Professional Documents
Culture Documents
Integrantes:
Cristbal
Delgado G.
Profesor:
Auxiliar:
Fecha de
Entrega:
ndice
Luca Mosciatti J.
Cesar Pastn
Ignacio Cartes
02/12/13
1. Parte a).....................................................................................................................2
2. Parte b).....................................................................................................................3
3. Parte c).....................................................................................................................4
4. Parte d).....................................................................................................................7
5. Parte e).....................................................................................................................9
6. Parte f)....................................................................................................................11
1. Parte a)
Disear el talud aguas arriba del reservorio para una condicin previa al
llenado, utilizando el baco de Taylor. Considerar un factor de seguridad esttico
mnimo de FS=2.0.
Para el talud de la Figura 1, se puede calcular el valor de N 0 utilizando la
frmula:
FS=
Hc
H
Ns=
Hc
c
2. Parte b)
2
Analice la estabilidad del talud aguas abajo para una condicin previa al
llenado del reservorio utilizando Slope/W.
Utilizando las dimensiones de la Figura 1, y utilizando el programa Slope/W, se
calcularon los factores de seguridad para los dos taludes utilizando los mtodos
Ordinario, Bishop, Janbu, Spencer y Morgenstern-Price. Los resultados se presentan
en la tabla a continuacin.
Tabla 1: Factores de Seguridad para Talud Aguas Abajo previo al llenado
Mtodo
Ordinario
Bishop
Janbu
Spencer
MorgensternPrice
Xcentro
[m]
31,25
31,25
31,25
31,25
31,25
Ycentro
[m]
35,15
35,15
35,15
35,15
35,15
Radio
[m]
27,10
27,10
27,10
27,10
27,10
Factor
Seguridad
1,902
1,991
1,864
1,988
1,988
de
Mtodo
Ordinario
Bishop
Janbu
Spencer
MorgensternPrice
Xcentro
[m]
3
3
3
3
3
Ycentro
[m]
22,2
22,2
22,2
22,2
22,2
Radio
[m]
7,12
7,12
7,12
7,12
7,12
Factor
Seguridad
1,689
1,709
1,706
1,708
1,709
de
3. Parte c)
Analice la estabilidad de los taludes aguas arriba y abajo despus que el
reservorio se llena hasta una altura de 3 m. Si alguno de los taludes no es estable,
proponga una solucin para estabilizarlo. Considere para el anlisis slo la condicin
permanente de flujo y la densidad saturada de los materiales.
Utilizando el anlisis para el reservorio seco utilizado en b), pero cambiando los
valores de la densidad a la saturada, y agregando el anlisis para el reservorio con
agua a una altura de tres metros usando Seep/W, se obtienen los resultados
presentados a continuacin.
Tabla 3: Factores de Seguridad para Talud Aguas Abajo luego del llenado
Mtodo
Xcentro
[m]
Ycentro
[m]
Radio
[m]
Factor
Seguridad
de
3
Ordinario
Bishop
Janbu
Spencer
MorgensternPrice
31,55
32,65
31,55
32,65
32,65
37,35
41,8
37,35
41,8
41,8
27,31
33,79
27,31
33,79
33,79
1,751
1,827
1,723
1,825
1,825
Tabla 4: Factores de Seguridad para Talud Aguas Arriba luego del llenado
Mtodo
Ordinario
Bishop
Janbu
Spencer
MorgensternPrice
Xcentro
[m]
1,5
1,5
0,88
0,88
0,88
Ycentro
[m]
21,25
21,25
23,50
25,75
24,63
Radio
[m]
6,39
6,39
8,74
10,80
9,84
Factor
Seguridad
1,365
1,354
1,399
1,519
1,437
de
Como se puede observar, todos los taludes son estables para todos los anlisis
pues el factor de seguridad es siempre superior a 1. En las figuras 2, 3 y 4 se puede
observar el anlisis cuando existe flujo y el anlisis para los taludes aguas arriba y
aguas abajo en el caso particular del mtodo de Bishop (no se incluyen imgenes
para todos los mtodos porque son prcticamente iguales).
4. Parte d)
Analice los crculos ms crticos encontrados en la parte c) con los mtodos de
Fellenius y Bishop simplificado, utilizando una plantilla de clculo Excel. Compare los
resultados con la parte c) y comente.
Los valores de ,W, l y u para cada dovela se obtienen utilizando los valores
entregados por GeoStudio al momento de realizar el anlisis. Se utilizarn 15 dovelas
para realizar el clculo. Utilizando estos valores, se puede obtener el factor de
seguridad utilizando las frmulas deducidas en clases para cada uno de los mtodos,
los resultados se resumen en las Tablas 5, 6, 7 y 8.
Tabla 5: Datos de las dovelas aguas abajo
Dovela
li [m]
i []
1
2
3
3.98
2.66
2.47
2.33
2.22
2.14
2.07
2.03
1.99
10
11
12
13
14
15
1.96
1.95
1.94
1.94
1.94
1.97
49.8
43.3
38.2
8
33.5
8
29.1
4
24.8
8
20.7
6
16.7
5
12.8
3
8.96
5.14
1.34
-2.46
-6.27
-10.1
Wi
[kN/m]
66.52
117.17
145.9
u
[kN/m2]
-24.28
4.09
16.28
165.73
19.56
178.14
24.52
184.15
42.9
184.45
25.76
179.55
29.38
169.8
36.44
155.47
136.74
113.7
86.442
54.884
19.023
28.91
20.99
16.87
8.25
3.73
-5.95
FS Bishop
FS
Fellenius
1.535386
138
1.477590
208
Dovela
li [m]
ai []
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0.34
0.35
0.35
0.36
0.37
0.32
0.34
0.35
0.37
0.46
0.5
0.55
0.63
0.78
1.16
15.35
18.42
21.56
24.78
28.06
31.19
34.15
37.22
40.43
44.13
48.44
53.15
58.46
64.78
73.49
Wi
[kN/m]
1.4
4.14
6.77
9.28
11.67
11.64
13.16
14.58
15.88
18.74
16.79
14.5
11.74
8.25
3.14
u
[kN/m2]
27.89
22.17
22.17
21.82
19.94
13.96
13.96
14.42
9.51
9.89
3.79
-0.63
-10.43
-19.09
-23.72
FS Bishop
FS
Fellenius
1.209249
13
1.201061
354
Con estos resultados se puede realizar una comparacin entre los factores de
seguridad obtenidos utilizando GeoStudio y los obtenidos utilizando las frmulas
deducidas en clases.
Tabla 9: Comparacin aguas abajo
Mtodo
Excel
GeoStudi
o
Diferenci
a
Bisho
p
1.54
1.82
Felleni
us
1.48
1.75
0.25
0.27
Mtodo
Bisho
p
Felleni
us
8
Excel
GeoStudi
o
Diferenci
a
1.21
1.35
1.20
1.37
0.14
0.17
5. Parte e)
Repita el anlisis con el mtodo de Bishop simplificado del punto anterior
considerando un coeficiente ssmico horizontal k h=0.1. Compare el factor de
seguridad de ambos casos.
De igual manera que en la parte d) se obtienen los datos de GeoStudio pero
adicionalmente se mide la distancia vertical entre el punto en el centro de la base de
cada dovela y el centro del radio del crculo de falla.
Tabla 11: Datos dovelas aguas abajo
Dovela
i []
li [m]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
3.98
2.66
2.47
2.33
2.22
2.14
2.07
2.03
1.99
1.96
1.95
1.94
1.94
1.94
1.97
49.8
43.3
38.28
33.58
29.14
24.88
20.76
16.75
12.83
8.96
5.14
1.34
-2.46
-6.27
-10.1
Wi
[kN/m]
66.52
117.17
145.9
165.73
178.14
184.15
184.45
179.55
169.8
155.47
136.74
113.7
86.442
54.884
19.023
u
[kN/m2]
-24.28
4.09
16.28
19.56
24.52
42.9
25.76
29.38
36.44
28.91
20.99
16.87
8.25
3.73
-5.95
di [m]
23.67
25.81
27.35
28.93
29.99
30.98
31.78
32.48
32.98
33.28
33.62
33.76
33.76
33.62
33.41
FS Bishop
1.171978
601
Dovela
li [m]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0.34
0.35
0.35
0.36
0.37
0.32
0.34
0.35
0.37
0.46
0.5
0.55
0.63
0.78
1.16
i []
15.35
18.42
21.56
24.78
28.06
31.19
34.15
37.22
40.43
44.13
48.44
53.15
58.46
64.78
73.49
Wi
[kN/m]
1.4
4.14
6.77
9.28
11.67
11.64
13.16
14.58
15.88
18.74
16.79
14.5
11.74
8.25
3.14
u
[kN/m2]
27.89
22.17
22.17
21.82
19.94
13.96
13.96
14.42
9.51
9.89
3.79
-0.63
-10.43
-19.09
-23.72
di [m]
6.16
6.05
5.93
5.83
5.63
5.46
5.26
5.06
4.83
4.57
4.26
3.77
3.17
2.62
1.8
FS Bishop
1.036834
479
Sismicida
d
No
Si
Factor
Seguridad
1.54
1.17
de Diferenci
a
0.37
Sismicida
d
No
Si
Factor
Seguridad
1.21
1.04
de Diferenci
a
0.17
En general se obtiene que los factores de seguridad son todos mayores a 1.0,
sin embargo, para el talud aguas arriba considerando sismicidad este es muy
cercano a 1, por lo que podra ser necesario un rediseo, como variar el ngulo beta.
10
6. Parte f)
Despus de comenzar la operacin del reservorio, se requiere construir un camino en
la parte inferior del talud principal. Para ello se necesita remover material hasta
alcanzar una distancia L desde la base del talud principal (ver figura). Proponga una
solucin que asegure un factor de seguridad esttico mnimo FS=2.0 para la nueva
configuracin.
Como nuestro factor de seguridad fue solo un poco mayor a 1. No se puede
cumplir el factor de seguridad FS=2 para la construccin del camino si se le hace un
corte vertical en la base con tal de que quede una horizontal de 7 metros. Tampoco
se cumple si se sacan capas variando as el , puesto que para este caso solo es
posible ir aumentando el ngulo lo que lleva a una disminucin del FS. Se pens
hacerlo de manera escalonada, pero tampoco se lleg al factor demandado.
Para lograr el factor demandado se pens en la instalacin de un muro. Para
este se consider una densidad del hormign hor=25 [Kn/m3].
Para estar seguro de que se cumploa el factor de seguridad igual a 2, nos
dimos la situacin mas critica de forma tal que el clculo sea ms simple y estar
seguro que para la situacin real se cumple lo pedido. Para eso solo se trabajo con el
c de la arcilla 1 y con toda la masa del talud, (no consideramos el suelo que se
remueve para el camino). Con estas condiciones nos quedaron los siguientes datos:
-
u = 125.65 [kN/m2]
kh = 0.1
= rea hormign
FS=
11