You are on page 1of 8

PT.

KABELINDO MURNI Tbk

SHIPBOARD CABLE

WIRE AND CABLE MANUFACTURER

No. QCS 00152

No. OSH 00971

No. EMS 00151

Introduction of company

The Companys history was marked by the founding of

PT. Kabel Indonesia

(Kabelindo) in 1972, a foreign invested Company at the time and one of the first cable
manufacturers in Indonesia. In 1979, the Companys ownership was transferred to
Indonesians and names was changed to PT. Kabelindo Murni.
The quality assurance of the products is the main issue that the Company
emphasizes. The electrical cables produced by the Company has passed the Indonesian
National Standard (SNI) and National Power Company Standard (SPLN). The Company
completes several international standards such us : Standard International Electrotechnical
(IEC), Australian Standard (AS), British Standard (BS), Japanese Industrial Standard (JIS) and
Insulated Cable Engineers Association / National Electrical Manufacturers Association (ICEA/
NEMA)
To Support the Companys commitment to quality, the Company has the ISO 9001:2008
OHSAS 18001 : 2007 ISO 14001 : 2004 certificate.

Shipboard Cable
Application: This product is suitable for use in power, control, instrumentation and
communication system of ships and water buildings.
Operating Temperature: Max permissible continuous operating temperature of conductor
850C for EPR insulated shipboard cable;
900C for XLPE insulated shipboard cable.
700C for PVC insulated shipboard cable.
Bending Radius: Permissible bending radius
6D for metal braided armoured cable;
6D for unarmoured cable, D > 25 mm;
4D for unarmoured cable, D 25 mm;
D = Actual outer diameter of cable (mm)
Standard: IEC 60092-series, IEC 60332, IEC 60331 or other standards required by customers.
Packing: Steel/wooden reel, wooden reel or steel reel.

SHIPBOARD CABLE

Certificate

SHIPBOARD CABLE CONSTRUCTION


SHIPBOARD CABLE

Cable Designation
IEC Nomenclature

Type of cables

JIS Nomenclature

CEV90DA/NA

Single core, EP rubber insulated, PVC sheathed, and steel wire


braided cable

(FA-)SPYC

CEV92DA/NA

Single core, EP rubber insulated, PVC sheathed, and steel wire


braided cable with protective covering

(FA-)SPYCY

CEVSA/NA (2, 3, 4, 5, 6 Core)

Double core, EP rubber insulated, and PVC sheathed cable

(FA-)DPY

Three core, EP rubber insulated, and PVC sheathed cable

(FA-)TPY

Four core, EP rubber insulated, and PVC sheathed cable

(FA-)FPY

5core, EP rubber insulated, and PVC sheathed cable

(FA-)5PY

6core, EP rubber insulated, and PVC sheathed cable

(FA-)6PY

Multi core, EP rubber insulated, and PVC sheathed cable

(FA-)MPY

Double core, EP rubber insulated, PVC sheathed and steel wire


braided cable

(FA-)DPYC

Three core, EP rubber insulated, PVC sheathed and steel wire


braided cable

(FA-)TPYC

Four core, EP rubber insulated, PVC sheathed and steel wire


braided cable

(FA-)FPYC

5core, EP rubber insulated, PVC sheathed and steel wire braided


cable

(FA-)5PYC

6core, EP rubber insulated, PVC sheathed and steel wire braided


cable

(FA-)6PYC

Multi core, EP rubber insulated, PVC sheathed and steel wire


braided cable

(FA-)MPYC

Double core, EP rubber insulated, PVC sheathed, and steel wire


braided cable with protective covering

(FA-)DPYCY

Three core, EP rubber insulated, PVC sheathed, and steel wire


braided cable with protective covering

(FA-)TPYCY

Four core, EP rubber insulated, PVC sheathed, steel wire braided


and protective covering cable

(FA-)FPYCY

5core, EP rubber insulated, PVC sheathed, and steel wire braided


cable with protective covering

(FA-)5PYCY

6core, EP rubber insulated, PVC sheathed, and steel wire braided


cable with protective covering

(FA-)6PYCY

Multi core, EP rubber insulated, PVC sheathed and steel wire


braided cable with protective covering

(FA-)MPYCY

CEV90SA/NA (2, 3, 4, 5, 6 Core)

CEV92SA/NA (2, 3, 4, 5, 6 Core)

SHIPBOARD CABLE CONSTRUCTION


SHIPBOARD CABLE

Cable Designation
IEC

Type of cables

JIS

CEVP80DA/NA

Single core, EP rubber insulated, PVC sheathed and steel wire or


copper alloy braided cable with collective screen

(FA-)SPYCS, (FA-)SPYCBS

CEVP82DA/NA

Single core, EP rubber insulated, PVC sheathed, steel wire or copper


alloy braided and protective covering cable with collective screen

(FA-)SPYCYS, (FA-)SPYCBYS

Double core, EP rubber insulated, PVC sheathed and steel wire


braided cable with common shield

(FA-)DPYCS

Three core, EP rubber insulated, PVC sheathed and steel wire


braided cable with common shield

(FA-)TPYCS

Four core, EP rubber insulated, PVC sheathed and steel wire braided
cable with collective screen

(FA-)FPYCS

Double core, EP rubber insulated, PVC sheathed, steel wire braided


and protective covered cable with common shield

(FA-)DPYCYS

Three core, EP rubber insulated, PVC sheathed, steel wire braided


and protective covered cable with common shield

(FA-)TPYCYS

Four core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covering cable with collective screen

(FA-)FPYCYS

Double core, EP rubber insulated, and PCP sheathed cable

(FA-)DPNP

Three core, EP rubber insulated, and PCP sheathed cable

(FA-)TPNP

Four core, EP rubber insulated, and PCP sheathed cable

(FA-)FPNP

CJ/NA

XLPE insulated switch board cable

(FA-)SCP

CV/NA

PVC insulated switch board cable

(FA-)SYP

CHEVP90SA/NA

Multi core, EP rubber insulated, PVC sheathed and steel wire braided
cable with common shield

(FA-)MPYCS

CHEVP92SA/NA

Multi core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covered cable with common shield

(FA-)MPYCYS

CHEVP390SA/NA

Multi core, EP rubber insulated, PVC sheathed and steel wire braided
cable with individual shield

(FA-)MPYC-S

CHEVP392SA/NA

Multi core, EP rubber insulated, PVC sheathed, steel wire braided and
protective covered cable with individual shield

(FA-)MPYCY-S

CHEVP/NA (2, 3, 4, 5, 6 Core)

CHEVP90/NA (2, 3, 4, 5, 6 Core)

CEFSA/NA (2, 3, 4, 5, 6 Core)

Note : For another insulation type, inner sheath and sheathing type by customer request

SHIPBOARD CABLE CONSTRUCTION


SHIPBOARD CABLE

Cable Nomenclature
IEC Nomenclature
Code

Explanation

Code for cable series

C
CK
CH

Shipboard power cable


Shipboard control cable
Shipboard communication cable and signal cable

Code for insulation

E
J
V

EPR
XLPE
PVC

Code for sheath

F
H
PF
PJ
V

CR(SE1)
CSM (SH)
LOSH Non-cross-Linked PO sheath (SHF1)
LOSH Cross-Linked PO sheath (SHF2)
PVC sheath

Code for armour and outer sheath

0
2
5
6
8
9

No outer sheath
PVC outer sheath
Cross- Linked PO oter sheath
Non-cross-linked PO outer sheath
Tinned copper wire braided
Galvanized steel wire braided

Code for other contruction

P
R

Wire or twisted pair with individual


Flexible construction for conductor

Code for flammability

DA
Single cable flame retardant (IEC60332-1-2)
DC
Single flame retardance, low-smoke, halogen free, low toxicity
NC/NSC Fire resistant, low-smoke, halogen free, low toxicity
Bunched cable flame retardant ( IEC60332-3-22)
SA
Bunched flame retardance, low-smoke, halogen and toxicity
SC
Bunched cable flame retardance, low-smoke, halogenfree, low toxicity
NA/NSA Fire resistant, low- smoke, halogen free and low toxicity

JIS Nomenclature
Main use and no. of core

Insulation type

Sheath

Armouring

Single core

EPR

PVC

Steel wire braid

Double core

PVC

PCP

CB

Copper alloy wire braid

Three core

FR-XLPE

Four core

5 core

6 core

Multi core

TT
P

Telephone and instrument


Portable and flexible

FA-

Flame retardant (IEC 60332-3A)

FRT-

Fire resistant (IEC 60331)

FRT(A)- Flame retardant and fire resistant


S

Switch board cable

Covering
Y

PVC

Otherwise
S

Common shield

-S

Individual core and pair shield

Earth wire

SHIPBOARD CABLE CONSTRUCTION


SHIPBOARD CABLE

Product Size Range

Single Core : 1 up to 300 mm


2 Core : 1 up to 185 mm

43 Core : 1 up to 185 mm

Multi Core (5 core ) : 1 2.5 mm

Reference IEC Standard

60092-350 : Shipboard power cables General construction and test requirements


60092-351 : Insulating materials for shipboard and offshore units, power, control, instrumentation,
telecommunication and data cables
60092-352 : Choice and installation of cables for low-voltage power systems
60092-353 : Single and multicore non-radial field power cables with extruded solid insulation for rated
voltage 1 kV and 3 kV
60092-354 : Single and three-core power cables with extruded solid insulation for rated voltage 6 kV
(Um = 7.2 kV) up to 30 kV (Um = 36 kV)
60092-359 : Sheathing materials for shipboard power and telecommunication cables
60092-376 : Cables for control and instrumentation circuits 150/250 V (300 V)

Range Product Supply


Bare Wire (Overhead Conductor)
All Aluminium Stranded Conductor (AAC)
Aluminium Conductor Steel Reinforced (ACSR)
All Aluminium Alloy Conductor (AAAC)
Thermal Aluminium Conductor Steel Reinforced (T-ACSR)
Aluminium Conductor Aluminium Clad Steel Reinforced (ACSR/AS)
Aluminium Conductor Composite Core (ACCC/TW)

SHIPBOARD CABLE

Power Cable
PVC Insulated Power Cable
Low and Medium Voltage XLPE Insulated Power Cable Up to 36 kV
Overhead Cable
All Aluminium Conductor XLPE Insulated Twist Cable (NFA2X)
All Aluminium Conductor Aluminium Alloy Messenger XLPE Insulated (NFA2X-T)
All Aluminium Alloy Conductor XLPE sheath (AAAC-S)
All Aluminium Conductor XLPE Insulated Aluminium Alloy Messenger (NFA2XSY-T)
Shipboard Cable
Building Wire
Control And Instrument Cable
PVC Insulated
XLPE Insulated
Telecommunication Cable
Telephone Cable
RF Cable and Accessories

Bare Conductor Low Voltage Cable Medium Voltage Cable


Instrument Cable Control Cable Shipboard Cable Fire Resistant Cable
Flame Retardant Cable Telephone Cable RF Feeder Cable And Accessories

PT KABELINDO MURNI Tbk


Jln Rawagirang No. 2
Kawasan Industri Pulogadung, Jakarta 13930
INDONESIA

Telp
: +62 21 460 9065 ; +62 21 460 9550
Fax
: +62 21 460 9064 ; +62 21 4604271
Email : sales@kabelindo.co.id
www.kabelindo.co.id

You might also like