Project Information
Current input file
Project title
Calculation type
Fracture
Assessment level
Level 2
Comments
Operation ECA - DJ
Geometry
Geometry type
Flaw type
Surface
24
mm
Width/length, W
1080
mm
Radius, rm
172
mm
Flaw Dimensions
Flaw height, a
mm
Flaw length, 2c
100
mm
Parametric angle
Max
Primary Stresses
Membrane stress, Pm
10
MPa
Bending stress, Pb
MPa
Secondary Stresses
Type
MPa
MPa
MPa
MPa
500
MPa
Young's modulus
2.5E+05
MPa
Poisson's ratio
0.3
1.18
Tensile Properties
Yield strength (Assess. temp) y
MPa
Material Specific
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk
28/03/2014
Page 2 of 6
Engineering Stress
Strain %
500
0.2
500
1.2
501
2.3
505
2.35
510
2.5
520
2.8
533
3.1
550
3.3
570
3.7
585
4.2
590
4.8
600
5.2
610
6.8
620
8.3
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk
28/03/2014
Page 3 of 6
Toughness (J)
Toughness
300
kJ/m2
Minimum
10
Maximum
600
Points
60
Sensitivity results
Primary membrane stress (Pm)
Results
10
Acceptable
20
Acceptable
30
Acceptable
40
Acceptable
50
Acceptable
60
Acceptable
70
Acceptable
Errors
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk
28/03/2014
Page 4 of 6
Acceptable
90
Acceptable
100
Acceptable
110
Acceptable
120
Acceptable
130
Acceptable
140
Acceptable
150
Acceptable
160
Acceptable
170
Acceptable
180
Acceptable
190
Acceptable
200
Acceptable
210
Acceptable
220
Acceptable
230
Acceptable
240
Acceptable
250
Acceptable
260
Acceptable
270
Acceptable
280
Acceptable
290
Acceptable
300
Acceptable
310
Acceptable
320
Acceptable
330
Acceptable
340
Acceptable
350
Acceptable
360
Acceptable
370
Acceptable
380
Acceptable
390
Acceptable
400
Acceptable
410
Acceptable
420
Acceptable
430
Acceptable
440
Acceptable
450
Acceptable
460
Acceptable
470
Acceptable
480
Acceptable
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk
28/03/2014
Page 5 of 6
Acceptable
500
Acceptable
510
Acceptable
520
Acceptable
530
Acceptable
540
Acceptable
550
Acceptable
560
Acceptable
570
Unacceptable
580
Unacceptable
590
Unacceptable
600
Unacceptable
1
0.9
0.8
0.7
Kr
0.6
0.5
0.4
0.3
0.2
0.1
0
0
0.2
0.4
0.6
0.8
1.2
1.4
Lr
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk
28/03/2014
Page 6 of 6
Stress MPa
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0
4
5
Strain %
TWI Software, Granta Park, Great Abington, Cambridge, CB21 6AL, UK. Tel : +44(0)1223 899000, Fax : +44(0)1223 892588, Email : crackwise@twi.co.uk