You are on page 1of 6

Gas Generator Set

NATURAL GAS
STANDBY
500 ekW 750 kVA 60 HZ 1800 RPM

Caterpillar is leading the power generation


marketplace with power solutions engine ered
to delive r unmatched flexibility, expandability,
relia bility a nd cost-e ffectiveness.

Image shown may not reflect actual package

FEATURES
FULL RANGE OF ATTACHMENTS
Wide range of bolt-on system expansion
attachments, factory designed and tested.
Flexible packaging options for easy and cost
effective installation.
PROVEN SYSTEM
Fully prototype tested.
Field proven in a wide range of applications
worldwide.
Certified torsional vibration analysis available
WORLDWIDE PRODUCT SUPPORT
Cat dealers provide extensive post sales
support including maintenance and repair
agreements
Cat dealers have over 1,800 dealer branch
stores operating in 200 countries

SM

The Cat SOS program cost effectively


detects internal engine component conditions,
even the presence of unwanted fluids and
combustion by-products

CAT G3412C GAS ENGINE


Robust high speed diesel block design provides
prolonged life and lower owning and operating costs
Designed for maximum performance on
low pressure gaseous fuel supply.
Simple open chamber combustion system for
reliability and fuel flexibility.
CAT GENERATOR
Designed to match performance and output
characteristics of Caterpillar gas engines
Industry leading mechanical and electrical design
High efficiency
CAT EMCP4.2 CONTROL PANEL
Simple user friendly interface and navigation
Easy integration with local building management
Fully-featured power metering and protection
Remote control and monitor capability options

STANDBY 500 ekW 750 kVA 60 Hz 1800 rpm


G3412C Product Consist (DTO)
System
Air Inlet
Cooling

Standard
Air cleaner, single element
Service indicator
Engine driven pump for jacket water
Package mounted radiator sized for 40C / 104 F ambient to 200m / 660 ft
Coolant drain lines with valves piped to edge of base
Cat Coolant
Low coolant sensor

Exhaust

Exhaust manifolds, watercooled


Stainless steel exhaust flex with two ship loose weld flanges

Fuel

1.5 to 5 psi pressure fuel regulator


Carburator sized for 800 - 1000 BTU/scf gas
NOx sensor based air-fuel-ratio control
Fuel safeties, energized to run fuel shutoff valve, and gas filter (optional)

Generator

SR4B self excited generator (permanent magnet optional) includes:


Class H insulation, Class F temperature rise (130 C Standby)
12 Lead (600 volt generators are 6 lead)
VR6 Voltage Regulator, 3-phase sensing with reactive droop, 2:1 Volts/Hz or 1:1 Volts/Hz
Power terminal strip termination
Extension box
Segregated low voltage (AC/DC) wiring panel
Random wound

Governing
Ignition
Lubrication

Woodward 2301A speed control with EG3P actuator


Digital Ignition System
Lubricating oil
Electric prelube pump
Oil filter
Oil drain line with valve piped to edge of base
Fumes disposal piped to front of radiator

Mounting

Wide, formed steel base


Linear vibration isolators between base and engine-generator

Starting / Charging

24V DC starting motor


45A charging alternator
Battery set w/ rack and cables
Battery disconnect switch

General

Paint -- Caterpillar Yellow except rails & radiators;


Crankshaft vibration damper
Lifting eyes
Operation and Maintenance Manuals; Parts Book.

STANDBY 500 ekW 750 kVA 60 Hz 1800 rpm


SPECIFICATIONS
CAT G3412C GAS ENGINE
4-Stroke-Cycle, Spark Ignited
Number of Cylinders
Bore mm (in)
Stroke mm (in)
Displacement L (cu in)
Compression Ratio
Aspiration
Cooling Type
Fuel System
Ignition
Governor Type
CAT SR4B GENERATOR
Frame size
Excitation
Pitch
Number of poles
Number of bearings
Number of leads
Insulation
IP rating
Alignment
Overspeed capability % of rated
Waveform deviation line to line, no load
Voltage regulator Voltage level adjustment
Voltage regulation, steady state
Voltage regulation with 3% speed change
Telephone Influence Factor (TIF)

V12
137 (5.4)
152 (6.0)
27.0 (1649)
11.4:1
Lean, Turbocharged
Separate JW/OC & AC
Low Pressure
Digital Ignition
Woodward 2301A

591
Self Excited
0.7333
4
1
12
Class H
Drip proof IP22
Pilot shaft
50 Hz 180%
60 Hz 150%
less than 5.0%
VR6
+/- 5.0%
+/- 0.5%
+/- 0.5%
less than 50

Consult ASC for available voltage

Materials and specifications are subject to change without notice.


The International System of Units (SI) is used in this publication.

CAT EMCP4.2 CONTROL PANEL


EMCP 4 controls including:
Run / Auto / Stop Control
Speed and Voltage Adjust
Purge Cycle Crank
24-volt DC operation
Environmental sealed front face
Text alarm/event descriptions
Digital indication for:
RPM
DC volts
Operating hours
Oil pressure (psi, kPa or bar)
Coolant temperature
Volts (L-L & L-N), frequency (Hz)
Amps (per phase & average)
ekW, kVA, kVAR, kW-hr, %kW, PF
Warning/shutdown with common LED indication of:
Low Oil pressure
High Coolant temperature
Overspeed
Emergency Stop
Failure to start (overcrank)
Low Coolant temperature
Low Coolant level
Programmable protective relaying functions:
Generator phase sequence
Over/Under voltage (27/59)
Over/Under Frequency (81 o/u)
Reverse Power (kW) (32)
Reverse reactive power (kVAr) (32RV)
Overcurrent (50/51)
Communications:
Six digital inputs (4.2 only)
Four relay outputs (Form A)
Two relay outputs (Form C)
Two digital outputs
Customer data link (Modbus RTU)
Accessory module data link
Serial annunciator module data link
Emergency Stop pushbutton
Compatible with the following:
digital I/o module
Local annunciator
Remote CAN annunciator
Remote Serial annunciator

STANDBY 500 ekW 750 kVA 60 Hz 1800 rpm


TECHNICAL DATA
G3412C Natural Gas Generator Set
Engine

Ref.

EM4706

EM0747

Type

G3412C

G3412C

11.4:1

11.4:1

Compression Ratio
Emission level (NOx )
Aftercooler Temperature

mg/Nm3 g/bhp-hr

851

2.0

421

1.0

Deg C Deg F

54

130

54

130

Package Performance* (1) (w/ pumps/fan)


Power Rating @ 0.8 pf

ekW Continuous

500

423

Power Rating @ 1.0 pf

ekW Continuous

535

451

Mechanical Power

bkW Continuous

563

475

Fuel Consumption (2)


100% load w/ fan

Nm3/hr scf/hr
3

158

5,908

137

5,126

75% load w/ fan

Nm /hr scf/hr

125

4,676

109

4,061

50% load w/ fan

Nm3/hr scf/hr

92

3,435

80

2,994

m ft

610

2000

1219

4000

Altitude Capability (3)


At 25 Deg C (77 Deg F) ambient, above sea level
Cooling System
Ambient air temperature

Deg C Deg F

25

77

25

77

Jacket water temperature ( Maximum outlet )

Deg C Deg F

99

210

99

210

Nm3/min scfm

40.9

100

36.2

1,395

Exhaust System
Combustion air inlet flow rate
Exhaust stack gas temperature

Deg C Deg F

450

842

369

696

Nm3/min ft3/min

44

3,904

39

3,247

Heat rejection to jacket water+oil cooler

kW Btu/min

425

24,160

429

24,387

Heat rejection to aftercooler

kW Btu/min

115

6,353

79

4,517

Heat rejection to exhaust (LHV to 120 Deg C)

kW Btu/min

238

13,535

173

9,838

Heat rejection to atmosphere from engine

kW Btu/min

64

3,632

55

3,153

Heat rejection to atmosphere from generator (typical)

kW Btu/min

30

1,730

30

1,730

Exhaust gas flow rate (Nm3 @ 0C, ft3/min @ stack T)


Heat Rejection

(4)

Generator
Votlage

480

480

Typical Temperature rise

Deg C

130

130

Typical motor starting capability @ 30% voltage dip (5)

skVA

956

956

Lubrication System
Standard sump refill with filter change

L Gal

170

45

170

45

mg/Nm3 g/bhp-hr

851

2.0

421

1.0

Emissions (6)
NOx @ 5% O2 (dry)

CO @ 5% O2 (dry)

mg/Nm g/bhp-hr

748

1.8

915

2.2

THC @ 5% O2 (dry)

mg/Nm3 g/bhp-hr

2227

5.2

2634

6.3

NMHC @ 5% O2 (dry)

mg/Nm3 g/bhp-hr

334

0.8

395

0.9

Exhaust O2 (dry)

8.6%

9.1%

STANDBY 500 ekW 750 kVA 60 Hz 1800 rpm

RATING DEFINITIONS AND CONDITIONS

(1) Standby Maximum output available for the duration of an emergency power outage
(typically less than 500 hours/year).
Ratings are based on low energy gas having a Low Heat Value (LHV) of 35.64 MJ/Nm3
(905 Btu/ft3).For values in excess of altitude. ambient temperature, inlet/exhaust restriction, or
different from the conditions listed, contact your Cat Dealer.

(2) Ratings and fuel consumption are based on ISO 3046/1 standard reference
conditions of 25 C (77 F) of ambient temperature and 100 kPa (29.61 in Hg) of
total barometric pressure, 30% relative humidity with 0, +5% fuel tolerance.

(3) Altitude capability is based on 2.5 kPa air filter and 5.0 kPa exhaust stack restrictions.

(4) Heat rejection Values based on nominal data with fuel tolerance of +/-2.5% and
2.5 kPa inlet and 5.0 kPa exhaust restrictions.

(5) Assume synchronous driver.

(6) Emissions data measurements are consistent with those described in EPA CFR 40
Part 89 Subpart D & E and ISO8178-1 for measuring HC, CO, PM NOX. Data shown is
based on steady state engine operating conditions of 25C (77F), 96.28 kPa (28.43 Hg)
and fuel having a LHV of 35.6 MJ/Nm3 (905 Btu/cu ft) and 80 Cat Methane Number at
101.60 kPa (30.00 in Hg) absolute and 0 C (32 F). Emission data shown is subject to
instrumentation, facility and engine fuel system adjustment.

STANDBY 500 ekW 750 kVA 60 Hz 1800 rpm


DIMENSIONS
Package Dimensions
Length

4540.2 mm

178.8 in

Width

2194.5 mm

82.9

See general dimension drawings

Height

2528.9 mm

99.6

for details

4383.5 kg

9664 lb

Approx. Shipping Weight

Note: Do not use for installation design.

(Drawing Number 45203056)

Information contained in this publication may be considered confidential. Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate
and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

www.Cat-ElectricPower.com
Media TBD (12/13)

2013 Caterpillar
All Rights Reserved.
Printed in U.S.A.

You might also like