You are on page 1of 21

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool- Structural Analysis

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

Structural Analysis
Long wall

L3
L1

L2

Mvs
Mhs
L1`
Mhm
Mvm

Bending Moment
Serviceability Limit State
Mvm(KNm/m)

Mvs(KNm/m)

Mhm(KNm/m)

Mhs(KNm/m)

L1

20.3

38.2

5.7

7.9

L2

30.3

49.2

13.9

L3

25

53

5.1

10.4

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool- Structural Analysis

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

Ultimate Limit State


Mvm(KNm/m)

Mvs(KNm/m)

Mhm(KNm/m)

Mhs(KNm/m)

L1

28.5

53.5

7.5

11

L2

42.3

68.9

9.7

19.5

L3

35.3

75.3

7.2

14.6

Mvm(KNm/m)

Mvs(KNm/m)

Mhm(KNm/m)

Mhs(KNm/m)

22.5

39.8

5.6

8.2 /-6.6

Mvm(KNm/m)

Mvs(KNm/m)

Mhm(KNm/m)

Mhs(KNm/m)

31.6

55.7

7.9

11.5/ -9.3

Short Wall
Serviceability Limit State

Wall

Ultimate Limit State

Wall

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool- Structural Analysis

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

Bottom Slab

Serviceability Limit State


Mxm(KNm/m)

Mys(KNm/m)

Mxm(KNm/m)

Mxs(KNm/m)

S1

33.5

58.1

13.9

47.4

S2

28.8

50.1

19.3

41.5

Mxm(KNm/m)

Mys(KNm/m)

Mxm(KNm/m)

Mxs(KNm/m)

S1

46.9

80

19.6

66.4

S2

40.2

72

27

58

Ultimate Limit State

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool- Structural Analysis

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

Direct Tension

7.3m
1.5m
F

ULS
Maximum Water Pressure= 9.81*1.4*1.5= 20.6
Total water load= 0.5*20.6*1.5*7.3
Assuming total load is uniformly distributed,
Intensity of load= 0.5*20.6 = 10.3
RHB
table 63

R= 0.5*k*(1-0.25k)w(lx)2
= 0.5*1.42*(1-1.42/4)*10.3*1.62 =12.07
Direct tension by long wall= 12.07/1.6 = 7.54 kN/m
SLS
Maximum Water Pressure= 9.81*1.5= 14.72

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool- Structural Analysis

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Assuming total load is uniformly distributed,


Intensity of load= 0.5*14.72 = 7.36
R= 0.5*k*(1-0.25k)w(lx)2
= 0.5*1.42*(1-1.42/4)*7.36*1.62 =8.63
Direct tension by long wall= 8.63/1.6 = 5.4 kN/m

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool - Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

BS8007

Design of walls
Long wall Design

Cl 2.7.6

Thickness of the wall= 200mm


Cover= 40mm
Reinforcements to carry ULS bending moment

BS8110

Assume main bars to be 25mm and distribution bars to be 12mm in


diameter

Cl
3.4.4.4

d= 200-40-12-25/2 = 135.5 mm
Mvm=42.3 kNm/m
Mvs=75.3 kNm/m
M= 75.3 kNm/m
k=0.156 ( No redistribution)
k= M/(bd2fcu) = 75.3*10^6/(10^3*135.5^2*35)
=0.11< k (Hence no Compression reinforcement needed)
z= d(0.5+(0.25-k/0.9)^0.5) = 0.86d = 0.86*135.5 = 116.5mm
As= M/(0.87*fyz) =73.2*10^6/(0.87*460*116.5) = 1570mm2

No
compres
sion r/f
needed

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool - Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f to carry ULS direct tension


T=7.54 kN/m
As=7.54*10^3 / (0.87*460)
= 18.8mm2
R/f to carry Vertical Serviceability BM

M(SLS)= 52.2 kNm/m


M/(bd2)= 52.2*106/(103*135.52)=2.8
BS800T3.1
RHBT118

Allowable steel stress= fst= 130N/mm^2


From design chart,
r= 0.026

fcr= 11.5 N/mm2


r =As/bd

BS8007
-B2

As= 0.026*10^3*135.5 =3523mm2 (At Support)


M= 30.3 kNm/m at span
r= 0.016

As=2032.5mm2
Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr = 11.5
Hence Concrete stress is not near the ultimate

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool - Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

T3.1

Calculations

R/f to resist serviceability direct tension in mature concrete (SLS)


Allowable steel stress =130 N/mm2
Ast= T/fst = 5.4*10^3/130 = 42 mm2

R/f to resist shrinkage and thermal movement in immature concrete


2.6.2.3
A2

Minimum Steel ratio in each surface zone is given by


r

crit

= fct/fy = 0.0035

r = As/(bh)
Fig A.1

h= depth of surface zone


h=h/2(h<500mm)
As=0.0035*10^3*100= 350mm2/m

R/f to control crack spacing


A.3

R/f in controlling crack spacing is to be provided according to cl A3


BS8007
Wmax= smax. R. (T1+T2)
Lets take T1= 30c T2=10C and = 10**10^-6/C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool - Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

BS8007

Using 12mm bars and wmax= 0.2mm

2.2.3.3.

Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Long Wall Vertical R/F


R/f to carry ULS BM= 1570 mm2/m
R/f to carry out SLS BM = 3523mm2/m(@ support) ,2032mm2 (@span)
R/f to resist shrinkage and thermal movement = 400 mm2/m each layer

Long Wall Horizontal R/F


R/f to carry ULS tension = 19 mm2/m
R/f to carry SLS tension = 42 mm2/m
R/f to resist shrinkage = 400 mm2/m

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool - Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

BS
80072.6.2.3

Calculations

R/f provided

Max spacing = lesser of 300 and thickness (200mm) =200mm


Spacing<200mm

Long wall (Vertical)

Y25@200mm
Y25@130mm

Y25@130mm R/f provided= 3776mm2/m


Y25@200mm R/f provided= 2454mm2/m
Long wall (Horizontal)
Y12@ 200mm both sides = 565mm2/m

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

BS8110

Calculations

Checking for Shear

3.5.5

Ultimate shear stress from the SAP analysis long wall= 1020kN/m2
V=1.02 N/mm2
0.8(fcu)^0.5 = 0.8 (35)^0.5 = 4.73 N/mm2
V< 5 or 0.8(fcu)0.5
As= 3776 mm2
100As/bd = 100*3776/(1000*135.5) = 2.7
Vc= 1.2 N/mm2

v<vc
No shear r/f needed

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

BS8007

Design of walls
Short wall Design

Cl 2.7.6

Thickness of the wall= 200mm


Cover= 40mm
Reinforcements to carry ULS bending moment

BS8110
Cl
3.4.4.4

Assume main bars to be 25mm and distribution bars to be 12mm in


diameter
d= 200-40-12-25/2 = 135.5 mm
Mvm=31.6 kNm/m
Mvs=55.7 kNm/m
M= 55.7 kNm/m
k=0.156 ( No redistribution)
k= M/(bd2fcu) = 55.7*10^6/(10^3*135.5^2*35)
=0.086< k (Hence no Compression reinforcement needed)
z= d(0.5+(0.25-k/0.9)^0.5) = 0.89d = 0.89*135.5 = 121mm
As= M/(0.87*fyz) =55.7*10^6/(0.87*460*121) = 1150mm2

No
compres
sion R/f
needed

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f to carry Vertical Serviceability BM

BS8007
-T3.1
RHBT118

M(SLS)= 39.8 kNm/m


M/(bd2)= 39.8*106/(103*135.52)=2.1
Allowable steel stress= fst= 130N/mm^2
From design chart,
r= 0.02

BS8007
-B2

fcr= 10 N/mm2
r =As/bd
As= 0.02*10^3*135.5 =2710mm2
Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr = 10
Hence Concrete stress is not near the ultimate

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f to resist shrinkage and thermal movement in immature concrete


2.6.2.3

Minimum Steel ratio in each surface zone is given by

A2

crit

= fct/fy = 0.0035

r = As/(bh)

Fig A.1

h= depth of surface zone


h=h/2(h<500mm)
As=0.0035*10^3*100= 350mm2/m

R/f to control crack spacing

A.3

R/f in controlling crack spacing is to be provided according to cl A3


BS8007
Wmax= smax. R. (T1+T2)
Lets take T1= 30c T2=10C and = 10**10^-6/C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

BS8007

Using 12mm bars and wmax= 0.2mm

2.2.3.3.

Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Short Wall Vertical R/F


R/f to carry ULS BM= 1150 mm2/m
R/f to carry out SLS BM = 2710 mm2/m
R/f to resist shrinkage and thermal movement = 400 mm2/m each layer

Long Wall Horizontal R/F


R/f to resist shrinkage = 400 mm2/m

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

BS
80072.6.2.3

Calculations

R/f provided

Max spacing = lesser of 300 and thickness (200mm) =200mm


Spacing<200mm

Short wall (Vertical)

Y20@200mm
Y25@180mm

Y25@180mm R/f provided= 2727mm2/m


Y20@200mm R/f provided= 1570mm2/m
Long wall (Horizontal)
Y12@ 200mm both sides = 565mm2/m

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

Output

Bottom Slab

2
4

Bending Moments (Considering Both Slab 1 and 2)


Short way, edge M1= 80 kNm/m
Short way, Span M4= 46.9 kNm/m
Long way, edge M2= 66 kNm/m
Long way, Span M3=19.6 kNm/m
R/f to carry ULS bending Moment

M/bd^2

100As/bd

As

R/f

3.6

1475

Y20@200 (1570mm2)

2.1

0.55

811

Y20@200 (1570mm2)

0.82

1209

Y20@200 (1570mm2)

0.9

0.24

354

Y20@200 (1570mm2)

Max spacing = 3 *effective depth =3*147.5 =442>200mm

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f to carry Serviceability BM

BS8007
-T3.1
RHBT118

Along Short Span


M/(bd2)= 58*106/(103*147.52)=2.6
Allowable steel stress= fst= 130N/mm^2
From design chart,
r= 0.025

fcr= 11.5 N/mm2


r =As/bd
BS8007
-B2

As= 0.025*10^3*147.5 =3680mm2

Along Long Span


M/(bd2)= 47*106/(103*147.52)=2.1
Allowable steel stress= fst= 130N/mm^2
From design chart,
r= 0.02

fcr= 10 N/mm2
r =As/bd
As= 0.02*10^3*147.5 = 2950 mm2
Ultimate stress of concrete= 0.45 fcu = 0.45 *35 =15.8 N/mm2 > fcr =
11.5,10
Hence Concrete stress is not near the ultimate

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f to resist shrinkage and thermal movement in immature concrete

2.6.2.3

Minimum Steel ratio in each surface zone is given by


r

A2

Fig A.1

crit

= fct/fy = 0.0035

r = As/(bh)
h= depth of surface zone
h=h/2(h<500mm)
As=0.0035*10^3*100= 350mm2/m

R/f to control crack spacing

A.3

R/f in controlling crack spacing is to be provided according to cl A3


BS8007
Wmax= smax. R. (T1+T2)
Lets take T1= 30c T2=10C and = 10**10^-6/C
R= 0.5 for rigid end restraints
Wmax/smax = 0.5*10*10^-6(30+10) = 2*10^-4
Smax= fct/fb* (F/2r)
fct/fb = 0.67

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

BS8007

Using 12mm bars and wmax= 0.2mm

2.2.3.3.

Smax= 0.67*12/(2r)
Smax= Wmax/(2*10^-4)=1000mm
r = 0.67*6/1000 = 0.004 <rCrit = 0.0035
As = 0.004 *1000*100 = 400mm2/m
This steel has to be provided in both surface zones.

Slab R/F
R/f to carry ULS BM= 1475 mm2/m (At Support only)
R/f to carry out SLS BM = 3680mm2/m (Along short span) at Support
only (top)
R/f to carry out SLS BM = 2950 mm2/m (Along long span) at Support
only (top)
R/f to carry out span BM at other places (Typical) = 811 mm2/m (Bottom
span)
R/f to resist shrinkage and thermal movement = 400 mm2/m each layer

Output

Sheet No:

Project: Proposed 46 storied apartment building in Rajagiriya


Swimming Pool-Design

Project No: 001

Date:

Calculated by:

Checked
by:

CDPGroup-02

Ref

Calculations

R/f of the Bottom Slab

At Support along short span:Y25 @ 130mm = 3775mm2/m (Top)


At support along long span: Y25 @ 150mm = 3272 mm2/m (Top)
At span along short span: Y12 @130mm = 870mm2/m (Bottom)
At span along long span: Y12 @130 mm = 870mm2/m (Bottom)
Support Bottom long and short span : Y12 @150mm
At Span top short and long span way : Y12 @150mm

Output