You are on page 1of 80

PVG 32

Proportional Valves
Technical
Information

PVG 32 Proportional Valve


Technical Information
Contents
Revision History

Table of Revisions
Date
'FC
"QS
.BZ
+VO
%FD

Page
Various
67
5, 26
69


Changed
Handle on drawings
%PVCMFQBSBHSBQIEFMFUFE NJTTQFMMJOH
Code numbers changed
New back cover

Rev
GA
GB
GC
(%
(&

General

General ...................................................................................................................................................................................4

Function

Function .................................................................................................................................................................................7
PVG 32 valve group ...............................................................................................................................................................................7
PVPC, plug for external pilot oil supply..........................................................................................................................................9
17.3, friction detent ......................................................................................................................................................................... 
PVMF, mechanical float position lock ......................................................................................................................................... 
PVBS, main spools for flow or pressure control ....................................................................................................................... 2
PVPX, electrical LS unloading valve .............................................................................................................................................. 3

Technical Data

Technical data .................................................................................................................................................................... 4


PVG 32, valve group .................................................................................................................................................... 4
PVH, hydraulic actuation ........................................................................................................................................... 4
PVM, mechanical actuation...................................................................................................................................... 5
17&, electrical actuation ........................................................................................................................................... 6
17&, electrical actuation ........................................................................................................................................... 7
17&PJMDPOTVNQUJPO .................................................................................................................................................. 
PVPX, electrical LS unloading valve ...................................................................................................................... 9

Electrical Actuation

&MFDUSJDBMBDUVBUJPO .......................................................................................................................................................... 
Function .......................................................................................................................................................................... 

Modules and
Code Numbers

Modules and code numbers ........................................................................................................................................ 26


PVP, pump side modules ................................................................................................................................................................. 26
PVPV/PVPVM pump side modules ................................................................................................................................................ 
PVB, basic modules without adjustable LSA/B pressure limiting valves ....................................................................... 29
PVB, basic modules with adjustable LSA/B pressure limiting valves .............................................................................. 
PVM, mechanical actuation ............................................................................................................................................................. 
17.%cover for mechanical actuation ........................................................................................................................................ 
PVH, cover for hydraulic actuation................................................................................................................................................ 
17.3 DPWFSGPr friction detent ...................................................................................................................................................... 
PVMF,cover for mechanical float position .................................................................................................................................. 
17&, electrical actuation ................................................................................................................................................................... 32
PVLA, suction valve............................................................................................................................................................................. 33
PVLP, shock and suction valve ........................................................................................................................................................ 33
PVS, end plate ....................................................................................................................................................................................... 34
PVAS, assembly kit .............................................................................................................................................................................. 34
PVPX, electrical LS unloading valve .............................................................................................................................................. 35
PVPC, plug for external pilot oil supply....................................................................................................................................... 35
4BVFS%BOGPTT"MMSJHIUTSFTFSWFE
4BVFS%BOGPTTBDDFQUTOPSFTQPOTJCJMJUZGPSQPTTJCMFFSSPSTJODBUBMPHT CSPDIVSFTBOEPUIFSQSJOUFENBUFSJBM4BVFS%BOGPTTSFTFSWFTUIFSJHIUUP
alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting
BHSFFETQFDJDBUJPOT"MMUSBEFNBSLTJOUIJTNBUFSJBMBSFQSPQFSUJFTPGUIFJSSFTQFDUJWFPXOFST4BVFS%BOGPTT UIF4BVFS%BOGPTTMPHPUZQF UIF
4BVFS%BOGPTT4JDPO 1-64  8IBUSFBMMZNBUUFSTJTJOTJEFBOE,OPX)PXJO.PUJPOBSFUSBEFNBSLTPGUIF4BVFS%BOGPTT(SPVQ
'SPOUQBHF1 1 1 ' %SBXJOHBJ

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Contents
Contents
(Continued)
Technical
characteristics

Technical characteristics ............................................................................................................................................... 36


PVP, pump side module .................................................................................................................................................................... 36
PVB, basic module............................................................................................................................................................................... 37
PVLP, shock and suction valve ........................................................................................................................................................ 44
Pressure control spools ..................................................................................................................................................................... 46
Characteristics for float position main spools........................................................................................................................... 47

Dimensions

%JNFOTJPOT ........................................................................................................................................................................ 49

Lever Positions

Lever positions ................................................................................................................................................................. 53

Hydraulic Systems

Hydraulic systems ........................................................................................................................................................... 54

Electrical Systems

&MFDUSJDBMTZTUFNT ............................................................................................................................................................ 55

System Safety

System safety .................................................................................................................................................................... 57

Other Operating
Conditions

Other operating conditions .................................................................................................................................................................. 62

Module Selection Chart

Module selection chart .......................................................................................................................................................................... 64

Order Specification

Order specification................................................................................................................................................................................... 72

Specification Sheet

Specification sheet................................................................................................................................................................................... 76

Specification Sheet,
SAE Version

SpeciDBUJPOTIFFU 4"&WFSTJPO ......................................................................................................................................................... 77

Rated Pressure

Product

Rated pressure

PVG 32 w. PVS
PVG 32 w. PVSI
PVG 32 w. PVBZ
PVG 32 w. HIC steel
PVG 32 w. HIC aluminium
17(X174
17(X174*
17(X174
17(X174*

CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>
CBS<QTJ>

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
General
General

Valve system
PVG 32 is a hydraulic load sensing valve designed to give
maximum flexibility. From a simple load sensing directional
WBMWF UPBOBEWBODFEFMFDUSJDBMMZDPOUSPMMFEMPBEJOEFQFOEFOU
proportional valve.
The PVG 32 module system makes it possible to build up a
valve group to meet requirements precisely.The compact external dimensions of the
valve remain unchanged whatever combination is specified.
General features PVG 32
 -PBEJOEFQFOEFOUPXDPOUSPM
Oil flow to an individual function is independent of the load pressure of this function
Oil flow to one function is independent of the load pressure of other functions
Good regulation characteristics
 &OFSHZTBWJOH
 6QUPCBTJDNPEVMFTQFSWBMWFHSPVQ
Several types of connection threads
Low weight
PVP pump side module
 #VJMUJOQSFTTVSFSFMJFGWBMWF
 4ZTUFNQSFTTVSFVQUPCBS<QTJ>
Pressure gauge connection
Versions:
Open centre version for systems with fixed displacement pumps
Closed centre version for systems with variable displacement pumps
Pilot oil supply for electrical actuator built into the pump side module
Versions prepared for electrical LS unloading valve PVPX
PVB, basic module
Interchangeable spools
 %FQFOEJOHPOSFRVJSFNFOUTUIFCBTJDNPEVMFDBOCFTVQQMJFEXJUI
Integrated pressure compensator in channel P
Check valve in channel P
Shock/suction valves
LS pressure limiting valves individually adjustable for ports A and B
 o %JFSFOUTQPPMWBSJBOUT
Actuation modules
The basic module is always fitted with mechanical actuator PVM, which can be combined
with the following as required:
__
 &MFDUSJDBMBDUVBUPS 7 )
 o 17&4oQSPQPSUJPOBM TVQFS
 o 17&)oQSPQPSUJPOBM IJHIQFSGPSNBODF
 17&"QSPQPSUJPOBMMPXIZTUFSFTJT
 o 17&.oQSPQPSUJPOBM NFEJVNQFSGPSNBODF
 o 17&0o0/0''
 17.% DPWFSGPSNFDIBOJDBMBDUVBUJPO
 17.3 DPWFSGPSNFDIBOJDBMEFUFOU
PVMF, cover for mechanical float
PVH, cover for hydraulic actuation

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
General
Accessories

Remote control units


 &MFDUSJDBMSFNPUFDPOUSPMVOJUT
 o 173& 173&5
 o 173& o 173&4
 o 1SPG
 o 1SPG$*1
Hydraulic remote control unit
 o 173))
Electronics
 &)' PXBEKVTUNFOUVOJU
 &)3 SBNQHFOFSBUPS
 &)4 TQFFEDPOUSPM
 &)4$ DMPTFEMPPQTQFFEDPOUSPM
 &)" BMBSNMPHJD
 &)$ DMPTFEMPPQQPTJUJPODPOUSPM
PVG CIP
CIP Configuration Tool

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Notes
Notes

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVG 32 Valve Group with
Open Centre PVP
(PVB with Flow Control
Spool)

8IFOUIFQVNQJTTUBSUFEBOEUIFNBJOTQPPMTJOUIFJOEJWJEVBMCBTJDNPEVMFT 
BSFJO
the neutral position, oil flows from the pump, through connection P, across the pressure
BEKVTUNFOUTQPPM 
UPUBOL5IFPJMPXMFEBDSPTTUIFQSFTTVSFBEKVTUNFOUTQPPM
EFUFSNJOFTUIFQVNQQSFTTVSF TUBOECZQSFTTVSF

8IFOPOFPSNPSFPGUIFNBJOTQPPMTBSFBDUVBUFE UIFIJHIFTUMPBEQSFTTVSFJTGFE
UISPVHIUIFTIVUUMFWBMWFDJSDVJU 
UPUIFTQSJOHDIBNCFSCFIJOEUIFQSFTTVSFBEKVTU
NFOUTQPPM 
BOEDPNQMFUFMZPSQBSUJBMMZDMPTFTUIFDPOOFDUJPOUPUBOL
1VNQQSFTTVSFJTBQQMJFEUPUIFSJHIUIBOETJEFPGUIFQSFTTVSFBEKVTUNFOUTQPPM 

5IFQSFTTVSFSFMJFGWBMWF 
XJMMPQFOTIPVMEUIFMPBEQSFTTVSFFYDFFEUIFTFUWBMVF 
diverting pump flow back to tank.
*OBQSFTTVSFDPNQFOTBUFECBTJDNPEVMFUIFDPNQFOTBUPS 
NBJOUBJOTBDPOTUBOU
pressure drop across the main spool both when the load changes and when a module
with a higher load pressure is actuated.
8JUIBOPOQSFTTVSFDPNQFOTBUFECBTJDNPEVMFJODPSQPSBUJOHBMPBEESPQDIFDLWBMWF

JODIBOOFM1 UIFDIFDLWBMWFQSFWFOUTSFUVSOPJMPX
The basic module can be supplied without the load drop check valve in channel P for
GVODUJPOTXJUIPWFSDFOUSFWBMWFT
5IFTIPDLWBMWFT17-1 
XJUIYFETFUUJOHBOEUIFTVDUJPOWBMWFT17-" 
POQPSUT
A and B are used for the protection of the individual working function against overload
and/or cavitation.
"OBEKVTUBCMF-4QSFTTVSFMJNJUJOHWBMWF 
DBOCFCVJMUJOUPUIF"BOE#QPSUTPG
QSFTTVSFDPNQFOTBUFECBTJDNPEVMFTUPMJNJUUIFQSFTTVSFGSPNUIFJOEJWJEVBMXPSLJOH
functions.
The LS pressure limiting valves save energy compared with the shock valves PVLP:
 8JUI17-1BMMUIFPJMPXUPUIFXPSLJOHGVODUJPOXJMMCFMFEBDSPTTUIFDPNCJOFE
shock and suction valves to tank if the pressure exceeds the fixed setting.
 8JUI-4QSFTTVSFMJNJUJOHWBMWFTBOPJMPXPGBCPVUMNJO<64HBMNJO>XJMMCFMFE
across the LS pressure limiting valve to tank if the pressure exceeds the valve setting.

PVG 32 Valve Group with


Closed Centre PVP
(PVB with Flow Control
Spool)

*OUIFDMPTFEDFOUSFWFSTJPOBOPSJDF 
BOEBQMVH 
IBWFCFFOUUFEJOTUFBEPGUIF
QMVH 
5IJTNFBOTUIBUUIFQSFTTVSFBEKVTUNFOUTQPPM 
XJMMPOMZPQFOUPUBOLXIFO
UIFQSFTTVSFJODIBOOFM1FYDFFETUIFTFUWBMVFPGUIFQSFTTVSFSFMJFGWBMWF 

In load sensing systems the load pressure is led to the pump regulator via the LS
DPOOFDUJPO 

In the neutral position the pump control sets the displacement so that leakage in the
TZTUFNJTDPNQFOTBUFEGPS UPNBJOUBJOUIFTFUTUBOECZQSFTTVSF
8IFOBNBJOTQPPMJTBDUVBUFEUIFQVNQSFHVMBUPSXJMMBEKVTUUIFEJTQMBDFNFOUTPUIBU
the set differential pressure between P and LS is maintained.
5IFQSFTTVSFSFMJFGWBMWF 
JO171TIPVMECFTFUBUBQSFTTVSFPGBQQSPYCBS<QTJ>
BCPWFNBYJNVNTZTUFNQSFTTVSF TFUPOUIFQVNQPSFYUFSOBMQSFTTVSFSFMJFGWBMWF


520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVG 32
Sectional Drawing

P
3
M

PVP
4+5
A

LS
8
9
12 7

PVB

13

11
10

14

16

LS B

P LS A
17 15
A

B
T

PVB

19

18

20
V310106.A

  1SFTTVSFSFMJFGWBMWF

 .BJOTQPPM

2. Pressure reduction valve for pilot oil supply

 -4QSFTTVSFMJNJUJOHWBMWF

3. Pressure gauge connection


4. Plug, open centre

 4IPDLBOETVDUJPOWBMWF 17-1


 1SFTTVSFDPNQFOTBUPS

5. Orifice, closed centre

 -4DPOOFDUJPO QPSU"

6. Pressure adjustment spool

 -4DPOOFDUJPO QPSU#


 4VDUJPOWBMWF 17-"

7. Plug, closed centre


  -4DPOOFDUJPO
9. LS signal

 -PBEESPQDIFDLWBMWF
 1JMPUPJMTVQQMZGPS17&

 4IVUUMFWBMWF

 .BYPJMGMPXBEKVTUNFOUTDSFXTGPS
ports A and B

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVPC,
Plug for External Pilot Oil
Supply

PVPC with check valve for open centre PVP


PVPC with check valve is used in systems
where it is necessary to operate the
PVG 32 valve by means of the electrical
remote control without pump flow.
8IFOUIFFYUFSOBMTPMFOPJEWBMWFJT
opened, oil from the pressure side of the
cylinder is fed via the PVPC through the
pressure reducing valve to act as the pilot
supply for the electrical actuators.
This means that a load can be lowered by
means of the remote control lever without
TUBSUJOHUIFQVNQ5IFCVJMUJODIFDLWBMWFQSFWFOUTUIFPJMGSPNPXJOHWJBUIFQSFTTVSF
BEKVTUNFOUTQPPMUPUBOL8JUIUIFQVNQGVODUJPOJOHOPSNBMMZUIFFYUFSOBMTPMFOPJE
valve is closed to ensure that the load is not lowered due to the pilot supply oil flow
SFRVJSFNFOUPGBQQSPYJNBUFMZMNJO<64HBMNJO>

8JUIDMPTFEDFOUSF171UIFFYUFSOBMQJMPUPJMTVQQMZDBOCFDPOOFDUFEUPUIFQSFTTVSF
gauge connection without the use of a PVPC plug.

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVPC,
Plug for External Pilot Oil
Supply

PVPC without check valve


for open or closed centre PVP
PVPC without check valve is used in
systems where it is necessary to supply
the PVG 32 valve with oil from a manually
operated emergency pump without
directing oil flow to the pilot oil supply
PJMDPOTVNQUJPOBCPVUMNJO

<64HBMNJO>
8IFOUIFNBJOQVNQJTXPSLJOHOPS
mally, the oil is directed through the PVPC
plug via the pressure reduction valve to
the electrical actuators.
8IFOUIFNBJOQVNQPXGBJMT UIFFYUFSOBMTIVUUMFWBMWFFOTVSFTUIBUUIFPJMPXGSPN
the manually operated emergency pump is used to pilot open the over centre valve and
lower the load. The load can only be lowered using the mechanical operating lever of the
PVG 32 valve.

10

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVMR,
Friction Detent

PVMR, Friction Detent


5IFGSJDUJPOEFUFOU17.3BMMPXTUIF
directional spool to be held in any
position, resulting in infinitely variable,
reversible, pressure compensated
flow. This can be sustained indefinitely
XJUIPVUIBWJOHUPDPOUJOVFUPIPMEUIF
mechanical lever.

17.3

Please note:
17.3TIPVMEPOMZCFVTFEUPHFUIFS
with PVB basic modules with pressure
compensator.

PVMF,
Mechanical Float
Position Lock

PVMF, Mechanical Float Position Lock


This allows the float spool to be held in
the float position after release of the
mechanical handle.

PVMF
PAF
4UBOEBSEBTTFNCMZ

520L0344t3FW(&t%FD

PVMF
PBF
4UBOEBSEBTTFNCMZ

11

PVG 32 Proportional Valve


Technical Information
Function
PVBS,
Main Spools for Flow
Control (Standard)

8IFOVTJOHTUBOEBSEPXDPOUSPMTQPPMT UIFQVNQQSFTTVSFJTEFUFSNJOFECZUIF
highest load pressure. This is done either via the pressure adjustment spool in open
DFOUSF171 YFEEJTQMBDFNFOUQVNQT
PSWJBUIFQVNQSFHVMBUPS WBSJBCMFEJTQMBDFNFOU
pumps).
In this way the pump pressure will always correspond to the load pressure plus the
TUBOECZQSFTTVSFPGUIFQSFTTVSFBEKVTUNFOUTQPPMPSUIFQVNQSFHVMBUPS
This will normally give optimum and stable adjustment of the oil flow.

PVBS,
Main Spools
for Flow Control
(with Linear
Characteristic)

PVBS main spools with linear characteristic have less dead band than standard spools
and a completely proportional ratio between control signal and oil flow in the range
beyond the dead band. PVBS with linear characteristic must never be used together
XJUI17&.FMFDUSJDBMBDUVBUPST5IFJOUFSBDUJPOCFUXFFOUIFTNBMMEFBECBOEPGUIF
TQPPMTBOEUIFIZTUFSFTJTPGUIF17&.BDUVBUPSPGJOWPMWFTBSJTLPGCVJMEJOHVQB-4
pressure in neutral position.

PVBS,
Main Spools for Pressure
Control

In a few systems load sensing pump


QSFTTVSFNBZSFTVMUJOVOTUBCMFBEKVTU
ment of the oil flow and a tendency
towards system hunting. This may be the
case with working functions that have a
MBSHFNPNFOUPGJOFSUJBPSPWFSDFOUSF
valves. In such systems main spools for
pressure control can be advantageous.
The spools are designed in such a way
that the pump pressure is controlled by
the spool travel. The main spool must be
displaced until the pump pressure just
exceeds the load pressure before the working function is applied. If the main spool is
held in this position, the pump pressure will remain constant even if the load pressure
changes giving a stable system.
The use of pressure control spools, however, also means that
the oil flow is load dependent
the dead band is load dependent
the pump pressure can exceed the load pressure by more than is usual.
%VFUPUIFTFGBDUPSTJUJTSFDPNNFOEFEUIBUQSFTTVSFDPOUSPMTQPPMTBSFPOMZVTFEXIFO
it is known for certain that problems with stability will arise or already have arisen.

12

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Function
PVPX,
Electrical LS Unloading
Valve

PVPX is a solenoid LS unloading valve. PVPX is fitted into the pump side module
enabling a connection to be made between the LS and the tank lines. Thus the LS signal
can be
relieved to tank by means of an electric signal.
For a PVP pump side module in open centre version the relief to tank of the LS signal
means that the pressure in the system is reduced to the sum of the tank port pressure
plus the neutral flow pressure for the pump side module.
For a PVP pump side module in closed centre version the relief to tank of the LS signal
means that the pressure is reduced to the sum of the tank port pressure for the pump
TJEFNPEVMFQMVTUIFTUBOECZQSFTTVSFPGUIFQVNQ

520L0344t3FW(&t%FD

13

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
PVG 32
Valve Group

The technical data for PVG 32 and PVPX are typical measured results. For the hydraulic
TZTUFNBNJOFSBMCBTFEIZESBVMJDPJMXJUIBWJTDPTJUZPGNN2T<464>BOEB
UFNQFSBUVSFPG$<'>XBTVTFE

Max. pressure

Oil flow rated


4FFDIBSBDUFSJTUJDT
QBHF

Spool travel, standard


Spool travel,
float position, spool
%FBECBOE
flow control spools
Max. internal leakage
BUCBS<QTJ>BOE
NNT<464>
Oil temperature
JOMFUUFNQFSBUVSF

Port P continuous
Port P intermittent 5)
Port A/B continous
Port A/B intermittent5)
Port T, static/dynamic
Port P
Port A/B, with press.comp.

CBS

CBS
CBS
CBS
CBS
MNJO3) 4)
MNJO2)

<QTJ>
<QTJ>
<QTJ>
<QTJ>
<QTJ>
<64HBMNJO>3) 4)
<64HBMNJO>2)

Port A/B witout press.comp.


Proportional range
Float position
Standard
Linear characteristic

MNJO
7 mm
NN
NN
NN
NN

<64HBMNJO>
<JO>
JO>
<JO>
<JO>
<JO>

A/B T without shock valve

DN3/min

<JO3NJO>

A/B T with shock valve

25 cm3/min

<JO3NJO>

3FDPNNFOEFEUFNQFSBUVSF
Min. temperature
Max. temperature

 $
$
$
 $
NN2/s
4 mm2/s
NN2/s

< '>
<'>
<'>
< '>
<464>
<464>
<464>





MNJO

<64HBMNJO>

Ambient temperature
Operating range
Min. viscosity
Max. viscosity
Filtration
Max. contamination
4FFQBHF

*40

Oil consumtion in pilot oil pressure reduction valve

Oil viscosity


8JUI174*FOEQMBUF8JUI174FOEQMBUFNBYCBS<QTJ>

'PSMNJODPOUBDUUFDIOJDBM4BMFT0SHBOJ[BUJPOGPS4BVFS%BOGPTT

*OPQFODJSDVJUTZTUFNTXJUITIPSU1IPTFTUVCFT BUUFOUJPOTIPVMECFQBJEUPQSFTTVSFQFBLTBUPXT

MNJO<64HBMNJO>
4) For system with Mid inlet PVPVM, TFFQBHF

*OUFSNJUUFOUQSFTTVSFBUNBY DZDMFTPGGVMM17(MJGFUJNFDZDMFT XJUI174*FOEQMBUF
5IFNBYJNVNJOUFSNJUUFOUQSFTTVSFBUNBY DZDMFTTUSFTTFTUIFOFFEUPDPOSNBQQMJDBUJPOEVUZ
DZDMFCFGPSFQSPDFFEJOHXJUITQFDJDBUJPO'PSGVSUIFSJOGPSNBUJPODPOUBDUUFDIOJDBM4BMFT0SHBOJ[BUJPOGPS
4BVFS%BOGPTT

PVH,
Hydraulic Actuation

3FHVMBUJPOSBOHF
Max. pilot pressure
Max. pressure on port T

CBS
CBS
CBS


5IF173))SFNPUFDPOUSPMMFWFSTIPVMECFDPOOFDUFEEJSFDUUPUBOL

14

520L0344t3FW(&t%FD

<QTJ>
<QTJ>
<QTJ>

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
PVM,
Mechanical Actuation

3FHVMBUJPOSBOHF DPOUSPMMFWFS
3FHVMBUJPOSBOHF1SPQPSUJPOBMSBOHF
Float position





Neutral position
/rN
<MCGrJO>
/rN
17. 17&

<MCGrJO>
/rN
17. 17)
<MCGrJO>
Spool displacement from neutral position
Spool displacement from any other position
Spool displacement from neutral position
Spool displacement into float position
Spool displacement away from float position
17. 17.%

Operating force

17. 17.3
Operating force
17. 17.'
Control lever positions,
TFFQBHF

No

Max. spool travel


/rN
<MCGrJO>
/rN
<MCGrJO>
/rN
<MCGrJO>
/rN<MCGrJO>
/rN<MCGrJO>
/rN<MCGrJO>
/rN<MCGrJO>
/rN<MCGrJO>
26


17&XJUIPVUWPMUBHF

520L0344t3FW(&t%FD

15

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
PVE
Technical Data

The following technical data are from typical test results. For the hydraulic system a
NJOFSBMCBTFEIZESBVMJDPJMXJUIBWJTDPTJUZPGNNT<464>BOEBUFNQFSBUVSFPG
$<'>XFSFVTFE

PVEO and PVEM


PVEO and PVEM
4VQQMZWPMUBHF6%$

rated

7%$

7%$

range

7UP7

7UP7


max. ripple
"!7

Current consumption at rated voltage


4JHOBMWPMUBHF 17&.

"!7
Y6%$

neutral
"QPSU #QPSU

t6%$UPt6%$

4JHOBMDVSSFOUBUSBUFEWPMUBHF 17&.

N"

*OQVUJNQFEBODFJOSFMBUJPOUPt6%$

N"
,
8

Power consumption

Reaction time PVEO and PVEM


Supply voltage

%JTDPOOFDUFECZ
means
of neutral switch
%JTDPOOFDUFECZ
means
of neutral switch

Constant voltage

Constant voltage

PVEO
ON/OFF

PVEO-R
ON/OFF

PVEM
Prop. medium

max.







rated







min.







max.







rated







min.







max.



rated



min.



max.



rated



min.



rated



Function

3FBDUJPOUJNFGSPNOFVUSBM
position to max. spool travel

3FBDUJPOUJNFGSPNNBYTQPPM
travel to neutral position

3FBDUJPOUJNFGSPNOFVUSBM
position to max. spool position

3FBDUJPOUJNFGSPNNBYTQPPM
travel to neutral position

Hysteresis


)ZTUFSFTJTJTJOEJDBUFEBUSBUFEWPMUBHFBOEG)[GPSPOFDZDMF POFDZDMFOFVUSBMGVMM"GVMM#

OFVUSBM

16

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
PVEA, PVEH and PVES
PVEA, PVEH and PVES
4VQQMZWPMUBHF6%$

rated

7UP7

range

7UP7


max. ripple
Current consumption BUSBUFEWPMUBHF17&)17&4 17&"

 
"!7

Signal voltage

"QPSU #QPSU

t6%$UPt6%$
N"UPN"

Signal current at rated voltage


*OQVUJNQFEBODFJOSFMBUJPOUPt6%$

,
F

Input capacitor
17&)17&4 17&"

Power consumption

 
8
N"

Max. load
17&)17&4

 
"!7

Y6%$

neutral

N"

Active

3FBDUJPOUJNFBUGBVMU

NT 17&"NT

Passive

3FBDUJPOUJNFBUGBVMU

NT 17&"NT

Reaction time
PVEA
Supply voltage
%JTDPOOFDUFECZ
means
of neutral switch
%JTDPOOFDUFECZ
means
of neutral switch
Constant voltage

Constant voltage

Function

PVEH

Prop. fine Prop. high


s
s

PVES
Prop. super
s

max.
rated
min.













max.
rated
min.













max.
rated
position to max. spool travel
min.
max.
3FBDUJPOUJNFGSPNNBYTQPPM
rated
travel to neutral position
min.




























3FBDUJPOUJNFGSPNOFVUSBM
position to max. spool travel
3FBDUJPOUJNFGSPNNBYTQPPM
travel to neutral position
3FBDUJPOUJNFGSPNOFVUSBM

Hysteresis

rated


)ZTUFSFTJTJTJOEJDBUFEBUSBUFEWPMUBHFBOEG)[GPSPOFDZDMF POFDZDMFOFVUSBMGVMM"GVMM#OFVUSBM

Spool position

PVE
Technical Data
(Continued)

520L0344t3FW(&t%FD

17

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
Technical Data
(Continued)

Oil consumption PVEO and PVEM


Supply
voltage

Function

8JUIPVU
voltage

Pilot oil
PXQFS17&

8JUI
voltage

Pilot oil
flow per
17&

neutral
locked
one actuation
OFVUSBM max.)
continuous actuations
OFVUSBM max.)

PVEO
ON/OFF

PVEM
Prop. medium

MNJO
<64HBMNJO>
MNJO
<64HBMNJO>
M
<64HBM>
MNJO
<64HBMNJO>

MNJO
<64HBMNJO>
MNJO
<64HBMNJO>
M
<64HBM>
MNJO
<64HBMNJO>

Oil consumption PVEA, PVEH and PVES


Supply
voltage

Function

8JUIPVU
voltage

Pilot oil
PXQFS17&

neutral
locked

8JUI
voltage

Pilot oil flow


QFS17&

one actuation
OFVUSBM max.)
continuous
actuations

PVEA
Prop. fine

PVEH
Prop. high

PVES
Prop. super

MNJO
<64HBMNJO>
MNJO
<64HBMNJO>
M
<64HBM>
MNJO
<64HBMNJO>

MNJO
<64HBMNJO>
MNJO
<64HBMNJO>
M
<64HBM>
MNJO
<64HBMNJO>

MNJO
<64HBMNJO>
MNJO
<64HBMNJO>
M
<64HBM>
MNJO
<64HBMNJO>

Oil viscosity
Oil
viscosity

range
min.
max.

Oil temperature
NN2T<464>
4 mm2T<464>
NN2T<464>

Oil
UFNQFSBUVSF

3FDSBOHF
min.
max.

$<'>
$<'>
$<'>

/PUF.BYTUBSUVQWJTDPTJUZNN2/s

Filtering
Filtering in the
hydraulic system

18

Ambient temperature
Max. allowed degree of
DPOUBNJOBUJPO *40 
WFSTJPO


520L0344t3FW(&t%FD

Ambiant
temperature
SBOHF3FD

 $< '>

PVG 32 Proportional Valve


Technical Information
5FDIOJDBM%BUB
PVPX,
Electrical LS
Unloading Valve

Max. operating pressure


&ODMPTVSFUP*&$
.BYQSFTTVSFESPQBUBOPJMPXPGMNJO<64HBMNJO>
3FDPNNFOEFEUFNQFSBUVSF
0JMUFNQFSBUVSF JOMFU
temperature)

Min. temperature
Max. temperature

Max. coil surface temperature


Ambient temperature
Operating range
Oil viscosity

Min. viscosity
Max. viscosity

3FTQPOTFUJNFGPS-4QSFTTVSFSFMJFG
3BUFEWPMUBHF
Max. premissible deviation from rated supply voltage
BU$<'>DPJMUFNQFSBUVSF
Current consuption at
rated voltage
BU$<'>DPJMUFNQFSBUVSF
BU$<'>DPJMUFNQFSBUVSF
Power consumption
BU$<'>DPJMUFNQFSBUVSF

520L0344t3FW(&t%FD

CBS
<QTJ>
IP65
2 bar
<QTJ>
UP$
<UP'>
$
<'>
$
<'>
$
<'>
UP$
<UP'>
UPNN2/s
<UP464>
4 mm2/s
<464>
NN2/s
<464>
NT
7
24 V

"
"
"
"
8
8
8
8

19

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM"DUVBUJPO
Function

5IFQIJMPTPQIZPG4BVFS%BOGPTTFMFDUSPIZESBVMJDBDUVBUJPO UZQF17& JTJOUFHSBUJPO


of electronics, sensors and actuators into a single unit that interfaces directly to the
proportional valve body.

Pp



Closed loop control


All the proportional actuators feature an integrated feedback transducer that measures
spool movement in relation to the input signal, and by means of a solenoid valve
bridge, controls the direction, velocity and position of the main spool of the valve.
The integrated electronics compensate for flow forces on the spool, internal leakage,
changes in oil viscosity, pilot pressure, etc. This results in lower hysteresis and better
resolution. Furthermore the electronics enable built in safety like fault monitoring,
EJSFDUJPOBMJOEJDBUJPOBOE-&%MJHIUJOEJDBUJPO

Principle
*OQSJODJQMFUIFJOQVUTJHOBM TFUQPJOUTJHOBM
EFUFSNJOFTUIFMFWFMPGQJMPUQSFTTVSFXIJDI
NPWFTUIFNBJOTQPPM5IFQPTJUJPOPGUIFNBJOTQPPMJTTFOTFEJOUIF-7%5USBOTEVDFS
XIJDIHFOFSBUFTBOFMFDUSJDGFFECBDLTJHOBMSFHJTUFSFECZUIFFMFDUSPOJDT5IFWBSJBUJPO
CFUXFFOUIFTFUQPJOUTJHOBMBOEGFFECBDLTJHOBMBDUVBUFTUIFTPMFOPJEWBMWFT5IF
solenoid valves are actuated so that hydraulic pilot pressure drives the main spool into the
correct position.
Inductive transducer, LVDT
-JOFBS7BSJBCMF%JFSFOUJBM5SBOTGPSNFS
8IFOUIFNBJOTQPPMJTNPWFE BWPMUBHF
JTJOEVDFEQSPQPSUJPOBMUPUIFTQPPMQPTJUJPO5IFVTFPG-7%5HJWFTDPOUBDUGSFF
NPOJUPSJOHPGUIFNBJOTQPPMQPTJUJPO5IJTNFBOTBOFYUSBMPOHXPSLJOHMJGFBOEOP
MJNJUBUJPOBTSFHBSETUIFUZQFPGIZESBVMJDVJEVTFE*OBEEJUJPO -7%5HJWFTBQSFDJTF
position signal of high resolution.
Integrated pulse width modulation
1PTJUJPOJOHPGUIFNBJOTQPPMJO17&"17&)17&4JTCBTFEPOUIFQVMTFXJEUI
modulation principle. As soon as the main spool reaches the required position,
modulation stops and the spool is locked in position.
20

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM"DUVBUJPO
ON/Off Actuation

8JUIFMFDUSJDBM0/0''BDUVBUJPOUIFNBJO
spool is moved from neutral to maximum
stroke when power is connected.
PVEO, ON/OFF
.BJOGFBUVSFTPG17&0
Compact
 3PCVTUPQFSBUJPO
 8JUI)JSTDINBOOPS".1DPOOFDUPS
Low electrical power

Pp

V310113.A

PVEO-R, ON/OFF with hydraulic ramp


-JLF17&0 CVUGPSBQQMJDBUJPOTXIFSFMPOHFS
reaction time is needed.

Proportional
Actuation

8JUIFMFDUSJDBMQSPQPSUJPOBMBDUVBUJPOUIF
main spool position is adjusted so that it
corresponds to an electrical signal e.g.
from a remote control unit.

PVEM, proportional medium


17&.WFSTJPOTBSFSFDPNNFOEFEXIFSF
UIFSFJTBSFRVJSFNFOUGPSNFEJVNSFTPMV
tion proportional control and where
reaction and hysteresis are not critical.
.BJOGFBUVSFTPG17&.


0/0''NPEVMBUFE
Inductive transducer
Medium hysteresis
8JUI)JSTDINBOODPOOFDUPSPOMZ
Low electrical power
/PTFUVQQSPDFEVSF

Pp

C
V310112.A

PVEA, proportional fine


17&"WFSTJPOTBSFSFDPNNFOEFEXIFSF
among the requirements are fault
monitoring, low hysteresis, high resolution
but where the reaction time is not critical.
.BJOGFBUVSFTPG17&"
B

Inductive transducer
Integrated pulse width modulation
AMP connector only
"TPQUJPOXJUIEJSFDUJPOBMJOEJDBUPS %*

Fault monitoring with transistor output


for signal source.
Low electrical power
/PTFUVQQSPDFEVSF

520L0344t3FW(&t%FD

Pp

C
V310114.A

21

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM"DUVBUJPO
Proportional
Actuation
(Continued)

PVEH, proportional high


1FSGPSNBODFMJLF17&"CVUXJUIGBTUSFBDUJPOUJNF
.BJOGFBUVSFTPG17&)

Inductive transducer
Integrated pulse width modulation
Low hysteresis
Fast reaction time
Hirschmann or AMP connector
"TPQUJPOXJUIEJSFDUJPOBMJOEJDBUPS %*

Fault monitoring with transistor output for


signal source
Low electrical power
/PTFUVQQSPDFEVSF

PVES, proportional super


17&4WFSTJPOTBSFSFDPNNFOEFEGPS
control systems requiring very low
hysteresis to obtain a high resolution.
'PSPUIFSUFDIOJDBMEBUBTFF17&)
Hirschmann or AMP connector

22

520L0344t3FW(&t%FD

Pp

C
V310112.A

PVG 32 Proportional Valve


Technical Information
Fault Monitoring System
The Fault Monitoring
System

"GBVMUNPOJUPSJOHTZTUFNJTQSPWJEFEJOBMM17&" 17&)BOE17&4NPEVMFT5IFTZTUFNJT
available in two versions:
t5IFBDUJWFGBVMUNPOJUPSJOHUZQF XIJDIQSPWJEFTBXBSOJOHTJHOBM EFBDUJWBUFTUIF
solenoid valves and drives the spool in neutral.
t5IFQBTTJWFGBVMUNPOJUPSJOHUZQF XIJDIQSPWJEFTBXBSOJOHTJHOBMPOMZ
Both active and passive fault monitoring systems are triggered by three main events:
1. Input signal monitoring
The input signal voltage is continuously monitored. The permissible range is between
BOEPGUIFTVQQMZWPMUBHF0VUTJEFUIJTSBOHFUIFTFDUJPOXJMMTXJUDIJOUPBO
active error state.
2. Transducer supervision
 *GPOFPGUIFXJSFTUPUIF-7%5TFOTPSJTCSPLFOPSTIPSUDJSDVJUFE UIFTFDUJPOXJMM
switch into an active error state.
3. Supervision of the closed loop
 5IFBDUVBMQPTJUJPONVTUBMXBZTDPSSFTQPOEUPUIFEFNBOEFEQPTJUJPO JOQVUTJHOBM

*GUIFBDUVBMTQPPMQPTJUJPOJTGVSUIFSUIBOUIFEFNBOEFETQPPMQPTJUJPO  
17&"
UIFTZTUFNEFUFDUTBOFSSPSBOEXJMMTXJUDIJOUPBOBDUJWFFSSPSTUBUF
On the other hand, a situation where the actual position is closer to neutral than that
demanded will not cause an error state. This situation is considered in control.
 8IFOBOBDUJWFFSSPSTUBUFPDDVST UIFGBVMUNPOJUPSJOHMPHJDXJMMCFUSJHHFSFE
Active fault monitoring
 "EFMBZPGNT 17&"NT
CFGPSFBOZUIJOHIBQQFOT
The solenoid valve bridge will be disabled and all solenoid valves will be released.
An alarm signal is sent out through the appropriate pin connection.
 5IJTTUBUFJTNFNPSJ[FEBOEDPOUJOVFTVOUJMUIFTZTUFNJTBDUJWFMZSFTFU CZUVSOJOHP
the supply voltage).
Passive fault monitoring
 "EFMBZPGNT 17&"NT
CFGPSFBOZUIJOHIBQQFOT
The solenoid valve bridge will not be disabled but still control the main spool
position.
An alarm signal is sent out through the appropriate pin connection.
 5IJTTUBUFJTOPUNFNPSJ[FE8IFOUIFFSSPOFPVTTUBUFEJTBQQFBST UIFBMBSNTJHOBM
will turn to passive again. However, the signal will always be active for a minimum of
NTXIFOUSJHHFSFE
To prevent the electronics from going into an undefined state, a general supervision
of the power supply and the internal clock frequency is made. This function applies to
17&" 17&)BOE17&4BOEXJMMOPUBDUJWBUFGBVMUNPOJUPSJOH
1. High supply voltage
The solenoid valves are disabled when the supply voltage exceeds 36 V, and the main
spool will return/stay in neutral.
2. Low supply voltage:
 5IFTPMFOPJEWBMWFTBSFEJTBCMFEXIFOUIFTVQQMZWPMUBHFGBMMTCFMPX7 BOEUIF
main spool will return/stay in neutral.

520L0344t3FW(&t%FD

23

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM"DUVBUJPO
The Fault Monitoring
System (Continued)

3. Internal clock
The solenoid valves are disabled when the internal clock frequency fails, and the main
spool will return/stay in neutral.
WWARNING
Its up to the customer to decide on the required degree of safety for the system
TFF17&TFSJFTDBUBMPHVF%,.)1," QBHF


Note:
 %JFSFOUEFHSFFTPGTBGFUZBSFEFTDSJCFEPOpages 56 to 59.
 5IFGBVMUNPOJUPSJOHEPFTOPUXPSLJGUIFTVQQMZWPMUBHFUP17&"17&)17&4JTDVUPoGPSFYBNQMFCZB
neutral position switch TFFQBHF

 8IFOVTJOH17&"17&)17&4XJUIQBTTJWFGBVMUNPOJUPSJOHJUTVQUPUIFDVTUPNFSUPEFDJEFPOUIF

 SFRVJSFEEFHSFFPGTBGFUZGPSUIFTZTUFN see page 56).

Fault Monitoring
Specification

Type

Fault
monitoring

Delay
before error
out

Error mode

17&0
17&.

No fault
monitoring

<2V

Green
Flashing red

Active

No fault
Input signal faults
5SBOTEVDFS -7%5

Close loop fault


No fault
Input signal faults
5SBOTEVDFS -7%5

Close loop fault

Low

NT
17&"NT

High

6%$

Low

<2V

High

_6%$

17&"
17&)
17&4
Passive

NT
17&"NT


Measured between fault output pin and ground

24

520L0344t3FW(&t%FD

Error
Fault
output output
status on PVE 1)

LED light

Constant red
Green
Flashing red
Constant red

Memory
(reset
needed)

Yes

No

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM"DUVBUJPO
PVEA/PVEH/PVES,
Connection to Fault
Monitoring Output

Normal

Green
5SBOTJTUPSPVUQVUGVODUJPO

&YBNQMFPGDPOOFDUFEDPNQPOFOUT

"&YUFSOBMSFMBZ
#4PMFOPJEWBMWF FH1719

Fault
3FE
5SBOTJTUPSPVUQVUGVODUJPO

&YBNQMFPGDPOOFDUFEDPNQPOFOUT

"&YUFSOBMSFMBZ
#4PMFOPJEWBMWF FH1719

Via an external relay the pin pos. 3 can be connected to a solenoid valve which will
SFMJFWFUIF-4TJHOBMUPUBOL FH1719
Other connections possible:
a solenoid valve to relieve the pump oil flow
a signal lamp, an alarm horn
 QVNQDVUPVU FUD

520L0344t3FW(&t%FD

25

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVP, Pump Side Moduls
Symbol

Description
Open centre pump side module for
pumps with fixed displacement.

For purely machanically actuatet


valve groups

Closed centre pump side


module for pumps with vaiable
displacement.

For purely machanically actuatet


valve groups

Open centre pump side module for


pumps with fixed displacement.
8JUIQJMPUPJMTVQQMZGPSFMFDUSJDBMMZ
actuatet valves

Closed centre pump side module


pumps with variable displacement.
8JUIQJMPUPJMTVQQMZ
for electrically actuatet valves

Open centre pump side module for


pumps with fixed displacement.
8JUIQJMPUPJMTVQQMZGPSFMFDUSJDBMMZ
actuatet valves
Connection for electrical
LS unloading valve, PVPX
Closed centre pump side module
pumps with variable displacement
8JUIQJMPUPJMTVQQMZ
Connection for electrical
LS unloading valve, PVPX

Code number
P=G
T=G
P = 7/JO
5/JO
P
T=G
P
/JO
T

520L0344t3FW(&t%FD

#
#
#

P=G
T=G

#

= 7/JO
5/JO

#

P
=G
T

#

P
/JO
T

#

P=G
T=G
P = 7/JO
5/JO
P
=G
T
P
/JO
T

#

P=G
T=G
P = 7/JO
5/JO
P
=G
T
P
/JO
T
P=G
T=G
P = 7/JO
5/JO
P
=G
T
P
/JO
T
P=G
T=G
P = 7/JO
5/JO
P
=G
T
P
/JO
T

$POOFDUJPO 1(NNEFFQPS(NNEFFQ-4.(NNEFFQ5(NNEFFQ
P = 7/JOJOEFFQPS/JOJOEFFQ-4.JOJOEFFQ5/JOJOEFFQ

26

#

#
#
#
#
#
#
#
#
#
#
#
#
#
#
#

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVP, Pump side Moduls
Symbol

Description

Code number

Open centre pump side module for


pumps with fixed displacement.
For mechanical actuated valves.

P=G
T=G

#

Connection for LS unloading


valve, PVPX

Closed centre pump side


module for pumps with vaiable
displacement.
For mechanical actuated valves.
Connection for LS unloading
valve, PVPX

Open centre pump side module for


pumps with fixed displacement.
8JUIQJMPUPJMTVQQMZGPSFMFDUSJDBM
actuation and connection for pilot
oil pressure

P=G
T=G

P=G
T=G

#

#

1JO
5JO

#

P=G
T=G

#

1JO
5JO

#

P=G
T=G

#

1JO
5JO

#

Closed centre pump side module


pumps with variable displacement

P=G
T=G

#

8JUIQJMPUPJMTVQQMZGPSIZESBVMJD
actuation and connection for pilot
oil pressure

1JO
5JO

Closed centre pump side module


pumps with variable displacement.
8JUIQJMPUPJMTVQQMZGPSFMFDUSJDBM
actuation and connection for pilot
oil pressure

Open centre pump side module for


pumps with fixed displacement.
8JUIQJMPUPJMTVQQMZGPSIZESBVMJD
actuation and connection for pilot
oil pressure

#

Connection: P = G /2NNEFFQPS(3/4NNEFFQ-4.(/4NNEFFQ5(3/4NNEFFp.
P = 7/JOJOEFFQPS/JOJOEFFQ-4./2JOJOEFFQ5/JOJOEFFQ
520L0344t3FW(&t%FD

27

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVPV and PVPVM, Pump Side Modules
Symbol

Code
number

Description

PVPV
Closed center pump side module for
pumps with variable displacement.

1BOE5(

#

1BOE5 5/6/

#

1BOE5(

#

1BOE5 5/6/

#

1BOE5(

#

1BOE5 5/6/

#

1BOE5(

#

1BOE5 5/6/

#

8JUIQJMPUTVQQMZGPSFMFDUSJDBMBDUVBUJPO
.BYQVNQQSFTTVSFCBS<QTJ>
.BYQVNQPXMNJO
<64HBMNJO>

PVPV
Closed center pump side module for
pumps with vaiable displacement.
8JUIQJMPUTVQQMZGPSFMFDUSJDBMBDUVBUJPO
8JUIGBDJMJUZGPSTIPDLBOETVDUJPOWBMWF
PVLP 63
.BYQVNQQSFTTVSFCBS<QTJ>
.BYQVNQPXMNJO
<64HBMNJO>

PVPVM
Closed center pump side module for
pumps with variable displacement.
8JUIQJMPUTVQQMZGPSFMFDUSJDBMBDUVBUJPO
.BYQVNQQSFTTVSFCBS<QTJ>
.BYQVNQPXMNJO
<64HBMNJO>

PVPVM
Closed center pump side module for
pumps with variable displacement.
8JUIQJMPUTVQQMZGPSFMFDUSJDBMBDUVBUJPO
8JUIGBDJMJUZGPSTIPDLBOETVDUJPOWBMWF
PVLP 63
.BYQVNQQSFTTVSFCBS<QTJ>
.BYQVNQPXMNJO
<64HBMNJO>

."PH-4(<9/6/'>

28

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVB, Basic Modules Without Adjustable LSA/B Pressure Limiting Valves
Symbol

Code number
No facilities for
Facilities for
shock valves A/B shock valves A/B

Description

8JUIPVUMPBEESPQ
check valve and
pressure
compensator
Can be used where
load holding
valves prevent oil
from flowing back
through channel P.

(
NNEFFQ

#

#

JO
JOEFFQ

#

#

(
NNEFFQ

#

#

JO
JOEFFQ

#

#

(
NNEFFQ

#

JO
JOEFFQ

#

#

#

#

#

Load drop
check valve

Load drop check


valve.
LSA/B shuttle valve.
To be used with
float position
spools.

(
NNEFFQ
8JUIOPOEBNQFE
compensator valve
JO
JOEFFQ

520L0344t3FW(&t%FD

29

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVB, Basic Modules - Without Adjustable LSa/b Pressure Limiting Valves
Symbol

Description

Code number
No facilities for
Facilities for
shock valves A/B shock valves A/B
(
NNEFFQ

#

#

JO
JOEFFQ

8JUIEBNQFE
compensator valve

PVB, Basic Modules - With Adjustable LSa/b Pressure Limiting Valves


Symbol

8JUIOPOEBNQFE
compensator valve.
Adjustable LSA/B
pressure limiting
valves
&YUFSOBM-4
connection
port A/B.
Also used for
float position
spools.

%BNQFE
compensator
valve.
Adjustable LSA/B
pressure limiting
valves
&YUFSOBM-4
connection
port A/B

30

Code number
No facilities for
Facilities for
shock valves A/B shock valves A/B

Description

520L0344t3FW(&t%FD

(
NNEFFQ

#

#

JO
JOEFFQ

#

#

(
NNEFFQ

#

#

JO
JOEFFQ

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVM, Mechanical Actuation
Symbol

Code number
with stop screws w/o stop screws

Description



PVM, Standard, spring centered


Individual oil flow adjustment to ports A and B
8JUIPVUBDUVBUJPOMFWFSBOECBTF
Shaft for mounting of actuation lever

#
#

#
#

#

#

PVM, as standard, witout actuation lever.


8JUICBTFGPSNPVOUJOHPGBDUVBUJPOMFWFS




#
#

#
#

PVM, Standard, spring. Individual oil flow


BEKVTUNFOUUPQPSUT"BOE# "OPEJ[FE



#

PVMD, Cover for Mechanical Actuation


Symbol

Description

Code number

17.%
Cover for purely mechanically operated valve

#

PVH, Hydraulic Actuation


Symbol

Description
PVH,
Cover for hydraulic
remote control

Code number
( NNEFFQ

#

6/'JOEFFQ

#

PVMR, Friction Detent


Symbol

Description

Code number

17.3
Friction detent

#

Description

Code number

PVMF, Mechanical Float Position


Symbol

PVMF
Mechanical float position lock

520L0344t3FW(&t%FD

#

31

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
Code Numbers for
Use on PVG 32
157B....

PVE for PVG 32


PVEO, ON/OFF actuation
Code no. 157B....

17&0

Hirschmann
connector
12 V

24 V

12 V

24 V

12 V

24 V











4292

ON/OFF with ramp



4229





0/0''BOPEJ[FE

4266



not
available

4272

17&"%*

17&)

17&)%*
17&4

32

Hirschmann connector
12 V

24 V

Standard





'MPBU#





PVEA/PVEH/PVES, proportional actuation


Code no. 157B....
17&"

Deutsch
connector

ON/OFF

PVEM, proportional actuation


Code no. 157B....
17&.

AMP
connector

Hirschmann
connector
11 - 32 V

AMP
connector
11 - 32 V

Deutsch
connector
11 - 32 V

Standard, active fault monitoring

Not available

4734

4792

Standard, passive fault monitoring

Not available

4735, 4775*

Not available

Standard, active fault monitoring

Not available

4736

4796

Standard, passive fault monitoring

Not available

4737

Not available

Standard, active fault monitoring



 



Standard, passive fault monitoring

 

 



'MPBU# BDUJWFGBVMUNPOJUPSJOH

4332

Not available

4392

'MPBU" BDUJWFGBVMUNPOJUPSJOH

Not available



Not available

Standard, active fault monitoring

Not available





Standard, passive fault monitoring

Not available

Not available



IZTUFSFTJT BDUJWFGBVMUNPOJUPSJOH







IZTUFSFTJT QBTTJWFGBVMUNPOJUPSJOH



 

Not available

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVLA, Suction Valve (fitted in PVB)
Symbol

Description

Code number

Suction valve for


port A and/orB.

#

Plug for connecting the nonactive port to tank, when


using a single acting spool.

#

PVLP, Shock and Suction Valve (Fitted in PVB)


Symbol

Description

Shock and suction valve


for port A and/or B.
/PUBEKVTUBCMF

520L0344t3FW(&t%FD

Setting
bar
[psi]

Code number

32

63












265





725








2755

3335

3625





#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#





#

33

PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVS, End Plate
Symbol

Description

#

PVS, without active elements.


Max. intermittend LX
QSFTTVSFCBS<QTJ>

V310063.A

(NNEFFQ

#

JO JOEFFQ

#
#

PVSI, without active elements


8JUIPVUDPOOFDUJPOT

V310062.A

LX

#

PVS, without active elements.


No connections

V310062.A

LX

Code number

#

PVSI, without active elements


LX connections.
Max. intermittend LX
QSFTTVSFCBS<QTJ>

V310063.A

(NNEFFQ

#

JO JOEFFQ

C

PVAS, Assembly Kit


Code no,
157B...

10

11

12


























17# 1717.























8FJHIULH<MC>

<>

PVBs

<> <> <> <> <> <> <> <> <> <> <>


<>

PVAS, Assembly Kit for PVPVM


Description
Tie bolts and seals

1 PVB

2 PVB

3 PVB

4 PVB










GPSPOF17#PO17(* DPNCJOBUJPO

34

520L0344t3FW(&t%FD

Code number 157B....


5 PVB
6 PVB
7 PVB






8 PVB

9 PVB

10 PVB







PVG 32 Proportional Valve


Technical Information
Modules and Code Numbers
PVPX, Electrical LS Unloaded Valve
Symbol

Description

Code number

PVPX,
Normally open:
LS pressure relieved with no signal to PVPX

7

#

24 V

#

PVPX,
Normally closed:
LS pressure relieved with no signal to PVPX

7

#

24 V

#

PVPX,
Normally open with manual override:
LS pressure relieved with no signal to PVPX
.BOVBMPWFSSJEF%&TFMFDUT-4QVNQ

7

#

24 V

#

26 V

#
#

Plug

PVPC, Plug for External Pilot Oil Supply


Symbol

Description

Code number

( 
NNEFFQ

#

PVP,
Plug without check valve for open
or closed centre
JO
JOEFFQ

PVP,
Plug with check valve for
open centre

( 
NNEFFQ

JO
JOEFFQ

520L0344t3FW(&t%FD

#

#

35

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
General

The characteristics in this catalogue are typical measured results.


%VSJOHNFBTVSJOHBNJOFSBMCBTFEIZESBVMJDPJMXJUIBWJTDPTJUZPGNN2T<464>BU
BUFNQFSBUVSFPG$<'>XBTVTFE

PVP,
Pump Side Module

Pressure relief valve characteristic


in PVP
The pressure relief valve is set at an oil
PXPGMNJO<64HBMNJO>
Setting range:
UPCBS<UPQTJ>
XJUI174*FOEQMBUF
BOE
CBS<QTJ> XJUI174FOEQMBUF

Neutral flow pressure in PVP,


open centre

36

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

Oil flow characteristics


The oil flow for the individual spool depends on
t UZQFPGCBTJDNPEVMF
 XJUIXJUIPVUDPNQFOTBUJPO

t UZQFPGQVNQ
 YFEPSWBSJBCMFEJTQMBDFNFOU

Please note:
The letters AA, A, B, etc. denote spool types, see pages 62 to 69. The characteristic below
is shown for spool travel in both directions. All other characteristics are shown for spool
travel in one direction only.
Pressure-compensated PVB, open or closed centre PVP
The oil flow is dependent on the supplied pump oil flow. The characteristics are plotted
for a pump oil flow, QP, corresponding to the rated max. spool oil flow, QN.
*ODSFBTJOHUIFQVNQPJMPXUP  QN will give the same oil flow on the eighth as on
the first basic module.

6S = Signal voltage
6%$ = Supply voltage



 'JSTU17#BGUFS171
 &JHIUI17#BGUFS171

520L0344t3FW(&t%FD

37

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

Pressure compensated PVB, open or closed centre PVP


Linear characteristic
Please note:
For PVB basic modules without pressure compensator the top ends of the characteristics
NBYPJMPX
BSFEJFSFOUTPUIFZDPSSFTQPOEUPUIPTFPGUIFTUBOEBSEPXDPOUSPM
spools, see characteristics for PVB without pressure compensator.

6S

= Signal voltage

6%$ = Supply voltage


  'JSTU17#BGUFS171


38

 &JHIUI17#BGUFS171

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

PVB without pressure compensation, open centre PVP


Oil flow as a function of spool travel
The spool flow is dependent on the supplied oil flow, QP. The characteristics apply to
TVQQMZPJMPXPGMNJO<64HBMNJO>XJUIUIFBDUVBUJPOPGPOFCBTJDNPEVMF*G
several basic modules are activated at the same time, the characteristic depends on the
load pressure of the actuated basic modules.

520L0344t3FW(&t%FD

39

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

PVB without pressure compensation, open centre PVP


Oil flow QA/BBTBGVODUJPOPGTVQQMJFEQVNQPJMPX 2P) curves for fully displaced flow
control spools.
5IFQSFTTVSFESPQPGBOZPJMPXJOHCBDLUPUBOL 2P2A/B) is read on the curve for
neutral flow pressure in PVP, page 36.

40

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

PVB without pressure compensation, closed centre PVP


4FUQSFTTVSFEJFSFODFCFUXFFOQVNQQSFTTVSFBOE-4TJHOBMCBS<QTJ>

520L0344t3FW(&t%FD

41

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

PVB without pressure compensation, closed centre PVP


4FUQSFTTVSFEJFSFODFCFUXFFOQVNQQSFTTVSFBOE-4TJHOBMCBS<QTJ>

The oil flow is dependent on the pressure difference between the pump pressure and
the LS signal. Normally the pressure difference is set at the LS pump regulator.

42

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVB,
Basic Module

Pressure drop PVB at max. main


spool travel

Pressure drop PVB for open spool in


neutral position

Load-independent oil flow,


pressure-compensated PVB

Oil flow at LS pressure limiting,


pressure-, compensated PVB

520L0344t3FW(&t%FD

43

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
PVLP,
Shock and
Suction Valve

PVLP, shock valve


17-1JTTFUBUBOPJMPXPGMNJO
<64HBMNJO>
The shock valve PVLP is designed to
absorb shock effects. Consequently, it
should not be used as a pressure relief
valve.
If the working function requires the use
of a pressure relief valve, a PVB basic
NPEVMFXJUICVJMUJO-4A/B pressure
limiting valve should be used.

PVLA,
Suction Valve

PVLP/PVLA, suction valve

44

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
Pressure Control Spools,
Characteristics in
Extreme Positions

Size A:

Size B:
1: See example page 46

Size C:

Size D:
2: See example page 46

520L0344t3FW(&t%FD

45

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
Pressure Control Spools,
Characteristics in
Extreme Positions

Size E:

Pressure build-up
Max. oil flow can be reduced by about
XJUIPVUMJNJUBUJPOPGNBYJNVN
pressure by limiting the main spool
USBWFMGSPNNN<JO>UP
NN<JO>

Examples of How
To Use the Characteristics
for Pressure Control
Spools

Example of determining the oil flow


t (JWFO
  4QPPMUZQF#
  1SFTTVSFTFUUJOH1P:
CBS<QTJ>
  -PBEQSFTTVSF -4A/B: CBS<QTJ>
t 3FTVMU
  0JMPXMNJO<64HBMNJO> TFFpage 45 TJ[F#

Example of determining spool size
t (JWFO
  .BYPJMPX 2A/B:
MNJO<64HBMNJO>
  1SFTTVSFTFUUJOH1P
CBS<QTJ>
  -PBEQSFTTVSF 1LS 
CBS<QTJ>
A
t 3FTVMU
  %TQPPM TFFpage 45 TJ[F%

Please note:
Normally a smaller spool can be chosen with pressure control. It is our experience that
UIFTQPPMDBOCFPOFTJ[FTNBMMFSUIBOXJUIOPSNBMPXDPOUSPM

46

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
Characteristics for Float
Position Main Spools

Characteristics; oil flow, spool travel and voltage


5IFTQPPMTIBWF NNTQPPMUSBWFMJOEJSFDUJPO"BOENNUSBWFMJOEJSFDUJPO#
t NN<JO>TQPPMEJTQMBDFNFOUJOEJSFDUJPO"HJWFTNBYPJMPXUPQPSU"
t NN<JO>TQPPMEJTQMBDFNFOUJOEJSFDUJPO#HJWFTNBYPJMPXUPQPSU#
t NN<JO>TQPPMEJTQMBDFNFOUJOEJSFDUJPO#HJWFTDPNQMFUFMZPQFOPBUQPTJUJPO
A/B T.

Pressure drop A/B T at max. spool travel within the proportional range
(4.8 mm) [0.19 in]

4QPPMT%BOE&IBWFUIFTBNFPQFOJOHBSFBGPSGPSXBSEPXBOESFUVSOPX
4QPPM&DBOHJWFMNJO<64HBMNJO>QSFTTVSFDPNQFOTBUFEPJMPXEVFUPB
IJHIFSQSFTTVSFESPQBDSPTTTQPPM&5IJTPDDVSTEVSJOHTQPPMBDUVBUJPOPOMZ

520L0344t3FW(&t%FD

47

PVG 32 Proportional Valve


Technical Information
Technical Characteristics
Characteristics for Float
Position Main Spools

Pressure drop A/B T in float position

48

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
%JNFOTJPOT
Dimensions

22.5

23[0.91]

112.5[4.430]
115.5[4.457]

L
35[1.38]

48[1.89]

16.5[0.650]
12[0.47]

PVS=11.5[0.453]
PVSI=12[0.47]

34.5[1.358]
79.5[3.130]
95[3.74]

58.5[2.303]

B4
A4

A
B3
A3

B
1
2

38.5[1.516]

LS

38.5[1.516]

70.5[2.776]

141[5.55]

38.5[1.516]

L
L

B2

22[0.87]

A2

B1
A1

48[1.89]

24[0.94]
23[0.91]

37[1.46]
85.5[3.366]

23[0.91]

37[1.46]

69.5[2.736]
36[1.42]

21[1.118]
36.5[1.437]
95[3.74]

P
V310140.A

F : Shock and suction valve, PVLP


G : Pressure gauge connection; G /4 NNEFFQo</2 JO JOEFFQ>
H : Plug for external pilot oil supply, PVPC; G /2 NNEFFQo</2 JO JOEFFQ>
*  &MFDUSJDBM-4VOMPBEJOHWBMWF 1719
J : LS connection; G /4 NNEFFQo</2 JO JOEFFQ>
,  'JYJOHIPMFT.NJOo<5/JO JOEFFQ>
L : Port A and B; G /2 NNEFFQo<7/JO JOEFFQ>
M : LX connection: PVS; G / NNEFFQo<3/JO JOEFFQ>
PVSI; G /4 NN<JO>EFFQo</2 JO JOEFFQ>
N : LS pressure limiting valve
O : Tank connection; G 3/4 NNEFFQo</JO JOEFFQ>
P : Pressure relief valve
Q : Pump connection; G /2 NNEFFQPS(3/4 NNEFFQo<7/JO JOEFFQPS/JO JOEFFQ>
3  -4A and LSB connections; G /4 NN<JO>EFFQo</2 JO JOEFFQ>
41Q QJMPUQSFTTVSFDPOOFDUJPO(

PVB
-
L2

mm
<JO>
mm
JO>

10

11

12


<>

<>


<>

<>


<>

<>

226
<>

<>

274
<>
336
<>

322
<>

<>


<>
434
<>


<>

<>

466
<>
527
<>


<>
576
<>

562
<>
622
<>


<>

<>

520L0344t3FW(&t%FD

49

PVG 32 Proportional Valve


Technical Information
%JNFOTJPOT
Dimensions
(Continued)
X-X

72[2.83]

72[2.83]

PVPVM
PVLP
MA

Pilot
Supply
LS

13[0.51]

13[0.51]

L3
L1
L2

G1
[1 5/16 UNF]

PVS
PVS

26-30 Nm
<MCGtJO>

A1
B1

A1

A2

A1

24[0.94]

B1

B2

B1

86[3.39]

13[0.51]

24[0.94]

V310124.A

."PH-4(
8PSLQPSUEJNFTJPOT TFFQBHF

*O17(WBMWFHSPVQTUUFEXJUI1717VTFTUBOEBSE17"4 #
BOE

Stay Bolt Set, PVAS for


PVPVM
Qty.,basic Module

10

11

12

mm
L
<JO>
mm
L2
<JO>
mm
L3
<JO>


<>

<>

<>


<>

<<

<>


<>
262
<>

<>

262
<>

<>
227
<>


<>

<>
275
<>


<>

<>
323
<>


<>

<>

<>

454
<>

<>

<>


>

<>
467
<>


<>

\>

<>


<>
646
<>
563
<>

646
<>
694
<>

<>

50

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
%JNFOTJPOT
Dimensions
(Continued)

49.5[1.949]

P
V
H

7[0.28]

6.5[0.256]

7[0.28]

33[1.30]

P
V
M
D

110[4.33]
max.200.5[7.894]

0]
65[
6.5
~1

44 [
1.73
2]

A-A

85[3.35]

32[1.26]

P
V
M
R
/
F

85[3.35]
58.5[2.303]

45[1.77]

60[2.36]

17[0.67]

7[0.28]

129[5.08]
95[3.74]

13[0.51]

85.5[3.366]

B-B

PVEO

107[4.21]

110[4.33]
max.290.50[11.437]

60[2.36]

89.5[3.524]

117[4.61]
7[0.28]

139[5.472]

C-C

PVEM/PVEH/
PVES

107[4.21]

110[4.33]
max.290.50[11.437]

60[2.36]

V310141.A

F : G /4 NNEFFQ</2JO JOEFFQ>

520L0344t3FW(&t%FD

51

PVG 32 Proportional Valve


Technical Information
Notes
Notes

52

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Lever Positions
Control Lever Positions

Base with an angle of 22.5


Base with an angle of 37.5

19.5
19

.5

22.5

52

.5

82

142.5

2.5
11

.5

172.5

V310014.A

19.

.5

19

37.5

67

.5

.5

97

.5

127
157.5

187.5

V310018.A

520L0344t3FW(&t%FD

53

PVG 32 Proportional Valve


Technical Information
Hydraulic Systems
Manually Actuated
PVG 32 Fixed
Displacement Pump

$ 0WFSDFOUSFWBMWF

54

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Hydraulic Systems
Electrically Actuated PVG
32 Variable
Displacement Pump
(Electrical Actuator,
Shock Valves, etc.)

520L0344t3FW(&t%FD

55

PVG 32 Proportional Valve


Technical Information
&MFDUSJDBM4ZTUFNT
Electrical Connections,
General

5IFFMFDUSJDBMDPOOFDUJPOTUPSFNPUFDPOUSPMMFWFST 17&BDUVBUPSTBOEWPMUBHFTVQQMZBSF
made using an ordinary terminal strip.
The wiring diagrams below and on page 56 to 59 show only the basic outlines for the
electrical connection.
Voltage supply
'PSBNBJOUSBOTGPSNFSXJUITUBCJMJTFEPVUQVUWPMUBHF UIFSJQQMFNVTUOPUFYDFFEPG
rated voltage.

Electrical Connection
Example

Signal leads must not act as supply leads at the same time
VOMFTTUIFEJTUBODFCFUXFFOUIFBDUVBUPSNPEVMF17&BOE
UFSNJOBMCPBSEJTMFTTUIBON<ZBSET>BOEUIFMFBE
DSPTTTFDUJPOJTNJONN2<"8(>

US1 US2 P3A P3B P4A P4B

PVEH/A/S

3, 15, 16
1, 2, 14
10
22

8
7
6
19
20
21
Prop 1
Prop 2

Push/Dir.sw.3A
Push/Dir.sw.3B
Push/Dir.sw.4A
Push/Dir.sw.4B
U DC
Neut.sw.
U+
U- (GND)

Pin no.
Function

25 Pin SUB-D connector


XJUI.TDSFXT .*-%5-

F
2
3
1

PVEM

NC

2
3
1

PVEO

NC

2
3
1

&
F:

&NFSHFODZTUPQ
Signal output, fault monitoring

NC:

Not connected

- U +
DC
V310116.A

56

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
System Safety
Building in Safety

"MMNBLFTBOEBMMUZQFTPGEJSFDUJPOBMDPOUSPMWBMWFT JODMQSPQPSUJPOBMWBMWFT
DBOGBJM
Thus the necessary protection against the serious consequences of function failure
should always be built in.
For each application an assessment should be made of the consequences of pressure
failure and uncontrolled or blocked movements.
5PEFUFSNJOFUIFEFHSFFPGQSPUFDUJPOUIBUPVHIUUPCFCVJMUJOUPUIFTZTUFN 4BVFS
%BOGPTTNBLFTUIFGPMMPXJOHEJTUJODUJPOT
 .BYJNVNTBGFUZEFNBOET
2. High safety demands
3. Average safety demands
4. Limited safety demands.

WWarning

All makes and all types of directional control valves inclusive proportional valves can
fail and cause serious damage. It is therefore important to analyse all aspects of the
application.
Because the proportional valves are used in many different operation conditions and
applications, the manufacturer of the application is responsible for making the final
TFMFDUJPOPGUIFQSPEVDUTBOEBTTVSJOHUIBUBMMQFSGPSNBODF TBGFUZBOEXBSOJOHSFRVJSF
ments of the application are met.
The process of choosing the control system and safety level could e.g. be governed
CZ*40 4BGFUZSFMBUFEQBSUTPGDPOUSPMTZTUFN


520L0344t3FW(&t%FD

57

PVG 32 Proportional Valve


Technical Information
System Safety
1.
Maximum Safety
Demands

+
E
3

R
A

B
1
2

1/2

PVEA/H/S
M

V310186.A

8IFOUIFGBVMUNPOJUPSJOHTZTUFNJO17&)JTDPOOFDUFE UIFSFBDUJPOUPFMFDUSJDBMBOE
NFDIBOJDBMGBVMUT FHBTQPPMTFJ[VSF
JTGBTUBOEPQFSBUPSJOEFQFOEFOU4FFQBHF
fault monitoring.
A system can be protected against many electrical, hydraulic and mechanical faults by
building in components as shown in the diagram:
3 "MBSNMPHJD&)" PSSFMBZ
DPOOFDUFEUPUIFGBVMUNPOJUPSJOHTZTUFNJO17&)
& &MFDUSJDBMFNFSHFODZTUPQ
M: Solenoid valve
$ 1JMPUPQFSBUFEDIFDLWBMWF
5IFBMBSNMPHJD&)"DVUTPDVSSFOUUPUIFTPMFOPJEWBMWF .
XIFO17&)NPOJUPSJOH
registers a fault. The solenoid valve then leads the oil flow direct from pump to tank.
Thus all functions are without operating pressure, i.e. locked in position, because there is
OPQJMPUQSFTTVSFPOUIFQJMPUPQFSBUFEDIFDLWBMWF $

"DUVBUJPOPGUIFFNFSHFODZTXJUDI &
DVUTPDVSSFOUUPUIFQSPQPSUJPOBMWBMWFBOEUIF
TPMFOPJEWBMWF .
"DUVBUJPOJOUIJTDBTFJTNBOVBM CVUUIFSFTVMUJTUIFTBNFBTBCPWF
Stopping or disconnecting the pump drive motor is another safety measure, if the
system reaction time can be accepted.
Note:
The neutral position switch in the remote control units should not be used.
17&)XJUIGBVMUNPOJUPSJOHNVTUIBWFBDPOTUBOUWPMUBHFTVQQMZ

58

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
System Safety
2.
High Safety Demands

+
E

B
1
2

1/2

PVEM

V310187.A

5IFEJFSFODFCFUXFFOUIJTTBGFUZNFUIPEBOEUIFPOFQSFWJPVTMZEFTDSJCFE 
JTUIBU
IFSFUIFSFJTOPCVJMUJOBVUPNBUJDGBVMUNPOJUPSJOHBOEBOFVUSBMQPTJUJPOTXJUDI /
JT
connected.
The method still gives a high degree of protection, but requires operator intervention. It
is recommended that the neutral position switch be always connected to the electrical
system. This then automatically cuts off current to the proportional valve when the
remote control unit is in neutral position.

520L0344t3FW(&t%FD

59

PVG 32 Proportional Valve


Technical Information
System Safety
3.
Average Safety Demands

B
1

1/2

LS

PVEM

V310188.A

5IFEJFSFODFGSPNUIFQSFWJPVTNFUIPEJTUIBUUIF-4TJHOBMGSPNUIFQSPQPSUJPOBM
WBMWFJTMFEEJSFDUUPUBOLXIFOUIFFNFSHFODZTXJUDI &
JTBDUVBUFE5IJTDBOCF
BDIJFWFECZVTJOHUIF4BVFS%BOGPTT-4VOMPBEJOHWBMWF1719 JOUFHSBUFEJOUIFQVNQ
side module.
In a system with open centre PVP and a fixed displacement pump, the effect of the PVPX
JTBOBMNPTUQSFTTVSFMFTTTZTUFN CBS<QTJ>JFBMMGVODUJPOTSFRVJSJOHB
higher operating pressure will not operate, TFFQBHF.
The method can also be used in LS systems with a variable displacement pump and
closed centre version proportional valve.
5IFQSFTTVSFBGUFS-4SFMJFGUIFOEFQFOETPOUIFQVNQTUBOECZQSFTTVSF

60

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
System Safety
4.
Limited Safety Demands

+
E

B
1
2

1/2

PVEM

V310189.A

5IFTBGFUZTZTUFNDBODPOTJTUPGBOFNFSHFODZTXJUDI &
BOEBOFVUSBMQPTJUJPOTXJUDI
/
JGQSPUFDUJPOBHBJOTUFMFDUSJDBMGBJMVSFJTUIFPOMZSFRVJSFNFOU)FSF UIFSFJTOP
QSPUFDUJPOBHBJOTUIZESBVMJDBOENFDIBOJDBMGBVMUT TQPPMTFJ[VSFEJOBOFYUSFNF
position).

520L0344t3FW(&t%FD

61

PVG 32 Proportional Valve


Technical Information
Other Operating Conditions
Oil

The main duty of the oil in a hydraulic system is to transfer energy; but it must also
lubricate the moving parts in hydraulic components, protect them against corrosion, and
transport dirt particles and heat out of the system. It is therefore important to choose
the correct oil with the correct additives. This gives normal operation and long working
life.
Mineral oil
'PSTZTUFNTXJUI17(WBMWFT4BVFS%BOGPTTSFDPNNFOETUIFVTFPGNJOFSBMCBTFE
IZESBVMJDPJMDPOUBJOJOHBEEJUJWFT5ZQF)-1 %*/
PS). *40

Non-flammable fluids
1IPTQIBUFFTUFST )'%3VJET
DBOCFVTFEXJUIPVUTQFDJBMQSFDBVUJPOT)PXFWFS 
EZOBNJDTFBMTNVTUCFSFQMBDFEXJUI'1. 7JUPO
TFBMT
4PQMFBTFDPOUBDUUIF4BVFS%BOGPTT4BMFT0SHBOJ[BUJPOJGUIF17(WBMWFJTUPCFVTFE
XJUIQIPTQIBUFFTUFST
The following fluids should only be used according to agreement with the Sales
0SHBOJ[BUJPOGPS4BVFS%BOGPTT
t 8BUFSHMZDPMNJYUVSFT )'$VJET

t 8BUFSPJMFNVMTJPOT )'#VJET

t 0JMXBUFSFNVMTJPOT )'"&VJET

Biodegradable oils
PVG 32 valves can be used in systems with rapeseed oil. The use of rapeseed oil is
conditioned by
 DPNQMZJOHXJUIUIFEFNBOETPOWJTDPTJUZ XBUFSDPOUFOU UFNQFSBUVSFBOEMUFSJOH
FUD TFFDIBQUFSTCFMPXBOEUFDIOJDBMEBUBQBHF).
 BEBQUJOHUIFPQFSBUJOHDPOEJUJPOTUPUIFEJSFDUJPOTPGUIFPJMTVQQMJFS
#FGPSFVTJOHPUIFSCJPEFHSBEBCMFVJET QMFBTFDPOTVMUUIF4BVFS%BOGPTT0SHBOJ[BUJPO

Particle Content, Degree


of Contamination

Oil filtration must prevent particle content from exceeding an acceptable level, i.e. an
acceptable degree of contamination.
.BYJNVNDPOUBNJOBUJPOGPS17(JT TFF*40$BMJCSBUJPOJOBDDPSEBODF
XJUIUIF"$'5%NFUIPE

*OPVSFYQFSJFODFBEFHSFFPGDPOUBNJOBUJPOPGDBOCFNBJOUBJOFECZVTJOHB
filter fineness as described in the next section.

62

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Other Operating Conditions
Filtration

&FDUJWFMUSBUJPOJTUIFNPTUJNQPSUBOUQSFDPOEJUJPOJOFOTVSJOHUIBUBIZESBVMJDTZTUFN
performs reliably and has a long working life. Filter manufacturers issue instructions and
recommendations. It is advisable to follow them.
System filters
8IFSFEFNBOETPOTBGFUZBOESFMJBCJMJUZBSFWFSZIJHIBQSFTTVSFMUFSXJUICZQBTTBOE
JOEJDBUPSJTSFDPNNFOEFE&YQFSJFODFTIPXTUIBUBNOPNJOBMMUFS PSOFS
PSB
NBCTPMVUFMUFS PSOFS
JTTVJUBCMF
It is our experience that a return filter is adequate in a purely mechanically operated
valve system.
The fineness of a pressure filter must be selected as described by the filter manufacturer
TPUIBUBQBSUJDMFMFWFMPGJTOPUFYDFFEFE
The filter must be fitted with pressure gauge or dirt indicator to make it possible to check
the condition of the filter.
*OTZTUFNTXJUIEJFSFOUJBMDZMJOEFSTPSBDDVNVMBUPSTUIFSFUVSOMUFSNVTUCFTJ[FEUP
suit the max. return oil flow. Pressure filters must be fitted to suit max. pump oil flow.
Internal filters
The filters built into PVG 32 are not intended to filter the system but to protect important
components against large particles. Such particles can appear in the system as a result
PGQVNQEBNBHF IPTFGSBDUVSF VTFPGRVJDLDPVQMJOHT MUFSEBNBHF TUBSUJOHVQ 
contamination, etc.
5IFMUFSJOUIFFMFDUSJDBMBDUVBUPS17&QSPUFDUJOHUIFTPMFOPJEWBMWFTIBTBNFTIPG
N
#VSTUJOHQSFTTVSFESPQGPSJOUFSOBMMUFSTJTCBS<QTJ>

520L0344t3FW(&t%FD

63

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard PC Spools
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
E
D
C
100
65
40
[26.4] [17.2] [10.6]





To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]







ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
40
65
100
[10.6] [17.2] [26.4]





























































XBZ QPTJUJPO
Closed neutral position, PC A and B












XBZ QPTJUJPO
5ISPUUMFE PQFOOFVUSBM
position, PC A and B










XBZ QPTJUJPO
Closed neutral position, PC A










XBZ QPTJUJPO
Closed neutral position, PC B










XBZ QPTJUJPO
Throttled, open neutral position, PC A










XBZ QPTJUJPO
Throttled, open neutral position, PC B

64

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard PC Spools
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
E
D
C
100
65
40
[26.4] [17.2] [10.6]

7473

7472

To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]





ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

7452

7453



7542

7543

C
D
E
40
65
100
[10.6] [17.2] [26.4]

XBZ QPTJUJPO
Throttled, A T neutral position, PC B

7563

7562


XBZ QPTJUJPO
Throttled, B T neutral position , PC A

520L0344t3FW(&t%FD

65

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard PC Spools, Hydraulic Actuation
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
E
D
C
100
65
40
[26.4] [17.2] [10.6]

To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]

ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
40
65
100
[10.6] [17.2] [26.4]





















XBZ QPTJUJPO
Closed neutral position, PC A and B


XBZ QPTJUJPO
Closed neutral position, PC A


XBZ QPTJUJPO
Closed neutral position, PC B

66

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard FC Spools
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
F
E
D
C
130
100
65
40
[34.3] [26.4] [17.2] [10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]















To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]















































XBZ QPTJUJPO
Closed neutral position














XBZ QPTJUJPO
Throttled, open neutral position


XBZ QPTJUJPO
Closed neutral position, P A


XBZ QPTJUJPO
Closed neutral position, P B

520L0344t3FW(&t%FD

67

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard FC Spools
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
F
E
D
C
130
100
65
40
[34.3] [26.4] [17.2] [10.6]

7424

7423

7422

To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]



ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]



















XBZ QPTJUJPO
Throttled, A T in neutral position

7524

7523

7522




XBZ QPTJUJPO
Throttled, B T in neutral position

7624

7623

7622






XBZ QPTJUJPO
Closed neutral position
Float P B F

68

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
Standard FC Spools, Hydraulic Actuation
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
E
D
C
100
65
40
[26.4] [17.2] [10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]













To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
40
65
100
[10.6] [17.2] [26.4]

























XBZ QPTJUJPO 
closed neutral position












XBZ QPTJUJPO 
Throttled open neutral position

PVMR, FC Spools for Friction Detent


To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
E
D
C
100
65
40
[26.4] [17.2] [10.6]

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]

9724





9723

9722

To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
40
65
100
[10.6] [17.2] [26.4]





















XBZ QPTJUJPO 
closed neutral position

9734

9733

9732






XBZ QPTJUJPO 
Throttled open neutral position

520L0344t3FW(&t%FD

69

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
FC Spools for Mechanical Float Position PVMF
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
F
E
D
C
130
100
65
40
[34.3] [26.4] [17.2] [10.6]







To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]







ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]

XBZ QPTJUJPO
Closed neutral position
PAF

9624

623

9622




XBZ QPTJUJPO
Closed neutral position
Float P B F

70

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
FC Spools with Linear Flow Characteristic
To be used when PVB
is with LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]
F
E
D
C
130
100
65
40
[34.3] [26.4] [17.2] [10.6]

9774

9773

9772

To be used when PVB


is without LSA/B shuttle valve
Size
Press. compensated flow
l/min [US gal/min]

Code number
157B....

B
25
[6.6]

A
10
[2.6]

AA
5
[1.3]



ISO symbol

Symbol

AA
5
[1.3]

A
10
[2.6]

B
25
[6.6]

C
D
E
F
40
65
100
130
[10.6] [17.2] [26.4] [34.3]





9752

9753

9754





9762

9763

9764

9794



XBZ QPTJUJPO
Closed neutral position










XBZ QPTJUJPO
Throttled, open neutral position


XBZ QPTJUJPO
Throttled, A T in neutral position


XBZ QPTJUJPO
B T in neutral position

520L0344t3FW(&t%FD

71

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
PVB, basic valves

PVPV/M, pump side module closed center

Code no. 157B....

No facilities for shock


valves A and B
G 1/2

8JUIPVUDPNQFOTBUPSDIFDLWBMWF
8JUIDIFDLWBMWF
8JUIDIFDLWBMWFBOE-4A/B shuttle
valve
8JUIDPNQFOTBUPSWBMWF
8JUIEBNQFEDPNQFOTBUPSWBMWF
8JUIDPNQFOTBUPSWBMWF
LSA/B relief valve and
LSA/B shuttle valve
8JUIEBNQFEDPNQFOTBUPSWBMWF
LSA/B relief valve and
LSA/B shuttle valve
8FJHIU
LH<MC>

Facilities for shock


valves A and B

/8 - 14 UNF

G 1/2

















/8 - 14 UNF



6536











6236





6233

6633





<>

Code
no.
157B....

With pilot supply for PVE


and without
and with
PVLP 63
PVLP 63
G1 1 5/16 - 12UNF G1 1 5/16 - 12UNF

PVPV









PVPVM

5937







8FJHIU

LH<MC><>

<>
c

PVPC, plugs
Code no. 157B....

Weight
kg [lb]

G 1/2

1/2 in

&YUFSOBMQJMPUTVQQMZ

&YUFSOBMQJMPUTVQQMZJODMDIFDL

valve











- 20

1-10
13

PVM, mechanical actuation


Standard

#

Standard, with base,


without arm and button
Standard, without base,
arm and button
8FJHIU

#
#




















LH<MC>

11
a

12

<>

8JUIPVUTUPQTDSFXT "OPEJ[FE#

End plate, PVS, PVSI


Code no. 157B....
PVS, without connections
PVS, with LX connection
(<6/'>
PVSI, without connections
PVSI, with LX connections (<6/'>

BSP

SAE

Weight
kg
[lb]


















3.6
3.6

PVAS, assembly kit


Code no,
157B...

V310168.A

10

11

12

PVBs



























17# 1717.

























8FJHIULH<MC> <> <> <> <> <> <> <> <> <> <> <> <> <>

PVLP, shock/and anti-cavitation valves


$PEFOP#y                2265    
bar 32

63

           265    
Settings
<QTJ>  725         2755  3335  3625     
8FJHIU
LH<MC>

72

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Module Selection Chart
PVP, pump side module
Code no. 157B....

Open centre

Without pilot supply


for PVE
for PVE
with facilit.
for PVPX

for PVE

With pilot supply


for PVE and for PVE and
for PVH
facilit. for
pilot oil
and pilot
PVPX
pressure oil pressure
take-off
take-off

P = G /2, T = G 3/4
P = 7/JO 5/JO
P = G 3/4, T = G 3/4
1/JO 5/JO































P = G /2 , T = G 3/4,










<>




<>




<>




<>




<>




<>

P = 7/JO 5/JO
Closed centre
P = G 3/4, T = G 3/4,
1/JO 5/JO
8FJHIU
LH<MC>

PVPX, electrical LS pressure relief valves

Code no. 157B....

Normally closed

Normally open with


manual override

1-10
13

4236

4246

4256




Weight
kg
[lb]














 

Code No.

Weight

7
24 V
7
24 V
7
24 V
26 V

Normally open

Code
No.

Plug

PVE, electrical actuation

11

Code no. 157B....

Hir.
17&0 POP

12

c
17&03 POP
17&. QSPQNFEJVN
Standard

PVMD, PVH, PVMR, PVMF covers


Code no. 157B....
17.3 GSJDUEFUFOU

17.' NFDIPBUQPTJUJPO

Cover for PVM


Hydraulic actuation PVH
6/'
Hydraulic actuation PVH
(

Code No.

Weight
kg [lb]

























V310168.A

520L0344t3FW(&t%FD

AMP Deut.

kg [lb]

7  



<>

24 V  

4292

<>

7  

<>

24 V 4229 

<>

7 

<>

24 V 

<>

17&. QSPQNFEJVN 7 


o'MPBU#
24 V 

<>

<>

17&" BDUJWFGBVMUNPO
17&" QBTTJWFGBVMUNPO




4734
4735

4792


<>
<>

17&"%* BDUJWFGBVMUNPO
17&"%* QBTTJWFGBVMUNPO




4736
4737

4796


<>
<>

17&)BDUJWFGBVMUNPO
17&)QBTTJWFGBVMUNPO

 
 




<>
<>

17&)PBU# BDUGBVMU
17&)PBU" BDUGBVMU

4332




4392


<>
<>







<>
<>

 
 




<>
<>

17&)%*BDUJWFGBVMUNPO
17&)%*QBTTJWFGBVMUNPO
17&4 BDUJWFGBVMUNPO
17&4 QBTTJWFGBVMUNPO




PVLA, anti-cavitation valve


Code no. 157B....
Plug A or B
Valve A or B

Code No.



Weight
kg
[lb]





73

PVG 32 Proportional Valve


Technical Information
Order Specification
Order Specification

"OPSEFSGPSNGPS4BVFS%BOGPTT17(IZESBVMJDWBMWFJTTIPXOPOUIFOFYUQBHF5IF
GPSNDBOCFPCUBJOFEGSPNUIF4BVFS%BOGPTT4BMFT0SHBOJ[BUJPO
Both the module selection chart on the previous pages and the order form are divided
JOUPFMET     B C BOED
&BDINPEVMFIBTJUTPXOFME

 1VNQTJEFNPEVMF171

 1MVHGPSFYUFSOBMQJMPUPJMTVQQMZ171$

 &MFDUSJDBM-4VOMPBEJOHWBMWF1719
 #BTJDWBMWFT17#
 .BJOTQPPM17#4
B
.FDIBOJDBMBDUVBUPS17. PS17&XIFOPQUJPONPVOUFE

D
$PWFSGPSNFDIBOJDBMBDUVBUJPO17.%

$PWFSGPSIZESBVMJDBDUVBUJPO17)

&MFDUSJDBMBDUVBUPST17& PS17.XIFOPQUJPONPVOUFE

C
4IPDLBOETVDUJPOWBMWF17-1

4VDUJPOWBMWF17-"
 &OEQMBUF174
 "TTFNCMZLJU17"4
Please state
 $PEFOVNCFSTPGBMMNPEVMFTSFRVJSFE
 3FRVJSFETFUUJOH 1
GPSQVNQTJEFNPEVMF
 3FRVJSFETFUUJOHPG-4A/B pressure limiting valves, see pressure setting guidance
below.
Standard and option assembly
The PVG 32 valve group is assembled the way the module selection chart shows if the
DPEFOVNCFSGPS17.JTXSJUUFOJOFMEB BOEUIFDPEFOVNCFSGPS17.% 17&PS17)JO
field c.
The valve group is assembled so that the mechanical actuator is mounted on the
opposite end of the basic module, if the code number for PVM is written in field c of the
PSEFSGPSNBOEUIFDPEFOVNCFSTGPS17.% 17&PS17)JOFMEB
Reordering
5IFTQBDFBUUIFUPQSJHIUIBOEDPSOFSPGUIFGPSNJTGPS4BVFS%BOGPTTUPMMJO
5IFDPEFOVNCFSGPSUIFXIPMFPGUIFTQFDJFEWBMWFHSPVQ 17(/P
JTFOUFSFEIFSF
*OUIFFWFOUPGBSFQFBUPSEFSBMMZPVIBWFUPEPJTFOUFSUIFOVNCFS4BVFS%BOGPTTIBT
given on the initial confirmation of order.

74

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Order Specification
Order Specification

Pressure setting limits


The maximum setting pressure for the pressure limiting valves LSA or LSB depends on
the chosen pressure setting for shock valve PVLP. The maximum values recommended to
avoid interaction can be read in the following table.
The figures in the table have been calculated according to the following expressions:

17-1CBS-4A/B  PPVLP

17-1CBS1PVLP-4A/B CBS
Max. pressure setting of LSA and LSB valves relative to PVLP shock valve

Setting
pressure
for PVL
Max. setting
pressure
for LSA/B
Min. setting
pressure
for LSA/B

bar

32



63



<QTJ>



725



bar





64

<QTJ>





























265









       2755  3335  3625     






















235









            3625   

bar



<QTJ>

435

520L0344t3FW(&t%FD

75

PVG 32 Proportional Valve


Technical Information
Order Specification
PVG 32

Order Specification

Specification Sheet
Subsidiary/Dealer

PVG No.

Customer

Customer No.

Application

Revision No.

Function

A-Port

157B

p=

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

Remarks

Filled in by

bar

157B
LSA

10

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

bar

157B
LSA

11

157B

12

157B

B-Port

157B

bar

157B
157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

157B

13

157B

LSB

bar

157B

Date

PHYD-PVG32-3

Note:
4FQBSBUFTQFDJDBUJPOQBETXJUITIFFUTBSFBWBJMBCMFVOEFSUIFMJUFSBUVSFOP%,.)1;%
520L0515.

76

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Order Specification
PVG 32

Order Specification

SAE Specification Sheet


Subsidiary/Dealer

PVG No.

Customer

Customer No.

Application

Revision No.

Function

A-Port

157B

p=

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

157B

Remarks

Filled in by

psi

157B
LSA

10

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

psi

157B
LSA

11

157B

12

157B

B-Port

157B

psi

157B
157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

157B

13

157B

LSB

psi

157B

Date

PHYD-PVG32-3

520L0344t3FW(&t%FD

77

PVG 32 Proportional Valve


Technical Information
Notes
Notes

78

520L0344t3FW(&t%FD

PVG 32 Proportional Valve


Technical Information
Notes
Notes

520L0344t3FW(&t%FD

79

Products we offer:
Bent Axis Motors
Closed Circuit Axial Piston Pumps
and Motors
 %JTQMBZT
 &MFDUSPIZESBVMJD1PXFS4UFFSJOH
 &MFDUSPIZESBVMJDT
Hydraulic Power Steering

Sauer-Danfoss JTBHMPCBMNBOVGBDUVSFSBOETVQQMJFSPGIJHI
RVBMJUZIZESBVMJDBOEFMFDUSPOJDDPNQPOFOUT8FTQFDJBMJ[FJO
QSPWJEJOHTUBUFPGUIFBSUUFDIOPMPHZBOETPMVUJPOTUIBUFYDFMJO
UIFIBSTIPQFSBUJOHDPOEJUJPOTPGUIFNPCJMFPIJHIXBZNBSLFU
Building on our extensive applications expertise, we work closely
with our customers to ensure exceptional performance for a broad
SBOHFPGPIJHIXBZWFIJDMFT
8FIFMQ0&.TBSPVOEUIFXPSMETQFFEVQTZTUFNEFWFMPQNFOU 
reduce costs and bring vehicles to market faster.
4BVFS%BOGPTTo:PVS4USPOHFTU1BSUOFSJO.PCJMF)ZESBVMJDT

Integrated Systems
Joysticks and Control Handles

Go to www.sauer-danfoss.com for further product information.

Microcontrollers and Software


Open Circuit Axial Piston Pumps
Orbital Motors
 1-64 (6*%&
Proportional Valves
Sensors

8IFSFWFSPIJHIXBZWFIJDMFTBSFBUXPSL TPJT4BVFS%BOGPTT
8FPFSFYQFSUXPSMEXJEFTVQQPSUGPSPVSDVTUPNFST FOTVSJOH
the best possible solutions for outstanding performance. And with
an extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.

Steering
 5SBOTJU.JYFS%SJWFT
1MFBTFDPOUBDUUIF4BVFS%BOGPTTSFQSFTFOUBUJWFOFBSFTUZPV
Local address:

Members of the Sauer-Danfoss Group:


Comatrol
www.comatrol.com
Schwarzmller-Inverter
XXXTDIXBS[NVFMMFSJOWFSUFSDPN
Turolla
www.turollaocg.com
Hydro-Gear
XXXIZESPHFBSDPN
Sauer-Danfoss-Daikin
XXXTBVFSEBOGPTTEBJLJODPN

4BVFS%BOGPTT 64
$PNQBOZ
&BTUUI4USFFU
"NFT *" 64"
1IPOF 
'BY


4BVFS%BOGPTT"Q4
%,/PSECPSH %FONBSL
1IPOF 
'BY


4BVFS%BOGPTT(NC)$P0)(
1PTUGBDI %/FVNOTUFS
,SPLBNQ %/FVNOTUFS (FSNBOZ
1IPOF 
'BY


4BVFS%BOGPTT%BJLJO-5%