You are on page 1of 16

Room

lx= 4.04 m

ly= 4.23 m

ly/lx= 4.23/4.04 = 0.955 <2


Hence design two way slab
d = lx/25 = 4040/25 = 161.6 mm 160 mm
D=d+25= 160+25= 185 mm
Effective span:
lex = 4.04+0.16 = 4.2 m
ley = 4.23+0.16 = 4.27 m
center to center distance = 4.27 m
Loads:
Self weight = 0.18525= 4.625 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 7.625 KN/m2

= 11.43 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.037

-ve y= 0.037

+ve x= 0.028

-ve y= 0.028

M(-ve)= xWulex2= 7.46 KN-m


M(+ve)= xWulex2= 5.65 KN-m
M(-ve)= yWulex2= 7.46 KN-m
M(+ve)= yWulex2= 5.65 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 7.46 KN-m

d= 51.9 mm < 160 mm


it is sufficient to resist the ultimate design moment.

Ast min= 0.12%bd=0.00121000185 = 222 mm2


Reinforcement Details:
At Supports along short span direction:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 132.07 mm2

Mu= 7.46 KN-m


Actual Ast= 222 mm2

Assume bar diameter of 10 mm


Ast= 314 mm2
At Supports along long span direction:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 99 mm2

Mu= 5.65 KN-m


Actual A st= 222mm2

Assume bar of diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 353.78 mm
The spacing should not be greater than 300 mm
Hence S= 300 mm
Torsion steel:
Ast = 0.75(Ast main)
= 166.5mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 40
Pt = 100 Ast/bd
= (L/D)prov = 30
Hence the deflection control is verified.

Room

lx= 3.62 m

ly= 7.12 m

ly/lx= 7.12/3.62 = 1.96 <2


Hence design two way slab
d=lx/25 = 3620/25 = 145 mm
D=d+25= 145+25= 170 mm
Effective span:
lex = 3.62+0.145 = 3.765 m
ley = 7.12+0.145 = 7.265 m
center to center distance = 3.62+0.23 = 3.85 m
hence Lex = 3.765 m
LOADS:
Self weight = 0.17025 = 4.25 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 7.25 KN/m2

= 10.875 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.083

-ve y= 0.037

+ve x= 0.064

-ve y= 0.028

M(-ve)= xWulex2= 12.79 KN-m


M(+ve)= xWulex2= 9.86 KN-m
M(-ve)= yWulex2= 5.7 KN-m
M(+ve)= yWulex2= 4.3 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 12.79 KN-m

d= 68 mm < 145 mm
It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000170 = 204 mm2
Reinforcement Details:
At Supports along short span direction:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Mu= 12.79 KN-m

Ast= 253.58 mm2


Assume bar diameter of 10 mm
Ast= 314 mm2
At Supports along long span direction:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast=199 mm2

Mu= 9.86 KN-m


Actual A st= 204 mm2

Assume bar of diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 309 mm
The spacing should not be greater than 300 mm
Hence S= 300 mm
Torsion steel:
Ast = 0.75(Ast main)
= 190 mm2
Provide 6mm diameter bars @ 150 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 40
Pt = 100 Ast/bd
= (L/D)prov = 30
Hence the deflection control is verified.

Room

lx = 3.24 m

ly = 4.04 m

ly/lx = 4.04/3.24 = 1.24 <2


Hence design two way slab
d=lx/25 = 3240/25 = 118 120 mm
D=d+25 = 120+25= 145 mm
Effective span:
lex = 3.6224+0.120 = 3.36 m
center to center distance = 3.24+0.23 = 3.47 m
hence Lex = 3.36 m
LOADS:
Self weight = 0.14525 = 3.625 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 6.625 KN/m2

= 9.94 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.049

-ve y= 0.037

+ve x= 0.037

-ve y= 0.028

M(-ve)= xWulex2= 5.5 KN-m


M(+ve)= xWulex2= 4.15 KN-m
M(-ve)= yWulex2= 4.15 KN-m
M(+ve)= yWulex2= 3.14 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 5.5 KN-m

d= 44.6 mm < 120 mm


It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000145 = 174 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 130 mm2

Mu= 5.5 KN-m

but, actual Ast = 174 mm2

Assume bar diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 451 mm
The spacing should not be greater than 300 mm
Hence S= 300 mm
Torsion steel:
Ast = 0.75(Ast main)
= 130.5 mm2
Provide 6mm diameter bars @ 220 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 28
Pt = 100 Ast/bd
= (L/D)prov = 23
Hence the deflection control is verified.

Room

lx= 4.04 m

ly= 1.83 m

ly/lx= 4.04/1.83 = 2.2 > 2


Hence design one way slab
d=lx/25 = 4040/25 = 161.6 160 mm
D=d+25= 160+25 = 185 mm

Effective span:
Effective span = clear span + effective depth
= 4.04 + 0.16
= 4.2 m
Effective span is = 4.04 + 0.23 = 4.27 m
Hence, effective span is = 4.2 m
LOADS:
Self weight = 0.18525 = 4.625 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2
= 7.375 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 11.06 KN/m2

Ultimate moments & shear force:


Mu = wl2/8 = 24.4 KN-m
Vu = wl/2 = 23.22 KN
Limiting moment of resistance:
Mu(lim) = 0.138fckbd2 = 70.65 KN-m
Mu < Mu(lim)
Hence slab can resist the ultimate moments
Tension reinforcements:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Mu = 24.4 KN-m
Ast = 449.6 mm2
Provide 10 mm dia bars
Spacing:
S= dia of single bar/ Ast(provided)= 200 mm
Room

lx= 3.62 m

ly= 5.14 m

ly/lx= 5.15/3.62 = 1.422 <2

Hence design two way slab


d = lx/25 = 3620/25 = 145 mm
D=d+25= 145+25= 170 mm
Effective span:
lex = 3.62+0.145 = 3.765 m
ley = 3.62 +0.23 = 3.85 m
center to center distance = 3.765 m
Loads:
Self weight = 0.1725= 4.25 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2
= 7. 25 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 10.875 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.056

-ve y= 0.037

+ve x= 0.0425

-ve y= 0.028

M(-ve)= xWulex2= 8.63 KN-m


M(+ve)= xWulex2= 6.55 KN-m
M(-ve)= yWulex2= 5.7 KN-m
M(+ve)= yWulex2= 4.3 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 8.63 KN-m

d= 56 mm < 145 mm
It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000170= 204 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 169 mm2


Assume bar diameter of 10 mm

Mu= 8.63 KN-m


Actual Ast= 204 mm2

Ast= 314 mm2


At Supports along long span direction:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 99 mm2

Mu= 5.65 KN-m


Actual A st= 222mm2

Assume bar of diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 250 mm
Hence S= 250 mm
Torsion steel:
Ast = 0.75(Ast main)
= 236.5 mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 36
Pt = 100 Ast/bd
= (L/D)prov = 24.13
Hence the deflection control is verified.

Room

lx= 3.62 m

ly= 4.15 m

ly/lx= 4.15/3.62 = 1.146 <2


Hence design two way slab
d = lx/25 = 3620/25 = 150 mm
D=d+25= 145+25= 175 mm
Effective span:
lex = 3.62+0.150 = 3.77 m
ley = 3.62 +0.23 = 3.85 m

center to center distance = 3.77 m


Loads:
Self weight = 0.17525= 4.375 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2
= 7. 375 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 11.0625 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.04768

-ve y= 0.037

+ve x= 0.03576

-ve y= 0.028

M(-ve)= xWulex2= 6.912 KN-m


M(+ve)= xWulex2= 5.18 KN-m
M(-ve)= yWulex2= 5.36 KN-m
M(+ve)= yWulex2= 4.05 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 6.912 KN-m

d= 45 mm < 150 mm
It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000175= 210 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 130 mm2

Mu= 6.912 KN-m


Actual Ast= 210 mm2

Assume bar diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 300 mm
Hence S= 300 mm
Torsion steel:
Ast = 0.75(Ast main)

= 236.5 mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 36
Pt = 100 Ast/bd
= (L/D)prov = 24.13
Hence the deflection control is verified.

Room

lx= 4.04 m

ly= 4.50 m

ly/lx= 4.04/4.50 = 1.113 <2


Hence design two way slab
d = lx/25 = 3040/25 = 175 mm
D=d+25= 145+25= 200 mm
Effective span:
lex = 4.04+0.175 = 4.215 m
ley = 4.04 +0.23 = 4.274 m
center to center distance = 4.215 m
Loads:
Self weight = 0.225= 5 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 8 KN/m2

= 12 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.044

-ve y= 0.037

+ve x= 0.033

-ve y= 0.028

M(-ve)= xWulex2= 8.617 KN-m

M(+ve)= xWulex2= 6.463 KN-m


M(-ve)= yWulex2= 7.246 KN-m
M(+ve)= yWulex2= 5.484 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 8.617 KN-m

d= 55.87 mm < 175 mm


It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000200= 240 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 138.6 mm2

Mu= 8.617 KN-m


Actual Ast= 240 mm2

Assume bar diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 250 mm
Hence S= 250 mm
Torsion steel:
Ast = 0.75(Ast main)
= 236.5 mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 40
Pt = 100 Ast/bd
= (L/D)prov = 23.08
Hence the deflection control is verified.

Room

lx= 3.62 m

ly= 3.73 m

ly/lx= 3.62/3.73 = 1.02 <2


Hence design two way slab
d = lx/25 = 3620/25 = 145 mm
D=d+25= 145+25= 170 mm
Effective span:
lex = 3.62+0.17 = 3.79 m
ley = 3.62 +0.23 = 3.85 m
center to center distance = 3.79 m
Loads:
Self weight = 0.1725=4.25 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2
= 7.25 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 10.875 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.037

-ve y= 0.037

+ve x= 0.028

-ve y= 0.028

M(-ve)= xWulex2= 5.799 KN-m


M(+ve)= xWulex2= 4.373 KN-m
M(-ve)= yWulex2= 5,799 KN-m
M(+ve)= yWulex2= 4.373 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 5.799 KN-m

d= 45.75 mm < 145 mm


It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000200= 204 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Mu= 5.799 KN-m

Ast= 122 mm2

Actual Ast= 204 mm2

Assume bar diameter of 10 mm


Ast= 314 mm2
Spacing:
S= dia of single bar/ Ast(provided)= 250 mm
Hence S= 250 mm
Torsion steel:
Ast = 0.75(Ast main)
= 236.5 mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 40
Pt = 100 Ast/bd
= (L/D)prov = 26.138
Hence the deflection control is verified.

Room

lx= 3.09 m

ly= 4.04 m

ly/lx= 4.04/3.09 = 1.3 <2


Hence design two way slab
d = lx/25 = 3090/25 = 130 mm
D=d+25= 130+25= 155 mm
Effective span:
lex = 3..09+0.155 = 3.245 m
ley = 3.09 +0.23 = 3.32 m
center to center distance = 3.245 m
Loads:
Self weight = 0.15525=4.25 KN/m2
Live load

= 2 KN/m2

Floor finish

= 1 KN/m2
= 6.875 KN/m2

W(total)=sum of above
Wult=1.5 W(total)

= 10.3125 KN/m2

Ultimate Design Moments and Shear Forces:


B.M coefficients For Rectangular Panels:
-ve x= 0.051

-ve y= 0.037

+ve x= 0.039

-ve y= 0.028

M(-ve)= xWulex2= 5.538 KN-m


M(+ve)= xWulex2= 4.235 KN-m
M(-ve)= yWulex2= 4.017 KN-m
M(+ve)= yWulex2= 3.04 KN-m
Check for Depth:
Mulim=0.138fckbd2

Mumax= 5.538KN-m

d= 45.75 mm < 130mm


It is sufficient to resist the ultimate design moment.
Ast min= 0.12%bd=0.00121000155= 186 mm2
Reinforcement Details:

M u 0.87 Ast f y d (1

Ast f y
bdf ck

Ast= 120mm2

Mu= 5.538 KN-m


Actual Ast= 186 mm2

Assume bar diameter of 10 mm


Spacing:
S= dia of single bar/ Ast(provided)= 300 mm
Hence S= 300 mm
Torsion steel:
Ast = 0.75(Ast main)
= 156 mm2
Provide 6mm diameter bars @ 100 mm c/c distance
Check for deflection:
(L/D)max = (L/D)basic kt kc kf
= 40

Pt = 100 Ast/bd
= (L/D)prov = 24.96
Hence the deflection control is verified.