Professional Documents
Culture Documents
LOW CURRENT
PHOTOELECTRIC BEAM SENSOR
PXB-100SW
DRIP-PROOF HOUSING
Prevents rain and snow from streaming down the front side of
housing, helping to avoid false alarm.
WIDE BEAM
The pitch between upper and lower beam is widened more than
old models. False alarm by birds and falling leaves reduces
drastically.
TARGET COLOR
50% less than remaining models. The battery size may reduce,
wiring diameter may lessen, installation cost may decrease.
9HUWLFDOO\FRPSDUHGZLWKSUHYLRXVYHUVLRQ,WPD\DGDSWWR
the slope installation flexibly.
ECOLOGY
INSECT/WATER PREVENT
ANTI-BIRD SPIKE
LIGHTNING PROTECTION
Keeps birds and small animals away from the sensor, helping to
reduce false alarms.
4.49"(114 mm)
2.52"
(64 mm)
2.87"(73 mm)
3.35"(85 mm)
5.98"(152 mm)
4-0.16"
Compatible with screws
(4-4 mm)
0.94"(24 mm)
2-0.16"
Compatible with screws
1.57"(400 mm)
7.95"(202 mm)
Pole cover
(Optional accessory)
9.06"(230 mm)
3.29"(83.5 mm)
2-0.16"
Compatible with screws
(2-4 mm)
0.94"(24 mm)
4.76"(121 mm)
9.45"(240 mm)
2-0.79"
(20 mm)
7.62"(193.5 mm)
17.72"(450 mm)
Wiring hole
4.29"(109 mm)
(2-4 mm)
2.36"(60 mm)
Wiring hole 0.51"0.31"
(Knockout: 2 locations)
SPECIFICATIONS
Detection line
Model
Approx. 8ft (2.4m)
2.68"
(68 mm)
4.45 (113mm)
7.24 (184mm)
Detection system
Protection distance
Current consumption
1 (During armed)
2 (During beam alignment)
TRANSMITTER
RECEIVER
Alarm output
1
2
Power input
Power input
5 to 30V DC (polarity)
5 to 30V DC (polarity)
Current consumption
5 to 8VDC : 3.7mA
10 to 30VDC : 5.2mA
Current consumption
5 to 8VDC : 2.3mA
10 to 30VDC : 3.1mA
Alarm output
Environmental output
Tamper output
3
4
7
8
Receiver
Infrared beam
3300' (1000 m)
0.05 sec. to 0.7 sec. (Variable at pot)
Response time
4.45 (113mm)
Transmitter
PXB-100SW
Near infrared pulsed beam interruption system
(TR-RE 4 beam simultaneous interruption)
Tamper output
30V (AC/DC) 0.1A
No-voltage contact : b contact
Built-in contact protection resistance
Environmental output
Tamper output
5 to 12VDC (polarity)
10 to 30VDC
5 to 8VDC
Transmitter Max : 3.7mA 1 Transmitter Max : 5.2mA 1
Max : 8.2mA 2
Max : 9.4mA 2
Receiver Max : 2.3mA 1 Receiver Max : 3.1mA 1
Max : 10.0mA 2
Max : 10.7mA 2
Dry contact relay output form N.C/N.O swithable
Contact action : Interruption time (Min.2sec.)
Contact capacity : 30V (AC/DC) 1A (resistive load) Protective resistor
Dry contact relay output form N.C/N.O swithable
Action : Activated when weather condition gets worse
Contact capacity : 30V (AC/DC) 1A (resistive load) Protective resistor
Dry contact relay (N.C.)
Action : Activated when cover is detached
Contact capacity : 30V (AC/DC) 0.1A (resistive load)
Protective resistor
Alarm LED
Attenuation LED
DC6V
2100ft.( 640m)
3300ft.(1000m)
4000ft.(1200m)
5100ft.(1550m)
6400ft.(1950m)
8400ft.(2560m)
DC12V
DC24V
When 2 or more units are connected, the wiring distance is calculated as follows :
[Above value/number of units]
Functions
Mounting positions
Outdoor, Indoor
65
IP rating
Terminals
Wiring
Weight
Appearance
Please note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary or a crime preventing device.
TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge
by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
In Japan
In the U .S.
In Australia
In the U.K.
h t t p: / / www.ta k e x - e n g .c o .jp /
ht t p: / / w w w . t akex. com
ht t p : / / w w w . t akexeurope. com
LEAF14-03R48-1