Electrical Wiring Diagram Symbols commonly found in HVAC wiring


diagrams
High Voltage, Factory Wired
Low Voltage, Factory Wired
High Voltage, Field Wired
Low Voltage, Field Wired
High Pressure Switch,
Normally Closed
Opens on increase (rise)/Closes on decrease (drop)
(vacuum & pressure activated)
Low Pressure Switch Normally Open Closes on increase
(rise)/Opens on decrease (drop) (vacuum & pressure activated)

Cooling Thermostat
Normally Open
Closes on increase (rise)/Opens on decrease (drop)
(temperature activated)

Heating Thermostat
Normally Closed Opens on increase (rise)/Closes on
decrease (drop)
(temperature activated)

High Liquid Level Switch


Normally Closed Opens on increase (rise)/Closes on
decrease (drop)
(liquid level activated)

Low Liquid Level Switch


Normally Open Closes on increase (rise)/Opens on
decrease (drop)
(Liquid Level activated)

Flow Switch (positive)


Normally Open
Closes on flow or movement
(air, water, liquid flow or movement)

Flow Switch (negative)


Normally Closed
Opens on flow or movement
(air, water, liquid flow or movement)

Normally Open Contacts

Normally Closed Contacts

Disconnect Switch

Magnetic Circuit Breaker


Series Trip

Thermal Circuit Breaker


Series Trip

Normally Open
Spring Return
Limit Switch

Normally Closed
Spring Return
Limit Switch

Held Closed
Spring Return
Limit Switch
Held Open
Spring Return
Limit Switch

Neutral Position
Spring Return
Limit Switch

Maintained Position
Limit Switch

Selector Switch

Slide Switch

Cam Activated Switch

Cam Activated Swtich

Single Pole Single Throw Switch

Single Pole Double Throw Switch

Single Pole Double Throw 3 Position Switch

Double Pole Double Throw Switch

Push Button
Normally Open
Single Circuit
Momentary, Spring Return

Push Button
Normally Closed
Single Circuit
Momentary, Spring Return

Momentary Push Button


Double Circuit
Momentary, Spring Return

Maintained Push Button


Double Circuit

Normally Opened
Energized Time Contact
Contact
action retarded when coil is
ENERGIZED

Normally Closed Energized


Time Contact
Contact action is retarded
when coil is ENERGIZED

Normally Open De-energized


Time Contact
Contact action is retarded
when coil is DE-ENERGIZED

Normally Closed De-energized


Time Contact
Contact action is retarded
when coil is DE-ENERGIZED

Fixed Resistor
Glow Coil
Strip Heater

Variable Resistor

Tapped Resistor

Thermistor

Heater type Resistor

Transformer (variants)

Capacitor

Coil (variants)

Fuse

Fusible Link

Ground Connection

Light

Multiple Conductor Cable

Thermocouple

Thermal Overload

Bi-Metal Switch

Connectors

Electrode
Ignitor

Crank Case Heater

Meter
* denotes type

Variable Inductor
ch

Fixed Inductor
itch
Solenoid

Multi Pole Double Throw Switch

Multi Pole Single Throw Switch

Electrically Operated Switch


* Indicates magnetic coil,motor, or
thermal element

Foot Switch
Normally Open

Foot Switch
Normally Closed

Auto Transformer

Current Transformer

Variable Transformer

Transformer - Auto Adjustable


Tapped

Fixed Iron Core Coil

Fixed Air Core Coil

Adjustable Iron Core Coil

Adjustable Air Core Coil

Motor
Single Phase
2 Lead

Motor Single Phase 3 Lead

Motor 3 Phase 3 Lead

Motor 3 Phase 6 Lead


Dual Windings

Bi-Metallic Thermal Overload

Bi-Metallic Thermal Overload


with heater

Microphone

Diode

Headset
Headset

Horno r siren

Horn or Siren
Buzzer or bell

Push to Test Lamp

Push to Test Lamp


Shielded Cable