You are on page 1of 38

Parameter Configuration

Nokia Siemens Networks

RN31632EN40GLA0

Parameter Configuration:
Module Objectives
At the end of the module you will be able to:
Explain the NSN RNC parameter database structure
Name and describe the different Managed Object types
Explain the usage of parameter templates
Explain how parameters are updated and maintained in NSN RAN

Nokia Siemens Networks

RN31632EN40GLA0

Logical Structure of the RNC Database Objects


VCEL

COSITE

VBTS

RNC
COSRNC

Various feature objects


IUx

IPQM

RNx

WRAB
HOPG

COCO

WBTS

IPNB

HOPI

TQM

HOPS

FMCS

ADJD

FMCI

ADJS

WCEL

ADJI

FMCG

ADJG/L
3

WAC

Nokia Siemens Networks

RN31632EN40GLA0

RNC object structure with IUx, RNx, features objects


WSG

WANE

WLCSE

CMOB

WSMLC

CBCI

PFL

RNC

RNAC

RNPS

RNFC

RNRLC

RNHSPA

RNTRM

RNMOBI

Nokia Siemens Networks

IUCS

IUPS

IUCSIP

IUPSIP

RN31632EN40GLA0

IUR

WANE = WCDMA Authorized Network


WSG = WCDMA subscriber group
CMOB = Congestion Management OBject

WLCSE = WCDMA Location service entity


WSMLC = WCDMA Serving Mobile Location Center

New Objects / Managed Object types

CBCI cell broadcast center information


PFL preferred frequency layer for different UE capability
WAC UL load control AC and several state transition control parameters
VBTS Virtual BTS
VCEL Virtual cell
COSITE/COSRNC co-siting objects

RNC = Radio Network Controller


WBTS = WCDMA Base Station
WCEL = WCDMA Cell
ADJ = Adjacency for WCDMA cell
ADJS = intra-frequency adjacency
ADJI = inter-frequency adjacency
ADJG = inter-system adjacency GSM
ADJL = inter-system adjacency LTE
ADJD = detected adjacency
HOP = Handover Path
HOPS, HOPI, HOPG
FMC = Frequency Measurement Control
FMCS, FMCI, FMCG

Nokia Siemens Networks

RN31632EN40GLA0

COCO = Radio Network Connection Configuration


CMOB = Congestion Management OBject
WANE = WCDMA Authorized Network
WSG = WCDMA subscriber group
WLCSE = WCDMA Location service entity
WSMLC = WCDMA Serving Mobile Location Center
IPNB = IP NodeB
IPQM = IP transmission QoS
TQM = Transmission Quality Management
WRAB = WCEL RAB parameters
IUPS/IUCS = Iu-CS / Iu-PS interfaces
WAC WCEL Admission Control
PFL = Preferred Frequency Layer

RNC Object
The logical object of the Radio Network Controller
It can have up to 2800 WBTS objects (requires RNC 2600)
In the RNC object the following interfaces are defined: Iu-PS, Iu-CS & Iur

The logical object are hierarchically related to each other, therefore it is not possible to
create any other object before RNC creation.
Added
already
in
RN4.0

VCEL

VBTS

RNC
IUx

RNC, RNAC, RNFC,


RNHSPA, RNMOBI,
RNPS, RNRLC, RNTRM

RNx

WRAB
HOPG

COCO
from RU30 on, the RNC
object is split into
several new Object
types, e.g.:

New in
RN7.0

COSRNC

Various feature objects

IPQM

Remark:

COSITE

WBTS

IPNB

HOPI

TQM

HOPS

FMCS

ADJD

FMCI

WCEL

ADJS
ADJI

FMCG

ADJG/L
WAC
6

Nokia Siemens Networks

RN31632EN40GLA0

New in
RN7.0

RNC Object
RNx (Radio Network) objects are just created once per RNC object with no identifiers
RNAC for Admission Control
RNFC for Feature Control (Enabling parameters for all features)
RNHSPA for High Speed Packet Access
RNMOBI for Mobility
RNPS for Packet Scheduler (DCH Packet Scheduler)
RNRLC for Radio Link Control (Mainly AM RLC parameters)
RNTRM for Transmission (Transport Bearer Tuning and Streaming QoS for HSPA)
WSG

WANE

WLCSE

CMOB

WSMLC

CBCI

PFL

RNC
RNAC
RNFC

RNPS
RNRLC

RNHSPA

RNTRM

RNMOBI

IUC
S
IUCSIP
7

Nokia Siemens Networks

RN31632EN40GLA0

IUP
S
IUPSIP

IUR

RNC Object
COSITE/COSRNC
COSITE object contains parameters which are of common significance to all co-site pairs within the RNC.
COSRNC object contains parameters which need to be individually configured for each RNC in co-site pair.
Co-siting objects can be created only after RNC along with all its sub-objects are created. [cRNC]

VCEL

Common configuration (virtual cell)


for all WCDMA and I-HSPA cells
controlled by neighboring network
elements
VCEL object has also a relation to
IUCS, IUPS, WRAB, FMCS/I/G and
HOPS/I/G objects.

VCEL

RNC
COSRNC

Various feature objects


IUx

IPQM

RNx

WRAB

HOPG

COCO

The maximum number of VCEL


objects in the RNW database is one.

IPNB

VCEL is an optional object.

TQM

HOPS

FMCS

ADJD

VBTS
Common configuration (virtual base
station) for all WCDMA and I-HSPA
base stations controlled by
neighboring network elements.

FMCI
FMCG

VBTS is an optional object.

The maximum number of VBTS


objects in the RNW database is one.
8

COSITE

VBTS

Nokia Siemens Networks

RN31632EN40GLA0

WBTS

WCEL

HOPI

ADJS
ADJI
ADJG/L

WAC

WBTS Object
The logical object of the WCDMA Base Station (Node B). A WBTS can have up to 24
WCDMA cells, and either 1 COCO (ATM transport) or 1 IPNB object (IP transport).
If Iub transport QoS is used, WBTS connects to 1 TQM object
VCEL

COSITE

VBTS

RNC
COSRNC

Various feature objects


IUx

IPQM

RNx

WRAB

HOPG

COCO

WBTS

IPNB
TQM

HOPI
HOPS

FMCS

ADJD

FMCI

WCEL

ADJS
ADJI

FMCG

ADJG/L
WAC
9

Nokia Siemens Networks

RN31632EN40GLA0

WCEL object
The logical object of the WCDMA Cell is created to define the configuration of the
WCDMA Node B site. In 1 RNC database there can be 2800 WCELs (or 4800 due to
RAN1795: RNC 2600 coverage optimization solution).
VCEL

COSITE

VBTS

RNC
COSRNC

Various feature objects


IUx

IPQM

RNx

WRAB

HOPG

COCO

WBTS

IPNB
TQM

HOPI
HOPS

FMCS

ADJD

FMCI

WCEL

ADJS
ADJI

FMCG

ADJG/L
WAC
10

Nokia Siemens Networks

RN31632EN40GLA0

Handover Path
HOPx

The Handover Path object stores mainly Cell Reselection & Intra-Frequency HHO
parameters. One HOPx can be related to several Adjacency objects.

The maximum number of HOPx objects within 1 category is 100.


E.g. for different type of cells (urban, rural, macro/micro/pico)
HOP Types:

VCEL

HOPS object for intra-frequency


Handover Path

COSITE

VBTS

RNC
COSRNC

Various feature objects

IUx

IPQM

RN
x

WRAB

HOPI object for inter-frequency


Handover Path

COCO

HOPG/L object for inter-system


Handover Path (GSM/LTE)

TQM

HOPS

FMCS

ADJD

IPNB

FMCI
FMCG

HOPG

WBTS

WCEL

HOPI

ADJS
ADJI
ADJG/L

WAC
11

Nokia Siemens Networks

RN31632EN40GLA0

HOPx Level Parameters


Intra Frequency

Inter Frequency

IntraFreqNcellHCSpriority

InterFreqNcellHCSpriority

GSMncellHCSpriority

IntraFreqNcellHCSthreshold

InterFreqNcellHCSthreshold

GSMncellHCSthreshold

IntraFreqNcellQqualMin

InterFreqNcellQqualMin

GSMncellQrxlevMin

IntraFreqNcellQrxlevMin

InterFreqNcellQrxlevMin

GSMncellPenaltyTime

IntraFreqNcellPenaltyTime

InterFreqNcellPenaltyTime

GSMncellQoffset1

IntraFreqNcellQoffset1

InterFreqNcellQoffset1

GSMncellTempOffset1

IntraFreqNcellQoffset2

InterFreqNcellQoffset2

HOPGId

IntraFreqNcellTempOffset1

InterFreqNcellTempOffset1

IntraFreqNcellTempOffset2

InterFreqNcellTempOffset2

EcNoAveragingWindow

HOPIId

Inter System

EnableInterRNCsho
EnableRRCRelease
HHOMarginAverageEcNo
HHOMarginPeakEcNo
ReleaseMarginAverageEcNo
ReleaseMarginPeakEcNo
HOPSId
Not a complete list
12

Nokia Siemens Networks

RN31632EN40GLA0

Idle Mode Parameters


Handover Parameters

Adjacencies
ADJx

Adjacencies for WCDMA cell refers to a Handover relationship between two cells.
They are defined for neighbouring cells.
ADJS object for intra-frequency Adjacency
ADJI object for inter-frequency Adjacency
ADJG/L object for inter-system Adjacency (GSM/LTE)
ADJD object for detected intra-frequency Adjacency
VCEL

VBTS

COSITE

RNC

COSRN
C

Various feature objects

IUx

IPQM

There can be:


31 intra frequency adjacencies (ADJS),
48 inter-frequency adjacencies (ADJI),
32 inter-system adjacencies (ADJG),
8 inter-system adjacencies (ADJL) &
32 detected intra-frequency adjacencies (ADJD)
Handover Path objects must be created before
ADJx can be used

Nokia Siemens Networks

RN31632EN40GLA0

WBTS

HOPI

TQM

HOPS

FMCS

ADJD

FMCI
FMCG

WCEL

ADJS
ADJI
ADJG/L

WAC
13

WRAB
HOPG

COCO
IPNB

RN
x

Adjacencies (ADJx)
Inter Frequency

Intra Frequency
IntraFreqNcellCI

InterFreqNcellCI

GSMncellBandIndicator

IntraFreqNcellEcNoOffset

InterFreqNcellLAC

GSMncellBCC

IntraFreqNcellDERR

InterFreqNcellTxPwrRACH

GSMncellBCCH

IntraFreqNcellLAC

InterFreqNcellMCC

GSMncellCI

IntraFreqNcellTxPwrRACH

InterFreqNcellMNC

GSMncellLAC

IntraFreqNcellMCC

InterFreqNcellMNCLength

GSMncellTxPwrMaxRACH

IntraFreqNcellMNC

NrtHopiIdentifier

GSMncellMCC

IntraFreqNcellMNCLength

InterFreqNcellScrCode

GSMncellMNC

HSDPAHopsIdentifier

InterFreqNcellRNCid

GSMncellNCC

NrtHopsIdentifier

InterFreqNcellRAC

NrtHopgIdentifier

IntraFreqNcellScrCode

RtHopiIdentifier

RtHopgIdentifier

IntraFreqNcellRNCid

InterFreqNcellTxDiv

ADJGId

IntraFreqNcellRAC

InterFreqNcellUARFCN

RtHopsIdentifier

ADJIId

IntraFreqNcellTxDiv
ADJSId

Not a complete list


14

Inter System

Nokia Siemens Networks

RN31632EN40GLA0

Detected Adjacencies (ADJD)


Intra Frequency
ADJDChangeOrigin (Change origin)
ADJDId (Identifier of additional intra-frequency
adjacency)
AdjdCI (Cell Identifier)
AdjdCPICHTxPwr (Primary CPICH power)
AdjdDERR (Disable Effect on Reporting Range)
AdjdHSDPAHopsId (HSDPA HOPS identifier)
AdjdLAC (Location Area Code)
AdjdMCC (Mobile Country Code)
AdjdMNC (Mobile Network Code)
AdjdMNCLength (Mobile Network Code
Length)
AdjdNRTHopsId (NRT HOPS Identifier)
AdjdRAC (Routing Area Code)AdjdRNCId (RNC
Identifier)
AdjdRTHopsId (RT HOPS Identifier)
AdjdRTWithHSDPAHopsId (HSDPA HOPS
identifier for AMR multi-service)
AdjdScrCode (Primary Scrambling Code)
AdjdTxDiv (Tx Diversity Indicator)

15

Nokia Siemens Networks

ADJD = detected adjacency


RN31632EN40GLA0
DSR: Detected Set Reporting

Detected Set Reporting & Measurements:


optional features related to ADJD allow UE to report &
handover to cells not included in the neighbor list
If feature RAN1191: Detected Set Reporting (DSR) &
Measurements is enabled, specific counters (M1028 Autodef
SHO DSR measurement) can be used to find detected set
cells that are reported by the UE but that are not in the ADJS
or ADJD adjacency lists and cannot therefore be targets of
SHO. With that information the neighbor lists can be optimized
to include such cells that would be good handover targets.

DSRepBasedSHO
Detected Set Reporting Based SHO
FMCS; 0 = DSR not allowed;
1 = DSR enabled, but SHO to detected cell not allowed
2 = DSR based SHO enabled
The parameter indicates whether the DSR based SHO is enabled in the cell.
When the Detected Set Reporting & Measurements feature (optional) is enabled in the
RNC, the parameter can have the following values::
0: DSR is not allowed.
1: DSR is enabled but SHO to detected cell is not allowed.
When the SHO based on the Detected Set Reporting feature (optional) is enabled in
the RNC, the parameter can have the following values:
0: DSR is not allowed.
2: DSR based SHO is enabled.

Adjacencies (ADJx) to HOPx


Every adjacency definition contains links to HOPx parameter sets
RtHopxIdentifier defines the HOPx (x = S, I, G) parameter set that is applied
Idle mode cell-reselections
RT bearer intra-frequency hard handovers

NrtHopxIdentifier defines the HOPx (x = S, I, G) parameter set that is applied


Connected mode cell-reselections (CELL_FACH, CELL_PCH, URA_PCH)
NRT bearer intra-frequency hard handovers

HSDPAHopsIdentifier defines the HOPS parameter set that is applied


For user having HS-DSCH allocated

RTWithHSDPAHopsIdentifier defines the HOPS parameter set that is applied


For user having HS-DSCH allocated simultaneously with AMR speech CS RAB

16

Nokia Siemens Networks

RN31632EN40GLA0

Frequency Measurement Control


The FMC object contains information concerning the frequency measurement
functionality of the RNC.
Max. number of frequency measurement control objects within 1 category: 100.
e.g. for different type of cells (urban, rural, macro/micro/pico)

1 FMC can be related to several WCDMA cells.


FMC Types:

VCEL

FMCS object for intra-frequency


Frequency Measurement Control
FMCI object for inter-frequency
Frequency Measurement Control

FMCG object for inter-system


Frequency Measurement Control

COSITE

VBTS

RNC
COSRNC

Various feature objects

IUx

IPQM

WRAB
HOPG

COCO
IPNB

RN
x

WBTS

HOPI

TQM

HOPS

FMCS

ADJD

FMCI
FMCG

WCEL

ADJS
ADJI
ADJG/L

WAC
17

Nokia Siemens Networks

RN31632EN40GLA0

FMCX Level Parameters

18

Threshold & Trigger

Handover Cause

ActiveSetWeightingCoefficient

IFHOcauseCPICHEcNo

GSMcauseCPICHEcNo

AdditionReportingInterval

IFHOcauseCPICHrscp

GSMcauseCPICHrscp

AdditionTime

IFHOcauseTxPwrDL

GSMcauseTxPwrDL

AdditionWindow

IFHOcauseTxPwrUL

GSMcauseTxPwrUL

EcNoFilterCoefficient

IFHOcauseUplinkQuality

GSMcauseUplinkQuality

DropTime

InterFreqDLTxPwrThrAMR

GsmDLTxPwrThrAMR

DropWindow

InterFreqDLTxPwrThrCS

GsmDLTxPwrThrCS

MaxActiveSetSize

InterFreqDLTxPwrThrNrtPS

GsmDLTxPwrThrNrtPS

ReplacementReportingInterval

InterFreqDLTxPwrThrRtPS

GsmDLTxPwrThrRtPS

ReplacementTime

InterFreqMaxMeasPeriod

GsmMaxMeasPeriod

ReplacementWindow

InterFreqMeasAveWindow

GsmMeasAveWindow

HHoEcNoCancel

InterFreqMeasRepInterval

GsmMeasRepInterval

HHoEcNoCancelTime

InterFreqMinHoInterval

GsmMinHoInterval

HHoEcNoThreshold

InterFreqMinMeasInterval

GsmMinMeasInterval

HHoEcNoTimeHysteresis

InterFreqNcellSearchPeriod

GsmNcellSearchPeriod

HHoRscpCancel

InterFreqUETxPwrFilterCoeff

GsmUETxPwrFilterCoeff

HHoRscpCancelTime

InterFreqUETxPwrThrAMR

GsmUETxPwrThrAMR

HHoRscpFilterCoefficient

InterFreqUETxPwrThrCS

GsmUETxPwrThrCS

HHoRscpThreshold

InterFreqUETxPwrThrNrtPS

GsmUETxPwrThrNrtPS

HHoRscpTimeHysteresis

InterFreqUETxPwrThrRtPS

GsmUETxPwrThrRtPS

IMSIbasedSHO

InterFreqUETxPwrTimeHyst

GsmUETxPwrTimeHyst

FMCSId

FMCIId

FMCGId

Nokia Siemens Networks

RN31632EN40GLA0

Not a complete list

WCEL to FMCx

4x3+1+1

Every WCEL definition contains links to max. 14 FMCx parameter sets


RtFmcxIdentifier (x = S, I, G) defines FMCx parameter set applied for radio links with
RT bearers
NrtFmcxIdentifier (x = S, I, G) defines FMCx parameter set applied for radio links with
only NRT bearers
HSDPAFmcxIdentifier (x = S, I, G) defines FMCx parameter set controlling
measurements of a user having HS-DSCH allocated
RTWithHSDPAFmcxIdentifier (x = S, I, G) defines FMCx parameter set controlling
measurements of a user having HS-DSCH allocated simultaneously with AMR
speech CS RAB

HSPAFmcsIdentifier defines FMCS parameter set controlling measurements of a user


having HS-DSCH & E-DCH allocated
RTWithHSPAFmcsIdentifier defines FMCS parameter set controlling measurements
of a user having HS-DSCH & E-DCH allocated + AMR speech CS RAB

19

Nokia Siemens Networks

RN31632EN40GLA0

WAC
WAC: WCEL Admission Control
Cell-specific UL load control parameters (better cope with high UL load mass events case)
Admission control parameters
Several state transition control parameters

VCEL

20 WAC objects can be configured


which include different sets of
parameters
Each of WCEL and VCEL (for anchoring
situations) can be associated with the
selected WAC object using pointer
WACSetIdentifier added to WCEL and VCEl
objects

COSITE

VBTS

RNC
COSRNC

Various feature objects

IUx

IPQM

WRAB
HOPG

COCO
IPNB

RN
x

WBTS

HOPI

TQM

HOPS

FMCS

ADJD

FMCI
FMCG

WCEL

ADJS
ADJI
ADJG/L

WAC
20

Nokia Siemens Networks

RN31632EN40GLA0

WAC related parameters


Parameters moved from RNC (RNC, RNAC, RNPS, RNHSPA) to WAC:

DCHUtilRelAveWin
DCHUtilRelThrDL
DCHUtilRelThrUL
DCHUtilRelTimeToTrigger
EDCHMACdFlowThroughputAveWin
EDCHMACdFlowThroughputRelThr
EDCHMACdFlowThroughputTimetoTrigger
HSDPAInitialBRULStrNRT
HSDPAMinBRULStrNRT
HSDPAinitialBitrateUL
HSDPAminAllowedBitrateUL
InactCPCBatOptT
InactCPCNoBatOptT
InactNonCPCBatOptT

InactNonCPCNoBatOptT
InactivityTimerDownlinkDCH (structure of 8 parameters)
InactivityTimerUplinkDCH (structure of 8 parameters)
MACdflowthroughputAveWin
MACdflowutilRelThr
MACdflowutilTimetoTrigger
MSActivitySupervision
PrxNoiseMaxTuneAbsolute
TrafVolPendingTimeDL
TrafVolPendingTimeUL
TrafVolThresholdULLow
UL_DL_activation_timer
WaitTimeRRC (structure of 12 parameters)

New Parameters added to WAC object:

WACId

WACChangeOrigin

New Parameter added to WCEL and VCEL:

WACSetIdentifier

Parameter moved from WCEL/VCEL to WAC object:

21

Nokia Siemens Networks

HSDPAMaxBitrateUL
RN31632EN40GLA0

COCO / IPNB
COCO: Connection Configuration
A new logical COCO object is created in order to reserve local transmission resources for the
WCDMA BTS.
The COCO objects display the transmission resources in the Iub interface, but not the actual
network topology
There can be up to 400 COCO objects in the RNW database
VCEL

COSITE

VBTS

RNC
COSRNC

Various feature objects

IPNB: IP Node B

IUx

IPQM

When IP transport is used on Iub, the


IPNB object collects related parameters
like:
IP address of NodeB

WRAB
HOPG

COCO
IPNB

RN
x

WBTS

HOPI

TQM

HOPS

SCTP port numbers of C-NBAP and DNBAP

FMCS

ADJD

DiffServ Code Points

FMCI
FMCG

WCEL

ADJS
ADJI
ADJG/L

WAC
22

Nokia Siemens Networks

RN31632EN40GLA0

TQM / WRAB
TQM: Transmission Quality Management
when Iub Transport QoS is used, the IPNB object provides Activity Factors for transport bearers and
mapping tables between various QoS parameters
The max number of TQM managed objects is 4.
VCEL

WRAB: WCEL RAB parameters


A WRAB object contains the connectionbased quality control parameters.
Parameters define the service bearer and
signaling bearer specific quality targets and
related power control thresholds for each
transport channel configuration
WCEL refers to WRAB via EbNoSetIdentifier
parameter
there can be 5 WRAB per RNC

COSITE

VBTS

RNC
COSRNC

Various feature objects

IUx

IPQM

WRAB
HOPG

COCO
IPNB

RN
x

WBTS

HOPI

TQM

HOPS

FMCS

ADJD

FMCI
FMCG

WCEL

ADJS
ADJI
ADJG/L

WAC

23

Nokia Siemens Networks

RN31632EN40GLA0

IPQM / CMOB
IPQM: IP Quality Management
is used, if IP transport is used on Iu interfaces
it maps traffic classes to DiffServ Code Points (DSCP) which are used to maintain transport QoS
there can be 8 IPQM per RNC, each IU object selects 1 IPQM as template

CMOB: Congestion Management OBject


contains parameters for the WCDMA RAN Access
Regulation feature
WSG
this allows to temporarily bar certain
IPQM
Access Classes from accessing the
network e.g. in case of disasters or
large events
acts only on Access Classes 0 to 9
CMOB-Congestion
Management object

24

Nokia Siemens Networks

ACBarredListSystem
CMOBChangeOrigin
CMOBId
CMOBTimeStamp
CellAccessRestriction
RestrictionGroupName
RestrictionGroupType
TrafficRestriction
RN31632EN40GLA0

WANE
CMOB

WLCSE

RNC
IUCS/IUPS

WSMLC
IUR

HOPG

COCO
IPNB

WRAB

WBTS

TQM

HOPI
HOPS
ADJD

FMCS
FMCI
FMCG
WAC

WCEL

ADJS
ADJI
ADJG/L

WANE & WSG / WSMLC & WLCSE Objects


IMSI BASED HO

LOCATION BASED SERVICE

WANE & WSG MO groups are for the IMSI Based HO, which is optional feature
WANE set contain PLMN id where UE is allowed to make handover.
WSG object should be created to every subscriber (PLMN id) visiting in network and it maps subscriber
(PLMN id) to certain WANE sets
WANEWCDMA
Authorised
Networks
Parameters

AuthorisedNetworkId
AuthorisedNetworkList
AuthorizedNetwork PLMN
AuthorizedNetworkMCC
AuthorizedNetworkMNC
AuthorizedNetworkMNCLength
Technology
WANEChangeOriging
WANEName

GSMRoaming
HomePLMN
HomePLMNMCC
HomePLMNMNC
HomePLMNMNCLength
OperatorName
SubscriberGroupid
WSGAuthorisedNetworkId
WSGChangeOriging

WSGWCDMA
subscriber
group
Parameters

- WSMLC & WLCSE object groups are for Location based service. LCS is RAN04 feature
- WSMLC: WCDMA Serving Mobile Location Center, represents a logical object with RNC specific
mobile location center parameters
- WLCSE: WCDMA Location service entity, represent a logical object with WCEL specific location
parameters
WSMLC-WCDMA
Serving
Mobile Location Center

25

Nokia Siemens Networks

ConfAreaLevel
RNCDelayTolRespTime
RNCLowDelayResponseTime
WSMLCChangeOrigin
WSMLCid
RN31632EN40GLA0

AntennaBearing; AntHPBW
WLCSE-WCDMA
AntennaCoord; CovType;
Location
Service Entity
EnvCharact; MaxCellBackRad
MaxCellRad; RepeaterExist
WLCSEChangeOrigin
WLCSEUtranCellId; WLCSEid

CBCI / PREBTS/ PFL


CBCI: Cell Broadcast Centre
CBCI object maintains the data to the cell broadcast centre used in the service area broadcast
features.
The maximum number of CBCI objects is 4.
CBCI parameters can be configured only if Service Area Broadcast Protocol (SABP) is in use.

PFL: Preferred Frequency Layer


PFL object is created in order to define
preferred frequency layers for different UE
capability and service combinations
The PFL object can be created only when
feature RAN2172: Multi-Band Load
Balancing has been installed in the RCN.

PFL object is under RNC object.


Max number of PFL objects is 50 in the
RNC

WSG

WANE

WLCSE
WSMLC

CMOB

PFL

CBCI

RNC
RNAC
RNPS

RNFC

RNRLC

RNHSPA

RNTRM

RNMOBI

IUCS

26

Nokia Siemens Networks

RN31632EN40GLA0

IUCSIP

IUP
S
IUPSIP

IUR

HOPS parameters could be


defined on a Target cell
type basis (e.g. urban, rural,
macro/micro/pico)

Summary

NrtHopsIdentifier = 1

HOPS
(RTwHSDPA)

RtHopsIdentifier = 2

HOPSid = 3

HSDPAHopsIdentifier = 6

WCEL

WBTS

Nokia Siemens Networks

HOPS
(RT)

HOPSid = 2

ADJSid = 1

HOPS
(HSDPA)

HOPSid = 6

& 2 for HSDPA, sets can be reused for other cells.)

HSDPAFmcsIdentifier = 50

27

ADJS

Each ADJS has associated 1 HOPS for NRT, 1 for RT

WCEL

RtFmcsIdentifier = 40

FMCS parameters could be


defined on a Serving cell type
basis (e.g. urban, rural,
macro/micro/pico)

HOPSid = 1

WCEL

NrtFmcsIdentifier = 3

Each WCEL has


associated 1 FMCS
for NRT & 1 for RT &
2 for HS(D)PA, all
can be reused for
other cells.

HOPS
(NRT)

RTwithHSDPAHopsIdentifier = 3

FMCSid = 1

FMCS
(NRT)

FMCSid = 1

FMCS
(RT)

FMCSid = 2

FMCSid = 2

RN31632EN40GLA0

FMCS
(HS(D)PA)
FMCS
(RT&HS(D)PA)

HOPS
(NRT)

HOPSid = 1

ADJD

HOPS
(RT)

HOPSid = 5

ADJDid = 1

HOPS
(HSDPA)

HOPSid = 7

HOPS
(RTwHSDPA)

HOPSid = 3

Parameter count
MO Class
ADJD
ADJG
ADJI
ADJL
ADJS
CBCI
CMOB
COCO
COSITE
COSRNC
FMCG
FMCI
FMCS
HOPG
HOPI
HOPL
HOPS
IPNB
IPQM
IUCS
IUCSIP
IUO
IUPS
IUPSIP
IUR
PFL
RNAC
RNC
RNFC
RNHSPA
RNMOBI
RNPS
RNRLC
RNTRM
TQM
VBTS
VCEL
WAC
WANE
WBTS
WCEL
WLCSE
WRAB
WSG
WSMLC
Grand Total

28

HC

SI

PS

AC

Group
PC

LC

Ident

Other

Grand Total

16
15
21
1
19
0
0
0
0
0
30
25
25
11
14
4
7
0
0
0
0
0
0
0
2
92
0
2
13
11
61
0
0
0
0
7
31
0
7
6
97
0
0
8
0
525

0
0
0
2
0
0
2
0
0
0
0
0
0
0
9
0
9
0
0
0
0
2
0
0
0
0
0
24
1
0
0
0
0
0
0
0
0
0
0
0
73
0
0
0
0
122

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
0
0
0
0
0
0
0
2
0
0
0
15
184
11
100
2
0
0
1
8
38
0
11
97
0
0
0
0
471

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
0
0
2
0
54
5
9
27
8
0
196
0
0
1
8
16
0
33
101
0
96
0
0
558

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
26
0
2
0
2
0
0
0
0
0
1
0
0
0
28
0
0
0
0
59

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
0
1
0
0
0
0
0
0
0
0
1
0
6
26
0
0
0
0
43

1
1
1
1
1
1
1
2
1
3
1
1
1
1
1
1
1
0
1
6
1
16
7
0
4
1
1
7
1
1
1
1
1
1
0
1
3
1
0
9
14
5
1
0
1
105

1
1
1
1
1
6
4
119
2
7
1
1
1
1
1
1
1
16
7
15
5
9
13
6
29
1
3
51
15
8
11
1
1
103
139
1
2
3
1
67
57
23
1
1
32
771

18
17
23
5
21
7
7
121
3
10
32
27
27
13
25
6
20
16
8
21
6
29
20
6
39
94
93
89
57
231
94
102
200
104
139
11
53
59
8
132
493
28
98
9
33
2654

Nokia Siemens Networks

RN31632EN40GLA0

Ref: RNC Common


Production 2.0
parameter dictionary
2654 visible
parameters for cRNC
product (RN7.0)
470 hidden
parameters for cRNC
product (RN7.0)

Parameter Dictionary
RAS06 Example:

Parameters & Values


described in the following:
PtxPrimaryCPICH
-10..50; 0.1; 33 dBm
(Range; Step; Default)

29

Nokia Siemens Networks

RN31632EN40GLA0

Parameter management - Overview


Radio network parameters are managed via Netact OSS or directly via Element
Manager functionality
Usage of Netact plan
edit, analysis and
activation tools
recommended

Netact CM tools
OMS Element Manager
new in RU30
Netact
Database

Recommended
RNW
Database

30

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI - General

31

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI - Fields

Parameter group tabs


32

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example


An overview page can be opened for WBTSs within RNC-26 by right-clicking on
WBTSs object on the objects pane on left (new tab for this page is added above)

33

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example (Main parameters -RNC)


Main parameters of the selected object can be viewed by right-clicking on the
object on left pane and click on Show main parameters

34

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example (Main parameters - RNC)


Accordingly below tab will be shown; for the main parameters of RNC-26

35

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example (All parameters - FMCS)


Similarly; all parameters can be shown or edited as follows in FCMS-1

36

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example (Edit parameters)


After clicking on Edit parameters; parameters can be editable as shown

37

Nokia Siemens Networks

RN31632EN40GLA0

OMS Element Manager GUI Example (RNFC)


RNFC (Radio Network Feature Control), as an RU30 new object; contains all the
enabling (switch) parameters for all the supported features.

38

Nokia Siemens Networks

RN31632EN40GLA0

You might also like