect Cables from Items in Cable Block
Diagrams.
Clicking Refresh saves the drawing. If you do not click Refresh or you make changes to your
drawing after refreshing, the software prompts you to save the drawing on closing.
To exit the Connection Mode select another command or press the ESCAPE key.
You can add other wiring items to the drawing by dragging them to drawing from the Electrical
Index or Related Items window.
After adding a wiring item that is connected to a cable, the drawing displays the item
connected to the cable on one of the cables sides and the name of the item tag of the wiring
item that is connected on the other cable side. After dragging that wiring item to the drawing,
software replaces the item tag name with the symbol of that wiring item.
The software allows you to add annotations and use redlining in your wiring drawings. For
details, see Managing Annotations and Redlining (see "Annotations and Redlining" on page
349).
If you move a macro to another place in the drawing, clicking a macro highlights the cable,
cable set, or conductor that is associated with that macro. This way you can see which cable,
cable set, or conductor belongs to that macro.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
3.
4.
5.
6.
7.
8.
You can only connect cables in batch mode if they belong to the same category, for
example, power, control, instrumentation, and so forth.
Click Actions > Cables > Batch Cable Connection.
On the Batch Cable Connection dialog box, select the Activate cable side 1 (From) check
box, Activate cable side 2 (To) check box, or both check boxes.
Under Terminal strip sequence, type the sequence of the appropriate terminal strip that is
associated with the equipment you want to connect. The value you type defines the terminal
strip to be connected. Type a value for one or both cable sides as you require.
Under First terminal, type a value to instruct the software which terminal on the current
terminal strip is to be connected first.
Select an appropriate active connection side for one or both cable ends.
From the Connection type list for one or both cable sides, select an appropriate connection
type.
From the Connection type list, you can select Continuous (wire the first selected
terminal of an item and then automatically wire the rest of the terminals) or a name of an
existing custom connection type. If the connection type that you require is not on the list,
create it in the Reference Data Explorer. For details, see Define a Connection Type (on
page 335).
9. In the Cable connection details data window, select the Select check box next to the
appropriate cables that you want to connect.
10. Click OK.
When designing electrical terminations of space heaters, to terminate the auxiliary contact
with a space heater or any other electrical equipment item, terminate the cable conductors to the
terminal strip of the circuit where the auxiliary contact is located.
339
340
Connect a Jumper
This procedure shows you how to connect a jumper on a terminal strip.
1. In a wiring diagram that has a terminal strip, do one of the following:
Click Activate Jumper Mode
.
Click Edit > Activate Jumper Mode.
2. Select the first jumper connection point that you want to connect.
The software displays the available, valid jumper connection points on the terminal
strip. For more details, see Place Point Ribbon (SmartPlant Electrical) in the Catalog
Manager User's Guide, under Working with Symbols > Place Point Command.
3. Move the cursor to the next jumper connection point on the same terminal strip and click it.
Click
.
Click Edit > Disconnect.
Right-click, and on the shortcut menu, click Disconnect Items.
After you confirm the disconnection of a cable, the software disconnects the cable on both
sides and removes it from the drawing. However, the software does not delete the cable from
the project and retains the association between the wiring items and the cable.
When disconnecting cable sets or conductors, the software removes these items from the
drawing.
341
342
Click
.
Right-click and on the shortcut menu, click Open.
When opening a wiring drawing that contained a wiring item that has been deleted from your
project, the wiring drawing no longer displays this item, showing the cable and wiring item
connected to the other cable end.
If you deleted both wiring items that were connected to a cable, the wiring drawing displays the
cable only.
If you deleted a cable that was used to connect two wiring items, the wiring diagram shows the
two items as disconnected.
Removing a wiring item from a drawing does not delete that item from your project.
Disconnecting two wiring items in a drawing, disconnects the items in your project, removes
the connecting cable from the drawing, and retains the association between the cable and the
items in your project.
You can add other wiring items to the drawing by dragging them to drawing from the Electrical
Index or Related Items window.
After adding a wiring item that is connected to a cable, the drawing displays the item
connected to the cable on one of the cables sides and the name of the item tag of the wiring
item that is connected on the other cable side. After dragging that wiring item to the drawing,
software replaces the item tag name with the symbol of that wiring item.
The software allows you to add annotations and use redlining in your wiring drawings. For
details, see Managing Annotations and Redlining (see "Annotations and Redlining" on page
349).
If you move a macro to another place in the drawing, clicking a macro highlights the cable,
cable set, or conductor that is associated with that macro. This way you can see which cable,
cable set, or conductor belongs to that macro.
In a wiring drawing, the software does not show the item tag label for conductors whose
polarity property is defined as shield.
Sometimes, after the software opens a drawing, the distance between connected items is
either too long or too short, which results in an inappropriate display of connectors. To control
the visual consistency of connectors, you can set a Clearance value that specifies the amount
of space that the software will maintain between the connector and the connected element
(also known as range avoidance). This action allows you to control the visual consistency of
connectors that make right-angle turns just before they attach to a symbol.
To set Clearance, select a connector and then type the minimum distance from the symbols
where you would like the first turn in the connectors to occur. Note that the default setting is
zero.
343
SECTION 21
Create a Signal
This procedure explains how to create a signal in SmartPlant Electrical. After creating the
signals, you publish the signal data to SmartPlant Instrumentation.
1. In the Electrical Index, expand the folder hierarchy by clicking the + icons or by doubleclicking the folders.
2. Do one of the following:
Navigate to one of the Loads folders and select an item.
Navigate to one of the Converting Equipment folders and select an item.
Expand the hierarchy Power Distribution Equipment > Disconnect Electrical
Equipment, then navigate to one of the folders and select an item.
Expand the hierarchy Power Distribution Equipment > Power Distribution Boards
and select a circuit.
Expand the hierarchy Wiring Equipment > Panels > Control Stations and select a
control station.
3. Right-click the selected item, and then click New Signal.
4. Edit the signal properties in the Properties window as required.
Some of the properties that you can edit include Item Tag, Tag Prefix, Tag Suffix,
Description, Sequence in Group, and System I/O Type; there are other properties that belong
to SmartPlant Instrumentation and are read- only.
You can also create signals for an item by dragging a typical I/O set in the Reference Data
Explorer onto the item in the Electrical Index.
344
345
SECTION 22
Customizing Symbols
Symbology provides graphical clarity to a drawing by differentiating among various items by their
appearance. Symbology refers to the color, line width, shape, and style associated with items.
You can use line widths, styles, shapes, and color to differentiate among the different types of
drawing items, such as cables, power distribution boards (PDB), equipment, bus ties and their
internals, and so forth. For example, you could define a power cable that connects to a PDB as
being a black, 2-mm thick continuous line, where as a control cable could be a blue, 1-mm thick,
broken line.
Along with the default symbols supplied with the software, you can create your own customized
symbols that can be associated with a document and item tag.
The three different types of documents, SLDs, PDBs, and Wiring, support the use of multiple
symbols for the same item by the use of filters, so that a DC motor can be displayed differently
than an AC motor in the same drawing.
In order for the software to rescale all the items correctly, make sure that when
creating symbols that contain text or smart text, the Units space property is set to World. Note
the World is not the default setting for this property.
Using symbology you can customize the style of the PDB frame, add and change the macros, and
change their position in relation to the frame.
You must create your custom symbols in the Catalog Manager before using them in SmartPlant
Electrical.
For more details, see Creating Symbols in the Catalog Manager User's Guide, under Catalog
Manager > Working with Symbols > Creating Symbols.
347
Customizing Symbols
6. Click OK.
You can only choose symbols that are stored in the default folder, and its sub-folders. You
set the symbols default folder in the SmartPlant Electrical Options Manager. For more details,
see Defining File Locations in the SmartPlant Electrical Option Manager Users Guide, under
Using Options Manager, Defining File Locations, Defining File Locations.
348
SECTION 23
349
7.
8.
9.
10.
11.
The Annotation locking and Move independently properties are only available if you
first selected an item tag before inserting text.
Click the Properties tab.
In the Horizontal and Vertical lists, select options to align text within the text box boundaries.
Select Show border if you want to display the text box border.
To rotate the annotation text box, do one of the following in the Rotation box:
Enter a positive value in degrees to rotate the macro attribute or label clockwise (CW).
Enter a negative value in degrees to rotate the macro attribute or label counter-clockwise
(CCW).
From the Orientation list, select a text box orientation if needed.
350
Delete Annotations
1. Open an appropriate drawing.
2. Select an annotation item on the drawing sheet.
You can select several items at a time. To do so, hold the CTRL key and click each
item. The font and border color of the annotations change when you select them.
3. Press the DELETE key.
4. Click File > Save.
When you delete an annotation, it is not pasted to the Clipboard and you cannot reinsert
it. You cannot restore a deleted annotation after you have saved the file.
You can type an unlimited number of lines with up to 28 characters on each line.
Select Set as watermark if you want to define the text as a watermark that appears in a layer
under other drawing items.
Click the Properties tab.
In the Horizontal and Vertical lists, select options to align text within the text box boundaries.
Select Show border if you want to display the text box border.
351
352
7.
8.
9.
10.
11.
When you modify an annotation, the option Set as watermark is not available. You can
set this option only when defining the text properties for the first time.
Click the Properties tab.
In the Horizontal and Vertical lists, select options to align text within the text box boundaries.
Select Show border if you want to display the text box border.
To rotate the annotation text box, do one of the following in the Rotation box:
Enter a positive value in degrees to rotate the macro attribute or label clockwise (CW).
Enter a negative value in degrees to rotate the macro attribute or label counter-clockwise
(CCW).
From the Orientation list, select a text box orientation if needed.
Delete Redlining
1.
2.
3.
4.
5.
When you delete redlining, it is not pasted to the Clipboard and you cannot reinsert it. You
cannot restore a deleted redlining item.
353
SECTION 24
Drawing Items
With SmartPlant Electrical, you can generate schematics and single line diagrams (SLDs). After
generation, you can view or manipulate the drawings before saving them. Among the options
available to you are:
Viewing Drawings (on page 356)
Finding Drawings (see "Find a Drawing Item in the Electrical Index or Electrical Engineer" on
page 355)
Aligning Objects (see "Aligning Drawing Objects" on page 357)
355
Drawing Items
A new window opens showing the open folders of the selected item and all the related items,
you can then drag and drop these items onto your CBD in the same way as from the Electrical
Index or Electrical Engineer.
To close the Related Items window, double-click on the blue title bar at the top of the window
and then click on the close icon.
Viewing Drawings
When you generate or open schematics or single line diagrams, you can zoom and pan the
diagram to view the areas of interest to you.
Zoom Area
To zoom in on a selected area, click Zoom Area on the main toolbar.
To select the area to zoom, drag over the area. You can redefine the zoom area position and
dimensions by moving the mouse pointer while continuing to hold down the mouse button.
Zoom In
To zoom in on a selected area, click Zoom In on the main toolbar.
Click over the area where you want to zoom in. The point where you click becomes the center of
the zoom-in area.
Zoom Out
To zoom in on a selected area, click Zoom Out on the main toolbar.
Click over the area where you want to zoom out. The point where you click becomes the center of
the zoom-out area. For
Fit
To fit the drawing on the visible display area, click Fit on the main toolbar.
If you change the size of the display area, you must click the command again to make the drawing
fit the modified display.
356
Drawing Items
Pan
To view different parts of the drawing in the visible display area, click Pan on the main toolbar.
You can move the drawing in the display area as required.
Gapping Lines
A gap in a drawing is a condition that exists when two lines intersect graphically in the drawing but
not physically in the plant. In order to portray this condition, you can choose that lines show a gap
at these non-physical intersections. This can help the clarity of your drawing considerably.
Gapping is carried out automatically when you open an existing drawing. If you want to perform
gapping on a drawing that is already open, you must use the command Tools > Gap Now.
357
Drawing Items
In the following illustration, the objects are aligned by their left sides:
The objects in the select set are moved horizontally from the place where they are selected until
they are aligned with the left edge of the leftmost object in the select set.
If two objects are horizontally near one another, one of the objects may be placed
behind another object. To avoid this, make sure that the items you select are never to the left or
right of one another when you use vertical alignment.
358
Drawing Items
In the following illustration, the objects are aligned horizontally by their tops:
The objects in the select set are moved vertically from the place where they are selected until they
are aligned with the top edge of the top-most object in the select set.
If two objects are vertically near one another, one of the objects may be placed
behind another object. To avoid this, make sure that the items you select are never to the top or
bottom of one another when you use horizontal alignment.
To select more than one object, hold down the SHIFT or CTRL key and click each object.
2. Click Align
359
Drawing Items
3. On the Align Ribbon (on page 828), click the button that corresponds to the alignment type
you want.
When you use horizontal alignment, make sure the selected objects are not to the top or
bottom of one another.
If two shapes are vertically near one another, one of the objects may be placed behind another
object.
When you use vertical alignment, make sure the selected objects are not to the right or left of
one another.
If two shapes are horizontally near one another, one of the objects may be placed behind
another object.
Alignment features only line up objects; they do not distribute an equal amount of space
between aligned objects.
You cannot align items that are glued to other objects, including labels and symbols.
Align Command
Allows you to align two or more objects in a select set. You can create a select set by clicking
Select Tool
on the Main toolbar and dragging a fence around the items you want to
include. To select more than one object, hold down the SHIFT or CTRL key and click each
element.
The six align options provide the flexibility of arranging objects with less dragging.
You cannot align items that are glued to other objects, including labels and symbols.
360
Click Move
on the Change Toolbar (on page 829) and then move the cursor to
another location in the drawing.
Drag an item without using the Move command. Select the item and then drag it to its new
location. If you want to copy the item, press CTRL while you drag it.
If you move an item that owns other items, the owned items move also.
You can use other view manipulation commands, such as Zoom, Fit, and Pan, while you are
using the Move command. When you finish manipulating the view, the software returns you to
the Move command at the point where you were when you started manipulating the view.
Drawing Items
Instead of positioning the mirror axis dynamically, you can use the Position Angle box on the
Mirror Ribbon (on page 362).
You can use other view manipulation commands, such as Zoom and Pan, while you are using
the Mirror command. When you finish manipulating the item, the software returns you to the
Mirror command at the point where you were when you started manipulating the item.
361
Drawing Items
Mirror Ribbon
Appears on the main toolbar when the Mirror command is active, and allows you to either specify
mirroring options or to observe mirroring options.
Copy Copies the item or items when you mirror them.
Position Angle Sets the angle of the mirror axis. The origin of the angle measurement is the
point that you clicked for the beginning of the mirror axis. Setting the position angle to zero
extends the axis horizontally to the right of the screen, 90 extends the axis vertically to the top, 180
extends the axis horizontally to the left, and 270 extends the axis vertically to the bottom.
To determine the option name on the ribbon, pause over an option and read the ToolTip.
The software dynamically displays the rotation axis and items being rotated. The location
and position of the rotation axis defines the rotation from point.
5. Rotate the items into position by dragging the rotation axis.
6. Click to define the rotation to point.
To rotate by arbitrary increments, type a value in the Step Angle box on the Rotate Ribbon (on
page 362).
In order to copy the rotated items into the new position, you can hold CTRL while you click to
define the to point.
You can use other manipulation commands, such as Zoom and Pan, while you are using the
Rotate command. When you finish manipulating the item, the software returns you to the
Rotate command at the point that you were when you started manipulating the view.
Rotate Ribbon
Appears when the Rotate command is active, and allows you to either observe rotation options as
you rotate an item or specify rotation options.
Copy Creates a copy of the item that you are rotating.
362
Drawing Items
Position Angle Displays the angle between the horizontal axis through the center of rotation
(A) and the point that you rotate from (B). Then, if you rotate the item, the position angle (C)
changes to become the angle between the horizontal axis and the point to which you rotate. The
position angle is always a positive value measured counter-clockwise from the axis.
Rotation Angle Defines the rotation angle. The rotation angle is the angle between the point
from which you rotate and the point to which you rotate. In the following picture, the center of
rotation (A) shows the point (B) from which you rotate the item.
The rotation angle (C) is the angle of change between the old and new positions of the rotated
item. The value is always positive.
Step Angle Specifies the rotation step angle. The step angle specifies the increments, in
degrees, that an item rotates on a rotation axis. You can enter increments in the Step Angle box.
For example, if the box is set to 30.0, the rotation is displayed in 30 degree increments. The
default setting is 0 degrees so that the rotation is fully dynamic.
The mirror handle allows you to mirror about the horizontal and vertical axes, defined in
relation to the origin of the item. You can mirror items by dragging the mirror handle in the
appropriate direction. The software shows you the result of the operation dynamically so that
you can be sure to mirror the item correctly.
The rotate handle provides a mechanism for rotating components around their origin. You
can rotate items by dragging the rotate handle in the appropriate direction. The software
shows you the result of the operation dynamically so that you can be sure to rotate the item
correctly.
For more information, see Working with Labels in the SmartPlant Engineering Manager Users
Guide.
363
Drawing Items
364
Align Center About Vertical Align labels so that their center points agree on a
horizontal line
Align Center About Horizontal Align labels so that their center points agree on a
vertical line
SECTION 25
If you type a value that does not comply with the current revision method, the next time
you add a new revision, the software starts a new numbering. For example, the selected
revision method is P0, P1, P2 and the last revision is P3. If you add a new revision
number RRR and then another one using the P0, P1, P2 method, the software displays
the newly added revision as P0.
If you type a value that complies with the numbering method but the value is not
sequential, the software increments the number of the next revision that you add. For
example, the selected revision method is P0, P1, P2 and the last revision is P3. If you
add a new revision number P1, the software will increment the following revision to P2.
365
You can delete a selected revision by highlighting a row and clicking Delete. The software
updated the revision numbers automatically if the subsequent revision number complies with
the selected revision method.
Using the Data Dictionary Manager, it is possible to determine which fields are available on the
Revisions tab. For details, see Data Dictionary User's Guide > Modify Properties of
Database Tables.
366
The software displays clouds around the items that differ from the current data. The last
revision number is shown in a triangle beside the cloud.
The software uses index numbers to identify the changes in associations between electrical
items.
The software generates a tabular report where it shows all the changes and shows the
changes in associations using index numbers as they appear in the drawing.
For registered reports, the software opens two Excel files. One of the Excel files displays
changed data with a blue shading. The second file is a summary of all changes and it is called
Registered Comparison Report. This report displays the previous and current data for
each tag that has undergone a change. Note that you can compare a registered report only if
this is a simple tabular report.
367
368
The software compares the current data with the last saved revision.
In SLDs and schematics, the software displays clouds around the items that differ from the
current data.
The software uses index numbers to identify the changes in associations between electrical
items.
The software generates a tabular report where it shows all the changes and shows the
changes in associations using index numbers as they appear in the drawing.
In SLDs, the software indicates the following changes:
All added and deleted electrical items except for control stations.
Added, deleted, and updated properties of electrical items.
Changes in associations.
Attachment to a different document template.
In schematic drawings, the software indicates the following changes:
Added, deleted, and updated properties of electrical items.
External Documents
External documents are external files that you associate with electrical items in the
software. These files can be reference documents or drawings, such as a general specification
number, requisition number, vendor document, civil or structural document, site layout drawing,
an electrical communications drawing, and so forth.
The software allows you to create a document reference repository that stores all the document
references in your system. You can add external file references to your document repository or
just create references that you can link to external files later. It is possible to display all the
documents associated with a selected electrical item classified according to document category
and type. Also, you can associate documents with multiple items if needed. Note that if you
delete an electrical item that is associated with an external document, the software deletes the
external document association automatically.
You do not have to associate a document reference with an external file. You can do
this at some other time when needed.
8. On the Select File dialog box, select the desired file.
9. Click Apply to store the document reference in the database and select another document
category if needed.
369
3.
4.
5.
6.
You can also associate multiple electrical items with the same external document. In
the Electrical Index, click a folder that contains electrical items and highlight in the list view
pane the items that you require.
Click Actions > Associate Document.
On the Associate Documents dialog box, under Filter by, select a document category and
type from the lists.
Click Add.
On the Find dialog box, click Find Now to display the available documents.
The Find dialog box finds only those documents that belong to the document category
and type that you select on the Associate Documents dialog box.
7. Select each document that you want to associate with the selected item and then click Apply.
To associate documents belonging to another category or type, return to the Associate
Documents dialog box, select the desired document category and type, click Associate again,
and repeat the succeeding steps in this procedure.
370
371
button
to select a template that you require.
Under Document number, type a document name. Note that this is a required field.
Type a short description if needed and click OK.
In the drawing that opens, to insert a symbol, click Edit > Insert > Symbol.
On the Select Symbol File dialog box, select a symbol and click OK.
To place the symbol in the drawing, position the cursor in the open drawing and then press the
left mouse button. Note that the cursor marks the symbol origin (the left bottom corner).
372
After saving a miscellaneous document, you can set the appropriate revisions as you
require. For details, see Add a Document Revision (on page 365).
You can associate an electrical item with a miscellaneous drawing. For details, see Associate
External Documents with Electrical Items (on page 370).
Tabular Editor
Tabular Editor
You use the Tabular Editor for viewing and performing editing or other operations on one or more
items of a specified item type.
The Table Properties dialog box (on page 816) allows you to define the items you want to see in
the table view. You customize a filter and layout for the display on the Advanced Table
Properties dialog box (on page 813).
The main features of the Tabular Editor are:
Header
The header displays the following information:
Total count - The total number of rows (tags) that your table contains. Filtering does not change
this value.
Item type - The item type on which your table is based.
Layout - The layout name that your table uses to determine which properties appear, and their
order.
Tabular editor layouts are limited to 350,000 cells. It is highly recommended that you
work with filtered layouts to avoid the creation of numerous cells that you might not need.
Data
You can populate data viewed in the table in one of the following ways:
Selecting a table cell and typing the appropriate information.
If the property has a select list associated with it, then you choose the value from the select list.
If the cell is populated by a value that results in calculating another cell, the software performs
the calculation and displays the result in the appropriate cell.
If the cell is populated by a read-only property or a property that is only automatically generated by
validation or calculation, you cannot edit that cell. You can select an entire row, corresponding to
the properties of a single item tag, by clicking the corresponding row number to the left of the
table. Then you can view the properties in the Properties window and edit item properties there,
too.
The contents of cells can be copied to other cells, provided the cell contents are compatible.
Data Manipulation
You can perform the following operations in the Tabular Editor:
Move a cell from one location to another like in Excel.
Change the width of a cell by dragging the edge of the cell header and making the cell wider or
narrower. When you save the settings, the software retains cell widths the next time you open
the layout.
Freeze one or more columns to prevent them from scrolling. Click a column header to select
the column, then right-click in the table and select Freeze Panes on the shortcut menu. The
software prevents all the columns to the left of the selected column from scrolling horizontally.
Double-click a cell to select its contents for editing.
Click a cell once to select the entire row for copying or pasting data.
For a multiple selection using the TAB or CTRL keys, click the relevant row numbers.
Click the upper left empty header to select all the items.
373
Tabular Editor
Printing
You can print out the contents the current table. The software opens a print preview in Microsoft
Excel that allows you to view and print out the data. For more details, see Print Tabular Editor
Content (on page 379).
When navigating in the Tabular Editor, the Properties window is enabled. When you select
a tag in the Tabular Editor, the data for the tag appears in the Properties window. Editing a
property of a tag in the Properties window is immediately reflected in the Tabular Editor and
vice versa.
The Properties window can display data for either the Tabular Editor or for one of the
windows where you select an item (Reference Data Explorer, Electrical Index, or Electrical
Engineer). If you select more than one tag in the Tabular Editor, the Properties window can
display common properties when you choose Select Set from the list at the top of the window.
After exiting SmartPlant Electrical, and starting a new session, the software retains the size
and position of all the windows that were open in the previous session.
When tabbing through the cells of a Tabular Editor work sheet, pressing F4, when a select
list field is highlighted, displays the select list contents. You can then use the arrow keys to select
the desired item.
When you create a Tabular Editor view for abstract item types such as loads or converting
electrical equipment, as opposed to specific item types such as motors or transformers, the
software displays all the common properties for these item types in the Tabular Editor. With
loads, for example motors and heaters both appear, but the software cannot display their
specific properties in one common Tabular Editor view. However, when you select items of
the same specific type, all of the properties appear in the Properties window.
If you do not find a filter you want under Filter, you can define a filter on the Filter tab of the
Advanced Table Properties dialog box. Open the Advanced Table Properties dialog box
by clicking Advanced on the Table Properties dialog box.
If you do not find a layout you want under Layout, you can define a layout on the Layout tab of
the Advanced Table Properties dialog box. Open the Advanced Table Properties dialog
box by clicking Advanced on the Table Properties dialog box.
To modify an existing table, right-click in the table and select Edit View to open the Table
Properties dialog box.
To print out the contents of an open table, right-click in Tabular Editor and then on the shortcut
menu, click Print or Print Preview. For details, see Print Tabular Editor Content (on page
379).
374
Tabular Editor
6.
7.
8.
9.
You can use an operator with a property that has a value with a unit of measure. For
example, you can filter a table showing motors to show only those motors that have the brake
power value greater than the value you set in the filter.
To add more entries, repeat steps 4 and 5.
Click Delete if you want to delete the current row in the Definition box.
Click either Match all or Match any.
Click OK on the Advanced Table Properties dialog box and again on the Table Properties
dialog box so that the software can populate your table.
After you have defined a specific filter for your Tabular Editor, you can save that
definition. For details, see Save a Tabular Editor Layout (on page 377).
375
Tabular Editor
4. Click Save if you want to save the layout in order to apply it to another Tabular Editor, click
Delete if you want to delete the layout.
5. To further define a layout, populate the Definition box with display and sort properties.
6. Click Add to add a line entry to the Display Property list. Then specify the property and
caption in the Edit group at the bottom of the dialog box.
To add and define more display properties, repeat step 5.
To change the display order of the columns in the Tabular Editor, select a row in the
Display Property box and click Move Up or Move Down.
7. In the Sort Property list click Add to add an entry. Then select the property, order, and type
in the Edit group at the bottom of the dialog box.
To add and define more sort properties, repeat step 7.
To change the sort order of the properties in the Tabular Editor, select a row in the Sort
Property box and click Move Up or Move Down.
The Add, Insert, Delete, Move Up, and Move Down buttons apply to the active list
view, which can be either Display Property or Sort Property.
376
Tabular Editor
6. Define a New Layout for a Tabular Editor View (on page 375).
7. Click OK on the dialog box to display the modified view.
After defining a layout, you can save it if you want to apply it to another Tabular Editor view. To
save the view layout, specify a name in Name and click Save on the Advanced Table
Common Properties Layout tab.
You can also name and save the entire Tabular Editor view, layout and all:
Save a Tabular Editor Layout (on page 377)
You can edit some of the properties of those items that appear in the Tabular Editor. You can
edit the contents of some cells directly in the Tabular Editor if the corresponding property is not
read-only or generated strictly by validation; you can copy, cut, and paste properties too, with
the same restriction, or you can click on the row number to the left of the Tabular Editor to
select an item and edit its properties in the Properties window.
After you have customized the Tabular Editor, on the Tabular Editor Property dialog box,
Layout tab, click OK.
You can delete a saved view, too. For more details, see Delete a Tabular Editor Layout (on
page 377).
The Tabular Editor is where you can display database items.
You can customize the Tabular Editor. For more details, see Modify the Table Properties of
an Existing Tabular Editor View (on page 376).
Right-click inside the Tabular Editor and on the shortcut menu, click Refresh.
The database can change at any time. The software does not update the Tabular Editor
automatically: you must update it by using the Refresh command manually.
377
Tabular Editor
To match a single value, choose that value from the list that is displayed.
To display rows that meet two conditions, choose Custom from the list. The Custom
AutoFilter dialog box opens. Enter the comparison operator and value you want, and
then click the And button. In the second comparison operator and value boxes, enter the
operator and value you want.
To display rows that meet either one condition or another condition, enter the comparison
operator and value you want, and then click the Or button. In the second comparison
operator and value boxes, enter the operator and value you want.
You can also choose Blanks or NonBlanks from the list in order to display items that
either have no value in the column or do have a value in the column, respectively.
Since properties with units of measure are strings, you cannot perform mathematical
operations on these type of properties.
378
Tabular Editor
379
SECTION 26
3.
4.
5.
6.
7.
8.
9.
10.
11.
If you select the Blank template, the file format for Excel 2007 and higher is Excel
Macro-Enabled Workbook (*.xlsm). For Excel 2003, the file format is Microsoft Excel
Spreadsheet (*.xls).
Under Name, type the report name.
Select an appropriate item type for which your report will be used.
Select an appropriate report format: fixed, tabular, or composite. For details, see New
Report Template Dialog Box (on page 783).
Click OK.
On the SmartPlant Electrical menu bar, click Reports > Edit and select your new report to
edit in MS Excel.
Edit your report headers as you require. For details, see Define Report Headers (on page
397).
Edit your report contents. For details, see Define the Contents of Your Report Template (on
page 398).
To open your new report, click Reports > My Reports.
Select your report from the My Reports list and click OK to open it in Microsoft Excel.
381
You must have Microsoft Excel installed on your computer to display reports.
When creating a report based on the Blank template, the Excel file format of the Blank
template is XLSM for Office 2007 and Office 2010, for Office 2003, the file format is XLS.
The software stores the reports that you generate on your local computer in the Windows
directory under \Profiles\<username>\My Reports\Output.
Shipped Reports
SmartPlant Electrical provides you with a number of predefined reports. You can use these
reports as templates for any other reports. You can define your own sort and filter settings. Also,
you can use sort, filter or other queries to create new reports.
Note that if you do not select particular items in a table that you open in the Tabular Editor, the
software generates a report that includes all the tags belonging to the item type that the report is
based on.
Every time you generate a report, the software retrieves the relevant data from the database and
calculates the pertinent results based on the currently retrieved values. The software does not
store the report and the calculation results in the database, but rather in the Excel file that the
software creates after generating the report. The software recalculates the values every time you
generate the report. Therefore, the report displays the data only as it exists at the time of the
report generation. You can then save the report as an external Excel file if needed.
Note that there are hidden columns and Visual Basic code in the templates of these reports. Be
very careful when editing a template or a report, as this may render your report unusable.
The following reports are available:
382
383
384
The report groups and sorts the loads according to their associated PDB.
The software sums the electrical quantities to provide the total running load and the total peak
load based on the coincidence factors that has been defined for each load.
Under each PDB in the report, the software sorts the loads according to their bus association
and then alphanumerically under the bus.
The software does not filter out any specific PDB. If you do not filter the PDBs, the software
lists all the existing PDBs. To create a report for a specific PDB, use an appropriate
filter. The software displays each PDB on a separate page. The first page is reserved for
those loads that are not associated with a PDB.
The report multiplies each electrical load by its coincidence factor (x, y, z or zz).
Based on the total kW and KVA values, the software calculates the needed power factor in the
report.
The software does not store the report and the calculation results in the database, but rather in
the Excel file that the software creates after generating the report. The software recalculates
the values every time you generate the report. Therefore, the report displays the data only as
it exists at the time of the report generation. You can then save the report as an external
Excel file if needed.
For associated capacitors, the software subtracts the rated kVAr value of the capacitor from
the total connected rated kVAr value. Therefore, the rated electrical power ( kVAr) may
display a negative value. This means that there is a lagging power factor.
When localizing the software, do not translate the values (Continuous, Intermittent,
Standby, and Spare) that appear in the Operating Mode list of the Data Dictionary. The
software will not be able to perform some of the calculations if these values are changed.
It is also possible to generate a PDB load summary for a freestanding bus.
To customize this report VB programming skills are required.
385
Cable Take-Off
Cable Take-Off is a report that provides a summary of all the existing project cable types, including
the cables that haven't been sized yet.
The report specifics are as follows:
Provides technical details about the cable types.
Calculates the total estimated and design lengths of each cable type.
Calculates the lengths of single core conductor configuration cables based on the number of
conductors of each cable.
Provides estimated cable lengths both in meters and feet.
Allows you to expand each cable type to view the individual cable tags.
Cable Schedule
Cable Schedule is a report that lists all the existing project cables.
This report provides the following information:
Cable tag names
Cable types
Estimated and design cable lengths
Store part numbers
Cable origin and destination sides (the To and From cable sides). The To and From
information includes the tag of the electrical item that the cable is associated with. If one of
the cable sides is assigned to a PDB, the report displays the path of the circuit tag: PDB/
bus/(cell)/ circuit.
If you are generating a cable schedule report for a cable that is connected to an auxiliary
contact, the cable schedule report will display the full connection path:
PDB > Bus > Cell > Circuit > Circuit internal disconnect electrical equipment > Auxiliary
contact
Or
Stand-alone disconnect electrical equipment > Auxiliary contact
386
387
You can use the Segment Width Estimate report for calculating the tray widths and number of
layers needed so that you can select appropriate reference cableway components.
Displays the quantity of items required for each type of reference cableway component when
ordering items from the manufacturer.
Displays the list of cables in each cableway segment that makes up your cable routing.
Segment Fill
Displays the fill status and tray loading for each segment and indicates whether or not the
segment is overfilled.
PDB Schedule
PDB Schedule is a report that you generate based on the circuit item type. The report
specifics are as follows:
The report lists, for all the power distribution boards in the current plant, all the circuits, loads,
circuit internal components with the technical details of each circuit.
The report includes the associated schematic drawings.
The report uses a predefined filter to display the associated schematic drawings. To
customize this report VB programming skills are required.
It is also possible to generate a PDB schedule for a freestanding bus.
388
Power Distribution Panel Schedule is a report that is intended for single phase loads
connected to distribution panels. The report specifics are as follows:
The report lists, for all the power distribution boards in the current plant, all the circuits,
each with its protection device type and current rating (the software supports a single
protection device per circuit) and the loads associated with each circuit.
The report sorts the circuits by phase and then by circuit (all the circuits for phase 1, then
phase 2, and then phase 3).
The report calculates the following: Full load current for each phase, Total load current of
the bus, Total kW per phase, Total kW per bus.
This report is not suitable for PDBs that include 3-phase loads.
To customize this report VB programming skills are required.
389
Electrical items are included in calculations if they are defined as consumers. In addition to
loads, you can define converting equipment items, cabinets, local panels, and junction boxes
as consumers. To define an electrical item as a consumer, you have to set the Is Load
property in the Properties window for that item to True or define the electrical item as a
Consumer in the relevant Common Properties dialog box.
If you define a converting equipment item, local panel, or junction box as a consumer and
perform a drill-down calculation, the software uses the rated and consumed electrical load
values of the equipment as the load values, the software ignores the entire branch that is
connected downstream from the equipment. Note that you enter the pertinent rated and
consumed electrical load values on the Common Properties dialog box of the equipment
item.
If you create a circular network that contains several buses that feed other common
downstream buses, the report will display a larger than expected value for the total of the
circuits. In a circular network, each of the circuits includes common loads and, consequently,
the total of the circuits is reflected in the summation of the common loads.
To prevent this from happening, disconnect one of the circuits that feeds the downstream
buses.
The circuit totals that are shown in the Bus grid of the report do not account for transformer
losses. The bus totals, however, do account for these losses.
It is also possible to generate a report for a freestanding bus.
You can customize this report as needed. (Note that VB programming skills are required.) For
detailed information about customizing this report, see the SpelCalcInf.chm file, which is
located in the home folder where your SmartPlant Electrical is installed, for example C >
Program Files>SmartPlant>Electrical>Program\resdlls>0009>SpelCalcInf.chm.
390
Registering Reports
When you create an Excel report in SmartPlant Electrical, you can enable revisions for the report
by registering it. If you create a report for an item type where the data can be published, for
example, instruments, cabinets or signal runs, you also need to register the report and enable
publishing. When you register a report, it appears under Documents > Registered Reports in
the Electrical Index. Note that you can associate an electrical item with a registered
report. Also, you can compare the current data with the data in an archived revision of a simple
registered report.
Register a Report
1. Click Actions > Register Report.
2. On the Registered Report Common Properties dialog box, beside the Report template
box, click the ellipsis button
You can create a custom report or select one of the reports that is shipped with
SmartPlant Electrical. For the full list of shipped reports, see Shipped Reports (on page
382).
In the Select Report window, you can select the XLS or XLSM file extension from the list
beside the File name list.
3. If you want to filter the data that appears in the report, beside Filter, click the ellipsis button
and select a filter that is suitable for the report template. For details of how to create or
modify a filter, see Filter Manager Online Help.
4. Select a value from the Document main item type list if needed.
This value is for information purposes only.
5. Type a name for the document, and if required, a description.
6. To use the report for publishing data to an XML file, select Enable document for publishing.
A report that you register can display revision numbers after you archive the report.
The registered report with its filter defines the exact scope or subset of data to be published.
You can view the layout of this report and the properties that are included in the report when
you open the report; however, the actual data (properties) to be published with each item is
defined in the code.
391
7. Press ENTER.
8. After adding all the desired revision data, save the Excel template.
392
By
Date
RevisionNumber_1
CreateBy_1
RevisionDate_1
RevisionNumber_2
CreateBy_2
RevisionDate_2
RevisionNumber_3
CreateBy_3
RevisionDate_3
RevisionNumber_4
CreateBy_4
RevisionDate_4
Prior to carrying out the following procedure, you have to select the Trust
access to VBA project object model check box in your Microsoft Excel Options. To do
this, in Excel Options, click Trust Center > Trust Center Settings > Macro Settings >
Trust access to VBA project object model.
The following procedure provides the instructions for enabling this special Excel add-in and saving
the free text.
1. On the SmartPlant Electrical menu bar, click Reports > Edit.
2. Select the template that you require and click Open.
3. In the report template, do the following to add a property that holds a unique value. For
example, the ItemTag property (Motor_1, Motor _2, and so forth.)
a. In Microsoft Excel, click
on the SmartPlant Reports toolbar.
b. On the Define Report Contents dialog box, select the item type for which the new report
is intended and click Define.
c. On the Define Report Item dialog box, from the Available properties list, select any
unique property and click the right arrow to add it to the Selected properties list and click
OK.
We recommend that you select SP_ID because this property is known to be unique.
d. Close the Define Report Contents dialog box.
e. In Microsoft Excel, click in any available cell where you want the selected property (for
example, SP_ID) to appear.
f. Click Map Properties on the SmartPlant Reports toolbar and point to the item type for
which the current report is intended.
g. From the list of the selected properties for this report, click the property that you selected
(for example, SP_ID) to place this property in the selected cell.
h. Click in the Name Box of Microsoft Excel and type Item_ID to name the cell that holds the
selected property (for example, SP_ID).
Note that Item_ID is the only name that is available in the Excel Name Box. It does
not actually matter where you place this cell as long as it exists in the report template.
4. For existing reports, add the following VB code in the report template:
a. In the report template (Microsoft Excel), press Alt+F11.
b. Under VBAProject, double-click ThisWorkbook.
c. In the General declaration section, add the following string:
Public m_objXLAgent As Object
d. Locate the Public Sub BeginReport(vParam As Variant) string and then type the following
underneath:
Set m_objXLAgent = vParam
e. Save your changes and close the template.
393
3.
4.
5.
6.
7.
You can also associate multiple electrical items with the same registered report. In the
Electrical Index, click a folder that contains electrical items and highlight in the list view pane
the items that you require.
Click Actions > Associate Document.
On the Associate Documents dialog box, under Filter by, under Document category,
select Electrical Documents. This selection determines the available options in the
Document type list. You can define and customize document categories in the Data
Dictionary Manager.
From the Document type list, select System Reports.
Click Add.
On the Find dialog box, click Find Now to display the available documents.
The Find dialog box finds only those documents that belong to the document category
and type that you select on the Associate Documents dialog box.
8. Select each document that you want to associate with the selected item and then click Apply.
To associate documents belonging to another category or type, return to the Associate
Documents dialog box, select the desired document category and type, click Associate again,
and repeat the succeeding steps in this procedure.
394
You can create a new report template based on an existing template by specifying a
source template also. For more information, see Create a Report Template Based on an
Existing Template (on page 396).
Since delivered reports are all in tabular format, you must choose Blank if you want a
fixed or composite format report template. You can select Blank for a tabular format
report template, nonetheless.
3. In the Name box, type a meaningful name to describe the report template you are creating.
This entry is the name of your Microsoft Excel workbook. When you save the template,
the software appends .xls to the name.
4. In the Item type box, select an item type.
5. In the Report type box, choose template format.
These options are only available when you choose Blank from the Source template list.
6. In the Description box, type a description for the template.
7. If you want this template to be available at the plant-level, select the Add to plant reports
option.
You must have the appropriate permissions, granted in SmartPlant Engineering
Manager, to create plant-level report templates.
8. Click OK to create the template.
9. When the software gives you the option to edit your new template in Microsoft Excel, click OK
and define the layout and contents of the template. For more information about these
procedures, see the following topics:
Define the Layout of a Tabular Format Report Template (on page 400)
Define the Layout of a Fixed Format Report Template (on page 402)
Define the Layout of a Composite Format Report Template (on page 402)
Define the Contents of Your Report Template (on page 398)
395
3.
4.
5.
6.
In the list, the software displays all report templates with unique names. If templates
with the same name exist having .xlsm and .xls formats, the software displays only one of
these templates in the format that depends on the installed version of Excel: .xlsm for Excel
2007 and .xls for earlier versions of Excel.
In the Name box, type a name for the new report template.
In the Description box, type a description for the new report template.
Click OK.
When the software gives you the option to edit your template, click OK to open Microsoft
Excel and define the contents and layout of your report. For more information about these
procedures, see the following topics:
Define the Layout of a Tabular Format Report Template (on page 400)
Define the Layout of a Fixed Format Report Template (on page 402)
Define the Layout of a Composite Format Report Template (on page 402)
Define the Contents of Your Report Template (on page 398)
396
If you are working with Excel 2007 or higher and your report template is based on
Excel Macro-Enabled Workbook (*.xlsm), you cannot use the words "BUS" and "PDB" as
column names because these words are reserved names in Microsoft Excel. If you need to
use these words as headers, we suggest that you add another character or a number to the
text, for example BUS1.
For more details about reserved words in Microsoft Excel, see
http://technet.microsoft.com/en-us/library/cc179188(office.12).aspx
(http://technet.microsoft.com/en-us/library/cc179188(office.12).aspx).
7. Press ENTER.
8. After adding all the desired data, save the Excel template.
To include the properties of a document in your report, add the following macro to the
template:
d_attribute name (For example: d_ItemTag or d_Description)
You can add plant and plant group column headers to your templates. Use the following
macros to show plant and plant group names. Note that all macro names are case-sensitive:
Plant.Name
Area.Name
Unit.Name
Unit.<custom property>
You can use custom properties to add client information.
397
When you click New on the Define Report Contents dialog box, you can choose from
only those items which are related to the item you selected in the Report on hierarchy.
The highest node in the Report on hierarchy that you can add a new item under is the
node that belongs to the report item type that you base your template definition on. You
can add items under any nodes subordinate to the main report item type as long as they
have items related to them.
Using the New command skillfully allows you to navigate in all directions in the plant
hierarchy and gather properties from throughout the plant database.
3. On the New Items dialog box (on page 782), select the new item you want to add to the
hierarchy.
4. You can change the name of the item that is displayed in the hierarchy by typing your choice
in the Name Box.
If the item you choose has the same name as an item elsewhere in the hierarchy, you
must type a different name for it in the Name box.
5. Click Apply.
6. When you have added all the items you want from this list, click Close.
If you want to add more new items under another node in the hierarchy, choose that
node and repeat steps 2 through 5.
7. On the Define Report Contents dialog box, select an item whose properties you want to be
available for your report template.
8. Click Define.
9. On the Properties tab of the Define Report Items dialog box, choose the properties that you
want to be available to map to your report template.
If you want to sort the order in which your items are listed when you generate a report,
choose the property or properties to sort on by using the Sort tab.
If you want to change the filter that finds your report items, use the Filter tab. For instance,
you may want to change from a filter that displays all pumps to using a filter that displays
only active pumps.
10. Click OK. The Define Report Contents dialog box remains open, and so you can repeat
steps 2 through 9 to continue adding more items and specifying their properties.
398
All the properties you have specified to be available to map into your template are now
displayed when you click Map Properties on the SmartPlant Reports toolbar. Now you can
use the properties you have specified in the layout of your template.
To include the properties of a document in your report, add the following macro to the
template:
d_attribute name (For example: d_ItemTag or d_Description)
You can add plant and plant group column headers to your templates. Use the following
macros to show plant and plant group names. Note that all macro names are case sensitive:
Plant.Name
Area.Name
Unit.Name
Unit.<custom property>
You can use custom properties to add client information.
For project and contractor information, use the following:
Project.<PropertName>
Contractor.<PropertName>
399
15.
16.
17.
18.
19.
20.
The column header for Value and Short Value can be any text. For example, Long
Manufacturer or Short Manufacturer.
For the property column header that will display the Short value, type a name in the Name
Box of Microsoft Excel as shown below:
ShortValue_[property name]
For example:
ShortValue_Manufacturer
Save the report.
To activate this functionality, edit your Excel report.
In the Microsoft Excel, do one of the following:
Press Alt+F11.
Click View and then Macros > View Macros.
On the Macros dialog box, click Edit.
At the top of "ThisWorkBook" sheet code, type the following code:
Public m_objXLAgent As Object
The header is part of the tabular format report template where data is not mapped based
on rows. That is, you are free to type a label and map report item properties anywhere in
the lines that you designate for your header.
The header is a good place to put information that applies to all the items in your report,
such as Unit or Plant Name.
Also, you can add graphics in your report header.
Be sure to include space in your header for the labels of your columns.
3. Choose the number of empty lines that you want between rows in your report. Each row is
filled with properties for one item.
Some report templates, for example some Line List reports, designate two rows of data
for each report item and then an empty row.
400
5.
6.
7.
8.
When sorted in ascending or descending order, the properties that have sub-properties
appear first sorted alphabetically, followed by the properties that do not have
sub-properties, sorted alphabetically.
For a summary report, the list entry Report Item Group Total that appears at the lowest
level is always at the bottom of the list, regardless of the sort order selected.
Click OK to close the Options dialog box.
Complete general labels and graphics, if needed, in your header.
Complete column headings in the last row of your header.
Select a cell in your report template where you want to map a particular property.
This cell can be either in the body of the report or in the header.
9. Choose the property that you want to map to your cell from the Map Properties menu. The
items on this menu are chosen when you define the contents of your template. For more
information, see Define the Contents of Your Report Template.
You only have to map properties for one item. Properties for all the items follow the format
you map for the first one.
Only one property can be mapped to a given cell, although the same property can be
mapped to more than one cell.
10. Repeat the previous steps until you have mapped all the properties that you want to map on
this report template.
11. Save the template and quit Microsoft Excel.
Because the delivered report templates have a tabular format, if you create a template based
on an existing template, the format of your report template is also tabular. Select Blank as
your source template if you want to create a fixed or composite format report template.
The location of plant-level report templates is specified in Options Manager. The location for
user-level templates is defined on the Files tab of the Options dialog box (Tools > Options).
When you add any property value in the header, a new Microsoft Excel worksheet is created,
and the header is saved on the new sheet because the entire header no longer fits in the
space allotted on the first sheet. You can customize the number of rows in the report header
by using the Options command on the SmartPlant Reports toolbar and choosing a larger
value in the Rows in report header option in the Options dialog box.
401
Each item in the report has its own page. The properties of the first item are displayed on
the first worksheet, but the properties for subsequent items in the report are displayed
starting with the third sheet because the second worksheet is tabular format.
On the SmartPlant Reports toolbar, you use the Options command to designate space
for your header and to specify the number of blank lines that you want between rows of
data on your report. The Options command is not available for fixed format report
templates because you are free to place headers and data anywhere you want to on your
worksheet; however, the Options command is available for you to use in the tabular
portion of the composite report template.
2. Define the layout of the second Microsoft Excel worksheet. In a composite format report
template, the second worksheet is automatically tabular format. For more information about
defining tabular format report templates, see Define the Layout of a Tabular Format Report
Template (on page 400).
402
You can map only one property into a given cell, although you can map the same property to
more than one cell.
When you add any property value in the header, a new Microsoft Excel worksheet is created,
and the header is saved on the new sheet because the entire header no longer fits in the
space allotted on the first sheet. You can customize the number of rows in the report header
by using the Options command on the SmartPlant Reports toolbar and choosing a larger
value in the Rows in report header option.
403
SECTION 27
Property
Description
Total Plant
Total Plant
System Code
Single digit.
System Classification
System Numbering
Equipment Unit
Classification
Component Classification
Component Numbering
Equipment Unit
Code
Component Code
405
Property
Description
Numbering
Element (for
cables only)
Examples
For a switchgear or PDB, only the System Code segments are required in most cases. Thus a
suitable KKS name for a medium voltage PDB would be '1 0BBA01', where the values are
designated as follows:
Property
Value
Total Plant
System Classification
BBA
System Numbering
01
Description
(Not used)
For a motor, the KKS identification '1 0PAC01 AP001B M01' could be used, where the values are
designated as follows:
Property
Value
Total Plant
System Classification
PAC
System Numbering
01
001
Component Classification
-M
Component Numbering
01
406
Description
Pump units
Motors
When making electrical associations, KKS naming is propagated between certain items. For
a complete list of propagation rules, see Propagation of KKS Names in SmartPlant Electrical
(on page 416).
You can change the terminology of a key on a project-specific basis provided that the contents
remain unchanged. Make sure that you do not select a code that is designated as Blocked.
Blocked coding letters are reserved for future technologies and new systems engineering
configurations. They may only be allocated and released by the VGB Technical Committee
on Technical Classification Systems.
407
11. In Options Manager, on the General Settings page, under KKS mode, do one of the
following:
Select Yes to configure the KKS naming conventions using hard-coded tag
propagation. This completes the KKS mode configuration using hard-coded tag
propagation. Note that using the hard-coded tag propagation, the software does not
propagate properties of non-KKS segments.
Select No to configure the KKS naming conventions using copy rules. Selecting No
cancels the hard-coded tag propagation and you have to define your own tag propagation
by creating copy rules for each type of tag propagation in your project. Also, you need to
define a naming convention for each item type that requires KKS naming.
408
You can use the sample KKS_SAMPLE_SPELRules.rul file to see an example of rules that
copy KKS properties from a load to its metering equipment. To see the sample rules, extract
the KKS_SAMPLE_SPELRules.rul file from the KKS zip file into your SmartPlant Electrical
Reference data folder.
To preserve name uniqueness of KKS select list values (KKS key descriptors), the non-unique
value names end in suffixes denoted as their short values.
409
6. Click Next.
410
8.
9.
10.
11.
to navigate to
411
412
When propagating KKS naming, the software copies the naming from the source item
segments to the appropriate target item segments. For this reason, in the naming convention of a
target item, you should not delete segments that are likely to receive values by
propagation. Non-relevant segments in the target item are left blank. For a complete list of
propagation rules, see Propagation of KKS Names in SmartPlant Electrical (on page 416).
1. Download the SmartPlant Engineering Manager KKS upgrade files. These include the
KKS_R1_SPEL.ddt and KKS_Sample_SPELRules.rul files.
2. Place the KKS_R1_SPEL.ddt file in the Templates folder and the
KKS_Sample_SPELRules.rul file in the Reference Data folder.
3. Create a new plant for use with KKS naming.
4. Expand the tree view for your newly-created plant and right-click the Applications folder.
5. On the shortcut menu, click Associate Applications.
413
7. Click Next.
8. On the second wizard page, under Data dictionary source, click Use custom template, and
9.
10.
11.
12.
in the Template path box, type the folder path or use the ellipsis button
the KKS_R1_SPEL.ddt file.
Add roles to the plant as desired.
Start SmartPlant Electrical Options Manager.
Click Options > General Settings.
In the General Settings window, for the KKS mode option, select No.
to navigate to
Selecting No cancels the hard-coded tag propagation and you have to define your own
tag propagation by creating copy rules for each type of tag propagation in your project.
You can use the sample KKS_SAMPLE_SPELRules.rul file to see an example of rules
that copy KKS properties from a load to its metering equipment. To see the sample rules,
extract the KKS_SAMPLE_SPELRules.rul file from the KKS zip file into your SmartPlant
Electrical Reference Data folder.
For each item type where you require KKS naming, you can specify an appropriate default
value for the Component Classification property in the Project-Wide Parameters
window. Click Options > Project- Wide Parameters and select the desired plant group
and for each item type where you require KKS naming.
13. Define your own naming conventions or copy the reference naming conventions.
414
The Define Naming Conventions dialog box opens with the KKS naming conventions
already selected by default. You can delete segment properties that you do not require
or add freeform properties in addition to the KKS segments; however, note that in this
KKS mode, SmartPlant Electrical propagates properties based only on the set of
predefined copy rules.
To preserve name uniqueness of KKS select list values (KKS key descriptors), the
non-unique value names end in suffixes denoted as their short values.
An example of a KKS copy rule:
415
Inherited Components of
Target Item Name
Possible Source
Item Types
Bus
PDB
Cell
Bus
Control station
Feeder circuit
and internals
Instrument
Space heater
Incomer circuit
and internals
Transformer
component
I/O signal
Example of Source
Item Name
All loads
1 0PAC01 AP01B
E01 (heater)
Motor
1 0PAC01 AP01B
M01
Transformer (main GT
item)
For more details of how propagation works, see Examples of KKS Naming Propagation (on page
417).
416
The software performs propagation according to hard-coded rules. Name segments that are
not included in a propagation rule remain blank.
On connecting a cable side to a load or a panel, the KKS naming is propagated to the
cable. When both sides of a cable are connected, the naming comes from the first alphabetic
item. On disconnection, the cable retains the name it received by propagation until you
reconnect it.
4. Click Refresh
417
Note that the propagation does not continue to the Feeder circuit.
2. Drag the motor from the Electrical Index and drop it on the target item (feeder circuit) in the
Electrical Engineer:
418
Example 3: Associating one or more items with another one by applying a profile
1. This example shows how naming is propagated when you add control stations to the motor by
applying a profile:
419
420
The software does not automatically increment numbering properties of KKS segments.
When creating multiple items, the names of all the items, other than the first one, appear in the
interface as zeros, for example: '00000', even though KKS naming is actually applied to
them. In such cases, the user needs to rename the individual items by changing the
appropriate numbering segment, after which the software displays the item names correctly.
The software does not reset cable names when you disconnect one of the cable sides from an
associated item that originally propagated its naming to the cable.
Moving an item to a different level in the Electrical Engineer or changing item properties does
not affect the item name.
If you change the naming convention, it only affects new items. Existing items retain their
names according to the previous naming convention.
The software does not make any validations between the item type and the KKS code.
The software does not validate imported data.
Move the mouse pointer over a segment to display a Tool Tip indicating the name of the
segment.
421
These dialog boxes allow you to select suitable classification keys when defining names of items
that use KKS naming conventions. The specific classification name depends on the segment that
you selected in the Item Tag dialog box.
Find key Allows you to type a 2- or 3-character code to drill down to an item in the Select key
list.
Select key Displays the set of available keys in a 2- or 3- level hierarchy. Click
to expand
the current portion of the hierarchy further and drill down until the full key appears in the Find key
field. You can hold the mouse pointer over longer values to display a Tool Tip showing the full
name. To select the key for the name segment, double-click the key or click the OK
command. Note that the OK command is only enabled when you select the appropriate level of
the hierarchy.
422
SECTION 28
The documents published by the two applications do not contain the same properties. For
example, instrument and cabinet data includes power supply parameters such as rated
voltage, full load current, and so forth, which originate in SmartPlant
Instrumentation. However, SmartPlant Electrical only publishes PDB/Cell/Circuit
information. Similarly, SmartPlant Instrumentation publishes host data for signals that
originate in SmartPlant Electrical, but SmartPlant Electrical does not publish the host data
back to SmartPlant Instrumentation. For this reason, if, in SmartPlant Electrical, you change
data values that originated from SmartPlant Instrumentation, you should update those values
accordingly in SmartPlant Instrumentation, and vice versa.
If you publish signals in SmartPlant Electrical for circuits that feed items other than loads,
converting equipment, generators, battery banks, instruments, or cabinets, then on retrieving
the items in SmartPlant Instrumentation and running the tasks, SmartPlant Instrumentation
does not display the associated items.
Whenever you run tasks in the interface that create or update items in SmartPlant Electrical,
the software does not validate the data; however, you can select the items and perform batch
data validation (for details, see Fix Inconsistencies (on page 35)).
423
kW
Format = g3
424
Item Type
Is unique (check
box)
Cabinet
Plant
Select
Instrument
Select
SignalRun
Select
After you have defined the mapping between the source and target units (or equivalent lowest
level plant group) and you have transferred data to SmartPlant Instrumentation, you should
not change the target unit mapping definitions, because the data cannot be moved in
SmartPlant Instrumentation in certain cases (for example where no naming convention is
defined for the target unit).
You can create additional units in the SmartPlant Electrical plant group hierarchy if
needed. In this case, you must run the Publish Plant Groups command again to create
those units in SmartPlant Instrumentation and map them to the SmartPlant Electrical units.
425
The software retrieves data into the appropriate plant groups at various levels of the plant
hierarchy, regardless of the plant group that you are currently logged in to.
When you run a task that creates a new cabinet or instrument, the software changes the value
of the Override FLA calculation property to Manual to ensure that there is no inconsistency
between SmartPlant Electrical and SmartPlant Instrumentation for the values of the Full load
current property.
If you view the properties of a Create task, the destination item tag is the same as the source
item tag until you run the task. After you run the task, the destination item tag receives the
appropriate SmartPlant Electrical designation.
It is possible for SmartPlant Instrumentation users to delete items that originated from
SmartPlant Electrical, such as signals. In this case, when data is next published from
SmartPlant Instrumentation and retrieved into SmartPlant Electrical, the software creates
Delete tasks for those items on the To Do List dialog box. If you do not want those items to
be deleted from the SmartPlant Electrical database, you should click
from the To Do List dialog box.
426
427
As shown here, the SmartPlant Electrical equivalent of a reference cable is the SmartPlant
Instrumentation cable type property.
428
The software will import SmartPlant Instrumentation cables which do not have correlated
reference cables in SmartPlant Electrical (according to the cable-type). However, these cables will
not have conductors or any other cable specification since the definition of these cables is
incomplete.
Be aware that if you import cables that dont have a definite structure (that is, a number of sets and
conductors) and are not associated with a well-defined reference cable, at a later stage you will
not be able to synchronize the plant cables with the updated reference cable automatically. You
will have to do it manually, by using the Replace Cable command for each cable that you want to
synchronize or by doing it in batch mode.
429
430
SmartPlant Electrical
Instrument
Junction box
Junction box
Cabinet
Cabinet
Cabinet
Marshaling rack
Cabinet
The default plant break down system (plant - area - unit) for importing SmartPlant
Instrumentation cables and equipment is defined in the shipped links in Import Manager. The
default setting is that all the items will be imported on the highest plant hierarchy level. You can
customize this data by editing the shipped links as you require.
431
Open the SPIDomainCables.xls and define a name range for a range that starts at A1 and
includes the last cell in the PanelId2 column.
The name must be SPI_Cables.
432
SECTION 29
Note the following limitations regarding publishing and retrieving parallel connections:
It is not possible to publish to ETAP electrical items that are connected in parallel. These
items will not be published at all.
When retrieving electrical items that are connected in parallel from ETAP, the software
creates a new bus in SmartPlant Electrical and connects these items to this bus using a
non-parallel connection.
When publishing junction boxes from SmartPlant Electrical to ETAP, ETAP retrieves these
items as bus nodes. When publishing these bus nodes back to SmartPlant Electrical, the
software identifies them as junction boxes. Note that the software disregards any existing
circuits in the junction boxes and publishes them as black boxes.
Bus
Bus
Cable
Cable
Capacitor
Capacitor
Charger
Battery charger
Contractor (ContractorType =
Contractor)
Contractor
433
434
ETAP Element
Starter
Current transformer
Current transformer
Fuse
Fuse
HVCB
Induction motor
Lumped load
LVCB
Motorized valve
Motor
Overload heater
Overload relay
Power grid
OffSite power
Reactor
Recloser
Disconnect switch
Resistor
Heater
Heat trace
Lighting fixture
Socket outlet
Welding outlet
Cabinet
Instrument
Synchronous motor
Motor
SyncGenerator
Generator
Three-winding transformer
Three-winding transformer
Two-winding transformer
Two-winding transformer
Unsupported Items
A number of items are not supported by the ETAP - SmartPlant Electrical interface. Publishing
an unsupported item can have the following possible results:
Items could be skipped or ignored in the importing application. After exporting these items
back to the original application, they may be deleted or become disconnected or dissociated
from their related items.
Inability to synchronize or update data.
Unexpected behavior.
435
436
This .mdb file is located in the ETAP home directory, under the specific project library >
DataEx_SPEL.
SmartPlant Electrical converts this .mdb file to ETAPSPELMapping.xml and overwrites
the file in the location specified in Option Manager under ETAP - SmartPlant Electrical
mapping file location.
437
438
The software exports the reference cables to the cable library file that you specified in Options
Manager and appends the new cables to the list of the existing cables in that library.
If you export reference cables that already exist in the cable library, the software ignores the
cables that have identical properties. The software exports only those cables whose
properties differ from the cables that already exist.
There are certain cable properties that must be defined for the reference cables prior to
exporting them. These properties form the ETAP cable headers and they are all mandatory
for ETAP. In addition to the properties required by SmartPlant Electrical to form reference
cables, you must define other properties that form the ETAP cable headers. Any reference
cable that lacks even one of these property definitions is rejected by the software after the
export process. The following properties must be defined before starting export:
Conductor Material
Frequency
Base Temperature
Installation
Insulation Material
Insulation Voltage Rating
kV Class
Length Unit of Measure
Number of Conductors
Source Name
Ta Base Above Ground
Ta Base Under Ground
Tc Base Above Ground
Tc Base Under Ground
Unit System
RHO
If you want to use SmartPlant Electrical cables in ETAP, you have to define all the electrical
properties that are required by ETAP. We recommend that you specify a distinct "source
name" for these cables so that they do not interfere with or override ETAP original library
cables.
The software exports the reference cables to the cable library file that you specified in Options
Manager and appends the new cables to the list of the existing cables in that library.
If you export reference cables that already exist in the cable library, the software overwrites
the old cables with the newly exported cables.
There are certain cable properties that must be defined for the reference cables prior to
exporting them. These properties form the ETAP cable headers and they are all mandatory
for ETAP. In addition to the properties required by SmartPlant Electrical to form reference
cables, you must define other properties that form the ETAP cable headers. Any reference
cable that lacks even one of these property definitions is rejected by the software after the
export process. The following properties must be defined before starting export:
Conductor Material
Frequency
Base Temperature
Installation
Insulation Material
Insulation Voltage Rating
kV Class
Length Unit of Measure
Number of Conductors
Source Name
Ta Base Above Ground
Ta Base Under Ground
439
You must specify an appropriate cable specification for each ETAP library cable before
you import the cables to SmartPlant Electrical.
Make sure that before you start the import process, all the source names of the ETAP
library cables that you want to import have been added to the Source name select list in
the Data Dictionary.
4. On the Cable Specification dialog box, do one of the following:
Click the Select check box next to the cables that you want to import.
Click Select all to select all the cables in the Cable details data window.
5. Click OK to start the import process.
440
The data transfer between SmartPlant Electrical and ETAP is based on the mapping table.
Only those properties that have been mapped with the appropriate mapping direction are
propagated from SmartPlant Electrical to ETAP. For more details, see ETAP - SmartPlant
Electrical Mapped Items (on page 433).
441
If you want to publish existing SLDs and make sure that you retain all the changes made since
the last time these SLDs were published, you must open each SLD and save it prior to
publishing. If you do not do that, the software will publish the updated items with
inappropriate coordinates. As a result, ETAP will position these SLD items in inappropriate
places on ETAP drawings.
1. On the SmartPlant Electrical menu bar, click Tools > ETAP Interface > Publish All.
2. On the Publish to External Analyzing Tool dialog box, save the file as an .xml file, which will
be used by ETAP as an import source.
The retrieve process starts only if the ETAP project name specified in the selected .xml
file is the one specified in Options Manager. If the project name specified in Options
Manager is different from the one in the selected .xml file, the software rejects the retrieval
and displays a warning message.
The software checks the mapping table revision number, which is also part of the ETAP
project .xml file. If the mapping has been modified in ETAP and no new mapping has
been done, the software displays a warning. You can continue the retrieval if you want to
do so.
Once the retrieve is completed, it results in a To Do List action similar to the one used in
SmartPlant Electrical in integration. You can examine each task before committing the
whole action list to your SmartPlant Electrical database.
3. On the SmartPlant Electrical menu bar, click SmartPlant > To Do List.
4. In the To Do List window, double-click a task to check what data is going to be populated in
your database.
The following types of task can appear in the To Do List:
Create New items will be created in SmartPlant Electrical if the items are totally
new in SmartPlant Electrical. A new item in SmartPlant Electrical is an item that the
software cannot identify by its SmartPlant Electrical ID (SP_ID), ETAP IID, or
SmartPlant Electrical item tag. Note that if the retrieved item is a disconnect
equipment item, the software does not check for the item tag property.
Update Existing items will be updated if SmartPlant Electrical can identify them by
one of the properties mentioned above.
Delete Items deleted in ETAP will be deleted in SmartPlant Electrical. Note that
this type of task is only possible when performing a Full Retrieve from ETAP.
5. Select the tasks you want to run and click Run
442
SECTION 30
443
444
3.
4.
5.
6.
Click the
Alphabetic toolbar button to display the properties alphabetically; the
Allow Publish Flag property appears at the top of the list.
Assign the equipment to a circuit and set the value of the Allow Publish Flag property of the
circuit to True.
Register a report for publishing as follows:
Click Actions > Register Report.
On the Register Report Common Properties dialog box, beside Report template, click
and select IO Signals and Equipment.
445
446
After you publish the data from SmartPlant Electrical, ETAP has its own data exchange program
which enables the import and translation of the SmartPlant Electrical .xml file.
447
448
SECTION 31
You can work only in online mode that is, As-Built and projects must be connected to the
same database.
When working in a plant that is registered with SmartPlant, the software automatically
determines the project status in the database according to the SmartPlant project status.
To be able to view and edit data in As-Built, make sure that in the Options Manager, on the
General Settings page, Allow Full Access to As-Built is set to Yes.
449
Understanding Statuses
A project status shows the stage of the project life-cycle. Possible project statuses are:
Active this is the initial state of a project right after its creation.
Completed shows that all the work on the project items has been completed and that the
items are ready to be merged back into As- Built. You cannot claim items in a project whose
status has been set to Completed or Merged.
In a project, when searching for completed items in the Project Management window,
it is now possible to select the related items which have not been completed yet and change
their status to Completed.
Merged shows that all the project items have been merged back into As-Built.
Canceled shows that the project has been canceled and it can be deleted. Selecting this
project status changes the status of the items in the project from Claimed to Scoped.
The status of an item in a project determines what you can do with the item, for example, editing
the properties in the project. Possible item statuses in the project are:
Scoped shows that the item becomes available for viewing in the project and it can be
claimed.
Claimed these are the scoped items that have been copied to the project and they are
enabled for editing. There are two modes of claiming:
Exclusive these items can only be edited in the current project and cannot be claimed for
another project.
Shared these items can be claimed for another project and edited in that project.
Completed shows that the work on the item has been completed and the item is ready to
be merged back into As-Built.
Merged shows that the item has been merged back into As-Built.
The Project Management table displays the status of claimed items.
To view the status of a claimed item in a project while in As- Built, right-click an item in the list view
pane of the Electrical Index and then click Item Status in Project. This command opens the
Item Status in Projects dialog box, which shows the item status, claim mode, and project name
for each project in which the selected item is claimed.
450
Initial Status
Final Status
Comments
Scope
None, Scoped
Scoped
Scoped
Claimed
Mark as Completed
Claimed
Completed
Clear Mark as
Completed
Completed
Claimed
Mark as Reclaimed
Merged
Claimed
Release Claim
Claimed
Claimed
451
Initial Status
Final Status
Comments
Merge
Completed
Merged
In a project, when searching for completed items in the Project Management window, it is
now possible to select the related items which have not been completed yet and change their
status to Completed.
452
If you are registered with SmartPlant, click Refresh Status on the Project Status (see "Project
Status Dialog Box" on page 754) dialog box to update the SmartPlant project status display.
In SmartPlant, the Complete Project, Reactivate, and Merge Project options are not
available unless the SmartPlant project status is also active. The Cancel Project option is
not available unless the SmartPlant project status is also Canceled.
Scoping Items
Once the Plant Administrator has scoped the project, you can start specifying which items will be
available for viewing in the project. This selection is called scoping items.
You scope items by selecting the required items in As-Built. The selection can be one of the
following:
The entire plant hierarchy that was assigned in SmartPlant Engineering Manager, according
to the scoping definitions that the Plant Administrator has made.
Individual in the Electrical Engineer.
Individual items in the Electrical Index.
Several items in the Tabular Editor.
You can select loads, converting equipment, power sources, free cables, PDBs, and so
forth. Note that the software automatically scopes all the items that are associated with the
scoped items. These items are called related items. Related items are those items that have an
electrical or functional relationship to a main item. Related items may include control stations,
associated cables, circuits, and signals.
In addition to the items that are included in the scoped plant groups, you can also scope items that
belong to unscoped plant groups. However, you will not be able to claim these items or edit them
in the project.
When scoping, the software follows certain rules that govern which items become available for
viewing in the project. For details, see Rules for Scoping Items (on page 454).
Select a Project
This procedure shows you how to select a project for the current As-Built plant. Note that you
have to select a project every time you reopen the Project Management table.
1. In an As-Built plant, click Window > New > Project Management.
2. In the Project Management table, do one of the following:
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Select Project.
You have to select a project every time you reopen the Project Management table.
After closing the Project Management table, the software removes all the items from the
Project Management table.
453
Related Item
Loads, converting
equipment, power
sources
(generators, battery
banks, offsite
power)
Power distribution
boards
Notes
(from / to sides)
Control stations and their
cables
Instruments and their cables
I/O signals
Associated Circuits, their
internals and their
PDB-Bus-Cell associations
Metering equipment
None
Drums
Cableways
Instruments
454
Related Item
Local panels,
junction boxes,
cabinets
Notes
To scope space heaters and auxiliary contacts, see Guidelines for Scoping Space Heaters
and Auxiliary Contacts (on page 455).
When scoping an item that is connected in parallel with another equipment item, the software
automatically scopes all the items that are connected in parallel to the scoped item. For
example, if you select Motor-1 that has been connected in parallel with Motor-2 and Motor-3,
the software will also automatically scope Motor-2 and Motor-3 together with their upstream
items all the way to their power sources.
You can scope the same item for more than one project.
Project Requirement
A motor connected to a Design the space heater and Scope the motor branch and the PDB
standard feeder circuit its complete power source
with its circuit so that it can be
and add the required
claimed in the project.
disconnect equipment
Add a space heater, auxiliary When merging, select both the motor,
contacts, the power supply
its new circuits, and the space heater
circuits, and the
circuitry
interconnecting cables.
A motor with a space Delete all or part of the space
heater connected to
heater circuitry.
the auxiliary contact of
the motor circuitry and
the feeder to the
auxiliary contacts
circuitry
455
You have to add items every time you reopen the Project Management table.
You cannot add items to a project that has been set to Completed.
Scope Items
Once the Plant Administrator has scoped your project, you can start scoping the items that will be
available for viewing in the project.
1. In SmartPlant Electrical, click File > Open > Plant Group to open an As-Built plant.
2. On the Open Plant Group dialog box, click Select Plant.
3. On the Open Plant Group dialog box, select the appropriate plant hierarchy level and click
OK.
4. Click Window > New > Project Management.
5. In the Project Management table in As-Built, click
.
6. On the Select Project dialog box, select the project you require and click OK.
7. With the Project Management table in As-Built open, select the main items for scoping and
then do one of the following:
Drag the selected item to the Project Management table. Note that you can only drag
single items. For multiple items wherever possible, use the Add command.
Click
Note that you can use the buffer to make a preliminary selection of items that you may
want to add to the Project Management tables. For details, see Use the Buffer to Scope
Items (on page 457).
8. Select the check box beside each main item that you want to scope.
456
Click
on the on the Project Management toolbar.
Right-click in the Project Management table and then click Paste from Buffer.
Claiming Items
You claim items by opening the project to which they were scoped, and then you select individual
items to claim. Once you have claimed an item, it becomes available for editing in the project.
You can claim main or related items separately. When claiming an item in a project, with the
appropriate Options Manager setting, you can choose claim mode Shared or Exclusive.
You cannot claim items in a project whose status has been set to Completed or Merged.
You do not need to claim new items that you create in the project.
457
Select multiple items the Electrical Index, or the Tabular Editor and click
.
.
You cannot add items to a project that has been set to Completed.
After closing the Project Management table, the software clears the all the items from the
table.
You have to add items every time you reopen the Project Management table.
Claim Items
You claim items by opening the project to which they were scoped, and then you select individual
items to claim. Note that you can claim main or related items separately. When claiming an item
in a project, with the appropriate Options Manager setting, you can choose claim mode Shared or
Exclusive.
1. In a project, click Window > New > Project Management.
2. Add the items that you require. For details, see Add Items to the Project Management Table
in a Project (on page 458).
3. Select the check box beside each item that you want to claim. For details of item statuses in
the project that determine which items you can mark for claiming, see Rules for Changing
Statuses (on page 451).
4. For each item that you want to claim, select Shared or Exclusive as the claim mode. Note
that if, in the Options Manager, General Settings, the As-Built Claim Mode option is set to
Exclusive, the Shared claim mode is not available.
5. Click the Apply command to claim the items.
458
The items are now available for editing in the project. When you have finished editing items,
you can change their status to Completed. Items with status Completed are ready for
merging into As-Built.
Check the data under Result Status to make sure that there are no problems.
You cannot claim items in a project whose status has been set to Completed or Merged.
Click
on the Project Management toolbar and then select Exclusive, Shared, or
Release Claim.
Right-click in the Project Management table and then on the shortcut menu, point to Set
Claim Mode and then click Exclusive, Shared, or Release Claim.
5. Click the Apply command to claim the items.
The Shared claim mode is only available after selecting the appropriate setting in the
Options Manager.
Release Claim
Releasing the claim of an item enables you to cancel the claim of an item. This action makes it
possible to re-scope the item in As-Built if you need to update the data in the project. After the
item has been re-scoped, you can claim it again in the project and then edit the updated
data. Note that when releasing the claim of an item, it status in the project remains
Claimed. However, the claim mode changes to Release Claim. Items whose claim mode is
Release Claim behave exactly in the same way as the scoped items as the software re-scopes
these items.
1. In a project, click Window > New > Project Management.
2. Right-click in the Project Management table and then click Show Claimed Items
3. Select the check box beside each item for which you want to release the claim.
4. Do one of the following:
Click
on the Project Management toolbar.
Right-click in the Project Management table and then on the shortcut menu, click
Release Claim.
459
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Apply.
After setting the claim mode to Release Claim, the status of the items still remains behave
exactly in the same way as the scoped items as the software re-scopes them.
To claim the items whose claim mode to Release Claim, right-click in the Project
Management table and then on the shortcut menu, click Mark as Reclaimed.
Click
on the Project Management toolbar.
Right-click in the Project Management table and then on the shortcut menu, click Mark
as Completed.
5. Click the Apply command to claim the items.
The items that have been marked as completed are no longer available for editing in the
project and are ready for merging into As- Built.
Click
on the Project Management toolbar.
Right-click in the Project Management table and then on the shortcut menu, click Clear
Mark as Completed.
5. Click the Apply command to claim the items.
The items whose status is Clear Mark as Completed become available for editing in the
project.
460
Complete a Project
Prior to merging all the project items into As-Built, you have to change the status of all the project
items to Completed. Setting the project status to Completed automatically changes the status of
all the project items to Completed and allows you to run a full merge of the current project into
As-Built. For details about running a full merge, see Merge All the Project Items into As-Built (Full
Merge) (see "Merge All Project Items into As-Built (Full Merge)" on page 464).
1. In a project, click Window > New > Project Management.
2. On the Project Management toolbar, click
.
3. On the Project Status dialog box, click Complete Project.
4. Click Close.
You cannot claim items in a project whose status has been set to Completed or Merged.
A project can only be returned to an Active state from the Completed or Merged state. If a
project has been set to Canceled, it cannot be changed back to Active. Canceled is
permanent state.
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Release from Merge.
5. Do one of the following:
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Apply.
After releasing from merge, the status of the items in the project becomes Scoped, that is,
the items will be scoped after you click Apply again.
461
You can merge all the project items into As-Built or only some of the completed items that you
select.
If you add a new item in the project, after merging the item, the software creates it in As-Built.
If you modify data for an item in the project, after merging, the software overwrites the existing
data for that item in As-Built.
If you delete an item in the project, after merging the item, the software deletes it in As-Built.
When merging an item that is connected in parallel with another equipment item, the software
automatically merges all the items that are connected in parallel to the scoped item. For
example, if you select Motor-1 that has been connected in parallel with Motor-2 and Motor-3,
the software will also automatically merge Motor-2 and Motor-3 and their upstream items all
the way to their power sources.
You can claim an item in a project and subsequently modify its data in As-Built. If you then
want to transfer the item changes from As-Built to the project, you must update the item
manually in the project. To assist you in doing this, it is recommended that you run a
comparison report first. You can also run the Release Claim command in the project to
automatically re-scope the item with the updated data from As-Built, but in this case any
changes you have made to the item in the project will be lost.
You can only edit data in As-Built if in Options Manager, General Settings, the Allow Editing
in As-Built property is set to Yes.
For the rules that govern document revisions, see Rules Governing Revisions for Documents
Merged Back into As-Built (on page 463).
462
For the rules that govern document revisions when merging documents into As-Built, see
Rules Governing Revisions for Documents Merged Back into As-Built (on page 463).
In SLDs and schematics, the software displays clouds around the items that differ from the
current data. The last revision number is shown in a triangle beside the cloud.
The software uses index numbers to identify the changes in associations between electrical
items.
The software generates a tabular report where it shows all the changes and shows the
changes in associations using index numbers as they appear in the drawing.
For registered reports, the software opens two Excel files. One of the Excel files displays
changed data with blue shading. The second file is a summary of all changes and it is called
Registered Comparison Report. This report displays the previous and current data for
each tag that has undergone a change. Note that you can compare a registered report only if
it is a simple tabular report.
In SLDs, the software indicates the following changes:
All added and deleted electrical items except for control stations.
Added, deleted, and updated properties of electrical items.
Changes in associations.
Attachment to a different document template.
In schematic drawings, the software indicates the following changes:
Added, deleted, and updated properties of electrical items.
463
464
The software merges all the completed items into As-Built, including the child items.
The status of all the child items in the project must be Completed. If the status of some of the
child items is not set to Completed, full merge is not possible.
Once a project has been merged, the software sets the status of the project and the status of
all the items in the project to Merged. No further activities are possible in this project as all the
items in the project are locked and cannot be edited. If you want to edit some of the items in a
merged project, you must first reactivate the project. After reactivating a project, all the items in
that project become scoped and you will have to claim the items that you want to edit.
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Merge.
If you select an item that has child items whose status is not set to Completed, the main item
cannot be merged.
When merging an item that is connected in parallel with another equipment item, the software
automatically merges all the items that are connected in parallel to the scoped item. For
example, if you select Motor-1 that has been connected in parallel with Motor-2 and Motor-3,
the software will also automatically merge Motor-2 and Motor-3 and their upstream items all
the way to their power sources.
Miscellaneous Options
The following additional options are available:
Filter the Project Management Table Display (on page 466)
Select a Display Option (Jump Template) (see "Select a Display Option" on page 466)
Generate an Excel Report (Jump Template) (see "Generate an Excel Report" on page 467)
Backup a Project
Restore a Project
465
Command
Explanation
Show Items Deleted from Filters the display to show only those items that
As-Built
have been deleted in As-Built.
Show Item Properties
466
Click
on the Project Management toolbar and then select the required option.
Right-click in the Project Management table, click Display, and then click a command:
Main Items Only, Main Items with Related Items, All Items as List.
Click
on the Project Management toolbar.
Right-click in the Project Management table and then click Excel Report.
467
SECTION 32
The actual path that you type will depend upon the location where you installed the software.
Publish, Retrieve and other SmartPlant menu items are only available in the As-Built, not in
the projects.
You must first claim items in projects in order to modify them. The As-Built does not claim
items to edit them.
As-Built editing will be enabled according to As-Built access rights.
469
Description
Examples
Plant items
Reference schema
items
Reference data
(metadata)
Information Handling
The following table summarizes how the software handles these different types of information at
various stages of the workflow.
Workflow Stage
Information Type
Data rescoping
470
Method of Handling
User specifies which data to scope in SmartPlant
Electrical. User creates package in SmartPlant
Engineering Manager for transferring the data to the
off-site plant.
Reference schema
items
Reference data
(metadata)
Plant items
Reference schema
items
Reference data
(metadata)
Information Type
Method of Handling
Transfer of data
back to host
Plant items
Reference schema
items
Reference data
(metadata)
When saving a project for reloading into a plant or saving a plant for merging in the host,
SmartPlant Engineering Manager copies to the host or off-site plant all new reference schema
items of the following types only:
Reference cables
Typical blocks
Typical schematics
Cableway components
Existing reference schema items and other types of reference schema items remain unchanged.
471
472
In the off-site plant, the software creates a schema known as the reconciliation area.
The data in the reconciliation area is identical to that of the project that you exported.
On the page where SmartPlant Electrical is shown as the application to associate, if,
under the section Select the schema data for copying, you select the Project check
box, the software also creates an off-site project that initially contains data identical to that
of both the source project and the reconciliation area.
5. Edit data in the off-site project as needed.
Do not change the names of units in the off-site plant where you transfer data,
otherwise the software will not be able to merge the data back to the host later.
During editing in the off-site plant, it is possible to continue to make changes in the host
As-Built. To synchronize those changes with the off-site plant, you must rescope the
host data (for details, see below).
If, after exporting the project as a package, you create new metadata in the host As-Built
that affects the plant data, you must run the SmartPlant Reference Data Synchronization
(RDS) Manager to create a separate RDS package. You must synchronize metadata
with the host using this RDS package before importing the package containing the plant
items. For details of how to create the RDS package and how to synchronize the
metadata, refer to the SmartPlant Reference Data Synchronization Manager User's
Guide.
The software copies all new reference cables, typical blocks, and cableway components
to the host. Changes in existing reference cables, typical blocks, and cableway
components do not propagate back automatically to the host at this stage, but will do so
when you rescope data from the host.
In the host, the software updates the project only. As-Built data remains unaffected.
5. Merge the project into the As-Built in the host.
If desired, you can perform a partial merge.
473
The software copies all new reference cables, typical blocks, and cableway components
to the off-site plant. Existing reference cables, typical blocks, and cableway components
remain in the off-site plant unchanged.
In the off-site plant, the software updates data in the reconciliation area only. Data in the
project remains unaffected.
5. In the off-site plant, scope or claim items as desired into the project.
This step should be performed with care to ensure that you do not inadvertently
overwrite any of the data that you changed in both the off-site project and the host As-Built.
474
3. Open the project and select the plant group where your data resides.
475
8. On the Save Project as Offsite dialog box, accept the default location for exporting the plant
to, or change the location by clicking the ellipsis button
476
12. On the following page of the Load Offsite Plant Structure Wizard, beside Zip file of plant,
click the ellipsis button
477
13. Browse to the zip file containing the package from the host that you want to load.
478
15. In the Name field, type the name of the new plant to be created in the off-site plant.
479
17. Specify the plant structure path (in this example, the plant structure path was copied from the
folder path one level above the backup location).
480
19. Accept the database server and user connection information. If desired, specify a different
path for the SmartPlant Electrical reference data.
481
482
3.
4.
5.
6.
483
If you made revisions in the plant and you want to include those revisions in the
package, select Include SmartPlant Electrical revisions.
8. Click OK to export the off-site plant data as a package. The status bar at the bottom of the
dialog box shows the current activity.
484
10. On the following page of the Load Standalone Project Wizard, beside Zip file of plant, click
the ellipsis button
485
12. Click Next. The page shows you details of the package.
486
14. Open SmartPlant Electrical and merge the updated project data back to the As-Built.
487
5. On the Save Project for Reload dialog box, accept the default location for exporting the plant
to, or change the location by clicking the ellipsis button
488
489
490
11. Click Finish to load the package into the off-site plant.
491
The software loads the package into the reconciliation area only; data in the off-site
project is unaffected.
Data loaded into the reconciliation area from a rescoped package does not have any
status assigned.
We recommend that you use the same Data Dictionary template for the greenfield plant
as the template that was used to create the host plant. If the plants were created using
different Data Dictionary templates, you must run SmartPlant Reference Data
Synchronization (RDS) Manager to create a separate RDS package. You must
synchronize metadata with the host using this RDS package before importing the
package containing the greenfield plant items. For details of how to create an RDS
package and how to synchronize metadata, refer to the SmartPlant Reference Data
Synchronization Manager User's Guide.
When running the Associate Applications command for the greenfield plant, the plant
can be associated with SmartPlant Electrical only and must not be associated with any
other applications.
2. Create the desired items in the greenfield plant.
Ensure that all the data in the greenfield plant is correct before saving the plant
as a package. This is important because later on, you will be able to load the package into the
target plant as a project only once.
3. Save the plant as a package using the Save Plant Structure command. For details, see Save
a Plant Structure (on page 493).
4. To synchronize reference schema items (reference cables, cableway components, typical
blocks, typical schematics, lookup tables, and so forth) between the plants, in SmartPlant
Electrical Options Manager, do the following:
a. Connect to the greenfield plant and create a reference data package. For details, see
Create a Reference Data Package (on page 493).
b. Connect to the host plant and update the reference data from the package you created in
the greenfield plant. For details, see Update Reference Data from a Package (on page
494).
These actions synchronize the items created in the SmartPlant Electrical Reference
Data Explorer of the greenfield plant by updating them in the SmartPlant Electrical
Reference Data Explorer of the host plant.
5. In SmartPlant Engineering Manager, right-click the desired host plant (target) and on the
shortcut menu, click Enable Projects.
6. Import the package into the host plant as a project using the Load Plant as Project
command. For details, see Load a Plant as a Project (on page 495).
The Load Plant as Project command is enabled only if the plant is associated with
SmartPlant Electrical alone and not with any other application and only after the Enable
Projects command has been run for the plant.
492
If a reference item has been used in the current plant, the software marks this reference item
as mandatory and it is recommended that you include it in the package. The following
reference items are considered mandatory if they are used the current plant:
All types of cables
Glands
Cableway components
Profiles
Typical circuits
Typical schematics
I/O sets
Lookup tables
493
Click Save Session to save your selections if you want to pause the current session. Click
Open Session to resume your selections. You can open a saved session from a package or
session file.
Click Open Session to open a saved session. On the Open dialog box, from the Files of type
list, select one of the following:
Reference Data Selection Session (xml) to open a saved selections session.
Reference Data Package (zip) to open a session from an existing package.
Click Report to generate an Excel file that will contain all the selections that you have made.
Once the software finishes creating the package, a message is displayed informing you
whether or not the package has been created successfully. Click the Log button to open the
package creation log file to see if there are any reference items that failed to be included in the
package.
In the Items grid, child items that were included with their parent items are not shown by
the software. For example, if the package contains a reference motor with a space heater,
both items are included in the package without displaying the space heater in the grid.
It is not possible to select existing items to be included in the update. In this version of the
software, only new items can be included in the update process.
Make sure that you click Save Selections after making a change in the selection. This
way the package will retain all the selections.
4. Click the Report button to generate an Excel file that shows all the items that you have
selected from the current package.
5. Click the Update Data button to start the update process.
494
If a reference item has been used in the current plant, the software marks this reference item
as mandatory and it is recommended that you include it in the package. The following
reference items are considered mandatory if they are used the current plant:
All types of cables
Glands
Cableway components
Profiles
Typical circuits
Typical schematics
I/O sets
Lookup tables
Click Save Selections to save your selections if you want to pause the current session. The
software saves your selections in the current package. Click Open Package and navigate to
the package file to resume your selections.
Once the software finishes the update process, a message is displayed informing you whether
or not the update has been completed successfully. Click the Log button to open the update
log file to see if there are any package items that failed to be included in the update.
495
496
SECTION 33
In This Section
Save Project as Offsite Command (File Menu) ............................. 497
Save Project as Offsite Dialog Box ................................................ 498
Save Project for Reload Command (File Menu) ............................ 499
Save Project for Reload Dialog Box .............................................. 499
Save Plant for Merge in Host Command (File Menu) .................... 500
Save Plant for Merge in Host Dialog Box ...................................... 500
Load Offsite Plant Structure Command (File Menu) ..................... 501
Load Offsite Plant Structure Wizard .............................................. 501
Load Plant as Project Command (File Menu) ................................ 512
Load Plant as Project Dialog Box .................................................. 513
Load Standalone Project Command (File Menu) .......................... 514
Load Standalone Project Wizard ................................................... 514
497
Include applications
Select the application that you want to include in the off-site project. The available options are:
SmartPlant P&ID
SmartPlant Electrical
SmartPlant Instrumentation
498
Include applications
Select the application that you want to include in the saved project. The available options are:
SmartPlant P&ID
SmartPlant Electrical
SmartPlant Instrumentation
499
Include applications
Select the application that you want to include in the plant. The available options are:
SmartPlant P&ID
SmartPlant Electrical
SmartPlant Instrumentation
500
Zip file of plant Specify the path to the location of the plant structure you want to load.
501
Plant group type Displays the plant group type of the root item.
Name Displays the name of the copied plant structure. You must change this name if you are
copying the plant structure to the same site. This name is limited to 80 characters and cannot
contain any of the following characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
Description Type a description for the plant (optional). The description is limited to 240
characters.
Address Type an address identification for the plant. This option appears only if the plant
structure uses Hierarchy 2: Site/Plant/Unit or uses a hierarchy with the Site plant group type as the
root item.
502
Applications to associate Select the application that you want to associate with the plant
structure, the options are: SmartPlant P&ID, SmartPlant Electrical, and SmartPlant
Instrumentation.
If you want to associate SmartPlant Instrumentation, you must first configure the
SmartPlant Instrumentation database for the site server. For details, see Configuring a
SmartPlant Instrumentation Database.
503
The paths for the plant structure and backup location must use the Universal Naming
Convention (UNC) format and cannot exceed 255 characters.
An asterisk (*) at the end of an item name indicates a value is required for that item.
Plant structure path Specify the path to the storage location for the plant data and the drawing
files. You must create the plant structure share before running this wizard, using the form
\\siteserver\sitename\plantname. The wizard will create the 'plantname' folder if it does not
already exist.
Backup location Specify the path to the shared storage folder for backing up the plant files.
Seed location Specify the location of your plant templates, the default seed location is the
SmartPlant Engineering Manager home folder.
Save seed location as the preferred setting Select to make the current seed location your
default setting.
504
Select a backup location outside the Plant structure path to avoid recursive backups being
stored in a single backup file. For example, if the Plant structure path is
\\siteserver\sitename\plantname, do not set the backup location for plantname to
\\siteserver\sitename\plantname\backups.
Be sure the backup location has plenty of available space because the restore process
generates a temporary folder in this backup location while the plant data is being
restored. This folder is removed when the process finishes.
Database type Displays the database type used by the site in which the plant will be created.
Oracle alias Type the name of the Oracle Net Service name as defined by your database
administrator. This option appears only if Oracle is selected as the database type.
Database node Type the Node Name of the server on which the SQL Server database
resides. This option appears only if SQL Server is selected as the database type. This node
name cannot contain any spaces.
System user Type a database system user name. This name does not have to be the
database administrator user name, but this user must have sysadmin privileges (for SQL Server)
or the DBA role (for Oracle).
System password Type the system password.
Oracle system passwords cannot contain any special characters other than: @ ('at' symbol), .
(period), and _ (underscore). SQL Server database passwords cannot contain the character: '
On an Oracle 10g platform using different instances, when exiting this Wizard page, you may
receive a message about having insufficient privileges to create the plant structure, followed by a
list of the required privileges. To fix this problem, you must create one or more of these privileges
manually using Oracle tools.
505
We recommend that you do not use SYSTEM for the default tablespace because Oracle uses
this tablespace for its own use.
If you create new Oracle tablespaces or SQL Server databases after starting this wizard, you
must refresh the tablespace list by clicking Back and then clicking Next to return to this page
before the new information will display in the appropriate lists.
Database username Type the user name you want to use for the plant schema user. This
value, which must be unique in the database, defaults to the plant name that you specified
earlier. For more information about default database user names, see Understanding Default
Database User Names.
Database password Type the password for the plant schema user. We recommend using the
database user name specified above as this password.
Confirm password Re-type the password for the plant schema user.
506
The software sets the related password defaults for the above user name automatically to
<default user name> for Oracle and to <default user name> + '1' for SQL Server. In the case
of SQL Server 2005 running on Windows Server 2003, if you are using SQL Server
authentication, you can specify that SQL Server 2005 is to use the password validation rules
that are used by Windows Server 2003.
Database usernames cannot start with a numeric digit and cannot contain any of the following
characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
Oracle database user names are limited to 30 characters. Because plant names can be up to
64 characters long, the software uses only the first 12 characters of the name in creating the
default database user names.
Oracle database passwords cannot contain the characters: " ' @
SQL Server database passwords cannot contain the character: '
We recommend that you do not use SYSTEM for the default tablespace because Oracle uses
this tablespace for its own use.
If you create new Oracle tablespaces or SQL Server databases after starting this wizard, you
must refresh the tablespace list by clicking Back and then clicking Next to return to this page
before the new information will display in the appropriate lists.
Database username Type the user name you want to use for the plant data dictionary
user. This value, which must be unique in the database, defaults to the plant name that you
specified earlier, with the letter "d" appended. For more information about default database user
names, see Understanding Default Database User Names.
Database password Type the password for the plant data dictionary user. We recommend
using the database user name specified above as this password.
Confirm password Re-type the password for the plant data dictionary user.
The software sets the related password defaults for the above user name automatically to
<default user name> for Oracle and to <default user name> + '1' for SQL Server. In the case
of SQL Server 2005 running on Windows Server 2003, if you are using SQL Server
authentication, you can specify that SQL Server 2005 is to use the password validation rules
that are used by Windows Server 2003.
Database usernames cannot start with a numeric digit and cannot contain any of the following
characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
Oracle database user names are limited to 30 characters. Because plant names can be up to
64 characters long, the software uses only the first 12 characters of the name in creating the
default database user names.
Oracle database passwords cannot contain the characters: " ' @
SQL Server database passwords cannot contain the character: '
507
This screen is only displayed if an application was associated to the plant structure selected
previously in the Applications to associate page of the wizard.
An asterisk (*) at the end of an item name indicates a value is required for that item.
Oracle service/alias Displays the Oracle Net Service alias specified previously in which the
plant will be created. This option appears only if Oracle is selected as the database type.
Database node Displays the Node Name of the server on which the SQL Server database
resides. This option appears only if SQL Server is selected as the database type.
Database name Displays the name of the SQL Server database in which the plant will be
created. This option appears only if SQL Server is selected as the database type.
Oracle tablespace Select the default Oracle tablespace name for your plant database. These
tablespaces were defined when the database administrator created the default database instance
using Oracle Database Assistant. This option appears only if Oracle is selected as the database
type.
508
We recommend that you do not use SYSTEM for the default tablespace because Oracle uses
this tablespace for its own uses.
If you create new Oracle tablespaces or SQL Server databases after starting this wizard, you
must refresh the tablespace list by clicking Back and then clicking Next to return to this page
before the new information will display in the appropriate lists.
Oracle temp tablespace Select the default Oracle temporary tablespace name for your plant
database. If this list is empty, contact your database administrator. This option appears only if
Oracle is selected as the database type on the previous page.
Database username Type the user name you want to use for the SmartPlant Electrical
schema user. This value, which must be unique in the database, defaults to the plant name that
you specified earlier, with the letters "el" appended. For more information about default database
user names, see Understanding Default Database User Names.
Database password Displays the default database password, as set by the database
software. You can change the password for the SmartPlant Electrical database user by typing a
new password in the Database password field. We recommend using the default SmartPlant
Electrical user name defined above as this password.
Confirm password Re-type the password for the database user.
SmartPlant Electrical reference data path Taken from the Plant Structure Path as set
previously in the Target Paths screen of the wizard. To select a different path, type the required
path or click the ellipsis button
to browse to the reference data path for the application
options. This field is limited to 255 characters.
The software sets the related password defaults for the above user name automatically to
<default user name> for Oracle and to <default user name> + '1' for SQL Server. In the case
of SQL Server 2005 running on Windows Server 2003, if you are using SQL Server
authentication, you can specify that SQL Server 2005 is to use the password validation rules
that are used by Windows Server 2003.
Database usernames cannot start with a numeric digit and cannot contain any of the following
characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
Oracle database user names are limited to 30 characters. Because plant names can be up to
64 characters long, the software uses only the first 12 characters of the name in creating the
default database user names.
Oracle database passwords cannot contain the characters: " ' @
SQL Server database passwords cannot contain the character: '
This screen is only displayed if SmartPlant Electrical was associated to the plant structure
selected previously in the Applications to associate page of the wizard.
An asterisk (*) at the end of an item name indicates a value is required for that item.
Application to associate Displays the application being associated. This value is carried
forward from the previous page.
509
We recommend that you do not use SYSTEM for the default tablespace because Oracle uses
this tablespace for its own uses.
If you create new Oracle tablespaces or SQL Server databases after starting this wizard, you
must refresh the tablespace list by clicking Back and then clicking Next to return to this page
before the new information will display in the appropriate lists.
Oracle temp tablespace Select the default Oracle temporary tablespace name for your plant
database. If this list is empty, contact your database administrator. This option appears only if
Oracle is selected as the database type on the previous page.
Database username Type the user name you want to use for the SmartPlant Electrical
reference schema user. This value, which must be unique in the database, defaults to the plant
name that you specified earlier, with the letters 'elref' appended. For more information about
default database user names, see Understanding Default Database User Names.
Database password Displays the default database password, as set by the database
software. You can change the password for the SmartPlant Electrical database user by typing a
new password in the Database password field. We recommend using the default SmartPlant
Electrical user name defined above as this password.
Confirm password Re-type the password for the database user.
510
The software sets the related password defaults for the above user name automatically to
<default user name> for Oracle and to <default user name> + '1' for SQL Server. In the case
of SQL Server 2005 running on Windows Server 2003, if you are using SQL Server
authentication, you can specify that SQL Server 2005 is to use the password validation rules
that are used by Windows Server 2003.
Database usernames cannot start with a numeric digit and cannot contain any of the following
characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
Oracle database user names are limited to 30 characters. Because plant names can be up to
64 characters long, the software uses only the first 12 characters of the name in creating the
default database user names.
Oracle database passwords cannot contain the characters: " ' @
SQL Server database passwords cannot contain the character: '
We recommend that you do not use SYSTEM for the default tablespace because Oracle uses
this tablespace for its own use.
If you create new Oracle tablespaces or SQL Server databases after starting this wizard, you
must refresh the tablespace list by clicking Back and then clicking Next to return to this page
before the new information will display in the appropriate lists.
Database username Type the user name you want to use for the application data dictionary
user. This value, which must be unique in the database, defaults to the plant name that you
specified earlier, with the letters 'eld' appended. For more information about default database
user names, see Understanding Default Database User Names.
Database password Type the password for the application data dictionary user. We
recommend using the application data dictionary user name defined in the field above as this
password.
Confirm password Re-type the password for the database user.
The software sets the related password defaults for the above user name automatically to
<default user name> for Oracle and to <default user name> + '1' for SQL Server. In the case
of SQL Server 2005 running on Windows Server 2003, if you are using SQL Server
authentication, you can specify that SQL Server 2005 is to use the password validation rules
that are used by Windows Server 2003.
Database usernames cannot start with a numeric digit and cannot contain any of the following
characters: ~ ` ! % ^ & * ( ) - + = { } [ ] \ / ; : " < > , . ? |
511
Oracle database user names are limited to 30 characters. Because plant names can be up to
64 characters long, the software uses only the first 12 characters of the name in creating the
default database user names.
Oracle database passwords cannot contain the characters: " ' @
SQL Server database passwords cannot contain the character: '
512
Zip file of plant Specify the path to the location of the plant structure you want to load.
Project name The name of the new project, which comes from the name of the selected
source plant.
Project description If a description of the selected source plant exists, it appears in this field
as the description of the new project.
Mapping
Allows you to map the target plant groups in your current plant to the source that is used as the
basis of the new project.
513
514
Zip file of plant Specify the path to the location of the plant structure you want to load.
515
516
SECTION 34
SmartPlant Electrical interacts with SmartPlant Foundation by correlating items between the plant
database and the SmartPlant Foundation database, retrieving documents such as Electrical
Power Elements, Electrical Signal List, Cable Schedule reports, and P&IDs, from SmartPlant
Foundation. Also, SmartPlant Electrical creates a set of tasks in the To Do List that you can run
to update the plant database. In SmartPlant Electrical, you can also use the commands on the
SmartPlant menu to publish documents and retrieve data, access the SmartPlant Foundation
517
Registering Tools
Before you can publish and retrieve documents from any of the other authoring tools, such as
SmartPlant P&ID or SmartPlant Instrumentation, you must register each plant in SmartPlant
Electrical with a SmartPlant Foundation database. The connection allows SmartPlant Electrical
to use the commands on the SmartPlant menu. A SmartPlant Engineering Manager
administrator typically registers a plant.
The software maps a plant and all its projects to a single SmartPlant Foundation URL, which
points to one, and only one, SmartPlant Foundation plant database and its projects. When you
use the Register command in any of the authoring tools, you are registering an authoring tool
plant with a SmartPlant Foundation URL and plant that you specify.
The system administrator must register each plant in the authoring tool once; this action takes
place in SmartPlant Engineering Manager. After the plant is registered, you can publish and
retrieve documents.
See Also
Access the SmartPlant Foundation Web Client (on page 520)
Schema Mapping (on page 521)
Publishing (see "Publishing Documents" on page 543)
518
SmartPlant Electrical ships a sample report named Reference Data Cables Interface to
SmartPlant 3D, that you can use as a source to be transferred to SmartPlant 3D, so that
SmartPlant 3D users can create their Catalog using the report data.
If cables that originated in SmartPlant Electrical were subsequently deleted in SmartPlant 3D
and then published back from SmartPlant 3D, SmartPlant Electrical does not generate Delete
tasks for those cables.
Make sure that the following select lists in SmartPlant Electrical must match the content of the
related select lists in SmartPlant 3D:
Routing status
Segregation level
SmartPlant Electrical also publishes to SmartPlant 3D the relations to the cable side 1 and side
2. If SmartPlant 3D does not contain the relations, SmartPlant 3D cannot perform cable routing.
This means that:
In SmartPlant Electrical, the cables must have their side 1 and side 2 associated before
publishing.
In SmartPlant 3D, users must make sure that each object referenced in the cable sides has a
corresponding object in the SmartPlant 3D data model.
519
See Also
Publishing (see "Publishing Documents" on page 543)
This command is available only if the active plant has been registered. For more information,
see SmartPlant Engineering Manager Help.
From the SmartPlant Foundation Web Client, you can perform a number of tasks, such as
publishing or retrieving documents, comparing documents, subscribing to document changes,
and so forth. Many of these tasks can be performed from the authoring tools, such as
SmartPlant Instrumentation or SmartPlant P&ID, but the Web Client provides unique access
to other features such as the Web Client To Do List and search capabilities.
520
Schema Mapping
This section describes the assumptions, rules, and limitations imposed by the SmartPlant
Electrical adapter on schema mapping.
This section describes the structure of the tool schema and how it is used by the authoring tool
SmartPlant integration adapter in support of the publish and retrieve operations. This topic does
not provide a list of the classes, properties, or enumerated lists (select lists) that are mapped by
the delivered SmartPlant Electrical tool schema. You can obtain this information by viewing the
tool schema directly. This set of topics does not describe the user interface of the Schema Editor.
Before modifying the mapping for SmartPlant Electrical, you must understand:
The SmartPlant Electrical software
The SmartPlant Electrical data model
The delivered mapping for SmartPlant Electrical
How the delivered mapping for SmartPlant Electrical works
SmartPlant schema modeling
The Schema Editor
The To Do List feature of SmartPlant Electrical
In the topics that describe schema mapping, the following terms are frequently referenced:
Tool schema Defines the SmartPlant Electrical objects to be published or retrieved and how
they map to objects in the SmartPlant schema. The tool schema implements mapping
between the objects in the SmartPlant Electrical data model and the objects in the SmartPlant
schema. Users who customize either the SmartPlant Electrical data model or the SmartPlant
schema may also need to customize the mapping contained in the tool schema.
SmartPlant schema Defines the SmartPlant integration data model.
Adapter The SmartPlant Electrical code module that supports the SmartPlant integration
commands.
When you publish SmartPlant Electrical data, the SmartPlant integration adapter extracts data
from the SmartPlant Electrical database and converts it into a set of objects and relationships that
are compatible with the SmartPlant schema. These objects and relationships are defined in an
.xml file, which is sent to SmartPlant Foundation for further processing. For SmartPlant Electrical,
the name of this file is SPELMap.xml, and it is located in the SmartPlant Electrical home folder.
521
Mapping Configuration
The SmartPlant Electrical adapter uses the tool schema map file and the Schema Editor,
delivered with the SmartPlant Schema Component, to perform mapping between the SmartPlant
Electrical object structure and the structure of objects in the SmartPlant schema. The map file is
installed with SmartPlant Electrical Setup. This file includes all objects that are mapped for
SmartPlant (not all objects that exist in SmartPlant Electrical, not all properties, only those that can
be of any relevance for other applications that use SmartPlant ). In accordance with the
SmartPlant Electrical data model, the Schema Editor knows what SmartPlant Electrical object to
put a property on.
522
MapClass
The MapClass object corresponds to the IMapClassDef interface in the Tool Schema Data Model
diagram. In general, there is a MapClass object in the tool schema for each SmartPlant Electrical
class (ItemType) that needs to be published or retrieved. MapClass is referred to as
SPMapClassDef in the Schema Editor user interface. The properties and relationships for a
MapClass object can be viewed in the Edit Map Class Definition dialog box.
General
Property
Description
UID
Name
523
Description
Map Properties
Mapping Relationships
Relationship
Description
Publish to SmartPlant
Class
MapProperty
The MapProperty object corresponds to the IMapPropertyDef interface in the Tool Schema Data
Model diagram. In general, there is a MapProperty object in the tool schema for each SmartPlant
Electrical property that needs to be published or retrieved. The properties and relationships for a
MapProperty object can be viewed in the Edit Map Property Definition dialog box.
524
Description
UID
Name
Process
Criteria
Description
Exposed by Map
Classes
Scoped by Enumeration
525
Description
Map Property to Property This relationship defines the property in the SmartPlant
schema to which this tool property is to be published. If
this relationship is not defined, the property will not be
published. The relationship name in the diagram is
MapPropertyToProperty.
Property to Map Property This relationship defines the property in the SmartPlant
schema from which this tool property is to be
retrieved. If this relationship is not defined, the property
will not be retrieved. The relationship name in the
diagram is PropertyToMapProperty.
MapEnumList
The MapEnumList object corresponds to the IMapEnumListDef interface in the Tool Schema Data
Model diagram. In general, there is a MapEnumList object in the tool schema for each
SmartPlant Electrical enumerated list associated with a property that needs to be published or
retrieved. The properties and relationships for a MapEnumList object can be viewed in the Edit
Map Enumerated List Definition dialog box.
General
Property
Description
UID
Name
526
Relationship
Description
Scoped Map
Properties
Contains
Description
Maps To
Maps From
527
MapEnum
The MapEnum object corresponds to the IMapEnumDef interface in the Tool Schema Data Model
diagram. In general, there is a MapEnum object in the tool schema for each SmartPlant Electrical
enumerated list entry that needs to be mapped. The properties and relationships for a MapEnum
object can be viewed in the Edit Map Enumerated List Definition dialog box (the same dialog
box is used for MapEnumList objects.)
General
Property
Description
UID
Name
Description
Contained In
Mapping Relationships
528
Relationship
Description
Maps To
Maps From
529
Short Value
AA
BA
CA
Ammonia/Urea
DC
EA
530
Property
Value
Name
EngSystem
Display Name
Engineering System
Data Type
Select List
Select List
EngSys
Variable Length
Default Value
None
Display to User
Yes
Yes
Category
Miscellaneous
Depends on
None
531
3. In the Schema Editor, synchronize the authoring tool map schema for which you want to
define mapping.
The new enumerated list entry that you added in the authoring tool appears in the
Synchronization dialog box to be added to the tool map schema file.
532
7.
8.
9.
10.
11.
12.
Long Description
Number
AA
10111
BA
CA
Ammonia/Urea
10113
DC
10114
EA
10115
533
5. Above Unmapped SmartPlant properties on the right side of the dialog box, click New
Property Definition
534
on the toolbar.
Click File > Save > All Modified Files to save the SmartPlant schema extensions and the tool
map schema. For some tools, saving the tool map schema also saves changes to the tool
metadata database.
When you close the Schema Editor, the software prompts you to save your connection
information, user interface options, and loaded tool map schemas to a session file. Click Yes
in the message box to save the session file.
If you extend the SmartPlant schema, you must load the changes into the SmartPlant
Foundation database. For more information, see the SmartPlant Schema Editor User's Guide.
535
536
7. Click File > Save to save your changes in Data Dictionary Manager.
8. Click File > Exit.
537
3. After you open the SmartPlant schema in the Schema Editor, to the right of Another Schema
File in the Overall Workflows dialog box, click View.
4. On the View Schema dialog box, select Tree/Drag-Drop UML.
5. Click OK.
6. In the Map Environment, expand SmartPlant Electrical > Loaded Map Schemas >
SmartPlant Electrical Tool Schema.
7. Expand the Map Classes > PIDInstrumentLoop and select ELEElectricMotor.
8. Expand the Realized Interface Definitions
9. Repeat steps 7-8 for ELECable, ELEWire, and ELEInstrument.
IPBSItem is a common interface definition.
Synchronize
1. In the Schema Editor, synchronize the authoring tool map schema for which you want to
define mapping.
Synchronize Tool Metadata with the Tool Map Schema
538
2. Click OK in the Synchronize dialog box to update the tool map schema.
539
Click File > Save > All Modified Files to save the SmartPlant schema extensions and the tool
map schema. For some tools, saving the tool map schema also saves changes to the tool
metadata database.
When you close the Schema Editor, the software prompts you to save your connection
information, user interface options, and loaded tool map schemas to a session file. Click Yes
in the message box to save the session file.
If you extend the SmartPlant schema, you must load the changes into the SmartPlant
Foundation database. For more information, see the SmartPlant Schema Editor User's Guide.
540
541
542
Publishing Documents
In an integrated SmartPlant environment, the authoring tools share data and relationships when
you publish documents containing the data and relationships. The publishing process involves
selecting a document to publish, assigning it to a workflow when necessary, and specifying a
version and revision of the document if specified in SmartPlant Foundation. For most documents,
the software also publishes the data that is associated with the document when you publish.
The authoring tools (SmartPlant P&ID or SmartPlant Instrumentation, for instance) publish data in
.xml format. All leading and trailing spaces are trimmed from all strings and from all values
without units. These spaces will not appear in the published data file. The software then loads
the data from the .xml files to the SmartPlant Foundation database. After the data is loaded into
SmartPlant Foundation, you can retrieve the data into other authoring tools.
When you publish documents, the software does the following things:
Creates a new master document and the first revision in SmartPlant Foundation the first time
that you publish a particular document. From that point on, the software creates new versions
and revisions each time that you publish the document. The software relates revisions to the
master document. You can publish subsequent revisions into a workflow, which can be a
different workflow from the original publish action. Changes in the document status of a
related revision change the status of the subsequently published versions and revisions of the
document.
Publishes a visual representation of the document that you can view without the authoring
tool. For many applications, this is an Intergraph proprietary file, called a RAD file. The
viewable file can also be an Excel workbook or another viewable file type, such as .pdf or
.doc. Users can review and edit the visual representation of the document using SmartPlant
Markup.
Publishes associated data, depending on workflow approval. If the data is approved and
loaded, it is used for reporting and subsequent retrieval by downstream applications. The
software publishes only meaningful engineering data. The published data is not enough to
re-create the document in the original authoring tool.
The software publishes some document types without the associated data, such as reports
from authoring tools (for example, line lists in P&ID). You can submit documents published
without data to workflows just like documents with data. The document types and data that you
can publish depend on the authoring tool that you use.
For more information about revisions and versions, see the SmartPlant Foundation Web Portal
User's Guide.
Reasons to Publish
You can publish documents and associated data for several reasons:
To exchange and enhance data among tools, to avoid creating data multiple times in multiple
authoring tools
To report on common data that originates in multiple tools
To provide enterprise-wide accessibility to published documents
To manage change, including workflow history and document revision management
You can also publish documents to share information with users in other tools without going
through a formal workflow. To share data, you can publish a document to a For sharing
workflow that has only a load step so that the data is loaded into SmartPlant Foundation as soon
as you publish the document.
543
544
When publishing documents, the plant group type and uniqueness level set for publishable
item types must be the same as the settings for those item types in the retrieving tool.
When the retrieving tool is SmartPlant Instrumentation, the plant group type and
uniqueness level must be set to Unit for the following item types: Signal Runs, PDBs,
Motors, Heaters, Other Electrical Equipment, Instruments, and Circuits. Also the plant
group type must be set to Plant for Cabinets (the uniqueness level setting is not important
in this case).
In SmartPlant P&ID, the plant group type and uniqueness level can be set to any level
except for the highest plant group type. It is recommended that the plant group type and
uniqueness level are set to Unit in SmartPlant Electrical and SmartPlant P&ID for
SmartPlant Electrical publishable item types.
This command is available only if you have registered the active plant using the
SmartPlant Registration Wizard. For more information, see SmartPlant Engineering
Manager Help.
If you logged on to Electrical with a user name that is not defined in the integrated
environment, you are prompted to log on when you use this command.
The documents that appear in the Selected documents list on the Publish dialog box
when it first opens are documents that you selected in Electrical before you clicked the
Publish command.
2. Add any additional documents to the Selected documents list by clicking the Engineering
Tool, File System, or Find buttons and choosing other documents to publish.
545
The default setting for Publish Type is Changes Only. If the 3D model has not been
published before, the software automatically selects All and performs a complete
publish to ensure all filtered data is published and loaded into SmartPlant Foundation.
For subsequent publishes, select All to publish all filtered data in the 3D model, even
if it is unchanged. Select Changes Only to publish only the changes in the 3D model
since the last successful publish.
If the 3D model does not publish successfully during a delta publish, select All so that
data from the previous publish is published and loaded into SmartPlant Foundation.
Other SmartPlant applications do not support Publish Type. For these SmartPlant
applications, the default setting for Publish Type is All, and it cannot be changed.
5. Specify a method of publishing in the Operation box:
Click Publish to immediately start the publishing process as soon as you click OK.
Click Background publish to publish the selected documents immediately as a separate
process, allowing you to perform other tasks at the same time. When you use this feature,
an e-mail message alerts you when the process is complete.
Select the Scheduled publish option to indicate that the publish process should be run in
batch mode, if the authoring tool supports scheduled batch publishing.
Click OK to complete the publishing procedure.
When the publish is complete, a dialog box appears. If the View Log button on the dialog
box is enabled, messages are available concerning the operation. These messages may include
errors or warnings or even informational messages. Click the View Log button to see these
messages.
546
Publish Workflows
When a SmartPlant application publishes, the user can publish documents using a workflow. The
following list describes the delivered publish workflows and use cases for the workflows.
Workflow
Workflow Description
Auto-Correlate
AutoLoadPublish
AutoLoadPublishMerge
Use AutoLoadPublishMerge
when you intend to view or
navigate the complete plant in
one 3D view.
Correlate
Publish
547
Workflow Description
PublishWithDocLoad
Use PublishWithDocLoad
when you want to view the
document data in SmartPlant
Foundation before approval.
The approval step is added to
the To Do list.
You can quickly select the entire list by clicking Select All, or you can clear the entire list
by clicking Clear All.
548
Retrieving Documents
When you retrieve documents into an authoring tool, you are retrieving the document data that
was published by another authoring tool. For example, in SmartPlant Instrumentation, you can
retrieve engineering information from a published P&ID into the SmartPlant Instrumentation
database.
The authoring tools provide commands that let you select a document and retrieve it into that tool.
You can use either the SmartPlant > Retrieve command to open a wizard that assists you in
retrieving applicable documents, or with some authoring tools, you can configure an automatic
retrieval feature.
When you publish a 3D model, you must now enable the Scheduler and Loader in
SmartPlant Foundation to make the 3D model data document retrievable. The load, consolidate,
and merge tasks must complete successfully before the 3D model document can be retrieved.
The software trims all leading and trailing spaces from all strings and from all values
without units of measure. These spaces do not appear in the retrieved data file.
Additionally, you can access the Web Client through the SmartPlant > Browser command. This
allows you to select the document or documents that you want to retrieve from your Web Client To
Do List, the tree view, or by using the Web Client search functionality. After you select the
documents that you want to retrieve, you can use the Retrieve command on the Web Client
SmartPlant menu to start the retrieval process.
The Retrieve command provided in the authoring tools is slightly different from the Retrieve
command available in the SmartPlant Foundation Web Client. The Web Client presents a list of
documents from which you can select those you want to retrieve. However, when you use the
command from an authoring tool without first selecting documents, the software searches the
SmartPlant Foundation project for documents to retrieve, and these are presented in a list on the
Retrieve dialog box.
You can retrieve a document in two ways:
As published Retrieves only the data the authoring tool originally published with the
selected revision and version of the document. Retrieving as-published data retrieves the
.XML file the authoring tool published from the appropriate SmartPlant Foundation vault.
With the latest data Retrieves the latest data associated with the selected document in the
SmartPlant Foundation database. If another, more-recently published document contains
updates to objects in the selected document, the software retrieves the most current data in
the SmartPlant Foundation database for those shared objects. When you retrieve the latest
data, SmartPlant Foundation generates an .XML file containing the published data.
549
550
Retrieving the project breakdown documents and the PBS into SmartPlant Engineering
Manager creates the appropriate structures automatically.
When using SmartPlant Instrumentation, you must create the plant hierarchy according to the
PBS information in SmartPlant Foundation before you retrieve either the PBS or the project
definition document. You must create a plant hierarchy with at least three levels with a
minimum of one unit before you can retrieve the PBS and project definition document.
For certain document types, the tool schema definition may specify that To Do List tasks
(Create, Update, or Delete) will not be generated for those document types. For details, see
Suppress Generation of Tasks on Retrieve.
Design Basis
Objects that tools retrieve from other authoring tool documents can become the design basis for
objects in downstream documents. Objects that become the design basis for other objects can be
specific objects that get richer as they move through the lifecycle or can be schematic or logical
objects in one application that evolve into more detailed objects downstream.
Design basis is implicit based on retrieval; you do not have to define it. For example, a pump
retrieved from a PFD becomes the design basis for a pump in the P&ID. When you change
common properties for the pump and retrieve the changes into SmartPlant P&ID, tasks to update
property values automatically appear in the To Do List. The same process works for logical items
that are a design basis for other items, such as a stream in Aspen that results in multiple pipe
runs in SmartPlant P&ID, or a P&ID tag in SmartPlant P&ID can evolve into a control loop with
associated tag numbers in SmartPlant Instrumentation.
551
This command is available only if you have registered the active plant using the
SmartPlant Registration Wizard. For more information, see SmartPlant Engineering
Manager Help.
If you logged on to SmartPlant Electrical with a user name that is not defined in the
integrated environment, you are prompted to log on when you use this command.
The Retrieve command searches the SmartPlant Foundation project for documents that
are ready to be retrieved into your tool and displays them in the Documents to retrieve
list.
Items retrieved to, and that can also be created by SmartPlant Electrical, such as a motor,
can be renamed or deleted from SmartPlant Electrical.
2. In the Document type box, specify the type of document to be retrieved.
3. In the Show section, select Documents to be retrieved only to include documents that have
been retrieved previously and have been published again since the last retrieval. Select All
documents to include all revisions and types of documents. Select New documents only to
retrieve documents that have not been retrieved yet.
4. In the Documents to retrieve list, select the check box beside each document you want to
retrieve. To help identify the documents, review the details in the Type, Revision, Version,
and Last Retrieved columns.
To quickly select the entire list, click Select All. To quickly cancel the selections, click
Clear All.
5. For each document you checked, use the Retrieve Option column to specify whether you
want to retrieve the document with the latest data or retrieve it as published.
6. Click OK to retrieve the specified documents.
552
Select the Batch retrieve option if you want the retrieve process to run in batch mode. If you
select this option, an e-mail message will alert you when the process is complete. Otherwise,
the retrieval process begins when you click OK.
The Deleted and Unclaimed Objects document is retrieved automatically every time you
retrieve, if there is a newer version of this document since the last retrieval. The document is
not included in the list, but it is retrieved automatically, when necessary, to ensure that the
applicable information is updated.
When the retrieval process is complete, the following dialog box appears. If the View Log
button on the dialog box is enabled, messages are available concerning the operation. These
messages may include errors or warnings or even informational messages. Click View Log
to see these messages.
When an Update task is created in the To Do List, the units of measure used in properties are
automatically converted to the defaults for the plant. The units of measure used for properties
in Create tasks are converted to the plant defaults when the task is run.
By clicking the heading of columns on the To Do List, you sort the list by the values in that
column.
SmartPlant Electrical does not support task dependencies. For this reason, you must run Create
tasks in the appropriate sequence for items that have a dependency relationship. For example, if
the To Do List contains Create tasks for a motor and for some related process equipment, the
software cannot run the task for the motor first because in the SmartPlant Electrical database, the
process equipment ID already appears as a property of the motor. You must first run the Create
task for the process equipment, and only then for motor. In cases where the software fails to run
related Create tasks, you can restore the tasks and run them again in the correct sequence.
553
You can also open the Task Properties dialog box by double-clicking a task in the To
Do List.
4. On the Task Properties (see "Task Properties Dialog Box" on page 563) dialog box, click
the Details tab.
The properties available for each task depend on the type of task. For all types, you can
edit the status, description, and notes for the task. For Create and Update tasks, you can ignore
task properties when running a task (for details, see ). For Create tasks, you can edit the catalog
item being created and turn off or on the values assigned to different properties for that item. For
Update tasks, you can turn off or on the new values assigned to properties for the item.
You can select all the tasks on the To Do List by pressing CTRL + A.
You can select additional tasks that have a relationship with the selected tasks by clicking
Select Related Tasks
.
to select a filter.
If you cannot find a suitable existing filter, click New to create a new filter. For more
information about creating filters, see the Filter Manager User's Guide.
5. Click OK to apply the filter on the To Do List.
554
You can select all the tasks on the To Do List by pressing CTRL + A.
You can select additional tasks that have a relationship with the selected tasks by clicking
Select Related Tasks
.
You can select all the tasks on the To Do List by pressing CTRL + A.
You can select additional tasks that have a relationship with the selected tasks by clicking
Select Related Tasks
.
See Also
Display Deleted To Do List Tasks (on page 555)
555
You can also open the Task Properties dialog box by double-clicking a task in the To
Do List.
4. On the Task Properties (see "Task Properties Dialog Box" on page 563) dialog box, click
the Details tab.
5. Select the Ignore check box beside each property that you want the software to ignore when
running the task.
When you select to ignore a property, the software does not update that property when
you run the task for the current or for subsequent retrieve sessions. If the new value of the
property changes in the published data, on the next retrieve, that property is no longer
ignored. If you want to ignore the property only for the current retrieve session, clear both the
Activate and Ignore check boxes beside the property.
After running a task that includes ignored properties, that task is copied from the To Do List
to the ignored tasks list, where only the properties that were selected to be ignored appear on the
Details tab.
556
On the To Do List (see "To Do List Dialog Box" on page 561) dialog box toolbar, click
Refresh
.
557
SECTION 35
Menu Commands
In This Section
Publish Plant Groups Command (SmartPlant Menu) .................... 559
Publish Command (SmartPlant Menu) .......................................... 559
Find Documents to Publish Command (SmartPlant Menu) ........... 559
Retrieve Command (SmartPlant Menu) ........................................ 559
Compare with Published Version Command (SmartPlant Menu) . 560
Publish to External Analyzing Tool Command (SmartPlant Menu) 560
To Do List Command (SmartPlant Menu) ..................................... 560
Browser Command (SmartPlant Menu) ......................................... 560
Upgrade Schema Command (SmartPlant Menu) .......................... 560
559
560
SECTION 36
Properties Displays the Task Properties (see "Task Properties Dialog Box" on page
563) dialog box for the selected task. This dialog box shows the detailed properties of the
task. This command is available only when a single task is selected.
561
View Ignored Tasks Toggles the view between the To Do List and the ignored tasks
list. To make tasks available for running again the next time you retrieve data, you select them
from the ignored tasks list and click Delete
.
Filter/Sort Tasks Opens a dialog box that allows you to filter or sort the list of tasks by the
headings in the To Do List. This is useful if, for example, you want to filter or sort the tasks in
order to run tasks of one type only, such as Create tasks.
Select Related Tasks When you select one or more tasks, choosing this command selects
all tasks that have a relationship with the selected tasks, whether they are above or below those
tasks in the database hierarchy. For example, if process equipment such as a pump is
associated with a motor and you select a task for the motor, this command will also select related
tasks for the pump; likewise, if you select a task for the pump, this command will also select
related tasks for the motor. Note that only tasks that were retrieved from the same document are
selected.
Refresh Updates the information that is displayed in the To Do List. Since only one To Do
List is generated per plant, multiple users can be working in the To Do List at the same time, and
so the information can change at any time. You can use the Refresh command to stay
up-to-date.
Report Opens Microsoft Excel and runs a report on the contents of the To Do List. The
report is located in the reference data path.
Task List Populates automatically when you retrieve a document. This list provides
information about each task, including, for example, the type of the task, the item type, the item tag
affected by the task, and so forth. By clicking the heading of any of these columns, you can sort
the list by the values in that column. Alternately clicking the same column heading toggles the
562
563
Created
Displays creation details for the task.
By Displays the user name of the task creator.
Date Displays the date and time that the task was created.
Modified
Displays modify details for the task, other than for Create tasks.
By Displays the user name that last ran, modified, or deleted the task.
Date Displays the date and time that the task was last run, modified, or deleted.
Run
Displays details for the task when last run.
By Displays the user name that last ran the task.
Date Displays the date and time that the task was last run.
Deleted
Displays details for a deleted task. Note that this refers to deletion of the task itself, not of the item
that the task affects.
564
565
SECTION 37
Appendix
In This Section
SmartPlant Electrical Data Model .................................................. 567
Customizing Your Data .................................................................. 567
Electrical Calculations .................................................................... 569
Custom Validations and Calculations ............................................ 574
Switching the Plant Operational Mode .......................................... 579
Custom Common Properties Forms .............................................. 580
Typical Cable Block Diagram Utility Dialog Box ............................ 584
567
Appendix
568
Cell Usage
Circuit Mode
Circuit Type
Claim Mode
Conductor Arrangement
Conformity To Standard
Connection Point Type
Core Phase Usage
Count Quality
Current Transformer Ratio
Document Category
Document Sub Type
Document Type
Electrical Equipment Class
Electrical Equipment Sub Class
Equipment Type Identifier
FLA Calculation Flag
Framework Document Type
Frequency
Function
Grounding For Impedance Calculation
InOut
Instrument Function Type
Instrument Process Function
Item Project Status
KKS Component Key
KKS Component Key B1
KKS Equipment Unit Key
KKS Equipment Unit Key A1
KKS System Key
KKS System Key F1
KKS System Key F1 F2
kVClass
Length Units of Measure
LRC Code Letter
Model Item Type
Naming Type
Neutral Grounding
Number of Phases
Operating Mode
Origin Point
Phase Arrangement
Phase Usage
Plant Group Type
Plant Item Type
Appendix
Electrical Calculations
The software calculates electrical power requirements for motors based on the load data you
enter, which in turn comes from the motor manufacturer. On the Electrical Motor Common
Properties dialog box, Electrical Data tab (see "Electrical Data Tab (Electrical Motor Common
Properties Dialog Box)" on page 696), the software displays the results of the electrical power
requirement calculations.
569
Appendix
Power Factor Calculations
The software calculates the power factor and efficiency at the operating point by assuming a linear
relation between the standard values at 50%, 75%, and 100% of the motor rated power and
interpolating accordingly. For an operating point below 50% of the motor rated power, the
software extrapolates using the known slope between the values at 50% and 75% of the motor
rated power.
The following values apply to power factor calculations:
PF50 = power factor @ 50% (number between 0 and 1)
PF75 = power factor @ 75% (number between 0 and 1)
PF100 = power factor @ 100% (number between 0 and 1)
PF@DF = power factor @ demand factor (number between 0 and 1)
DF = demand factor (number between 0 and 1)
EF@OP = efficiency @ operating point (number between 0 and 1)
The graph shows how the software uses the user input values to calculate the power factor at a
given demand factor.
Based on the graph, the software calculates the power factor for different ranges of the demand
factor using the following formulas.
For a demand factor between 75% and 100%:
570
Appendix
Locked Rotor Current Calculation by Code Letter
(Applicable for NEC)
Indicating a code letter copies a fixed value from the LockedRotorIndicatingCodeLetters lookup
table to the kVA to HP ratio property.
Apparent Power (VA) = 1000 kVA to HP ratio * Motor Rated Power (hp)
This equation is applicable only when setting the conformity standard to NEC and the FLA
calculation to TABLES.
Absorbed Power
This is the output electrical power at normal operating point.
Demand Factor
This is the ratio of the load power requirement at a specified operating point to the rated power.
The demand factor influences the consumed electrical power of the load.
The software calculates the demand factor as the ratio of the absorbed power to the rated
power. The demand factor represents the operating point of the load that the software uses for
the calculations. Demand factor values can be inserted manually or calculated as the ratio of
absorbed power to rated power.
Power Factor
This is the power factor of a static load at rated or operating point. Power factor values can be
between zero and one, entered manually.
Efficiency
This is the efficiency of a static load at rated and operating point. Efficiency values can be between
zero and one, entered manually.
Equations
The software uses the following equation to calculate absorbed power (or demand factor):
571
Appendix
Electrical Power Calculations
The software calculates the rated, particular, and consumed load, that is, the electrical power,
using the equations below.
The following equations are used to calculate rated value for all static loads except for capacitors
and harmonic filters:
The following equations are used to calculate consumed value for all static loads except for
capacitors and harmonic filters:
The following equations are used to calculate consumed values for capacitors and harmonic
filters:
Reactive Load (kVAR) = Absorbed Power (kVAR)
572
For static loads, the software uses the values of the absorbed and rated electrical power to
calculate the electrical quantities.
For capacitors and harmonic filters, the active load property is disabled and has a null value.
For heaters, the reactive load property is disabled and has a null value.
Appendix
Calculation of Full Load Current
The software uses the following formulas to calculate full load current.
Where:
k=1 for DC and single phase AC
k=3 for three-phase AC
Rated voltage is the line voltage
573
Appendix
Implement Validation
1. Create a VB project with type ActiveX DLL.
2. On the project Properties dialog box, type a project name.
3. Ensure that the SPELCustomInf.tlb file is registered on the machine where you are going to
build your custom .dll file by using the regtlib command. This file should be located in the
folder where SmartPlant Electrical is installed and contains the appropriate interfaces that the
VB project must reference.
4.
5.
6.
7.
It is recommended that you compile the .dll file on a machine where you are going to run
SmartPlant Electrical, to facilitate testing of the code. In this case, you do not need to
register the .dll file.
If it is not possible to compile the .dll file on a machine where SmartPlant Electrical runs,
make sure that you register the ISPClientData3V2.tlb and SPELCustomInf.tlb library files
on the machine where you perform the compilation.
8. Open the Data Dictionary Manager (Data Dictionary Manager.exe) and click Database
Tables
.
9. Select the desired item (for example, Plant Item) and double-click the required property of
that item (for example, Name).
You need to have an understanding of the database table structure in order to decide
which item and property to select.
10. Beside Validation ID, type a ProgID which is usually made up of <VB Project name>.<Class
name>. For example, if the VB Project name is MyCustomValidation and the class name is
Class1.cls, the ProgID you would type is MyCustomValidation.Class1.
You can associate each item type property with one class only; however, the function
code in the class can specify any number of cases or conditions.
574
Appendix
11. Run SmartPlant Electrical to check that the code works (make sure that you are connected to
the correct plant).
The software performs the custom validation whenever you change the value of the property
in the Properties window, in the Tabular Editor, and if appropriate, in a Common Properties
dialog box. The software does not validate changed data input that originates from elsewhere,
for example, lookup tables.
The software performs custom validations prior to performing validations in the business
object layer; however, if a custom validation conflicts with a business layer rule, the software
ignores the custom validation.
If a custom validation affects other properties that have their own custom validation definitions,
the software only performs the validation for the property where you change the value directly;
it ignores the custom validations for the other properties.
When performing a total bus load validation, the software accounted only for those items that
are defined as consumers. In addition to loads, you can define other electrical items as
consumers. These items are converting equipment items, local panels, and junction boxes.
To define an item as a consumer, you have to set the Is Load property in the Properties
window for that item to True or define this electrical item as a Consumer in the Common
Properties dialog box of that item.
575
Appendix
Implement Calculation
1. Create a VB project with type ActiveX DLL.
2. On the project Properties dialog box, type a project name.
3. Ensure that the SPELCustomInf.tlb file is registered on the machine where you are going to
build your custom .dll file. This file should be located in the folder where SmartPlant Electrical
is installed and contains the appropriate interfaces that the VB project must reference.
4.
5.
6.
7.
It is recommended that you compile the .dll file on a machine where you are going to run
SmartPlant Electrical, to facilitate testing of the code. In this case, you do not need to
register the .dll file.
If it is not possible to compile the .dll file on a machine where SmartPlant Electrical runs,
make sure that you register the ISPClientData3V2.tlb and SPELCustomInf.tlb library files
on the machine where you perform the compilation.
8. Open the Data Dictionary Manager (Data Dictionary Manager.exe) and click Database
Tables
.
9. Select the desired item (for example, Plant Item) and double-click the required property of
that item (for example, Name).
You need to have an understanding of the database table structure in order to decide
which item and property to select.
10. Beside Calculation ID, type a ProgID which is usually made up of <VB Project name>.<Class
name>. For example, if the VB Project name is MyCustomValidation and the class name is
Class1.cls, the ProgID you would type is MyCustomValidation.Class1.
11. Run SmartPlant Electrical to check that the code works (make sure that you are connected to
the correct plant).
576
Appendix
577
Appendix
You can use this example code to write your own programming routine for a different item type.
1. In the General Declarations section of the class add the following lines:
Option Explicit
Implements SPELCustomInf.ISPELItemValidation
Private m_LastErrorMessage As String
2. Implement the SavingItem method as follows:
Private Property Get ISPELItemValidation_LastErrorMessage() As String
ISPELItemValidation_LastErrorMessage = m_LastErrorMessage
End Property
Private Function ISPELItemValidation_SavingItem(ByVal objISPItem As
ISPClientData3.ISPItem) As Boolean
Dim nDemandFactor As Double
Dim nCapacitorRatedPower As Double
Dim nAbsorbedPower As Double
Dim objProperty As ISPPropertyInf.ISPProperty
On Error GoTo ErrHandler
If objISPItem.ItemType.Name <> "Capacitor" Then GoTo Exit_Proc 'Works
Only for 'Capacitor'
'Get the fields that are involved in calculation with SI(The
International System of Units) values
nCapacitorRatedPower = CDbl("0" &
objISPItem.Attributes("CapacitorRatedPower").SIValue)
nAbsorbedPower = CDbl("0" & objISPItem.Attributes("AbsorbedPower").SIValue)
nDemandFactor = CDbl("0" & objISPItem.Attributes("DemandFactor").Value)
If nCapacitorRatedPower = 0 Then GoTo Exit_Proc
in CapacitorRatedPower, nothing is calculated.
578
Appendix
GoTo Exit_Proc
End If
'Calculate Absorbed Power if the Absorbed Power has been changed
Set objProperty = objISPItem.Attributes("AbsorbedPower")
If objProperty.IsDirty Then
nDemandFactor = nAbsorbedPower / nCapacitorRatedPower
objISPItem.Attributes("DemandFactor").Value = CStr(nDemandFactor)
GoTo Exit_Proc
End If
Exit_Proc:
'Set return value to True if the calculation is OK or to False if something is wrong
ISPELItemValidation_SavingItem = True
Set objProperty = Nothing
Exit Function
ErrHandler:
'If something is wrong, display an error message.
m_LastErrorMessage = Err.Description
Resume Exit_Proc
579
Appendix
580
Appendix
11. Type the following code for the module class that you created:
Option Explicit
Implements SPELCustomInf.ISPELCustomForm
Private
String,
Set
Dim
On Error GoTo EH
Set customFrm = Forms.Add(strFormName)
Set ISPELCustomForm_CreateForm = customFrm
EXIT_FUN:
On Error Resume Next
Set customFrm = Nothing
Exit Function
EH:
MsgBox "Form " & strFormName & " does not exist", vbOKOnly +
vbExclamation, "Error"
Resume EXIT_FUN
End Function
12. Click Project > Add Module.
13. Type the following text:
Option Explicit
14.
15.
16.
17.
581
Appendix
f.
For each SmartPlant Electrical ComboBox control, type the following for the DropDown
event:
g_objEdit.OnDropDown [control name]
If you are working with an array of controls, for each control, add the required indexes in
parentheses.
This concludes the form creation procedure. Now you have to ingrate the new custom form in
SmartPlant Electrical. For details, see Define Custom Forms in SmartPlant Electrical (on page
582).
582
Appendix
<ItemType Name="Generator" DefaultProgId =
"CustomForm.CustomEdit">
<Forms>
<Form Name = "Cable_Form1" ProgId
="CustomForm.CustomEdit" Description = "Power Cables" />
<Form Name = "Cable_Form2" ProgId
="CustomForm.CustomEdit" Description = "Instr. Cables" />
</Forms>
</ItemType>
</ItemTypes>
When editing the SPELCustomForms.xml file, remember the following:
For each item type, there has to be an <ItemType> node that points to the appropriate Visual
Basic project and module class according to the following syntax:
<ItemType Name="Motor" DefaultProgId = "[VB Project Name].[Module Class
Name]">
For example:
<ItemType Name="Motor" DefaultProgId = "CustomForm.CustomEdit">
If a form that you created belongs to a project different from the one indicated in the
DefaultProgId node, add a new line in the <Forms> node that points to the required project.
Under the <ItemType> node, there has to be a <Forms> node under which you add all the
forms that you want to have for this item type.
Each <Form Name> node must have a name definition and it can have a ProgId and
description definitions. Use the following syntax:
<Form Name = "[Form Name]" ProgId ="[VB Project Name].[Module Class
Name]" Description = "[Text]" />
Note the following:
There must be a name definition for each form. This name will appear on the Select
Common Properties dialog box, in the Common Properties Form field.
You can define a ProgId different from the default ProgId or you can omit this definition if
you like. If there is no ProgId for a particular form, the default ProgId will be in use.
The Description definition that you type here will appear on the Select Common
Properties dialog box, in the Description field. You can omit the Definition description if
you like.
If you want to add another form for a different item type, define an additional <ItemType
Name> node for that form.
If want to share your custom forms with another user, copy the DLL file that was created by the
Visual Basic project and the SPELCustomForms.xml file to the SmartPlant Electrical
installation folder of the user who will share your custom forms. There is no need to copy the
SPELCustomForms.xsd file as it is provided with every installation.
Remember that you must register the DLL file once it is copied to another
computer.
583
Appendix
584
Appendix
File name Allows you to type and display the name and file path of the ZIP file that you want to
save or unzip. Click
to navigate to the appropriate location.
Run Saves the data as a Zip file or integrates the unzipped typical CBD data depending on the
option you selected above.
Change Plant Allows you to change the plant where you want to save the ZIP file or where you
want to integrate the unzipped typical CBD data.
585
SECTION 38
Menu Commands
New > Item Command (File Menu)
Creates a new item or adds a node under the selected node in the Reference Data Explorer or
Electrical Index.
Clicking on the down-arrow of the File menu button above accesses a list of the associated
commands. Clicking on the File menu button itself repeats the last command you used from the
File menu.
587
Menu Commands
588
Menu Commands
589
Menu Commands
On the Preferences dialog box, General tab, under Open after creating or duplicating an
item, you can specify whether to open the Item Tag dialog box when you duplicate the item.
Some items have a Common Properties dialog box from which you can edit the most
common properties for the item. You can specify in the preferences to open this dialog box
directly when you duplicate the item.
590
Menu Commands
591
Menu Commands
592
Menu Commands
593
Menu Commands
If you choose this command without first opening a pertinent document, all the options in the
dialog box options appear in read-only mode.
If you click outside the drawing, this command is not available. To access this command, first
select an item in the drawing.
594
Menu Commands
595
Menu Commands
Logging into Unit 101 filters out all items except for those associated with Unit 101, Area 100, and
Plant 1. The software filters out items associated with Unit 100 or with Area 200 and its units (Unit
200, Unit 201).
596
Menu Commands
597
Menu Commands
598
Menu Commands
599
Menu Commands
600
Menu Commands
601
Menu Commands
602
Menu Commands
603
Menu Commands
604
Menu Commands
605
Menu Commands
606
Menu Commands
607
Menu Commands
Table Properties
Opens the Table Properties dialog box, which enables you to specify the item type (such as
Battery Bank, Cable, and Load), a layout for the item type which determines how the software
presents the item type data, and if required, a filter.
Save Settings
Stores the table layout and the order and width of the Tabular Editor columns.
Auto Filter
Allows you to filter the tags according to various values that the selected property contains. When
you click the Auto Filter command, arrows appear at the top of each column. Click on the arrow
at the top of the column that contains the data you want to filter on and choose the value from the
list that appears. You can include more than one property in the auto filter of your table, creating
a chained filter.
Click this command again to remove the filter.
To create more elaborate filters and displays, you need to use the Table Properties command
and enter options on the Table Properties and Advanced Table Properties dialog boxes.
Freeze Panes
Allows you to scroll through the Tabular Editor while keeping the display of specified rows and
columns constant. For instance, the first column can contain the item tag, but you want to always
see the item tag as you scroll to the right end of the rows to view the supplier.
608
SECTION 39
609
to bring up
Very long descriptions cannot be displayed in their entirety in labels, reports, and so forth.
610
Properties
Show only properties that have data values Select to filter the list of properties so that only
those properties that have data values are displayed.
You can display properties alphabetically or by categories by clicking the corresponding
display mode button. Click
to display alphabetically. Click
to display by categories.
Property Displays the properties of the selected equipment type.
Value Enter the value of the property that appears in the Property box to search for items that
have that value only. You can type an asterisk (*) as a wildcard character to find multiple
characters or a question mark (?) as a wildcard character for a single character. If the property
has values that appear in a list, select the desired value from the list.
Results
Displays the search results with a list of the items that correspond to the criteria that you entered in
the upper part of this dialog box.
No. The sequence of the item as it appears in the list of results.
Item Tag The tag name of the item.
Equipment Type The equipment type to which the item belongs.
Find Now Click to start a search of the items that correspond to the equipment type, and where
relevant, the other filter criteria that you select for the search.
New Search Click to clear all search criteria in preparation for a new search.
Results Displays a list of the items that meet the search criteria. Highlight an item on the list
and select it by doing one of the following:
Press the ENTER key.
Double-click the item.
Where you are allowed to select more than one item, for example when adding typical
control stations to a motor profile, press the CTRL or SHIFT keys to make multiple
selections, and then click OK or Apply.
OK Click to navigate to or select items that are highlighted in the Results window and close the
Find dialog box.
Cancel Click to close the Find dialog box without navigating to or selecting highlighted items.
You can also press the ESCAPE key to cancel the operation.
Apply Click to navigate to or select items that are highlighted in the Results window. This
option is useful when it is possible to select more than one item and you want to do so without
closing the dialog box.
611
612
Electrical Engineer display options for buses, incomers, bus risers, and auxiliary contacts
Allows you to display in the Electrical Engineer the names of associated PDB item tags as part of
the names of buses, incomers, bus risers, and auxiliary contacts.
Include associated PDB item tags Displays in the Electrical Engineer buses, incomers, and
bus risers together with the associated PDB item tags. For example, MCC 200 \ Bus A.
SLD drawings
Allow you to set general preferences for SLD generation.
613
SLD margins
Define the default unit of measure for SLD margins and distance between the page edges and the
SLD drawing so that the drawing does not overlap the title block and the SLD border.
Units Select the unit of measure for the SLD margins (mm or inches). The unit of measure for
top, bottom, left and right margins changes dynamically, according to the selection that you make.
Top Allows you to type the value for the top drawing margin.
Bottom Allows you to type the value for the bottom drawing margin.
Right Allows you to type the value for the right drawing margin.
Left Allows you to type the value for the left drawing margin.
614
(Check Box)
Account for converting equipment power losses When running bus load calculations,
allows you to instruct the software to calculate the total electrical consumption taking into account
converting equipment power losses. The software adds these power losses to the upstream
feeding bus and takes them into accounts as continuous loads. The same losses are also taken
into account in the All Feeder Load Summary report.
615
616
617
618
Sort Items by Specifies the value and the order that you want to display items in the drawing
software.
Ascending Sorts the selected items in order from the beginning of the alphabet or the lowest
number, depending on the type of entries in the select list.
Descending Sorts items starting from the end of the alphabet or the highest number,
depending on the type of entries in the select list.
Then by Sorts items by an additional value. For example, if you want to sort a select list by its
dependent values, you could sort entries with the same dependent value by their Short Value or
Value.
Clear All Resets all the sorting criteria to none, removing any changes that you made.
619
Associations
Associated Drawings Dialog Box
Allows you to view all drawings that are associated with a specific item in the Electrical Index,
filter them by drawing type, and then select and open a drawing.
Filter by drawing type
Filters the drawings by their types. The types are:
All drawings
Schematics
Wiring diagrams
Cable block diagrams (CBD)
Single line diagrams (SLD)
PDB layouts
Associated Drawings
Document Displays the name of the document.
Description Displays a description of the document. (Only available if a description was
entered in the common properties of the selected item).
Drawing Type Displays the drawing type.
Open Drawing Opens the selected drawing.
Cables
Apply Reference Data to Project Cables Dialog Box
Enables you to update data in project cables in batch mode where the reference data for those
cables has changed.
Data window Displays project cables for which data has changed in the reference cables
associated with those project cables, with details of the cable category, cable tag, cable formation,
and the reference cable. Beside each cable name is a check box that allows you to select the
cable for applying the new reference data. For a parallel cable assembly, the software displays
only the first cable of the assembly; however it applies the reference data to all the cables in the
assembly.
Select all Allows you to select all the cables in the list for applying updated reference data.
Apply Applies the new reference data for the selected cables.
Close Closes the dialog box.
Compare Opens the Compare Project and Reference Cable Data dialog box (on page 642),
from which you can compare for the selected project cable the properties that have different
values in the project and reference cables.
620
621
You can specify the order of the cables that have not been assigned yet and organize these
cables either in a descending or alternate order. You set the sorting method on the General
page in Options Manager. If you select the Descending method, the software sorts the cables
starting with the longest cable and then goes down to the shortest one. If you select the
Alternate method, the software starts with the longest cable, then with the shortest, then with
the second longest and then back to the shortest again, and so on.
If you need to add or modify data values for a particular cable, you can do so by selecting the
desired row and then clicking Common Properties. You can then edit the cable data as
needed.
You can define and customize pulling areas in the Data Dictionary Manager.
Select Select the check box beside each cable that you want to include in the automatic drum
assignment. You can only select a cable for assignment to a drum if a cable length and pulling
area are defined.
Cable Tag The identifying tag of the project cable.
Cable Category Displays the category that defines the purpose for which the cable is used:
Power, Instrumentation, Control, or Grounding.
Cable Specification Displays the family of reference cables to which the reference cable
associated with the project cable belongs.
Cable Formation Displays the cable formation (number and size of conductors) for the
reference cable.
Actual Length Displays the actual length of the cable, as calculated by the software.
Pulling Area Displays the pulling area assigned to the cable.
Select all Selects this check box to select all the available cables for inclusion in automatic
drum assignment, provided that the cable length and pulling area are defined. Clear to clear the
selection for all the cables.
Common Properties Opens the Cable Common Properties dialog box for the selected cable
to allow you to update the cable properties.
622
From
Describes information relating to the connection point for one side of the cable.
Tag Indicates the name of the item associated with this cable side. If you associate the From
cable side with a circuit that belongs to a PDB, the software displays the path of the circuit tag:
PDB/ bus/(cell)/ circuit.
Description Displays the description that is taken from the description of the tag associated
with the From side of the cable.
Dissociate existing connection Dissociates an item that already has an association with this
cable side.
Find Opens the Find dialog box, where you can select an appropriate item to associate.
Clear Clears the selection that appears in the Tag and Description boxes.
Gland Displays a gland associated with this cable side, if appropriate.
Dissociate gland Dissociates a gland that already has an association with this cable side.
Find Opens the Find dialog box, where you can select an appropriate cable gland that you
want to associate.
Clear Clears the selection that appears in the Gland box.
To
Describes information relating to the connection point for the opposite side of the cable to the
From side.
Tag Indicates the name of the item associated with this cable side. If the item that you
associate is connected to a PDB/Cell/Circuit, the software displays the association on the From
side.
Description Displays the description that is taken from the description of the tag associated
with the To side of the cable.
Dissociate existing connection Dissociates an item that already has an association with this
cable side.
Find Opens the Find dialog box, where you can select an appropriate item to associate.
Clear Clears the selection that appears in the Tag and Description boxes.
Gland Displays a gland associated with this cable side, if appropriate.
Dissociate gland Dissociates a gland that already has an association with this cable side.
Find Opens the Find dialog box, where you can select an appropriate cable gland that you
want to associate.
Clear Clears the selection that appears in the Gland box.
Cable Tag Displays the name of the cable. Select the check box beside the cable tag to select
the cable for associating with specified items and glands.
Description Displays the description for the cable, if defined.
Cable Category Displays the cable category: Control, Instrumentation, or Grounding.
Cable Specification Displays the cable specification, if defined.
623
624
625
Construction
Describes the physical characteristics related to the construction of the cable. All the properties
in this section except for the Conductor arrangement and Color pattern properties are
read-only. The available values depend on the conductor arrangement that you select.
Conductor arrangement Defines the number and arrangement of the conductors in the cable
(not applicable for instrumentation cables). Your selection filters the list of available reference
cables to display only those cables that match the cable formation that you have selected. When
sizing a power cable, the software searches only for those reference cables that have the selected
conductor arrangement. The following standard options are available:
Single core cable Creates a current-carrying cable with a single core. For this option,
you can specify an arrangement of any number of single-core conductors, for example, 3
single-core cables, but you cannot specify any additional conductors.
2-core cable Creates a cable with two current-carrying conductors and no additional
conductors. You cannot modify the cable construction for this option.
2+1-core cable Creates a cable with two current-carrying conductors and one
additional conductor. You cannot modify the cable construction for this option.
3-core cable Creates a cable with three current-carrying conductors and no additional
conductors. You cannot modify the cable construction for this option.
3+1-core cable Creates a cable with three current-carrying conductors and one
additional conductor. You cannot modify the cable construction for this option.
3+2-core cable Creates a cable with three current-carrying conductors and two
additional conductors. You cannot modify the cable construction for this option.
Multicore cable Creates a cable with multiple conductors. For this option, you can
specify any number of conductors and additional conductors.
You can change the names of the standard conductor arrangement items in the Data
Dictionary Manager. However, the software performs calculations according to the position
in the list of the item that you select. For example, a 2-core cable is always the second item in
the list.
626
627
Command Buttons
Compare to Reference Click to open the Compare Project and Reference Cable Data dialog
box (on page 643), from which you can compare reference cable properties that have changed
since the creation of the project cable. From this dialog box, you can also copy the updated
reference data to the project cable if required.
Drum assignment
Allows you to assign the current cable to a cable drum and lock the drum to the current cable if
needed.
628
Cable routing
In this group box, you build the routing path for the cable that you are editing.
Select predefined route When you click Find, allows you to select a predefined route to use
as a basis for the cable routing definition.
Copy route from cable When you click Find, allows you to select routing from another cable to
use as a basis for the cable routing definition.
Segregation level You must select a segregation level for the cable if you want to perform
routing. The segregation level of the cable must match the segregation level of all the cableway
segments to which you assign the cable. Note that once you have added at least one segment to
the routing, you cannot change the segregation level; to do so, you must first remove all the
segments.
Find Opens the Find dialog box, from which you can select as predefined route or a cable with
routing for copying, according to the option you have selected. Note that only routes or cables
that belong to the current segregation level are available for selection.
Save as new route Allows you to save the current routing definition as a new predefined route.
Route details
Displays the cableways and segments that make up the routing. Note that only those segments
that belong to the current segregation level are available for selection.
629
Design data
Provides information about the physical characteristics of the cable.
Note that for parallel cables, when you change estimated cable length or design cable length, the
software automatically changes the values for all of the other parallel cables.
Changing a value that affects the Actual design/installed length of the current
cable and if this Actual design/installed length value has already been used to size the cable,
the software automatically recalculates the voltage drop. If the new Actual design/installed
length exceeds the sizing parameters of the current cable, you will need to resize the cable by
clicking the Perform Sizing button on the Sizing Data tab. The software displays an appropriate
message to this effect in the Calculation information box on the Sizing Data tab and turns on
the Sizing required flag on the General tab of the Cable Common Properties dialog box.
Use external routing length Instructs the software to overwrite the Actual design/installed
length value with the existing External routing length value. If you select this check box, and
the External routing length property does not have a value, the software uses a value of zero in
calculations. If you clear this check box, the software uses the value of one of the following
properties: Estimated length, Design length, or Routing length.
Estimated length Allows you to enter the estimated length of cable before installation with
appropriate units of measure. In sizing calculations, the software uses this value if you do not
specify a design length. You can specify the default project units of measure in the Data
Dictionary Manager.
Design length Allows you to enter a more accurate length for the cable after installation with
appropriate units of measure. In sizing calculations, this value overrides the estimated
length. You can specify the default project units of measure in the Data Dictionary Manager.
Routing length If you added routing information, displays the total length of the segments that
you defined.
External routing length If you retrieved routing information from SmartPlant 3D, the software
can use the routing length obtained with the retrieved data, provided that you select the Use
external routing length check box.
External routing path Displays the external routing path taken from SmartPlant 3D, provided
that you select the Use external routing length check box. To view the full path click the ellipsis
button
.
Tail 1 Allows you to type a value for the spare tail length at one end the cable, if you require.
630
Installed data
Allows you to enter data so that the software can take into account the actual installed data of the
current cable. The software calculates the installed length based on the values that you enter for
Marked length side 1 and Marked length side 2 fields.
Marked length side 1 Allows you to type a value for the marked length on side 1 of the
cable. This is a marking that the vendor usually marks at standard fixed metered intervals along
the entire length of the cable.
Marked length side 2 Allows you to type a value for the marked length on side 2 of the
cable. This is a marking that the vendor usually marks at standard fixed metered intervals along
the entire length of the cable.
Installed length A calculated field that displays the actual installed length of the cable. The
software calculates this value if you enter both Marked length side 1 and Marked length
side 2 values. The result is the absolute delta between the Marked length side 1 and
Marked length side 2 values. If you do not enter both Marked length side 1 and
Marked length side 2 values, you can type in the installed value yourself.
Cable installed Allows you to define the cable as installed in the field. Once you select this
check box, the software overwrites the value under Actual design/installed length with the
Installed length value. The software uses the Actual design/installed length value to calculate
cable sizing and optimize cable drums.
Command Button
Compare to Reference Opens the Compare Project and Reference Cable Data dialog box (on
page 643), from which you can compare reference cable properties that have changed since the
creation of the project cable. From this dialog box, you can also copy the updated reference data
to the project cable if required.
631
If you make electrical associations in the Electrical Engineer or on the Feeder Data tab of the
Electrical Motor Common Properties dialog box, the software populates the Tag property
on the From cable side with the appropriate data.
If you associate a power cable with a load that you previously associated with a circuit, the
software inserts the cable between the circuit and the load and populates the Tag property
with the circuit data.
Once you have made an association for a power cable, all further changes, including
dissociation, must be made in the Electrical Engineer.
Gland Displays a gland associated with this cable side, if appropriate.
Find Opens the Find dialog box, where you can select an appropriate cable gland to associate.
Dissociate Dissociates a gland that already has an association with this cable side.
To
Describes information relating to the connection point for the opposite side of the cable to the
From side. For a power cable, this property indicates the cable side that is closer to a consumer.
The software does not allow you to make parallel connections or change existing
parallel connections of cables on the Cable Common Properties dialog box. Parallel cable
connections or changes of parallel associations can be carried out only in cable block diagrams.
Tag Indicates the name of the item associated with this cable side. For a power cable, if you
associate the To cable side with a load, the software uses data from the load to populate some of
the properties on the Sizing Data tab; if the load is connected to a PDB/Cell/Circuit, the software
displays the association on the From side.
Description Displays the description that is taken from the description of the tag associated
with the To side of the cable and is read-only.
Find Opens the Find dialog box, where you can select an appropriate item to associate. (Not
available if one of the ends of the current cable is connected in parallel.)
632
If you associate a power cable with a motor by applying a profile, the software populates the
To property with the motor tag.
Once you have made an association for a power cable, all further changes, including
dissociation, must be made in the Electrical Engineer.
Gland Displays a gland associated with this cable side, if appropriate.
Find Opens the Find dialog box, where you can select an appropriate cable gland to associate.
Dissociate Dissociates a gland that already has an association with this cable side.
The software performs sizing for 1- and 3-phase supplies only, using a different voltage drop
formula for each option.
The software automatically recalculates the voltage drop after you change this value for a
cable that has already been sized. If the value you enter exceeds the sizing parameters of
the current cable, you will need to resize the cable by clicking the Perform Sizing button on
this tab. The software displays an appropriate message to this effect in the Calculation
information box on this tab and turns on the Sizing required flag on the General tab of the
Cable Common Properties dialog box.
633
634
Derating factors
The basic ampacity of the cable applies to standard conditions that the manufacturer
specifies. Under actual operating conditions, such as a higher environmental temperature, or a
location where several cables are routed close to one another, the ampacity changes. The
derating and utilization factors take into account the operating conditions of the cable.
Derating factor Allows you to enter a value for the derating factor, which the software uses to
calculate the cable derated ampacity under actual operating conditions. The software multiplies
the basic ampacity by the derating factor to obtain the derated ampacity. A value of less than 1
means that the derated ampacity is lower than the basic ampacity, and this will result in a
requirement for a larger size cable.
Utilization factor Enter a value between 0 and 1 to represent an additional factor that derates
the cable ampacity. If you do not need to use this property, set the value to 1. The software
multiplies the basic ampacity by this factor to obtain the derated ampacity.
Ambient temp. factor Enter a value between 0 and 2 to represent a temperature factor that
affects the derated cable ampacity. For the software to apply this factor to the calculation, in the
Options Manager, you must first set the value of the Apply Temperature Correction Factor to
Cable Sizing property to Yes; setting the value of the property to No is the equivalent of using a
value of 1 for the temperature factor.
If you change any of the derating factors for a sized cable, the software automatically
selects the Sizing required check box on the General tab.
The allowable voltage drop must have a value greater than zero. To ignore the voltage drop
in the sizing calculation, type a value of 100.
The software automatically recalculates the voltage drop after you change this value for a
cable that has already been sized. If the value you enter exceeds the sizing parameters of
the current cable, you will need to resize the cable by clicking the Perform Sizing button on
this tab. The software displays an appropriate message to this effect in the Calculation
information box on this tab and turns on the Sizing required flag on the General tab of the
Cable Common Properties dialog box.
635
The allowable voltage drop must have a value greater than zero. To ignore the voltage drop
in the sizing calculation, type a value of 100.
The software automatically recalculates the voltage drop after you change this value for a
cable that has already been sized. If the value you enter exceeds the sizing parameters of
the current cable, you will need to resize the cable by clicking the Perform Sizing button on
this tab. The software displays an appropriate message to this effect in the Calculation
information box on this tab and turns on the Sizing required flag on the General tab of the
Cable Common Properties dialog box.
Calculated Displays a calculated value of the percentage voltage drop when starting the load,
using the estimated or design length of the cable. This property applies to motors only.
Short circuit
If you want to include short circuit calculations in the cable sizing, you enter values for the
properties in this section. The software uses this data along with the coefficients that are found in
the Conductor Material Coefficients and Conductor Insulation Temperatures lookup tables
to calculate the minimum required conductor cross-section area. Suitable values must be
available in these tables for the software to be able to perform the calculation.
Use short circuit cable sizing Select to enable and activate the short circuit properties and
algorithm when you want the cable sizing to include short circuit calculations.
Duration Allows you to type the maximum time for which the cable is expected to withstand a
fault short circuit current until a protection device interrupts the current flow in the circuit.
Fault current Allows you to type the maximum short circuit fault current that can flow through
the cable, and for which the cable needs to be sized.
Required area (cmils) Displays the calculated minimum conductor cross-section area
required for the cable to meet the short circuit criteria that you specify.
Protection setting
Allows you to specify cable sizing based on the rated current for a protection device such as a fuse
or circuit breaker, rather than using the load current.
Include protection device Select to specify the rated current of the protection device for use in
sizing calculations. Clear to use the load current value.
Protection settings Allows you to type the rated current of the protection device for use in
sizing the cable. The software automatically recalculates the voltage drop after you change this
value for a cable that has already been sized. If the value you enter exceeds the sizing
parameters of the current cable, you will need to resize the cable by clicking the Perform Sizing
button on this tab. The software displays an appropriate message to this effect in the Calculation
information box on this tab and turns on the Sizing required flag on the General tab of the
Cable Common Properties dialog box.
Sizing results
Shows the outcome of the calculations based on the load data that you supply for the cable. All
the information is read- only.
If the cable is connected to a load for which you select the Consumer check box, the
software uses the electrical values of the load to size the cable.
636
637
638
639
Assigned cables
Displays the cables assigned to the current cable drum. Note that you can only assign cables
after you have selected a reference cable and a pulling area.
Locked Allows you to lock a cable to the current drum. Note that locking a cable to a drum
makes it impossible to unassign this cable from the assigned drum or change the assignment to
another cable drum. You can unlock the drum from the current cable by clearing the Locked
check box here or clear the Lock to drum check box on the Design Tab of the Cable Common
Properties dialog box.
When using the Assign Drums to Cables wizard, the software optimizes the
assignment of cables to drums. The optimization mechanism disregards all the cables that
either have been locked to drums or already have been installed. Installed and locked cables
are, therefore, fixed on those drums. When calculating the Total cable length left on drum
value, the optimization mechanism subtracts the length of the locked and installed cables
from the maximum drum capacity. For details about the optimization process, see
Optimization of Cable Drum Assignment (on page 178).
640
641
642
643
Wire definitions
Sequence Indicates the sequence of the conductor in the cable or set.
Color Select a color for each conductor.
Sequence Indicates the sequence of the conductor in the cable or set.
Color Select a color for each conductor.
Add Adds an empty row below the currently selected row.
Insert Adds an empty row above the currently selected row.
Up Moves the selected row above the previous row each time that you click this option. The
order of the rows affects the order of the conductors in the cable or set.
Down Moves the selected row below the next row each time that you click this option. The
order of the rows affects the order of the conductors in the cable or set.
Remove Removes the currently selected conductor.
644
Cable definition
Select from cable library Choose this option to select an existing reference power cable.
Reference cable Display the power cable you selected on the Select Reference Cable dialog
box.
Opens the Select Reference Cable dialog box, which contains reference power cables.
Specify construction Select this option to define a new power cable based on a specified
conductor arrangement. This option is available only when you define a reference power cable
for an item profile and a reference circuit.
Conductor arrangement Defines the number and arrangement of the conductors in the power
cable. The following standard options are available:
Conductors Specifies the number of conductors within the power cable used for carrying the
current, excluding the neutral, the ground, or additional conductors. If you selected Single-core
or Multicore as the conductor arrangement, this option allows you to specify the number of
conductors or cores in the cable that carry the electric current.
Additional conductors If you selected Multicore as the conductor arrangement, this property
specifies the number of additional non-current-carrying conductors, such as ground wires.
OK Inserts the specified power cable between items of equipment under the equipment item
you selected in the Electrical Engineer.
645
Thread
Thread type Allows you to select the thread type used for the gland.
Thread size Allows you to select a standard code used to represent the thread size.
646
Filter criteria
Allows you to select a set of criteria to filter the available reference cables from which you select to
replace the existing reference cables.
Cable category Displays the category that defines the purpose for which the cable is used,
that is, power, control, grounding, or instrumentation. The category depends on the folder from
which you selected the cables and is read-only.
The software replaces cables of the same category. For example, you can only replace a
power cable with another power cable.
Cable specification Allows you to select a specification that defines a family of cables, each
consisting of a specific group of reference cables.
Conductor arrangement Allows you to select an option that defines the number and
arrangement of the conductors required. Only those reference cables that correspond to a
selected conductor arrangement appear. The following standard options are available:
Single core cable Selects current-carrying cables with a single core.
2-core cable Selects cables with two current-carrying conductors and no additional
conductors.
647
Replacement cable
Shows the reference cable and its cable formation. This cable is used to replace the selected
cables.
Reference cable Select the reference cable that you want to use for replacing the selected
cables.
Cable formation Displays the cable formation (number and size of conductors) for the
selected reference cable. This property is read-only.
Data window Displays the cables that you selected in the Electrical Index, with details of the
cable tag, the cable formation, conductor material, and conductor arrangement. Beside each
cable name is a check box that allows you to select the cable for replacing.
Select all Allows you to select all the cables in the list for replacing.
648
The software replaces cables of the same category. For example, you can only replace a
power cable with another power cable.
You cannot replace a cable that has been locked to a cable drum.
The software replaces only the values of the following properties with values from the
reference cable that you select:
Cable Category
Cable Specification
Basic Ampacity in Air
Basic Ampacity in Ground
Reactance
Resistivity
Actual Conductor Size
Additional Conductor Size
Air Ampacity Temperature
Armor Type
Bending Radius
Conductor Arrangement
Conductor Material
Conductor Size
Inner Insulation Temperature
Insulation Color
Insulation Material
Insulation Temperature rating
Insulation Thickness
Insulation Voltage Rating
Jacket Color
Jacket Insulation Material
Jacket Insulation Temperature
of Additional Conductors
of Conductors
of Conductors in Group
of Sets
Outside Diameter
Overall Shield
Pull Tension
Weight per Length
Cable Formation
Electrical Equipment Class
Electrical Equipment Sub Class
Electrical Equipment Type
Stores Part Number
The software clears the values of the following properties:
Calc Starting Voltage Drop
Calc Voltage Drop Percent
The software retains the values of all other properties of the selected cables.
When the selected cables for replacing include parallel cables, only one tag per parallel cable
assembly appears in the display; however the software performs the operation for all the
parallel cables in each assembly. If descriptions exist for the individual parallel cables, the
software retains those descriptions.
If you want to replace a group of parallel cables generated by the sizing procedure with cables
having a different formation, for the Reference cable property, you must select Non-sized
power cable. Otherwise, you can only replace parallel cables with another group of cables
that have the same formation. For example, you can only replace three parallel cables of 300
m2
2
mm2 (3*300 m ) with another configuration of 3 parallel cables, such as 3*90 mm , 3*(3*25
2
2
mm +1*10 mm ), and so forth.
649
Filter criteria
Filters the Reference cable list, from which you select a reference cable. Each field for which
you select a value further filters the list.
Cable category Allows you to select a category that defines the purpose for which the cable is
used: Power, Instrumentation, Control, or Grounding. This is a required field for this dialog
box.
When defining a neutral or grounding cable for a single-core cable assembly, you can
select a power or grounding cable from the Cable category list. Power cables used as grounding
or neutral cables are automatically connected as phase cables and they appear in the Electrical
Engineer. In cable block diagrams and SLDs, the software displays them as phase power cables
belonging to single-core cable assemblies.
Cable specification Allows you to select a filter criterion that defines a family of cables, each
consisting of a specific group of reference cables.
Conductor arrangement Allows you to select a filter criterion that defines conductor number
and arrangement.
Size Allows you to select a cable size as a filter criterion.
Select cable
Reference cable Allows you to select a reference cable for the cable drum that you are
defining on the Cable Drum Common Properties dialog box. This is a required field for this
dialog box.
Cable formation Displays the cable formation (number and size of conductors) for the
selected reference cable.
Drum sizes
These options allow you to select an appropriate set of cable lengths for cable assignment to
drums.
Minimum cable length to order Displays the minimum length of cable when ordering from the
supplier. The software enters this value automatically after you select an appropriate set of cable
lengths on the Drum Sizes dialog box.
Maximum drum capacity Displays the maximum total cable length that the drum can hold,
including any spare cable. The software enters this value automatically after you select an
appropriate set of cable lengths on the Drum Sizes dialog box.
650
651
Synchronize
Allows you to select one of the options below to instruct the software to synchronize the glands on
one of the cable sides or both.
Glands on both cable sides Synchronizes the glands on both sides of the selected
cables.
Glands on the "To" cable sides Synchronizes the glands on the "To" side of the selected
cables.
Glands on the "From" cable sides Synchronizes the glands on the "From" side of the
selected cables.
Show Cable Data Populates the Cable data section with all the plant cables that comply with
filter condition that you have set and whose glands are inconsistent with the glands on the
selected reference cable.
This button becomes available only after selecting a reference cable in the Filter
criteria group box and the gland on that reference cable is inconsistent with glands on the
selected plant cables.
Cable data
This data window holds all the cables that comply with the filter criteria that you set in the Filter
cable criteria group box. Selecting the check box beside a cable includes the cable in the
synchronization process.
Select cables Allows you to select multiple cables in the Cable data section. Click the check
box to select All or click the arrow to select one of the following commands:
All Selects all the cables in the data window.
None Clears the selection of all the cables in the data window.
All cables without glands Selects all the cables that do not have any glands.
All cables with different glands Selects all the cables whose glands are different from the
ones on the associated reference cables.
652
Neutral cables
Displays the properties of the neutral cables used in the single-core cable assembly. The
properties displayed are:
Item Tag
Formation
Tag Suffix
You can click Add or Delete if you want to add or delete a cable from the current assembly.
Grounding cables
Displays the properties of the grounding cables used in the single-core cable assembly. The
properties displayed are:
Item Tag
Formation
Tag Suffix
You can click Add or Delete if you want to add or delete a cable from the current assembly.
653
Neutral cables
Allows you to select the neutral cable of the single-core cable assembly (only available if a neutral
cable has been included as part of the phase arrangement.
Click Add to open the Select Reference Cable dialog box to add the required cables.
Click Remove to remove cables that are not required.
Item tag Displays the cable name.
Category Displays the cable category.
Specification Displays the cable specifications
Formation Displays the cable formation.
Grounding cables
Allows you to select the grounding cable of the single-core cable assembly (only available if a
grounding cable has been included as part of the phase arrangement.
Click Add to open the Select Reference Cable dialog box to add the required cables.
Click Remove to remove cables that are not required.
Item tag Displays the cable name.
Category Displays the cable category.
Specification Displays the cable specifications
Formation Displays the cable formation.
654
655
If the software does not resolve all of the symbols, a message appears that instructs you to
open the log file where you can see which symbols have not been replaced.
The Resolve command button on the Resolve Symbol Inconsistencies dialog box is
available only after selecting at least one item tag to be resolved.
If a symbol cannot be resolved, the software indicates it under Expected Result. You can
click the Symbol cannot be resolved text to see the reason why the symbol cannot be
resolved.
Cable Routing
Actual Routing Path Dialog Box
The actual routing path for a cable is determined by the value of the Use External Routing
Length property. If set to True, the software displays the external routing path retrieved from
SmartPlant 3D, if it exists. If the value of the Use External Routing Length property is set to
False, this dialog box displays the routing path defined in SmartPlant Electrical, if it exists.
656
Cable routing
In this group box, you build the routing path to which you then assign cables.
Select predefined route When you click Find, allows you to select a predefined route to use
as a basis for the cable routing definition.
Copy route from cable When you click Find, allows you to select routing from another cable to
use as a basis for the cable routing definition.
Segregation level Displays the segregation level that applies for the cables that you selected
prior to opening this dialog box. The value of the segregation level is read-only.
Find Opens the Find dialog box, from which you can select as predefined route or a cable with
routing for copying, according to the option you have selected. Note that only routes or cables
that belong to the current segregation level are available for selection.
Save as New Route Opens the Route Properties dialog box, from which you can save the
current routing definition as a new predefined route.
Route details
Displays the cableways and segments that make up the routing. Note that only those segments
that belong to the current segregation level are available for selection.
Sequence Indicates the sequence of the segment in the routing path.
Cableway Select the cableway from which you want to select a segment.
Segment Select the segment through which you want to route the cables. You can use each
segment only once in a route.
Length Displays the segment length for the selected segment. You define this value in the
Properties window.
Add Adds a new segment row below the currently selected row.
Insert Adds a new segment row above the currently selected row.
Up Moves the selected row above the previous row each time that you click this option. The
order of the rows affects the order of the segments in the route.
Down Moves the selected row below the next row each time that you click this option. The
order of the rows affects the order of the segments in the route.
Remove Removes the currently selected segment from the route.
Routing length Displays the total length of the segments that you defined.
Select cables
Displays the cables that you selected in the Electrical Index or Tabular Editor, with details of the
cable tag, cable formation, cable category, armor type, and routing path. Beside each cable
name, in the Select column, is a check box that allows you to select the cable for routing.
Select all Allows you to select all the displayed cables for routing.
657
Segments
This section displays details of the segments that make up the cableway. When you start to
define the segments, the details appear. You can modify the item tag if required; all other
properties are view-only. You can also add segments to a cableway and you can delete and sort
segments that do not have cables assigned to them. Note that if you insert a segment in the
middle of a cableway that already has assigned cables, the software automatically updates the
routing.
Item Tag Allows you to modify the item tag that identifies the cableway segment.
Reference Component The reference cableway component used for the segment.
Category The category to which the segment belongs: Tray, Conduit, or Miscellaneous.
Description Displays the segment description, if applicable.
Add Adds a new segment row below the currently selected row.
Insert Adds a new segment row above the currently selected row.
Up Moves the selected row above the previous row each time that you click this option. The
order of the rows affects the order of the segments in the cableway.
Down Moves the selected row below the next row each time that you click this option. The
order of the rows affects the order of the segments in the cableway.
Remove Removes the currently selected segment from the cableway.
Notes Allows you to type user notes, for example if you want to provide additional information
regarding special features of the cableway.
658
Reference component
Describes the reference cableway component used as the catalog item for the segment. Default
values for some of the segment properties, such as Length, Width, and some fill properties come
from the component.
Find Opens the Find dialog box, where you can select a reference cableway component to
which you assign the current cableway segment.
Dissociate Allows you to clear the association of the selected reference component with the
cableway segment.
Length Allows you to type a value for the length of the segment. You can use the value that
you type to represent a space reservation or an actual length of routing.
Diameter Displays the value of the diameter of the cableway segment. This read-only value
comes from the reference cableway component used as the basis for this segment and applies
only to segments with category Conduit.
Width Displays the value of the width of the cableway segment. This read-only value comes
from the reference cableway component used as the basis for this segment and applies only to
segments with category Tray or Miscellaneous.
Depth Displays the value of the depth of the cableway segment. This read-only value comes
from the reference cableway component used as the basis for this segment and applies only to
segments with category Tray or Miscellaneous.
Notes Allows you to enter text, for example, if you want to provide additional information about
the segment.
Adjacent segments
Displays the names of the segments on either side of the current segment in the cableway. The
positions of the segments are determined by the sequence assigned to them on the Cableway
Common Properties dialog box.
From segment The segment with sequence number preceding that of the current segment. If
no segment precedes the current segment, the software displays End.
659
Segment fill
The software calculates on the fly the segment fill percentage for the cables. These cables are
routed on the segment as part of the routing, validating the segment fill percent values against the
maximum allowed values that you specify or, as defined by NEC code. The software takes into
account the fill factor that you specify and the maximum weight per unit length allowed on the
tray. If any of the actual values exceed the allowed values, the software rejects them and
displays a warning message. For area or width calculations, the software performs the validation
according to the segment category and whether or not the segment is covered. The dynamic text
that appears indicates the validation method that the software uses. Note that cable fill validation
depends on the values that exist in the Conductor Area cmils lookup table. If the value that you
require is not in this lookup table, add it manually before calculating the segment fill percentage.
Allow overfill Select this check box to ignore validation of values that exceed the allowed area
or weight.
Covered Displays whether the current cableway segment is covered or not. You cannot
change this setting because this parameter is inherited from the associated cableway component
tray in the Reference Data Explorer.
Calculation criteria Select the desired tray fill calculation (shown in percent) by Area or Width
or Auto. Select Auto if you desire the calculation by the Covered flag (default). Note that when
using NEC validation method, the Calculation criteria list is disabled.
Maximum area The maximum available area for the segment. For a covered segment, the
software calculates the area by multiplying the width and depth values together. For a conduit,
the software calculates the area from the diameter. This value is read-only, and comes from the
reference cableway component. Note that When using the NEC Validation method, the Maximum
area, Allowed area, Accumulated area and Accumulated diameter values are calculated in
inches.
Allowed area The actual maximum area of the segment that cables included in the routing are
allowed to occupy. The software calculates this value as the product of the maximum area and
the fill factor. Note that when using the NEC validation method, the Allowed area value is derived
from NEC tables according to the cable type of the cables, located in the tray. Note that when
using NEC validation method, for conduits, the Allowed area value changes according to the
number of cables in the conduit. Note that this pane will be activated only if the calculation is by
Area.
Allowed width The actual maximum width of the segment that cables included in the routing
are allowed to occupy. The software calculates this value as the product of the Maximum width of
the tray, the layers and the Fill factor, Using NEC validation method the software derives the
Allowed width from the NEC tables. Note that this pane will be activated only if the calculation is by
width.
Fill factor Type a value representing the fraction of the maximum area or the maximum width
that you want to allow when adding cables to the segment. You can type any positive value,
including values that are greater than 1; however, for conduits, covered trays or for NEC, the fill
factor value should not exceed 1.
De-rating factor Used for NEC validation, This code factor can have one of three different
values (0.4, 0.5, 0.9), The code multiplies the Allowable width or the Allowable area.
Accumulated area The total area occupied by the cables routed through the current
segment. When appropriate, the software validates this value against the allowed area value.
Note that when using the NEC validation method, the Accumulated area value may be higher
than the Allowed area value.
660
661
662
Loading parameters
Normal span The span required between two supports to ensure proper support of the
component when fully loaded.
Fill factor Type a positive value to be used as the default for segments to which you assign this
cableway component in your project. The fill factor is a quantity that the software multiplies the
maximum diameter or area of the segment by (according to the segment category) in order to
calculate the allowed area or diameter for cable fill. Note that when using the NEC validation
method, the Fill factor is limited to one.
Weight factor Type a positive value to be used as the default for segments to which you assign
this cableway component in your project. The weight factor is a quantity that the software
multiplies the maximum weight per unit length of the segment by in order to calculate the allowed
weight per unit length for cable fill.
Maximum weight per unit length Allows you to type a value for the maximum weight of cable
per unit length that the segment is capable of supporting.
Dimensions
The software uses the values you type for the dimensions to calculate the area of cableway
segments that you associate with this cableway component. If you change the value of the
dimensions after you have assigned a cable to any of these segments, the software recalculates
the segment fill parameters and accepts the change provided you do not exceed the loading
parameter values.
663
Route list
Route Displays the name of the route.
Description Displays a description for the route.
New Opens the Route Properties dialog box (on page 664) to allow you to create a new route.
Properties Opens the Route Properties dialog box to allow you to view or modify the
properties of the selected route.
Delete Deletes the selected route from the database.
664
665
Custom Folders
A compound filter consists of more than one simple filter. Simple filters are added to the
compound filter either by dragging the simple filter to the compound filter folder or by creating new
simple filters under the compound filter in the filter hierarchy. Compound filters apply only to
homogeneous item types. This dialog box specifies the properties of a compound filter, including
the name, description, and whether to match all or any of the simple filter criteria.
Name Specifies the filter name. The name can be any combination of characters and has no
length limit. Filter names within a plant must be unique. This name appears as the filter name on
the Filter Manager interface.
Description Specifies a phrase or sentence about the filter. The description can be any
combination of characters and has no length limit. The description appears as a ToolTip when you
point to the filter name on the Filter Manager interface.
Filter method
Allows you to decide whether items must meet all or only one criterion to pass through the filter.
Match all Specifies that items matching ALL of the filtering criteria pass through the filter.
Match any Specifies that items matching any one or more of the filtering criteria pass through
the filter. Match any is the default matching method.
666
Definition
Displays all defined criteria associated with a filter. To add to or modify the definition list, you must
select a line in the list and then define or edit the property in the Edit group. If you are defining the
Tabular Editor, the criteria that you enter on the Filter tab on the Advanced Table Properties
dialog box are combined with the base filter that you select.
Match all Items matching ALL of the filtering criteria pass through the filter.
Match any Items matching any one or more of the filtering criteria pass through the filter.
Match any is the default matching method.
Add Places a new entry at the end of the existing definition list. Enables the fields in the Edit
group so that you can edit the new entry.
Delete Removes the selected criterion from the definition list. This button is active only when
you select a criterion in the definition list.
Edit
Allows you to define or edit a single line of filter definition criteria.
Property Displays a list of all properties for a certain item type. Examples of properties include
Rated Power, Rated Voltage, and Frequency. You define or modify filtering criteria by selecting
a property, an operator, and a value.
Operator Specifies the relationship between the property and its value. Relationships include,
for example, greater than, >, equal to, =; not equal to, <>, and so forth.
Value Lists appropriate values for the property specified in the Property column. If a list of
properties is not already associated with the Value box, you must type a value, which can be free
text, or specify null. You can type a percent sign (%) as a wildcard character to find multiple
characters or an underscore (_) as a wildcard character for a single character. Do not use an
asterisk (*) in the Value box.
667
Electrical Equipment
Apply Options Dialog Box
Enables you to apply default profiles, circuits, control stations, schematics, and lookup tables, all
of which you define in the Reference Data Explorer, to electrical equipment. In this way, you
can create items and populate them with data in a batch operation, thus keeping to a minimum the
editing that you need to perform for individual items.
668
If you modify the components of a typical circuit that already has a reference from an item, the
software does not update the change in the reference until you next apply a typical circuit or a
profile to the item.
When an item has associated power cables, and you connect the item to a circuit by applying
a profile with a typical circuit, if there is more than one cable, the software associates the free
ends of all the power cables with the circuit.
If you apply a profile for a reference motor with a heater to a project motor without a heater, the
software adds a heater to the project motor.
If the item that you are applying a profile to is connected to a feeder circuit, the system
replaces the circuit so that it matches the applied typical circuit as specified in the profile.
If the item is connected to feeder equipment other than a circuit (such as a variable frequency
drive, a transformer, or a battery bank), the software does not apply the profile.
669
Items with the same typical circuit as the selection Updates an existing typical circuit
for the selected items.
If you apply a typical circuit to an item that is already associated with a circuit, the software
adjusts the components of the circuit to match the typical circuit specified by the item.
If you modify the components of a typical circuit that already has a reference from an item, the
software does not update the change in the reference until you next apply a typical circuit or a
profile to the item.
If the item that you are applying the typical circuit to is connected to a feeder circuit, the system
replaces the circuit so that it matches the applied typical circuit as specified in the profile.
If the item is connected to feeder equipment other than a circuit (such as a variable frequency
drive, a transformer, or a battery bank), the software does not apply the typical circuit.
If more than one item is connected to the same circuit, the software changes the last applied
typical circuit for all the items.
If you apply a typical circuit that includes associated reference cables, the software creates
project cables from them and adds the project cables to the circuit with the To sides of the
cables associated with the circuit.
You can clear the typical circuit of an item that is not connected to any circuit by selecting
Clear the last applied typical circuit.
You can apply a typical circuit on a circuit, provided that the circuit has no equipment
connected to it.
If you select a reference control station that has one or more associated control cables, the
software creates these cables in the control station that you add to the project load.
Apply to Enables you to select the rule that the software implements when associating the
control station. The options are:
All items Applies the control station to all the selected items. Select Replace control
stations to replace all existing control stations and their associated control cables; any
existing associations, such as a connection of a control cable to a junction box, are
retained. Clear Replace control stations to add the selected control stations and their
associated control cables to the selected loads along with the existing control stations.
Items with no control station Applies the control station only to items without an existing
control station. Use this option to add a control station only to new items among those items
that you have selected.
670
671
672
673
674
Bus phases
The check boxes in this group box allow you to filter the display of loads in the Associated loads
data window according to their assigned phases. You define the bus phase labels in the bus
Properties window.
Phase 1 Filters the Associated loads list and displays only the loads that are associated with
phase 1.
Phase 2 Filters the Associated loads list and displays only the loads that are associated with
phase 2.
Phase 3 Filters the Associated loads list and displays only the loads that are associated with
phase 3.
All phases Displays all the loads disregarding their phase association.
Associated loads
Displays the loads or converting electrical equipment that you added to be associated with the
current PDB and bus. Also, displays the loads or converting electrical equipment that you have
already associated with the selected power distribution board before opening this dialog
box. Note that the converting equipment associated with the current bus are shown in the
Associated loads grid if:
You have selected the Account for converting equipment power losses check box on the
Reports tab of the Preferences dialog box.
The converting equipment associated with the current bus has been defined as a load. (In this
case the associated converting equipment appears in the grid regardless of whether or not
you selected the Account for converting equipment power losses check box on the
Reports tab of the Preferences dialog box.)
675
Not applicable
Coupler circuit
Not applicable
This data window displays the key properties of the loads, including load type, consumed and
rated power, full load current, and details of their electrical connection hierarchy.
In the data window, you can assign a load to a particular phase or define it at as a multi-phase load
by selecting all three phases. Also, you can select a number of rows and move the selected loads
to cache. The moved loads then appear on the Cached Loads tab. Note that all of the values,
apart from phase assignment, in the Associated loads data window are read-only.
The software takes into account any existing equipment that is connected in
parallel.
Item Tag Displays the item tag of the selected load.
Type Displays the electrical equipment sub-class of the load, for example, motor, heater.
Consumed Active Displays the consumed kW of the selected load.
Consumed Reactive Displays the consumed kVar of the selected load.
Rated Active Displays the rated kW of the selected load.
Rated Reactive Displays the rated kVAr of the selected load.
Full Load Current Displays the full load current for the selected load.
Circuit Displays the circuit with which the load is associated.
Cell Displays the cell with which the selected load is associated.
Phase 1 Allows you to assign the selected load to phase 1.
Phase 2 Allows you to assign the selected load to phase 2.
Phase 3 Allows you to assign the selected load to phase 3.
If you want a single-phase load to simulate a two-phase load that is connected to
a three-phase bus, select two of the Phase check boxes.
Move to Cache Unassigns the currently selected loads from its associated bus and moves
them to the Cached Loads tab for reassignment. You can select multiple rows as needed.
676
Calculated Results
Converting equipment
losses
Coupler circuit
677
678
Circuits Tab
Converting equipment
losses
Not applicable
Cabinets and
instruments
Not applicable
Coupler circuit
Power distribution board Specifies the power distribution board with which you associate the
loads.
Bus Allows you to select a specific bus with which you want to associate the selected item tags.
Item Tag Displays the item tag for the circuit connected to the current bus and which feeds
other circuits.
Description Displays the circuit description.
Circuit Type Displays the circuit type, for example: Feeder, Incomer.
Rated Active Power Displays the rated kW of the circuit.
Rated Reactive Power Displays the rated kVAr of the circuit.
Rated Apparent Power Displays the rated kVA of the circuit.
679
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the battery bank, for information only.
680
681
Associated instruments
Displays a list of instruments associated with the battery bank. This information is read-only and
appears if you associated an instrument with the battery bank from the Instrument Properties
dialog box on the Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
682
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the item, for information only.
Manufacturer Allows you to select a manufacturer for the converting equipment. You can
define and customize manufacturers in the Data Dictionary Manager.
683
684
Electrical power
Entering electrical power values allows you to include these values in the calculations of load
summaries, batch load associations, and when generating enhanced all feeder load summary
reports. When performing a drill-down calculation for a PDB that has a branch connected to a
bus through a consumer converting equipment item, the software accounts for the total of this
branch using the electrical power values of this converting equipment item. Note that the
software will use these values only if the current converting equipment has been defined as a
consumer. For details, see Define Converting Equipment as Consumers (on page 104).
Rated active load Allows you to enter an appropriate rated active load value.
Rated reactive load Allows you to enter an appropriate rated reactive load value.
Rated apparent load Displays the rated apparent load value calculated by the software.
Consumed active load Allows you to enter an appropriate consumed active load value.
Consumed reactive load Allows you to enter an appropriate consumed reactive load value.
Consumed apparent load Displays the consumed apparent load value calculated by the
software.
685
686
Associated instruments
Displays a list of instruments associated with the equipment. This information is read-only and
appears if you associated an instrument with the equipment from the Instrument Properties
dialog box on the Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
I/O Type Displays the system I/O type for the instrument according to whether the signal is an
input or an output, and whether the signal type is analog or digital. This value appears if you
defined a system I/O type on the Instrument Properties dialog box.
Location
Enables you to specify the location of the feeder for the converting equipment item. Also, you can
specify these settings by performing associations in the Electrical Engineer.
687
688
Feeder equipment
Where equipment other than a PDB circuit feeds the converting equipment, the software displays
the item tag of the feeding equipment in this box. For example, if the feeder equipment is a
generator, the generator tag is displayed.
Where a feeder equipment tag appears, the properties under the Location section are
disabled. Likewise, where the feeder source is a PDB, the source data appears under the
Location section and this property is disabled.
Location
Power distribution board - Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the equipment is assigned, if defined.
Circuit Displays the circuit to which the equipment is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
689
to bring up
Very long descriptions cannot be displayed in their entirety in labels, reports, and so forth.
690
691
to open a dialog box where you can modify the item tag
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the motor, for information only. Click the
ellipsis button
to open a dialog box where you can type longer text for the description.
When typing the description in the dialog box, to begin a new line, press CTRL + ENTER.
Manufacturer Allows you to select a manufacturer for the motor. You can define and
customize manufacturers in the Data Dictionary Manager.
Model Allows you to select a motor model. The available models are specific to the
manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
Process equipment Allows you to enter a description of the equipment that the motor
drives. If the motor was retrieved from SmartPlant P&ID and included an association with an item
of process equipment, the software fills this property with the name of the process equipment.
Data quality Allows you to select a standard term that provides a qualitative measure of the
reliability of the data for this particular motor.
Conformity to standard Allows you to specify the standard for electrical calculations when
you associate a power cable with the motor. The standard affects the sizing calculation that the
software uses for an associated cable. The standard options defined in the Data Dictionary
Manager are:
National Electrical Code (NEC) The standard used in the US. When you select the NEC
standard, the software allows you to use the NEC lookup tables to automate population of
motor data in your project.
International Electrotechnical Commission (IEC) The standard used primarily in
Europe.
The conformity to standard also determines the available values of conductor size, frequency, and
rated voltage.
Motor design letter Allows you to select a design letter, which is a standard designation for
NEC motors. The design letter provides an indication of the values of various mechanical and
electrical characteristics of the motor.
Type Allows you to enter a description of the type of motor. The software uses this description
in filters and reports. You can define and customize types in the Data Dictionary Manager.
692
693
Coincidence factors
Allows you to enter values corresponding to the percentage utilization of the motor for the selected
operating mode. Also known as duty factors. Type a value between 0 and 1 for the desired
mode. A value of 0 corresponds to an unused motor, while a value of 1 corresponds to
continuous operation.
Operating mode - Select the operating mode that describes how the motor is used in practice in
the plant. The standard available operating modes are:
Continuous
Intermittent
Standby
Spare
The coincidence factor corresponding to the selected operating mode provides a
quantitative measure of the motor behavior in that mode.
Operating factor Enter a value between 0 and 1 to represent the ratio of the load power
requirement to the rated power at an operating point that you specify. The software multiplies the
consumed electrical power by the operating factor to calculate average power usage.
694
You can enter demand factor values only if it has been enabled in Data Dictionary
Manager.
For details about the various calculation modes, see Break Power / Demand Factor
Calculation (see "Brake Power / Demand Factor Calculation" on page 84).
LRC power factor Allows you to enter the value of the ratio of the active power to the apparent
power at locked rotor current (LRC). The LRC power factor can have a value between 0 and 1.
Number of wires Select the number of wires used to supply power to the motor.
Synchronous speed Displays the maximum theoretical rate of rotation of a machine shaft, in
revolutions per minute (rpm), assuming no energy losses due to the magnetic field, pole
architecture, and so forth.
Asynchronous speed Allows you to enter the actual rate of rotation of a motor shaft. If you
enter a value, it cannot be greater than the value of the synchronous speed.
Te stall time Allows you to enter the time that it takes the motor to come to rest after you switch
off the power.
Run-up time Allows you to enter the time that it takes the motor to reach its operating speed
after you switch on the power.
695
Electrical power
The software calculates the electrical power based on load data for the motor. Note that these
calculations are non-compensated. (For details about non-compensated values, see Calculating
Bus Load Summaries (on page 214).) Note that the values are all read-only.
The software can perform the calculation at three operating points:
Rated Maximum power.
Consumed Normal operation at the motor brake power.
Particular An additional point that you can specify.
Active Shows the quantity of electrical power in kW drawn from the network and supplied to the
motor that is actually converted to mechanical work.
Reactive Shows the quantity of reactive power in kVAR that the motor draws from the network.
Apparent Shows the quantity of electrical power in kVA that represents the vector sum of the
active and reactive power. This quantity is the actual power that the network needs to generate.
Average Shows the average electrical power consumption for the motor. The software uses
the average electrical power consumption to calculate overall electrical load requirements. The
software calculates the average load by multiplying the consumed active electrical power by the
operating factor that you entered on the Load Data tab.
696
697
Controller
Provides controller details in the case where there is a device that controls the motor operation.
Type of controller Describes the controller mechanism. Examples of controller mechanisms
are solid- state relay (SSR), silicon controlled rectifier (SCR), and electronic.
Variable frequency drive Select this check box if the controller is a variable-frequency drive.
Restart options
Auto restart Select the desired option to indicate whether motor restart after a power outage is
automatic or manual.
Restart group Select the group of motors to which the motor belongs when restarting. After a
power outage, the motors restart in groups, rather than all together, to avoid overloading the
network.
Associated instruments
Displays a list of instruments associated with the motor. This information is read-only and
appears if you associated an instrument with the motor from the Instrument Properties dialog
box on the Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
I/O Type Displays the system I/O type for the instrument according to whether the signal is an
input or an output, and whether the signal type is analog or digital. This value appears if you
defined a system I/O type on the Instrument Properties dialog box.
698
699
Feeder equipment
Where equipment other than a PDB circuit feeds the motor, the software displays the item tag of
the feeding equipment in this box. For example, if a Variable Frequency Drive (VFD) feeds the
motor, the VFD tag is displayed.
Where a feeder equipment tag appears, the properties under the Location section are
disabled. Likewise, where the feeder source is a PDB, the source data appears under the
Location section and this property is disabled.
Location
Power distribution board Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the motor is assigned, if defined.
Circuit Displays the circuit to which the motor is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
700
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the generator, for information only.
Manufacturer Allows you to select a manufacturer for the generator. You can define and
customize manufacturers in the Data Dictionary Manager.
Model Allows you to select a generator model. The available models are specific to the
manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
Process equipment Allows you to enter a description of the equipment that the generator
affects.
Exciter type Allows you to select the type of exciter used to establish the magnetic field in the
stator; for example, Fixed, Brushless, Static. The software uses this description in filters and
reports. You can define and customize exciter types in the Data Dictionary Manager.
Data quality Allows you to select a standard term that provides a qualitative measure of the
reliability of the data for this particular generator.
Type Allows you to enter a description of the type of generator; for example Turbo, Hydro,
Air-cooled. The software uses this description in filters and reports. You can define and
customize types in the Data Dictionary Manager.
Last applied profile Indicates the last profile that you applied to the generator, if
appropriate. This information is read-only.
701
702
703
Associated instruments
Displays a list of instruments associated with the generator. This information is read-only and
appears if you associated an instrument with the generator from the Instrument Properties
dialog box on the Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
I/O Type Displays the system I/O type for the instrument according to whether the signal is an
input or an output, and whether the signal type is analog or digital. This value appears if you
defined a system I/O type on the Instrument Properties dialog box.
704
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the instrument, for information only.
Manufacturer Allows you to select a manufacturer for the instrument. You can define and
customize manufacturers in the Data Dictionary Manager.
Model Allows you to select an instrument model. The available models are specific to the
manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
Data quality Allows you to select a standard term that provides a qualitative measure of the
reliability of the data for this particular instrument.
Type Allows you to select an instrument type such as I/P TRANSDUCER or D/P TYPE FLOW
TRANSMITTER. The available instrument types depend on the selected process function. The
software uses this value in filters and reports and when specifying data for import or export.
Process function Allows you to select a process function such as flow, level, relief valve, and
so forth.
705
706
Coincidence factors
Allows you to enter values corresponding to the percentage utilization of the associated
equipment for the selected operating mode. Also known as duty factors. Type a value between
0 and 1 for the desired mode. A value of 0 corresponds to an unused load, while a value of 1
corresponds to continuous operation.
Operating mode - Select the operating mode that describes how the associated equipment is
used in practice in the plant. The standard available operating modes are:
Continuous
Intermittent
Standby
Spare
The coincidence factor corresponding to the selected operating mode provides a
quantitative measure of the associated equipment behavior in that mode. You can customize the
available operating modes in the Data Dictionary Manager.
Associated cables
Displays the project cables that the software associates with the instrument.
(Data window) Describes the names and cable specifications of the associated cables.
Add Opens the Find dialog box, which allows you to select control, grounding, or
instrumentation cables to associate with the instrument.
You can associate more than one cable per instrument.
Remove Removes the selected associated cable from the instrument.
707
708
Location
Enables you to specify the location of the instrument feeder. Also, you can specify these settings
by performing associations in the Electrical Engineer.
Power distribution board Allows you to specify and display the power distribution board in
which the feeder is located. If you select a PDB without specifying a bus, the software assigns the
PDB to the instrument, but you can change feeder data values later if you need to.
Bus Allows you to specify and display the bus to which the instrument is assigned. The values
in this list depend on the selected power distribution board. If you select a bus without specifying
a circuit, the software assigns the bus to the instrument, but you can change feeder data values
later if you need to.
Cell Allows you to specify and display a cell/bucket/ compartment to which the instrument is
assigned. The values in this list depend on the selected bus.
Circuit Allows you to specify and display the circuit to which the instrument is assigned. If the
circuit resides in a particular cell, the values in this list depend on the selected cell. If the circuit is
linked directly to the bus, and is not linked to a cell, the values in the list depend on the selected
bus.
If you select a cell without selecting an existing circuit, the software automatically creates a
new circuit when you click Apply.
Create circuit Select to create a new feeder circuit in the bus to which the instrument is
assigned when you click Apply. The software automatically assigns the circuit name. When you
select this check box, the Create cell check box becomes active. Also, with the new circuit, if you
have specified a typical circuit for the instrument, the software assigns circuit components based
on that typical circuit.
If you do not select this check box, then unless you select a cell, the software does not
create a circuit and the instrument-bus association does not appear in the Electrical
Engineer. In this case, you can select the check box the next time you select this tab folder to
actually create the circuit.
Create cell Select to create a new cell in the bus to which the instrument is assigned. The
software automatically assigns the cell name.
Phase 1 Allows you to associate the current instrument with phase 1 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Electrical Data tab and applies only where the selected bus has an AC supply. Phase 1
refers to the label L1 or R, as defined by the value of the Phase Label1 bus property.
Phase 2 Allows you to associate the current instrument with phase 2 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Electrical Data tab and applies only where the selected bus has an AC supply. Phase 2
refers to the label L2 or S, as defined by the value of the Phase Label2 bus property.
Phase 3 Allows you to associate the current instrument with phase 3 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
709
Location
Power distribution board - Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the instrument is assigned, if defined.
Circuit Displays the circuit to which the instrument is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
710
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the metering equipment, for information only.
Manufacturer Allows you to select a manufacturer for the metering equipment. You can
define and customize manufacturers in the Data Dictionary Manager.
Model Allows you to select a metering equipment model. The available models are specific to
the manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
Type Displays the type of metering equipment, such as Potential Transformer, Ammeter, or
Multimeter. The metering equipment type determines the electrical properties that appear on
this dialog box. This value is read-only.
Data quality Allows you to select a standard term that provides a qualitative measure of the
reliability of the data for this particular metering equipment item.
Design type Allows you to select a standard that specifies the construction of the metering
equipment. You can define and customize design types in the Data Dictionary Manager.
Mounting Allows you to select a standard type of mounting as specified by the vendor for the
metering equipment. You can define and customize mountings in the Data Dictionary Manager.
Primary rating Enter the voltage applied on the primary winding. Applies to current
transformers and potential transformers only.
Secondary rating Enter the voltage output on the secondary winding. Applies to current
transformers and potential transformers only.
711
Current
Select if using the meter to measure current values.
Operating current Allows you to enter a nominal operating current for the meter, including
units. Note that the software does not validate this value against the minimum and maximum
meter ranges.
Minimum meter range Allows you to enter the minimum current that the meter is designed to
measure, including units.
Maximum meter range Allows you to enter the maximum current that the meter is designed to
measure, including units.
Voltage
Select if using the meter to measure voltage values.
Operating voltage Allows you to select a nominal operating voltage for the meter.
Minimum meter range Allows you to enter the minimum voltage that the meter is designed to
measure, including units.
Maximum meter range Allows you to enter the maximum voltage that the meter is designed to
measure, including units.
Active power
Select if using the meter to measure active power values.
Operating power Allows you to enter a nominal operating value of active power for the meter,
including units. Note that the software does not validate this value against the minimum and
maximum meter ranges.
Minimum meter range Allows you to enter the minimum active power that the meter is
designed to measure, including units.
Maximum meter range Allows you to enter the maximum active power that the meter is
designed to measure, including units.
712
Frequency
Select if using the meter to measure frequency values.
Operating frequency Allows you to select a nominal operating frequency for the meter.
Minimum meter range Allows you to enter the minimum frequency that the meter is designed
to measure, including units.
Maximum meter range Allows you to enter the maximum frequency that the meter is designed
to measure, including units.
Power factor
Select if using the meter to measure power factor values.
Operating PF Allows you to type a nominal operating power factor value for the meter.
Minimum meter range Allows you to type the minimum power factor that the meter is
designed to measure.
Maximum meter range Allows you to type the maximum power factor that the meter is
designed to measure.
Function details
After you select a reference function, this section allows you to modify the values. The software
retains any values that you modify for the specific protection relay.
Item Tag Displays the item tag of the reference item you selected on the Find dialog box. You
can click and type another item type name as needed.
713
to open a dialog box where you can modify the item tag segments that are
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
714
715
Coincidence factors
Allows you to enter values corresponding to the percentage utilization of the load for the selected
operating mode. Also known as duty factors. Type a value between 0 and 1 for the desired
mode. A value of 0 corresponds to an unused load, while a value of 1 corresponds to continuous
operation.
716
Electrical power
The software calculates the electrical power based on the load data. The values are all
read-only. The software can perform the calculation at two operating points:
Rated Maximum power.
Consumed Normal operation at the operating power.
Active Shows the quantity of electrical power in kW drawn from the network and supplied to the
load that is actually converted to output power.
Reactive Shows the quantity of reactive power in kVAR that the load draws from the network.
Apparent Shows the quantity of electrical power in kVA that represents the vector sum of the
active and reactive power. This quantity is the actual power that the network needs to generate.
Override FLA calculation Select the desired option to determine whether the software uses a
calculated or manually typed full load current value. If you select Calculated, the software
calculates the full load current value based on values you enter on the Load Data tab; the
calculated value overwrites any value that you previously entered manually. Selecting Manual
enables data entry in the Full load current box, with the last calculated full load current as the
starting value.
Full load current (FLA) The electrical current, in amperes, that the load draws from the supply
when operating at maximum power. The full load current usually appears on the nameplate of the
load. You can select Calculated or Manual from the Override FLA calculation list to determine
whether the software calculates this value or whether you enter a value manually. When the load
has an attached cable, the software copies this value to the cable and uses it as a default value for
sizing the cable.
717
Associated instruments
Displays a list of instruments associated with the equipment. This information is read-only and
appears if you associated an instrument with the equipment from the Instrument Properties
dialog box on the Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
I/O Type Displays the system I/O type for the instrument according to whether the signal is an
input or an output, and whether the signal type is analog or digital. This value appears if you
defined a system I/O type on the Instrument Properties dialog box.
718
Location
Enables you to specify the location of the load feeder. Also, you can specify these settings by
performing associations in the Electrical Engineer.
Where the feeder source is an item of equipment other than a PDB, the source tag appears
in the Feeder equipment box and all the properties in this section are disabled.
Power distribution board Allows you to specify and display the power distribution board in
which the feeder is located. If you select a PDB without specifying a bus, the software assigns the
PDB to the load, but you can change feeder data values later if you need to.
Bus Allows you to specify and display the bus to which the load is assigned. The values in this
list depend on the selected power distribution board. If you select a bus without specifying a
circuit, the software assigns the bus to the load, but you can change feeder data values later if you
need to.
Cell Allows you to specify and display a cell/bucket/ compartment to which the load is
assigned. The values in this list depend on the selected bus.
Circuit Allows you to specify and display the circuit to which the load is assigned. If the circuit
resides in a particular cell, the values in this list depend on the selected cell. If the circuit is linked
directly to the bus, and is not linked to a cell, the values in the list depend on the selected bus.
If you select a cell without selecting an existing circuit, the software automatically creates a
new circuit when you click Apply.
Create circuit Allows you to create a new feeder circuit in the bus to which the load is assigned
when you click Apply. The software automatically assigns the circuit name. When you select
this check box, the Create cell check box becomes active. Also, with the new circuit, if you have
specified a typical circuit for the load, the software assigns circuit components based on that
typical circuit.
If you do not select this check box, then unless you select a cell, the software does not
create a circuit and the load-bus association does not appear in the Electrical Engineer. In this
case, you can select the check box the next time you select this tab folder to actually create the
circuit.
Create cell Allows you to create a new cell in the bus to which the load is assigned. The
software automatically assigns the cell name.
Phase 1 Allows you to associate the current load with phase 1 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Load Data tab and applies only where the selected bus has an AC supply. Phase 1 refers to
the label L1 or R, as defined by the value of the Phase Label1 bus property.
Phase 2 Allows you to associate the current load with phase 2 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Load Data tab and applies only where the selected bus has an AC supply. Phase 2 refers to
the label L2 or S, as defined by the value of the Phase Label2 bus property.
719
Feeder equipment
Where equipment other than a PDB circuit feeds the load, the software displays the item tag of the
feeding equipment in this box. For example, if a transformer feeds the load, the transformer tag is
displayed.
Where a feeder equipment tag appears, the properties under the Location section are
disabled. Likewise, where the feeder source is a PDB, the source data appears under the
Location section and this property is disabled.
Location
Power distribution board - Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the load is assigned, if defined.
Circuit Displays the circuit to which the load is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
720
allows you to select the first equipment item in the current couple.
Item 2 Clicking
allows you to select the second equipment item in the current couple.
Input/Output Allows you to select the connection direction of the equipment: In or Out. Note
that list arrow appears only after you select a particular line.
Add Appends a new empty row to the grid, after which you can click
to find an appropriate
equipment item.
Remove Removes the selected row from the grid and after clicking Apply or OK cancels the
coupling of the items.
The software saves the changes only after you click Apply or OK.
After completing the definition of the parallel pairs and opening a cable block diagram, all the
parallel pairs become available in the Parallel pairs list on the Modify Connector ribbon.
This ribbon becomes available after clicking a cable that has been placed on a cable block
diagram. For details, see Connect Equipment Items in Parallel (on page 202).
721
to open a dialog box where you can modify the item tag
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the load, for information only.
Manufacturer Allows you to select a manufacturer for the load. You can define and customize
manufacturers in the Data Dictionary Manager.
Model Allows you to select a load model. The available models are specific to the
manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
722
723
Coincidence factors
Allows you to enter values corresponding to the percentage utilization of the load for the selected
operating mode. Also known as duty factors. Type a value between 0 and 1 for the desired
mode. A value of 0 corresponds to an unused load, while a value of 1 corresponds to continuous
operation.
Operating mode Allows you to select the operating mode that describes how the load is used
in practice in the plant. The standard available operating modes are:
Continuous
Intermittent
Standby
Spare
The coincidence factor corresponding to the selected operating mode provides a
quantitative measure of the load behavior in that mode.
724
Electrical power
The software calculates the electrical power based on the load data. Note that these calculations
are non-compensated. (For details about non-compensated values, see Calculating Bus Load
Summaries (on page 214).) Note that the values are all read-only.
The software can perform the calculation at two operating points:
Rated Maximum power.
Consumed Normal operation at the operating power.
Active Shows the quantity of electrical power in kW drawn from the network and supplied to the
load that is actually converted to output power.
Reactive Shows the quantity of reactive power in kVAR that the load draws from the network.
Apparent Shows the quantity of electrical power in kVA that represents the vector sum of the
active and reactive power. This quantity is the actual power that the network needs to generate.
For harmonic filters and capacitors, the active power is zero, therefore the reactive power
is equivalent to the apparent power.
Override FLA calculation Allows you to select the desired option to determine whether the
software uses a calculated or manually typed full load current value. If you select Calculated, the
software calculates the full load current value based on values you enter on the Load Data tab;
the calculated value overwrites any value that you previously entered manually. Selecting
Manual enables data entry in the Full load current box, with the last calculated full load current
as the starting value.
Full load current (FLA) The electrical current, in amperes, that the load draws from the supply
when operating at maximum power. The full load current usually appears on the nameplate of the
load. You can select Calculated or Manual from the Override FLA calculation list to determine
whether the software calculates this value or whether you enter a value manually. When the load
has an attached cable, the software copies this value to the cable and uses it as a default value for
sizing the cable.
725
Associated instruments
Displays a list of instruments associated with the load. This information is read-only and appears
if you associated an instrument with the load from the Instrument Properties dialog box on the
Associated Equipment tab.
Item Tag Displays the tag for the associated instrument.
Instrument Type Displays the reference instrument when you create the associated project
instrument by copying an instrument from the Reference Data Explorer. For an instrument that
you created in the Electrical Index, no value appears in this column.
Description Displays a description of the associated instrument.
I/O Type Displays the system I/O type for the instrument according to whether the signal is an
input or an output, and whether the signal type is analog or digital. This value appears if you
defined a system I/O type on the Instrument Properties dialog box.
726
Location
Enables you to specify the location of the load feeder. Also, you can specify these settings by
performing associations in the Electrical Engineer.
Where the feeder source is an item of equipment other than a PDB, the source tag appears
in the Feeder equipment box and all the properties in this section are disabled.
Power distribution board Allows you to specify and display the power distribution board in
which the feeder is located. If you select a PDB without specifying a bus, the software assigns the
PDB to the load, but you can change feeder data values later if you need to.
Bus Allows you to specify and display the bus to which the load is assigned. The values in this
list depend on the selected power distribution board. If you select a bus without specifying a
circuit, the software assigns the bus to the load, but you can change feeder data values later if you
need to.
Cell Allows you to specify and display a cell/bucket/ compartment to which the load is
assigned. The values in this list depend on the selected bus.
Circuit Allows you to specify and display the circuit to which the load is assigned. If the circuit
resides in a particular cell, the values in this list depend on the selected cell. If the circuit is linked
directly to the bus, and is not linked to a cell, the values in the list depend on the selected bus.
If you select a cell without selecting an existing circuit, the software automatically
creates a new circuit when you click Apply.
Create circuit Creates a new feeder circuit in the bus to which the load is assigned when you
click Apply. The software automatically assigns the circuit name. When you select this check
box, the Create cell check box becomes active. Also, with the new circuit, if you have specified a
typical circuit for the load, the software assigns circuit components based on that typical circuit.
If you do not select this check box, then unless you select a cell, the software does not
create a circuit and the load-bus association does not appear in the Electrical Engineer. In
this case, you can select the check box the next time you select this tab folder to actually
create the circuit.
Create cell Creates a new cell in the bus to which the load is assigned. The software
automatically assigns the cell name.
Phase 1 Allows you to associate the current load with phase 1 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Load Data tab and applies only where the selected bus has an AC supply. Phase 1 refers to
the label L1 or R, as defined by the value of the Phase Label1 bus property.
Phase 2 Allows you to associate the current load with phase 2 of the selected bus. The
availability of this option depends on the value you selected from the Number of phases list on
the Load Data tab and applies only where the selected bus has an AC supply. Phase 2 refers to
the label L2 or S, as defined by the value of the Phase Label2 bus property.
727
Feeder equipment
Where equipment other than a PDB circuit feeds the load, the software displays the item tag of the
feeding equipment in this box. For example, if a transformer feeds the load, the transformer tag is
displayed.
Where a feeder equipment tag appears, the properties under the Location section are
disabled. Likewise, where the feeder source is a PDB, the source data appears under the
Location section and this property is disabled.
Location
Power distribution board Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the load is assigned, if defined.
Circuit Displays the circuit to which the load is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
728
Tapping options
Tapping required Allows you to enable the tapping options.
Tapping Allows to select a tapping option. The options are for information only and do not
affect the ability to enter data values for the other properties in this section.
Tapping percentage per step Allows to type the percentage of the total winding length to be
used for each step interval for tapping.
Number of steps Allows to type the total number of tapping points required along the winding.
Total tapping percentage range The calculated value of the product of the tapping
percentage per step and the number of steps.
729
730
External Documents
Associate Documents Dialog Box
Enables you to associate documents with selected electrical items. Also, you can open the
associated documents for editing, and you can dissociate a document if needed. An asterisk
beside a property name indicates required data.
The dialog box opens when you select an electrical item and then click Actions > Associate
Documents.
The options are as follows:
Filter by
Allows you to select a set of criteria to filter the documents that you associate with selected
electrical items.
Document category Filters the documents according to document category. This selection
determines the available options in the Document type list. You can define and customize
document categories in the Data Dictionary Manager.
Document type Filters the document category according to document type. This selection
determines the documents that the software retrieves after you click Find in the Edit group.
Selecting All types filters the documents according to category only. You can define and
customize document types in the Data Dictionary Manager.
List
Displays all the documents associated with the selected electrical items.
Add Opens the Find dialog box that allows you to find a document that you want to associate
with the current electrical item.
731
Properties
Displays the properties of a document that you select under List.
Document Displays the name of the selected document. The value for this property appears
after you click Find and select the document reference on the Find dialog box. The Find dialog
box retrieves all the existing document references and documents belonging to the selected
document category and type.
Document type Displays the type of the selected document.
Description Displays the description of a selected document.
Path and file name Displays the name and the file path of the selected external file.
Filter by
Includes the set of criteria to filter the external documents that you associate with selected
electrical items.
Document category Filters the external documents according to document category. This
selection determines the external document references that the software retrieves after clicking
the ellipsis button
in the Edit group beside Path and file name. You can define and
customize document categories in the Data Dictionary Manager.
Document type Filters the external document category according to document type. This
selection determines the external documents that the software retrieves after clicking the ellipsis
button
in the Edit group beside Path and file name. Selecting All types causes the software
to filter the documents according to category only. You can define and customize document
categories in the Data Dictionary Manager.
List
Displays all the documents associated with the selected electrical items.
Open Opens the document that you have selected under List.
Remove Removes the document that you have selected under List.
Add Appends a new document row with information about a document you are about to
associate.
Properties
Allows you to edit the properties of a document that you select under List.
Document Allows you to type the name of the selected external document.
Document type Allows you to select the type of the selected external document.
Description Allows you to type the description of a selected external document.
Path and file name Displays the name and the file path of the selected external file. To
navigate to the file name and path, click the ellipsis button
732
Interfaces
Retrieve Document Dialog Box
Source XML folder allows you to type the path to the source folder containing the .xml files
associated with the document that you want to retrieve, or click Browse to navigate to the desired
location.
Document Allows you to select from the list the document that you want to retrieve.
OK Retrieves the selected document and closes the dialog box.
Save options
Save files Saves the selected drawings as external files.
Path Allows you to type the file path or click Browse to navigate to the folder where you want to
save the drawings. The software automatically displays the default path that you have set for
your drawings in the Options Manager.
Save as type Allows you to select a file format for the drawings you want to save.
Print drawings Prints out all the drawings that you are comparing.
Print comparison reports Prints a comparison report for each selected document.
Revisions
Select a revision to compare with the current version.
Archived A check mark in this box indicates that the software archived a copy of the pertinent
document revision.
Revision Number Displays the revision number that complies with the selected revision
method. After clicking New, the software increments the last revision by one or use the next letter
in the alphabet. Also, the software allows you to type an appropriate revision number if you
choose not to accept the displayed value.
Revision Date The date when you made the revision.
Created by The name or the initials of the person who made the revision.
733
734
735
Revisions
Archived A check mark in this box indicates that the software archived a copy of the pertinent
document revision.
Revision Number Displays the revision number that complies with the selected revision
method. After clicking New, the software increments the last revision by one or use the next letter
in the alphabet. Also, the software allows you to type an appropriate revision number if you
choose not to accept the displayed value.
If you type a value that does not comply with the current revision method, the next time you
add a new revision, the software starts a new numbering. For example, the selected revision
method is P0, P1, P2 and the last revision is P3. If you add a new revision number RRR and
then another one using the P0, P1, P2 method, the software displays the newly added revision
as P0.
If you type a value that complies with the numbering method but the value you is not
sequential, the software increments the number of the next revision that you add. For
example, the selected revision method is P0, P1, P2 and the last revision is P3. If you add a
new revision number P1, the software increments the following revision to P2.
Revision Date The date and time of the revision.
Created by The name or the initials of the person who made the revision.
Checked by The name or the initials of the person who checked the revision.
Approved by The name or the initials of the person who approved the revision.
Description Allows you to type a brief revision description.
Revision Name The name of the revision or other identifying text. You can overwrite this text
if desired.
View Allows you to open a selected archived version of the document. The software opens
archived documents in view mode only.
736
737
738
739
740
To avoid loss of precision in units when switching between small and large types of a particular
unit, increase the precision, that is, increase decimal places, of the larger unit through Format
Manager.
All delivered labels use plant default units, which are defined in the Options Manager, and so
labels do not always display the units selected in the Properties window. Change the Unit
definition in the SmartText Editor dialog box in Catalog Manager to see a different unit of
measure in a label.
The software supports round-trip conversion of units without loss of precision. That is, you can
convert centimeters to meters and back and retain the originally entered value of centimeters
with no round-off loss.
Settings
Revision number Allows you to type an appropriate revision number to be used when adding
or updating revisions. This setting is not available when upgrading revisions.
Revision date Allows you to enter the revision date.
Created by Allows you to type the name or the initials of the person who made the revision.
741
742
Panels
Cabinet Common Properties Dialog Box
Sets options for defining the general properties of wiring cabinets. Also, this dialog box defines
properties that the software uses for calculating electrical loads and associating the item with the
electrical supply.
General Tab (see "General Tab (Cabinet Common Properties Dialog Box)" on page 743)
Electrical Data Tab (see "Electrical Data Tab (Cabinet Common Properties Dialog Box)" on page
744)
Feeder Data Tab (see "Feeder Data Tab (Cabinet Common Properties Dialog Box)" on page 745)
Alternative Feeder Tab (see "Alternative Feeder Tab (Cabinet Common Properties Dialog Box)"
on page 746)
to open a dialog box where you can modify the item tag
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option that you set in Options Manager.
Description Allows you to type a description of the cabinet, for information only.
Manufacturer Allows you to select a manufacturer for the cabinet. You can define and
customize manufacturers in the Data Dictionary Manager.
Model Allows you to select a cabinet model. The available models are specific to the
manufacturer. You can select a model without selecting a manufacturer. The software then
selects the appropriate manufacturer automatically according to the selected model. You can
define and customize models in the Data Dictionary Manager.
Type Displays the type of cabinet. You can define and customize cabinet types in the Data
Dictionary Manager. The software uses this description in filters and reports.
Data quality Allows you to select a standard term that provides a qualitative measure of the
reliability of the data for this particular cabinet. For example, Preliminary, Certified, or As Built.
Notes Allows you to enter text, for example, if you want to provide additional information about
the cabinet.
743
744
Location
Enables you to specify the location of the cabinet feeder. Also, you can specify these settings by
performing associations in the Electrical Engineer.
Where the feeder source is an item of equipment other than a PDB, the source tag appears
in the Feeder equipment box and all the properties in this section are disabled.
Power distribution board Allows you to specify and display the power distribution board in
which the feeder is located. If you select a PDB without specifying a bus, the software assigns the
PDB to the cabinet, but you can change feeder data values later if you need to.
Bus Allows you to specify and display the bus to which the cabinet is assigned. The values in
this list depend on the selected PDB number. If you select a bus without specifying a circuit, the
software assigns the bus to the cabinet, but you can change feeder data values later if you need
to.
Cell Allows you to specify and display a cell/bucket/ compartment to which the cabinet is
assigned. The values in this list depend on the selected bus.
Circuit Allows you to specify and display the circuit to which the cabinet is assigned. If the
circuit resides in a particular cell, the values in this list depend on the selected cell. If the circuit is
linked directly to the bus, and is not linked to a cell, the values in the list depend on the selected
bus.
If you select a cell without selecting an existing circuit, the software automatically creates a
new circuit when you click Apply.
Create circuit Allows you to create a new feeder circuit in the bus to which the cabinet is
assigned when you click Apply. The software automatically assigns the circuit name. When you
select this check box, the Create cell check box becomes active. Also, with the new circuit, if you
745
Location
Power distribution board Displays the power distribution board in which the feeder is located.
Bus Displays the bus belonging to the power distribution board.
Cell Displays a cell/bucket/ compartment to which the cabinet is assigned, if defined.
Circuit Displays the circuit to which the cabinet is assigned.
Feeder equipment Displays the item used as the alternative supply (generator, battery bank,
off-site power and so forth).
746
Associated cables
Displays the project cables that the software associates with the control station.
(Data window) Describes the names and cable specifications of the associated cables.
Add Opens the Find dialog box, which allows you to select control, grounding, or
instrumentation cables to associate with the control station.
You can associate more than one cable per control station.
Remove Removes the selected associated cable from the control station.
747
Project Management
Project Management Table (As-Built)
The Project Management table in As-Built allows you to select a target project and to scope items
for that project, and to merge items in the project back to As-Built after you have edited or created
them in the project. The commands associated with the Project Management table are all on
the Project Management toolbar (on page 749). This table opens when you click Window > New
> Project Management on the main menu bar.
748
Header
Description
(Check box)
The tag of the main item. A main item can be a motor or some
other load, converting equipment, a power source, any free cable,
a PDB, or a document.
The tag of the related item which has an electrical association with
the main item; for example, if the main item is a motor, related
items can include cables, signals, control stations, and circuits.
Item Type
Status in project
Claim Mode
New Item
Item Path
Description
Plant Group
Deleted
Indicates whether the item has been deleted in the project since
the last time it was scoped.
Result Status
Command
Explanation
Select Project
Project Status
Add Items
Scope
Test Merge
Merge
Find Completed
Items
Opens the Find dialog box, which allows you to find all the
completed items in the project. You can select all or some of
the completed items and then merge them into As-Built.
749
Command
Explanation
Show Merged
Items
Filters the display to show only those items that have been
merged back into As-Built. Note that the filter relates to the
status of the items in the database and not necessarily the
status currently displayed in the Project Management
table.
Show Claimed
Items
Filters the display to show only those items that have been
claimed for the project. Note that the filter relates to the
status of the items in the database and not necessarily the
status currently displayed in the Project Management
table.
Show Items
Deleted from AsBuilt
Filters the display to show only those items that have been
deleted in As-Built. Note that the filter relates to the status
of the items in the database and not necessarily the status
currently displayed in the Project Management table.
Show Item
Properties
Clear All
Clear
Show / Hide
Buffer
Paste from Buffer Pastes to the Project Management table items from the
buffer whose check boxes are selected.
750
Excel Report
Display
Command
Explanation
Compare
Documents
Description
(Check box)
The tag of the main item. A main item can be a motor or some
other load, a PDB, a cable.
Item Type
Status in project
Claim Mode
New Item
Item Path
Description
751
Description
Plant Group
Result Status
When merging an item that is connected in parallel with another equipment item, the
software automatically merges all the items that are connected in parallel to the scoped item. For
example, if you select Motor-1 that has been connected in parallel with Motor-2 and Motor-3, the
software will also automatically merge Motor-2 and Motor-3 and their upstream items all the way
to their power sources.
Command
Explanation
Project
Management
Add Items
Apply
Mark as Reclaimed Marks an item with status Merged for claiming again in
the project, if the check box beside the item is
selected. After clicking Apply, the status of the item
changes to Claimed.
752
Mark as
Completed
Clear Mark as
Completed
Command
Explanation
Release Claim
Release from
Merge
Test Merge
Publish After
Merge
Find Completed
Items
Opens the Find dialog box, which allows you to find all
the completed items in the project. You can select all or
some of the completed items and then merge them into
As-Built.
Show Merged
Items
Show Claimed
Items
Show Items
Deleted from
Project
753
Command
Explanation
Show Item
Properties
Select Related
Items
Allows you to select all related items for which the main
item is already selected for the next action that you
want to perform. A sub-menu option also allows you to
clear the selection of all related items.
Clear All
Clear
Excel Report
Display
You can change the status of a SmartPlant Electrical project only from a project. If you open
the Project Status dialog box in As-Built, the project status is view-only and it cannot be
changed.
You cannot claim items in a project whose status has been set to Completed or Merged.
SmartPlant project status Displays information about the status of the active project with
respect to SmartPlant Foundation. This area is not active if the plant is not registered with
SmartPlant Foundation.
Refresh Status Searches for and displays the status of this project in SmartPlant Foundation
and updates this information in SmartPlant Foundation if appropriate. This button is not available
if the plant is not registered with SmartPlant Foundation.
754
755
to open a dialog box where you can modify the item tag segments that are editable.
The tag property Comply with Naming Convention determines the behavior of an item
tag name. When the property is set to True, the protection masks and segment properties
behave according to the settings for the item naming convention in the Options Manager. When
the property is set to False, you can edit the tag name value freely. Whether you set this property
to True or False, the software ensures compliance with uniqueness if you set the Is Unique
parameter to True in the Item Type Properties option of the Options Manager.
Description Allows you to type a description of the circuit, for information only.
Circuit mode Indicates whether the circuit is connected or disconnected. When you
designate the circuit as Connected, the software includes in power calculations any loads that are
associated with the circuit. The results of these calculations appear on the Batch Load
Association dialog box and in various shipped load summary reports.
Circuit type Describes the type of circuit: incomer, feeder, coupler, or bus riser.
Last applied typical circuit Indicates the last typical circuit that you applied to the circuit, if
appropriate. This information is read-only.
Last applied typical schematic - Indicates the last typical schematic that you applied to the
circuit, if appropriate. This information is read-only.
Last applied typical I/O set Indicates the last typical I/O set of signals that you applied to the
circuit, if appropriate. This information is read-only and only appears if you apply a typical I/O set
by dragging it from the Reference Data Explorer or by applying options to the circuit.
Notes Allows you to enter text, for example, if you want to provide additional information about
the circuit.
756
Location
Specifies the location of the circuit in the electrical network.
Power distribution board - Indicates the power distribution board in which the circuit is located.
Bus Indicates the bus on which the circuit is located.
Cell Indicates the cell/bucket/compartment on which the circuit is located, if applicable.
Associated loads
Displays the list of loads that are associated with the circuit. It is possible to display only those
loads that are associated directly with the current circuit (this is the default option) or all the loads
associated downstream with the current circuit.
Item Tag Displays the item tag for the associated load.
Type Displays the electrical equipment item type of the associated load, for example, motor,
heater.
Show only loads associated directly Displays in the Associated loads box only those loads
that are connected directly to the current circuit. (This is the default setting.)
Show all loads associated downstream Displays in the Associated loads box all the loads
that are connected downstream to the current circuit. Note that the application resets the selection
to the default option after reopening this dialog box.
After selecting this option, the software retrieves all the downstream loads that
are associated with the current circuit. If this electrical network branch is long, it can take a
long time to retrieve all the data.
Circuit signals
Describes all the signals that are associated with the circuit.
Item Tag Displays the signal tag for the associated circuit signal.
Equipment Type Displays the equipment type of the item that the signal originates from.
Description Displays a description of the associated I/O signal.
757
Associated cables
Describes all the cables that are associated with the circuit.
Reference Cable Displays the reference cable for the cable associated with the circuit.
Specification Indicates the family of cables to which the cable belongs.
Cable Formation Displays the cable formation (number and size of conductors) for the cable.
Circuit internals
Displays details of the components in the selected circuit. The values are read-only.
To update the circuit components, you need to modify the selected circuit in the Electrical
Index. For more information, refer to Related Topics.
Component Type Displays the type of component in the circuit, such as a circuit breaker or a
fuse.
Component Tag Displays the component identifying tag, as shown in the Electrical Index.
Lookup Table Allows you to select a lookup table that you want to associate with an internal
component of a circuit. You will then be able to apply this associated lookup table to a project
circuit when you run the Apply Lookup Tables feature on the Apply Options dialog box to
propagate the lookup table data to the circuit internal components.
Order Determines the position of the component in relation to the bus when the circuit contains
more than one component. The greater the value, the further the component is from the bus.
Show in SLD Indicates whether the software shows a graphical representation of the
component when you generate a single line diagram for the PDB.
Add Opens the Add Internal Item dialog box to enable you to add new internal components for
the circuit.
Move Out Allows you to move a circuit internal out of the circuit and place it under the circuit in
the Electrical Engineer as stand-alone disconnect equipment. It is only possible to move out an
internal whose Order value in the Circuit internals pane is 1.
Remove Removes the currently selected component from the circuit.
758
One unit of measure represents the width or height of a standard cell. You can make the size
of a cell as big as needed as long as the cell is within the limits of the defined PDB
cabinet. Also, you can define a cell to have a fraction of a cell size. For example, enter 0.5
for half the cell width or height.
When decreasing the size of a compartment, the maximum number of compartments that a
vertical section or a horizontal row can have depends on the value that you enter for the
Compartments in Row and Compartments in Section properties in the Properties window
for the power distribution board to which the cell belongs.
When increasing the size of a compartment, the software enlarges the compartment only to its
right or down.
When increasing the size of a compartment, the software checks if the adjacent cells that are
under and to the right of the current cell can accommodate the new cell size. Note that you
have to divide the adjacent compartment to prepare it for the new increased cell.
You cannot exceed the boundaries of a vertical section. You can only increase the number of
compartments within the boundaries of a vertical section. You can increase the height of a
compartment. In this case, the compartment will occupy the full size of the compartment
located directly below it.
The software resizes the compartments with the upper left corner of the compartment as its
point of origin.
You cannot resize a compartment if its new size infringes on an adjacent compartment that is
occupied by another cell.
General definitions
These settings allow you to define the height and width of the grid units that make up the PDB
layout drawing. The width of the vertical sections and the height of the grid rows are measured in
these units. Also, you can define the current PDB as double-sided.
Item tag Displays the name of the power distribution board for which you are designing this
structure.
Double-sided PDB Allows you to set the current PDB as double-sided. This will enable you to
define a section side as front or rear.
Grid unit height Allows you to define the height of the grid units in the PDB layout
drawing. This setting determines the height of the grid rows.
Grid unit width Allows you to define the width of the grid units in the PDB layout drawing. This
setting affects the width of the vertical sections.
759
Grid rows
Allows you to define the vertical structure of the current PDB. That is, you define the number of
rows that will make up the height of the current PDB.
Number of rows Allows you to enter the number of rows that will comprise the layout of the
current PDB. You can add more rows at the top of the list if you click Add.
Row naming type Allows you to automatically name the rows according to the type that you
select. The options are:
Free text Allows you to type any alpha-numeric characters that you need. This is the
default setting. Note that if you already have names for your rows, changing this setting to
Free text removes all the names that were displayed before.
A.B.C. Names the rows as A, B, C, and so on.
1,2,3 Names the rows as 1, 2, 3, and so on.
Vertical Position Displays the vertical sequence numbers of the grid rows. Note that the top
of the list always shows the lowest row in the PDB.
Row Displays the row names. Also allows you to type a name as you require, which overrides
the automatic naming.
Add Allows you to add another row to the top of the list. Note that the software names the
added row according to the selected naming type. You can click in the required row name and
over type the name as you need.
Delete Allows you to delete a row from the top of the list. You can select and delete several
consecutive rows from the top of the list. Note that the software does not allow you to delete a
row that is already assigned to a cell. Remove the assigned cell from the PDB layout before
deleting the redundant row.
Command Buttons
Apply After changing the data, refreshes the display of data in the dialog box.
760
761
Text
Caption Type the text that you want to appear in the in the annotation box.
Watermark
Set as watermark Select the box if you want to use the text as a watermark, which means that
it appears behind other drawing items. This option is not available when editing an annotation.
Annotation locking
Lock to item tag Select the box to lock the position of the annotation text to the selected item
tag. In this case, when moving the item tag, the attached annotation moves with it.
Move independently Select this option to be able to move the annotation text independently
from the item tag that it is locked to. For this option, the software keeps the annotation text locked
to the item tag, but allows you to move the annotation text too.
762
Style
The preview window displays the appearance of the selected font.
Font Click to open the standard Windows Font dialog box to define the font, font style, size,
color, and other properties.
Border
Show Border Select this option to display a border around the text.
Text alignment
Horizontal Select the horizontal alignment of the text: left, center, or right.
Vertical Select the vertical alignment of the text: top, center, bottom, or justified.
Placement
Rotation Type the rotation angle of the text in degrees. You can enter positive values from 0
to 360 degrees, or negative values to 180 degrees. The text rotates counter-clockwise when you
type a negative value.
Orientation Select the orientation of the text inside the text box: horizontal or vertical.
Reference Items
Associate Reference Cable Dialog Box
Enables you to select an existing reference cable or specify a new reference cable to associate
with a control station or an item profile.
Cable specification Allows you to select an appropriate cable specification. You must select
a cable specification before you can select a cable.
Cable definition
Select from cable library Choose this option to select an existing reference cable.
Reference cable Indicates the selected reference cable for associating with the control station
or profile.
Select Opens the Reference Cable Library window, which shows the cables that belong to
the cable specification that you selected.
Specify construction Select this option to define a new reference cable based on a specified
conductor arrangement. This option is available only when you define a reference cable for an
item profile and a reference circuit.
763
764
765
766
Each time you define a row of data, the software adds a new blank row automatically at the
end of the list. To define more than 17 rows, you have to do one of the following: increase the
window size, maximize the window, close the window and then re-open it, or press the 'down
arrow' key on the keyboard.
Each combination of data in the key fields must be unique. The software indicates key fields
by double sets of asterisks (**) in the header labels. For more details, see Lookup Table Data
Example (on page 58).
767
Edit
Provides options for you to select a property and specify how it behaves when you apply the
lookup table.
Item type Displays the item type for which the lookup table applies. The value is read-only,
except in the case of transformers, where you can select whether to show the properties of the
primary winding or of a secondary winding.
Property Allows you to select a property for use in the lookup table. In the case of a lookup
table for a transformer, the Number of Secondaries property appears by default and you cannot
delete it.
Caption Allows you to type any text to use as the caption for the property. The caption
appears in the header row on the Data tab.
768
769
770
771
Drum definition
Allows you to define cable drum parameters that are used to assign project cables to drums. Once
you assign a reference cable to a particular drum, the software uses these values for manual and
automatic cable assignment to drums.
When assigning cables to drums manually, you associate a drum with a specific reference cable.
You can define multiple drum sizes for each reference cable. These drum sizes are based on
various cable lengths that a drum can hold. Once you associate a drum with a reference cable that
has multiple drum sizes, you can select the most appropriate drum size for a particular drum.
When assigning project cables to drums automatically, the software optimizes the cable
assignment. SmartPlant Electrical optimizes this assignment based on the drum sizes, the
maximum percentage of free cable length on the drums and the scrap cable length that you have
defined for each reference cable that you select for drum assignment. For more details, see
Optimization of Cable Drum Assignment.
You perform automatic cable assignment by using the Assign Drums to Cables wizard. When
using the wizard, you define the assignment parameters by selecting the following:
All the available reference cables or just one specific reference cable.
One or more pulling area.
The wizard will then assign all the project cables that comply with these parameters. Furthermore,
the software will optimize cable assignment to the drums based on the drum sizes, the maximum
percentage of free cable lengths on the drums, and the scrap cable length that you have defined
for each reference cable that you selected in the wizard.
Drum sizes Allows you to define multiple sets of cable lengths that will be used in cable drum
assignment. Note that all the values that you enter in this grid become available on the Drum
Sizes dialog box when setting a reference cable for a cable drum.
Minimum Allows you to type a value and select an appropriate unit of measure for the
minimum length of cable when ordering from a supplier.
Maximum Allows you to type a value and select an appropriate unit of measure for the
maximum drum capacity. This value is the total cable length that a drum can hold, including
any spare cable.
Remove Deletes a row that you select.
Maximum free length on drum (%) Allows you to type a value which sets the maximum
percentage of free space that can be left on a drum. A drum that has more free space than the
value you set here makes the drum not optimized. Note that this option is applicable to automatic
cable assignment only. The software indicates if a drum is not optimized in the cable drum log file.
Scrap cable length Allows you to specify the scrap length for the cables that are based on the
current reference cable. The software will use this value when calculating the total cable length on
a drum in your project. Note this value has no effect on any other calculations.
772
Design data
Provides information about the physical characteristics of the cable.
Use external routing length This information only applies to project cables.
Estimated length Allows you to enter the estimated length of cable before installation for use
as a default value in project cables.
Design length Allows you to enter a more accurate length for the cable after installation for use
as a default value in project cables.
Routing length This information only applies to project cables.
External routing length This information only applies to project cables.
Tail 1 Type a value for the spare tail length at one end the cable, if you require, for use as a
default value in project cables.
Length A calculated field that displays the design length, or if not available, the estimated
length.
Tail 2 Type a value for the spare tail length at the other end the cable, if you require, for use as
a default value in project cables.
Spare length Type a value for additional spare cable length, if you require, for use as a default
value in project cables.
Actual length This information only applies to project cables.
773
Associated cables
Displays the reference cables that the software associates with the control station.
(Data window) Describes the properties of the associated cables. In particular, this window
shows the conductor arrangement.
Add Opens the Select Reference Cable dialog box to associate a new reference cable with
the control station.
Remove Removes the selected associated cable from the control station.
Sheets
Sheet Number Displays the sheet number that you typed under Sheet number in the Sheet
details group box.
Sheet Name Displays the sheet name that you typed under Sheet name in the Sheet details
group box.
Add Adds a new row to allow you to define a new sheet.
Remove Removes a selected sheet from the list. The software deletes the removed sheet
from the database after you click OK.
Sheet details
Sheet number Allows you to type a sheet sequence number for a sheet selected in the Sheets
list. You will then be able to select this sheet number and assign it to a block when editing the
properties of that typical schematic drawing.
Sheet name Allows you to type a sheet name for a sheet selected in the Sheets list.
774
Cable definition
Select from cable library Allows you to select a reference cable by choosing an existing
reference cable.
Reference cable Click Select and then select an appropriate cable from the cable library.
Specify construction Allows you to associate a new plant cable which you create based on
the construction definitions below.
Conductor arrangement Allows you to define the number and arrangement of the conductors
in the cable. The following standard options are available:
Single core cable Creates a current-carrying cable with a single core. For this option, you
can specify an arrangement of any number of single-core conductors, for example, 3
single-core cables, but you cannot specify any additional conductors.
2-core cable Creates a cable with two current-carrying conductors and no additional
conductors. You cannot modify the cable construction for this option.
2+1-core cable Creates a cable with two current-carrying conductors and one additional
conductor. You cannot modify the cable construction for this option.
3-core cable Creates a cable with three current-carrying conductors and no additional
conductors. You cannot modify the cable construction for this option.
3+1-core cable Creates a cable with three current-carrying conductors and one additional
conductor. You cannot modify the cable construction for this option.
3+2-core cable Creates a cable with three current-carrying conductors and two additional
conductors. You cannot modify the cable construction for this option.
Multicore cable Creates a cable with multiple conductors. For this option, you can specify
any number of conductors and additional conductors.
You can change the names of the standard conductor arrangement items in the Data
Dictionary Manager. However, the software performs calculations according to the position in the
list of the item that you select. For example, a 2-core cable is always the second item in the list.
Conductors Allows you to specify the number of conductors within the cable used for carrying
the current, excluding the neutral, the ground, or additional conductors. If you selected Singlecore or Multicore as the conductor arrangement, this option allows you to specify the number of
conductors or cores in the cable that carry the electric current.
Additional conductors If you selected Multicore as the conductor arrangement, allows you to
specify the number of additional non-current-carrying conductors, such as ground wires.
775
Associated cables
Displays the reference cables that the software associates with the typical circuit.
(Data window) Describes the properties of the associated cables. In particular, this window
shows the conductor arrangement.
Add Opens the Select Reference Cable dialog box to associate a new reference cable with
the typical circuit.
Remove Removes the selected associated cable from the typical circuit.
776
to navigate to the
You can only select drawing files from the default folder specified in the Options Manager; you
cannot navigate to files in any other folder.
You can click View to preview the currently selected block before selecting it.
777
You can click View to preview the currently selected block before adding it to the typical
schematic.
This option is not available for multi-tag blocks.
Sheet number Allows you to assign a sheet number to the current block in the typical
schematic you are modifying or creating. The values in this list correspond to the sheets that you
create in the Schematic Sheet Properties dialog box. You can assign the same block to several
different sheets if you want the block to appear more than once on different sheets of the same
schematic. Note that you should assign a sheet to each block in the typical
schematic. Unassigned sheets are not kept in the database by the software. This option is not
available or multi-tag blocks.
X Allows you to enter a positive or negative numeric value in the CAD application units of
measure for the X-coordinate. In the generated schematic drawing, the software will shift the
relevant block on the X (vertical) axis according to the value you enter.
Y Allows you to enter a positive or negative numeric value in the CAD application units of
measure for the Y-coordinate. In the generated schematic drawing, the software will shift the
relevant block on the Y (horizontal) axis according to the value you enter.
Multi-Tag Options Opens the Multi-Tag Schematic Options dialog box where you can
specify whether to include a tag list on the main drawing page of a multi-item schematic, and the
maximum number of rows in the list to allow on the drawing sheets. This option is available when
you select a multi-tag block.
778
779
780
781
782
783
When sorted in ascending or descending order, the properties that have sub-properties
appear first sorted alphabetically, followed by the properties that do not have sub-properties,
sorted alphabetically.
For a summary report, the list entry Report Item Group Total that appears at the lowest level
is always at the bottom of the list, regardless of the sort order selected.
784
Schematics
Batch Generate Schematics Dialog Box
Allows you to print and set save options for the schematics you generate in batch mode.
Save options
Save files Saves the generated drawings as external files.
Path Allows you to type the file path or click Browse to navigate to the folder where you want to
save the drawings. The software automatically displays the default path that you have set for
your drawings in the Options Manager.
Save as type Allows you to select a file format for the drawings you want to save.
Print drawings Prints out all the drawings that you are generating.
785
Data window
Block Type Displays the block type (motor, circuit, or control station) of the selected block.
Item Name Displays the name of the electrical item with which the block is associated. You
can change this association in the Block details group box.
Block Name Displays the name of the typical block.
X Displays the X block displacement coordinate from the page origin. The software takes this
value from the properties of the associated typical schematic.
Y Displays the Y block displacement coordinate from the page origin. The software takes this
value from the properties of the associated typical schematic.
File Name Displays the name of the graphic file that the typical block is associated with.
Block details
Block type Displays the block type that the selected typical block belongs to.
Item name Displays the electrical item that the selected typical block is associated
with. Select another electrical item if you want to change this association.
Block name Displays the name of the selected typical block.
Sheet number Displays the sheet number that is assigned to the selected typical block. The
software displays a sheet number only if the selected typical schematic contains multiple sheets.
786
Data window
Item Name Displays the name of the electrical item that the selected macro is associated with.
Macro Item Type and Sequence Displays the macro item type and the item sequence for
macro items belonging to the same item type defined for the same typical block.
Macro Item Name Displays the name of the electrical item that the selected macro is
associated with.
Macro details
Macro item type and sequence Displays the macro item type and the item sequence for
macro items belonging to the same item type defined for the same typical block.
Macro item name Displays the name of the electrical item that the selected macro is
associated with. Select another electrical item if you want to change this association.
Show macros of selected block Allows you to select to display the macro data for the block
you selected in the Block tab folder.
Show all macros Allows you to select to display the macro data for all the blocks you
belonging to the selected typical schematic.
787
788
Display Unit Of Measurement Labels - Displays the units of measurement in the value field.
Set printer paper size to sheet size - Automatically sets the printer paper size to match the
sheet size (if the printer supports that size).
Display XY coordinate readout - Displays the XY coordinate of the cursor position in the right
side of the application window status bar.
Undo Steps - Sets the number of operations that can be undone.
Middle Button Operation - Sets up the middle mouse button so that it can be used for either
scrolling or panning. The default action of the middle mouse button is Windows Scrolling.
789
790
791
792
SmartSketch
Line Style
Number
Line Style
Number
Solid
Normal
Dotted
Dashed
10
Medium Dotted
Dotted
11
Long Dotted
Dash Dot
12
Dot Dash
Dash 2Dot
13
Short Dash
Chain
18
Double Chain
20
2Dash Dot
21
793
MicroStation
Line Style
Number
Line Style
Number
Normal
Solid
Dashed
10
Dotted
Dotted
11
Medium Dotted
Dash Dot
12
Long Dotted
Dash 2Dot
13
Dot Dash
Chain
18
Short Dash
Double Chain
20
2Dash Dot
21
794
SmartSketch
Line Style
Number
Line Style
Number
Solid
Normal
Dotted
Dashed
10
Medium Dotted
Dotted
11
Long Dotted
Dash Dot
12
Dot Dash
Dash 2Dot
13
Short Dash
Chain
18
Double Chain
20
2Dash Dot
21
795
MicroStation
Line Style
Number
Line Style
Number
Normal
Solid
Dashed
10
Dotted
Dotted
11
Medium Dotted
Dash Dot
12
Long Dotted
Dash 2Dot
13
Dot Dash
Chain
18
Short Dash
Double Chain
20
2Dash Dot
21
You can set the software to look for files on another machine. To connect to another
machine, click the Modify button to define other directories or network paths.
796
797
798
Document
Allows you to define a document name and description of a single line diagram that you are going
to generate.
Document number Allows you to type an SLD name.
Description Allows you to type a short SLD description.
SLD type
Allows you to select a type of SLD that you want to generate. These options are not available
when generating PDB-based single line diagrams.
Conventional Generates a full and unfiltered single line diagram that includes all the
associated cables, converting equipment, and loads.
Overall Generates an SLD that displays multiple levels of buses but does not include
individual loads. The following table specifies the items that are included in overall SLDs:
Item
Displayed in SLD
Power sources
Shown
Buses
Circuit internals
Feeder circuits
Converting
equipment
Shown
Loads
Not shown apart from motors and heaters that have a minimum
rated power setting defined on the Miscellaneous tab.
Cables and
busways
Based on bus rated voltage Generates an SLD based on the bus rated voltage that you
select from the list below.
Electrical analysis SLD Generates a single line diagram that you can publish to an
electrical analysis application such as ETAP. Also, after selecting this option you have to
define the options for circuits and circuit internals on the Circuits and Internals tab.
799
800
Page settings
Enables you to define the size of the active generation area.
Default SLD template Generates a single line diagram based on the default template file you
define in Options Manager.
A0 wide template file Generates a single line diagram based on the A0 wide template file
provided to you by the system. This template file is called A0_Template.spe and the software
sets its default location in Options Manager under Default Report Template Path. You can
change this location if needed but do not delete this file.
Selected template Generates a single line diagram based on the template file you select from
the list below this option button.
801
SLD margins
Enables you to define the distance between the page edges and the SLD so that the drawing does
not overlap the title block.
Top Allows you to type a value in inches for the top drawing margin.
Bottom Allows you to type a value in inches for the bottom drawing margin.
Right Allows you to type a value in inches for the right drawing margin.
Left Allows you to type a value in inches for the left drawing margin.
Units Allows you to select a unit of measure for the SLD margins.
Circuit internals
Enables you to define the presentation of circuit components.
Show only enabled circuit internals Includes only those circuit components in the single line
diagram for which the Is SLD parameter in the Properties window is set to TRUE.
Show all circuit internals Includes in the single line diagram all the circuit components
regardless of their Is SLD parameter setting in the Properties window.
Do not show any circuit internals Excludes the circuit components in the generated single
line diagram.
Distance between circuit internals Enables you to define the vertical distance between the
circuit components in the generated SLD.
Options for electrical analysis SLDs Enables you to define the presentation of circuits and
circuit components in an electrical analysis SLD. Note that these options are only available after
selecting Electrical analysis SLD on the General tab. This is used to publish SLD to a third
party analyst application such as ETAP.
Show only circuits Includes circuits but does not show any circuit components in generated
electrical analysis single line diagrams.
Show only circuit internals Includes only circuit components but without the circuits.
Do not show circuits or circuit internals Excludes circuits and the circuit components in the
generated single line diagram.
802
Display options
The options in this group box allow you to do the following:
Control the placement and position of the incomer and feeder circuits on the bus in an SLD
drawing.
Instruct the software to break the bus symbols on the drawing into several sections. You can
use these options if an SLD for a PDB includes a large number of circuits so that the labels on
the SLD drawing are more legible. The number of sections for each bus is determined by the
maximum number of incomer and feeder circuits per bus section that you define.
803
Note that bus risers and couplers are always displayed on the same page adjacent to
each other.
To ensure that all the circuits are placed correctly, all the circuits must have sequence in
group values. The software places the circuits that do not have sequence in group values
first and only then the rest of the circuits.
Force bus breaks Breaks the bus symbols on the drawing into sections and places them in
rows underneath each other. The software displays the electrical items on the buses in several
rows according to the bus breaks. You can move the individual bus sections and place them on
the drawing as you require. Also, you can move the incomer and feeder circuits from one bus
section to another on the same bus.
Clear this check box to instruct the software not to break the bus symbols into sections and display
of all the circuits on the same row.
The bus break options only apply to SLDs that are based on power distribution
boards generated from the Electrical Index.
Maximum number of circuits per bus section to display This option becomes available
when you select Force bus breaks. Enter the maximum number of circuits to allow on each row
of the drawing. The software forces bus breaks wherever the number of circuits on the bus
exceeds the specified value.
When forcing bus breaks, the software places the maximum number of feeder circuits on
the first bus section according to the value that you enter. Then, the software places the
rest of the feeders on the next section. For example, if you enter 3 as the maximum
number of feeders per bus section and there are 5 feeders on that bus, the software will
place 3 feeders on the first section and the other 2 feeders on the second bus section.
All the incomer circuits for each bus are drawn on the first bus section only.
You can move the incomer and feeder circuits from one bus section to another bus
section on the same bus as you require. Click an incomer or a feeder circuit symbol to
select it and then drag its connection point on the bus to another bus section of the same
bus.
Where two buses are connected by a coupler-riser, the software does not force a bus
break across the connection. Instead, the software draws the first bus section and then
counts the feeders from the riser on the second bus section before forcing the break. For
details, see Bus Break Example (on page 805). Note that you can move coupler and riser
circuits to another section of the same bus just like any other circuit.
Use multiple sheets Displays each row of items on a separate drawing sheet. When
selected, the software uses off-page connector symbols with appropriate labels to show the
continuation between adjacent sheets. Clear to display all the items on a single drawing sheet.
804
Suppose you have a PDB SLD with three buses that have the following arrangement:
Bus A has two incomers (CKT-I1 and CKT-I2) and 8 feeder circuits (CKT-1A to CKT-8A).
Bus B has an incomer (CKT-I3), 4 feeder circuits (CKT-1B to CKT-4B), and a coupler circuit,
CKT-5B (C).
Bus C has two incomers (CKT-I4 and CKT-I5), 4 feeder circuits (CKT-2C to CKT-5C), and a
bus riser circuit, CKT-1C (R).
The bus riser-coupler pair connects buses B and C.
The diagram appears as follows when there are no bus breaks, with illegible labels:
The drawings below show how different parts of the SLD appear when you select to force bus
breaks and specify a maximum of three feeder circuits to display per bus section.
805
806
807
808
The software does not display control station properties in the Properties window when you
select a control station in an SLD.
The software does not allow you to compare control station changes with an archived SLD.
Legend
Enables you to include a legend that explains the SLD symbols used in the drawing. Note that
once an SLD contains a legend, you can drag the legend and move it like any other element in an
SLD. An SLD legend contains all the symbols that the software uses to represent all the electrical
items in a single line diagram. Also, the software shows custom symbols if you have defined the
Electrical Equipment Type property and selected a symbol from the Symbol Name list in the
Properties window for a particular electrical item.
Draw legend Adds a legend in an SLD.
Horizontally Positions the legend horizontally.
Vertically Positions the legend vertically.
809
810
811
Symbols
Associate Custom Symbols Dialog Box
This dialog box allows you to associate a customized symbol file with each available document
type (drawing), for each specific item you use in SmartPlant Electrical.
Item Tag Displays the item tag selected for associating a symbol with.
Document Type Allows you to select the document type for the item tag that you want to
associate.
Symbol Allows you to select the custom symbol you want to associate with the document type
and item tag. Click
, to view the custom symbols in the default Symbols folder and its
sub-folders. The default Symbol folder is defined under Options > Locations in the SmartPlant
Electrical Options Manager.
Add Adds a new row for defining a document and symbol association. The Add button is
deactivated when no more rows can be added.
Remove Removes the selected row from the item tag.
Tabular Editor
A compound filter consists of more than one simple filter. Simple filters are added to the
compound filter either by dragging the simple filter to the compound filter folder or by creating new
simple filters under the compound filter in the filter hierarchy. Compound filters apply only to
homogeneous item types. This dialog box specifies the properties of a compound filter, including
the name, description, and whether to match all or any of the simple filter criteria.
Name Specifies the filter name. The name can be any combination of characters and has no
length limit. Filter names within a plant must be unique. This name appears as the filter name on
the Filter Manager interface.
Description Specifies a phrase or sentence about the filter. The description can be any
combination of characters and has no length limit. The description appears as a ToolTip when you
point to the filter name on the Filter Manager interface.
Filter method
Allows you to decide whether items must meet all or only one criterion to pass through the filter.
Match all Specifies that items matching ALL of the filtering criteria pass through the filter.
Match any Specifies that items matching any one or more of the filtering criteria pass through
the filter. Match any is the default matching method.
812
Base filter
Displays details of a saved filter.
Name Displays the name of the filter as defined in Filter Manager.
Default Indicates if the named filter is the default filter for the item type selected on the Table
Properties dialog box. You can designate a filter as the default by checking this box.
Browse Opens the Select Filter dialog box, which allows you to select a base filter.
Definition
Allows you to add, remove, or edit filter criteria and to specify the relationship between multiple
criteria.
Match all Specifies that items matching ALL of the filtering criteria pass through the filter.
Match any Specifies that items matching any one or more of the filtering criteria pass through
the filter. Match any is the default matching method.
Add Places a new entry at the end of the existing definition list and enables the options in the
Edit group so that you can edit the new entry.
Delete Removes the selected criterion from the definition list. This button is available only when
you select a criterion in the definition list.
Edit
Provides options that allow you to define or edit a single line of filter definition criteria.
Property Displays a list of all properties for a certain item type. Examples of properties
include Equipment Type, Instrument Type, and Estimated Length. You define or modify filtering
criteria by selecting a property, an operator, and a value.
Operator Specifies the relationship between the property and its value. Relationships include,
for example, greater than, >; equal to, =; not equal to, <>; and so forth.
Value Lists appropriate values for the property specified in the Property column. If a list of
attributes is not already associated with the Value box, you must type a value, which can be free
text, or choose null. You can type a percent sign, %, as a wildcard character to find multiple
characters, or type an underscore, ( _ ), as a wildcard character for a single character. Do not use
an asterisk, *, in the Value box.
813
814
815
Show
Allows you to specify which types of errors appear in the log files.
All log file data Displays data and rule inconsistency errors.
Rule inconsistencies only Displays rule inconsistency errors only.
All log file data excluding rule inconsistencies Displays data errors only.
Show log file data for last operation only Select to display errors for the last performed
operation relating to the specified log file. Clear to display accumulated errors for successive
operations.
Open Opens a log file of the selected category in Microsoft Excel. After generating the log file
in Excel, you switch back to the Log File Selection dialog box and select another
category. Clicking Open displays the log in the same Excel workbook but in a different
worksheet.
Close Closes this dialog box.
816
Summary
Total number of items Shows the total number of items that you selected in the Electrical
Index or Tabular Editor.
Inconsistency Type Indicate the type of rule inconsistency, if any, that the software
found. The following levels are indicated: No inconsistency, Logged, Warning, and Rejected,
according to the options specified in the Rule Manager.
Number of Items Indicates the number of selected items that the software found with
inconsistencies corresponding to the indicated inconsistency type.
Cancel Cancels the processing while the software is checking items for rule
inconsistencies. When the software has finished checking all the selected items, this command
changes to Close.
Show Log Displays an Excel file showing details of rule inconsistencies that the software found
for the selected items.
Data Window
Displays the rules with details of inconsistencies and the action to be taken.
Rule Name The name of the rule as defined by the user. The same rule name can appear
more than once if several inconsistencies exist for that rule.
Inconsistencies Indicates the way in which the data is inconsistent with the rule for the
specified item. The following example specifies an inconsistency for a rule whereby a 100hp
motor must have a rated voltage of at least 400V:
Motor=100hp(M-A-1000):Rated Voltage(220V)>=(400V)
Where the components of the formula are as follows:
Component
Value
Operand 1
Motor=100hp
Item tag
(M-A-1000)
Property
Rated Voltage
(1000V)
Operator
>=
(400V)
817
818
Component 1
Displays the first rule component and set or changes the rule type.
Filter or item type Displays the first rule component.
Single component Indicates the rule type. When this check box is selected, the software
uses a single component rule for the component specified in the Filter or item Type box under
Component 1. A single component rule enables you to evaluate and validate consistency of the
properties or property values of a specific item tag.
Component 2
Available only when the rule type is a relation rule. Specifies a second rule component, which the
software can display as an operand in logical relations in the Consistency tab.
Filter or item type Displays the second rule component.
The order of the rule components is not important. Relation rules are be bi- directional. If
your rule components are different, and in the Consistency tab you create a logical expression
using both components as operands, the rule applies to any of the components involved in user
operations in SmartPlant Electrical.
819
Consistency criteria
Displays the consistency criteria which consist of one or more logical expressions and an action
associated with specific expressions. A logical expression is a relationship created between two
operands by means of a logical operator.
A logical expression consists of the left and right parts separated by an operator:
Left part Must always contain Operand 1 and its property, where Operand 1 represents a
rule component.
Right part Can contain either a rule component as an Operand 2 and its property or the
Value operand and a value specified for the property of Operand 1.
Operand 1 Displays a rule component specified in the Rule Components tab. If the rule type
is single component, the cell displays the rule component specified on the Rule Components tab
under Component 1.
Property Lists appropriate properties for the rule component that appears in the Operand 1
list.
Operator Displays the operator for the logical relation. For details about operator descriptions,
see Operator Descriptions and Rule Examples (on page 35).
Operand 2 Displays a rule component specified in the Rule Components tab or the Value
operand of a property selected in the Property column. For a rule component, this column
displays the relationship between properties of rule components. For the Value operand, this
column displays the relationship between the rule component property and the property value.
Property/Value Depending on the selection in the Operand 2 column, lists properties or
values. If the Operand 2 column contains a rule component, this column displays a property of a
specific item type or filter. If the Operand 2 column contains the Value operand, this column
displays the value for the property defined in the Property column. Depending on the operator, a
value can be free text, a number of units of measure separated by commas or semi colons, or a
value selected from the list.
Action Displays the action for the software to perform in case of inconsistency. In SmartPlant
Electrical, the software applies an action only when the software detects a rule inconsistency (that
is, whenever a user violates the logical expression with which you associate the action). The
software records rule inconsistency details into a log file which you can generate from SmartPlant
Electrical.
820
Wiring
Batch Cable Connection Dialog Box
Allows you to connect, in batch mode, numerous project cables that belong to the same category,
for example, power, control, instrumentation, and so forth. For example, you can you can
terminate all the project control cables that are associated with 10hp motors.
821
to open a dialog box where you can type longer text for the description.
When typing the description in the dialog box, to begin a new line, press CTRL + ENTER.
Skip between sets Allows you to enter the number of terminals that you want to skip between
the first conductor of the previously connected set and the first conductor of the next set.
822
Configuration properties
Total number of terminals Allows you to enter a number of terminals to be created on the
current terminal strip. Note that this number should always be higher than the
First terminal Allows you to type or select a starting number of the first terminal on the current
terminal strip.
823
to open a dialog box where you can type longer text for the description.
When typing the description in the dialog box, to begin a new line, press CTRL + ENTER.
824
to open a dialog box where you can type longer text for the description.
When typing the description in the dialog box, to begin a new line, press CTRL + ENTER.
Terminal strip Displays the terminal strip that is associated with the current terminal.
Type Allows you to select a type for the current terminal. You can define and customize types
in Data Dictionary Manager.
Terminal color Allows you to select a color for the current terminal. You can define and
customize terminal colors in Data Dictionary Manager.
Sequence Allows you to enter the sequential number of the current terminal on its terminal
strip.
825
SECTION 40
827
Align Ribbon
Align Left Aligns the left side of objects in a select set.
Align Right Aligns the right side of objects in a select set.
Align about Horizontal Aligns the objects in a select set along
their horizontal centers.
Align about Vertical Aligns the objects in a select set along
their vertical centers.
Align Top Aligns the tops of objects in a select set.
Align Bottom Aligns the bottoms of objects in a select set.
828
Change Toolbar
The Change toolbar contains commands that you can use to modify the graphic elements in a
drawing. You can activate the Change toolbar by using the View > Toolbars command.
Icon
Description
Move Moves elements from one location to another.
Align Allows you to align two or more elements in a selection
set.
Nudge Moves a drawing item using keypad arrows.
Offset Draws an offset copy of an element or a set of contiguous
elements.
Rotate Rotates one or more elements.
Mirror Mirrors one or more selected elements about a line that
you define.
Scale Reduces or enlarges selected elements by a scale factor
that you define.
Bring to Front Moves a selected element to the front of the
display order.
Send to Back Moves a selected element to the back of the
display order.
Pull Up Moves a selected element up one position in the display
order.
Push Down Moves a selected element down one position in the
display order.
Connect Makes a point fixed on another element.
Horizontal / Vertical Makes a line or two points horizontal or
vertical.
Parallel Makes two lines parallel.
Perpendicular Makes a line or arc perpendicular to another
element.
Tangent Makes two elements tangent.
Colinear Makes two lines colinear.
Concentric Makes two arcs or circles concentric.
Symmetric Makes two elements symmetric.
Equal Makes two elements or dimensions equal.
Lock Locks an element so that it cannot be moved.
Relationship Handless Toggles the display of relationships
within the active window.
829
Description
Alignment Indicator Turns on the horizontal and vertical
relationship indicator.
Draw Toolbar
The Draw toolbar displays by default docked to the left side of the interface. You can use the
commands on this toolbar to place the basic elements of your symbol.
Select Tool Use to select, modify, and manipulate elements.
Line Draws one line or a series of connected lines.
Tangent Arc Draws an arc tangent or perpendicular to one or two
elements.
Line/Arc Continuous Creates lines and arcs.
Circle by Center Point Draws a circle using a center point and
radius.
Ellipse by Center Point Draws an ellipse using the center point
and two edge points.
Rectangle Draws a rectangle using three points.
Curve Draws a smooth, open or closed curve.
FreeSketch Draws lines, arcs, rectangles, and circles by converting
a sketch into a precision drawing.
Fillet Draws a fillet between two elements.
Chamfer Draws a chamfer, or bevel.
Trim Trims open and closed elements to the closest intersection in
both directions.
Extend to Next Extends one or more open elements until they
intersect with the nearest element.
Connector Connects two elements together.
830
831
Label Toolbar
The Label toolbar allows you to attach various types of labels to symbols
SmartDimension Dimensions all geometry.
Distance Between Dimensions the distance between elements.
Angle Between Dimensions the distance between multiple
elements.
Axis Sets the dimension axis.
Coordinate Dimension Places a coordinate dimension.
Symmetric Diameter Places a symmetric diameter dimension.
Measure Distance Measures the distance between two points.
Measure Area Measures the area of closed areas.
Text Box Creates a box where text can be entered.
Character Map Provides access to the Microsoft Character
Mapping functionality.
Leader Adds leaders to annotation elements or existing leaders.
Balloon Places a balloon next to an element or a free space point.
Fill Fills a closed region.
Main Toolbar
The Main toolbar contains commands for the most common commands in the software. This
toolbar is displayed by default docked to the left side of the interface.
New Item Creates a new item of the selected item type..
Open Drawing Opens an existing drawing.
Save Saves the active document.
Print Prints the open file.
Cut Deletes the selected item and moves it to the Clipboard.
Copy Copies the selected item to the Clipboard.
Paste Pastes the contents of the Clipboard.
Delete Deletes the selected items.
Duplicate Duplicates the selected item.
Select Tool Selects drawing elements.
Zoom Area Allows you to select an area on the drawing that zooms to
832
833
List
Line Start Terminator Sets the terminator for star ting the
connector.
List
Line End Terminator Sets the terminator for ending the connector.
Diagonal Mode (ALT) Allows you to either place or modify a
connector with diagonal segments.
Insert Segment Mode (ALT+S) Inserts line segments into the
connector.
834
List
List
835
SECTION 41
Using Help
Online user assistance makes command information available as you perform tasks. You can
access different kinds of information any time that you are running the software. This information
includes reference topics, narrative descriptions, or instructional material.
The software offers the following important user-assistance features:
Online Help
A structured table of contents, an index, and full-text search capabilities provide easy access to
Help topics. Press F1 any time you need online Help during a session. You can access the table
of contents by clicking Help > Electrical Help, or by clicking the Help command on the toolbar.
Learning Tools
You can click Help > About Electrical to see your software version and license information.
Printable Guides
You can click Help > Printable Guides and choose to display the Help contents in portable
document format (.pdf). Then you can print the file if necessary.
837
Using Help
838
Glossary
A
active power
The quantity of electrical power (in W, kW, or MW) supplied to a consumer that is capable of
producing actual work. See also: rated active load, consumed active load.
actual length
A derived value that SmartPlant Electrical uses for cable sizing, cable drum assignment, and so
forth. If a cable has a value for Estimated length, but no value for Design length, then the
Estimated length is also the Actual length. If there is a value for Design length only, then this is
also used as the value for Actual length.
annotations
Dimensions, notes, symbols, or reports that you place in a drawing to provide information or
comments.
ANSI
American National Standards Institute.
apparent power
The quantity of electrical power (in VA, kVA, or MVA) that represents the vector sum of the active
load and reactive load for a motor. This quantity is the actual power that the electricity supply
company needs to generate.
As-Built
The operational plant that is used as the source of data for your projects.
asynchronous speed
The maximum attainable rate of rotation of a motor shaft, in rpm. This quantity is always less
than the synchronous speed because of energy losses due to the magnetic field, pole
architecture, and so forth.
839
Glossary
attribute
1. A property or characteristic of a component.
2. A characteristic that all members of a class possess. Each property has an associated value
that defines its current state. Most databases represent an attribute by a column in a table.
average power
The average electrical power consumption for a consumer, used to calculate overall electrical load
requirements. The average load is calculated by multiplying the rated active load by the
operating factor.
B
block
A block is the basic drawing unit of a schematic. Each block graphically represents the
functionality of an item or a related group of items. Each block must belong to a block type, which
you can use to classify the blocks according to the items they represent; for example, a motor and
its cables, or a circuit block with its bus, cell, and PDB. The block also specifies the drawing file
that contains the graphical information for the items.
block
A block is the basic drawing unit of a schematic. Each block graphically represents the
functionality of an item or a related group of items. Each block must belong to a block type, which
you can use to classify the blocks according to the items they represent; for example, a motor and
its cables, or a circuit block with its bus, cell, and PDB. The block also specifies the drawing file
that contains the graphical information for the items.
brake power
The minimum mechanical power required to make the motor shaft rotate and drive the pump or
process equipment attached to the motor.
bucket
See cell.
buffer
A temporary data store used for setting aside items before you decide whether to scope those
items.
840
Glossary
bus riser, bus tier
See riser circuit.
busbars
Busbars are used in place of standard cables to interconnect electrical equipment requiring high
current. They consist of strips of copper, usually arranged in groups of three or four. Each set of
busbars operates at a specified rated voltage.
C
cell
A removable compartment in a power distribution board that contains circuitry.
claim
Selection of an item in a project so that it can be edited in that project.
claim mode
Indicates whether a claimed item is available for all available projects (shared claim) or only for the
selected project (exclusive claim).
coincidence factor
The fraction of the maximum possible utilization of the motor for a specified operating mode. The
software uses this factor when calculating the total load consumption of a power distribution board
or electrical system.
compartment
A section of a power distribution board that contains the required circuitry.
consumer
See load.
841
Glossary
control station
A local or remote panel containing a low-voltage circuit, used to control the operation of a motor
via a control circuit.
converting equipment
Equipment used to convert one level or type of electric property to another. Converting
equipment includes transformers, battery chargers, UPS units, and variable-frequency drives
(VFDs).
coupler circuit
A circuit that connects two buses in a power distribution board for the purpose of creating a bus tie.
This circuit belongs to the bus that serves as the power source of the coupled bus in the PDB.
cubicle
See cell.
D
data dictionary
The underlying data model of a plant, consisting of database entries and select lists. SmartPlant
Data Dictionary Manager maintains this information.
data model
Application items that populate a project. Typical items in a data model are components, lines,
and labels.
demand factor
A quantity expressing the ratio of brake power to motor rated power. The demand factor can
have values between 0 and 1.
demand point
The point where the motor operates at its brake power.
842
Glossary
disconnect electrical equipment
Equipment used to disconnect a load from the power supply. Disconnect electrical equipment
includes switches, starters, overload relays, fuses, circuit breakers, and protection relays.
distribution board
A box divided into panels, used to distribute the power supply to the various loads, and to
transform the voltage as required. See also: power distribution board.
distribution equipment
Equipment used to distribute the power supply among several loads. Distribution equipment
includes power distribution boards (PDBs), motor control centers (MCCs), disconnect electrical
equipment, cables, and panels.
drawing file
A file in which you place items; also called a design file.
E
efficiency
A quantity expressing the ratio of useful power output to power input. Efficiency can have values
between 0 and 1.
enclosure
The physical housing of a piece of electrical equipment used to protect the equipment from its
environment.
enclosure protection
The level of protection afforded to a motor from its environment. For example, the operational
environment of the motor may require that the enclosure is sealed or explosion-proof.
843
Glossary
EPC
Engineering Procurement Contractor: a company that has responsibility to design and erect a
plant.
F
feeder
A circuit that distributes power from a distribution board downstream to other types of equipment.
frame size
A US standard that defines the physical and mechanical properties and dimensions of a motor.
I
IEC
International Electrotechnical Commission, a European electrical standard.
incomer
A circuit that supplies power to a power distribution board.
L
load (consumer)
An electrical device, such as a motor or heater, that draws power from the electrical distribution
network.
load center
See power distribution board.
844
Glossary
load factor
See demand factor.
M
macro
A macro is a string attached to a graphic block that represents the item type and one of its
properties. You can assign one or more macros to a block. When you generate a schematic
drawing, the software reads and resolves the macros so that it can retrieve the value of the
property from the database and display it in the drawing.
main item
A term used to describe almost any item added in As-Built that can be a focal item with related
items. Main items can include loads, converting equipment, power sources, free cables, PDBs,
and documents. You can only scope main items if they are included in a plant group that has
been scoped.
merge
The action of moving items whose data was modified in a project back to the As-Built schema.
845
Glossary
miscellaneous drawings
Drawings that you create based on a template, to which you can add symbols. You can revise
miscellaneous drawings, as you can any other SmartPlant Electrical document, and associate it
with any item in your plant.
motor speed
The rate of rotation of the motor shaft, in rpm. Motor speeds are characterized by two standard
quantities: the synchronous speed and the asynchronous speed.
N
naming convention
The naming convention is a means of ensuring a consistent structure and maintaining uniqueness
of tags for items of the same type. Once you define a naming convention for an item type such as
motors, the software tags any new items of that type using the mask and structure of the naming
convention. The naming convention is a combination of properties, text strings, and separators
that makes up the tag structure in the Electrical Index. You define naming conventions in the
Options Manager.
NEC
National Electric Code, a US electrical standard.
O
operating factor
A quantity expressing the ratio of the load power requirement at the operating point to the rated
power. The operating factor can have values between 0 and 1.
846
Glossary
operating mode
A description of how the motor is used in practice in the plant. The operating mode can be:
continuous, intermittent, normal, standby, or spare, and a quantitative measure of the motor
behavior in each mode is provided by the coincidence factor.
operating point
The point where the motor operates under normal working conditions.
owner operator
A company that owns and operates a plant.
P
panel circuit
A circuit that can be created in a local panel or a junction box.
particular power
Under the IEC Standard, the mechanical power that a motor shaft is required to supply when
operating under a specified set of conditions, for example, once a year.
plant
A group of facilities and equipment that performs one or more material processing functions within
a given geographical area. One company can have several plants located at different
geographical locations.
847
Glossary
profile
A profile is an assembly of various typical items that you can use as a template for creating project
items. For example, you can create a motor profile that consists of the following reference items:
a motor, one or more cables, a control station, a circuit with protection devices, and schematic.
project
A separate electrical schema within a plant used to claim items for updating when performing
routine maintenance or modernization (revamp) for that plant. To facilitate plant modernization,
you can create a number of projects within a single plant. Within a particular plant, the projects
and As-Built have a common reference schema and data dictionary.
project status
Describes the status the project as a whole. Possible statuses are: Active, Completed, Merged,
or Cancelled.
property
A unique characteristic of an object, item, symbol, or document.
The properties of an item can include display properties and properties stored with the item. For
example, the properties of a valve symbol can include display properties such as color, line style,
and width. Other properties stored with the valve symbol can include the manufacturer, cost, or
material. Properties stored with the valve symbol are displayed in the Properties window when
the valve symbol is selected.
R
rated active load
The maximum quantity of electrical power used by a consumer when operating at the rated power.
rated power
The maximum output power that a load can produce. See also: motor rated power.
rated voltage
The voltage at which a piece of equipment is designed to operate. This quantity is required to
ensure electrical compatibility between the electrical supply and the equipment.
848
Glossary
reactive power
The component of the supplied electrical power (in VAR, kVAR, or MVAR) that the load uses to
provide reactive energy.
reference data
A collection of information containing facts relative to industry design codes, catalog data of
vendors, job specifications, commodity libraries, graphics symbology, label descriptions, report
formats, and other information of a similar theme.
related item
An item that has an electrical relationship to a main item and which the software scopes
automatically when the main item is scoped. Related items may include control stations,
associated cables, circuits, and signals. Some scoped items may belong to unscoped plant
groups.
relation rule
A rule in which consistency criteria apply to two specific components. Relation rules ensure that
correct relationships are created when you create a new relationship or modify properties or
values of related items in SmartPlant Electrical.
report template
An online outline for a new report that you need to define. You can select a user-level or a
project-level template to create a new report template.
resistive load
A load that has resistive characteristics.
riser circuit
A circuit that connects two buses in a power distribution board for the purpose of creating a bus tie.
This circuit belongs to the bus that serves as the receiver of backup power from the feeder bus in
the PDB.
849
Glossary
rotor
The rotating part of a motor or generator.
run-up rime
The time it takes a motor to reach its operating speed after switching on the power.
S
schematic
A graphical representation of the wiring of a load, its feeder circuit and its controls, which includes
specific data for that particular load.
schematic file
Schematic drawing or diagram of a particular item in the plant.
scope
In Engineering Manager, the scope defines the extent of the items that you are able to view and
subsequently claim, based on plant group levels of the project. In SmartPlant Electrical, any item
that you scope in As-Built becomes available for viewing in the project. When you select and
scope main items, the software includes certain related items in the scope.
search criteria
Set of values used to scan a database or object library.
segregation level
A term used to group cables that share a common electrical signal and can therefore be run along
the same routing path. You use segregation levels to distinguish between different groups of
cables that if routed together could produce electrical or magnetic interference. Examples of
such groups include high or low voltage cables, cables of different types or sources, or cables
associated with different applications or systems.
server
In network operations, the node that maintains common data or performs a common task that
clients need. All network operations between two or more nodes establish a client/server
relationship.
850
Glossary
shaft
The part of a motor or generator that drives the attached equipment.
signal
An item type that is used for mediating between SmartPlant Electrical and SmartPlant
Instrumentation. You can associate a signal with a load, a control station, or a circuit for the
purpose of publishing data to SmartPlant Instrumentation. You can perform wiring connections
in SmartPlant Instrumentation and retrieve the host information back to SmartPlant Electrical,
where it appears as read-only properties of the signal. SmartPlant Electrical can then use the
values of those properties to display I/O assignment information in a schematic.
static load
Equipment that does not rotate; for example, heaters, lighting equipment, other machines are
static loads.
stator
The stationary part of a piece of rotating electrical equipment, such as a motor or generator.
strip
A termination item used for making wiring connections. A strip is always at the lowest level in the
hierarchy of distribution equipment.
switch board
See power distribution board.
switchgear
See power distribution board.
851
Glossary
synchronous speed
The maximum theoretical rate of rotation of a machine shaft, in rpm, assuming no energy losses
due to the magnetic field, pole architecture, and so forth. See also: asynchronous speed.
T
Te stall time
The time it takes a motor to come to rest after switching off the power.
U
unit
Group of parts of the schematic and individual worlds of a plant that together perform a given
process function. The identifying number of the unit is unique within the project and within the
plant. Most companies, but not all, use the concept of unit.
852
Index
A
actions 819, 820
description 820
Log 820
Options Manager settings 820
Reject 820
rule priorities 819
Warn 820
aligning 357, 359, 360, 828
Align command 360
align ribbon 828
drawing objects 359
overview 357
alternative feeders 119, 120, 121
associating 120
changing 120
dissociating 121
annotations 273, 278, 349, 350, 351
deleting 351
editing 350
in schematics 273, 278
inserting 349
inserting graphics 350
overview 349
applying 126, 668, 671
applying options
batch mode 126
lookup tables to items 126, 671
overview 125
profiles 130, 668
typical circuits 669
typical control stations 128
typical I/O sets 672
typical schematics 671
As-Built
adding items 456
claiming items overview 457
comparing with project documents 462
filtering the display 466
generating a report 467
merging into As-Built 464
merging into As-Built overview 462
modifying a project status 452
project management overview 449
Project Management Table (As-Built)
748
Project Management Window (Project)
751
853
Index
power cables with equipment 198
AutoCAD 588
autofilter 378
automatic drum - cable assignment 621,
622
B
batch application of options 126
batch item creation 82
batch load association 205
batch operations 820
Options Manager settings 820
Warn action 820
batch sizing cables 147, 624
compare documents 733
battery banks 78, 79, 101, 128, 196, 680,
681, 682
applying typical control stations 128
associating with control stations 196
controls and signals 682
creating 101
deleting 79
duplicating 78
electrical data 681
general data 680
instrument data 682
battery chargers 78, 79, 102
adding 102
deleting 79
duplicating 78
blocks 51, 52, 265
sequencing items 265
brief properties 72, 75, 76
bulk properties 72, 74, 75
bus riser circuits 122, 196
associating with coupler circuits 196
creating 122
bus ties 196
buses
associating a single load 208
associating electrical equipment with
feeders 194
associating loads in batch mode 205
calculating load summaries 253
calculating load summaries overview
214
calculating loads for all buses 253
changing bus symbols in SLDs 285
creating 106
creating stand-alone buses 107
deleting 107
displaying associated loads 211
displaying bus load data 211
854
C
cabinets 743, 744, 745, 746
electrical data 744
feeder data 745, 746
general data 743
cable block diagrams
creating diagram 324
finding items in the EI or EE 355
hiding cables 329
opening existing diagram 319
overview 317
removing items 327
show related items 356
cable drums
assigning cables to 175, 176
automating splicing 177
batch assigning cables 177
calculations 181
creating 174
editing 175, 639
properties 639
rules 181
selecting reference cables for 175, 650
unassigning cables from 182
cable route 664
properties 664
cable routing 165, 166, 167, 169, 172, 308,
309, 628, 657, 659
assign components to segments 166
assigning cables 628
batch mode 657
batch routing cables 166
clearing 167
create cableway and segments 165
defining 166
edit cableway 169
overview 165
segment fill 169, 172
segment validations 308, 309, 659
setting calculation criteria 172
setting validation method 172
validation 169, 172
cable sets 340, 341, 641
connecting 340
disconnecting in wiring drawings 341
properties 641
cables
adding 140
Index
adding parallel power cables to equipment
198
adding reference cables 139
applying reference data 620
associating bus riser circuits with coupler
circuits 196
associating glands 143
associating non-power cables with
equipment 199
associating power cables with equipment
198
associating with control stations 43, 136,
197
automatic assignment to drums 621, 622
batch connection 339
batch sizing 147, 624
cable set properties 641
comparing reference data 642, 643
connection properties 773
connections 632
connections common tasks 334
continuous connection method 337
custom connection method 336
deleting 142
design data properties 628, 772
disconnecting in wiring drawings 341
display / hide multiple cables 183
dissociating cable sides and glands 144
earth loop impedance 573, 637
editing 141
editing reference cable properties 140
general properties 625, 769
overview 139
parallel cables in SLDs 285
procurement 638
procurement properties 773
project 624
reference 769
replacing 155, 647
replacing cable side associations 157
selecting for connection to a control
station 647
sizing 146
sizing algorithms 151
sizing data properties 633
cableway 165, 169
creating 165
editing 169
calculated electric consumption 205, 208,
211
calculations
batch load assignment 249
bus load connectivity 219
855
Index
creating 44, 45, 124
deleting 107
circuit mode 121
associating with lookup tables 122
circuits 44, 45, 107, 122, 123, 124, 138,
194, 195, 755, 756, 757
assigning typical circuit data 123
associated items 757
associating with loads 194
associating with lookup tables 122
automatic creation of feeders 195
circuit breakers 44, 45, 123, 124
creating 122
creating panel circuits 138
creating reference circuits 44
deleting 107
electrical data 756
general data 756
moving 124
claiming 458, 459
adding items 458
claim modes 459
claiming items 458
reclaiming items 459
releasing claim 459
Clear Mark as Completed 460
closing 588, 589
drawings 588
SmartPlant Electrical 589
Tabular Editor 588
common tasks
external documents 369
managing cable drums 175, 176
managing PDBs 105
managing power distribution boards 122
compartments 733
compensated electrical data 214
conductors 340, 341
connecting 340
disconnecting in wiring drawings 341
conformity to standard 633, 693
connecting 612, 647
cables to control stations 647
to databases 612
to plant structures 612
connection points 313
placing on symbols 313
connections 103, 335, 336, 337, 339, 340,
341, 342
batch cable connection 339
connecting cable sets 340
connecting single conductors 340
856
Index
associate symbol 600
deleting a symbol 348
custom validations and calculations 574,
577
customizing 75, 76, 567, 597
data 567
data display 75, 76
toolbars 597
D
daisy-chain connection pattern 202
data customization 567
Data Dictionary templates 407
data display 61, 183
Electrical Engineer 183
Reference Electrical Engineer 61
data model 567
database connection 612
DDT files 407
default DDT file for KKS mode 407
default cables 139, 140, 769
default control stations 774
default data 27
copying 27
default items
adding 40
copying 77
default panels 42, 43
defining 135
defining reference items 40, 42, 51, 139
blocks 51
brief properties 72, 76
bulk properties 72, 74, 75
cables 139
panels 42
project panels 135
report items 398
table layouts 375
tables 605
deleting 79, 142
cables 142
items 79, 589, 590
descending order 619
designing PDB layouts 116, 733
zooming 733
disconnect electrical equipment 690
disconnect switches 44, 45, 123, 124
display rules in Electrical Engineer 183
displaying 72, 73, 75, 183, 597
brief properties 75, 76
data in Electrical Engineer 183
null data 75, 76
properties 72, 73, 75, 597
tables 605
displays 596
filters 596
dissociating 193, 370, 371
batch dissociation of external documents
371
electrical equipment 193
external documents 370
distribution equipment 44, 45, 123, 124
document properties 735, 737
revisions 735, 737
documents
associating external documents 370
associating registered reports 394
compare 733
compare in batch mode 733
comparing As-Built and project
documents 462
comparing documents 367, 368
defining external document references
369
dissociating external documents 370
dissociating multiple items 371
external documents common tasks 369
global revisions 366
opening external documents 371
opening PDB layout for selected PDB
117
opening schematics 279
opening SLDs 293
opening SLDs from Documents folder
294
opening SLDs from Electrical Engineer
294
overview 365
revisions in single documents 365
drag-and-drop rules 63, 187, 192
from the Electrical Index to the Electrical
Engineer 187
from the Reference Electrical Engineer to
the Electrical Engineer 63
within the Electrical Engineer 192
drawing 355
drawing templates 255
drawings 355, 356, 372, 587, 588, 589
creating miscellaneous drawings 372
manipulating 355
miscellaneous 372
properties 589
saving 588, 589
view associated 355
viewing 356
zooming 356
857
Index
drums 621, 622
automatic cable assignment 621, 622
dual source power supplies 119, 120, 121
associating alternative feeder 120
dissociating 121
duplicating 78, 85
items 78
motors 85
E
earth loop impedance 573, 637
editing 43, 46, 52, 53, 56, 73, 78, 83, 136,
140, 141, 175, 395
cable drums 175
control stations 136
electrical motor properties 83
item properties 78
lookup tables 56
profiles 46
project cables 141
properties 73, 374
reference cables 140
reference control stations 43
relationship properties 72
report templates 395, 398
select set properties 72
table items 373
typical control stations 43
typical schematic blocks 52
typical schematics 53
electrical analysis SLDs 447, 799
electrical associations
automatic creation of feeders 195
changing 191
creating 186
daisy-chain connection 202
dissociating 193
finding parent items 185
electrical cables 624, 769
electrical consumption 205, 208, 211
electrical distribution equipment 44, 45,
123, 124
Electrical Engineer 29, 61, 63, 70, 183,
185, 186, 187, 192, 195, 202, 288, 293,
294, 304, 355
automatic creation of feeders 195
daisy-chain connection 202
display rules 183
drag-and-drop rules 192
dragging items from the Electrical Index
186, 187
dragging items from the Reference
Electrical Engineer 63
858
Index
F
feeder circuit location 124
feeders 119, 120, 121, 122, 194, 195, 389,
687, 689, 698, 700, 709, 710, 719, 720,
727, 728, 745, 746
alternative 119
associating alternative feeder 120
associating cabinets with feeders 745,
746
associating converting equipment with
feeders 687, 689
associating instruments with feeders
709, 710
associating loads with feeders 194
associating motors with feeders 698,
700
associating other electrical equipment
with feeders 719, 720
associating static loads with feeders
727, 728
automatic creation 195
changing alternative feeder 120
creating 122
dissociating alternative feeder 121
Enhanced All Feeder Load Summary
report 389
filtering 596
Design window 596
displays 596
filters 596
autofilter 378
properties 666
tables 374, 375
folders 70
customizing sort sequence within folders
70
formats 588
fuses 44, 45, 123, 124
G
gapping 309, 310, 603
generating 382
reports for selected items 382
generators 78, 79, 99, 128, 196, 701, 703,
704
applying typical control stations 128
associating with control stations 196
controls and signals 704
creating 99
deleting 79
duplicating 78
electrical data 703
H
handles 591
harmonic filters 78, 79, 85
adding 85
deleting 79
duplicating 78
heat traces 78, 79, 85
adding 85
deleting 79
duplicating 78
heaters 78, 79, 85
adding 85
deleting 79
duplicating 78
Help 606
hierarchy of plant groups 612
hyperlinks 610
I
I/O signals
associate in batch mode 345
create 344
dissociating 345
overview 344
incomers 122
creating 122
instrumentation cable associations with
equipment 199
instruments 197, 705, 706, 707, 708, 709,
710
associating cables with equipment 197
controls and signals 707
electrical data 706
feeder data 709, 710
general data 705
instrument data 708
interface to SmartPlant Instrumentation
344, 423, 424, 425, 426, 443, 445
creating signals 344
mapping plant groups 425
overview 423
prerequisites 424
publish 443, 445
859
Index
retrieve 426
interfaces 447
ETAP 447
internal documents
adding revisions 365
comparing documents 367, 368
global revisions 366
overview 365
internal equipment 44, 45
internals 123, 124
copying 123
creating 124
item tag 710
J
jumpers 341, 342
connecting 341
customizing symbols 342
junction boxes 43, 137
creating 137
K
KKS 422
KKS mode 405, 407, 409, 413, 416, 417,
420, 421
Classification dialog box 422
configuring for hard-coded tag
propagation 409
configuring for rules 413
configuring SmartPlant Electrical 407
default DDT file 407
overview 405
propagation 416, 417
renaming items 421
scope 420
using default DDT file overview 407
using supplied DDT file 409
L
layers 588
layouts 374, 375, 596
legend 304, 305
in SLDs 304
using custom symbols 305
levels 588
lighting fixtures 87
loads
applying typical control stations 128
assigning to typical circuits 127
assigning to typical I/O sets 132
assigning to typical schematics 129
860
associating 674
associating a single load with a PDB 208
associating with a PDB in batch mode
205
associating with control stations 136,
196
associating with feeders 194
automatic creation of feeders 195
calculating load summaries 253
calculating load summaries for all buses
253
calculating load summaries overview
214
controls and signals 718, 726
creating in batch mode 82
displaying loads associated with a bus
211
electrical data 717, 725
Enhanced All Feeder Load Summary
report 389
enhanced load summary report 254
feeder data 719, 720, 727, 728
general data 714, 722
instrument data 698, 718, 726
load data 716, 723
populating data 125
properties 722
validating 211
local panels 43, 137
log files 29, 33, 34, 35, 588
displaying rule inconsistencies 35
generating 33, 34
preferences 29
viewing 588
logical expressions 35, 820
associated actions 820
description 820
examples 35
operands 820
operators 35
properties 820
values 820
lookup tables 56, 59, 126, 671
adding more regional standards 59
applying to items 126, 671
circuit components 59
defining 56
editing 56
M
macros 116, 256, 262, 265, 274, 397, 398
cell macros 116
definition guidelines 262
Index
for report headers 397
multi-item schematics 274
report macros 398
sequencing items in schematic block
macros 265
title blocks 256
mapping 425
mapping attributes 398
plant groups 425
Mark as Completed 460
Match all 375
Match any 375
measuring transformers 110, 114
copying 114
creating 110
merging 462, 464
into As-Built 464
overview 462
running a test merge 464
metering equipment
copying 114
creating measuring transformers 110
creating meters 111
creating protection relays 112
creating relay functions 112
meters 111, 114
copying 114
creating 111
MicroStation 588
mirroring items 591
miscellaneous drawings 372
associating with electrical items 372
creating 372
inserting symbols 372
overview 372
modifying 73, 619
properties 73
relationship properties 72
select lists 619
select set properties 72
motors 41, 79, 82, 83, 85, 125, 569, 692,
693, 696, 697, 698, 700
adding 82
calculating power requirements 83
controls and signals 697
deleting 79
duplicating 85
editing properties 83
electrical data 696
electrical power calculations 569
feeder data 698, 700
general data 692
load data 693
N
naming conventions 27, 65, 405, 710
copying 27
KKS 405
using 65
new 255, 587, 588
drawing templates 587, 588
drawings 255
tables 374
null data 75, 76
O
opening 117, 255, 256, 279, 293, 294, 612
databases 612
drawing templates 256
new drawings 255
PDB layouts for selected PDBs 117
plant structures 612
schematic drawings 279
single line diagrams for PDBs 294
SLDs 293
SLDs from Documents folder 294
SLDs from Electrical Engineer 294
options 126, 668
other electrical equipment 714, 716, 717,
718, 719, 720
controls and signals 718
electrical data 717
feeder data 719, 720
general data 714
instrument data 718
load data 716
overall SLDs 799
overload relays 44, 45, 123, 124
P
panel circuits 138
creating 138
861
Index
panels 42, 43, 79, 135, 137
adding project panels 135
adding reference panels 42
creating local panels 137
deleting 79
junction boxes 43
local panels 43
panning 356
parallel cables 183
parallel cables in SLDs 285
display / hide 183
parent items in the Electrical Engineer 185
pasting 590
bulk properties 74, 75
items 590
PDB layout design sheets 733
zooming 733
PDBs
a single load with a PDB 208
associating loads 674
associating loads in batch mode 205
associating with loads 194
batch generation of SLDs 291
calculating load summaries 253
calculating load summaries overview
214
calculating loads for all buses 253
common tasks 105, 122
creating 106
customizing border 305
deleting 107
design overview 114
designing layouts 116
designing physical structure 115
displaying in Electrical Engineer 29
Enhanced All Feeder Load Summary
389
enhanced load summary report 254
generating single line diagrams 289
opening PDB layout for selected PDB
117
opening single line diagrams 294
phase association 205, 208
associating single load with a PDB 208
batch load assignment 205
plant groups 26, 425, 612
changing names 26
hierarchy 612
mapping 425
moving items to 612
plant reference data 27
plant structures 612
populating item data 125
862
Index
project cables 140, 141, 142, 143, 144,
146, 147, 155, 157, 620, 624, 642, 643,
647
adding 140
applying reference data 620
associating glands 143
batch sizing 147, 624
comparing reference data 642, 643
deleting 142
dissociating cable sides and glands 144
editing 141
replacing 155, 647
replacing cable side associations 157
sizing 146
project control stations 136, 747
project items 78, 79
deleting 79
duplicating 78
project management
claiming items overview 457
merging into As-Built overview 462
overview 449
project panels 135
projects 450, 451, 452, 453, 458, 459, 460,
461, 462, 464, 466, 467, 754, 755
projects. scoping 450
projects. selecting in As-Built 453
adding items 458
claim modes 459
claiming items 458
comparing documents with As-Built 462
filtering the display 466
generating a report 467
marking items as completed 460
merging items into As-Built 464
modifying a status 452
Project Status dialog box 754, 755
releasing claim 459
releasing items from merge 461
rules for changing statuses 451
running a test merge 464
setting display options 466
understanding statuses 450
propagation 416, 417
in KKS mode 416, 417
properties 72, 73, 74, 75, 76, 589, 594,
597, 610
Properties window 75, 76
brief 75, 76
bulk 74, 75
copying 74
display 74, 75, 76
displaying 72, 73
drawings 589
editing 73, 607
null data 76
table 74, 76
table views 594
tables 374, 605
protection relays 112, 114, 123, 124
copying 114
creating 112
functions 112
publish 391
publish data 443, 445
Q
quitting SmartPlant Electrical 589
R
rated power 205, 208, 211
reclaiming items 459
redlining 349, 351, 352, 353
deleting 353
editing 352
inserting graphics 352
inserting text 351
overview 349
reference cable properties 769
reference cables 139, 142, 650, 769, 772,
773
connection properties 773
deleting 142
design data properties 772
general properties 769
procurement properties 773
selecting for cable drum 650
reference control stations 774
reference data 27, 39
Reference Data Explorer 37, 70
copying 27
customizing sort sequence within folders
70
overview 37
Reference Electrical Engineer 61, 62, 63
copying power network structures 62
drag-and-drop rules 63
overview 61
reference items
adding 40
battery banks 101
blocks 51, 52
cables 139, 140
circuit components 44, 45
circuits 44
863
Index
control stations 43
converting equipment 102
copying 77
creating project items 125
deleting 79
duplicating 78
generators 99
motors 41
other equipment 87
panels 42, 43
schematics 53
shipped data 39
static electrical equipment 85
transformers 102
refreshing drawings 595
regional standards 59
enabling addional standards 59
relation rules 820
consistency criteria 820
logical expressions 820
relationships 72
relays 112
functions 112
protection 112
renaming items 79, 421
in KKS mode 421
replacing cables 155, 647
report templates 395
common tasks 395
defining items 398
reports 31, 254, 382, 389, 391, 394, 397,
398, 742
adding report macros 398
All Feeder Load Summary (Enhanced)
254
associating registered reports 394
creating for selected items 382
Enhanced All Feeder Load Summary
389
enhanced load summary report 254
macros for report headers 397
registering 391, 742
revisions in registered reports 391
setting preferences 31
shipped reports 382
resistors 78, 79, 85
adding 85
deleting 79
duplicating 78
retrieve data 426
reviewing properties 73
revisions
global revisions 366
864
S
saving 588
drawings 588, 589
settings 596
Tabular Editor 588
templates 588
settings 596
schematic blocks 51, 52
Index
schematics 53, 55, 256, 259, 260, 261,
262, 265, 273, 274, 277, 278, 279, 280,
281, 349, 350, 351, 352, 353, 355, 356,
365, 366, 367, 368, 774, 788
adding revisions 365
annotations 273, 278, 349, 350, 351
annotations and redlining 349
batch generation 278
comparing documents 367, 368
complete symbol file in Catalog Manager
280
entering revisions 261
generating 273, 277
global revisions 366
in AutoCAD 281
in Catalog Manager 279
in MicroStation 281
in SmartSketch 280
including Enhanced SmartLoop reports
277, 278
macros 262
macros in multi-sheet schematics 256
manipulating 355
modifying 261
multi-item 274, 788
multiple sheets 774
multi-sheet 55
opening 279
overview 259
printing 261
redlining 351, 352, 353
renaming 261
saving annotations 279
saving as an external file 261
saving as external document 279
sequencing items 265
typical 53
viewing 356
workflow 260
zooming 356
scoping 450, 453, 454, 456, 457
items 456
projects 450
rules for scoping items 454
scoping items overview 453
using the buffer 457
segments 165
creating 165
segregation levels 628
select all cells in Tabular Editor 606
ordering 619
sorting
865
Index
opening for a PDB 294
opening for Electrical Engineer items
294
opening from Documents folder 294
options 285
overall SLDs 799
overview 283
parallel cables 285
printing 285
redlining 351, 352, 353
removing an item 307
renaming 285
reposition overlapping connectors 731
saving as an external file 285, 295
SmartText label attributes 310
symbol creation guidelines 310
template 291
using custom symbols 305
viewing 356
zooming 356
sizing cables 56, 146, 147, 151, 624, 633,
641
algorithms 151
batch mode 147, 624
individual sizing 146
manual sizing 641
short circuit lookup table data 56
sizing data 633
SLDs
adding revisions 365
Align command 360
aligning drawing objects 359
annotations 349, 350, 351
annotations and redlining 349
based on bus rated voltage 799
batch generation from Electrical Index
291
bus ties with internals 292
comparing documents 367, 368
electrical analysis SLDs 799
entering revisions 285
finding items 304
generating 292
generating from Electrical Engineer 288
generating from Electrical Index 289
generation preferences 30
global revisions 366
inserting legend 304
manual generation 291
modifying 285
object alignment overview 357
opening 293
opening for a PDB 294
866
Index
Project Status dialog box 754, 755
understanding 450
summaries 589
support 606
symbol files 279, 280, 313
complete symbol file for schematic blocks
in Catalog Manager 280
in SmartSketch 280
placing connection points 313
schematic blocks in Catalog Manager
279
symbols 305, 310, 372
inserting in miscellaneous drawings 372
SLD symbols in Catalog Manager 310
using custom symbols in SLDs 305
T
table items 373
bold 373
editing 373
editing properties 374
freezing panes 373
italic 373
table views 594
tables 605
editing properties 373
items 605
layouts 375
new 374
project management 605
properties 76, 605, 607
Tabular Editor 373, 606
filters 378
properties 375
tag selection 69
tapping 104
templates 255, 372, 395, 587, 588
drawings 255, 587, 588
inserting external graphics 372
reports 395
saving 588
terminal strip configuration 332, 333
applying reference configuration 333
defining configuration 333
reference configurations 332
terminal strips 331, 332, 333
applying reference terminal strip
configuration 333
creating in Electrical Index 331
defining terminal strip configuration 333
reference terminal strip configuration
332
terminals 332, 825
U
uncompensated electrical data 214
UPSs 78, 79, 102
adding 102
deleting 79
duplicating 78
V
validations 574, 577
custom 574, 577
implementing 574
variable frequency drives 78, 79, 102
867
Index
adding 102
deleting 79
duplicating 78
properties 72, 74, 75, 76
tables 605
views 75, 375, 595, 597, 605
drawings 596
refreshing 595
settings 596
tables 596, 607
tabular 374
Z
zooming 356, 733
PDB layout design sheets 733
W
Web 606
address 610
forum 606
welding outlets 87
windows 72
wiring drawings 327, 336, 337, 340, 341,
342, 355
applying reference terminal strip
configurations 333
batch cable connection 339
connecting cable sets 340
connecting cables (continuous method)
337
connecting cables (custom method) 336
connecting single conductors 340
continuous cable connection method
337
continuous connection method 337
custom connection method 336
customizing jumper symbols 342
defining connection types 335
disconnecting cable sets 341
disconnecting cables 341
disconnecting conductors 341
finding items in the EI or EE 355
grouping related items 70
jumpering terminals 341
notes on working with drawings 342
opening 342
opening wiring diagrams 342
overview 331
reference terminal strip configurations
332
removing items 327
terminal strips in Electrical Index 331
terminals in Electrical Index 332
wiring project items common tasks 334
World Wide Web 606, 610