IESNA-LM-80 (Measuring Lumen Maintenance of LED Light sources) is an approved method by
Lighting Engineering Association of North America (IESNA) for the third generation SSL products; it
mentioned the measurement standard and method. The main purpose is that measure and records the
LED lumen maintenance change along with time, in other word, it is applied to test LED aging life.
Compare with the traditional light source, theoretically LED life can reach to 50000 hours. So it is hard
to test the LED life, because it is impossible to light up the LED till it dies, and it is also unworkable
because there are so many different types and different power of LED, if the problem can not solve, it
will become a big resistance to develop and push LED products. Considering the real situation, IESNA
passed the LM-80-08 approved method, which provides the guidance and specification for measuring
and recording LED lumen vs time, and calculate the life time of LED luminaires in the end. Also it solves
an urgent problem for LED industry.
When we say LED lumen maintenance and LED aging life, we will talk about LM-80, TM-21, TM-82 and
etc. so it is necessary to explain them. LM-80-08 put forward the measurement method and then
obtains the data, TM-21 put forward the calculate method and then obtains the data. In those
standards, they mentioned L70, L50, L30 And etc. that means the time to 70% lumen maintenance,
time to 50% lumen maintenance and time to 30% lumen maintenance. From the data, we can find
lumen changing along with the time. Generally speaking, time to 70% lumen maintenance will be
defined as the LED life. According to LM-80, the test time should be no less than 6000h, and 10000h is
recommended. And during the test, temperature is limited at three points, first one is 55second one
is 85 and the third one is depends on the manufacturer. And generally, the test report should
includes the following information: number of LED light source test, description of LED light source,
description of auxiliary device, operating cycle, ambient conditions including airflow, temperature and
relative humidity, Drive current of the LED light source during lifetime test, Initial luminous flux and
forward voltage at photometric measurement current, Lumen maintenance data for each individual LED
light source along with median value, standard deviation, minimum and maximum lumen maintenance
value for all of the LED light sources, Observation of LED light source failures including the failure
conditions and time of failure, LED light source monitoring interval, Photometric measurement
uncertainty, Chromaticity shift reported over the measurement time.
In order to adapt to the standard, Lisun developed the LPCE-2(LMS-9000A) high accuracy
spectroradiometer and integrating sphere test system, this system not only meet the requirements of
CIE, EN and lm-79 clause 9.1, and also meet the requirements of LM-80. Base on the normal function,
Lisuns engineer developed new software to meet the requirements of LM-80. So LPCE-2 has two
software, one is to test the luminous flux, color temperature, color rending index, wavelength, spectrum,
light efficiency and etc. the other is to test and record the data of lumen vs time, according to the data,
we can generally predict the LED life. But the main function for this system is to test the photoelectric
and colorimetric parameters of LED, so it is not a standard way to test LED life, the test result and test
report can not regarded as the final evaluation. But along with the technology developing, LISUN push
LEDLM-80PL LED lumen maintenance and life test system into the market, this system is designed
according to LM-80-08, TM-82, TM-21 and etc. so it is completely meet the relevant standards.

Lisun Electronics Inc.

Sales@Lisungroup.com

www.Lisungroup.com

LEDLM-80PL is developed base on the mature system of LPCE-2 (LMS-9000A). In the hardware,
LEDLM-80PL still adopts the high accuracy CCD spectroradiometer to keep the high precision. And the
most important is the software, the software absorbs the essence of the LPCE - 2, and then combine
Arrhenius model to build a newly reliable LED life predict software. Users will only need to test the lamp
for hundreds of hours under certain temperature, then the software will calculate the time to 70% (50%,
30%) lumen maintenance at this temperature, it will greatly help to improve the test efficiency and the
accuracy and reliability of LED lumen maintenance testing.
We have a lot of customers who bought the LPCE-2 spectroradiometer and integrating sphere system,
like SGS Australia, World Testing Lab, TUV and etc. At the same time, lots of customers show their
interesting in LEDLM-80PL lumen maintenance and life test system. The reason why we can win so
many trust and support from the world famous companies is because we always practice the motto
right product, right price and right service. From the feedback, Lisun enjoy good reputation in the world
market. And we will always provide the high quality products and superior service to all of our
customers.

You might also like