You are on page 1of 8

SMP - 7000H

USERS MANUAL

YUMYUNG ENGINEERING CO., LTD.

Table of Contents
1.Introduction ......................................................................................................................1
1.1 Features....................................................................................................................1

2.Product Specifications ..................................................................................................2


3.Front Plate Descriptions ...............................................................................................3
4.System Processing Methods .......................................................................................4
5.RPM & Time Setting Flow chart ..................................................................................5
6.ENG & T/C Voltage Output, Software Group Setting Flow Chart .......................6

YUMYUNG

SMP - 7000H USER MANUAL

1. Introduction
SMP-7000H has been designed by Microprocessor control type, it can
operating have the stability, simple operation, easily expansion and compact view atc.

1.1 Features
1) Stability
- It is reliable operation by Microprocessor control
- Power supply have the noise filter
- PCB has been designed with separate line as like power
line and signal line for EMI protection.
- Unit case has made by aluminium material

2) Simple operation
- It has applied the one- touch operation type with MODE and
ENT key

3) Easily Operation
- It has spare terminal of input/output signal and software margine
also.

4) Compact view (outside)


- It have many functions with compact designed by micom practice.

5) Easily A/S
- It can be changed the trouble PCB only of several PCB's
- Terminal blocks has been designed separately with main unit.

YUMYUNG

SMP - 7000H USER MANUAL

2. Product Specification
ITEM

Specification

Power Source

DC 24V, 20%

Consumption Power

5.04W (Max. 220mA)


Engine RPM Display : FND

Display Method

Relay Output Status Display : LED

Accuracy

FS. 0.2%

Display Range

0 ~ 9999

Setup

Digital Setting

ENG Speed

T/C Speed

INPUT

Power Source for Sensor


Frequency Range

Voltage Output
Frequency Output

Sensor Type: SPS-02 Sensor


(L27/38 : SPS-01 Sensor)

+UB(10 ~ 40V)-1.8V
Square Wave

Teeth & RPM

Teeth: 1EA ~ 500EA


0 ~ 1200 RPM

Sensor Type: KBB Sensor


(Magnetic Pick-up)

Sign wave

RPM

0 ~ 60000RPM (0~2kHz)

ENG

+UB=12V MAX (300mA)

T/C

12V MAX (300mA)

ENG

0~10kHz

T/C

0~2kHz (L27/38: 0~1kHz)

ENG

0 ~ 6V

T/C

0 ~ 6V

ENG

0 ~ 10kHz (+12V, Square Wave)


FET Driver MAX=100V, 500mA

1. Tacho fail (L27/38 Pickup Fail), (L32/40 Pickup Fail)


OUTPUT

2. Safety Start
Relay Driver Output

3. Running
4.Over Speed
5. Fuel Limit (L27/38: Start Limit), (L32/40: RPM)
6. Spare (L27/38: JET SYS), (L32/40: Spare)

Applied Engine

H25/33, H21/32, L27/38, L32/40

Insulation Resistance

Over than 100M

Operating Temperature

-10 ~ +65

Storage Temperature

-25 ~ +70

Operating Humidity

Less than 95% RH (Non Condensing)

Dimension

118(W) X 130(H) X 60(D) (UNIT: mm)

Weight

720g

Case Material

Steel

YUMYUNG

SMP - 7000H USER MANUAL

3. Front Plate Descriptions

Number

Name

Descriptions
SAFE START LED LED is for indication of the condition of ready to start
After input of fail or start of Pick-up sensor, during the
time of safety start, if RPM is not input LED shall be
TACHO FAIL LED

lighted.
(it is for warning to inform of abnormal operation

ENG. Status LED

condition)
ENG RUN LED
OVER SPEED
LED
FUEL LIMIT

RPM Display

Setting Button

LED is for indication of the condition of engine run.


In the condition the speed limit value is established, the
LED is lighted when the speed exceeds the speed limit
value.
LED is for indication of the Fuel limit when engine start.

RPM of engine in running is indicated by digital number


Each Button used for system setup when RPM display for all relay output
and, Time value, ENG. RPM or T/C RPM output voltage change.

Relay Driver

Output

Relay Driver Output terminal and Engine or T/C RPM output terminal.

/Voltage Output

YUMYUNG

SMP - 7000H USER MANUAL

4. System Processing Methods

Engine RPM Processing Method


Frequency (Hz) signal of engine pick-up is transmitted from
pick-up installed at Cam Gear. The proportional value and
calculating method of rotation number (RPM), frequency(Hz) and
voltage (V) are as follows.

ITEM
Hz

H21/32

H25/33

1200(RPM) X 286(Gear) /60sec = 5720(Hz)

1200(RPM) X (282(Gear) /60sec = 5640(Hz)

RPM

0 ~ 1000 RPM

0 ~ 1000 RPM

Output

0 ~ 6V

0 ~ 6V

Note: L23/30 needs 70 cam gears and L28/32 needs 74 cam gears. However,
L23/30 and L28/32 should be calculated with 35 and 37 cam gears respectively.

T/C RPM Processing Method


Frequency (Hz) signal of T/C Speed Pick-up is transmitted from Pick-up
installed at T/C Inside. The proportional value and calculating method of
rotation number (RPM), frequency (Hz) and voltage (V) are as follows.

ITEM

T/C MAX. RPM : 60000

Hz

60000(RPM) X (2Hole) /60sec = 2000(Hz)

RPM

0 ~ 60000 RPM

Output [V]

0 ~ 6V

Note: Number of hole for T/C Pick-up signal in medium size engine is
one.

YUMYUNG

SMP - 7000H USER MANUAL

5. RPM & Time Setting Flow chart


Enter the Setting Mode

Press M key during 5sec


Setup the OVER SPEED

Save the setting value


Mode change

Running RPM Setting


Mode change
Running Delay Time Set-

Setup the Engine Run RPM

Save the setting value


Setup the Engine Run Delay Time

Mode change
Save the setting value
OFF RPM Set-

Setup the Engine Run Off RPM

Mode change
Save the setting value
Safe Start Delay Time SetMode change
Safe Start OFF RPM Set-

Setup the Delay Time

Save the setting value


Setup the OFF RPM

Mode change
Save the setting value
Setup the TACHO FAIL

Save the setting value


Mode change

Setup the FUEL LIMIT

Save the setting value

Exit the Setting Mode

YUMYUNG

SMP - 7000H USER MANUAL

6. ENG & T/C Voltage Output, Software Group Setting Flow Chart

Enter the Setting Mode

Press M key with down key during 5sec

Setup the ENG. Voltage Output Zero

Save the setting value

Mode change

Setup the ENG. Voltage Output Span

Save the setting value

Mode change

Setup the T/C Voltage Output Zero

Save the setting value

Mode change

Setup the T/C Voltage Output Span

Save the setting value

Mode change

Setup the Software Group

Save the setting value

Exit the Setting mode

YUMYUNG