Professional Documents
Culture Documents
Des c r i pti on
Type
Catalog #
Project
Date
Comments
The VT3 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
temperature, humidity and dust or corrosive fumes are present.
Prepared by
Spec i fi c a ti on F ea t u r e s
Construction
Ele ctrica l*
Shielding
VT3
132
232
332
154T5
254T5
354T5
4-7/8"
[123mm]
6-15/16"
[177mm]
Vaportite Industrial
Lam p C onfi gur a ti o n s
Mount ing Da t a
2 LAMP
1 LAMP
X
4-7/8"
[123mm]
4-7/8"
[123mm]
X=1-13/32"
[36mm]
6-15/16"
[177mm]
3 LAMP
X=1-13/32"
[36mm]
Y=2-1/2"
[64mm]
6-5/8"
[168mm]
Y
X=5-3/8"
[137mm]
6-15/16"
[177mm]
Energy Data
X
49-13/16" [1265mm]
4-3/16"
[106mm]
X
4-7/8"
[123mm]
X=1-13/32"
[36mm]
Y=2-1/2"
[64mm]
6-15/16"
[177mm]
Ins ta lla ti on D a ta
MOUNTING
BRACKETS
Furnished
Two per
4' Unit
Four per
8' Unit
Input Watts:
EB Ballast & STD Lamps
132 (30)
232 (61)
154T5 (54)
254T5 (106)
VT3 Series
OPTIONAL CHAIN HANGING SET
(VT2-CHAIN/SET-U)
Includes 6 ft. of chain, 4 large
S-Hooks and 4 small S-Hooks
Order Two (2) Kits for each
8' Fixture
20F (-6C)
33F (0C)
50F (10C)
0.67
0.97
0.99
VT3-232
n/a
n/a
VT3-254
0.73
0.76
0.86
0.90
0.94
VT3-332
n/a
n/a
0.96
0.98
0.98
VT3-354
0.91
0.93
n/a
n/a
n/a
ADF071376
2013-03-13 13:08:09
VT3
Ph otom etr i c s
VT3-232DR-UNVEB81-WL-U
(1) Electronic Ballasts
(2) 32W T8 lamps
2850 lumens
Spacing criterion:
(II) 1.3 x mounting
height, () 1.5 x
mounting height
Efficiency 77.4%
Test Report:
LTL10864.IES
LER =FL72
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.34
VT3-254T5DR-UNV- C a n d e l a
EHT1-WL-U
(1) Electronic Ballasts Angle Along II
1546
(2) 54W T5 lamps
0
1540
4400 lumens
5
1519
10
1483
Spacing criterion:
15
1436
(II) 1.2 x mounting
20
1375
height, () 1.5 x
25
1300
mounting height
30
1215
35
1118
Efficiency 69.7%
40
1012
Test Report:
45
896
50
770
LTL10777.IES
55
634
LER =FL59
60
496
352
Yearly Cost of 1000 65
70
219
lumens, 3000 hrs
75
113
at .08 KWH = $4.05 80
47
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1103
1097
1083
1059
1025
983
932
870
801
725
640
548
451
352
251
155
77
28
6
45
1103
1108
1107
1091
1089
1058
1035
991
952
892
831
753
683
611
550
471
367
290
217
Across
1103
1107
1106
1127
1113
1098
1088
1052
1024
971
920
878
814
771
698
592
513
427
342
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
91
78
67
58
51
45
40
36
32
29
26
91
74
61
52
44
38
33
29
25
22
20
91
70
56
46
39
32
28
24
20
17
15
89
79
71
65
59
54
49
45
42
38
36
89
75
65
57
50
44
39
35
31
28
26
89
72
60
51
43
37
32
28
25
22
19
89
69
55
46
38
32
27
23
20
17
15
20%
50%
50 30 10
30%
50 30 10
50
84
71
61
54
48
42
37
33
30
27
24
79
67
58
51
45
40
36
32
29
26
23
75
64
55
49
43
38
34
30
27
25
22
84
68
57
49
42
36
31
27
24
21
19
84
66
53
44
37
31
27
23
20
17
15
79
65
54
47
40
34
30
27
23
20
18
79
63
51
43
36
30
26
23
19
17
15
10%
30 10
75
62
52
45
39
33
29
26
23
20
18
0%
0
75
60
49
42
35
30
26
22
19
16
14
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
Average
0-Deg
cd/sm
5519
Average
45-Deg
cd/sm
7213
Average
90-Deg
cd/sm
7212
55
65
75
85
5083
4347
3001
1349
6756
6377
6097
5151
7098
7074
6510
6092
%Lamp
15.8
26.5
49.9
73.1
77.4
%Fixture
20.4
34.3
64.5
94.5
100.0
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
73
58
47
40
33
28
24
20
17
15
13
85
90
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
82
74
66
60
55
50
46
42
39
36
33
82
70
60
52
46
40
36
32
29
26
23
82
66
55
46
40
34
29
26
23
20
18
82
63
50
41
35
29
25
21
18
16
14
80
72
64
58
53
48
44
41
38
35
32
80
68
58
51
45
40
35
32
28
25
23
80
65
54
45
39
33
29
25
22
19
17
80
62
49
41
34
29
24
21
18
15
14
45
1546
1525
1548
1514
1509
1487
1446
1396
1315
1267
1174
1081
954
827
771
704
578
432
285
13
Across
1546
1533
1525
1546
1566
1530
1509
1502
1425
1384
1308
1179
1107
1101
1044
936
807
614
431
20%
50%
50 30 10
30%
50 30 10
50
76
65
55
49
43
38
34
30
27
24
22
72
61
53
46
41
36
32
29
26
23
21
69
58
50
44
39
34
31
28
25
22
20
76
62
51
44
38
32
28
25
22
19
17
76
59
48
40
33
28
24
21
18
15
13
72
59
49
42
36
31
27
24
21
18
17
72
57
46
39
33
27
24
20
17
15
13
10%
30 10
69
57
47
41
35
30
26
23
20
18
16
69
55
45
38
32
27
23
20
17
15
13
0%
0
67
53
43
36
30
25
22
18
16
13
12
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
Average
0-Deg
cd/sm
7704
Average
45-Deg
cd/sm
10245
Average
90-Deg
cd/sm
10279
55
65
75
85
7142
6126
4240
2265
9700
8631
9114
7674
9531
10102
10293
8760
Lumens
1253
2112
3985
5908
6137
%Lamp
14.2
24.0
45.3
67.1
69.7
%Fixture
20.4
34.4
64.9
96.3
100.0
Tandem
Blank= 4' Length
8T=8' Length
Series
VT3=Vaportite (Gasketed
Enclosure)
Number of Lamps (3)
1=1 Lamp
2=2 Lamps
3=3 Lamps
(Lamps not included)
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120/277 (2)
UNC=Universal
Voltage 347/480 (6)
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed (4)
Wattage (Length)
32=32W T8 (48")
28T5=28W T5 (48")
54T5=54W T5HO (48") (3)
Lens
DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
DR-50=50% High Impact Additive
DR-100=100% High Impact Additive (Extreme)
NOTES: (1) Ballast type used only if ballast & voltage is chosen. (2) Not available when specifying emergency ballasts, voltage must be specific. (3) EHT2 ballasts are recommended
for ambient temperatures above 102F (40C) 3 Lamp 54W T5HO configurations. (4) Test
switch mounted inside luminaire for all lamp types. (5) Top Hub required when stem
mounting. (6) 2/3 lamp ballast configurations in EB8/PLUS only for T8 UNC version. (7) Use
EHT1 ballast in ambient temperatures below 0F (-18C) on 3 Lamp 54W T5HO configurations. (8) Example: VT3-232DR-UNV-EB81-WL-GT4-U. See stock guide online for stock items.
(9) Order one (1) kit for 4ft. fixture, or two (2) kits for 8ft. fixture.
SH IPPING DATA
Catalog No.
VT3-132 DR-WL
VT3-232 DR-WL
VT3-154T5
VT3-254T5
WL=Wet Location
Label
Packaging
U=Unit Pack
PALC=Job
Pack in
Carton
Options
8L=8 Latches (IP67 Rating),
(4' only)
RIF1=Radio Interference Suppressor
TH=(2) Top Watertite Hubs (5)
TEH=(2) Top & (2) End Watertite Hubs
(all Watertite Hubs have 1/2" Conduit Entry) (5)
BKS=(2) Snap-on Brackets for Chain or
Surface Mount
M4=Specular Reflector
SSL=Stainless Steel Latches
VRS=Vandal Resistant Screws for Latches
GT4=Stock product only (8)
Wt.
16 lbs.
16 lbs.
16 lbs.
16 lbs.
ADF071376
2013-03-13 13:08:09