Note: The speed limits in Group 20 Limits are linked to the setting of
99.08 MOTOR NOM SPEED. If value of Parameter 99.08 MOTOR
NOM SPEED is changed, the speed limit settings change automatically
as well.
99.09 MOTOR NOM
POWER
99.10 MOTOR ID RUN
This parameter matches the ACS 600 to the rated power of the motor,
adjustable between 0 kW and 9000 kW.
This parameter is used to initiate the Motor Identification Run. During
the run, the ACS 600 will identify the characteristics of the motor for
optimum motor control. The ID Run takes about one minute.
The ID run cannot be performed if the scalar control mode is selected
(Parameter 99.04 MOTOR CTRL MODE is set to SCALAR).
NO
The Motor ID Run is not performed. This can be selected in most
applications. The motor model is calculated at first start by magnetising
the motor for 20 to 60 s at zero speed.
Note: The ID Run (Standard or Reduced) should be selected if:
operation point is near zero speed
operation at torque range above the motor nominal torque within
wide speed range and without any pulse encoder (i.e. without any
measured speed feedback) is required.
STANDARD
Performing the Standard Motor ID Run guarantees that the best
possible control accuracy is achieved. The motor must be de-coupled
from the driven equipment before performing the Standard Motor ID
Run.
REDUCED
The Reduced Motor ID Run should be selected instead of the Standard
ID Run:
if mechanical losses are higher than 20 % (i.e. the motor cannot be
de-coupled from the driven equipment)
if flux reduction is not allowed while the motor is running (i.e. in case
of a braking motor in which the brake switches on if the flux is
reduced below a certain level).
3-4
Firmware Manual
Note: Check the rotation direction of the motor before starting the
Motor ID Run. During the run the motor will rotate in the forward
direction.
ID Run Procedure
REM
1 L ->1242.0 rpm
99 START-UP DATA
10 MOTOR ID RUN
[STANDARD]
1 L ->1242.0 rpm
ACS 600 55 kW
**WARNING**
ID RUN SEL
Firmware Manual
3-5
3-6
Firmware Manual