You are on page 1of 15

FOOTING DESIGN:

Unfactored Load
Earth Quake
DL+LL
combination
825.00 kN
0.00 kN

Wind
Combination
0.00 kN

Axial load

Moment about X

Mx

0.00 kNm

0.00 kNm

0.00 kNm

Moment about Y

My

0.00 kNm

0.00 kNm

0.00 kNm

Horizontal force along X

Fx

0 00 kN
0.00

0 00 kN
0.00

0 00 kN
0.00

Horizontal force along Y

Fy

0.00 kN

0.00 kN

0.00 kN

150 kN/m2

Net Safe Bearing Capacity


Allowable increase in Safe Bearing Capacity for EQ

25 %

All
Allowable
bl increase
i
in
i Safe
S f Bearing
B i Capacity
C
it for
f Wind
Wi d

25 %
150 kN/m2

Gross Safe Bearing Capacity

18 kN/m3

Unit weight of soil


Surcharge load

0 kN/m2

Is Surcharge load eccentric (Y-Yes, N-No)

Enter Partial Surcharge load (According to quadrant)

0 kN

Total Surcharge load


Surcharge eccentricity
Surcharge moment

Column eccentricity

ey for Mx

0.6625 m

ex for My

0.6625 m

Mx

0.000 kNm

My

0.000 kNm

To be considered (Y-Yes, N-No)

Unsupported length of the column

lx

1500 mm

Unsupported length of the column

ly

1500 mm

Physical Eccentricity

ey for Mx

0 mm

ex for My

0 mm

ey for Mx

20.000 mm

ex for My

20.000 mm

Mx

24.800 kNm

My

24.800 kNm

Eccentricity
Minimum eccentricity moment

Self Weight of footing ={(2.65*2.65*0.3)+((0.3/3)*((2.65*2.65)+(((580)*(430))*10^-6)+SQRT((2.65*2.6


74.157 kN
Weight of soil above footing

=((2.65*2.65*1.5)-(74.157/25))*18

136.214 kN
CHECK FOR BASE PRESSURE
Area of footing
A
=2.65*2.65
Section Modulus
Zxx
=(2.65*(2.65^2))/6
Section Modulus
Zyy
=(2.65*(2.65^2))/6

7.023 m2
3.102 m3
3.102 m3

Forces at Base of footing:


Unfactored Load
Earth Quake
DL+LL
combination
1035.37 kN
210.37 kN
0.00 kNm
0.00 kNm
0.00 kNm
0.00 kNm

Axial load
Moment about X
Moment about Y
P1 = [P/A] + [Mx/Zx] + [My/Zy]
P2 = [P/A] + [Mx/Zx] - [My/Zy]
P3 = [P/A] - [Mx/Zx] + [My/Zy]
P4 = [P/A] - [Mx/Zx] - [My/Zy]

147.44
147.44
147.44
147.44
OK

DESIGN
Grade of concrete
Grade of steel
Clear cover

Wind
Combination
210.37 kN
0.00 kNm
0.00 kNm

29.96
29.96
29.96
29.96
OK

29.96
29.96
29.96
29.96
OK

20 N/mm2
415 N/mm2
50 mm

fck
fy

Design Forces
Axial load

1240.00 kN

Moment about X

24 80 kNm
24.80

Moment about Y

24.80 kNm

P1 = [P/A] + [Mx/Zx] + [My/Zy]

=(1240/7.0225)+(24.8/3.102)+(24.8/3.102)
192.57 kN/m2

P2 = [P/A] + [Mx/Zx] - [My/Zy]

=(1240/7.0225)+(24.8/3.102)-(24.8/3.102)
176 58 kN/m2
176.58

P3 = [P/A] - [Mx/Zx] + [My/Zy]

=(1240/7.0225)-(24.8/3.102)+(24.8/3.102)
176.58 kN/m2

P4 = [P/A] - [Mx/Zx] - [My/Zy]

=(1240/7.0225)-(24.8/3.102)-(24.8/3.102)
160.58 kN/m2
OK

BENDING MOMENT IN X DIRECTION


BENDING MOMENT =(177.722*1.135*(1.135/2))+(0.5*(184.571156054998-177.722)*1.135*(2/3)*1.
117.41 kNm/m
TOTAL BM

311.15 kNm

Is it a Trapezoidal section or Rectangular section


(T-Trapezoidal, R-Rectangular)

Effective width (For Trapezoidal, beq = b + ((1/8)*(B-b))


Effective depth

708 mm

=600-50-18

532 mm

Mulimit / b d

2.778

Effective depth required


R=Mu/bd2
Pt

397.88 OK
1 55
1.55

=((20/(2*415))*(1-(SQRT(1-((4.598*1.55)/20)))))*100

0.48 %

Minimum Ast

1508.4 mm2

Ast Required

1798.28 mm2

Diameter of bar used

12 mm

Centroid of bar

18 mm

Spacing Required

166.66 mm

Provided Spacing

125 mm
2397.66 mm2

Ast Provided
OK
CHECK FOR ONEWAY SHEAR

1356.61
174.78
232.00
2650

SHEAR FORCE

=(180.932*0.603)+(0.5*(184.571156054998-180.932)*0.603
110.20 kN/m

TOTAL SHEAR FORCE

292.03 kN
964942.7599 mm2

Area resisting Shear


Shear stress
Astt P
A
Provided
id d
Pt Provided

Shear resistance

0.30 N/mm2

2397.66
2397 66 mm2
0.25 %
9.35
0.36 N/mm2
OK

BENDING MOMENT IN Y DIRECTION


BENDING MOMENT =(177.269*1.21*(1.21/2))+(0.5*(184.571156054998-177.269)*1.21*(2/3)*1.21
133.33 kNm/m
TOTAL BM

353.33 kNm

Is it a Trapezoidal section or Rectangular section


(T-Trapezoidal, R-Rectangular)

Effective width (For Trapezoidal, beq = b + ((1/8)*(B-b))


Effective depth
Mulimit / b d2

839 mm

=600-50-6

544 mm
2.778

Effective depth required


R=Mu/bd2
Pt

389.41 OK
1 42
1.42

=((20/(2*415))*(1-(SQRT(1-((4.598*1.42)/20)))))*100

0.43 %

Minimum Ast

1535.4 mm2

Ast Required

1976.77 mm2

Diameter of bar used

12 mm

Centroid of bar

6 mm

Spacing Required

151.61 mm

Provided Spacing

125 mm
2397.66 mm2

Ast Provided
OK
CHECK FOR ONEWAY SHEAR

1408.00
180.00
244.00
2650

SHEAR FORCE

=(180.552*0.666)+(0.5*(184.571156054998-180.552)*0.666
121.59 kN/m

TOTAL SHEAR FORCE

322.20 kN
1011820 mm2

Area resisting Shear


Shear stress
Astt P
A
Provided
id d
Pt Provided

Shear resistance

0.32 N/mm2

2397.66
2397 66 mm2
0.24 %
9.80
0.35 N/mm2
OK

CHECK FOR TWOWAY SHEAR


176.58 kN/m2
1115.51 kN

Base pressure
Shear force
ks
c

1
1.12

Shear Resistance

1827.55 kN
OK

TRANSFER OF FORCE AT COLUMN BASE


Footing Area A1

7.0225 m2

Column Area A2

0.0874 m2

For footing Sqrt (A1/A2)

For Column Sqrt (A1/A2)

fbr max - col


Column grade
Limiting bearing resistance
Factored compressive force
Force to be transferred by reinforcement
CHECK

9 N/mm2
20 N/mm2
786600 N
1240000 N
453400
PROVIDE REINFORCEMENT,
REINFORCEMENT DOW

DIMENSION

Factored Load

OK

1240.00 kN

My

0.00 kNm
0.00 kNm

380 mm

0 00 kN
0.00
0.00 kN

2.65 m

230 mm
100 mm

8.69

8.69

12

6.00

8.75

100 mm
2.65 m

PLAN OF FOOTING
kN
kN

G.L.

11.8

0.30 m

11.8

0.30 m

1.50 m

23.62

2.65 m
CROSS SECTION OF FOOTING

65)*(((580)*(430))*10^-6))))}*25

176.575
176.575

192.567

P2

P1

P4

P3

2.65 m

160.584

2.65 m
160.584

BASE SOIL PRESSURE DISTRIBUTION DIAGRAM

176.575

192.567
176.575
P2

135

185.718
P1

1.357

CRITICAL SE
A
12 mm Dia.

A
CRITICAL SE

P4

P3
2.65

160.584

169.726

Critical section for BM is at a distance =

0.190 m

176.575

from the centre of footing

OK

0.290
0.190

1.035
0.900

1.025
CRITICAL SEC. FOR B.M
CRITICAL SEC. FOR SHEAR

0.60
0.552 0.475
0.190

Average Soil
pressure distribution

16.16deg

1.135
SECTION - AA

177.722

180.932
0.532

0.603
CRITICAL SECTION FOR SHEAR LIES

12 mm Dia. B

176.575

P2

P1

169.273
2.65

160 584
160.584

P4

P3
2.65

Critical section for BM is at a distance =

0.115 m

from the centre of footing

OK

0.215
0.115

1.110
0.900

1.020
CRITICAL SEC. FOR B.M
CRITICAL SEC. FOR SHEAR

0.60
0.554 0.480
0.115

Average Soil
pressure distribution

15.12deg

1.210
SECTION - AA

177.269

180.552
0.544

0.666
CRITICAL SECTION FOR SHEAR LIES
912

900.76

Area
551.884

553.514

2.65 m

2 65 m
2.65

WELS OR MECHANICAL CONNECTORS

SLIDING
Sliding Force
Resisting Force
Factor of safety

X
Mx

0.00 kN

0.00 kN

0.00 kN

288 75
288.75

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

#DIV/0!

192.567

176.575

EC. FOR SF

1.200
R

0 300
0.300

184.571

S INSIDE THE FOOTING

192.567

185.265

176 575
176.575

1.200
R

0 300
0.300

184.571

S INSIDE THE FOOTING

442779.1641 mm2

551.884

786.06
0.000

Area

374526 3 mm2
374526.3

You might also like