You are on page 1of 5

LINE CARD

Grounding Exothermic Lightning Protection

Lightning Protection
Equipment

Manufacturing Engineering Services Training


Harger Lightning & Grounding 301 Ziegler Drive Grayslake, IL 60030 Phone: 800-842-7437 Fax: 847-548-8755 www.harger.com

Typical Roof Lightning Protection Layout

UNIVERSAL AIR TERMINAL BASE


MOUNTED VERTICALLY
(WITH FASTENERS ON PARAPET)

UNIVERSAL AIR TERMINAL BASE


MOUNTED HORIZONTALLY
(WITH ADHESIVE ON ROOF)

UNIVERSAL AIR TERMINAL BASE


MOUNTED HORIZONTALLY
(ON MECHANICAL UNIT)

AIR TERMINAL PIPE RAILING BASE

MAIN SIZE LIGHTNING


PROTECTION CONDUCTOR

Harger Lightning & Grounding 301 Ziegler Drive Grayslake, IL 60030 Phone: 800-842-7437 Fax: 847-548-8755 www.harger.com

GROUND ROD AND


NO. 305 GROUND ROD CLAMP

Harger Lightning & Grounding 301 Ziegler Drive Grayslake, IL 60030 Phone: 800-842-7437 Fax: 847-548-8755 www.harger.com

Lightning Protection Equipment


1 thru 4 - Copper Air Terminals

Listed 96

Part No.

Diameter

Length

Class

3812CUAT

3/8

12

3824CUAT

3/8

24

1212CUAT

1/2

12

II

28-50COIL

28

14 AWG

115,000

1224CUAT

1/2

24

II

28-100

28

14 AWG

115,000

5812CUAT

5/8

12

II

28-250

28

14 AWG

115,000

5824CUAT

5/8

24

II

5 - Class II - Copper Conductors

Diameter

Length

Class

1212ALAT

1/2

12

1224ALAT

1/2

24

5812ALAT

5/8

12

II

5824ALAT

5/8

24

II

Strand
Size

X-Sectional
Area in CM

Approximate diameter is 1/2.


Electro Tin Plated conductor also available.

1 thru 4 - Aluminum Air Terminals


Part No.

No. of
Strands

Part No.

Listed 96

5 - Class I - Aluminum Conductors


No. of
Strands

Part No.

For nickel or tin plated air terminals add


Listed 96
suffix N for nickel and suffix T for tin.
Other air terminal sizes available. Please contact factory.

Strand
Size

X-Sectional
Area in CM

A24-50COIL

24

14 AWG

98,600

A24-100

24

14 AWG

98,600

A24-250

24

14 AWG

98,600

Approximate diameter is 7/16.


Listed 96
A37R (rope lay)

Listed 96

5 - Class II - Aluminum Conductors

1 thru 3 - Air Terminal Bases

No. of
Strands

Part No.

Strand
Size

X-Sectional Approx.
Area in CM
Dia.

Part No.

Material

Internally Threaded
Hub Diameter

A37R-50COIL

37

13 AWG

192,000

19/32

CUBU38I

Copper

3/8

A37R-100

37

13 AWG

192,000

19/32

CUBU12I

Copper

1/2

A37R-250

37

13 AWG

192,000

19/32

CUBU58I

Copper

5/8

AUBU12I

Aluminum

1/2

AUBU58I

Aluminum

5/8

Listed 96

Add prefix T for elctro-tin plated bronze base.


Accepts #14 bonding conductor up thru Class II
main lightning conductor.

6 - Cable Clips

4 - Pipe Railing Bases

Part No.

Material

Fits Lightning
Conductors

Fits Grounding
Conductors
N/A

Part No.

Material

Air Terminal
Diameter

ACC2

Aluminum

A28 & A24

ACC4

Aluminum

A37R

N/A

CPRB1.5/2AT38*

ETPB**

3/8

CCC1

Copper

#14

2 Str., 4 Str., 2 Sol.

CPRB1.5/2AT12*

ETPB**

1/2

CCC2

Copper

29 & 32

1/0 Str. & 2/0 Str.

CPRB1.5/2AT58*

ETPB**

5/8

CCC3

Copper

28 & 24

4/0

APRB1.5/2AT12*

Aluminum

1/2

APRB1.5/2AT58*

Aluminum

5/8

* Nominal pipe size range 1.25 - 2


**Electro Tin Plated Bronze
Fits all main size conductors up to 9/16 diameter.
Other sizes available. Please contact factory.
Air terminal not included.
Listed 96

5 - Class I - Copper Conductors


No. of
Strands

Strand
Size

X-Sectional
Area in CM

29-50COIL

29

16 AWG

72,500

29-100

29

16 AWG

72,500

29-250

29

16 AWG

72,500

Part No.

Approximate diameter 3/8.


Electro Tin Plated conductors also available.

Electro Tin Plated clips also available.


Listed 96

7a - Cable Holders
Part No.

Material

262

Stamped Copper

A262

Aluminum

Listed 96

For use with all cables thru 4/0 or up to 9/16 diameter.


Electro Tin Plated copper holders also available.

7b - Cable Holders

Listed 96

Part No.

Material

Fits Conductor

A263X2

Aluminum

A28, A24

A263X4

Aluminum

A37R

For use with all Class I & Class II lightning conductors.


For penetration-free adhesive mounting on horizontal or
vertical metal surfaces.

Harger Lightning & Grounding 301 Ziegler Drive Grayslake, IL 60030 Phone: 800-842-7437 Fax: 847-548-8755 www.harger.com

Lightning Protection Equipment


Listed 96
Listed 467

Listed 96
Listed 467

8 - 1 Bolt Parallel Connectors


Part No.

Material

Class

B1BC

Copper

II

A1BC

Aluminum

II

TB1BC

ETPB*

13 - Bonding Plate
Part No.

Material

Class

217

ETPB*

II

* Electro Tin Plated Bronze


Accepts all main size conductors up to 9/16 diameter.
Over 8 square inches of bonding surface.

II

* Electro Tin Plated Bronze


Accepts all main size conductors up to 5/8 diameter.

M-1

truc
tu
eala ral
nt

Listed 96

14 - M-1 Structural Sealant

9 - Bi-Metal 1 Bolt Parallel Connector


Part No.

Material

Class

BM1BC

Bi-Metal

II

2 x 1-1/2 bi-metal connector allows splicing


of aluminum conductors to copper conductors.

Listed 96

Material

Class

211R

Bi-Metal

II

Color
Black

M1-10OZ-G

Gray

M1-10OZ-L

Limestone

M1-10OZ-W

White

10.1 fluid oz. cartridge.


Application coverage (per tube) is approximately
15 cable holders or 5 bases.
For use on metal, masonry and wood. Not for use
on TPO or hypolon roofs.
Install on clean surfaces in temperatures not
below 30F.

10 - Bi-Metal Connector
Part No.

Part No.
M1-10OZ-B

Brass side accepts all main size conductors


up to 17/32 diameter.
Aluminum side accepts all main size
conductors up to 19/32 diameter.

Listed 96
Listed 467

11 - Thru-Roof Assemblies
Part No.

Description

SSTRCC15812
SSTRCC15824

Vertical, Stainless Steel

SSTRACBM15812
SSTRACBM15824

Vertical, Stainless
Steel, Bi-Metal

15 - Ground Rod Clamp


Riser
Length

Part No.

Ground Rod
Size

Conductor
Range

12

305

Up thru 1

#6 AWG - 500 MCM

24
12
24

Other sizes available. Please contact factory.

Listed 96

Stainless Steel U bolt for strength and corrosion


resistance.
Provides over 1-1/2 of contact between the ground
electrode and conductors.
Accomodates two horizontal conductors thru 250 MCM.
Accomodates one vertical conductor up to 500 MCM.

15 - Copper Clad Steel Ground Rods


12 - Pipe Clamps

Part No.

Size

Material

1210

1/2 x 10

Yes

CPC*

Copper

588

5/8 x 8

Yes

APC*

Aluminum

5810

5/8 x 10

Yes

3410

3/4 x 10

Yes

110

1 x 10

Yes

Part No.

Conductor range #6 Solid thru 250 MCM.


Pipe outside diameter range .375 to 6.63.
* 6 clamps fit these pipe sizes.

Listed 96
Listed 467

UL Mark

Listed 467

Harger Lightning & Grounding 301 Ziegler Drive Grayslake, IL 60030 Phone: 800-842-7437 Fax: 847-548-8755 www.harger.com

Other Harger Products / Services


Grounding Busbars

Fence Grounding

Wireless Communication Equipment

Grounding Connectors

Ultraweld Exothermic Connections


featuring UltraShot & NUWTube

Supplementary Bonding Grids


aka Signal Reference Grids

Specialized Ground Electrodes

Data-Com Bonding & Grounding

Lightning Protection Installation Training

Harger Lightning & Grounding

301 Ziegler Drive Grayslake, IL 60030


Phone: 800-842-7437 Fax: 847-548-8755
Website: www.harger.com Email: hargersales@harger.com