1. Relay Function
Blank: General-purpose
7
5. Terminals
S:
Plug-in
2. Number of Poles
1:
1 pole
2:
2 poles
6. Classification
Blank: General-purpose
N:
LED indicator
D:
Diode
ND:
LED indicator and diode
NI:
LED indicator with test button
NDI:
LED indicator and diode with test button
3. Contact Form
Blank: SPDT
4. Contact Type
Blank: Single
Ordering Information
List of Models
Classification
Enclosure
rating
Coil ratings
General-purpose
LED indicator
Plug-in terminal
AC/DC
Unsealed
DC
Contact form
SPDT
DPDT
G2R-1-S
G2R-2-S
G2R-1-SN
G2R-2-SN
G2R-1-SNI (S)
G2R-2-SNI (S)
G2R-1-SD
G2R-2-SD
G2R-1-SND
G2R-2-SND
G2R-1-SNDI (S)
G2R-2-SNDI (S)
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-E and P2RF-S. The Relays bear the CE Marking.
2. Refer to Connecting Sockets, below, for applicable Socket models.
3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
G2R-@-S
Accessories (Order Separately)
Connecting Sockets
Track/surface-mounting Socket
1 pole
G2R-1-S(N)(D)(ND)(NI)(NDI)
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
Back-mounting Socket
Screw terminal
Terminals
Model
P2RF-05-E
P2RF-05
PCB terminals
P2R-05P, P2R-057P
Solder terminals
P2R-05A
P2RF-08-E
P2RF-08
PCB terminals
P2R-08P, P2R-087P
Solder terminals
P2R-08A
Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Model
P2CM-S
Nameplate
Socket Bridge
Mounting Tracks
Applicable Socket
Description
Model
Mounting track
End plate
PFP-M
Track-connecting Socket
Back-connecting Socket
Spacer
PFP-S
Mounting plate
P2R-P*
* Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
Coil Ratings
Rated current*
Rated voltage
50 Hz
AC
60 Hz
Armature
ON
24 V
43.5 mA
37.4 mA
253
0.81
1.55
110 V
9.5 mA
8.2 mA
5,566
13.33
26.83
120 V
8.6 mA
7.5 mA
7,286
16.13
32.46
230 V
4.4 mA
3.8 mA
27,172
72.68
143.90
240 V
3.7 mA
3.2 mA
30,360
90.58
182.34
Rated voltage
DC
Coil
resistance*
Rated current*
Coil
resistance*
Armature
ON
6V
87.0 mA
69
0.25
0.48
12 V
43.2 mA
278
0.98
2.35
24 V
21.6 mA
1,113
3.60
8.25
48 V
11.4 mA
4,220
15.2
29.82
Must
operate
voltage
Must
release
voltage
Max.
voltage
% of rated voltage
80% max.
30% max.
Must
operate
voltage
Must
release
voltage
110%
Max.
voltage
% of rated voltage
70% max.
15% min.
110%
Power
consumption
(approx.)
0.9 VA at 60 Hz
Power
consumption
(approx.)
0.53 W
* The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%.
G2R-@-S
Contact Ratings
Number of poles
1 pole
Load
Resistive load
(cos = 1)
Inductive load
(cos = 0.4; L/R = 7 ms)
Resistive load
(cos = 1)
2 poles
Inductive load
(cos = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
10 A
5A
10 A
2,500 VA,
300 W
100 mA at 5 VDC
5A
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
10 mA at 5 VDC
Characteristics
Item
1 pole
2 poles
Contact resistance
100 m max.
15 ms max.
Max. operating
frequency
Mechanical:
Electrical:
Insulation resistance
Dielectric strength
Vibration resistance
Destruction:
Malfunction:
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Mechanical:
Endurance
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Ambient temperature
Operating:
Ambient humidity
Operating:
5% to 85%
Weight
Approx. 21 g
Approved Standards
UL 508 (File No. E41643)
Model
Contact
form
Coil ratings
G2R-1-S SPDT
5 to 110 VDC
6 to 240 VAC
G2R-2-S DPDT
IEC/VDE (EN61810)
Contact ratings
Operations
Contact
form
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
1 pole
100 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
2 poles
100 x 103
Contact
form
Coil ratings
G2R-1-S SPDT
5 to 110 VDC
6 to 240 VAC
G2R-2-S DPDT
Coil ratings
Contact ratings
Operations
LR
Contact ratings
Operations
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
Number
of poles
Coil ratings
Contact ratings
Operations
1 pole
5 to 110 VDC
6 to 240 VDC
100 x 103
2 poles
5 to 110 VDC
6 to 240 VDC
100 x 103
G2R-@-S
Engineering Data
Maximum Switching Power
Plug-in Relays
G2R-2-S
G2R-1-S
100
AC inductive load
(cos = 0.4)
AC resistive
load
10
DC resistive
load
DC inductive load
(L/R = 7 ms)
0.1
10
100
100
AC resistive
load
DC resistive
load
0.1
1000
AC inductive load
(cos = 0.4)
10
DC inductive load
(L/R = 7 ms)
10
100
1000
Endurance
Plug-in Relays
G2R-2-S
10,000
5,000
1,000
250-VAC/30-VDC
resistive load
500
100
50
G2R-1-S
5,000
1,000
500
100
250-VAC
50 inductive load
(cos = 0.4)
DC coil
AC coil
G2R-@-S
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G2R-1-S
29 max.
13 max.
20
35.5 max.
4.75
7.5
0.5
24V
1
DC
5.2
17.5
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI (S)
G2R-2-SD, G2R-2-SND, G2R-2-SNDI (S)
13 max.
2.5
35.5 max.
7.4
8.9
2.4
6.2
20
29 max.
0.5
G2R-2-SD (DC)
5
19.4
G2R-@-S
Track/Surface Mounting Sockets
38.2 max.
P2RF-05-S
Terminal Arrangement
(Top View)
36.5 max.
11
32.6
14
27.6
12
92.0 max.
Standard model
35.4
24.5
22.6
(5.3)
28.5
18.0 max.
A1 A2
32.6
Terminal Arrangement
(Top View)
38.2 max.
P2RF-08-S
36.5 max.
21 11
24 14
32.6
27.6
22 12
(3.4)
Standard model
35.4
92.0 max.
24.5
22.6
A1 A2
(5.3)
28.6
18.0 max.
32.6
Insulating coating
L
1.2 dia. conductor (See note 1.)
14
16.8
40.35
36
G2R-@-S
Terminal Arrangement
(Top View)
P2RF-05-E
Five, M3.57
48 max.
(14)
39.5
35.5
85.5 max.
Mounting Holes
(for Surface Mounting)
3.2-dia.
hole
(11)
2
(12)
39.50.1
3.5-dia.
hole
M3 or
3.5-dia.
hole
(A1)
(A2)
11.5
61 max.
16.0 max.
P2RF-08-E
2
Terminal Arrangement
(Top View)
1.5
Eight, M38
48.0 max.
Mounting Holes
(for Surface Mounting)
39.5
(21)
(22)
(24)
7
5
2
4
(11)
(12)
(14)
3.2-dia.
hole
35.5
85.5
max.
39.50.1
3.5-dia. hole
(A1)
(A2)
5
61.0
max.
M3 or
3.5-dia.
hole
11.5
16.0 max.
P2RF-05
Terminal Arrangement
(Top View)
Five, M3.5 x 8
4-dia. holes
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
300.05
19.5
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
P2RF-08
2
7
Eight, M3.5 x 8
4-dia. holes
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
300.05
19.5 max.
19.5
30 max.
54 max.
M3 or 3.2-dia.
hole
G2R-@-S
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@-E
P2RF-@
62.0
66.5
70.5
67.0
P2RF-@-S
72.0
65.0
28.6
(5.30)
Back-connecting Sockets
P2R-05P (1-pole)
4
Terminal Arrangement
(Bottom View)
14.5 max.
Mounting Holes
Tolerance: 0.1
4
6
4.5
35.5 max.
15
Five,
1.6-dia.
holes
4.5
1.2
4
15
3.5
4
1.5
(5)
4
7
36.5 max.
P2R-08P (2-pole)
4
0.3
14.5 max.
Terminal Arrangement
(Bottom View)
Mounting Holes
7.5
5
5
35.5 max.
20
1
5
5
20
2.8
1.5
(4.3)
7.5
Terminal plate thickness: 0.3
36.5 max.
G2R-@-S
P2R-05A (1-pole)
14.5 max.
1.2
0.3
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
13.60.1
6
36.5 max.
P2R-08A (2-pole)
30.50.2
14.5 max.
1.2
0.3
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.6
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
Terminal plate thickness: 0.3
P2R-057P
0.7
14 max.
8.7
16.4
10.4
36.5 max.
Terminal Arrangement
(Bottom View)
Mounting Holes
40.1
Five,
1.6-dia.
holes
60.1
37 max.29.6
4.50.1 150.1
8.7
40.1
5
7.4
70.1
41 max.
P2R-087P
14 max.
7.5
Terminal Arrangement
(Bottom View)
16.4
1
10.4
Mounting Holes
7.5
37 max. 29.1
Eight,
1.3-dia.
holes
5
5
20
7.4
8.9
(8.1)
41 max.
G2R-@A
G2R-@7P
G2R Relay
G2R Relay
44.5
P2R-_P
Socket
47.5
38.0
P2R-_A
Socket
G2R-@-S
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16
7.30.15
4.5
4.5
15
25
25
25
25
10
10
1,000 (500)
350.3 27
270.15
350.3
15 (5)
15
25
25 15
25
25
10
10
24
29.2
1.5
1,000
End Plate
Spacer
10
6.2
PFP-M
PFP-S
16
12
1.8
1
50
1.8
11.5
10
M4 x 8 pan
head screw
35.5 35.3
34.8
44.3
1.3
4.8
16.5
Precautions
Cation
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
10
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRONs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company