PneumaCare Series Features

PneumaCare
Single Limb

MODE

*Single Limb*
Ex-Valve

PneumaCare02
Single Limb

*Single Limb*
Ex-Valve

PACV
PSIMV
VACV
VSIMV
Spont+
PRVC
O2Stream
ACPAP+
ABIPAP+

Trend

Trend (72hrs)

Peripherals

High Pressure Oxygen Mixer


Low Flow Oxygen Supply Inlet
Exhalation Drive Line Input
Proximal Pressure Line Input

Optional

Nasal Cannula for O2Stream


SpO 2
EtCO 2
Remark : *single limb * - Single limb circuit with external exhalation valve

Head Office / 1st Factory

Branch Office / 2nd Factory

Industrial Zone 861-10, Toegye-dong, Chuncheon-si,


Gangwon-do, Korea
(ZIP code 200-944)

5th Floor, A-dong, Woolimlionsvalley 5th.


#144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si,
Gyeonggi-do, South Korea (ZIP code 462-739)

TEL: +82. 70. 7119. 2540


FAX: +82. 33. 264. 5999
e-mail: sales@mek-ics.com
www.mek-ics.com

TEL: +82. 70. 7119. 2520


FAX: +82. 31. 735. 2761
e-mail: sales@mek-ics.com
www.mek-ics.com

0470

MTV 1000

Transport Ventilator for

Acute Care, Sub-Acute Care,


Homecare and Transport

PneumaCare Series
(Single limb circuit use)
PneumaCare
PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS),
PRVC, ACPAP+, ABiPAP+
Optional : SpO2, EtCO2

Encorder for setting parameter


7 Color TFT Touch Screen

PneumaCareO2
PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS),
PRVC, ACPAP+, ABIPAP+,
O2 Stream with high flow oxygen supply.
With High Pressure Oxygen Mixer
Optional : SpO2, EtCO2, Nasal Cannula for O2Stream

LAN, USB RS-232 Upgrade port

Proximal Pressure Line Input


Exhalation Drive Line Outlet

Built in a High Performance


Blower System

Optional : SpO2, EtCO2

ACPAP+
(Adaptive CPAP Plus Pressure Support)

Hospital.

Home Care.

Transport.

[ACPAP+ Function]
It is developed with high technology which applying
to the highest class ICU ventilator and applying for a
patent. It is innovated reaserch object comfortable
breathing in CPAP. MEKICS created unique ACPAP+
technology completed the clinical effect and comfortable
breathing simultaneous.
[Principal]
Based on the CPAP, it is contrived to minimize of
breaths with difficulty in CPAP as induction of airway
open, pressure support that is decreased patients
effort in inspiration, and active break (rapid pressure
interruption) that makes easy of expiration.

PSV

[Technology]
It is decreased Inspiratory Phase Work of Breathing through
Inspiratory Trigger function and Pressure Support function. It
makes possible to inhalation with small effort of patient (WOB_
inspiration). It is decreased Expiratory Phase Work of Breathing
through Ex_Sesnse. In this time, interrupt the flow rapidly and
supply brk_time (Expiration Break Time). It makes possible to
exhalation with small effort of patient (WOB_expiration) and
minimize of breaths with difficulty.
* (brk_time: Expiration Break Time): Application to most
convenience respiration pattern.

Quick Pause
Pressure

=Easy Expiration

Trigger
Flow-Machine
Ex.time
Flow-Patient