You are on page 1of 29

PT.

VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 1 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

WRITTEN PRACTICE FOR QUALIFICATION &


CERTIFICATION OF NDE PERSONNEL

DOCUMENT
REVISION NO.

Prepared by

Name

: Eldi Misroza

: VPS - WP - 01
: 00

Reviewed by

Name

: Alamsyah

Position : Operation Manager

Position : General Manager

Date

Date

: 31 May, 2013

: 31 May, 2013

Reviewed and Approved by

Name

: Adi Padmo

Position : ASNT NDT LEVEL III


Cert. No. 126596
Date
: 31 May, 2013

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 2 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

SUMMARY OF REVISION SHEET

This page is a record of all revisions of the written practice and the following revision (s) has (have) been
made to this written practice.

REV.

DATE

PAGE

00

31 May, 2013

All pages

BRIEF OF REVISION
First Issue

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 3 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

Daftar Isi
Par.
1
2
3
4
5
6
7
8
8.1
8.2
8.3
8.3.1
8.3.2
8.3.3

Uraian
Tujuan
Ruang Lingkup
Reference Documen
Definisi Definisi
Tingkat Kualifikasi dan Tanggung
Jawab
Persyaratan Pendidikan, Training
dan Pengalaman
Program Pelatihan
Pengujian
Administrasi dan penilaian
Pengujian Penglihatan
Rincian dari Pengujian
Ujian General Level I dan Level II
(tertulis)
Ujian Spesifik Examination Level I
dan Level II (Tertulis)
Ujian Praktek Level I dan Level II

8.3.4
8.4
9
10

Pengujian untuk Level III


Ujian - ulang
Sertifikasi

11
12
13
14

Interupsi Pelaksanaan
Re-sertifikasi
Pemutusan
Pembaruan
Table 1A Initial Training and
Experinces
Table 1B Training Awal dan
Pengalaman untuk NDT Level II
Limited Certification
Table II - Jumlah Minimum
Pertanyaan Ujian
Exhibit - A - Eye Examination
Record
Exhibit B NDE Personnel
Certificate
Exhibit C Training Course
Syllabus
Shade Gray chart

Technical Performance Evaluation

Table of Content

Par.
1
2
3
4
5

Description
Purpose
Scope
Reference Documents
Definitions
Levels of Qualification and
Responsibility
Education, Training and
Experience Requirements
Training Program
Examinations
Administration and Grading
Vision Acuity Examination
Detail of Examinations
General Examination Level I and
II (written )
Specific Examination Level I and
Level II ( Written )
Practical Examination Level I &
Level II
Examination for Level III
Re-examination
Certification
Technical Performance
Evaluation
Interrupted Service
Re-certification
Termination
Reinstatement
Table 1A Initial Training and
Experinces
Table 1B - Initial Training and
Experience Level for NDT
Level II Limited Certification
Table II - Minimum Number of
Examination Questions
Exhibit - A - Eye Examination
Record
Exhibit B NDE Personnel
Certificate
Exhibit C Training Course
Syllabus
Shade Gray chart

6
7
8
8.1
8.2
8.3
8.3.1
8.3.2
8.3.3
8.3.4
8.4
9
10
11
12
13
14

Page
4
4
4
4
6
7
9
10
10
11
11
11
12
12
12
13
14
15
15
16
16
17
18
19

19
20
21
22 ~ 28
29

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 4 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


1

Tujuan
1
a. Written practice ini menetapkan cara
mengontrol dan persyaratan administrasi
untuk kualifikasi dan sertifikasi personnel
NDE. Semua level personnel dalam NDE
harus dikualifikasi dengan written practice
ini.
b. Procedure ini terdiri dari versi Enggris dan
Indonesia, jika ada konflik antara keduanya
maka versi Enggris yang dipakai.

Purpose
a. This written practice establishes the
control and administrative requirements
for the qualification and certification of
NDE personnel. All levels of NDE
personnel shall be qualified in accordance
with this written practice.
b. This procedure consists of English and
Indonesian versions, shall there is conflict
between these versions the English
version shall govern.

Ruang Lingkup
2
Qualifikasi
dan
sertifikasi
ditujukan
untuk
a.
semua Personnel NDE yang bekerja untuk
PT. VERONIKA PRIMA SANITA.
b. Sertifikasi NDE Personnel untuk PT.
VERONIKA PRIMA SANITA berlaku
hanya jika personnel masih dipekerjakan
oleh PT. VERONIKA PRIMA SANITA
saja.
c. Metode yang termasuk dalam Written
practice adalah PT, MT , UT dan RT

Scope
a. Qualifications and certifications are
addressed to all NDE personnel working
for PT. VERONIKA PRIMA SANITA.
b. NDE Personnel certifications for the PT.
VERONIKA PRIMA SANITA are valid
only when the personnel being employed
by PT. VERONIKA PRIMA SANITA.

Reference Documen
3
The ASNT Recommended Practice No.
SNT-TC-1A, 2011 edition.

Reference Documents
The ASNT Recommended Practice No.
SNT-TC-1A, 2011 edition.

4
4.1

Definisi Definisi
ASNT:
American
Society
for
Nondestructive Testing
Certification:
Bukti
tertulis
dari
kualifikasi tersebut.
Certifying
Authority:
GENERAL
MANAGER dari PT. VERONIKA PRIMA
SANITA
Certifying Agency: The PT. VERONIKA
PRIMA SANITA.
Closed Book Examination: Ujian yang
dilaksanakan tanpa adanya materi referensi
kecuali materi tersebut memang disediakan
atau untuk ujian.
Comparable: Persamaan atau ekivalensi
level dari tanggung jawab dan tingkat
kesulitan NDE yang ditentukan oleh
Level III PT. VERONIKA PRIMA
SANITA.

Definition
ASNT:
American
Society
for
Nondestructive Testing
Certification: written testimony of
qualification.
Certifying Authority:
GENERAL
MANAGER of PT. VERONIKA PRIMA
SANITA
Certifying Agency: The PT. VERONIKA
PRIMA SANITA.
Closed Book Examination: an examination
administrated without access to reference
material except for material supplied with
or in the examination.
Comparable: being at an equivalent or
similar level of NDE responsibility and
difficulty as determined by PT.
VERONIKA PRIMA SANITA Level III

4.2
4.3

4.4
4.5

4.6

4
4.1
4.2
4.3

4.4
4.5

4.6

c. The methods included in this Written


practice are PT, MT , UT and RT.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 5 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


4.7

Documented : Kondisi yang ditulis dalam 4.7


suatu format.

Documented: the condition of being in


written form.

4.8

Employer : PT. VERONIKA PRIMA


SANITA.
Experience:
aktifitas
aktifitas
pekerjaan yang dilaksanakan pada
metode
NDE
tertentu
dibawah
pengarahan supervisi yang berkualifikasi
termasuk performance metode NDE dan
berhubungan dengan aktivitas 2, tetapi
tidak termasuk waktu mengatur program
training.
Certifikasi terbatas : Nondestructive test
method bisa di kelompokkan lebih kecil
kedalam disiplin atau tehnik tertentu untuk
memenuhi kebutuhan spesifikasi dari PT.
VERONIKA PRIMA SANITA; ini juga
Level II, tapi dengan scope terbatas.
Non-destructive Testing (NDT): Proses
yang melibatkan kegiatan inspeksi,
pengujian, atau pengevaluasian dari cacat
material,
properti
dan
masalah
permesinan tanpa harus merusak ataupun
menghancurkan kegunaannya.
Outside Agency: Perusahaan atau
personnel yang menyediakan jasa NDE
Level III dan yang kualifikasinya untuk
jasa ini telah direview dan disetujui oleh
GENERAL
MANAGER
dari
PT.
VERONIKA PRIMA SANITA.

4.8

Employer : PT. VERONIKA PRIMA


SANITA.
Experience:
work
activities
accomplished in specific NDE method
under the direction of qualified
supervision including the performance
of NDE method and related activities,
but does not include time spent
organizing the training program.

Kualifikasi: Demonstrasi keahlian dan


pengetahuan, disertai pelatihan dan
pengalaman yang disyaratkan sehingga
personal mampu melakukan tugas pada
kerjaan yang spesifik dengan benar.
Tehnik : adalah katagori dalam metode
NDT; misalnya, ultrasonic, ultrasonic
thickness testing.
Training: Program yang terorganisasi
untuk memberi pengetahuan dan keahlian
yang dibutuhkan untuk kualifikasi.
Written Practice: Prosedur tertulis yang
disusun oleh PT. VERONIKA PRIMA
SANITA
secara
detail
tentang
persyaratannya untuk kualifikasi dan
sertifikasi Personnel NDE.

4.13

4.9

4.10

4.11

4.12

4.13

4.14

4.15

4.16

4.9

4.10

4.11

4.12

4.14

4.15

4.16

Limited Certification: Nondestructive test


method may be further subdivided into
limited disciplines or techniques to meet
specific PT. VERONIKA PRIMA
SANITAs needs; these are Level II
certifications, but to limited scope.
Non-destructive Testing (NDT): a
process that involves the inspection,
testing, or evaluation of materials
discontinuities, properties and machine
problem without further impairing or
destroying the parts serviceability.
Outside Agency: a company or
personnel who provides NDE Level III
service and whose qualifications to
provide these services have been
reviewed and approved by the PT.
VERONIKA
PRIMA
SANITAs
GENERAL MANAGER.
Qualification: demonstrated skill and
knowledge, along with documented
training and experience required for
personnel to properly perform the duties of
specific job.
Technique: A category within an NDT
method; for example, ultrasonic,
ultrasonic thickness testing.
Training: an organized program
developed to impart the knowledge and
skills necessary for qualification.
Written Practice: a written procedure
developed by the PT. VERONIKA
PRIMA SANITA that details the
requirements for qualification and
certification of NDE Personnel.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 6 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


5

Tingkat Kualifikasi dan Tanggung 5


Jawab
Hak untuk menentukan tingkat penerimaan 5.1
dari material atau item yang diuji harus
dilaksanakan oleh Level II atau Level III
NDE

5.1

Levels
of
Qualification
and
Responsibility
Authorization for determining the
acceptability of materials or items tested
shall be performed by Level II or Level III

5.2

Trainee
5.2
Trainee
a. Seorang yang dalam proses awal di
a. An individual in the process of being
training, di qualifikasi, dan di sertifikasi.
initially trained, qualified, and certified.
b. Seorang trainee diijinkan bekerja dengan
b. An Trainee is allowed to work with or
atau membantu personnel yang telah
assist a certified individual but shall not
qualified
tetapi tidak diperkenankan
be allowed to independently conduct,
secara mandiri melakukan, interpret,
interpret, evaluate or report the result of
evaluasi atau membuat report dari NDT
any NDT Test.

5.3

NDE Level I
5.3
NDE Level I
a. Level I NDE harus dikualifikasi untuk bisa
a. An NDE Level I personnel shall be
dengan benar melakukan kalibrasi,
qualified to properly perform specific
examination khusus, dan evaluasi khusus
calibrations, specific test, and specific
sesuai dengan instruksi tertulis dan
evaluations
according
to
written
merecord hasilnya.
instructions and to record the results.
b. Dia harus menerima panduan atau
b. He shall receive the necessary guidance
supervisi dari personnel yang memiliki
or supervision from a certified NDE
sertifikat NDE Level II atau Level III.
Level II or III personnel.

5.4

NDE Level II
5.4
NDE Level II
Level NDE II harus dikualifikasi untuk
a. An NDE Level II personnel shall be
mensetup dan mengkalibrasi peralatan dan
qualified to set up and calibrate equipment
menginterpretasikan dan mengevaluasi
and to interpret and evaluate test result
hasil examination dengan mengacu Code,
with respect to applicable codes, standards
Standard dan Specifikasi yang berlaku.
and specifications.
Dia harus familiar dengan intrumentasi,
b. An NDE Level II shall be thoroughly
peralatan dan keterbatasan dari metodenya
familiar with the instruments, equipment
dan harus bertanggung jawab bila diminta
and limitations of the method and shall
membimbing saat on-the-job training
exercise assigned responsibility for on-thepersonnel yang sedang training dan
job training and guidance of trainees and
personnel NDE Level I.
NDE level I personnel.
Dia harus dapat menyiapkan instruksi
c. An NDE Level II shall be able to prepare
tertulis dan mengaturnya dan melaporkan
written instructions and to organize and
investigasi dari pelaksanaan uji tak
report
nondestructive
testing
merusak.
investigations.
Seorang personnel NDE Level II untuk
d. NDE Level II personnel for interpreter
Radiographic Interpreter harus qualified
shall be qualified to set up and calibrate
untuk mengeset dan mengkalibrasi
equipment and to interpret, evaluate the
peralatan dan menginterpret, mengevaluasi
quality of film radiographs and evaluate
qualitas film radiograpy dan evaluasi
indications or defects with respect to
indikasi atau cacat dengan pedoman Code
applicable
codes,
standards
and

a.

b.

c.

d.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 7 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


yang berlaku, Standard dan Spesifikasi.
e. Seorang personnel NDE Level II thickness
gauging
harus
familiar
dengan
intrumentasi, peralatan dan keterbatasan
dari metodenya dan harus qualified untuk
mengeset dan mengkalibrasi peralatan dan
menginterpret,
mengevaluasi
hasil
examination dengan pedoman Code yang
berlaku, Standard dan Spesifikasi.
5.5

specifications.
e. NDE Level II personnel for thickness
gauging shall be thoroughly familiar with
the instruments, equipment and limitations
of the method and shall be qualified to set
up and calibrate equipment and to
interpret, evaluate test results with respect
to applicable Codes, Standards and
Specifications.

NDE Level III


5.5
NDE Level III
a. Level III NDE harus bisa membuat,
a. An NDE Level III personnel shall be
mengqualifikasi,
dan
mengesahkan
capable of developing, qualifying, and
prosedur, menetapkan dan mengesahkan
approving procedures, establishing and
teknik pelaksanaan, menginterpretasikan
approving techniques, interpreting Codes,
Code, Standard, specifikasi dan dan
Standards, Specifications and Procedures;
prosedur; dan merencanakan metode NDE
and designating the particular NDE
yang penting, teknik dan prosedur yang
methods, technique and procedure to be
dipakai.
used.
b. Dia harus bertanggung jawab terhadap
b. NDE Level III personnel shall be
terselesaikannya operasi NDE sesuai
responsible for the NDE operations for
kualifikasi dan penugasannya dan harus
which qualified and assigned to which he
bisa interpretasi dan mengevaluasi hasil
is assigned and shall be capable of
sesuai dengan Code, Standard, dan
interpreting and evaluating results in terms
of existing Codes, Standards, and
Sesifikasi yang berlaku.
Specifications.
c. Dia harus memiliki latar belakang praktis
c. NDE Level III personnel shall have
tentang material, fabrikasi atau produk
sufficient practical background in
teknologi untuk menyediakan teknik yang
applicable materials, fabrication or product
sesuai dan membantu menetapkan kriteria
technology to establish techniques and to
assist in establishing acceptance criteria
penerimaan bila tidak tersedia.
where none are otherwise available.
d. Dia harus mengenal secara umum dengan
d. An NDE Level III personnel shall have
general familiarity with other commonly
metode-metode NDE lain yang digunakan.
used in NDE methods.
e. Dia, dengan metode yang disertifikasi,
e. An NDE Level III personnel, in the
harus mampu melatih dan menguji Level I
methods in which certified, shall be
NDE dan Level II NDE personnel untuk
capable of training and examining of NDE
Level I and Level II personnel for
sertifikasi pada method nya.
certification in those method.
f. Dia harus diberi wewenang untuk
f. NDE Level III personnel shall be
menyelenggarakan program pelatihan dan
authorized to administer the training and
certification program in accordance with
sertifikasi sesuai dengan prosedure ini.
this written practice.

6.

Pendidikan, Training dan Pengalaman

6.

6.1

Calon NDE sertifikasi harus mempunyai 6.1

Education, Training and Experience


Requirements
Candidates for certification in NDE shall

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 8 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


cukup
pendidikan,
training,
dan
have sufficient education, training, and
pengalaman untuk meyakinkan qualifikasi
experience to ensure qualification in those
pada NDE method. Dokumentasi sebelum
NDE methods. Documentation of prior
certifikasi dianggap sebagai bukti dari
certification is considered as evidence of
qualifikasi untuk level yang setara dari
qualification for comparable levels of
certifikasi.
certification.
Training dan / atau pengalaman yang 6.2
Documented training and / or esperience
6.2
didokumentasikan yang didapat pada
gained in positions and activities
posisi dan aktivitas yang setara dengan
comparable to those of levels I, II and / or
level I, II dan / atau III sebelum pembuatan
III prior to establishment of written
written practice bisa dianggap memenuhi
practice is considered in satisfying the
kriteria daro par. 6.3.
criteria of par. 6.3.
Calon NDE Level I dan II harus memenuhi 6.3
An NDE Level I and II Candidate shall
6.3
salah satu dari kriteria berikut:
satisfy one of the following criteria :
a. Personnel yang bersertifikasi NDE Level I
a. NDE Level I and II certified personnel
and II harus memiliki pendidikan,
shall satisfy the education, experience and
pengalaman dan pelatihan sesuai dengan
training requirements of Table 1 A and
Table 1 A dan Table 1 B
Table 1 B
b. Untuk kualifikasi langsung ke Level II,
b. For Level II direct qualification with no
jam pelatihan harus sedikitnya adalah
time at level I, the training hours shall
kombinasi jam yang dipersyaratkan untuk
consist of at least the combined required
Level I dan II pada metode yang berlaku,
hours for Level I and II in the applicable
terkecuali bila calon tersebut telah
method, except when the candidate has
terkualifikasi sebelumnya, atau memiliki
either been previously qualified to, or has
persamaan posisi sesuai dengan Level II,
held a position equivalent to that of a
dalam kasus ini persyaratan untuk
Level II, in which case, the requirement for
pelatihan dinyatakan telah terpenuhi.
training may be considered met.
An NDE Level III candidate shall satisfy
Calon NDE Level III harus mengikuti item 6.4
6.4
below item a and one of the following
a dan salah satu kriteria pendidikan
education and experience criteria ( b, c or d):
ataupun pengalaman (b, c atau d):
a. Memiliki jam training minimum jumlah
a. Have the training hours minimum the sum of
Level I and Level II in applicable method, as
dari level I dan level II sesuai metode,
stated in the Table 1 A.
seperti yang tercantum dalam Table 1 A.
b. Lulus dalam 4 tahun di perguruan tinggi
b. Have graduated of four (4) year college or
atau Universitas dengan tingkat sarjana
university with degree in engineering or
atau science , plus 1 tahun pengalaman
science , plus one (1) additional year of
2
melebihi syarat Level II NDE dalam
experience beyond the level
II
penugasan
yang minimum sebanding
requirements in NDE in an assignment at
dengan Level II NDE pada metode yang
least comparable to that of an NDE Level
digunakan, atau:
II in the applicable method(s), or :
c. Telah lulus, tidak kurang dari dua tahun
c. Have Completed with passing grades at
belajar di bidang engineering atau science
least two years of engineering or science
pada universitas yang terakreditasi,
study at an accredited university, college,
perguruan tinggi atau sekolah teknik
or technical school,
plus two (2)
ditambah 2 tahun pengalaman melebihi
additional years of experience beyond the
syarat2 Level II NDE dalam penugasan
level II requirements in NDE in an
yang minimum sebanding dengan Level II
assignment at least comparable to that of
an NDE Level II in the applicable
NDE pada metode yang digunakan, atau:
method(s), or :

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 9 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


d. Telah mempunyai pengalaman empat (4)
tahun melebihi syarat2 Level II NDE dalam
penugasan yang minimum sebanding
dengan Level II NDE pada metode yang
digunakan.
7
7.1

7.2

7.3

7.4

Program Pelatihan
Personel yang terpilih (trainee) harus
diberikan pelatihan yang terorganisir untuk
meyakinkan trainee benar-benar terbiasa
dengan prinsip dan praktek dari NDE
tertentu sehubungan dengan level dari
sertifikasi yang diinginkan dan proses yang
digunakan dan produk yang di uji.
Training harus termasuk teori, praktek,
program pengembangan dan perlakuan
pada pengujian tak merusak dan untuk
memenuhi pengalaman yang cukup untuk
memenuhi waktu yang disyaratkan pada
spesifik
teknik,
trainee
kemudian
dikembalikan ke NDE Level III. Pada saat
ini, trainee akan diberikan kelas pelatihan
untuk
metode
dimana
dia
akan
dikualifikasikan (Kelas pelatihan dapat
bersamaan dengan trainee mendapatkan
pengalamannya). Semua program training
harus di aprove oleh NDE Level III yang
bertanggung jawab.
Procedur diatas diikuti dalam pemilihan,
training dan kualifikasi personel yang tidak
memiliki pengalaman pengujian tak
merusak
sebelumnya.
Setelah
menunjukkan bukti training sebelumnya
dan/atau kualifikasi, NDE level III dapat
melakukan penilaian terhaddap program
training untuk latar belakang dan
pengalaman personel. Tipe pengujian
specific yang didefinisikan untuk setiap
NDE teknik akan diikuti dalam semua
kasus.
Jika PT. VERONIKA PRIMA SANITA
memakai jasa training service dari luar,
GENERAL
MANAGER
harus
bertanggung jawab untuk memastikan
bahwa training dari luar tersebut
memenuhi persyaratan dari written practice
ini.
Program pelatihan harus sesuai dengan
Written Practice ini dan Program Pelatihan

d. Have four (4) years of experience beyond


the level II requirements in NDE in an
assignment at least comparable to that of
an NDE Level II in the applicable
method(s).
7
7.1

7.2

7.3

7.4

Training Program
Personnel selected (trainee) are given
organized training for ensuring the trainee
is thoroughly familiar with the principles
and practices of specified NDE method
related to the level of certification desired
and applicable processes to be used and
product to be tested. The training shall
include
theory,
practical
training,
development
and
aptitude
in
nondestructive examination, and gain
experience for the appropriate time for
meeting the general time guide in the
specific technique; the trainees will be
referred back to the NDE Level III. At this
time, trainees will be given the classroom
training (classroom training may also be
given simultaneously as the trainee gains
practical experience) for the method in
which he will qualify.
All training programs shall be approved by
the responsible DNE Level III.
The above procedure will be followed in
selecting, training and qualifying personnel
with no previous experience in
nondestructive
examination.
Upon
presentation of proof of prior training and /
or qualification, the NDE Level III may
exercise judgement in tailoring the training
program to personnels background and
experience. The specific types of
qualification testing as defined for each
NDE technique will be followed in all
cases.
When PT. VERONIKA PRIMA SANITA
phurchase outside training services, the
GENERAL MANAGER shall be
responsible for ensuring that such services
meet the requirements of this written
practice
Training outline shall be as per this
Written Practice and NDE Training

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 10 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


NDE ANSI/ASNT CP-105 untuk sesuai
dengan masing masing metodenya
minimum harus digunakan sebagai acuan
8
8.1
8.1.1

8.1.2

8.1.3

8.1.4

Pengujian
Administrasi dan penilaian
NDE Level III harus bertanggung jawab
melakukan pengujian dan pembobotan
NDE Level I, II atau personnel Level III
lainnya.
Semua ujian tertulis harus closed book,
kecuali data yang diperlukan seperti grafik,
table, spesifikasi, procedure, Code boleh
disediakan selama dalam waktu ujian.

Program ANSI / ASNT CP - 105 for the


applicable method as a minimum shall be
used as technical source materials.
8
8.1
8.1.1

Examinations
Administration and Grading
The NDE Level III shall be responsible for
administration and grading the NDE Level
I, II or other Level III personnel.

8.1.2

All written examinations shall be closed


book, except the necessary data such as
graphs, tables, specifications, procedures,
Codes may be provided with during
examination.
The Level III shall be responsible to select
and approve all the examination questions

Level III harus bertanggung jawab untuk 8.1.3


memilih dan approve semua pertanyaan
ujian.
Untuk personnel Level I dan II, hasil grade 8.1.4
harus ditentukan dengan rata2 sederhana
dari hasil ujian general, spesifik, dan ujian
praktek, untuk personnel Level III , hasil
grade
harus ditentukan dengan rata2
sederhana dari hasil ujian basic, methode
dan ujian spesifik; seperti contoh dibawah
ini.
Susunan grade diatur sebagai berikut:
(Contoh Level II )
Examination
Actual Grade
General
70 %
Specific
84 %
Practical
90 %
Composite Grade = (70+84+90)/3 = 81.33
%

8.1.5

Hasil ujian kualifikasi harus lulus dengan 8.1.5


nilai rata rata gabungan minimum 80 %,
dengan nilai minimum 70 % untuk masingmasing pengujian.

8.1.6

Bila ujian dilaksanakan oleh badan atau 8.1.6


agensi diluar PT. VERONIKA PRIMA
SANITA dan hanya menyatakan lulus
atau tidak lulus, pada sertifikatnya, maka
PT. VERONIKA PRIMA SANITA bisa
menerima kelulusannya dengan nilai 80 %
untuk ujian tersebut.

For Level I and II personnel, a composite


grade shall be determined by simple
averaging of the results of the general,
specific and practical examinations, for
Level III personnel a composite grade shall
be determined by simple averaging of the
results of the basic, method and specific
examination; as example below.
The composite grade is determined as
follows : ( Example for Level II )
Examination
Actual Grade
General
70 %
Specific
84 %
Practical
90 %
Composite Grade = (70+84+90)/3 = 81.33
%

Examinations
administered
for
qualification shall result in a passing
composite grade of at least 80 %, with no
individual examination having a passing
grade less than 70 %.
When an examination is administrated and
graded for the by an outside agency and
issues grades of pass or fail only, on a
certified report, then PT. VERONIKA
PRIMA SANITA may accept the pass
grade as 80 %
for that particular
examination.

Procedure no.
Revision no.
Date
Page

PT. VERONIKA PRIMA SANITA

: VPS WP - 01
: 00
: 31 May, 2013
: 11 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


8.2
8.2.1

8.2.2

8.2.3

8.2.4

8.2.5

Pengujian penglihatan jarak dekat:


Penglihatan jarak dekat harus dilaksanakan
setiap tahun oleh Level III atau Dokter,
habis masa berlaku pada tanggal terakhir
pada bulan jatuh tempo nya.
Pengujian diperlukan untuk meyakinkan
penglihatan dekat baik normal ataupun
dengan kaca mata ninimum satu mata bisa
membaca tulisan huruf J-2 atau tipe dan
ukuran yang setara dengan jarak minimum
30 cm pada Tes Chart Standar Jaeger.
Sebagai tambahan NDE Level III harus
yakin bahwa kandidat tersebut memiliki
kemampuan untuk membedakan kontras
diantara warna2, menggunakan Ishiharas
Test Plates ( minimum 14 plates ).
Untuk personnel RT dan MT harus bisa
membedakan
bayangan
kelabu,
menggunakan copy atau computer dari
Shade Grey Test Plates dengan jarak 30 ~
40 cm. dengan pencahayaan kondisi kerja
normal pada computer. Syarat kelulusan,
minimum 20 pembacaan harus benar.

8.2
8.2.1

8.2.2

8.2.3

8.2.4

Hasil tes mata ini harus didokumentasikan 8.2.5


dalam Exhibit A atau form yang serupa.

Near Vision Acuity Examination :


Near Vision Acuity shall be administered
annually by Level III or Medical Doctor,
the examination expire on the last day of
month of expire.
An examination is required to assure
natural or corrected near vision in at least
one eye by reading J-2 letters or equivalent
type and size at a distance not less than 12
inches on a standard Jaeger test chart
In addition the NDE Level III shall satisfy
himself of the candidates ability to
distinguish and differentiating contrasts
among colours, using Ishiharas Test
Plates (minimum 14 plates).
For NDE personnel on RT and MT, they
shall be able to distinguish and
differentiating shades of grey, using a hard
copy or on computer screen of Shade Grey
Test Plates at a distance of 30 ~ 40 cm.
under normal desktop working light
condition. Passing grade, minimum 20
correct readings required.
The eye exam results shall be documented
in Exhibit A or similar form.

8.3
8.3.1

Detail dari Pengujian


8.3
Detail of Examinations
Ujian General Level I dan Level II 8.3.1
General Examination Level I and II
(tertulis):
(written ):
a. Ujian general harus melingkupi ujian dasar
a. The general examination shall cover the
yang berhubungan dengan metode yang
basic test principles relative to the
diaplikasikan.
applicable method.
b. Pertanyaan ujian harus meliputi metode
b. The examination questions shall covers
yang digunakan drajat yang diperlukan
the applicable methods to the degree
pada written practice dan NDE Training
required by this written practice and NDE
Program ANSI / ASNT CP 105 sebagai
Training Program ANSI / ASNT CP
panduan untuk metode RT, UT, MT dan
105 as a guide for RT, UT, MT and PT.
PT.
c. Minimum jumlah pertanyaan harus sesuai
dengan Table II
d. Certifikat ACCP Level II yang masih
berlaku memenuhi kriteria ujian General
dan Praktek pada setiap method yang
tersebut.
e. Certifikat ASNT Level II yang masih
berlaku memenuhi kriteria ujian General
pada setiap method yang tersebut.

c. The minimum number of questions shall


be as in Table II
d. A valid endorsement on an ACCP Level II
certificate fulfills the corresponding
criteria General examination and Practical
examination for each applicable method.
e. A valid ASNT NDE Level II certificate
fulfills the corresponding General
examination for each applicable method.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 12 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


8.3.2

Ujian Spesifik Examination Level I dan 8.3.2


Level II (Tertulis):
a. Pengujian spesifik harus melingkupi
a.
peralatan, prosedur operasi dan teknik uji.
Selain itu juga harus melingkupi
spesifikasi atau Code dan kriteria
penerimaan untuk prosedur NDE yang
dipakai.
b. Minimum jumlah pertanyaan harus sesuai
b.
dengan Table II
c. Ujian spesific bisa ditiadakan, jika calon
c.
mempunyai sertifikat yang masih berlaku
dari ACCP atau ASNT NDE Level II pada
method / sektor industri dan jika
pengalaman yang ada didokumentasikan.

8.3.3

Ujian Praktek Level I dan Level II

a. Ujian
praktek
harus
termasuk
pendemonstrasian kemampuan dalam
pelaksanaan metode uji tak merusak yang
digunakan dan evaluasi hasil yang didapat.
b. Satu atau lebih sampel cacat untuk ujian
RT, UT, MT dan PT harus di setujui oleh
NDE Level III. Hasil ujian praktek ini
harus didokumentasikan kedalam record
pengujian dengan harus dimasukkan
minimum 10 poin checklist tentang
pemahaman variabel dan persyaratan
persyaratan prosedur yang ada dalam PT.
VERONIKA PRIMA SANITA, harus
termasuk dalam ujian.
c. Untuk Radiographic Interpreter, minimum
10 (sepuluh) sample film harus digunakan
untuk ujian praktek dengan menjawab
minimum 10 checkpoints.

8.3.3

Specific Examination Level I and Level


II ( Written ) :
The specific examination shall cover the
equipment, operating procedures and test
techniques.
It
shall
also
cover
specifications or Codes and acceptance
criteria for the applicable NDE procedure.
The minimum number of questions shall
be as in Table II
The specific examination may be deleted,
if candidate has a valid ACCP or ASNT
NDE Level II certificate in the method /
industrial sector and if documented
experience exists to permit such.
Practical Examination Level I & Level
II
The practical examination shall comprise
demonstrated proficiency in performing
the applicable nondestructive examinations
and evaluations of the results obtained.
One or more flawed specimen for
examination of RT, UT, MT and PT shall
be approved by the NDE Level III. The
practical examination results shall be
documented on an examination record
with at least 10 check points requiring an
understanding of examination variables
and PT. VERONIKA PRIMA SANITAs
procedure requirements shall be included
for examination.
For Radiographic Interpreter, a minimum
10 (ten) sample of films shall be used for
practical examination with at least 10
checkpoints.

8.3.4 Pengujian untuk Level III


8.3.4
Examination for Level III
a. Ujian Basic (disyaratkan hanya sekali
a. Basic Examination ( required only once
when more than one method examination
ketika mengambil lebih dari satu metode):
is taken ) :
Limabelas (15) pertanyaan berkaitan
Fifteen (15) questions relating to
dengan pengertian dari dokumen SNT-TCunderstanding of the SNT-TC-1A
1A.
document.
Dua puluh (20) pertanyaan berkaitan
Twenty (20) questions relative to
dengan material, proses fabrikasi dan
applicable materials, fabrication and
teknologi produksi yang biasa dipakai.
product technology.
Dua puluh (20) pertanyaan yang dipilih
Twenty (20) questions selected from or

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 13 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


dari pertanyaan yang sama dengan
pertanyaan Level II pada metode NDE
tersebut.
b. Pengujian Metode (untuk setiap metode):
Tiga puluh (30) pertanyaan berkaitan
dengan pemahaman dasar, yang diambil
dari atau yang sama dengan pertanyaan
dari ASNT Level III untuk setiap
metodenya.
Lima belas (15) pertanyaan berkaitan
dengan aplikasinya dan penentuan teknik
dan prosedur yang diambil dari dan atau
yang sama dengan pertanyaan yang ada
dari ASNT Level III untuk setiap
metodenya.
Dua puluh (20) pertanyaan untuk
interpretasi Code, Standard dan spesifikasi
yang berkaitan terhadap metode tersebut.
Pemegang sertifikat yang masih berlaku
dari ASNT Level III or ACCP Professional
Level III telah memenuhi persyaratan yang
di par. 8.3.4 (a) dan 8.3.4 (b).
c. Ujian Spesifik (untuk setiap metode)
Dua puluh (20) pertanyaan tentang
spesifikasi, peralatan, teknik dan prosedure
tertulis yang diaplikasikan pada produk
dan metode yang dilaksanakan di PT.
VERONIKA PRIMA SANITA dan yang
ditulis dalam prosedur qualifikasi PT.
VERONIKA PRIMA SANITA.
Ujian specific dari method yang terkait
bisa diabaikan untuk
calon yang
pemegang sertifikat yang masih berlaku
dari ASNT Level III atau ACCP
Professional Level III dan jika di
dokumentasikan bukti dari pengalaman
nya, termasuk persiapan pembuatan
prosedur yang mengacu ke Codes,
Standards, atau Specification dan evaluasi
dari hasil ujian.
8.4

similar to the published Level II questions


of other appropriate NDE methods.
b. Method Examination ( each method ) :
Thirty (30) questions relating to
fundamentals and principles, which are
selected from or are similar to the
published ASNT Level III questions for
each method.
Fifteen (15) questions relating to the
application and the establishment of
techniques and procedures which are
selected from or are similar to the
published ASNT Level III questions for
each method.
Twenty (20) questions relating to the
interpretation of Codes, Standards and
Specifications related to the method.
A valid endorsement on an ASNT Level
III or ACCP Professional Level III
certificate fulfils the examnation criteria
described in par. 8.3.4 ( a ) and 8.3.4 (b)
for each applicable method.
c. Specific Examination ( for each method )
Twenty (20) questions relating to
specifications, equipment, techniques and
procedures applicable to PT. VERONIKA
PRIMA SANITAs product (s) and
methods
employed
and
to
the
administration of the PT. VERONIKA
PRIMA SANITAs written practice.
The specific examination in the applicable
method may be deleted for a candidate
who has a valid endorsement on an ASNT
Level III or ACCP Professional Level III
certificate in the method and if
documented evidence of experience exists,
including preparation of procedures to
Codes, Standards, or Specifications and
evaluation of the test results.

Ujian - ulang
8.4
Re-examination
a. Batasan dibawah ini harus dipakai syarat
a. The following limitations shall be applied
ujian ulang dari personnel dalam
on re-examination of personnel for
qualification
in
non-destructive
kualifikasi uji nondestructive:
examination :
b. Personnel gagal memenuhi grade yang
b. Personnel failing to attain the required

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 14 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


dibutuhkan harus menunggu paling sedikit
30 hari atau menerima tambahan training
yang cocok ditentukan oleh Level III
penguji sebelum dilakukan pengujian
kembali.

grade must wait at least 30 days or receive


suitable additional training as discretion by
the Level III examiner prior to being reexamined.

9
9.1

Sertifikasi
9
Setelah berhasil melewati ujian kualifikasi 9.1
, personnel tersebut harus disertifikasi
sesuai dengan metode dan level untuk
kualifikasinya.
Sertifikat qualifikasi untuk RT, UT, PT,
MT harus di tanda tangani
oleh
GENERAL MANAGER dan diverifikasi
oleh NDE Level III metode yang terkait.
Sertifikasi (Exhibit B atau form serupa)
harus
disimpan
kedalam
file
nondestructive

9.2

Personnel NDE Level I or II for PT, MT, 9.2


UT dan RT yang bergabung keperusahaan
yang telah dikualifikasi oleh Institusi
diluar dan dapat menunjukkan sertifikat
authentic telah memenuhi persyaratan
qualifikasi dari PT. VERONIKA PRIMA
SANITA
written practice dan bisa
disertifikasi setelah lulus ujian general,
specific dan praktek yang ditentukan oleh
NDE Level III.

9.3

NDE Level III akan menyimpan semua 9.3


record sertifikasi. Bila NDE level III dari
subkontrak,
GENERAL MANAGER
harus menyimpan record sertifikasi.
Record personnel yang qualified akan
termasuk tersebut dibawah ini:

Certification
Upon
successful
completion
of
qualification examination, the personnel
shall be certified in the method and to the
level for which he is qualified.
The qualification certificate for RT, UT,
PT, MT shall be verified by the NDE
Level III in applicable method and shall be
certified by the GENERAL MANAGER.
The certification record (Exhibit B or
similar form) shall be maintained in the
nondestructive examination personnel
records file.
NDE Personnel Level I or II for PT, MT,
UT & RT joining the company who have
been qualified by Outside Agencies or
Government qualification (i.e. BATAN for
RT) and can provide authentic certificates
or License fulfils the qualification
requirements of PT. VERONIKA PRIMA
SANITAs written practice and shall be
certified after have passed general, specific
and practical examination at the discretion
of the NDE level III.
The NDE Level III shall maintain the
certification records. If NDE Level III
Services
are
subcontracted,
the
GENERAL MANAGER shall maintain
records of certification. Personnel records
of certified personnel will include the
followings :
1. Name of certified personnel.
2. Level of certification and test
method.
3. Education
background
and
experience of certified personnel.
4. Statement indicating satisfactory
completion of training.
5. Result of current eye examination
6. Current examination copy(ies) or
evidence of successful completion of
examinations.
7. Other
suitable
evidences
of

1.
2.
3.
4.
5.
6.

Nama dari personnel tersebut.


Level dari sertifikasi dan metode
examinationnya
Latar belakang pendidikan dan
pengalaman kerjanya.
Pernyataan memuaskan penyelesaian
complete training.
Hasil dari examination mata yang
berlaku
Copy dari ujian atau bukti kesuksesan
komplet ujian

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 15 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


7.

Bukti lain
untuk kecukupan
qualifikasi bila kualifikasi digunakan
sebagai pengganti ujian specific sesuai
par. 8.3.5 (b).
8. Bobot persen rata rata atau bukti
bobot yang sesuai.
9. Tanda tangan Level III yang
memverifikasi qualifikasi dari calon
untuk sertifikasi. Untuk sertifikasi
level III, harus diverifikasi
oleh
GENERAL MANAGER.
10. Tanggal
sertifikasi
dan/atau
resertifikasi dan penunjukkan untuk
NDE.
11. Tanggal berlakunya sertifikat.
12. Tanda tangan employer berwenang
yang mensertifikasi sertifikasi (
GENERAL
MANAGER
PT.
VERONIKA PRIMA SANITA)
Interval sertifikasi tidak boleh melebihi
9.4
ketentuan ini :
Level I , II dan III = 5 tahun
Habis masa berlaku sertifikat pada tanggal
terakhir pada bulan jatuh tempo nya.

9.4

10

satisfactory qualifications when such


qualifications are used in lieu of the
specific examination prescribed in
par. 8.3.5 ( b ).
8. Composite grade(s) or suitable
evidence of grade.
9. Signature of Level III that verified
qualifications of candidate for
certification.
For
level
III
certification, it shall be verified by
GENERAL MANAGER
10. Date of certification and / or recertification and date of assignments
to NDT.
11. Certification expiration date.
12. Signature of PT. VERONIKA
PRIMA
SANITAs
certifying
authority (GENERAL MANAGER )
Certification shall not exceed the following
intervals :
Level I , II and III = 5 years
The certifications expire on the last day of
the month of expire.

Technical Performance Evaluation


10
Technical Performance Evaluation
a. Personnel NDE bisa diuji setiap saat dan
a. NDT personnel may be re-examined any
sertifikat yang dimiliki bisa diperpanjang
time and have their certificates extended or
atau dicabut sesuai kebijaksanaan level III
revoked as discretion by Level III
b. Technical performance harus dilaksanakan
b. Technical performance evaluation shall be
2
conducted annually using practical method
setiap tahun menggunakan pertanyaan
questions (with at least 10 check points)
(minimum 10 check point) yang
related to the applicable NDE method by the
berhubungan NDE methodenya oleh Level
Level III. The evaluation and documentation
III. Evaluasi dan dokumentasi mengikuti
shall follow the format and guidelines
format dan petunjuk sesuai paragraph
described in paragraph 8.3.3.
8.3.3.
c. Sebagai ganti dari Technical performance
c. In lieu of the above Technical performance
evaluation, ujian harus dilaksanakan pada
evaluation, the examinations shall be
conducted in general, specific and
general, specific dan practical.
practical.

11
11.2

Interupsi Pelaksanaan
11
Demonstrasi yang tidak berlanjut terhadap 11.1
service, pengetahuan atau performance
keterlambatan
dalam
sertifikat
perpanjangan waktu kualifikasi (Table 1 A
dan 1 B). Dalam keadaan yang serupa atau
sama diatas terjadi, NDE level III akan

Interrupted Service
Lack of continued demonstration of
satisfactory service, knowledge or
performance and delays in certification due
to extended experience qualifying time
(Table IA and 1B). In the event that
circumstances similar to or the same as

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 16 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

11.2

mereview secara detail keadaan secara


specific dan menentukan kursus yang
diperlukan atau mencabut sertifikat, ujian
ulang atau melakukan evaluasi lanjuta
terhadap performance praktek personel.

above arise, the NDE level III will review


in detail the specific circumstances and
determine the necessary course or action to
revoke
certification,
required
reexamination
or
conduct
extended
evaluation of the personnels practical
performance.

Tidak dalam kondisi yang sesuai 8.4 (re- 11.2


examination), periode dimana terdapat
interupsi pelaksanaan yang lebih dari 6
bulan harus diadakan evaluasi ulang
terhadap kompetensi seseorang oleh NDE
Level III.

Not withstanding the provisions of 8.4 (Reexamination), any period of interrupted


service more than 6 months shall require re
evaluation of the personnels competence by
the NDE Level III.

12

Re-sertifikasi
12
Re-certification
Semua level dari personnel NDE harus
All levels of NDE personnel shall be redisertifikasi ulang sesuai dengan salah satu
certified in accordance with one of the
dari kriteria-kriteria berikut ini:
following criteria :
a. Adanya bukti kontinyuitas evaluasi tehnik
a. Evidence of continuing satisfactory technical
performance of NDE personnel level I and II
kinerja yang memuaskan untuk level I dan
as described in paragraph 10. Unsatisfactory
II sesuai paragraph 10. Hasil yang tidak
results of technical performance, the NDE
memuaskan dari technical performance,
personnel shall be reviewed for further
personel NDE harus direview untuk
evaluation by the Level III and the
evaluasi lebih lanjut oleh level III dan
GENERAL MANAGER. The corrective
GENERAL
MANAGER.
Tindakan
action may be additional test, re-examination
koreksi bisa dengan ujian tambahan, ujian
or revoke of the NDE certificate.
ulang atau pencabutan sertikat NDE.
b. Bukti
kontinyuitas
kinerja
yang
b. Evidence of continued satisfactory
memuaskan dari NDE Level III seuai
performance of the NDE Level III duties,
tugasnya, seperti yang ditentukan oleh
as determined by the
GENERAL
GENERAL
MANAGER,
boleh
MANAGER, may be used as the basis for
digunakan sebagai dasar sertifikasi ulang
re-certification of the NDE Level III.
NDE Level III.

13

Pemutusan
13
Personnel yang disertifikasi dengan 13.1
prosedur ini, sertifikatnya tidak berlaku
lagi dengan berakhirnya hubungan kerja
mereka di PT. VERONIKA PRIMA
SANITA.
Personnel yang sertifikasinya berakhir, 13.2
boleh disertifikasi ulang sebagai level
NDE seperti yang lalu oleh PT.
VERONIKA
PRIMA
SANITA
berdasarkan pada ujian, sesuai paragraf 8,
asalkan semua persyaratan seperti berikut
bisa terpenuhi:
a. Personnel telah menyetujui sebelum
a.

Termination
Personnel certified under this procedure
shall have their certification revoked upon
termination of employment with PT.
VERONIKA PRIMA SANITA.
Personnel whose certification has been
terminated may be re-certified to the
former NDE level by PT. VERONIKA
PRIMA SANITA based on examination as
described in par. 8, provided all of the
following conditions are met :
The

personnel

has

proof

of

prior

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 17 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


adanya sertifikasi
b. Terus bekerja dalam kapasitasnya sesuai
sertifikatnya dalam waktu enam (6) bulan
setelah masa berhentinya.
c. Personnel disertifikasi ulang dalam waktu
enam (6) bulan setelah masa berhentinya
d. Sebelum pengujian untuk sertifikasi,
personnel
yang
tidak
memenuhi
persyaratan
tersebut
diatas
harus
mendapatkan tambahan pelatihan yang
cukup dari NDE Level III.
14

Pembaruan
14
Personnel yang sertifikasinya telah habis,
bisa diperbarui sesuai NDE level awalnya,
tanpa adanya ujian baru, asalkan semua
persyaratan berikut terpenuhi:
a. PT. VERONIKA PRIMA SANITA telah
menyimpan record sertifikat personnel
yang dibutuhkan di paragraph 9.3
b. Sertifikat dari personnel belum habis masa
berlakunya.
c. Pembaruan sertifikat dalam kurun waktu
enam (6) bulan sebelum habis masa
berlakunya.

certification
b. The personnel was working in the capacity
to which certified within six (6) months
of termination.
c. The personnel is being re-certified within
six ( 6 ) months of termination
d. Prior to being examined for certification,
personnel do not meet the above
requirements shall receive additional training
at the discretion of the NDE level III.

Reinstatement
Personnel whose certification has been
terminated may be reinstated to the former
NDE level, without new examination,
provided all the following conditions are
met:
a. PT. VERONIKA PRIMA SANITA has
maintained the personnel certification
records as required in par. 9.3
b. Personnel certification did not expire
during termination.
c. Personnel are being reinstated within six
(6) months of termination.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 18 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

Table I. A
Initial Training and Experience Level
Experience
Examination
Method

NDT
Level

Liquid
Penetrant

Magnetic
Particle
Radiological

Ultrasonics

Technique

Training
Hours

Minimum Hours
in Method

Total Hours
in NDT

70

130

II

140

270

12

70

130

II

210

400

40

210

400

II

40

630

1200

40

210

400

II

40

630

1200

Radiographic

II

Time of Flight
Diffraction

40

160

NA

II

Phased Array

80

160

NA

Remarks

Starting Point,
UT - II
Starting Point,
UT - II

Note:
1. For Level II certification, the experience shall consist of time at Level I or equivalent. If person is being qualified
directly to Level II with no time at Level I, the required experience shall consist of the sum of the times required
for Level I and Level II and the required training shall consist of the sum of the hours required for Level I and
Level II.
2. For Level III certification, the required experience shall consist of the sum of time required for Level I and Level
II, plus additional time in par. 6.2 as applicable. The required formal training shall consist of the Level I and
Level II training plus additional formal training of product knowledge training, auditor training or other suitable
training at the discretion by GENERAL MANAGER
3. While fulfiling total NDT experience requirement, experience may be gained in more than ( 1 ) method,
however, the minimum hours shall be met for each method.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 19 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

Table I. B
Initial Training and Experience Level for
NDT Level II Limited Certification
Examination
Method

Radiographic

Ultrasonic

Limited Certification
Film Interpretation
Film Interpretation
Digital Thickness
Measurement ( numeric
output only )
A-Scan Thickness
Measuremen

Technicians
Starting Point
NonRadiographer
Level I

Formal
Training

Minimum Required Work


Experience in Method
(hours)

40

2201

24

2201

Trainee

40

Trainee

24

175

1 Require practical review of 1000 radiographs.

Table II
Minimum Number of Examination Questions
Method
Magnetic Particle Testing
Liquid Penetrant Testing
Radiography Testing
Radiographic Interpreter Non
Radiographer
Radiographic Interpreter
Radiographer ( Certified RT - I )
Ultrasonic Testing :
- Time of Flight Diffraction
- Phased Array
- Digital Thickness Measurement
( numeric output only )
- A-Scan Thickness Measurement

General

Specific
Level I
Level II
20
20
20
20
20
20

Level I
40
40
40

Level II
40
40
40

NA

40

NA

20

NA

20

NA

15

40
NA
NA

40
NA
NA

20
NA
NA

20
30
30

NA

20

NA

10

NA

30

NA

15

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 20 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

EXHIBIT A
EYE EXAMINATION RECORD

Employee Name

Company

Near Vision

Natural

Corrected

Left

Right

Both

Left

Right

Both

______

_______

______

_______

______

_______

Jaeger, with min.


distance 304 mm

Results of
Near Vision Acuity

Colour Contrast Differentiation


(Colour Blindness Ishiharas Test )

Shade of Gray

1, 2, 3, 4, 4, 5, 6, 8, 9, 10, 11, 12, 13, 14

; Read ____ of 25 plates

Examination administered by

Signature

Title

Exam. D a t e

Re-exam Date

( Shade of Gray Chart )

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 21 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

E XHIBI T B
NDE PERSONNEL CERTIFICATION RECORD

Name

Education

Experiences

Training

ID No. :

Training courses listed bellows were satisfactorily completed in accordance with VERONIKA
PRIMA SANITAs Written Practice

Training Course

Method &
Level

General

Date of Assignment
Technique
Sector
Material

Examination Results
Specific
Practical

Dates

Composite
Grade

Instructor

Training
Hours

Certification
Date

Expiration Date

:
:
:
:

Certification based on satisfactorily passing examinations.


This to certify that the above training, experiences, qualification and certification meets the requirements of Greatways engineering
services Written Practice for Qualification and Certification of NDE Personnel Procedure No : VPS-WP-01 , Revision : 00
Batam,
Verified by,

NDE Level III


Note :
PT.
MT.
RT.
UT.

: Liquid Penetrant Testing


: Magnetic Particle Testing
: Radiographic Testing
: Ultrasonic Testing

Certified by,

GENERAL
MANAGER

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 22 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

EXHIBIT C

TRAINING COURSE SYLLABUS


APPENDIX I

C1.

TRAINING
HOURS
4

LIQUID PENETRANT TESTING : LEVEL I

Introduction : History and Purpose


Liquid Penetrant Processing
Various Penetrant Testing Methods
Liquid Penetrant Testing Equipment and Testing Aids
TOTAL HOURS

C2.

TRAINING
HOURS
8

LIQUID PENETRANT TESTING : LEVEL II

Review of Basic Principles and Method


Selection of Appropriate Penetrant Testing Method
Inspection and Evaluation of Indications
Inspection Procedure and Standards
Basic Methods of Instruction
TOTAL HOURS

8
TRAINING
HOURS

C3.

MACNETIC PARTICLE TESTING : LEVEL I

Theory and Principles of Magnet and Magnetic Fields


Characteristics of Magnetic Fields
Effects of Discontinuities of Material
Magnetization by Means of Electric Current
Selecting the Proper Method of Magnetization
Inspection Medium / Materials
Principles of Demagnetization
Magnetic Particle Testing Equipment
Types of Discontinuities Detected by Magnetic Particle Testing
Magnetic Particle Test Indications and Interpretations
TOTAL HOURS

C4.

MACNETIC PARTICLE TESTING : LEVEL II


Theory and Principles :
Flux Strength and Patterns
Material Hardness and Heat Effects
Flux Field

:
Direct Current
Rectified Direct Current
Alternating Current
Permanent Magnets

12

12
TRAINING
HOURS
8

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 23 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

Effects of Discontinuities of Material


Magnetization by Means of Electric Current
Selecting the Proper Method of Magnetization
Demagnetization Procedures
Types of Equipment and Testing Medium
Types of Discontinuities
Evaluation Techniques and Standards
Equipment Maintenance, Check and Process
TOTAL HOURS

C5.
1.

2.

TRAINING
HOURS

RADIOGRAPHIC TESTING : LEVEL I


Radiographic Equipment Operating and Instruction Course

Personnel Monitoring Devices Usage


Survey Instrument Usage
Leak Testing of Sealed Radioactive Sources
Radiation Survey Report
Radiographic Work Practices
Exposure Devices
Emergency Procedure
Storage and Shipment of Exposure Devices and Sources
National Regulation

Basic Radiographic Physic Course

20

Introduction : History of Radioactive Materials


Industrial Radiography
Radiation Protection
Basic Mathematics
Fundamental of Matter
Radioactive Materials
Types of Radiation
Interaction of Radiation with Matter
Biological Effects of Radiation
Exposure Devices and Radiation Sources
3.

Radiographic Technique Course

15

Introduction : Radiographic Processes


Electromagnetic Spectrum
Types of Radiation Sources
Basic Principles of Radiography
Film and Radiographs
Radiographic Image Quality
Film Handling, Loading and Processing
Radiographic Exposure Techniques
Fluoroscopic Technique
TOTAL HOURS

40

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 24 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

C6.

RADIOGRAPHIC TESTING : LEVEL II

1.

Film quality and Manufacturing Processes Course

2.

20

Review of Basic Radiographic Principles


Darkroom Facilities, Technique and Processing
Indication, Discontinuities and Defects
Manufacturing Processes and Associated Discontinuities
Radiological Safety Principles Review

Radiographic Evaluation and Interpretation Course

20

Radiographic Viewing
Application Techniques
Evaluation of Castings
Evaluation of Weldments
Standards, Codes and Procedures for Radiography
TOTAL HOURS

C7.

ULTRASONIC TESTING : LEVEL I

1.

Basic Ultrasonic Course

2.

TRAINING
HOURS
20

Introduction
Basic Principles of Acoustics
Equipment
Basic Testing Methods
20

Ultrasonic Technique Course

Testing Methods
Calibration ( Electronic and Functional )
Straight Beam Examination to Specific Procedures
Angle Beam Examination to Specific Procedures
TOTAL HOURS

C8.

40

TRAINING
HOURS
40

ULTRASONIC TESTING : LEVEL II


Ultrasonic Evaluation Course

40

Review of Ultrasonic Techniques Course


Evaluation of Base Material Product Forms
Evaluation of Weldments
Evaluation of Bonded Structure
Discontinuity Detection
Evaluation
TOTAL HOURS

40

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 25 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

C9.

PHASED ARRAY ( PA )ULTRASONIC TESTING : LEVEL II


Introduction
Basic Principles o PA
Equipment ( Computer based systems, focal law, generation, probes,
wedges, scanners)
Testing Technique
Calibration
Data Collection
Procedures
Data Presentation
Data Evaluation
Reporting
TOTAL HOURS

C10.

TIME OF FILGHT DIFFRACTION ( TOFD ) : LEVEL II


Introduction
Basic Principles of TOFD
Equipment ( Computer based systems, beam profile, probes, wedges,
scanner )
Testing Technique
Calibration
Data Collection
Procedures ( specific applications )
Data Presentation
Data Evaluation
Parabolic cursor(s)
Reporting
TOTAL HOURS

TRAINING
HOURS
80

80

TRAINING
HOURS
40

40

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 26 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

APPENDIX II
GRADING PRACTICAL EXAMINATION
RADIOGRAPHIC TESTING
1. All individual shall demonstrate his proficiency in producing radiographs in at least two different
techniques. At least one radiograph to be produced for each technique inclusive of processing.
2. This examination will be graded for the following items.

Exposure time calculation.


Quality of radiographs.
Compliance with testing procedure / technique sheet provided.
Knowledge on equipment and materials used where the individual is requested to fill in a format on
equipment / material used and reporting.

3. All radiographs will be interpreted and sensitivity calculated by the individual being qualified. The
individuals comment on the qualities of weldment and radiographs shall be considered. No major
indications shall be missed. ( For Level II only )
4. At least ten check points prepared and approved by the NDT Level III shall be used as a basis in grading
of practical examination.
5. With adequate experience and written proof of certification by an audited outside agency or national
certifying body, i.e. Indonesia Atomic Energy commission ( BATAN ), the NDT Level III may waive
examinations for radiographic testing personnel. This clause is applicable only for radiographic inspection
personnel operating radiation sources with a detailed operating procedure under the local statutory
requirements inside Indonesia

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 27 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

APPENDIX III
GRADING PRACTICAL EXAMINATION
ULTRASONIC TESTING
1.

Categories of Qualification: Ultrasonic testing certification shall be categorized according to weld joint
configuration. If none is specified in the certificate, it shall mean the individual is qualified for all
configurations or materials.
CATEGORY
Constant Configuration

NO. OF SPECIMEN
1

Variable Configuration
1
Test specimens may or may not contain material discontinuities.

DESCRIPTION
One (1) in-line butt joint or one (1)
Tee/nozzle-type joint, full or partial
penetration joint.
One (1) node-type ( TKY ) joint

2.

The individual being examined shall submit a written report in a standard format, of ultrasonic test with a
sketch containing the nature, size (length and width), location along the weld and position within the weld
cross section, of all reportable indications.

3.

The individuals performance rating shall be calculated in accordance with the following formula :

P = Percentage of reflector correctly detected and


sized.
R = Passing grade 70%overall rating including
penalty for false alarms.
La = Passing grade 50% the length of actual reflector
R = (Lc / Li) x (1 (Lf / Li) x 100
contained in the specimen
Lc = The sum of indicated length of reflectors that
have been correctly sized and located.( Credit is given
for the lesser of the reported length or actual length of
the reflector)
Li = The total length of reflectors reported by the
candidate, right or wrong.
Lf = The total length of reported indications where no
reflectors exist
4. Additionally, the individual shall be subjected to oral test where knowledge on equipment check and
calibration, flaw sizing technique, codes/standard, practical problem likely to be encountered, limitations of
the test system, will be assessed.
P = (Lc / La) x 100

Where :

5. At least ten check points prepared and approved by the NDT Level III shall be used as basis in grading of
practical examination.
6. Practical examination may be carried out on production welds counter checked by the NDT Level III or his
designee.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 28 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL

APPENDIX IV
GRADING OF PRACTICAL EXAMINATION
MAGNETIC PARTICAL OR LIQUID PENETRANT TESTING
1. At least one ( 1 ) specimen shall be used for examination.
2. All indications, relevant or non-relevant shall be reported, on a standards report format including comments
on indications found.
3. Oral test shall be conducted to assess the individuals knowledge on the limitation of the test system,
techniques and procedures used, code / standard, and equipment sensitivity calibration.
4. In cases where test specimens containing known discontinuities are not available, specimens without
discontinuity may be used where the test technique will be assessed.
5. At least ten check point prepared and approved by the NDT Level III shall be used as a basis in grading of
practical examination.
6. Practical examination may be carried out on production welds witnessed by the NDT Level III or his
designed examiner.

PT. VERONIKA PRIMA SANITA

Procedure no.
Revision no.
Date
Page

: VPS WP - 01
: 00
: 31 May, 2013
: 29 of 29

WRITTEN PRACTICE FOR QUALIFICATION & CERTIFICATION OF NDE PERSONNEL


APPENDIX V

Eye Examination: Shades of Gray


Instructions: Use as a hardcopy or on the Computer screen at a distance of 30-50 cm under
normal desktop working light conditions.
Passing grade: min.20 correct readings required.

33

22

11

18

12

67

39

26

84

34

101

68

45

73

91

44

88

You might also like