You are on page 1of 76

$"#-&48*3&4

/6)"40."/
www.nuhasoman.com

INTRODUCTION
Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of:

i8FBU/VIBT0NBODFBTFMFTTMZTUSJWFUP

HV, MV and LV Cables

Enamelled Copper Wires

BDIJFWFQSPEVDUFYDFMMFODFUISPVHI

Oxygen Free Continuous Cast Copper Wire Rods

Drawn Copper Conductors

505"-26"-*5:."/"(&.&/5UPQSPWJEF
UIFCFTUWBMVFUPPVSDVTUPNFST*UJTPVS
NJTTJPOUPQSPEVDFHMPCBMMZDPNQFUJUJWF
QSPEVDUTUISPVHIDPOUJOVPVT
EFWFMPQNFOUPGQSPEVDUJPODBQBCJMJUJFT 
TLJMMTFUTBOETJNVMUBOFPVTMZ
DPOUSJCVUJOHUPJOEVTUSJBMBOE
FDPOPNJDEFWFMPQNFOUPG0NBOw

Our state-of-the-art manufacturing facilities with cutting edge technology ensure that our products meet with
highest quality standards. All our products utilize only OXYGEN FREE HIGH CONDUCTIVITY
ELECTRONIC GRADE Copper produced through the Outokompu UPCAST technology, producing minimum
99.99% pure copper with oxygen content less than 5 ppm. The usage of /XYGEN&REE(IGH#ONDUCTIVITY#OPPER
ENABLESUSINACHIEVINGQUALITYEXCELLENCE
Our range of World-class HV, MV and LV Cables includes Single & Multi Core Armoured and Un-armoured
Cables, Specialty, Control, Instrumentation and also LSF, FRLS, LSOH & Custom Cables to meet the
requirements of a broad spectrum of applications ranging from 0OWER$ISTRIBUTION )NDUSTRIAL 0ETROCHEMICAL /IL
'AS !ERONAUTICAL #ONSTRUCTIONS )NSTRUMENTATION (OSPITALS (OTELS3ECURITYETC
The Cables are produced in compliance to the requirements of BS, IEC, VDE, ASTM, ICEA & UL
specifications. The #ABLESAREROUTINELYTYPETESTED by acclaimed independent international certifying agencies
confirming compliance to respective standards.
Nuhas IS COMMITTED TO DELIVER QUALITY PRODUCTS that conform to relevant International standards and 1UALITY
ASSURANCEISTHEDRIVINGFORCEBEHINDTHE#OMPANYSOPERATIONS

/UR1UALITY-ANAGEMENT3YSTEMHASBEENCERTIlEDTOCONFORMTO)3/BY"!3%# 5+
Our quality cycle encompasses raw material and consumable sourcing, in-process production controls and
certification of finished goods prior to delivery. A well-equipped in-house quality assurance facility, manned by
qualified professionals from the industry, ensures that all products delivered meet stringent quality controls
and parameters. Our state-of-the-art laboratory is equipped to test as per relevant international standards as
also to individual customer specifications.
The company endeavours to cater to the domestic, regional and global markets while maintaining the sanctity
of our pristine environment.
.EWPRODUCTDEVELOPMENT is a continuing process at Nuhas Oman LLC and we at Nuhas Oman ceaselessly
strive to achieve product excellence through TOTAL QUALITY MANAGEMENT to provide the best value to
our customers.

NUHAS OMAN QUALITY & RELIABILITY.


1

SINGLE CORE PVC INSULATED CABLES


Type

H05V-U, H07V-U, H07V R

Standards

BS 6004:2000

Construction

1) Oxygen Free
Electronic
Copper Conductor
2) PVC Insulation

Packing

Applications

Max. Operating Temperature: 70C


Rated Voltage: 300/500 V (H05V-U)
450/750 V(H07V-U, H07V-R)

Technical
Data

In rolls of 100 yards, spools,


drums or as per customer
requirements

In dry rooms, in apparatus, switch and


distribution boards, for laying in conduit
on and under plaster and on insulating
supports above plaster

SINGLE CORE PVC INSULATED FLEXIBLE CABLES


Type

H05V-K, H07V-K

Standards

BS 6004:2000

Construction

1) Fine stranded Oxygen


Free Electronic copper
wire
2) PVC Insulation

Packing
NOMINAL CROSS
SECTION
(mm2)
H05V-U 300/500 V
0.50
0.75
1.0
H07V-U 450/750 V
1.5
2.5
4
6
H07V-R 450/750 V
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

CLASS OF
COPPER
CONDUCTOR

INSULATION
THICKNESS

MAX. OVERALL
DIAMETER

APPROX. NET
WEIGHT

(mm Nominal)

(mm)

(kg/km)

STANDARD
LENGTH

1
1
1

0.6
0.6
0.6

2.3
2.5
2.7

9
11
14

Yards
100
100
100

1
1
1
1

0.7
0.8
0.8
0.8

3.2
3.9
4.4
5.0

21
32
47
66

100
100
100
100

2
2
2
2

0.7
0.8
0.8
0.8

3.3
4.0
4.6
5.2

21
32
47
66

100
100
100
100
Meters
300
300
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8

6.7
7.8
9.3
10.5
11.9
13.6
15.7
17.2
19.0
21.1
23.8
26.5
29.6
33.0
36.7

115
175
260
350
480
670
925
1150
1415
1775
2320
2895
3695
4720
6030

In rolls of 100 yards, spools,


drums or as per customer
requirements

NOMINAL CROSS
SECTION
(mm2)

CLASS OF
COPPER
CONDUCTOR

Applications

Flexible wire, for protected installation in


equipment and lighting fitting conduit or
under plaster

Technical
Data

Max. Operating Temperature: 700C


Rated Voltage: 300/500 V H05V-K
450/750 V H07V-K

INSULATION
THICKNESS

MAX. OVERALL
DIAMETER

APPROX. NET
WEIGHT

(mm Nominal)

(mm)

(kg/km)

H05V-K 300/500 V

STANDARD
LENGTH

Yards

0.5

0.6

2.5

100

0.75

0.6

2 .7

11

100

1.0

0.6

2.8

14

100

H07V-K 450/750 V
1.5

0.7

3.4

21

100

2.5

0.8

4.1

32

100

0.8

4.8

47

100

0.8

5.3

66

100

10

1.0

6.8

110

300

16

1.0

8.1

170

300

25

1.2

10.2

266

1000

35

1.2

11.7

360

1000

50

1.4

13.9

494

1000

70

1.4

16.0

696

1000

Meters

95

1.6

18.2

965

1000

120

1.6

20.2

1203

1000

150

1.8

22.5

1483

1000

185

2.0

24.9

1852

1000

240

2.2

28.4

2424

1000

HEAT RESISTANT SINGLE CORE PVC INSULATED CABLES


Type

H07V2-R
H07V2-U

Standards

BS 6004:2000

Construction

1) Oxygen Free Electronic


Copper Conductor
2) HR PVC Insulation

Packing

Applications

In rolls of 100 yards, spools,


drums or as per customer
requirements

NOMINAL CROSS
SECTION
(mm2)

CLASS OF
COPPER
CONDUCTOR

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 450/750 V

INSULATION
THICKNESS

MAX. OVERALL
DIAMETER

APPROX. NET
WEIGHT

(mm Nominal)

(mm)

(kg/km)

0.7

3.2

21

100
100

H07V2-U 450/750 V
1.5

In dry rooms, in apparatus, switch and


distribution boards, for laying in conduit
on and under plaster and on insulating
supports above plaster

STANDARD
LENGTH

2.5

0.8

3.9

0.8

4.4

47

100
100

0.8

5.0

66

1.5

0.7

3.3

21

100

2.5

0.8

4.0

32

100

0.8

4.6

47

100

0.8

5.2

66

100

H07V2-R 450/750 V

Meters
10

1.0

6.7

110

300

16

1.0

7.8

170

300

25

1.2

9.3

255

1000

35

1.2

10.5

345

1000

50

1.4

11.9

470

1000

70

1.4

13.6

665

1000

95

1.6

15.7

920

1000

120

1.6

17.2

1145

1000

150

1.8

19.0

1410

1000

185

2.0

21.1

1765

1000

240

2.2

23.8

2310

1000

300

2.4

26.5

2885

1000

400

2.6

29.6

3685

1000

500

2.8

33.0

4710

1000

630

2.8

36.7

6030

500

Type

H07V2K

Standards

BS 6004:2000

Construction

1) Fine stranded Oxygen Free


Electronic copper wire
2) HR PVC Insulation

Packing

In rolls of 100 yards, spools,


drums or as per customer
requirements

Applications

Flexible wire, for protected installation


in equipment and lighting fitting
conduit or under plaster

Technical
Data

Max. Operating Temperature: 900C


Rated Voltage: 450/750 V

Yards

32

HEAT RESISTANT SINGLE CORE PVC INSULATED FLEXIBLE CABLES

NOMINAL CROSS
SECTION
(mm2)

CLASS OF
COPPER
CONDUCTOR

INSULATION
THICKNESS

MAX. OVERALL
DIAMETER

APPROX. NET
WEIGHT

(mm Nominal)

(mm)

(kg/km)

H07V2-K 450/750 V
1.5

STANDARD
LENGTH

Yards
5

0.7

3.4

21

100

2.5

0.8

4.1

32

100

0.8

4.8

47

100

0.8

5.3

66

100
Meters

10

1.0

6.8

110

16

25

35

50

70
95

1.0

8.1

170

300

1.2

10.2

266

1000

1.2

11.7

360

1000

1.4

13.9

494

1000

1.4

16.0

696

1000

1.6

18.2

965

1000

120

1.6

20.2

1203

1000

150

1.8

22.5

1483

1000

185

2.0

24.9

1852

1000

240

2.2

28.4

2424

1000

300

FLEXIBLE CIRCULAR TWIN 2, 3, 4 & 5 CORE CABLES


Reference
Standards

BS 6500:2000

Construction

1) Oxygen Free Electronic

Applications

For household appliances under


medium mechanical stresses, also
in damp and wet conditions

Copper Conductor Class 5


2)
3)
Packing

FIRE ALARM / SIGNAL CABLES

PVC Insulation Type TI 2


PVC Sheath Type TM 2

Technical
Data

In coils/drums or as per customer


requirements

Rated Voltage: 300/500 V


Temperature: 70C

Nominal Cross
Section

Nominal
Insulation
thickness

Nominal
Sheath
Thickness

Approx. cable
dia.

Approx. weight
per km.

mm2

(mm)

(mm)

(mm)

(kg.)

0.75

0.6

0.8

6.5

1.0

0.6

0.8

6.7

75

1.5

0.7

0.8

7.8

100

2.5

0.8

1.0

9.5

150

0.75

0.6

0.8

6.7

75

1.0

0.6

0.8

7.0

90

1.5

0.7

0.9

8.4

120

2.5

0.8

1.0

10.6

185

0.75

0.6

0.80

7.5

90

1.0

0.6

0.90

8.0

110

1.5

0.7

1.00

9.5

160

2.5

0.8

1.10

11.6

230

0.75

0.6

0.9

8.2

105

1.0

0.6

0.9

8.7

120

1.5

0.7

1.10

10.6

175

2.5

0.8

1.20

13.0

265

No. of cores

70

Reference
Standards

BS 7629-1,
BS 6387 Category CWZ

Construction

1) Oxygen Free Electronic Copper


Conductor
2) Mica tape
3) FRLSOH Insulation
4) Overall Screen with Aluminium
Mylar tape and Tinned copper drain
wire
5) FRLSOH Sheath

Packing

Applications

requirements due to excellent data/


signal transmission characteristics

Technical
Data

In coils/drums or as per customer


requirements

In populated places where there


is risk of fire. Can be used in
wide variety of applications
including voice alarm, fire and
security circuits and networking

Voltage: 300/500 V
Temperature: 70C

No. of cores

Nominal Cross
Section

Nominal
Insulation
thickness

Approx. cable dia.

Approx. weight per


km.

(No.)

(mm2)

(mm)

(mm)

(kg.)

1.0

0.6

7.3

70

1.5

0.7

8.7

97

2.5

0.8

9.9

130

1.0

0.6

7.7

90

1.5

0.7

9.2

125

2.5

0.8

10.5

170

FLAT CABLES WITH EARTH CONDUCTOR

FLAT CABLES WITHOUT EARTH CONDUCTOR


Reference
Standards

BS 6004:2000

Construction

1) Oxygen Free Electronic


Copper Conductor
2) PVC Insulation
3) PVC Sheath

Packing

Applications

In drums or as per customers


requirements

Technical
Data

Fixed installation in dry or damp


premises, electric power & lighting
devices, telecommunication appliances

Voltage: 300/500 V.
Temperature : 700 C

No. of cores

Nominal cross-sectional
area of conductors
mm2

Radial thickness of
Insulation (mm)

Mean overall dimension


(mm)

2
2
2
2
2
2
2
3
3
3
3
3
3
3

1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0

0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0

4.7 x 7.4
5.4 x 8.4
6.2 x 9.8
7.2 x 11.5
8.0 x 13.0
9.6 x 16.0
11.0 x 18.5
4.7 x 9.8
5.4 x 11.5
6.2 x 13.5
7.4 x 16.5
8.0 x 18.0
9.6 x 22.5
11.0 x 26.5

Standards

BS 6004:2000

Construction

1) Oxygen Free Electronic


Copper Conductor
2) PVC Insulation
3) PVC Sheath
4) Earth Conductor

Packing

In drums or as per customer


requirements

Applications

Fixed installation
premises

Technical
Data

Voltage: 300/500 V.
Temperature : 700C

No. of cores

Copper
conductor
mm2

Thickness of
Insulation (mm)

Approx. overall
dimension (mm)

2
2
2
2
2
2
2
3
3
3
3
3
3
3

1.0
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
4.0
6.0
10.0
16.0

0.6
0.7
0.8
0.8
0.8
1.0
1.0
0.6
0.7
0.8
0.8
0.8
1.0
1.0

4.7 x 8.6
5.4 x 9.6
6.2 x 11.5
7.2 x 13.0
8.0 x 15.0
9.6 x 19.0
11.0 x 22.5
4.7 x 11.0
5.4 x 12.5
6.2 x 14.5
7.4 x 18.0
8.0 x 20.0
9.6 x 25.5
11.0 x 29.5

in

dry

or

damp

Earth Conductor,
minimum nominal crosssectional area
mm2
1
1
1.5
1.5
2.5
4
6
1
1
1
1.5
2.5
4
6

SINGLE CORE THERMOSETTING INSULATED LSF WIRING CABLES


Type

H05Z-U , H07Z- U, HO7Z- R

Reference
Standards

BS 7211: 98

Construction

1) Oxygen Free Electronic


Copper Conductor
2) Thermosetting / LSF
Insulation

Applications

Technical
Data
Packing

NOMINAL CROSS
SECTION
(mm2)
H05Z-U 300/500 V
0.50
0.75
1.00
H07Z-U 450/750 V
1.5
2.5
4.0
6.0
H07Z-R 450/750 V
1.5
2.5
4.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

In rolls of 100 yards, spools,


drums or as per customer
requirements.

CLASS OF
COPPER
CONDUCTOR

These types of Cables are having


self-extinguishing behaviour
without halogenidric acids emission.
Furthermore toxic and corrosive gases
and smoke evolution is reduced to
very low level. These characteristics
make this ideal for usage where safety
behaviour is important at public places
in case of fire.
Max. Operating Temperature: 90C
Rated Voltage: 300/500 V H05Z-U
450/750 V H07Z- U, HO7Z- R,

Requirements
for LSF Cables

MAX. OVERALL
DIAMETER

APPROX. NET
WEIGHT

(mm)

(mm)

(kg/km)

1
1
1

0.6
0.6
0.6

2.3
2.5
2.7

9
11
14

Yards
100
100
100

1
1
1
1

0.7
0.8
0.8
0.8

3.2
3.9
4.4
5.0

21
32
47
66

100
100
100
100

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

0.7
0.8
0.8
0.8

3.3
4.0
4.6
5.2

1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8

6.7
7.8
8.2
9.3
10.9
12.6
14.7
16.2
17.8
20.1
22.8
25.3
29.0
32.2
35.4

10

Reference
Standards

BS 7211: 98

Construction

1) Oxygen Free Electronic

21
32
47
66
110
170
255
345
470
665
920
1150
1415
1765
2310
2890
3685
4700
6000

STANDARD
LENGTH

100
100
100
100
Meters
300
300
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500

Applications

These types of Cables are having


self-extinguishing behaviour
without halogenidric acids emission.
Furthermore toxic and corrosive gases
and smoke evolution is reduced to
very low level. These characteristics
make this ideal for usage where safety
behaviour is important at public places
in case of fire

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 300/500 V

Requirements
for LSF Cables

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5% by
weight

Copper Conductor
2) Thermosetting / LSF
Insulation
3) LSF Sheath

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5% by
weight

INSULATION
THICKNESS

2
2
2
2

SINGLE CORE THERMOSETTING INSULATED SHEATHED LSF CABLES

Packing

NOMINAL
CROSS
SECTION

In rolls of 100 yards, spools,


drums or as per customer
requirements.

CLASS OF COPPER
CONDUCTOR

(mm2)

INSULATION
THICKNESS

SHEATH
THICKNESS

MAX. OVERALL
DIAMETER

APPROX.
NET WEIGHT

(mm)

(mm)

(mm)

(kg/km)

4.8

28

1.0

0.7

0.8

1.0

0.7

0.8

4.9

28

1.5

0.7

0.8

5.0

36

1.5

0.7

0.8

5.2

36

2.5

0.7

0.8

5.5

50

2.5

0.7

0.8

5.6

51

0.7

0.8

6.0

72

0.7

0.9

6.4

75

0.7

0.9

6.8

95

0.7

0.9

7.1

98

10

0.7

0.9

8.1

150

16

0.7

0.9

9.2

220

25

0.9

1.0

11.4

300

35

0.9

1.1

12.8

400

11

TWO CORE THERMOSETTING INSULATED SHEATHED LSF CABLES


Reference
Standards

BS 7211: 98

Construction

1) Oxygen Free Electronic


Copper Conductor
2) Thermosetting / LSF
Insulation
3) LSF Sheath

Packing

CONDUCTOR
SIZE
(mm2)

Applications

In rolls of 100 yards, spools,


drums or as per customer
requirements

CLASS OF
COPPER
CONDUCTOR

These types of Cables are having


se l f-e x ti n g u i sh i n g b e h av i our
without halogenidric acids emission.
Furthermore toxic and corrosive gases
and smoke evolution is reduced to
very low level. These characteristics
make this ideal for usage where safety
behaviour is important at public places
in case of fire

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 450/750 V

Requirements
for LSF Cables

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5% by
weight

THREE CORE THERMOSETTING INSULATED SHEATHED LSF CABLES


Reference
Standards

BS 7211: 98

Construction

1) Oxygen Free Electronic


Copper Conductor
2) Thermosetting / LSF
Insulation
3) LSF Sheath

Packing

INSULATION
THICKNESS

INNER
COVERING
THICKNESS

SHEATH
THICKNESS

MAX. OVERALL
DIAMETER

CONDUCTOR
SIZE

(mm)

(mm)

(mm)

(mm)

(mm2)

In rolls of 100 yards, spools,


drums or as per customer
requirements

Applications

These types of Cables are having


self-extinguishing behaviour
without halogenidric acids emission.
Furthermore toxic and corrosive gases
and smoke evolution is reduced to
very low level. These characteristics
make this ideal for usage where safety
behaviour is important at public places
in case of fire

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 450/750 V

Requirements
for LSF Cables

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5% by
weight

CLASS OF
COPPER
CONDUCTOR

INSULATION
THICKNESS
(mm)

INNER
COVERING
THICKNESS
(mm)

0.7

0.4

SHEATH
THICKNESS

MAX. OVERALL
DIAMETER

(mm)

(mm)

1.2

10.0

2x1.0

0.7

0.4

1.2

9.5

3x1.0

2x1.0

0.7

0.4

1.2

9.7

3x1.0

0.7

0.4

1.2

10.2

0.7

0.4

1.2

10.6

2x1.5

0.7

0.4

1.2

10.1

3x1.5

2x1.5

0.7

0.4

1.2

10.3

3x1.5

0.7

0.4

1.2

10.9

2x2.5

0.7

0.4

1.2

11.0

3x2.5

0.7

0.4

1.2

11.6

0.7

0.4

1.2

11.9

2x2.5

0.7

0.4

1.2

11.3

3x2.5

2x4

0.7

0.4

1.2

12.1

3x4

0.7

0.4

1.2

12.7

0.7

0.4

1.2

13.1

0.7

0.4

1.2

14.0

2x4

0.7

0.4

1.2

12.4

3x4

2x6

0.7

0.4

1.2

13.2

3x6

2x6

0.7

0.4

1.2

13.7

3x6

0.7

0.4

1.4

15.0

0.7

0.6

1.4

16.9

2x10

0.7

0.4

1.4

15.5

3x10

2x10

0.7

0.6

1.4

16.7

3x10

0.7

0.6

1.4

17.5

0.7

0.6

1.4

19.9

2x16

0.7

0.6

1.4

18.8

3x16

2x25

0.9

0.8

1.4

23.2

3x25

0.9

0.8

1.4

24.7

2x35

0.9

0.8

1.6

26.0

3x35

0.9

0.8

1.6

27.6

12

13

FOUR CORE THERMOSETTING INSULATED SHEATHED LSF CABLES


3FGFSFODF
4UBOEBSET

BS 7211: 98

Construction

1) Oxygen Free Electronic


Copper Conductor
2) Thermosetting / LSF
Insulation
3) LSF Sheath

Packing

CONDUCTOR
SIZE

Applications

In rolls of 100 yards, spools,


drums or as per customer
requirements

CLASS OF
COPPER
CONDUCTOR

(mm2)

These types of Cables are having


self-extinguishing
behaviour
without
halogenidric acids emission. Furthermore
toxic and corrosive gases and smoke
evolution is reduced to very low level.
These characteristics make this ideal for
usage where safety behaviour is important
at public places in case of fire

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 450/750 V

Requirements
for LSF Cables

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5%
by weight

FIVE CORE THERMOSETTING INSULATED SHEATHED LSF CABLES


Reference
Standards

BS 7211: 98

Construction

1) Oxygen Free Electronic


Copper Conductor
2) Thermosetting / LSF
Insulation
3) LSF Sheath

Packing

In rolls of 100 yards, spools,


drums or as per customer
requirements

INSULATION
THICKNESS

INNER
COVERING
THICKNESS

SHEATH
THICKNESS

MAX. OVERALL
DIAMETER

CONDUCTOR
SIZE

(mm)

(mm)

(mm)

(mm)

(mm2)
1

CLASS OF
COPPER
CONDUCTOR

Applications

These types of Cables are having


self-extinguishing
behaviour
without
halogenidric acids emission. Furthermore
toxic and corrosive gases and smoke
evolution is reduced to very low level.
These characteristics make this ideal for
usage where safety behaviour is important
at public places in case of fire

Technical
Data

Max. Operating Temperature: 90C


Rated Voltage: 450/750 V

Requirements
for LSF Cables

Oxygen index - Minimum 30


Smoke density - Maximum 60%
Acid gas
- Maximum 0.5%
by weight

INSULATION
THICKNESS

INNER
COVERING
THICKNESS

SHEATH
THICKNESS

MAX. OVERALL
DIAMETER

(mm)

(mm)

(mm)

(mm)

0.7

0.4

1.2

11.5

4x1.0

0.7

0.4

1.2

11.2

5x1.0

4x1.0

0.7

0.4

1.2

11.5

5x1.0

0.7

0.4

1.2

11.9

4x1.5

0.7

0.4

1.2

11.4

5x1.5

0.7

0.4

1.2

12.3

0.7

0.4

1.2

12.6

4x1.5

0.7

0.4

1.2

11.7

5x1.5

4x2.5

0.7

0.4

1.2

12.6

5x2.5

0.7

0.4

1.2

13.6

0.7

0.4

1.2

13.9

4x2.5

0.7

0.4

1.2

12.8

5x2.5

4x4

0.7

0.4

1.2

13.8

5x4

0.7

0.4

1.4

15.5

4x4

0.7

0.4

1.2

14.0

5x4

0.7

0.6

1.4

16.4

5x6

0.7

0.6

1.4

17.5

4x6

0.7

0.4

1.4

15.7

4x6

0.7

0.6

1.4

16.7

5x6

0.7

0.6

1.4

18.1

0.7

0.6

1.4

20.0

0.7

0.6

1.4

20.9

4x10

0.7

0.6

1.4

18.4

5x10

4x10

0.7

0.6

1.4

19.2

5x10

4x16

0.7

0.6

1.4

21.8

5x16

0.7

0.8

1.4

24.2

0.9

1.0

1.6

30.5

0.9

1.0

1.6

33.6

4x25

0.9

0.8

1.6

27.5

5x25

4x35

0.9

1.0

1.6

30.7

5x35

14

15

GENERAL CABLE TECHNICAL DATA


& RATING FACTORS

16

Current carrying capacities at ambient temperature 30C


The tabulated current carrying capacities relate to continuous loading and are also known as the "full thermal ratings"
implying that the cables will operate at their maximum conductor continuous temperature of 70C. The data is extracted
from lEE Wiring Regulations 16th Edition.
The tabulated current rating capacities also relate to installations where the overload protection is afforded by a fuse to
BS 88 or BS 1361 or a miniature circuit breaker to BS 3871. Where the conductor is protected by a semi-enclosed fuse
to BS 3036, the size of the conductor is to be such that its tabulated current carrying capacity is not less than the value
of the fuse rating adjusted by multiplier 1.38 in addition to the correction factors for ambient temperature, thermal
insulation and grouping. For details refer to clause 6.2 of Appendix 4 - lEE Wiring Regulations 16th Edition.

Volt Drop Data


For a given cable run, to calculate the voltage drop (in mV), the tabulated value (mV/A/m) has to be multiplied by
the cable route length in metres and the design current. For three-phase circuits the tabulated mV/A/m values relate
to the line voltage.
For cables of 16mm2 or less cross sectional area, the inductance can be ignored and mV/A/m values are based on
resistance (r) only. For cables of cross sectional area greater than 16mm2, mV/A/m values based on resistance (r)
and inductance (x) are significant. However for brevity, Table, for single core cables of sizes 25mm2 & 35mm2, list
(mV/A/m) z values based on total impedance (z) only.
Where the power factor of the A.C. load is widely different from the cable power factor, use of (mV/A/m) z values for
calculating the volt drop may give a pessimistically high value. For detailed information, reference should be made to
Appendix 4 of the lEE Wiring Regulations 16th Edition.

Table 1
Single Core PVC Insulated Non-Sheathed Cables - Cables
in conduit on a wall or ceiling or in trunking (Reference Method 3)
Conductor
Cross
Sectional
Area
mm2

Current
carrying
Capacities
(amperes)
2 cables
single
phase ac
or dc

Volt Drop
(mV/A/m)

3 or 4 2 cables 3 or 4
cables
single
cables
three phase ac three
phase
phase
ac
ac

Conductor
Cross
Sectional
Area
mm 2

Current
carrying
capacities
(amperes)
2 cables
single
phase ac
or dc

3 or 4
three
phase
ac

Volt Drop
(mV/A/m)

2 cables single
phase ac

3 or 4 cables
three phase ac

13.5

12

44

38

50

151

134

0.95

0.30 1.00 0.81 0.26 0.85

1.5

17.5

15.5

29

25

70

192

171

0.65

0.29 0.72 0.56 0.25 0.61

2.5

24

21

18

15

95

232

207

0.49

0.28 0.56 0.42 0.24 0.48

32

28

11

9.5

120

269

239

0.39

0.27 0.47 0.33 0.23 0.41

41

36

7.3

6.4

150

300

262

0.31

0.27 0.41 0.27 0.23 0.36

185

341

296

0.25

0.27 0.37 0.22 0.23 0.32

10

57

50

4.4

3.8

240

400

346

0.195 0.26 0.33 0.17 0.23 0.29

16

76

68

2.8

2.4

300

458

394

0.160 0.26 0.31 0.14 0.23 0.27

+25

101

89

1.8

1.55

400

546

467

0.130 0.26 0.29 0.12 0.22 0.25

+35

125

110

1.3

1.10

500

626

533

0.110 0.26 0.28 0.10 0.22 0.25

630

720

611

0.094 0.25 0.27 0.08 0.22 0.24

+ Volt drop for sizes 25mm2 and 35mm2 are based on total impedance 'z' only. For 'r' and 'x: data, lEE Wiring
Regulations 16th Edition should be referred to.
NOTE: Data in the above table is based on lEE Wiring Regulations 16th Edition. The current carrying capacities of
Heat Resistant PVC insulated cables are higher, please refer to Technical Department if data is required.

17

Thermal Insulation
Table 4
Conductor Resistance

Current ratings pertaining to cables or cable conduits totally surrounded by thermally insulating material are not
included in the above tables. For such situations, in the absence of precise information, a rating factor of 0.5 may be
applied to the appropriate current ratings.
For multi-core cables, current ratings of cables installed in thermally.insulated ceilings but in contact with a thermally
conductive surface on one side are stated. For similar information applicable to single core cables, reference should
be made to the lEE Wiring Regulations 16th Edition.

Nominal
conductor area

Maximum
diameter of
conductor

Table2
Rating Factors For ambient temperature other than 30C, the tabulated
current ratings should be adjusted by factors as follows:

mm2

mm

Ambient temperature C

25

Heat resisting
Overload protection afforded by PVC (90C)*
device other than semi-enclosed
Ordinary PVC
fuse to BS 3036
(70C)

30

35

40

45

50

55

60

65

70

75

80

85

1.03 1.0 0.97 0.94 0.91 0.87 0.84 0.80 0.76 0.71 0.61 0.5 0.35
1.03 1.0 0.94 0.87 0.79 0.71 0.61 0.50 035

Heat resisting
PVC (90C)*

1.03 1.0 0.97 0.94 0.91 0.87 0.84 0.80 0.76 0.72 0.68 0.63 0.49

Semi-enclosed fuse to
BS 3036 (formerly coarse excess
Ordinary PVC
current protection)
(70C)

Correction factor
Number of circuits or multicore cables
5
6
7
8
9 10 12 14

ohm

1.38

12.1

50

8.30

0.387

1.5

1.59

12.1

70

10.00

0.268

2.5*

1.78

7.41

95

11.70

0.193

2.5

2.01

7.41

120

13.15

0.153

150

14.55

0.124

2.55

4.61

185

16.30

0.0991

3.12

3.08

240

18.75

0.0754

10

4.05

1.83

300

21.00

0.0601

16

4.85

1.15

400

23.90

0.0470

25

6.15

0.727

500

28.40

0.0366

35

7.25

0.524

630

31.70

0.0283

k = 0.115
A = Cross sectional Area of conductor
t = Duration in seconds
16

18

20

Enclosed in conductor trunking (Method 3


or 4) or bunched and clipped directly to non- 0.80 0.70 0.65 0.60 0.57 0.54 0.52 0.50 0.48 0.45 0.43 0.41 0.39 0.38
metallic surface (Method 1)
0.85 0.79 0.75 0.73 0.72 0.72 0.71 0.70

Spaced*

0.94 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90

Single layer multicore on


a perforated metal cable
tray, vertical or horizontal
(Method 11)

Touching

0.86 0.81 0.77 0.75 0.74 0.73 0.73 0.72 0.71 0.70

Spaced*

0.91 0.89 0.88 0.87 0.87

Wiring cables should be installed in accordance with lEE Wiring Regulations, 16th Edition or local installation
regulations.

0.90 0.85

Minimum internal radius at bends:

0.85

CABLE DIAMETER

Up to 10 mm

Single layer Multicore


touching on ladder
supports (Method 13)

0.86 0.82 0.80 0.79 0.78 0.78 0.78 0.77

The values of short circuit ratings derived from above formula based on the PVC insulated cable being fully loaded at
the start of the short circuit conductor temperature of 70C and final conductor temperature of 160C.

Touching

e.g. Short circuit rating of 300mm2 Cu conductor for 1 sec. I = 0.115 x 300/ 1
= 34.5kA/sec.

Single layer clipped


to a non-metallic
surface (Method 1)

Single layer single core on a Horizontal


perforated metal cable tray.
Vertical
touching (Method 11)

mm

mm2

Short circuit rating of copper conductor shall be calculated using following formula:
Short circuit current I = kA/ t
Where,

Table 3
Correction factors for groups of cables
(Ref.IEE wiring regulation sixteenth edition)

Maximum
conductor
resistance per
km at 20C

Conductor short circuit ratings

These factors are applicable only to ratings in Table1.

ohm

Maximum
diameter of
conductor

1.5*

1.03 1.0 0.97 0.94 0.91 0.87 0.84 0.69 0.48

Method of Installation

Maximum
Nominal
conductor
conductor area
resistance per
km at 20C

* 'Spaced ' means a clearance between adjacent surfaces of at least one cable diameter (D). Where the horizontal
clearances between adjacent cables exceeds 2D no correction factor need be applied.
Notes:
1. The factors in the table are applicable to groups of cables all of one size. The value of current derived from
application of the appropriate factors is the maximum continuous current to be carried by any of the cables in the
group.
2. If, due to known operating conditions, a cable is expected to carry not more than 30% of its grouped rating, it
may be ignored for the purpose of obtaining the rating factor for the rest of the group.
18

Wiring Cable Installation

Minimum internal radius


3 x cable diameter

Exceeding 10 mm but less than 25 mm

4 x cable diameter
6 x cable diameter

Exceeding 25 mm

19

20

21

22

/6)"40."/--$
10#PY 1PTUBM$PEF 
3VTBZM*OEVTUSJBM&TUBUF 4VMUBOBUFPG0NBO
5FM   'BY 
&NBJMNBSLFUJOH!OVIBTPNBODPN8FCTJUFXXXOVIBTPNBODPN


".FNCFSPGUIF"M#BIKB(SPVQ

"/*40$0.1"/:
/6.,5%#+3FW
%BUF

$"#-&48*3&4

108&3$0/530-$"#-&4

26"-*5:3&-*"#*-*5:

/6)"40."/

INTRODUCTION
Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of:

i8FBU/VIBT0NBODFBTFMFTTMZTUSJWFUP

HV, MV and LV Cables

Enamelled Copper Wires

BDIJFWFQSPEVDUFYDFMMFODFUISPVHI

Oxygen Free Continuous Cast Copper Wire Rods

Drawn Copper Conductors

505"-26"-*5:."/"(&.&/5UPQSPWJEF
UIFCFTUWBMVFUPPVSDVTUPNFST*UJTPVS
NJTTJPOUPQSPEVDFHMPCBMMZDPNQFUJUJWF
QSPEVDUTUISPVHIDPOUJOVPVT
EFWFMPQNFOUPGQSPEVDUJPODBQBCJMJUJFT 
TLJMMTFUTBOETJNVMUBOFPVTMZ
DPOUSJCVUJOHUPJOEVTUSJBMBOE
FDPOPNJDEFWFMPQNFOUPG0NBOw

Our state-of-the-art manufacturing facilities with cutting edge technology ensure that our products meet with
highest quality standards. All our products utilize only OXYGEN FREE HIGH CONDUCTIVITY
ELECTRONIC GRADE Copper produced through the Outokompu UPCAST technology, producing minimum
99.99% pure copper with oxygen content less than 5 ppm. The usage of /XYGEN&REE(IGH#ONDUCTIVITY#OPPER
ENABLESUSINACHIEVINGQUALITYEXCELLENCE
Our range of World-class HV, MV and LV Cables includes Single & Multi Core Armoured and Un-armoured
Cables, Specialty, Control, Instrumentation and also LSF, FRLS, LSOH & Custom Cables to meet the
requirements of a broad spectrum of applications ranging from 0OWER$ISTRIBUTION )NDUSTRIAL 0ETROCHEMICAL /IL
'AS !ERONAUTICAL #ONSTRUCTIONS )NSTRUMENTATION (OSPITALS (OTELS3ECURITYETC
The Cables are produced in compliance to the requirements of BS, IEC, VDE, ASTM, ICEA & UL
specifications. The #ABLESAREROUTINELYTYPETESTED by acclaimed independent international certifying agencies
confirming compliance to respective standards.
Nuhas IS COMMITTED TO DELIVER QUALITY PRODUCTS that conform to relevant International standards and 1UALITY
ASSURANCEISTHEDRIVINGFORCEBEHINDTHE#OMPANYSOPERATIONS

/UR1UALITY-ANAGEMENT3YSTEMHASBEENCERTIlEDTOCONFORMTO)3/BY"!3%# 5+
Our quality cycle encompasses raw material and consumable sourcing, in-process production controls and
certification of finished goods prior to delivery. A well-equipped in-house quality assurance facility, manned by
qualified professionals from the industry, ensures that all products delivered meet stringent quality controls
and parameters. Our state-of-the-art laboratory is equipped to test as per relevant international standards as
also to individual customer specifications.
The company endeavours to cater to the domestic, regional and global markets while maintaining the sanctity
of our pristine environment.
.EWPRODUCTDEVELOPMENT is a continuing process at Nuhas Oman LLC and we at Nuhas Oman ceaselessly
strive to achieve product excellence through TOTAL QUALITY MANAGEMENT to provide the best value to
our customers.

NUHAS OMAN QUALITY & RELIABILITY.


1

TABLE 1

XLPE INSULATED AND PVC SHEATHED ARMOURED CABLES

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) PVC sheath

Applications
For installation under ground, indoor ducts
where mechanical damage is not
expected. Suitable for comparatively
higher operating tenperature with XLPE
insulation.

XLPE INSULATED AND PVC SHEATHED ARMOURED CABLES

Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V

Three Core

Two Core

Single Core

Nominal Area of
conductor
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Thickness of
Insulation
mm
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

Nom
thickness of
bedding
mm
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6

Armour wire
Diameter
mm
0.9
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5

Nom
thickness of
oversheath
mm
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9

TABLE 1 (Contd.)

Approximate
overall diameter

Approximate
Cable Weight

mm
16.5
19.0
21.0
23.0
26.0
28.0
31.0
33.5
38.0
41.5
46.0
52.0
57.0
12.0
13.5
14.5
15.5
17.5
20.0
19.5
22.5
25.5
28.5
32.0
34.5
38.0
42.0
48.5
53.0
58.5
12.5
14.0
15.0
16.0
19.5
21.0
23.0
25.5
28.0
31.5
36.0
40.0
45.0
48.0
54.0
60.0
64.0

kg/km
690
950
1230
1490
1900
2320
2930
3580
4600
5680
7160
9315
11490
255
305
360
430
580
835
995
1395
1735
2250
3055
3635
4360
5495
7000
8450
10335
290
350
420
505
800
1035
1465
1840
2305
3030
4160
5050
6415
7580
9565
11640
14290

Reference standards

BS 5467

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) PVC sheath

Applications
For installation under ground, indoor ducts
where mechanical damage is not
expected. Suitable for comparatively
higher operating tenperature with XLPE
insulation.
Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V

Nominal Area of
conductor

Four Core

BS 5467

Five Core

Reference standards

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70

Thickness of
Insulation
mm
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1

Nom
thickness of
bedding
mm
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2

Armour wire
Diameter
mm
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0

Nom
thickness of
oversheath
mm
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
3.2
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.2

Approximate
overall diameter

Approximate
Cable Weight

mm
13.5
14.5
16.0
18.5
20.5
22.0
26.0
28.5
31.5
37.0
40.5
47.0
50.0
55.0
62.0
68.0
78.0
15.5
17.0
19.0
20.5
23.0
26.0
30.0
33.0
38.5
43.5

kg/km
330
400
490
700
920
1240
1860
2330
2940
4150
5300
6940
8170
9850
12480
15100
19710
420
500
700
855
1170
1660
2285
2530
3920
5170

TABLE 2

PVC INSULATED AND PVC SHEATHED ARMOURED CABLES

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) PVC sheath

Three Core

Two Core

Single Core

Nominal Area of
conductor
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Thickness of
Insulation
mm
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
2.8
3.0
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

Nom
thickness of
bedding
mm
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6

Armour wire
Diameter
mm
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5

Applications
For installation under ground, indoor ducts
where mechanical damage is not
expected.
TABLE 2 (Contd.)
Technical data
Max. Operating temperature: 70C

PVC INSULATED AND PVC SHEATHED ARMOURED CABLES

Voltage: 600/1000 V
Nom
thickness of
oversheath
mm
1.5
1.6
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.1
2.2
2.4
2.5
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.1
2.2
2.3
2.4
2.5
2.7
2.9
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
3.0

Approximate
overall diameter

Approximate
Cable Weight

mm
18.5
20.5
22.5
25.5
27.5
29.5
32.5
35.0
40.0
43.5
47.0
53.0
58.0
12.5
13.5
15.0
16.5
20.0
21.5
22.5
24.5
28.0
30.0
35.0
37.0
40.5
44.0
51.5
56.5
62.0
12.5
14.0
15.5
18.0
21.0
23.0
24.5
27.5
30.5
35.0
39.0
42.5
48.0
50.5
57.5
63.5
68.0

kg/km
755
985
1285
1625
1950
2345
2975
3625
4655
5770
7250
9250
11320
265
320
395
475
770
935
1225
1515
1900
2375
3300
3845
4590
5765
7350
8885
10850
295
370
465
650
925
1160
1595
1985
2520
3470
4470
5335
6805
7995
10150
12315
15000

Reference standards

BS 6346

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) PVC sheath

Nominal Area of
conductor

Four Core

BS 6346

Five Core

Reference standards

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70

Thickness of
Insulation
mm
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4

Nom
thickness of
bedding
mm
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2

Armour wire
Diameter
mm
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0

Applications
For installation under ground, indoor ducts
where mechanical damage is not
expected.
Technical data
Max. Operating temperature: 70C
Voltage: 600/1000 V
Nom
thickness of
oversheath
mm
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
3.0
3.3
1.4
1.5
1.5
1.6
1.7
1.7
1.9
1.9
2.1
2.2

Approximate
overall diameter

Approximate
Cable Weight

mm
13.5
15.0
17.5
19.0
23.0
26.0
28.5
31.0
35.0
39.0
43.5
50.0
53.5
58.5
66.0
72.0
82.0
14.5
16.0
19.0
20.5
26.0
28.0
32.5
35.0
41.0
46.0

kg/km
340
430
640
765
1100
1575
2045
2520
3405
4375
5675
7305
8630
10400
13130
15895
20655
380
495
720
885
1450
1845
2530
2750
4280
5495

TABLE 3

XLPE INSULATED AND LSF SHEATHED ARMOURED CABLES

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) LSF sheath

Applications
These cables have self-extinguishing
behaviour without halogen acid gas
emission. Furthermore toxic and corrosive
gases and smoke emission is reduced to
very low level. These characteristics make
the cable ideal for use where safety
behaviour is important as at public places
in case of fire.
Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V

Three Core

Two Core

Single Core

Nominal Area of
conductor
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Thickness of
Insulation
mm
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

Nom
thickness of
bedding
mm
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6

Armour wire
Diameter
mm
0.9
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5

Nom
thickness of
oversheath
mm
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.5
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
2.6
2.8
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9

Approximate
overall diameter

Approximate
Cable Weight

mm
17.0
19.5
21.5
23.5
26.5
29.0
32.0
34.5
39.5
43.0
47.5
54.0
59.0
11.5
13.0
14.0
15.5
17.5
19.5
19.5
22.5
25.0
28.0
32.0
35.0
38.5
43.5
48.0
52.0
57.5
12.0
13.5
15.0
16.0
19.0
21.0
23.0
25.0
27.5
31.5
36.0
39.5
44.5
48.5
53.5
58.5
65.0

kg/km
705
965
1250
1510
1925
2345
2960
3610
4635
5715
7200
9355
11525
260
310
370
440
590
850
1010
1410
1755
2270
3080
3660
4385
5520
7025
8470
10450
295
360
430
515
815
1050
1485
1860
2330
3055
4190
5085
6450
7615
9595
11665
14305

TABLE 3 (Contd.)

XLPE INSULATED AND LSF SHEATHED ARMOURED CABLES


Reference standards

BS 6724

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) Galvanized steel wire armour for
multicore & aluminium wire for
single core cables
4) LSF sheath

Applications
These cables have self-extinguishing
behaviour without halogen acid gas
emission. Furthermore toxic and corrosive
gases and smoke emission is reduced to
very low level. These characteristics make
the cable ideal for use where safety
behaviour is important as at public places
in case of fire.
Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V

Nominal Area of
conductor

Four Core

BS 6724

Five Core

Reference standards

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70

Thickness of
Insulation
mm
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.6
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1

Nom
thickness of
bedding
mm
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2

Armour wire
Diameter
mm
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0

Nom
thickness of
oversheath
mm
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
2.2
2.3
2.4
2.6
2.7
2.9
3.2
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.2

Approximate
overall diameter

Approximate
Cable Weight

mm
13.0
14.5
16.0
18.0
20.5
22.5
25.5
27.5
31.0
36.5
40.5
46.0
50.0
55.0
61.5
67.0
76.5
14.0
15.5
17.0
19.5
22.0
26.0
30.5
34.0
39.5
45.0

kg/km
340
410
500
710
935
1255
1885
2355
2970
4185
5340
6985
8215
9890
12520
15285
19930
430
510
715
870
1190
1680
2315
2560
3960
5215

TABLE 4

XLPE INSULATED AND PVC SHEATHED UN - ARMOURED CABLES


Reference standards

Single core cables -BS7889/IEC60502-1


Multicore cables - IEC 60502-1

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) PVC sheath

Applications
For fixed installation in industrial areas,
buildings and similar applications but not
for direct burial in the ground. Suitable for
comparatively higher temperature with
XLPE insulation.
Technical data
Max. Operating temperature: 90C

TABLE 4 (Contd.)

XLPE INSULATED AND PVC SHEATHED UN - ARMOURED CABLES


Reference standards

Single core cables -BS7889/IEC60502-1


Multicore cables - IEC 60502-1

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) PVC sheath

Voltage: 600/1000 V

Three Core

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

mm
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0

mm
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.2
2.3
2.4
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.1
2.2
2.3
2.5
2.7
2.9
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.8
3.1

mm
14.0
16.0
18.0
20.0
22.0
24.5
27.5
30.5
34.0
38.0
42.5
47.5
53.0
10.0
11.0
12.0
13.0
15.0
16.5
16.0
18.0
20.5
23.0
26.0
28.5
32.0
34.5
41.5
45.5
51.0
10.5
11.5
12.5
14.0
16.0
17.5
18.0
20.5
23.5
26.5
30.0
33.5
37.5
40.5
46.5
52.5
57.0

kg/km
520
720
975
1215
1495
1830
2375
2955
3755
4805
6230
7940
9855
110
135
170
220
325
450
615
810
1060
1465
1985
2470
3045
3730
4880
6075
7715
130
165
220
285
435
615
880
1165
1535
2145
2895
3630
4480
5505
7165
8930
11365

Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V
Nominal Area of
conductor

Four Core

mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

Thickness of
Insulation

Five Core

Two Core

Single Core

Nominal Area of
conductor

Applications
For fixed installation in industrial areas,
buildings and similar applications but not
for direct burial in the ground. Suitable for
comparatively higher temperature with
XLPE insulation.

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70

Thickness of
Insulation

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

mm
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1

mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.3
2.4
2.6
2.8
3.0
3.3
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.1

mm
11.5
12.5
13.5
15.0
17.5
19.0
22.0
23.5
26.0
30.5
34.0
39.5
43.0
48.0
55.0
60.5
69.0
12.0
13.0
14.5
16.0
18.5
20.5
24.5
27.5
31.5
36.5

kg/km
155
200
270
355
545
795
1165
1530
2030
2840
3830
4825
5925
7320
9520
11860
15135
175
230
315
420
655
965
1450
1585
2560
3570

TABLE 5

PVC INSULATED AND PVC SHEATHED UN-ARMOURED CABLES

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) PVC sheath

Applications
For fixed installation in industrial areas,
buildings and similar applications but not for
direct burial in the ground.

Voltage: 600/1000 V

Three Core

Two Core

Single Core

Nominal Area of
conductor
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

TABLE 5 (Contd.)

Technical data
Max. Operating temperature: 70C

Thickness of
Insulation

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

mm
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
2.8
3.0
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6

mm
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.5
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.1
2.2
2.4
2.6
2.7
3.0
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.1
2.2
2.3
2.5
2.7
2.9
3.1

mm
14.0
16.0
18.0
20.0
22.0
24.0
27.0
30.0
33.5
37.0
41.0
45.0
50.0
10.5
11.5
13.5
14.5
16.5
18.0
17.0
19.0
22.0
24.5
28.0
30.0
33.5
36.0
43.5
48.0
54.0
11.0
12.0
14.0
15.5
17.5
19.0
19.5
22.0
25.0
28.5
32.5
35.5
39.5
42.5
49.0
55.5
60.0

kg/km
570
775
1055
1300
1595
1960
2545
3165
4000
5070
6480
8185
10175
120
150
205
255
370
495
675
880
1160
1575
2140
2625
3230
3965
5185
6430
8170
150
190
265
340
495
685
965
1265
1680
2305
3130
3870
4750
5845
7605
9480
11995

10

PVC INSULATED AND PVC SHEATHED UN-ARMOURED CABLES


Reference standards

IEC 60502-1

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) PVC sheath

Applications
For fixed installation in industrial areas,
buildings and similar applications but not for
direct burial in the ground.
Technical data
Max. Operating temperature: 70C
Voltage: 600/1000 V

Nominal Area of
conductor

Four Core

IEC 60502-1

Five Core

Reference standards

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70

Thickness of
Insulation

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

mm
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
0.8
0.8
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4

mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
2.4
2.5
2.7
2.9
3.1
3.4
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2

mm
12.0
13.0
15.5
16.5
19.0
21.0
23.5
25.0
28.0
32.0
37.0
42.0
45.5
50.0
57.5
64.0
72.0
12.5
13.5
16.0
17.5
20.0
22.0
26.5
29.0
34.0
38.5

kg/km
180
230
330
425
625
885
1280
1660
2215
3050
4140
5140
6300
7770
10100
12580
16005
205
265
380
495
745
1065
1595
1730
2805
3830

11

TABLE 6

TABLE 7

ARMOURED CONTROL CABLES - XLPE INSULATION

ARMOURED CONTROL CABLES - PVC INSULATION

Reference standards

BS 5467

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) Galvanized steel wire armour
4) PVC sheath

Applications
For installation underground, indoor ducts and
in open where mechanical protection is
required or for higher tensile stresses during
installation and operation. Suitable for
comparatively higher operating tenperature
with XLPE insulation.

Reference standards

BS 6346

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) Galvanized steel wire armour
4) PVC sheath

Applications
For installation underground, indoor ducts and
in open where mechanical protection is
required or for higher tensile stresses during
installation and operation
Technical data
Max. Operating temperature: 70C

Technical data
Max. Operating temperature: 90C

Voltage: 600/1000 V

Voltage: 600/1000 V
No. of
cores

Area of
conductor

Thickness of
Insulation

nos
7
12
19
27
37
48
7
12
19
27
37
48
7
12
19
27
37
48

mm2
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0

mm
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nom
thickness of
bedding
mm
0.8
0.8
0.8
1.0
1.0
1.0
0.8
0.8
1.0
1.0
1.0
1.2
0.8
1.0
1.0
1.0
1.2
1.2

Armour wire
Diameter
mm
0.9
1.25
1.25
1.6
1.6
1.6
0.9
1.25
1.6
1.6
1.6
2.0
1.25
1.6
1.6
1.6
2.0
2.0

12

Nom
thickness of
oversheath
mm
1.4
1.5
1.6
1.7
1.7
1.8
1.4
1.6
1.7
1.8
1.8
2.0
1.5
1.6
1.7
1.9
2.0
2.1

Approximate
Approximate
overall diameter Cable Weight
mm
15.0
19.0
21.5
26.0
28.5
32.0
16.5
22.0
26.0
30.0
33.0
38.5
19.5
25.0
29.0
34.0
38.5
43.5

kg/km
455
725
965
1380
1675
2080
590
965
1465
1845
2275
3080
850
1405
1850
2385
3360
4053

No. of
cores

Area of
conductor

Thickness of
Insulation

nos
7
12
19
27
37
48
7
12
19
27
37
48
7
12
19
27
37
48

mm2
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0

mm
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8

Nom
thickness of
bedding
mm
0.8
0.8
0.8
1.0
1.0
1.0
0.8
0.8
1.0
1.0
1.0
1.2
0.8
1.0
1.0
1.2
1.2
1.2

Armour wire
Diameter
mm
0.9
1.25
1.25
1.6
1.6
1.6
1.25
1.25
1.6
1.6
1.6
2.0
1.25
1.6
1.6
2.0
2.0
2.0

13

Nom
thickness of
oversheath
mm
1.4
1.5
1.6
1.7
1.8
1.9
1.5
1.6
1.7
1.8
1.9
2.1
1.6
1.7
1.8
2.0
2.1
2.2

Approximate
Approximate
overall diameter Cable Weight
mm
15.0
19.0
21.5
26.0
28.5
32.5
17.5
22.0
26.0
30.0
33.5
39.0
20.0
26.5
30.0
36.5
40.0
45.5

kg/km
470
815
1100
1625
1910
2320
735
1070
1625
2080
2645
3495
920
1555
2035
2995
3690
4495

TABLE 9

UN-ARMOURED CONTROL CABLES - XLPE INSULATION


TABLE 8

ARMOURED CONTROL LSF CABLES - THERMOSETTING INSULATION


Reference standards

BS 6724

Construction

1) Oxygen free Electronic


Copper Conductor
2) Thermosetting Insulation
3) Galvanized steel wire armour
4) LSF sheath

Voltage: 600/1000 V
Area of
conductor

Thickness of
Insulation

nos
7
12
19
27
37
48
7
12
19
27
37
48
7
12
19
27
37
48

mm2
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0

mm
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nom
thickness of
bedding
mm
0.8
0.8
0.8
1.0
1.0
1.0
0.8
0.8
1.0
1.0
1.0
1.2
0.8
1.0
1.0
1.0
1.2
1.2

IEC 60502-1

Construction

1) Oxygen free Electronic


Copper Conductor
2) XLPE Insulation
3) PVC sheath

Applications
These cables have self-extinguishing
behaviour without halogen acid gas emission.
Furthermore toxic and corrosive gases and
smoke emission is reduced to very low level.
These characteristics make the cable ideal for
use where safety behaviour is important as at
public places in case of fire.
Technical data
Max. Operating temperature: 90C

No. of
cores

Reference standards

Armour wire
Diameter
mm
0.9
1.25
1.25
1.6
1.6
1.6
0.9
1.25
1.6
1.6
1.6
2.0
1.25
1.6
1.6
1.6
2.0
2.0

14

Nom
thickness of
oversheath
mm
1.4
1.5
1.6
1.7
1.7
1.8
1.4
1.6
1.7
1.8
1.8
2.0
1.5
1.6
1.7
1.9
2.0
2.1

Approximate
Approximate
overall diameter Cable Weight
mm
15.0
19.0
21.5
26.0
28.5
32.0
16.5
22.0
26.0
30.0
33.0
38.5
19.5
25.0
29.0
34.0
38.5
43.5

kg/km
465
740
980
1405
1705
2115
600
980
1490
1875
2310
3130
865
1430
1880
2425
3415
4115

Applications
For fixed installation in industrial areas,
buildings and similar applications but not for
direct burial in the ground. Suitable for
comparatively higher temperature with XLPE
insulation.
Technical data
Max. Operating temperature: 90C
Voltage: 600/1000 V

No. of
cores

Area of
conductor

Thickness of
Insulation

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

nos
7
10
12
19
24
27
30
37
48
7
10
12
19
24
27
30
37
48
7
10
12
19
24
27
30
37
48

mm2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4

mm
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
2.1

mm
13.0
16.5
17.0
19.5
22.5
23.0
24.0
26.0
29.5
14.5
18.0
18.5
21.5
25.0
25.5
26.5
28.5
33.0
16.0
20.0
20.5
24.0
28.0
29.0
30.0
32.5
37.5

kg/km
230
315
355
510
630
690
755
900
1135
305
420
480
705
875
960
1055
1265
1625
420
580
670
995
1240
1370
1520
1840
2380

15

TABLE 10

UN-ARMOURED CONTROL CABLES - PVC INSULATION


Reference standards

IEC 60502-1

Construction

1) Oxygen free Electronic


Copper Conductor
2) PVC Insulation
3) PVC sheath

Applications
For fixed installation in industrial areas,
buildings and similar applications but not for
direct burial in the ground.
Technical data
Max. Operating temperature: 70C

TABLE 11

Maximum DC resistance and Construction of conductor as per BS EN 60228


Plain annealed copper stranded class 2 conductor

Voltage: 600/1000 V
No. of
cores

Area of
conductor

Thickness of
Insulation

Thickness of
oversheath

Approximate
overall diameter

Approximate
Cable Weight

nos
7
10
12
19
24
27
30
37
48
7
10
12
19
24
27
30
37
48
7
10
12
19
24
27
30
37
48

mm2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4

mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
1.8
1.8
1.8
1.8
1.9
2.0
2.0
2.1
2.3

mm
14.0
17.0
18.0
20.5
24.0
24.5
25.5
27.5
31.5
15.0
19.0
19.5
22.5
26.5
27.0
28.0
30.5
35.0
18.0
22.5
23.5
27.5
32.5
33.5
34.5
37.5
43.5

kg/km
275
375
425
615
765
840
920
1105
1415
355
490
560
825
1030
1135
1245
1515
1945
520
725
840
1250
1575
1760
1935
2355
3045

16

Nominal conductor
area mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Resistance of
conductor at 20C
per km ()
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

Minimum number of wires in conductor


Circular

Circular
compacted

Shaped

7
7
7
7
7
7
7
7
19
19
19
37
37
37
37
61
61
61
91
91
91

6
6
6
6
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

6
6
6
12
15
18
18
30
34
34
53
-

17

TABLE 12

Maximum resistance of armour for single and multicore XLPE insulated 600/1000 V cables
having aluminium and steel wire armour
(Maximum dc resistance per km of cable at 20C)
Nominal cross
sectional area of
conductor
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

Al wire armour
Single core

1.30
0.75
0.67
0.61
0.42
0.38
0.34
0.31
0.22
0.20
0.18
0.13
0.12

Galvanized Steel wire armour


Two core

10.2
8.8
7.9
7.0
6.0
3.7
3.7
2.6
2.3
2.0
1.4
1.3
1.2
0.82
0.73
0.67
0.59
-

Three core

9.5
8.2
7.5
6.7
4.0
3.5
2.5
2.3
2.0
1.8
1.3
1.2
0.78
0.71
0.63
0.58
0.52
-

Four core

8.8
7.7
6.8
4.3
3.7
3.1
2.3
2.0
1.8
1.2
1.1
0.76
0.68
0.61
0.54
0.49
0.35
-

Five core

8.2
6.8
6.2
3.9
3.4
2.2
1.8
1.6
1.1
0.94
-

TABLE 13

OVERHEAD LINE COPPER CONDUCTOR


Bare copper conductors
Reference standard: BS 7884:1997
Nominal
conductor area
mm2
10
14
16
16
25
32
32
35
50
50
70
70
95
100
120
125
150
150
185
185

No. of strands
& diameter

Approx. overall
diameter

Approx. net
weight

DC Resistance
at 20C

Minimum
breaking load

mm
7/1.35
7/1.60
3/2.65
7/1.70
7/2.10
3/3.75
7/2.46
7/2.50
7/3.00
19/1.80
7/3.55
19/2.10
19/2.50
7/4.30
19/2.80
19/2.90
19/3.20
37/2.25
19/3.55
37.2.50

mm
4.05
4.80
5.70
5.10
6.30
8.06
7.38
7.50
9.00
9.00
10.65
10.50
12.50
12.90
14.00
14.50
16.00
15.75
17.75
17.50

kg/km
89.82
126.2
148.3
142.4
217.3
296.9
298.2
308
443.5
435.8
621.1
593.2
840.7
911.2
1055
1131
1377
1334
1695
1647

km
1.8290
1.3030
1.1060
1.1540
0.7563
0.5520
0.5497
0.5337
0.3706
0.3819
0.2646
0.2806
0.1980
0.1810
0.1578
0.1471
0.1208
0.1264
0.0982
0.1024

N
3752
5267
6194
5946
9073
12400
12442
12860
18520
17700
25930
24090
34140
36540
42830
45940
55940
53880
68860
66490

18

GENERAL CABLE TECHNICAL DATA


& RATING FACTORS

TECHNICAL DATA
POWER CABLES - CURRENT RATINGS
Current ratings and Voltage drop of single core cables
Copper conductor XLPE insulated armoured/unarmoured cable
Nominal
conductor
area
mm2
50
70
95
120
150
185
240
300
400
500
630
800
1000

AC Current Ratings in Amp


In Ground
ARMRD
199
244
292
332
371
417
480
536
594
658
723
764
810

In Duct
ARMRD
200
240
282
316
342
377
421
459
488
527
568
593
630

Approximate Voltage Drop

In Air
UNARM
185
236
292
342
394
457
546
632
736
852
984
1118
1247

ARMRD
192
245
300
349
401
461
543
618
706
799
900
978
1061

In Ground
mV/A/m
0.88
0.63
0.48
0.4
0.34
0.29
0.25
0.22
0.21
0.19
0.18
0.18
0.17

In Ground Direct in ground in trefoil touching


In Duct - 3 cables flat touching
In Air
- 3 cables in trefoil touching
Installation Conditions considered for Current ratings
Ground Temperature
:
35C
Ambient air temperature
:
45C
Depth of laying
:
0.50m
Soil thermal Resistivity
:
1.20Cm/W
Max permissible operating temperature at rated current:
90C
Note: for other installation conditions please refer appropriate rating factors
The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development

21

In Duct
mV/A/m
0.92
0.69
0.55
0.47
0.42
0.38
0.34
0.31
0.29
0.27
0.25
0.24
0.23

In Air
mV/A/m
0.86
0.61
0.46
0.38
0.32
0.27
0.23
0.2
0.19
0.17
0.16
0.16
0.15

Nominal
conductor
area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

In Ground
In Duct
In Air

POWER CABLES - CURRENT RATINGS

POWER CABLES - CURRENT RATINGS

Current ratings and Voltage drop of two core cables

Current ratings and Voltage drop of three and four core cables

Copper conductor, XLPE insulated armoured/unarmoured cable

Copper conductor, XLPE insulated armoured/unarmoured cable

AC Current Ratings in Amp


In Ground
ARMRD
33
42
56
70
94
121
157
188
223
273
328
372
417
470
544
609
687

In Duct
ARMRD
27
35
46
58
77
99
127
153
181
224
269
307
345
391
453
509
575

Approximate Voltage Drop

In Air
UNARM
23
32
42
54
71
103
129
160
195
247
305
356
408
472
563
650
756

ARMRD
26
34
46
58
79
105
136
168
203
254
314
363
414
478
564
643
740

In Ground
mV/A/m
31
19
12
7.9
4.7
2.91
1.91
1.31
1.01
0.71
0.51
0.41
0.41
0.31
0.21
0.21
0.20

In Duct
mV/A/m
31
19
12
7.9
4.7
2.89
1.89
1.29
0.99
0.69
0.49
0.39
0.39
0.29
0.19
0.19
0.18

In Air
mV/A/m
31
19
12
7.9
4.7
2.89
1.89
1.29
0.99
0.69
0.49
0.39
0.39
0.29
0.19
0.19
0.18

Nominal
conductor
area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

In Ground
In Duct
In Air

Direct in ground in trefoil touching


Single way ducts touching
Spacing 3 x cable diameter

AC Current Ratings in Amp


In Ground
ARMRD
28
36
47
59
79
102
131
157
187
229
274
312
349
394
455
509
574

In Duct
ARMRD
22
29
39
48
65
83
107
128
152
187
226
258
291
329
380
427
490

Approximate Voltage Drop

In Air
UNARM
20
29
36
47
61
89
111
137
167
212
262
306
351
406
483
558
647

ARMRD
22
29
39
49
68
89
116
143
173
218
269
312
357
411
485
553
636

In Ground
mV/A/m
27
16
10
6.8
4
2.5
1.71
1.21
0.91
0.61
0.51
0.41
0.31
0.31
0.21
0.21
0.21

Direct in ground in trefoil touching


Single way ducts touching
Spacing 3 x cable diameter

Installation Conditions considered for Current ratings


Ground Temperature
:
35C
Ambient air temperature
:
45C
Depth of laying
:
0.50m
Soil thermal Resistivity
:
1.20Cm/W
Max. permissible operating temperature at rated current:
90C
Note: for other installation conditions please refer appropriate rating factors

Installation Conditions considered for Current ratings


Ground Temperature
:
35C
Ambient air temperature
:
45C
Depth of laying
:
0.50m
Soil thermal Resistivity
:
1.20Cm/W
Max permissible operating temperature at rated current:
90C
Note: for other installation conditions please refer appropriate rating factors

The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development

The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development

22

23

In Duct
mV/A/m
27
16
10
6.8
4
2.5
1.69
1.19
0.89
0.59
0.49
0.39
0.29
0.29
0.19
0.19
0.19

In Air
mV/A/m
27
16
10
6.8
4
2.5
1.69
1.19
0.89
0.59
0.49
0.39
0.29
0.29
0.19
0.19
0.19

RATING FACTORS
Where the conditions of installation are differes from those defined
in the Current rating tables, the following rating factors may be used to
determine the data for actual installation conditions

CABLE LAID DIRECTLY IN GROUND

POWER CABLES - CURRENT RATINGS

Rating factors for variation in ground temperature

Current ratings and Voltage drop of five core cables

Ground Temperature

In Ground
In Duct
In Air

In Ground
ARMRD
28
36
47
59
79
102
131
157
187
229

In Duct
ARMRD
22
29
39
48
65
83
107
128
152
187

20C

25C

30C

35C

40C

1.00

0.95

Cross Linked Polyethelyne (XLPE) insulated

Rating Factors
AC Current Ratings in Amp

15C

Cable Type

Copper conductor, XLPE insulated armoured/unarmoured cable


Nominal
conductor
area
mm2
1.5
2.5
4
6
10
16
25
35
50
70

10C
1.20

1.16

1.13

1.08

1.03

Approximate Voltage Drop

In Air
UNARM
20
29
36
47
61
89
111
137
167
212

ARMRD
22
29
39
49
68
89
116
143
173
218

In Ground
mV/A/m
27
16
10
6.8
4
2.5
1.71
1.21
0.91
0.61

Direct in ground in trefoil touching


Single way ducts touching
Spacing 3 x cable diameter

Installation Conditions considered for Current ratings


Ground Temperature
:
35C
Ambient air temperature
:
45C
Depth of laying
:
0.50m
Soil thermal Resistivity
:
1.20Cm/W
Max permissible operating temperature at rated current:
90C
Note: for other installation conditions please refer appropriate rating factors
The data provided are for guidance only Nuhas reserve the rights to edit/modify
any or whole of the data as a part of their effort of continuous Reaserch & Development

24

In Duct
mV/A/m
27
16
10
6.8
4
2.5
1.69
1.19
0.89
0.59

In Air
mV/A/m
27
16
10
6.8
4
2.5
1.69
1.19
0.89
0.59

Rating Factors for variation in thermal resistivity of Soil


Soil Thermal Reststivity in c-m/W

Size of Cable in mm2


0.8

0.9

1.0

1.2

1.5

2.0

2.5

Up to 150

1.16

1.12

1.07

1.00

0.91

0.81

0.73

from 185 to 300

1.17

1.12

1.07

1.00

0.91

0.80

0.73

from 300 to 1000

1.17

1.12

1.07

1.00

0.91

0.80

0.73

Up to 16

1.12

1.08

1.05

1.00

0.93

0.84

0.77

from 25 to 150

1.14

1.10

1.06

1.00

0.92

0.82

0.75

from 185 to 400

1.15

1.10

1.07

1.00

0.92

0.81

0.74

Single Core Cables

Multi Core Cables

Rating factors for Depth of Laying ( to centre of the cable or Trefoil group of cable )
Depth of Laying in m

600/1000 Volt
Upto 50 mm2

from 70 to 300 mm2

400 mm2 and above

0.50

1.00

1.00

1.00

0.60

0.99

0.98

0.97

0.80

0.97

0.96

0.94

1.00

0.95

0.93

0.92

1.25

0.94

0.92

0.89

1.50

0.93

0.90

0.87

1.75

0.92

0.89

0.86

2.00

0.91

0.88

0.85

2.50

0.90

0.87

0.84

3.00 or more

0.89

0.85

0.82

25

Group Rating Factors for Circuits of three single core cables in trefoil flat touching, in horizontal formation
Spacing of Circuits

Voltage grade
600/1000 V

Touching

Spaced by

Number of circuits

Trefoil

Laid Flat

0.15 m

0.30 m

0.45 m

0.60 m

0.78

0.81

0.83

0.88

0.91

0.93

0.66

0.7

0.73

0.79

0.84

0.87

0.61

0.64

0.68

0.73

0.81

0.85

0.56

0.6

0.64

0.73

0.79

0.85

0.53

0.57

0.61

0.71

0.78

0.82

Rating factors for depth of laying (to centre of duct or trefoil group of ducts)
Depth of Laying

Group Rating Factors for Multicore cables in horizontal formation


Number of Cable group

Touching

Spaced by

600 / 1000 Volts

in m

Singlecore

Multicore

0.50

1.00

1.00

0.60

0.98

0.99

0.80

0.95

0.98

1.00

0.93

0.96

1.25

0.91

0.95

1.50

0.89

0.94

0.15 m

0.30 m

0.45 m

0.60 m

1.75

0.88

0.94

0.81

0.87

0.91

0.93

0.95

2.00

0.87

0.93

0.70

0.78

0.84

0.88

0.90

2.50

0.86

0.92

0.63

0.74

0.81

0.86

0.89

3.00

0.85

0.91

0.59

0.70

0.78

0.84

0.87

0.55

0.68

0.77

0.83

0.87

0.50

0.66

0.75

0.82

0.86

0.48

0.63

0.74

0.81

0.85

Group Rating factors for single core cables in trefoil single way ducts, horizontal formation (average value)
Spaced by
Number of circuits

Touching

0.45 m

0.60 m

0.87

0.91

0.93

0.78

0.84

0.87

0.74

0.81

0.85

0.7

0.79

0.83

0.69

0.78

0.82

CABLES INSTALLED IN DUCTS


Recommended Duct dimensions and Cable sizes
Duct Diameter in mm

Overall cable diameter

Inside diameter

Outside diameter

up to and including 65 mm

100

130

above 65 & up to and including 90 mm

125

168

Group Rating factors for multicore cables in single way ducts, horizontal formation ( average value)

Rating factors for variation in ground temperature for cables laid in ducts
Ground Temperature

10C

15C

Cable Type
Rating Factors

20C

25C

30C

35C

40C

Cross Linked Polyethelyne (XLPE) insulated


1.20

1.16

1.13

1.08

1.03

1.00

Spaced by in m

Number of

0.95

Rating Factors for variation in thermal resistivity of Soil

ducts in ground

Touching

0.9

0.30

0.45

0.60

0.93

0.95

0.96

0.83

0.88

0.91

0.93

0.79

0.85

0.89

0.92

0.75

0.83

0.88

0.91

0.73

0.82

0.87

0.90

Soil Thermal Reststivity in C-m/W

Size of Cable in mm2

CABLE INSTALLED IN AIR

0.8

0.9

1.0

1.2

1.5

2.0

2.5

Up to 150

1.10

1.07

1.04

1.00

0.94

0.86

0.80

Air temperature

from 185 to 300

1.11

1.08

1.05

1.00

0.93

0.85

0.79

Cable Type

from 300 to 1000

1.12

1.08

1.05

1.00

0.93

0.84

0.78

Rating factor

Up to 16

1.04

1.03

1.02

1.00

0.97

0.92

0.88

from 25 to 150

1.06

1.04

1.03

1.00

0.95

0.90

0.85

from 185 to 400

1.07

1.05

1.03

1.00

0.95

0.88

0.83

Single Core Cables

Rating factors for variation in ground temperature for cables laid in ducts
25C

30C

35C

45C

50C

55C

0.94

0.88

Cross Linked Polyethelyne (XLPE) insulated


1.20

1.16

1.11

Multi Core Cables

26

40C

27

1.06

1.00

SHORT CIRCUIT CURRENT CHART OF COPPER CONDUCTOR,


XLPE INSULATED 600/1000 V CABLES
SHORT CIRCUIT CURRENT RATINGS OF 600/1000 V CABLES
COPPER CONDUCTOR, XLPE INSULATION

10000.00

CALCULATION OF SHORT CIRCUIT CURRENT


 , "

MPHF
5


 


G



1000.00

XIFSF  







*TDTIPSUDLUDVSSFOU ,"
 





5  TIPSUDLUEVSBUJPO 4FD

,  DPOTUBOUGPSDPQQFS





"  DSPTTTFDUJPOBMBSFB NN
 




G  mOBMUFNQFSBUVSF $

  JOJUJBMUFNQFSBUVSF $

  SFDJQSPDBMPGSFTJTUBODFUFNQFSBUVSFDPFDJFOU GPSDPQQFS


Short circuit current


for 1 sec
in KA
0.21
0.36
0.57
0.86
1.43
2.29
3.58
5.01
7.15
10.0
13.6
17.2
21.5
26.5
34.3
42.9
57.2
71.5
90.1
114.5
143.1

S hort c irc uit Current in k A

Nominal cross sectional


area of conductor
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

100.00
1000.0
800.0
630.0
500.0
400.0
300.0
240.0
185.0
150.0
120.0
95.0

10.00

70.0
50.0
35.0
25.0
16.0

1.00

10.0
6.0
4.0
2.5
1.5

0.10

1.0
0.75
0.50

NO/TECH/SCCR/XLPE/MDPB/2010

0.01
0.01

0.1

Duration of Short Circuit in sec

28

29

10

A rea of Cros s S ec t ion in s q. mm

*TD


30

31

32

/6)"40."/--$
10#PY 1PTUBM$PEF 
3VTBZM*OEVTUSJBM&TUBUF 4VMUBOBUFPG0NBO
5FM   'BY 
&NBJMNBSLFUJOH!OVIBTPNBODPN8FCTJUFXXXOVIBTPNBODPN


".FNCFSPGUIF"M#BIKB(SPVQ

"/*40$0.1"/:
/6.,5%#+3FW
%BUF

$"#-&48*3&4

*/4536.&/5"5*0/$"#-&4

26"-*5:3&-*"#*-*5:

/6)"40."/

INTRODUCTION
Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of:

i8FBU/VIBT0NBODFBTFMFTTMZTUSJWFUP

HV, MV and LV Cables

Enamelled Copper Wires

BDIJFWFQSPEVDUFYDFMMFODFUISPVHI

Oxygen Free Continuous Cast Copper Wire Rods

Drawn Copper Conductors

505"-26"-*5:."/"(&.&/5UPQSPWJEF
UIFCFTUWBMVFUPPVSDVTUPNFST*UJTPVS
NJTTJPOUPQSPEVDFHMPCBMMZDPNQFUJUJWF
QSPEVDUTUISPVHIDPOUJOVPVT
EFWFMPQNFOUPGQSPEVDUJPODBQBCJMJUJFT 
TLJMMTFUTBOETJNVMUBOFPVTMZ
DPOUSJCVUJOHUPJOEVTUSJBMBOE
FDPOPNJDEFWFMPQNFOUPG0NBOw

Our state-of-the-art manufacturing facilities with cutting edge technology ensure that our products meet with
highest quality standards. All our products utilize only OXYGEN FREE HIGH CONDUCTIVITY
ELECTRONIC GRADE Copper produced through the Outokompu UPCAST technology, producing minimum
99.99% pure copper with oxygen content less than 5 ppm. The usage of /XYGEN&REE(IGH#ONDUCTIVITY#OPPER
ENABLESUSINACHIEVINGQUALITYEXCELLENCE
Our range of World-class HV, MV and LV Cables includes Single & Multi Core Armoured and Un-armoured
Cables, Specialty, Control, Instrumentation and also LSF, FRLS, LSOH & Custom Cables to meet the
requirements of a broad spectrum of applications ranging from 0OWER$ISTRIBUTION )NDUSTRIAL 0ETROCHEMICAL /IL
'AS !ERONAUTICAL #ONSTRUCTIONS )NSTRUMENTATION (OSPITALS (OTELS3ECURITYETC
The Cables are produced in compliance to the requirements of BS, IEC, VDE, ASTM, ICEA & UL
specifications. The #ABLESAREROUTINELYTYPETESTED by acclaimed independent international certifying agencies
confirming compliance to respective standards.
Nuhas IS COMMITTED TO DELIVER QUALITY PRODUCTS that conform to relevant International standards and 1UALITY
ASSURANCEISTHEDRIVINGFORCEBEHINDTHE#OMPANYSOPERATIONS

/UR1UALITY-ANAGEMENT3YSTEMHASBEENCERTIlEDTOCONFORMTO)3/BY"!3%# 5+
Our quality cycle encompasses raw material and consumable sourcing, in-process production controls and
certification of finished goods prior to delivery. A well-equipped in-house quality assurance facility, manned by
qualified professionals from the industry, ensures that all products delivered meet stringent quality controls
and parameters. Our state-of-the-art laboratory is equipped to test as per relevant international standards as
also to individual customer specifications.
The company endeavours to cater to the domestic, regional and global markets while maintaining the sanctity
of our pristine environment.
.EWPRODUCTDEVELOPMENT is a continuing process at Nuhas Oman LLC and we at Nuhas Oman ceaselessly
strive to achieve product excellence through TOTAL QUALITY MANAGEMENT to provide the best value to
our customers.

NUHAS OMAN QUALITY & RELIABILITY.


1

TABLE 2

TABLE 1

Instrumentation Cables - Armoured Type -2

Instrumentation Cable - Unarmoured Type - 1


Cu /PE /Osc /PVC
Reference Standards

BS 5308 Part 1

Construction

1) Oxygen Free Electronic Copper


Conductor Class 1/ 2 / 5
2) PE Insulation
3) Overall screen with Aluminium Mylar
Tape & Tinned Copper drain wire
4) PVC outer sheathing

Conductor Size

Applications

Number of pairs

mm2
1
0.50
(1/0.8)

For instrumentation purpose to


reduce crosstalk and to protect
signals from outside
electromagnetic,electrostatic and
radio frequency interference

Reference Standards
Construction

BS 5308 part 1

Applications

For instrumentation purpose to


reduce crosstalk and to protect

1) Oxygen Free Electronic Copper

signals from outside

Conductor class 1 / 2 & 5


2) PE Insulation

electromagnetic,electrostatic and

3) Overall screen with Aluminium

radio frequency interference


alongwith protection from

Mylar tape & Tinned Copper drain wire

mechanical damage

4) PVC Bedding
Technical Data

Please refer table A on page No.11

Voltage

300/500 V

Thickness of Sheath

Approx Overall Diameter

mm

mm

0.8

6.5

2(Quad)

0.8

7.3

1.1

11.9

10

1.2

15.3

0.8

7.2

0.50

2(Quad)

0.8

8.1

(16/0.2)

1.1

13.4

10

1.2

17.5

0.8

7.6

1.0

2(Quad)

0.8

8.6

(1/1.13)

1.2

14.5

10

1.2

18.7

0.8

8.5

1.5

2(Quad)

0.9

9.9

(7/0.53)

1.2

16.7

10

1.3

22.0

Note : The above cables can also be manufactured & supplied with LSF on request.

Cu / PE / Osc / SWA / PVC

5) Galvanized steel wire Armour


6) PVC Outer sheathing

Conductor Size

Number of pairs

mm

Technical Data

Please refer Table A on page No.11

Voltage

300/500 V

Thickness of

Size of

Thickness of

Approx Overall

Bedding

Armour wire

Sheath

Diameter

mm

mm

mm

mm

0.8

0.9

1.3

11.0

0.50

2(Quad)

0.8

0.9

1.3

11.8

(1/0.8)

1.1

0.9

1.4

16.5

10

1.2

1.25

1.6

21.1

0.8

0.9

1.3

11.7

0.50

2(Quad)

0.8

0.9

1.3

12.6

(16/0.2)

1.1

0.9

1.5

18.2

10

1.2

1.25

1.6

23.3

0.8

0.9

1.3

12.1

1.0

2(Quad)

0.8

0.9

1.4

13.3

(1/1.13)

1.2

1.25

1.5

20.0

10

1.2

1.25

1.7

24.7

0.8

0.9

1.4

13.2

1.5

2(Quad)

0.9

0.9

1.4

14.6

(7/0.53)

1.2

1.25

1.6

22.4

10

1.3

1.6

1.8

28.8

Note : The above cables can also be manufactured & supplied with LSF on request.

TABLE 4
TABLE 3

Instrumentation cables - Armoured Type -2

Instrumentation cables Unarmoured Type -1

Cu /PE /Isc /Osc /SWA /PVC

Cu/PE/ISc/OSc/PVC
Reference Standards
Construction

Applications

BS 5308 Part 1

For instrumentation purpose to


reduce crosstalk and to protect

1) Oxygen Free Electronic Copper

BS 5308 Part 1

Construction

1) Oxygen Free Electronic Copper


Conductor class 1/2/5
2) PE Insulation
3) Individual pair screen with Aluminium
Mylar tape & Tinned Copper drain wire
4) Overall screened with Aluminium Mylar
tape & Tinned Copper drain wire
5) PVC Bedding
6) Galvanized steel wire Armour
7) PVC Outer sheathing

signals from outside

Conductor Class 2 & 5

electromagnetic,electrostatic and

2) PE Insulation

radio frequency interference

3) Individual pair screened with Aluminium


Mylar tape & Tinned Copper drain wire
4) Overall screen with Aluminium mylar

Conductor Size

Tape & Tinned Copper drain wire

Technical Data

Please refer Table A on page No.11

5) PVC outer sheathing

Voltage

300/500 V

Number of pairs

Thickness of Sheath

Approx Overall Diameter

mm

mm

0.9

10.6

1.2

13.8

10

1.2

18.6

1.1

12.3

1.2

15.5

10

1.3

21.5

1.1

13.1

1.2

15.5

10

1.3

23.0

1.2

15.0

mm

0.50
(1/0.8)
0.50
(16/0.2)
1.0
(1/1.13)
1.5
(7/0.53)

1.3

19.1

10

1.5

26.9

Note : The above cables can also be manufactured & supplied with LSF on request.

Applications

Reference Standards

Conductor Size

Number of pairs

0.50
(16/0.2)
1.0
(1/1.13)
1.5
(7/0.53)

reduce crosstalk and to protect


signals from outside
electromagnetic,electrostatic and
radio frequency interference
alongwith protection from
mechanical damage

Technical Data
Voltage

Thickness of

Size of

Thickness of

Approx Overall

Bedding

Armour wire

Sheath

Diameter

mm

mm

mm

mm

0.8

0.9

1.3

11.8

1.1

0.9

1.4

16.5

10

1.2

1.25

1.6

21.1

1.1

0.9

1.5

17.1

1.2

1.25

1.6

21.3

10

1.3

1.6

1.8

28.3

1.1

0.9

1.5

17.9

1.2

1.25

1.6

22.3

10

1.3

1.6

1.8

29.8

1.2

1.25

1.6

20.8

1.3

1.6

1.7

25.8

10

1.5

1.6

1.9

33.9

Note : The above cables can also be manufactured & supplied with LSF on request.

Please refer Table A on page No.11


300/500 V

mm

0.50
(1/0.8)

For instrumentation purpose to

TABLE 6
TABLE 5

Instrumentation cables - Armoured Type 2

Instrumentation cables Unarmoured Type - 1

Cu /PVC /Osc /SWA /PVC

Cu /PVC /Osc /PVC


Reference Standards

BS 5308 Part 2

Construction

1) Oxygen Free Electronic Copper

Applications

For instrumentation purpose to

BS 5308 Part 2

Construction

1) Oxygen Free Electronic Copper

2) PVC Insulation

2) PVC Insulation

electromagnetic,electrostatic and

electromagnetic,electrostatic and

3) Overall screen with Aluminium Myla

radio frequency interference

Conductor Size

Number of pairs

Technical Data

Please refer Table B on page No.11

Voltage

300/500 V

Thickness of Sheath

Nominal Overall Diameter

mm

mm

0.8

7.2

0.50

2 (Quad)

0.8

8.1

(16/0.2)

1.1

13.4

10

1.2

17.5

0.8

7.5

0.75

2 (Quad)

0.8

8.5

(24/0.2)

1.2

14.6

10

1.3

19.0

0.8

8.5

1.5

2 (Quad)

0.9

9.9

(7/0.53)

1.2

16.7

10

1.3

22.0

mm

Note : The above cables can also be manufactured & supplied with LSF on request.

alongwith protection from

tape and Tinned Copper drain wire


4) PVC Bedding

Tape & Tinned Copper drain wire


4) PVC outer sheathing

signals from outside

signals from outside


radio frequency interference

3) Overall screen with Aluminium Mylar

mechanical damage

5) Galvanized steel wire Armour


6) PVC Outer sheathing

Conductor Size

Number of pairs

mm

0.50
(16/0.2)

0.75
(24/0.2)

1.5
(7/0.53)

Technical Data

Please refer Table B on page No.11

Voltage

300/500 V

Thickness of

Size of

Thickness of

Approx Overall

Bedding

Armour wire

Sheath

Diameter

mm

mm

mm

mm

0.8

0.9

1.3

11.7

2 (Quad)

0.8

0.9

1.3

12.6

1.1

0.9

1.5

18.2

10

1.2

1.25

1.6

23.2

0.8

0.9

1.3

12.0

2 (Quad)

0.8

0.9

1.4

13.2

1.2

1.25

1.5

20.1

10

1.3

1.6

1.7

25.7

0.8

0.9

1.4

13.2

2 (Quad)

0.9

0.9

1.4

14.6

1.2

1.25

1.6

22.5

10

1.3

1.6

1.8

28.8

Note : The above cables can also be manufactured & supplied with LSF on request.

For instrumentation purpose to


reduce crosstalk and to protect

Conductor class 2 & 5

reduce crosstalk and to protect

Conductor Class 2 & 5

Applications

Reference Standards

TABLE 7

Instrumentation cables - Unarmoured Type 1


Cu /PVC /Isc /Osc /PVC
Reference Standards

Applications

BS 5308 Part 2

Construction

For instrumentation purpose to


reduce crosstalk and to protect
signals from outside
electromagnetic,electrostatic and
radio frequency interference

1) Oxygen Free Electronic Copper


Conductor Class 2 & 5
2) PVC Insulation
3) Individual pair screened with Aluminium
4) Overall screened with Aluminium
Mylar Tape and Tinned Copper drain wire Technical Data
5) PVC outer sheathing
Voltage

TABLE 9

Please refer Table B on page No.11


300/500 V

Instrumentation cables - Unarmoured Type 1


Cu /PVC /Osc /PVC

Conductor Size
mm

Number of pairs

Thickness of Sheath
mm

Approx Overall Diameter


mm

0.50

1.1

12.3

(16/0.2)

1.2

15.5

10

1.3

21.5

2) PVC Insulation

1.1

13.1

3) Overall screen with Aluminium mylar

1.2

16.6

10

1.3

23.1

1.2

15.0

1.3

19.1

10

1.5

26.9

0.75
(24/0.2)
1.5
(7/0.53)

Applications

Reference Standards

BS 5308 Part 2

Construction

1) Oxygen Free Electronic Copper

Conductor Size

Number of cores

300/500 V

Thickness of Sheath

Approx Overall Diameter

mm

mm

0.8

7.2

0.8

7.5

0.50

0.8

8.1

(16/0.2)

0.9

9.5

10

1.1

12.2

20

1.2

15.2

Applications

1) Oxygen Free Electronic Copper


Conductor class 2 & 5
2) PVC Insulation
3) Individual pair screen with Aluminium
Mylar tape and Tinned Copper drain wire
4) Overall screened with Aluminium Mylar
tape and Tinned Copper wire
5) PVC Bedding
Technical Data
6) Galvanized steel wire Armour
Voltage
7) PVC Outer sheathing
Number of pairs

For instrumentation purpose to


reduce crosstalk and to protect
signals from outside
electromagnetic,electrostatic and
radio frequency interference
alongwith protection from
mechanical damage

0.8

7.5

0.8

7.9

0.75

0.8

8.5

(24/0.2)

0.9

10.1

10

1.1

13.0

20

1.2

16.4

0.8

8.5

0.9

9.1

1.5

0.9

9.9

(7/0.53)

1.1

12.0

Please refer Table B on page No.11


300/500 V

Thickness of

Size of

Thickness of

Approx Overall

Bedding

Armour wire

Sheath

Diameter

10

1.2

15.0

20

1.3

19.1

mm

mm

mm

mm

1.1

0.9

1.5

17.1

1.2

1.25

1.6

21.3

10

1.3

1.6

1.8

28.3

mm

(7/0.53)

Voltage

Construction

1.5

Please refer Table B on page No.11

Instrumentation cables - Armoured Type 2


BS 5308 Part 2

(24/0.2)

Technical Data

TABLE 8

Reference Standards

0.75

radio frequency interference

Tape and Tinned Copper drain wire


4) PVC outer sheathing

Cu /PVC /Isc /Osc /SWA /PVC

(16/0.2)

signals from outside


electromagnetic,electrostatic and

mm2

0.50

reduce crosstalk and to protect

Conductor Class 2 & 5

Note : The above cables can also be manufactured & supplied with LSF on request.

Conductor Size

For instrumentation purpose to

1.1

0.9

1.5

17.9

1.2

1.25

1.6

22.4

10

1.3

1.6

1.8

29.9

1.2

1.25

1.6

20.8

1.3

1.6

1.7

25.8

10

1.5

1.6

1.9

33.9

Note : The above cables can also be manufactured & supplied with LSF on request.

Note : The above cables can also be manufactured & supplied with LSF on request.
8

Instrumentation Cables - Technical data


TABLE A
(PROPERTIES AS PER BS 5308 PART 1)
Electrical Properties

0.5 mm

Instrumentation cables - Armoured Type 2

(1/0.8 mm)
Maximum Mutual Capacitance
75

75

75

85

b) Cables with only collective screens

pF/m

75

75

75

85

reduce crosstalk and to protect

(except one-pair and two-pair)

signals from outside

c) One-pair and two-pair cables collectively

pF/m

115

115

115

120

2) PVC Insulation

electromagnetic, electrostatic and

screened and all cables with individual pair

3) Overall screen with Aluminium

radio frequency interference

screens

alongwith protection from

L/R ratio (max)

H/ohm

25

25

25

40

mechanical damage

Max. DC conductor Resistance at 20C

ohm/km

36.8

39.7

18.4

12.3

a) Core to core/screen/armour for 1 km

b) Screen to screen for 1 km

1) Oxygen Free Electronic Copper

Mylar tape and Tinned copper drain wire


4) PVC Bedding
5) Galvanized steel wire Armour

Technical Data Please refer Table B on page No.11

6) PVC Outer sheathing

Voltage

300/500 V

Nom. Insulation thickness


(mm)

Maximum core diameter


(mm)

Diameter

0.5 (1/0.8)

0.50

1.90

mm

mm

0.5 (16/0.2)

0.60

2.35

0.9

1.3

11.7

1.0 (1/1.13)

0.60

2.45

0.8

0.9

1.3

12.0

1.5 (7/0.53)

0.60

3.00

0.8

0.9

1.3

12.6

Number of

Thickness of

Size of

Thickness of

Approx Overall

Size

Cores

Bedding

Armour wire

Sheath

mm

mm

0.8

3
4

mm

1.5
(7/0.53)

Minimum Insulation Resistance

Conductor nominal area


(mm)

Conductor

(24/0.2)

1.5 mm

pF/m

Applications

Conductor class 2 & 5

0.75

1.0 mm

a) Cables without screens

BS 5308 Part 2

Construction

0.5 mm

(16/0.2 mm) (1/1.13 mm) (7/0.53 mm)

For instrumentation purpose to

Reference Standards

(16/0.2)

Cross sectional area of conductor

TABLE 10
Cu /PVC /Osc /SWA /PVC

0.50

Unit

0.9

0.90

1.4

14.2

10

1.1

0.9

1.5

17.0

20

1.2

1.25

1.6

19.9

0.8

0.9

1.3

12.0

0.8

0.9

1.3

12.4

0.8

0.9

1.4

13.2

TABLE B
(PROPERTIES AS PER BS 5308 PART 2)
Electrical Properties

Unit

Cross sectional area of conductor


0.5 mm

0.75 mm

1.5 mm

(16/0.2 mm) (24/0.2 mm) (7/0.53 mm)

0.9

0.90

1.4

14.8

10

1.1

0.9

1.5

17.8

Maximum Mutual Capacitance

20

1.2

1.3

1.6

21.9

a) Mutual capacitance of pairs or adjacent cores

0.8

0.90

1.4

13.2

b) Between any core and core screen


L/R ratio (max)

0.9

0.90

1.4

13.8

0.9

0.90

1.4

14.6

Max. DC conductor Resistance at 20C

pF/m

250

250

250

pF/m

450

450

450

H/ohm

25

25

40

ohm/km

39.7

26.5

12.3

1.1

0.9

1.4

16.9

Minimum Insulation Resistance

10

1.2

1.25

1.6

20.8

a) Core to core/screen/armour for 1 km

25

25

25

25.9

b) Screen to screen for 1 km

20

1.3

1.6

Note : The above cables can also be manufactured & supplied with LSF on request.

10

1.7

Conductor nominal area


(mm)

Nom. Insulation thickness


(mm)

Maximum core diameter


(mm)

0.5 (16/0.2)

0.60

2.35

0.75 (24/0.2)

0.60

2.45

1.5 (7/0.53)

0.60

3.00

11

12

13

/6)"40."/--$
10#PY 1PTUBM$PEF 
3VTBZM*OEVTUSJBM&TUBUF 4VMUBOBUFPG0NBO
5FM   'BY 
&NBJMNBSLFUJOH!OVIBTPNBODPN8FCTJUFXXXOVIBTPNBODPN


".FNCFSPGUIF"M#BIKB(SPVQ

"/*40$0.1"/:
/6.,5%#+3FW
%BUF

$"#-&48*3&4

.&%*6.70-5"(&$"#-&4

26"-*5:3&-*"#*-*5:

/6)"40."/

INDEX PAGE
Description of Cables
Table No.

i8FBU/VIBT0NBODFBTFMFTTMZTUSJWFUP
BDIJFWFQSPEVDUFYDFMMFODFUISPVHI
505"-26"-*5:."/"(&.&/5UPQSPWJEF
UIFCFTUWBMVFUPPVSDVTUPNFST*UJTPVS
NJTTJPOUPQSPEVDFHMPCBMMZDPNQFUJUJWF
QSPEVDUTUISPVHIDPOUJOVPVT
EFWFMPQNFOUPGQSPEVDUJPODBQBCJMJUJFT 
TLJMMTFUTBOETJNVMUBOFPVTMZ
DPOUSJCVUJOHUPJOEVTUSJBMBOE
FDPOPNJDEFWFMPQNFOUPG0NBOw

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51 to 62

Page No.
Company Introduction
1
3.6/6(7.2) kV, Single Core Copper conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
2
6/10(12) kV ,Single Core Copper conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
3
8.7/15(17.5) kV ,Single Core Copper conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
4
12/20(24) kV ,Single Core Copper conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
5
18/30(36) kV ,Single Core Copper conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
6
3.6/6(7.2) kV,Single Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
7
6/10(12) kV,Single Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
8
8.7/15(17.5) kV,Single Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
9
12/20(24) kV,Single Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
10
18/30(36) kV,Single Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
11
3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
12
6/10(12) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
13
8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
14
12/20(24) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
15
18/30(36) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
16
3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
17
6/10(12) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
18
8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
19
12/20(24) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
20
18/30(36) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
21
3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
22
6/10(12) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
23
8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
24
12/20(24) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
25
18/30(36) kV, Three Core Copper conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
26
3.6/6(7.2) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
27
6/10(12) kV ,Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
28
8.7/15(17.5) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
29
12/20(24) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
30
18/30(36) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Aluminium Round Wire Armoured cable
31
3.6/6(7.2) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
32
6/10(12) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
33
8.7/15(17.5) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
34
12/20(24) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
35
18/30(36) kV, Single Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
36
3.6/6(7.2) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
37
6/10(12) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
38
8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
39
12/20(24) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
40
18/30(36) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Round Wire Armoured cable
41
3.6/6(7.2) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
42
6/10(12) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
43
8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
44
12/20(24) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
45
18/30(36) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Un-Armoured cable
46
3.6/6(7.2) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
47
6/10(12) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
48
8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
49
12/20(24) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
50
18/30(36) kV, Three Core Aluminium conductor XLPE insulated IEC: 60502-2 Steel Tape Armoured cable
51
Rating factors & general technical information
52 to 54

Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of:

HV, MV and LV Cables

Enamelled Copper Wires

Oxygen Free Continuous Cast Copper Wire Rods

Drawn Copper Conductors

Our state-of-the-art manufacturing facilities with cutting edge technology ensure that our products meet with

highest quality standards. All our products utilize only OXYGEN FREE HIGH CONDUCTIVITY

ELECTRONIC GRADE Copper produced through the Outokompu UPCAST technology, producing minimum

99.99% pure copper with oxygen content less than 5 ppm. The usage of /XYGEN&REE(IGH#ONDUCTIVITY#OPPER

ENABLESUSINACHIEVINGQUALITYEXCELLENCE

Our range of World-class HV, MV and LV Cables includes Single & Multi Core Armoured and Un-armoured

Cables, Specialty, Control, Instrumentation and also LSF, FRLS, LSOH & Custom Cables to meet the

requirements of a broad spectrum of applications ranging from 0OWER$ISTRIBUTION )NDUSTRIAL 0ETROCHEMICAL /IL

'AS !ERONAUTICAL #ONSTRUCTIONS )NSTRUMENTATION (OSPITALS (OTELS3ECURITYETC

The Cables are produced in compliance to the requirements of BS, IEC, VDE, ASTM, ICEA & UL

specifications. The #ABLESAREROUTINELYTYPETESTED by acclaimed independent international certifying agencies

confirming compliance to respective standards.

Nuhas IS COMMITTED TO DELIVER QUALITY PRODUCTS that conform to relevant International standards and 1UALITY

ASSURANCEISTHEDRIVINGFORCEBEHINDTHE#OMPANYSOPERATIONS

/UR1UALITY-ANAGEMENT3YSTEMHASBEENCERTIlEDTOCONFORMTO)3/BY"!3%# 5+

Our quality cycle encompasses raw material and consumable sourcing, in-process production controls and

certification of finished goods prior to delivery. A well-equipped in-house quality assurance facility, manned by

qualified professionals from the industry, ensures that all products delivered meet stringent quality controls

and parameters. Our state-of-the-art laboratory is equipped to test as per relevant international standards as

also to individual customer specifications.

The company endeavours to cater to the domestic, regional and global markets while maintaining the sanctity

of our pristine environment.

.EWPRODUCTDEVELOPMENT is a continuing process at Nuhas Oman LLC and we at Nuhas Oman ceaselessly

strive to achieve product excellence through TOTAL QUALITY MANAGEMENT to provide the best value to

our customers.

1
2

42.9

57.2

71.5

607
487
813

90.1

649
530
909

114.5

692
564
997

800
34.14
7100
2.8
2.5
2.8
55.2
9328
400
828
0.0221
0.0281
0.073
0.087
0.71
0.81

143.1

734
589
1075

1000
38.2
8900
2.8
2.5
2.9
59.6
11384
300
894
0.0176
0.0224
0.073
0.082
0.75
0.85

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

34.3

556
453
734

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

495
427
647

2. Air temperature 40C

21.5

444
401
568

1 Ground temperature 35C

17.2

389
350
481

4. Depth of laying 800 mm

13.6

350
321
428

630
30.0
5548
2.8
2.5
2.6
50.5
7500
500
757
0.0283
0.0360
0.074
0.095
0.68
0.77

Assumption:

10.0

307
291
376

500
26.3
4272
2.8
2.5
2.5
46.5
6015
500
697
0.0366
0.0466
0.075
0.108
0.65
0.74

7.15

274
260
328

240
300
400
18.4
20.6
23.3
2074
2602
3327
2.8
2.8
2.8
2.0
2.0
2.0
2.2
2.3
2.4
36.6
39.2
42.1
3247
3900
4766
500
500
500
549
588
632
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.080 0.078
0.076
0.178 0.150
0.125
0.49
0.54
0.61
0.55
0.61
0.69

kA

230
222
271

120
150
185
12.9
14.6
16.0
1027
1267 1578
2.8
2.8
2.8
2.0
2.0
2.0
2.0
2.0
2.1
30.6
32.3
33.9
1931
2243 2628
500
500
500
459
485
509
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.086 0.084 0.082
0.334 0.276 0.225
0.37
0.40
0.44
0.42
0.45
0.50
188
188
219

95
11.4
814
2.8
2.0
1.9
28.8
1634
500
432
0.193
0.246
0.089
0.418
0.34
0.38
A
A
A

70
9.7
586
2.8
2.0
1.9
27.1
1335
500
406
0.268
0.342
0.092
0.573
0.30
0.34

50
8.1
408
2.8
2.0
1.8
25.2
1079
500
378
0.387
0.494
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

NUHAS OMAN QUALITY & RELIABILITY.

Technical Data for 3.6/6(7.2) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 1

INTRODUCTION

3
4

42.9

57.2

71.5

607
487
813

90.1

649
530
909

114.5

692
564
997

800
34.14
7100
3.4
2.5
2.8
57.0
9522
400
855
0.0221
0.0281
0.075
0.089
0.63
1.20

143.1

734
589
1075

1000
38.2
8900
3.4
2.5
3
61.7
11620
300
925
0.0176
0.0224
0.074
0.083
0.70
1.32

42.9

71.5

90.1

649
530
909

114.5

692
564
997

800
34.14
7100
4.5
2.5
2.9
59.6
9810
400
893
0.0221
0.0281
0.078
0.091
0.51
1.39

143.1

734
589
1075

1000
38.2
8900
4.5
2.5
3.1
64.1
11914
300
962
0.0176
0.0224
0.077
0.085
0.56
1.53

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice

57.2

607
487
813

for any other condition(s) please refer to the appropriate table for recommended installation data.

34.3

556
453
734

4. Depth of laying 800 mm

26.5

495
427
647

3. Thermal resistivity of soil 1.2C/m/W

21.5

444
401
568

2. Air temperature 40C

17.2

389
350
481

1 Ground temperature 35C

13.6

350
321
428

630
30.0
5548
4.5
2.5
2.8
55.0
7972
500
826
0.0283
0.0360
0.080
0.100
0.46
1.25

Assumption:

10.0

307
291
376

500
26.3
4272
4.5
2.5
2.6
50.8
6419
500
761
0.0366
0.0466
0.082
0.113
0.42
1.14

7.15

274
260
328

240
300
400
18.4
20.6
23.3
2074
2602
3327
4.5
4.5
4.5
2.0
2.0
2.5
2.3
2.4
2.5
41.0
43.4
47.5
3582
4244
5280
500
500
500
615
652
713
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.090 0.087
0.084
0.183 0.155
0.130
0.31
0.34
0.38
0.85
0.92
1.04

kA

230
222
271

120
150
185
12.9
14.6
16.0
1027
1267 1578
4.5
4.5
4.5
2.0
2.0
2.0
2.1
2.2
2.2
34.9
36.9
38.3
2212
2563 2943
500
500
500
523
554
575
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.099 0.096 0.093
0.338 0.280 0.229
0.24
0.26
0.28
0.65
0.71
0.77
188
188
219

95
11.4
814
4.5
2.0
2.1
33.4
1925
500
500
0.193
0.246
0.102
0.421
0.22
0.60
A
A
A

70
9.7
586
4.5
2.0
2
31.4
1599
500
471
0.268
0.342
0.107
0.576
0.20
0.54

50
8.1
408
4.5
2.0
1.9
29.5
1321
500
442
0.387
0.494
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 3

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

34.3

556
453
734

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

495
427
647

2. Air temperature 40C

21.5

444
401
568

4. Depth of laying 800 mm

17.2

389
350
481

1 Ground temperature 35C

13.6

350
321
428

630
30.0
5548
3.4
2.5
2.7
52.6
7716
500
789
0.0283
0.0360
0.077
0.097
0.57
1.08

Assumption:

10.0

307
291
376

500
26.3
4272
3.4
2.5
2.6
48.5
6205
500
728
0.0366
0.0466
0.079
0.110
0.52
0.97

7.15

274
260
328

240
300
400
18.4
20.6
23.3
2074
2602
3327
3.4
3.4
3.4
2.0
2.0
2.0
2.2
2.3
2.4
38.6
41.0
44.1
3390
4041
4927
500
500
500
578
615
661
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.085 0.083
0.080
0.181 0.152
0.128
0.38
0.42
0.47
0.72
0.79
0.89

kA

230
222
271

120
150
185
12.9
14.6
16.0
1027
1267 1578
3.4
3.4
3.4
2.0
2.0
2.0
2.0
2.1
2.2
32.5
34.4
36.0
2046
2380 2771
500
500
500
487
516
540
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.093 0.090 0.088
0.336 0.278 0.227
0.29
0.32
0.34
0.55
0.60
0.65

188
188
219

95
11.4
814
3.4
2.0
2
30.9
1766
500
464
0.193
0.246
0.096
0.420
0.27
0.50

A
A
A

70
9.7
586
3.4
2.0
1.9
28.9
1440
500
433
0.268
0.342
0.100
0.574
0.24
0.45

50
8.1
408
3.4
2.0
1.9
27.3
1191
500
409
0.387
0.494
0.105
0.825
0.21
0.40

mm2
mm
g/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 2

5
6

42.9

71.5

90.1

649
521
937

114.5

692
572
997

800
34.1
7100
5.5
2.5
3
61.8
10071
400
927
0.0221
0.0281
0.081
0.094
0.43
1.61

143.1

734
589
1075

1000
38.2
8900
5.5
2.5
3.2
66.4
12209
300
997
0.0176
0.0224
0.080
0.088
0.47
1.77

42.9

71.5

90.1

649
521
908

114.5

692
572
1037

800
34.1
7100
8.0
2.5
3.2
67.4
10763
400
1011
0.0221
0.0281
0.088
0.100
0.32
1.80

143.1

734
598
1150

1000
38.2
8900
8.0
2.5
3.3
71.7
12895
300
1076
0.0176
0.0224
0.086
0.094
0.35
1.96

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

57.2

598
487
788

for any other condition(s) please refer to the appropriate table for recommended installation data.

34.3

547
453
683

4. Depth of laying 800 mm

26.5

487
419
595

3. Thermal resistivity of soil 1.2C/m/W

21.5

436
385
523

2. Air temperature 40C

17.2

385
342
443

1 Ground temperature 35C

13.6

350
316
390

630
30.0
5548
8.0
2.5
3
62.7
8834
500
940
0.0283
0.0360
0.091
0.109
0.29
1.64

Assumption:

10.0

307
291
342

500
26.3
4272
8.0
2.5
2.9
58.7
7266
500
881
0.0366
0.0466
0.094
0.122
0.26
1.50

7.15

274
256
290

240
300
400
18.4
20.6
23.3
2074
2602
3327
8.0
8.0
8.0
2.0
2.5
2.5
2.6
2.7
2.8
48.8
52.4
55.3
4270
5131
6069
500
500
500
733
786
830
0.0754 0.0601 0.0470
0.0960 0.0766 0.0599
0.104 0.101
0.097
0.191 0.163
0.139
0.20
0.22
0.24
1.15
1.24
1.38

kA

230
222
241

120
150
185
12.9
14.6
16.0
1027
1267 1578
8.0
8.0
8.0
2.0
2.0
2.0
2.4
2.4
2.5
42.7
44.6
46.2
2817
3175 3594
500
500
500
641
669
692
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.116 0.112 0.109
0.343 0.286 0.236
0.16
0.17
0.19
0.91
0.98
1.05
188
180
197

95
11.4
814
8.0
2.0
2.3
41.0
2490
500
615
0.193
0.246
0.121
0.426
0.15
0.85
A
A
A

70
9.7
586
8.0
2.0
2.3
39.3
2156
500
589
0.268
0.342
0.127
0.579
0.14
0.77

50
8.1
408
8.0
2.0
2.2
37.4
1860
500
562
0.387
0.494
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 5

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

57.2

598
487
822

for any other condition(s) please refer to the appropriate table for recommended installation data.

34.3

547
453
726

4. Depth of laying 800 mm

26.5

487
419
638

3. Thermal resistivity of soil 1.2C/m/W

21.5

436
385
568

2. Air temperature 40C

17.2

385
342
489

1 Ground temperature 35C

13.6

350
316
428

630
30.0
5548
5.5
2.5
2.9
57.3
8216
500
859
0.0283
0.0360
0.084
0.103
0.39
1.46

Assumption:

10.0

307
291
385

500
26.3
4272
5.5
2.5
2.7
53.1
6659
500
797
0.0366
0.0466
0.086
0.116
0.35
1.33

7.15

274
260
333

240
300
400
18.4
20.6
23.3
2074
2602
3327
5.5
5.5
5.5
2.0
2.0
2.5
2.4
2.5
2.6
43.2
45.8
49.7
3768
4450
5495
500
500
500
649
687
746
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.094 0.092
0.088
0.185 0.157
0.133
0.26
0.29
0.32
1.00
1.08
1.21

kA

230
222
279

120
150
185
12.9
14.6
16.0
1027
1267 1578
5.5
5.5
5.5
2.0
2.0
2.0
2.2
2.3
2.3
37.2
39.2
40.6
2383
2733 3118
500
500
500
559
588
608
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90

188
180
227

95
11.4
814
5.5
2.0
2.1
35.4
2064
500
531
0.193
0.246
0.108
0.423
0.19
0.72

A
A
A

70
9.7
586
5.5
2.0
2.1
33.7
1747
500
505
0.268
0.342
0.113
0.577
0.17
0.65

50
8.1
408
5.5
2.0
2
31.8
1469
500
478
0.387
0.494
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 4

7
8

42.9

71.5

90.1

709
641
970

114.5

786
709
1110

800
34.14
7100
2.8
2.6
49.8
8464
400
996
0.0221
0.0281
0.073
0.087
0.71
0.81

143.1

854
778
1224

1000
38.2
8900
2.8
2.8
54.4
10468
300
1088
0.0176
0.0224
0.073
0.082
0.75
0.85

42.9

57.2

71.5

641
581
822

90.1

709
641
970

114.5

786
709
1110

800
34.14
7100
3.4
2.7
51.8
8649
400
1036
0.0221
0.0281
0.075
0.089
0.63
1.20

143.1

854
778
1224

1000
38.2
8900
3.4
2.8
56.3
10643
300
1125
0.0176
0.0224
0.074
0.083
0.70
1.32

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

34.3

581
521
734

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

513
478
647

2. Air temperature 40

21.5

453
431
560

4. Depth of laying 800 mm

17.2

393
376
472

1 Ground temperature 35C

13.6

350
342
410

630
30.0
5548
3.4
2.5
47.2
6897
500
944
0.0283
0.0360
0.077
0.097
0.57
1.08

Assumption:

10.0

307
307
363

500
26.3
4272
3.4
2.4
43.1
5457
500
862
0.0366
0.0466
0.079
0.110
0.52
0.97

7.15

274
274
314

240
300
400
18.4
20.6
23.3
2074
2602
3327
3.4
3.4
3.4
2.1
2.2
2.3
34.4
36.8
39.9
2926
3544
4388
500
500
500
687
736
797
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.085 0.083
0.080
0.181 0.152
0.128
0.38
0.42
0.47
0.72
0.79
0.89

kA

230
230
249

120
150
185
12.9
14.6
16.0
1027
1267 1578
3.4
3.4
3.4
1.9
2.0
2
28.3
30.2
31.6
1666
1973 2328
500
500
500
565
604
631
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.093 0.090 0.088
0.336 0.278 0.227
0.29
0.32
0.34
0.55
0.60
0.65
188
192
206

95
11.4
814
3.4
1.9
26.7
1406
500
534
0.193
0.246
0.096
0.420
0.27
0.50
A
A
A

70
9.7
586
3.4
1.8
24.7
1108
500
494
0.268
0.342
0.100
0.574
0.24
0.45

50
8.1
408
3.4
1.7
22.9
871
500
457
0.387
0.494
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 7

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

57.2

641
581
822

for any other condition(s) please refer to the appropriate table for recommended installation data.

34.3

581
521
734

4. Depth of laying 800 mm

26.5

513
478
647

3. Thermal resistivity of soil 1.2C/m/W

21.5

453
431
560

2. Air temperature 40C

17.2

393
376
472

1 Ground temperature 35C

13.6

350
342
410

630
30.0
5548
2.8
2.5
45.3
6740
500
905
0.0283
0.0360
0.074
0.095
0.68
0.77

Assumption:

10.0

307
307
363

500
26.3
4272
2.8
2.3
41.1
5303
500
822
0.0366
0.0466
0.075
0.108
0.65
0.74

7.15

274
274
314

240
300
400
18.4
20.6
23.3
2074
2602
3327
2.8
2.8
2.8
2.0
2.1
2.2
32.2
34.8
37.7
2795
3412
4236
500
500
500
644
695
754
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.080 0.078
0.076
0.178 0.150
0.125
0.49
0.54
0.61
0.55
0.61
0.69

kA

230
230
249

120
150
185
12.9
14.6
16.0
1027
1267 1578
2.8
2.8
2.8
1.8
1.9
2.0
26.2
28.1
29.7
1564
1864 2228
500
500
500
524
563
595
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.086 0.084 0.082
0.334 0.276 0.225
0.37
0.40
0.44
0.42
0.45
0.50

188
192
206

95
11.4
814
2.8
1.8
24.6
1304
500
492
0.193
0.246
0.089
0.418
0.34
0.38

A
A
A

70
9.7
586
2.8
1.7
22.7
1019
500
453
0.268
0.342
0.092
0.573
0.30
0.34

50
8.1
408
2.8
1.7
21.0
798
500
420
0.387
0.494
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 6

9
10

42.9

57.2

71.5

641
581
822

90.1

709
641
970

114.5

786
709
1110

800
34.14
7100
4.5
2.8
54.4
8895
400
1087
0.0221
0.0281
0.078
0.091
0.51
1.39

143.1

854
778
1224

1000
38.2
8900
4.5
2.9
58.7
10894
300
1174
0.0176
0.0224
0.077
0.085
0.56
1.53

42.9

57.2

71.5

649
598
857

90.1

727
666
988

114.5

795
727
1119

800
34.1
7100
5.5
2.8
56.4
9092
400
1128
0.0221
0.0281
0.081
0.094
0.43
1.61

143.1

863
786
1241

1000
38.2
8900
5.5
3.0
61.0
11149
300
1221
0.0176
0.0224
0.080
0.088
0.47
1.77

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

34.3

589
539
743

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

513
487
647

2. Air temperature 40C

21.5

453
444
568

1 Ground temperature 35C

17.2

393
380
481

4. Depth of laying 800 mm

13.6

350
346
424

630
30.0
5548
5.5
2.7
51.9
7316
500
1038
0.0283
0.0360
0.084
0.103
0.39
1.46

Assumption:

10.0

307
307
371

500
26.3
4272
5.5
2.5
47.7
5831
500
954
0.0366
0.0466
0.086
0.116
0.35
1.33

7.15

274
274
314

240
300
400
18.4
20.6
23.3
2074
2602
3327
5.5
5.5
5.5
2.3
2.3
2.4
39.0
41.4
44.3
3240
3868
4726
500
500
500
781
828
887
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.094 0.092
0.088
0.185 0.157
0.133
0.26
0.29
0.32
1.00
1.08
1.21

kA

230
230
262

120
150
185
12.9
14.6
16.0
1027
1267 1578
5.5
5.5
5.5
2.1
2.1
2.2
33.0
34.8
36.4
1937
2245 2627
500
500
500
661
695
727
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90
188
192
214

95
11.4
814
5.5
2.0
31.2
1644
500
624
0.193
0.246
0.108
0.423
0.19
0.72
A
A
A

70
9.7
586
5.5
1.9
29.3
1336
500
585
0.268
0.342
0.113
0.577
0.17
0.65

50
8.1
408
5.5
1.9
27.6
1097
500
553
0.387
0.494
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 9

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

34.3

581
521
734

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

513
478
647

2. Air temperature 40C

21.5

453
431
560

4. Depth of laying 800 mm

17.2

393
376
472

1 Ground temperature 35C

13.6

350
342
410

630
30.0
5548
4.5
2.6
49.6
7111
500
993
0.0283
0.0360
0.080
0.100
0.46
1.25

Assumption:

10.0

307
307
363

500
26.3
4272
4.5
2.5
45.6
5653
500
911
0.0366
0.0466
0.082
0.113
0.42
1.14

7.15

274
274
314

240
300
400
18.4
20.6
23.3
2074
2602
3327
4.5
4.5
4.5
2.2
2.3
2.4
36.8
39.2
42.3
3085
3713
4570
500
500
500
736
785
846
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.090 0.087
0.084
0.183 0.155
0.130
0.31
0.34
0.38
0.85
0.92
1.04

kA

230
230
249

120
150
185
12.9
14.6
16.0
1027
1267 1578
4.5
4.5
4.5
2.0
2.0
2.1
30.7
32.5
34.1
1799
2107 2482
500
500
500
614
651
682
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.099 0.096 0.093
0.338 0.280 0.229
0.24
0.26
0.28
0.65
0.71
0.77

188
192
206

95
11.4
814
4.5
1.9
29.0
1519
500
579
0.193
0.246
0.102
0.421
0.22
0.60

A
A
A

70
9.7
586
4.5
1.9
27.2
1232
500
545
0.268
0.342
0.107
0.576
0.20
0.54

50
8.1
408
4.5
1.8
25.3
981
500
506
0.387
0.494
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 8

11
12

42.9

71.5

90.1

727
666
988

114.5

795
727
1119

800
34.1
7100
8.0
3.0
62.0
9686
400
930
0.0221
0.0281
0.088
0.100
0.32
1.80

143.1

863
786
1241

1000
38.2
8900
8.0
3.2
66.5
11774
300
998
0.0176
0.0224
0.086
0.094
0.35
1.96

21.5

26.5

34.3

444
401
568

42.9

495
427
647

300
20.6
7806
2.8
3.15
3.5
77.7
14472
250
933
0.0601
0.0766
0.078
0.150
0.54
0.61

57.2

556
453
734

400
23.3
9981
2.8
3.15
3.7
84.2
17386
250
1010
0.0470
0.0599
0.076
0.125
0.61
0.69

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

17.2

389
350
481

240
18.4
6222
2.8
2.5
3.3
71.1
11509
250
853
0.0754
0.0961
0.080
0.178
0.49
0.55

for any other condition(s) please refer to the appropriate table for recommended installation data.

13.6

350
321
428

185
16.0
4734
2.8
2.5
3.1
65.2
9445
300
783
0.0991
0.1260
0.082
0.225
0.44
0.50

2. Air temperature 40C

10.0

307
291
376

150
14.6
3801
2.8
2.5
3.0
62.0
8211
400
744
0.1240
0.1581
0.084
0.276
0.40
0.45

4. Depth of laying 800 mm

7.15

274
260
328

120
12.9
3081
2.8
2.5
2.9
58.0
7110
400
696
0.153
0.195
0.086
0.334
0.37
0.42

1 Ground temperature 35C

5.00

230
222
271

95
11.4
2443
2.8
2.5
2.8
54.5
6153
500
654
0.193
0.246
0.089
0.418
0.34
0.38

Assumption:

3.58

188
188
219

70
9.7
1759
2.8
2.5
2.6
50.2
5076
500
603
0.268
0.342
0.092
0.573
0.30
0.34

2.29

155
147
146

50
8.1
1224
2.8
2.5
2.5
46.5
4214
500
558
0.387
0.494
0.097
0.824
0.26
0.30

kA

129
123
119

35
6.9
908.4
2.8
2.0
2.4
42.6
3297
500
511
0.524
0.668
0.102
1.11
0.23
0.26
99
92
90

16
25
4.8
5.9
414
655
2.8
2.8
2.0
2.0
2.2
2.3
37.5
40.1
2420
2859
500
500
450
482
1.15
0.727
1.47
0.927
0.1151 0.1074
2.44
1.54
0.18
0.21
0.20
0.23
A
A
A

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 11

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

57.2

649
598
857

for any other condition(s) please refer to the appropriate table for recommended installation data.

34.3

589
539
743

4. Depth of laying 800 mm

26.5

513
487
647

3. Thermal resistivity of soil 1.2C/m/W

21.5

453
444
568

2. Air temperature 40C

17.2

393
380
481

1 Ground temperature 35C

13.6

350
346
424

630
30.0
5548
8.0
2.9
57.5
7866
500
862
0.0283
0.0360
0.091
0.109
0.29
1.64

Assumption:

10.0

307
307
371

500
26.3
4272
8.0
2.7
53.3
6340
500
800
0.0366
0.0466
0.094
0.122
0.26
1.50

7.15

274
274
314

240
300
400
18.4
20.6
23.3
2074
2602
3327
8.0
8.0
8.0
2.4
2.5
2.6
44.4
47.0
49.9
3644
4316
5202
500
500
500
667
705
749
0.0754 0.0601 0.0470
0.0961 0.0766 0.0599
0.104 0.101
0.097
0.191 0.163
0.139
0.20
0.22
0.24
1.15
1.24
1.38

kA

230
230
262

120
150
185
12.9
14.6
16.0
1027
1267 1578
8.0
8.0
8.0
2.2
2.3
2.4
38.3
40.4
42.0
2278
2628 3026
500
500
500
575
606
629
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.116 0.112 0.109
0.343 0.286 0.236
0.16
0.17
0.19
0.91
0.98
1.05

188
192
214

95
11.4
814
8.0
2.2
36.8
1992
500
552
0.193
0.246
0.121
0.426
0.15
0.85

A
A
A

70
9.7
586
8.0
2.1
34.9
1666
500
523
0.268
0.342
0.127
0.579
0.14
0.77

50
8.1
408
8.0
2.1
33.2
1412
500
665
0.387
0.494
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Single Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 10

13
14

21.5

26.5

34.3

444
401
568

42.9

495
427
647

300
20.6
7806
3.4
3.15
3.7
82.2
15178
250
986
0.0601
0.0766
0.083
0.152
0.42
0.79

57.2

556
453
734

400
23.3
9981
3.4
3.15
3.9
88.6
18129
250
1064
0.0470
0.0599
0.080
0.128
0.47
0.89

26.5

42.9

57.2

556
453
734

400
23.3
9981
4.5
3.15
4
93.7
18984
250
1124
0.0470
0.0599
0.084
0.130
0.38
1.04

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible
for any loss or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of
the data without notice.

34.3

495
427
647

for any other condition(s) please refer to the appropriate table for recommended installation data.

21.5

444
401
568

4. Depth of laying 800 mm

17.2

389
350
481

3. Thermal resistivity of soil 1.2C/m/W

13.6

350
321
428

300
20.6
7806
4.5
3.15
3.8
87.2
15993
250
1047
0.0601
0.0766
0.087
0.155
0.34
0.92

2. Air temperature 40C

10.0

307
291
376

240
18.4
6222
4.5
3.15
3.7
82.2
13801
250
986
0.0754
0.0961
0.090
0.183
0.31
0.85

1 Ground temperature 35C

7.15

274
260
328

185
16.0
4734
4.5
3.15
3.5
76.3
11592
250
916
0.0991
0.1260
0.093
0.229
0.28
0.77

Assumption:

3.58

230
222
271

120
150
12.9
14.6
3081
3801
4.5
4.5
2.5
2.5
3.2
3.3
67.6
71.5
8315
9445
400
300
811
858
0.153 0.1240
0.195 0.1581
0.099 0.096
0.338 0.280
0.24
0.26
0.65
0.71

2.29

188
188
219

95
11.4
2443
4.5
2.5
3.1
64.0
7297
400
768
0.193
0.246
0.102
0.421
0.22
0.60

kA

155
147
146

70
9.7
1759
4.5
2.5
2.9
59.8
6186
500
718
0.268
0.342
0.107
0.576
0.20
0.54
129
123
119

50
8.1
1224
4.5
2.5
2.8
56.0
5263
500
672
0.387
0.494
0.113
0.826
0.18
0.49
A
A
A

35
6.9
908
4.5
2.5
2.7
53.2
4666
500
638
0.524
0.927
0.120
1.11
0.16
0.43

25
5.9
655
4.5
2.5
2.6
50.7
4161
500
608
0.727
1.47
0.126
1.54
0.14
0.39

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 13

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

17.2

389
350
481

for any other condition(s) please refer to the appropriate table for recommended installation data.

13.6

350
321
428

240
18.4
6222
3.4
3.15
3.5
76.9
12957
250
922
0.0754
0.0961
0.085
0.181
0.38
0.72

2. Air temperature 40C

10.0

307
291
376

185
16.0
4734
3.4
2.5
3.3
69.7
10034
300
836
0.0991
0.1260
0.088
0.227
0.34
0.65

4. Depth of laying 800 mm

7.15

274
260
328

150
14.6
3801
3.4
2.5
3.2
66.5
8782
300
798
0.1240
0.1581
0.090
0.278
0.32
0.60

1 Ground temperature 35C

5.00

230
222
271

120
12.9
3081
3.4
2.5
3.0
62.2
7628
400
747
0.153
0.195
0.093
0.336
0.29
0.55

Assumption:

3.58

188
188
219

95
11.4
2443
3.4
2.5
2.9
58.7
6652
500
705
0.193
0.246
0.096
0.420
0.27
0.50

2.29

155
147
146

70
9.7
1759
3.4
2.5
2.8
54.7
5578
500
656
0.268
0.342
0.100
0.574
0.24
0.45

kA

129
123
119

50
8.1
1224
3.4
2.5
2.6
50.7
4656
500
608
0.387
0.494
0.105
0.825
0.21
0.40

99
92
90

35
6.9
908.4
3.4
2.5
2.5
47.8
4078
500
574
0.524
0.668
0.111
1.11
0.19
0.36

A
A
A

25
5.9
654.9
3.4
2.0
2.4
44.4
3247
500
533
0.727
0.927
0.117
1.54
0.17
0.32

16
4.8
414
3.4
2.0
2.3
41.7
2782
500
500
1.15
1.47
0.126
2.44
0.15
0.28

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 12

15
16

34.3

57.2

17.2

21.5

324
282
376

26.5

368
316
428

34.3

419
363
498

3. Thermal resistivity of soil 1.2C/m/W

13.6

291
248
328

42.9

462
401
568

300
20.6
7806
8.0
3.15
4.4
104.2
19008
250
1563
0.0601
0.0766
0.101
0.163
0.22
1.24

57.2

513
453
647

400
23.3
9981
8.0
3.15
4.6
110.6
22138
250
1659
0.0470
0.0599
0.097
0.139
0.24
1.38

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

256
218
289

120
150
185
240
12.9
14.6
16.0
18.4
3081
3801
4734
6222
8.0
8.0
8.0
8.0
3.15
3.15
3.15
3.15
3.8
3.9
4.0
4.2
85.7
89.8
92.9
98.8
11639 12925 14303 16636
250
250
250
250
1286
1346
1394
1482
0.153 0.1240 0.0991 0.0754
0.195 0.1581 0.1260 0.0961
0.116 0.112 0.109 0.104
0.343 0.286 0.236 0.191
0.16
0.17
0.19
0.20
0.91
0.98
1.05
1.15

2. Air temperature 40C

7.15

kA

218
183
236

95
11.4
2443
8.0
3.15
3.7
82.2
10524
300
1233
0.193
0.246
0.121
0.426
0.15
0.85

4. Depth of laying 800 mm

180
154
192

A
A
A

70
9.7
1759
8.0
3.15
3.5
78.0
9250
300
1169
0.268
0.342
0.127
0.579
0.14
0.77

1 Ground temperature 35C

50
8.1
1224
8.0
2.5
3.4
72.9
7426
300
1094
0.387
0.494
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data. In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 15

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way
responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may
change any or whole of the data without notice.

42.9

504
462
647

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

453
410
568

4. Depth of laying 800 mm

21.5

410
368
498

3. Thermal resistivity of soil 1.2C/m/W

17.2

359
324
428

2. Air temperature 40C

13.6

321
286
376

400
23.3
9981
5.5
3.15
4.2
98.6
19865
250
1183
0.0470
0.0599
0.088
0.133
0.32
1.21

1 Ground temperature 35C

10.0

286
256
333

300
20.6
7806
5.5
3.15
4.0
92.2
16833
250
1106
0.0601
0.0766
0.092
0.157
0.29
1.08

Assumption:

7.15

252
222
289

240
18.4
6222
5.5
3.15
3.8
86.8
14544
250
1042
0.0754
0.0961
0.094
0.185
0.26
1.00

3.58

218
192
240

120
150
185
12.9
14.6
16.0
3081
3801
4734
5.5
5.5
5.5
2.5
3.15
3.15
3.3
3.5
3.6
72.2
77.7
81.0
8926 10971 12325
300
300
250
866
933
972
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90

kA

180
158
197

95
11.4
2443
5.5
2.5
3.2
68.7
7907
300
824
0.193
0.246
0.108
0.423
0.19
0.72

150
137
136

70
9.7
1759
5.5
2.5
3.1
64.6
6782
400
776
0.268
0.342
0.113
0.577
0.17
0.65

A
A
A

50
8.1
1224
5.5
2.5
3.0
60.9
5854
500
731
0.387
0.494
0.120
0.827
0.15
0.58

35
6.9
908.4
5.5
2.5
2.9
57.9
5221
500
696
0.524
0.927
0.127
1.12
0.14
0.52

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 14

17
18

21.5

26.5

34.3

444
385
518

42.9

490
425
591

300
20.6
7806
2.8
3.3
71.0
10349
250
1066
0.0601
0.0766
0.078
0.150
0.54
0.61

57.2

543
480
673

400
23.3
9981
2.8
3.5
77.5
12881
250
1162
0.0470
0.0599
0.076
0.125
0.61
0.69

21.5

26.5

34.3

444
385
518

42.9

490
425
591

300
20.6
7806
3.4
3.4
75.3
10761
250
1130
0.0601
0.0766
0.083
0.152
0.42
0.79

57.2

543
480
673

400
23.3
9981
3.4
3.7
81.9
13365
250
1229
0.0470
0.0599
0.080
0.128
0.47
0.89

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

17.2

390
335
446

for any other condition(s) please refer to the appropriate table for recommended installation data.

13.6

344
300
391

240
18.4
6222
3.4
3.3
70.2
8890
250
1052
0.0754
0.0961
0.085
0.181
0.38
0.72

2. Air temperature 40C

10.0

308
262
341

185
16.0
4734
3.4
3.1
64.3
7069
300
964
0.0991
0.1260
0.088
0.227
0.34
0.65

4. Depth of laying 800 mm

7.15

272
231
300

150
14.6
3801
3.4
3.0
61.1
5968
300
916
0.1240
0.1581
0.090
0.278
0.32
0.60

1 Ground temperature 35C

5.00

231
194
245

120
12.9
3081
3.4
2.8
56.8
5010
400
853
0.153
0.195
0.093
0.336
0.29
0.55

Assumption:

3.58

190
163
200

95
11.4
2443
3.4
2.7
53.3
4201
500
800
0.193
0.246
0.096
0.420
0.27
0.50

2.29

155
142
144

70
9.7
1759
3.4
2.6
49.3
3320
500
739
0.268
0.342
0.100
0.574
0.24
0.45

kA

125
123
119

50
8.1
1224
3.4
2.5
45.5
2604
500
682
0.387
0.494
0.105
0.825
0.21
0.40
103
91
91

35
6.9
908.4
3.4
2.4
42.6
2159
500
639
0.524
0.668
0.111
1.11
0.19
0.36
A
A
A

25
5.9
654.9
3.4
2.3
40.2
1797
500
603
0.727
0.927
0.117
1.54
0.17
0.32

16
4.8
414
3.4
2.2
37.5
1432
500
562
1.15
1.47
0.126
2.44
0.15
0.28

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 17

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

17.2

390
335
446

240
18.4
6222
2.8
3.1
65.7
8474
250
985
0.0754
0.0961
0.080
0.178
0.49
0.55

for any other condition(s) please refer to the appropriate table for recommended installation data.

13.6

344
300
391

185
16.0
4734
2.8
2.9
59.8
6687
300
897
0.0991
0.1260
0.082
0.225
0.44
0.50

2. Air temperature 40C

10.0

308
262
341

150
14.6
3801
2.8
2.8
56.6
5604
400
849
0.1240
0.1581
0.084
0.276
0.40
0.45

4. Depth of laying 800 mm

7.15

272
231
300

120
12.9
3081
2.8
2.7
52.6
4697
400
789
0.153
0.195
0.086
0.334
0.37
0.42

1 Ground temperature 35C

5.00

231
194
245

95
11.4
2443
2.8
2.6
49.1
3905
500
736
0.193
0.246
0.089
0.418
0.34
0.38

Assumption:

3.58

190
163
200

70
9.7
1759
2.8
2.5
45.0
3046
500
675
0.268
0.342
0.092
0.573
0.30
0.34

2.29

155
142
144

50
8.1
1224
2.8
2.3
41.1
2340
500
616
0.387
0.494
0.097
0.824
0.26
0.30

kA

125
123
119

35
6.9
908.4
2.8
2.2
38.2
1902
500
572
0.524
0.668
0.102
1.11
0.23
0.26

103
91
91

16
25
4.8
5.9
414
655
2.8
2.8
2.1
2.2
33.3
35.9
1229
1571
500
500
500
539
1.15
0.727
1.47
0.927
0.1151 0.1074
2.44
1.54
0.18
0.21
0.20
0.23

A
A
A

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 16

19
20

26.5

42.9

57.2

543
480
673

400
23.3
9981
4.5
3.8
87.0
13914
250
1305
0.0470
0.0599
0.084
0.130
0.38
1.04

34.3

57.2

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way
responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may
change any or whole of the data without notice.

42.9

537
486
673

for any other condition(s) please refer to the appropriate table for recommended installation data.

26.5

485
433
591

4. Depth of laying 800 mm

21.5

435
390
518

3. Thermal resistivity of soil 1.2C/m/W

17.2

380
344
446

2. Air temperature 40C

13.6

340
303
391

400
23.3
9981
5.5
4.0
91.9
14508
250
1379
0.0470
0.0599
0.088
0.133
0.32
1.21

1 Ground temperature 35C

10.0

303
272
346

300
20.6
7806
5.5
3.8
85.5
11859
250
1282
0.0601
0.0766
0.092
0.157
0.29
1.08

Assumption:

7.15

268
235
300

240
18.4
6222
5.5
3.6
80.1
9884
250
1202
0.0754
0.0961
0.094
0.185
0.26
1.00

3.58

231
204
250

120
150
185
12.9
14.6
16.0
3081
3801
4734
5.5
5.5
5.5
3.2
3.3
3.4
67.0
71.0
74.3
5868
6849
8006
300
300
250
1005
1066
1115
0.153 0.1240 0.0991
0.195 0.1581 0.1260
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90

kA

190
168
204

95
11.4
2443
5.5
3.1
63.5
5014
300
952
0.193
0.246
0.108
0.423
0.19
0.72
157
139
140

70
9.7
1759
5.5
2.9
59.2
4053
400
889
0.268
0.342
0.113
0.577
0.17
0.65
A
A
A

50
8.1
1224
5.5
2.8
55.5
3301
500
833
0.387
0.494
0.120
0.827
0.15
0.58

35
6.9
908.4
5.5
2.7
52.57
2808
500
789
0.524
0.927
0.127
1.12
0.14
0.52

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 19

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible
for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole
of the data without notice.

34.3

490
425
591

for any other condition(s) please refer to the appropriate table for recommended installation data.

21.5

444
385
518

4. Depth of laying 800 mm

17.2

390
335
446

3. Thermal resistivity of soil 1.2C/m/W

13.6

344
300
391

300
20.6
7806
4.5
3.6
80.5
11306
250
1208
0.0601
0.0766
0.087
0.155
0.34
0.92

2. Air temperature 40C

10.0

308
262
341

240
18.4
6222
4.5
3.4
75.3
9383
250
1130
0.0754
0.0961
0.090
0.183
0.31
0.85

1 Ground temperature 35C

7.15

272
231
300

185
16.0
4734
4.5
3.3
69.6
7557
250
1044
0.0991
0.1260
0.093
0.229
0.28
0.77

Assumption:

3.58

231
194
245

120
150
12.9
14.6
3081
3801
4.5
4.5
3.0
3.1
62.2
66.1
5447
6388
400
300
933
992
0.153 0.1240
0.195 0.1581
0.099 0.096
0.338 0.280
0.24
0.26
0.65
0.71

2.29

190
163
200

95
11.4
2443
4.5
2.9
58.6
4600
400
879
0.193
0.246
0.102
0.421
0.22
0.60

kA

155
142
144

70
9.7
1759
4.5
2.8
54.6
3705
500
819
0.268
0.342
0.107
0.576
0.20
0.54

125
123
119

50
8.1
1224
4.5
2.6
50.6
2939
500
759
0.387
0.494
0.113
0.826
0.18
0.49

A
A
A

35
6.9
908
4.5
2.5
47.8
2476
500
716
0.524
0.927
0.120
1.11
0.16
0.43

25
5.9
655
4.5
2.5
45.5
2109
500
682
0.727
1.47
0.126
1.54
0.14
0.39

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 18

21
22

17.2

21.5

340
303
391

26.5

380
344
446

185
16.0
4734
8.0
3.8
86.2
9280
250
1725
0.0991
0.1269
0.109
0.236
0.19
1.05

34.3

435
390
518

240
18.4
6222
8.0
4
92.1
11266
250
1842
0.0754
0.0961
0.104
0.191
0.20
1.15

3. Thermal resistivity of soil 1.2C/m/W

13.6

303
272
346

150
14.6
3801
8.0
3.7
83.1
8091
250
1661
0.1249
0.1581
0.112
0.286
0.17
0.98

42.9

485
433
591

300
20.6
7806
8.0
4.2
97.5
13323
250
1949
0.0601
0.0766
0.101
0.163
0.22
1.24

57.2

537
486
673

400
23.3
9981
8.0
4.4
103.9
16070
250
2078
0.0470
0.0599
0.097
0.139
0.24
1.38

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

268
235
300

120
12.9
3081
8.0
3.6
79.0
7049
250
1580
0.153
0.195
0.116
0.343
0.16
0.91

4. Depth of laying 800 mm

7.15

kA

231
204
250

95
11.4
2443
8.0
3.4
75.3
6106
300
1506
0.193
0.246
0.121
0.426
0.15
0.85

2. Air temperature 40C

190
168
204

A
A
A

70
9.7
1759
8.0
3.3
71.3
5114
300
1425
0.268
0.342
0.127
0.579
0.14
0.77

1 Ground temperature 35C

50
8.1
1224
8.0
3.2
67.5
4307
300
1351
0.387
0.494
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

17.2

21.5

350
321
428

26.5

389
350
481

185
16.0
4734
2.8
0.5
3.0
62.0
7747
300
783
0.0991
0.1260
0.082
0.225
0.44
0.50

34.3

444
401
568

240
18.4
6222
2.8
0.5
3.2
67.9
9641
250
853
0.0754
0.0961
0.080
0.178
0.49
0.55

3. Thermal resistivity of soil 1.2C/m/W

13.6

307
291
376

150
14.6
3801
2.8
0.5
2.9
58.8
6607
400
744
0.1240
0.1581
0.084
0.276
0.40
0.45

42.9

495
427
647

300
20.6
7806
2.8
0.5
3.4
73.2
11613
250
933
0.0601
0.0766
0.078
0.150
0.54
0.61

57.2

556
453
734

400
23.3
9981
2.8
0.8
3.6
80.9
15068
250
1010
0.0470
0.0599
0.076
0.125
0.61
0.69

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

274
260
328

120
12.9
3081
2.8
0.5
2.8
54.8
5625
400
696
0.153
0.195
0.086
0.334
0.37
0.42

2. Air temperature 40C

7.15

kA

230
222
271

95
11.4
2443
2.8
0.5
2.7
51.3
4769
500
654
0.193
0.246
0.089
0.418
0.34
0.38

4. Depth of laying 800 mm

188
188
219

A
A
A

70
9.7
1759
2.8
0.5
2.5
47.0
3813
500
603
0.268
0.342
0.092
0.573
0.30
0.34

1 Ground temperature 35C

50
8.1
1224
2.8
0.5
2.4
43.3
3061
500
558
0.387
0.494
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal steel tape thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 21

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 20

23
24

21.5

350
321
428

26.5

389
350
481

185
16.0
4734
3.4
0.5
3.2
66.5
8209
300
836
0.0991
0.1260
0.088
0.227
0.34
0.65

34.3

444
401
568

240
18.4
6222
3.4
0.5
3.3
72.2
10102
250
922
0.0754
0.0961
0.085
0.181
0.38
0.72

3. Thermal resistivity of soil 1.2C/m/W

13.6

307
291
376

150
14.6
3801
3.4
0.5
3.0
63.1
7020
300
798
0.1240
0.1581
0.090
0.278
0.32
0.60

42.9

495
427
647

300
20.6
7806
3.4
0.5
3.5
77.5
12103
250
986
0.0601
0.0766
0.083
0.152
0.42
0.79

57.2

556
453
734

400
23.3
9981
3.4
0.8
3.8
85.3
15678
250
1064
0.0470
0.0599
0.080
0.128
0.47
0.89

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

274
260
328

120
12.9
3081
3.4
0.5
2.9
59.0
6017
400
747
0.153
0.195
0.093
0.336
0.29
0.55

2. Air temperature 40C

7.15

kA

230
222
271

95
11.4
2443
3.4
0.5
2.8
55.5
5143
500
705
0.193
0.246
0.096
0.420
0.27
0.50

4. Depth of laying 800 mm

188
188
219

A
A
A

70
9.7
1759
3.4
0.5
2.7
51.5
4188
500
656
0.268
0.342
0.100
0.574
0.24
0.45

1 Ground temperature 35C

50
8.1
1224
3.4
0.5
2.5
47.5
3380
500
608
0.387
0.494
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

17.2

21.5

350
321
428

26.5

389
350
481

34.3

444
401
568

185
240
16.0
18.4
4734
6222
4.5
4.5
0.5
0.5
3.3
3.5
71.6
77.5
8760 10725
250
250
916
986
0.0991 0.0754
0.1260 0.0961
0.093 0.090
0.229 0.183
0.28
0.31
0.77
0.85

3. Thermal resistivity of soil 1.2C/m/W

13.6

307
291
376

150
14.6
3801
4.5
0.5
3.2
68.3
7564
300
858
0.1240
0.1581
0.096
0.280
0.26
0.71

42.9

495
427
647

300
20.6
7806
4.5
0.8
3.7
83.9
13582
250
1047
0.0601
0.0766
0.087
0.155
0.34
0.92

57.2

556
453
734

400
23.3
9981
4.5
0.8
3.9
90.4
16376
250
1124
0.0470
0.0599
0.084
0.130
0.38
1.04

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

274
260
328

120
12.9
3081
4.5
0.5
3.1
64.4
6550
400
811
0.153
0.195
0.099
0.338
0.24
0.65

2. Air temperature 40C

7.15

kA

230
222
271

95
11.4
2443
4.5
0.5
3.0
60.8
5637
400
768
0.193
0.246
0.102
0.421
0.22
0.60

1 Ground temperature 35C

188
188
219

A
A
A

70
9.7
1759
4.5
0.5
2.8
56.6
4643
500
718
0.268
0.342
0.107
0.576
0.20
0.54

4. Depth of laying 800 mm

50
8.1
1224
4.5
0.5
2.7
52.8
3832
500
672
0.387
0.494
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal steel tape thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 23

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential ,due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal steel tape thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 22

25
26

17.2

21.5

321
286
376

26.5

359
324
428

185
16.0
4734
5.5
0.5
3.5
76.5
9330
250
972
0.0991
0.1260
0.098
0.231
0.24
0.90

34.3

410
368
498

240
18.4
6222
5.5
0.5
3.7
82.3
11312
250
1042
0.0754
0.0961
0.094
0.185
0.26
1.00

3. Thermal resistivity of soil 1.2C/m/W

13.6

286
256
333

150
14.6
3801
5.5
0.5
3.4
73.2
8112
300
933
0.1240
0.1581
0.101
0.282
0.22
0.84

42.9

453
410
568

300
20.6
7806
5.5
0.8
3.9
88.9
14274
250
1106
0.0601
0.0766
0.092
0.157
0.29
1.08

57.2

504
462
647

400
23.3
9981
5.5
0.8
4.1
95.3
17109
250
1183
0.0470
0.0599
0.088
0.133
0.32
1.21

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

252
222
289

120
12.9
3081
5.5
0.5
3.2
69.0
7024
300
866
0.153
0.195
0.104
0.339
0.21
0.77

4. Depth of laying 800 mm

7.15

kA

218
192
240

95
11.4
2443
5.5
0.5
3.1
65.5
6108
300
824
0.193
0.246
0.108
0.423
0.19
0.72

2. Air temperature 40C

180
158
197

A
A
A

70
9.7
1759
5.5
0.5
3.0
61.4
5102
400
776
0.268
0.342
0.113
0.577
0.17
0.65

1 Ground temperature 35C

50
8.1
1224
5.5
0.5
2.9
57.7
4283
500
731
0.387
0.494
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

17.2

21.5

324
282
376

26.5

368
316
428

185
16.0
4734
8.0
0.5
3.9
88.4
10819
250
1115
0.0991
0.1260
0.109
0.236
0.19
1.05

34.3

419
363
498

240
18.4
6222
8.0
0.8
4.1
95.5
13873
250
1186
0.0754
0.0961
0.104
0.191
0.20
1.15

3. Thermal resistivity of soil 1.2C/m/W

13.6

291
248
328

150
14.6
3801
8.0
0.5
3.8
85.3
9573
250
1077
0.1240
0.1581
0.112
0.286
0.17
0.98

42.9

462
401
568

300
20.6
7806
8.0
0.8
4.3
100.9
16083
250
1250
0.0601
0.0766
0.101
0.163
0.22
1.24

57.2

513
453
647

400
23.3
9981
8.0
0.8
4.5
107.3
19017
250
1327
0.0470
0.0599
0.097
0.139
0.24
1.38

for any other condition(s) please refer to the appropriate table for recommended installation data.

10.0

256
218
289

120
12.9
3081
8.0
0.5
3.6
81.0
8417
250
1028
0.153
0.195
0.116
0.343
0.16
0.91

4. Depth of laying 800 mm

7.15

kA

218
183
236

95
11.4
2443
8.0
0.5
3.5
77.5
7448
300
986
0.193
0.246
0.121
0.426
0.15
0.85

2. Air temperature 40C

180
154
192

A
A
A

70
9.7
1759
8.0
0.5
3.4
73.5
6381
300
935
0.268
0.342
0.127
0.579
0.14
0.77

1 Ground temperature 35C

50
8.1
1224
8.0
0.5
3.3
69.7
5506
300
875
0.387
0.494
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
hm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal steel tape thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 25

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal steel tape thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Copper conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 24

27
28

28.2

47.0

59.2

547
470
770

75.2

598
504
857

800
34.14
2188
2.8
2.5
2.8
55.2
4416
400
828
0.0367
0.0470
0.073
0.087
0.71
0.81

94.0

649
547
944

1000
38.2
2759
2.8
2.5
2.9
59.6
5243
300
894
0.0291
0.0370
0.073
0.082
0.75
0.85

28.2

37.6

47.0

487
427
673

59.2

547
470
770

75.2

598
504
857

800
34.14
2188
3.4
2.5
2.8
57.0
4609
400
855
0.0367
0.0470
0.075
0.089
0.63
1.20

94.0

649
547
944

1000
38.2
2759
3.4
2.5
3
61.7
5479
300
925
0.0291
0.0370
0.074
0.083
0.70
1.32

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

22.6

436
389
585

for any other condition(s) please refer to the appropriate table for recommended installation data.

17.4

389
359
507

2. Air temperature 40C

14.1

346
324
446

4. Depth of laying 800 mm

11.3

303
286
380

1 Ground temperature 35C

8.9

269
256
333

630
30.0
1721
3.4
2.5
2.7
52.6
3889
500
789
0.0469
0.0600
0.077
0.097
0.57
1.08

Assumption:

6.6

239
235
311

500
26.3
1307
3.4
2.5
2.6
48.5
3240
500
728
0.0605
0.0770
0.079
0.110
0.52
0.97

4.7

214
209
257

240
300
400
18.4
20.6
23.3
646
803
1027
3.4
3.4
3.4
2.0
2.0
2.0
2.2
2.3
2.4
38.6
41.0
44.1
1962
2242
2626
500
500
500
578
615
661
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.085 0.083
0.080
0.181 0.152
0.128
0.38
0.42
0.47
0.72
0.79
0.89

kA

180
180
210

120
150
185
12.9
14.6
16.0
317
390
493
3.4
3.4
3.4
2.0
2.0
2.0
2.0
2.1
2.2
32.5
34.4
36.0
1336
1502 1685
500
500
500
487
516
540
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.093 0.090 0.088
0.336 0.278 0.227
0.29
0.32
0.34
0.55
0.60
0.65
145
145
170

95
11.4
251
3.4
2.0
2
30.9
1202
500
464
0.320
0.408
0.096
0.420
0.27
0.50
A
A
A

70
9.7
182
3.4
2.0
1.9
28.9
1035
500
433
0.443
0.565
0.100
0.574
0.24
0.45

50
8.1
125
3.4
2.0
1.9
27.3
908
500
409
0.641
0.818
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 27

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

487
427
673

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

436
389
585

4. Depth of laying 800 mm

17.4

389
359
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

346
324
446

2. Air temperature 40C

11.3

303
286
380

1 Ground temperature 35C

8.9

269
256
333

630
30.0
1721
2.8
2.5
2.6
50.5
3673
500
757
0.0469
0.0600
0.074
0.095
0.68
0.77

Assumption:

6.6

239
235
311

500
26.3
1307
2.8
2.5
2.5
46.5
3050
500
697
0.0605
0.0770
0.075
0.108
0.65
0.74

4.7

214
209
257

240
300
400
18.4
20.6
23.3
646
803
1027
2.8
2.8
2.8
2.0
2.0
2.0
2.2
2.3
2.4
36.6
39.2
42.1
1819
2101
2465
500
500
500
549
588
632
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.080 0.078
0.076
0.178 0.150
0.125
0.49
0.54
0.61
0.55
0.61
0.69

kA

180
180
210

120
150
185
12.9
14.6
16.0
317
390
493
2.8
2.8
2.8
2.0
2.0
2.0
2.0
2.0
2.1
30.6
32.3
33.9
1221
1366 1543
500
500
500
459
485
509
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.086 0.084 0.082
0.334 0.276 0.225
0.37
0.40
0.44
0.42
0.45
0.50

145
145
170

95
11.4
251
2.8
2.0
1.9
28.8
1071
500
432
0.320
0.408
0.089
0.418
0.34
0.38

A
A
A

70
9.7
182
2.8
2.0
1.9
27.1
931
500
406
0.443
0.565
0.092
0.573
0.30
0.34

50
8.1
125
2.8
2.0
1.8
25.2
796
500
378
0.641
0.818
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV ,Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 26

29
30

28.2

47.0

59.2

547
470
770

75.2

598
504
857

800
34.14
2188
4.5
2.5
2.9
59.6
4897
400
893
0.0367
0.0470
0.078
0.091
0.51
1.39

94.0

649
547
944

1000
38.2
2759
4.5
2.5
3.1
64.1
5773
300
962
0.0291
0.0370
0.077
0.085
0.56
1.53

28.2

47.0

59.2

547
478
770

75.2

598
513
857

800
34.1
2188
5.5
2.5
3
61.8
5159
400
927
0.0367
0.0470
0.081
0.094
0.43
1.61

94.0

649
547
944

1000
38.2
2759
5.5
2.5
3.2
66.4
6068
300
997
0.0291
0.0370
0.080
0.088
0.47
1.77

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

487
436
673

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

436
393
585

4. Depth of laying 800 mm

17.4

385
354
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

346
324
446

2. Air temperature 40C

11.3

300
286
385

1 Ground temperature 35C

8.9

265
256
336

630
30.0
1721
5.5
2.5
2.9
57.3
4389
500
859
0.0469
0.0600
0.084
0.103
0.39
1.46

Assumption:

6.6

239
235
297

500
26.3
1307
5.5
2.5
2.7
53.1
3694
500
797
0.0605
0.0770
0.086
0.116
0.35
1.33

4.7

214
209
257

240
300
400
18.4
20.6
23.3
646
803
1027
5.5
5.5
5.5
2.0
2.0
2.5
2.4
2.5
2.6
43.2
45.8
49.7
2340
2651
3194
500
500
500
649
687
746
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.094 0.092
0.088
0.185 0.157
0.133
0.26
0.29
0.32
1.00
1.08
1.21

kA

180
175
214

120
150
185
12.9
14.6
16.0
317
390
493
5.5
5.5
5.5
2.0
2.0
2.0
2.2
2.3
2.3
37.2
39.2
40.6
1673
1855 2032
500
500
500
559
588
608
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90
145
145
175

95
11.4
251
5.5
2.0
2.1
35.4
1501
500
531
0.320
0.408
0.108
0.423
0.19
0.72
A
A
A

70
9.7
182
5.5
2.0
2.1
33.7
1342
500
505
0.443
0.565
0.113
0.577
0.17
0.65

50
8.1
125
5.5
2.0
2
31.8
1186
500
478
0.641
0.818
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 29

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

487
427
673

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

436
389
585

4. Depth of laying 800 mm

17.4

389
359
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

346
324
446

2. Air temperature 40C

11.3

303
286
380

1 Ground temperature 35C

8.9

269
256
333

630
30.0
1721
4.5
2.5
2.8
55.0
4145
500
826
0.0469
0.0600
0.080
0.100
0.46
1.25

Assumption:

6.6

239
235
311

500
26.3
1307
4.5
2.5
2.6
50.8
3454
500
761
0.0605
0.0770
0.082
0.113
0.42
1.14

4.7

214
209
257

240
300
400
18.4
20.6
23.3
646
803
1027
4.5
4.5
4.5
2.0
2.0
2.5
2.3
2.4
2.5
41.0
43.4
47.5
2154
2445
2980
500
500
500
615
652
713
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.090 0.087
0.084
0.183 0.155
0.130
0.31
0.34
0.38
0.85
0.92
1.04

kA

180
180
210

120
150
185
12.9
14.6
16.0
317
390
493
4.5
4.5
4.5
2.0
2.0
2.0
2.1
2.2
2.2
34.9
36.9
38.3
1502
1686 1857
500
500
500
523
554
575
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.099 0.096 0.093
0.338 0.280 0.229
0.24
0.26
0.28
0.65
0.71
0.77

145
145
170

95
11.4
251
4.5
2.0
2.1
33.4
1362
500
500
0.320
0.408
0.102
0.421
0.22
0.60

A
A
A

70
9.7
182
4.5
2.0
2
31.4
1194
500
471
0.443
0.565
0.107
0.576
0.20
0.54

50
8.1
125
4.5
2.0
1.9
29.5
1038
500
442
0.641
0.818
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 28

31
32

28.2

47.0

59.2

547
478
770

75.2

598
513
857

800
34.1
2188
8.0
2.5
3.2
67.4
5851
400
1011
0.0367
0.0470
0.088
0.100
0.32
1.80

94.0

649
547
944

1000
38.2
2759
8.0
2.5
3.3
71.7
6754
300
1076
0.0291
0.0370
0.086
0.094
0.35
1.96

28.2

37.6

47.0

521
487
691

59.2

581
547
795

75.2

658
607
926

800
34.14
2188
2.8
2.6
49.8
3552
400
996
0.0367
0.0470
0.073
0.087
0.71
0.81

94.0

727
675
1040

1000
38.2
2759
2.8
2.8
54.4
4327
300
1088
0.0291
0.0370
0.073
0.082
0.75
0.85

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

22.6

462
436
585

for any other condition(s) please refer to the appropriate table for recommended installation data.

17.4

406
389
507

2. Air temperature 40C

14.1

354
346
437

4. Depth of laying 800 mm

11.3

307
300
371

1 Ground temperature 35C

8.9

274
269
319

630
30.0
1721
2.8
2.5
45.3
2913
500
905
0.0469
0.0600
0.074
0.095
0.68
0.77

Assumption:

6.6

239
244
279

500
26.3
1307
2.8
2.3
41.1
2338
500
822
0.0605
0.0770
0.075
0.108
0.65
0.74

4.7

214
218
245

240
300
400
18.4
20.6
23.3
646
803
1027
2.8
2.8
2.8
2.0
2.1
2.2
32.2
34.8
37.7
1367
1613
1936
500
500
500
644
695
754
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.080 0.078
0.076
0.178 0.150
0.125
0.49
0.54
0.61
0.55
0.61
0.69

kA

180
183
197

120
150
185
12.9
14.6
16.0
317
390
493
2.8
2.8
2.8
1.8
1.9
2.0
26.2
28.1
29.7
854
987
1142
500
500
500
524
563
595
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.086 0.084 0.082
0.334 0.276 0.225
0.37
0.40
0.44
0.42
0.45
0.50
145
150
158

95
11.4
251
2.8
1.8
24.6
740
500
492
0.320
0.408
0.089
0.418
0.34
0.38
A
A
A

70
9.7
182
2.8
1.7
22.7
614
500
453
0.443
0.565
0.092
0.573
0.30
0.34

50
8.1
125
2.8
1.7
21.0
515
500
420
0.641
0.818
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 31

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

487
436
673

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

436
393
585

4. Depth of laying 800 mm

17.4

385
354
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

346
324
446

2. Air temperature 40C

11.3

300
286
385

1 Ground temperature 35C

8.9

265
256
336

630
30.0
1721
8.0
2.5
3
62.7
5007
500
940
0.0469
0.0600
0.091
0.109
0.29
1.64

Assumption:

6.6

239
235
297

500
26.3
1307
8.0
2.5
2.9
58.7
4301
500
881
0.0605
0.0770
0.094
0.122
0.26
1.50

4.7

214
209
257

240
300
400
18.4
20.6
23.3
646
803
1027
8.0
8.0
8.0
2.0
2.5
2.5
2.6
2.7
2.8
48.8
52.4
55.3
2842
3332
3769
500
500
500
733
786
830
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.104 0.101
0.097
0.191 0.163
0.139
0.20
0.22
0.24
1.15
1.24
1.38

kA

180
175
214

120
150
185
12.9
14.6
16.0
317
390
493
8.0
8.0
8.0
2.0
2.0
2.0
2.4
2.4
2.5
42.7
44.6
46.2
2107
2297 2508
500
500
500
641
669
692
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.116 0.112 0.109
0.343 0.286 0.236
0.16
0.17
0.19
0.91
0.98
1.05

145
145
175

95
11.4
251
8.0
2.0
2.3
41.0
1927
500
615
0.320
0.408
0.121
0.426
0.15
0.85

A
A
A

70
9.7
182
8.0
2.0
2.3
39.3
1751
500
589
0.443
0.565
0.127
0.579
0.14
0.77

50
8.1
125
8.0
2.0
2.2
37.4
1577
500
562
0.641
0.818
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Aluminium Round Wire Armoured cable
Table 30

33
34

28.2

37.6

47.0

521
487
691

59.2

581
547
795

75.2

658
607
926

800
34.14
2188
3.4
2.7
51.8
3737
400
1036
0.0367
0.0470
0.075
0.089
0.63
1.20

94.0

727
675
1040

1000
38.2
2759
3.4
2.8
56.3
4502
300
1125
0.0291
0.0370
0.074
0.083
0.70
1.32

28.2

47.0

59.2

581
547
795

75.2

658
607
926

800
34.14
2188
4.5
2.8
54.4
3982
400
1087
0.0367
0.0470
0.078
0.091
0.51
1.39

94.0

727
675
1040

1000
38.2
2759
4.5
2.9
58.7
4753
300
1174
0.0291
0.0370
0.077
0.085
0.56
1.53

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

521
487
691

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

462
436
585

4. Depth of laying 800 mm

17.4

406
389
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

354
346
437

2. Air temperature 40C

11.3

307
300
371

1 Ground temperature 35C

8.9

274
269
319

630
30.0
1721
4.5
2.6
49.6
3284
500
993
0.0469
0.0600
0.080
0.100
0.46
1.25

Assumption:

6.6

239
244
279

500
26.3
1307
4.5
2.5
45.6
2688
500
911
0.0605
0.0770
0.082
0.113
0.42
1.14

4.7

214
218
245

240
300
400
18.4
20.6
23.3
646
803
1027
4.5
4.5
4.5
2.2
2.3
2.4
36.8
39.2
42.3
1657
1914
2270
500
500
500
736
785
846
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.090 0.087
0.084
0.183 0.155
0.130
0.31
0.34
0.38
0.85
0.92
1.04

kA

180
183
197

120
150
185
12.9
14.6
16.0
317
390
493
4.5
4.5
4.5
2.0
2.0
2.1
30.7
32.5
34.1
1089
1229 1397
500
500
500
614
651
682
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.099 0.096 0.093
0.338 0.280 0.229
0.24
0.26
0.28
0.65
0.71
0.77
145
150
158

95
11.4
251
4.5
1.9
29.0
956
500
579
0.320
0.408
0.102
0.421
0.22
0.60
A
A
A

70
9.7
182
4.5
1.9
27.2
828
500
545
0.443
0.565
0.107
0.576
0.20
0.54

50
8.1
125
4.5
1.8
25.3
698
500
506
0.641
0.818
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 33

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

3. Thermal resistivity of soil 1.2C/m/W

22.6

462
436
585

for any other condition(s) please refer to the appropriate table for recommended installation data.

17.4

406
389
507

2. Air temperature 40C

14.1

354
346
437

4. Depth of laying 800 mm

11.3

307
300
371

1 Ground temperature 35C

8.9

274
269
319

630
30.0
1721
3.4
2.5
47.2
3070
500
944
0.0469
0.0600
0.077
0.097
0.57
1.08

Assumption:

6.6

239
244
279

500
26.3
1307
3.4
2.4
43.1
2492
500
862
0.0605
0.0770
0.079
0.110
0.52
0.97

4.7

214
218
245

240
300
400
18.4
20.6
23.3
646
803
1027
3.4
3.4
3.4
2.1
2.2
2.3
34.4
36.8
39.9
1498
1745
2087
500
500
500
687
736
797
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.085 0.083
0.080
0.181 0.152
0.128
0.38
0.42
0.47
0.72
0.79
0.89

kA

180
183
197

120
150
185
12.9
14.6
16.0
317
390
493
3.4
3.4
3.4
1.9
2.0
2.0
28.3
30.2
31.6
956
1096 1242
500
500
500
565
604
631
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.093 0.090 0.088
0.336 0.278 0.227
0.29
0.32
0.34
0.55
0.60
0.65

145
150
158

95
11.4
251
3.4
1.9
26.7
843
500
534
0.320
0.408
0.096
0.420
0.27
0.50

A
A
A

70
9.7
182
3.4
1.8
24.7
704
500
494
0.443
0.565
0.100
0.574
0.24
0.45

50
8.1
125
3.4
1.7
22.9
588
500
457
0.641
0.818
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 32

35
36

28.2

47.0

59.2

589
658
804

75.2

658
684
926

800
34.1
2188
5.5
2.8
56.4
4179
400
1128
0.0367
0.0470
0.081
0.094
0.43
1.61

94.0

734
675
1057

1000
38.2
2759
5.5
3.0
61.0
5008
300
1221
0.0291
0.0370
0.080
0.088
0.47
1.77

2. Air temperature 40C

Assumption:

6.6

8.9

214
215
245

95
11.4
251
8.0
2.2
36.8
1429
500
736
0.320
0.408
0.121
0.426
0.15
0.85

14.1

274
274
328

17.4

307
354
376

22.6

354
393
446

28.2

406
444
507

37.6

470
487
595

240
300
400
18.4
20.6
23.3
646
803
1027
8.0
8.0
8.0
2.4
2.5
2.6
44.4
47.0
49.9
2216
2517
2902
500
500
500
889
940
999
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.104 0.101
0.097
0.191 0.163
0.139
0.20
0.22
0.24
1.15
1.24
1.38

3. Thermal resistivity of soil 1.2C/m/W

11.3

239
239
289

120
150
185
12.9
14.6
16.0
317
390
493
8.0
8.0
8.0
2.2
2.3
2.4
38.3
40.4
42.0
1568
1751 1941
500
500
500
767
807
839
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.116 0.112 0.109
0.343 0.286 0.236
0.16
0.17
0.19
0.91
0.98
1.05

47.0

521
556
691

500
26.3
1307
8.0
2.7
53.3
3375
500
1066
0.0605
0.0770
0.094
0.122
0.26
1.50

59.2

589
658
804

630
30.0
1721
8.0
2.9
57.5
4039
500
1150
0.0469
0.0600
0.091
0.109
0.29
1.64

75.2

658
684
926

800
34.1
2188
8.0
3.0
62.0
4774
400
1240
0.0367
0.0470
0.088
0.100
0.32
1.80

94.0

734
675
1057

1000
38.2
2759
8.0
3.2
66.5
5633
300
1331
0.0291
0.0370
0.086
0.094
0.35
1.96

4. Depth of laying 800 mm


for any other condition(s) please refer to the appropriate table for recommended installation data.
Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

1 Ground temperature 35C

4.7

kA

180
180
205

145
150
166

A
A
A

70
9.7
182
8.0
2.1
34.9
1261
500
697
0.443
0.565
0.127
0.579
0.14
0.77

50
8.1
125
8.0
2.1
33.2
1129
500
665
0.641
0.818
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 35

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman is in no way responsible for any loss
or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development & improvement Nuhas Oman may change any or whole of the data without notice.

37.6

521
556
691

for any other condition(s) please refer to the appropriate table for recommended installation data.

22.6

470
487
595

4. Depth of laying 800 mm

17.4

406
444
507

3. Thermal resistivity of soil 1.2C/m/W

14.1

354
393
446

2. Air temperature 40C

11.3

307
354
376

1 Ground temperature 35C

8.9

274
274
328

630
30.0
1721
5.5
2.7
51.9
3489
500
1038
0.0469
0.0600
0.084
0.103
0.39
1.46

Assumption:

6.6

239
239
289

500
26.3
1307
5.5
2.5
47.7
2866
500
954
0.0605
0.0770
0.086
0.116
0.35
1.33

4.7

214
215
245

240
300
400
18.4
20.6
23.3
646
803
1027
5.5
5.5
5.5
2.3
2.3
2.4
39.0
41.4
44.3
1812
2069
2425
500
500
500
781
828
887
0.1250 0.1000 0.0778
0.1600 0.1280 0.0990
0.094 0.092
0.088
0.185 0.157
0.133
0.26
0.29
0.32
1.00
1.08
1.21

kA

180
180
205

120
150
185
12.9
14.6
16.0
317
390
493
5.5
5.5
5.5
2.1
2.1
2.2
33.0
34.8
36.4
1227
1367 1541
500
500
500
661
695
727
0.253 0.2060 0.1640
0.323 0.2630 0.2090
0.104 0.101 0.098
0.339 0.282 0.231
0.21
0.22
0.24
0.77
0.84
0.90

145
150
166

95
11.4
251
5.5
2.0
31.2
1080
500
624
0.320
0.408
0.108
0.423
0.19
0.72

A
A
A

70
9.7
182
5.5
1.9
29.3
931
500
585
0.443
0.565
0.113
0.577
0.17
0.65

50
8.1
125
5.5
1.9
27.6
814
500
553
0.641
0.818
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Single Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 34

37
38

11.3

14.1

256
218
289

17.4

286
248
336

185
16.0
1477.5
2.8
2.5
3.1
65.2
6189
300
783
0.1640
0.2090
0.082
0.225
0.44
0.50

3. Thermal resistivity of soil 1.

8.9

227
192
257

150
14.6
1168.5
2.8
2.5
3.0
62.0
5579
400
744
0.2060
0.2630
0.084
0.276
0.40
0.45

22.6

324
286
393

240
18.4
1938
2.8
2.5
3.3
71.1
7225
250
853
0.1250
0.1600
0.080
0.178
0.49
0.55

28.2

372
321
446

300
20.6
2409
2.8
3.15
3.5
77.7
9075
250
933
0.1000
0.1280
0.078
0.150
0.54
0.61

37.6

419
368
516

400
23.3
3080
2.8
3.15
3.7
84.2
10484
250
1010
0.0778
0.0990
0.076
0.125
0.61
0.69

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
2.8
2.5
2.9
58.0
4980
400
696
0.253
0.323
0.086
0.334
0.37
0.42

4. Depth of laying 800 mm

4.7

kA

167
141
183

95
11.4
753
2.8
2.5
2.8
54.5
4463
500
654
0.320
0.408
0.089
0.418
0.34
0.38

2. Air temperature 40C

136
115
148

A
A
A

70
9.7
545
2.8
2.5
2.6
50.2
3862
500
603
0.443
0.565
0.092
0.573
0.30
0.34

1 Ground temperature 35C

50
8.1
375
2.8
2.5
2.5
46.5
3365
500
558
0.641
0.818
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

256
218
289

17.4

286
248
336

185
16.0
1477.5
3.4
2.5
3.3
69.7
6777
300
836
0.1640
0.2090
0.088
0.227
0.34
0.65

22.6

324
286
393

240
18.4
1938
3.4
3.15
3.5
76.9
8673
250
922
0.1250
0.1600
0.085
0.181
0.38
0.72

3. Thermal resistivity of soil 1.2C/m/W

8.9

227
192
257

150
14.6
1169
3.4
2.5
3.2
66.5
6149
300
798
0.2060
0.2630
0.090
0.278
0.32
0.60

28.2

372
321
446

300
20.6
2409
3.4
3.15
3.7
82.2
9781
250
986
0.1000
0.1280
0.083
0.152
0.42
0.79

37.6

419
368
516

400
23.3
3080
3.4
3.15
3.9
88.6
11228
250
1064
0.0778
0.0990
0.080
0.128
0.47
0.89

or any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
3.4
2.5
3.0
62.2
5498
400
747
0.253
0.323
0.093
0.336
0.29
0.55

4. Depth of laying 800 mm

4.7

kA

167
141
183

95
11.4
753
3.4
2.5
2.9
58.7
4962
500
705
0.320
0.408
0.096
0.420
0.27
0.50

2. Air temperature 40C

136
115
148

A
A
A

70
9.7
545
3.4
2.5
2.8
54.7
4364
500
656
0.443
0.565
0.100
0.574
0.24
0.45

1 Ground temperature 35C

50
8.1
375
3.4
2.5
2.6
50.7
3807
500
608
0.641
0.818
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 37

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 36

39
40

11.3

14.1

256
218
289

17.4

286
248
336

185
16.0
1477.5
4.5
3.15
3.5
76.3
8335
250
916
0.1640
0.2090
0.093
0.229
0.28
0.77

22.6

324
286
393

240
18.4
1938
4.5
3.15
3.7
82.2
9517
250
986
0.1250
0.1600
0.090
0.183
0.31
0.85

3. Thermal resistivity of soil 1.2C/m/W

8.9

227
192
257

150
14.6
1169
4.5
2.5
3.3
71.5
6813
300
858
0.2060
0.2630
0.096
0.280
0.26
0.71

28.2

372
321
446

300
20.6
2409
4.5
3.15
3.8
87.2
10596
250
1047
0.1000
0.1280
0.087
0.155
0.34
0.92

37.6

419
368
516

400
23.3
3080
4.5
3.15
4
93.7
12082
250
1124
0.0778
0.0990
0.084
0.130
0.38
1.04

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
4.5
2.5
3.2
67.6
6185
400
811
0.253
0.323
0.099
0.338
0.24
0.65

2. Air temperature 40C

4.7

kA

167
141
183

95
11.4
753
4.5
2.5
3.1
64.0
5608
400
768
0.320
0.408
0.102
0.421
0.22
0.60

4. Depth of laying 800 mm

136
115
148

A
A
A

70
9.7
545
4.5
2.5
2.9
59.8
4971
500
718
0.443
0.565
0.107
0.576
0.20
0.54

1 Ground temperature 35C

50
8.1
375
4.5
2.5
2.8
56.0
4414
500
672
0.641
0.818
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

248
227
293

17.4

282
256
341

185
16.0
1477.5
5.5
3.15
3.6
81.0
9068
250
972
0.1640
0.2090
0.098
0.231
0.24
0.90

22.6

324
295
402

240
18.4
1938
5.5
3.15
3.8
86.8
10260
250
1042
0.1250
0.1600
0.094
0.185
0.26
1.00

3. Thermal resistivity of soil 1.2C/m/W

8.9

222
201
262

150
14.6
1169
5.5
3.15
3.5
77.7
8339
300
933
0.2060
0.2630
0.101
0.282
0.22
0.84

28.2

363
329
454

300
20.6
2409
5.5
3.15
4
92.2
11436
250
1106
0.1000
0.1280
0.092
0.157
0.29
1.08

37.6

410
372
524

400
23.3
3080
5.5
3.15
4.2
98.6
12963
250
1183
0.0778
0.0990
0.088
0.133
0.32
1.21

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
175
227

120
12.9
951
5.5
2.5
3.3
72.2
6796
300
866
0.253
0.323
0.104
0.339
0.21
0.77

4. Depth of laying 800 mm

4.7

kA

167
145
188

95
11.4
753
5.5
2.5
3.2
68.7
6217
300
824
0.320
0.408
0.108
0.423
0.19
0.72

2. Air temperature 40C

136
120
153

A
A
A

70
9.7
545
5.5
2.5
3.1
64.6
5568
400
776
0.443
0.565
0.113
0.577
0.17
0.65

1 Ground temperature 35C

50
8.1
375
5.5
2.5
3
60.9
5005
500
731
0.641
0.818
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Aluminium conductorXLPE insulated
IEC: 60502-2 Steel Round WireArmoured cable
Table 39

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 38

41
42

11.3

14.1

248
227
293

17.4

282
256
341

185
16.0
1477.5
8.0
3.15
4
92.9
11047
250
1394
0.1640
0.2090
0.109
0.236
0.19
1.05

22.6

324
295
402

240
18.4
1938
8.0
3.15
4.2
98.8
12352
250
1482
0.1250
0.1600
0.104
0.191
0.20
1.15

3. Thermal resistivity of soil 1.2C/m/W

8.9

222
201
262

150
14.6
1169
8.0
3.15
3.9
89.8
10292
250
1346
0.2060
0.2630
0.112
0.286
0.17
0.98

28.2

363
329
454

300
20.6
2409
8.0
3.15
4.4
104.2
13611
250
1563
0.1000
0.1280
0.101
0.163
0.22
1.24

37.6

410
372
524

400
23.3
3080
8.0
3.15
4.6
110.6
15237
250
1659
0.0778
0.0990
0.097
0.139
0.24
1.38

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
175
227

120
12.9
951
8.0
3.15
3.8
85.7
9509
250
1286
0.253
0.323
0.116
0.343
0.16
0.91

2. Air temperature 40C

4.7

kA

167
145
188

95
11.4
753
8.0
3.15
3.7
82.2
8834
300
1233
0.320
0.408
0.121
0.426
0.15
0.85

1 Ground temperature 35

136
120
153

A
A
A

70
9.7
545
8.0
3.15
3.5
78.0
8035
300
1169
0.443
0.565
0.127
0.579
0.14
0.77

4. Depth of laying 800 mm

50
8.1
375
8.0
2.5
3.4
72.9
6577
300
1094
0.641
0.818
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

272
231
300

17.4

303
263
350

185
16.0
1477.5
2.8
2.9
59.8
3430
300
897
0.1640
0.2090
0.082
0.225
0.44
0.50

22.6

344
303
409

240
18.4
1938
2.8
3.1
65.7
4190
250
985
0.1250
0.1600
0.080
0.178
0.49
0.55

3. Thermal resistivity of soil 1.2C/m/W

8.9

240
204
268

150
14.6
1168.5
2.8
2.8
56.6
2972
400
849
0.2060
0.2630
0.084
0.276
0.40
0.45

28.2

394
340
464

300
20.6
2409
2.8
3.3
71.0
4952
250
1066
0.1000
0.1280
0.078
0.150
0.54
0.61

37.6

444
390
537

400
23.3
3080
2.8
3.5
77.5
5979
250
1162
0.0778
0.0990
0.076
0.125
0.61
0.69

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

208
181
227

120
12.9
951
2.8
2.7
52.6
2567
400
789
0.253
0.323
0.086
0.334
0.37
0.42

2. Air temperature 40C

4.7

kA

177
150
191

95
11.4
753
2.8
2.6
49.1
2216
500
736
0.320
0.408
0.089
0.418
0.34
0.38

4. Depth of laying 800 mm

145
122
155

A
A
A

70
9.7
545
2.8
2.5
45.0
1832
500
675
0.443
0.565
0.092
0.573
0.30
0.34

1 Ground temperature 35C

50
8.1
375
2.8
2.3
41.1
1491
500
616
0.641
0.818
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Aluminium conductorXLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 41

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal armour wire diameter
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Round Wire Armoured cable
Table 40

43
44

11.3

14.1

272
231
300

17.4

303
263
350

185
16.0
1477.5
3.4
3.1
64.3
3812
300
964
0.1640
0.2090
0.088
0.227
0.34
0.65

22.6

344
303
409

240
18.4
1938
3.4
3.3
70.2
4606
250
1052
0.1250
0.1600
0.085
0.181
0.38
0.72

3. Thermal resistivity of soil 1.2C/m/W

8.9

240
204
268

150
14.6
1169
3.4
3.0
61.1
3335
300
916
0.2060
0.2630
0.090
0.278
0.32
0.60

28.2

394
340
464

300
20.6
2409
3.4
3.4
75.3
5364
250
1130
0.1000
0.1280
0.083
0.152
0.42
0.79

37.6

444
390
537

400
23.3
3080
3.4
3.7
81.9
6463
250
1229
0.0778
0.0990
0.080
0.128
0.47
0.89

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

208
181
227

120
12.9
951
3.4
2.8
56.8
2880
400
853
0.253
0.323
0.093
0.336
0.29
0.55

2. Air temperature 40C

4.7

kA

177
150
191

95
11.4
753
3.4
2.7
53.3
2511
500
800
0.320
0.408
0.096
0.420
0.27
0.50

4. Depth of laying 800 mm

145
122
155

A
A
A

70
9.7
545
3.4
2.6
49.3
2105
500
739
0.443
0.565
0.100
0.574
0.24
0.45

1 Ground temperature 35C

50
8.1
375
3.4
2.5
45.5
1755
500
682
0.641
0.818
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

272
231
300

17.4

303
263
350

185
16.0
1477.5
4.5
3.3
69.6
4300
250
835
0.1640
0.2090
0.093
0.229
0.28
0.77

22.6

344
303
409

240
18.4
1938
4.5
3.4
75.3
5099
250
904
0.1250
0.1600
0.090
0.183
0.31
0.85

3. Thermal resistivity of soil 1.2C/m/W

8.9

240
204
268

150
14.6
1169
4.5
3.1
66.1
3756
300
794
0.2060
0.2630
0.096
0.280
0.26
0.71

28.2

394
340
464

300
20.6
2409
4.5
3.6
80.5
5909
250
967
0.1000
0.1280
0.087
0.155
0.34
0.92

37.6

444
390
537

400
23.3
3080
4.5
3.8
87.0
7013
250
1044
0.0778
0.0990
0.084
0.130
0.38
1.04

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

208
181
227

120
12.9
951
4.5
3.0
62.2
3317
400
746
0.253
0.323
0.099
0.338
0.24
0.65

2. Air temperature 40C

4.7

kA

177
150
191

95
11.4
753
4.5
2.9
58.6
2911
400
703
0.320
0.408
0.102
0.421
0.22
0.60

1 Ground temperature 35C

145
122
155

A
A
A

70
9.7
545
4.5
2.8
54.6
2491
500
656
0.443
0.565
0.107
0.576
0.20
0.54

4. Depth of laying 800 mm

50
8.1
375
4.5
2.6
50.6
2090
500
759
0.641
0.818
0.113
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 43

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 42

45
46

11.3

14.1

263
240
305

17.4

299
272
354

185
16.0
1477.5
5.5
3.4
74.3
4750
250
1115
0.1640
0.2090
0.098
0.231
0.24
0.90

22.6

344
312
418

240
18.4
1938
5.5
3.6
80.1
5600
250
1202
0.1250
0.1600
0.094
0.185
0.26
1.00

3. Thermal resistivity of soil 1.2C/m/W

8.9

235
213
273

150
14.6
1169
5.5
3.3
71.0
4216
300
1066
0.2060
0.2630
0.101
0.282
0.22
0.84

28.2

385
348
473

300
20.6
2409
5.5
3.8
85.5
6462
250
1282
0.1000
0.1280
0.092
0.157
0.29
1.08

37.6

435
394
545

400
23.3
3080
5.5
4.0
91.9
7606
250
1379
0.0778
0.0990
0.088
0.133
0.32
1.21

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

208
185
237

120
12.9
951
5.5
3.2
67.0
3738
300
1005
0.253
0.323
0.104
0.339
0.21
0.77

4. Depth of laying 800 mm

4.7

kA

177
154
196

95
11.4
753
5.5
3.1
63.5
3324
300
952
0.320
0.408
0.108
0.423
0.19
0.72

2. Air temperature 40C

145
127
159

A
A
A

70
9.7
545
5.5
2.9
59.2
2838
400
889
0.443
0.565
0.113
0.577
0.17
0.65

1 Ground temperature 35C

50
8.1
375
5.5
2.8
55.5
2452
500
833
0.641
0.818
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

263
240
305

17.4

299
272
354

185
16.0
1477.5
8.0
3.8
86.2
6023
250
1725
0.1640
0.2090
0.109
0.236
0.19
1.05

22.6

344
312
418

240
18.4
1938
8.0
4.0
92.1
6982
250
1842
0.1250
0.1600
0.104
0.191
0.20
1.15

3. Thermal resistivity of soil 1.2C/m/W

8.9

235
213
273

150
14.6
1169
8.0
3.7
83.1
5459
250
1661
0.2060
0.2630
0.112
0.286
0.17
0.98

28.2

385
348
473

300
20.6
2409
8.0
4.2
97.5
7926
250
1949
0.1000
0.1280
0.101
0.163
0.22
1.24

37.6

435
394
545

400
23.3
3080
8.0
4.4
103.9
9169
250
2078
0.0778
0.0990
0.097
0.139
0.24
1.38

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

208
185
237

120
12.9
951
8.0
3.6
79.0
4919
250
1580
0.253
0.323
0.116
0.343
0.16
0.91

2. Air temperature 40C

4.7

kA

177
154
196

95
11.4
753
8.0
3.4
75.3
4417
300
1506
0.320
0.408
0.121
0.426
0.15
0.85

4. Depth of laying 800 mm

145
127
159

A
A
A

70
9.7
545
8.0
3.3
71.3
3899
300
1425
0.443
0.565
0.127
0.579
0.14
0.77

1 Ground temperature 35C

50
8.1
375
8.0
3.2
67.5
3458
300
1351
0.641
0.818
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 45

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Un-Armoured cable
Table 44

47
48

11.3

14.1

256
218
289

17.4

286
248
336

185
16.0
1477.5
2.8
0.5
3
62.0
4491
300
744
0.1640
0.2090
0.082
0.225
0.44
0.50

22.6

324
286
393

240
18.4
1938
2.8
0.5
3.2
67.9
5357
250
815
0.1250
0.1600
0.080
0.178
0.49
0.55

3. Thermal resistivity of soil 1.2C/m/W

8.9

227
192
257

150
14.6
1168.5
2.8
0.5
2.9
58.8
3974
400
706
0.2060
0.2630
0.084
0.276
0.40
0.45

28.2

372
321
446

300
20.6
2409
2.8
0.50
3.4
73.2
6216
250
879
0.1000
0.1280
0.078
0.150
0.54
0.61

37.6

419
368
516

400
23.3
3080
2.8
0.8
3.6
80.9
8166
250
971
0.0778
0.0990
0.076
0.125
0.61
0.69

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
2.8
0.5
2.8
54.8
3495
400
657
0.253
0.323
0.086
0.334
0.37
0.42

2. Air temperature 40C

4.7

kA

167
141
183

95
11.4
753
2.8
0.5
2.7
51.3
3080
500
615
0.320
0.408
0.089
0.418
0.34
0.38

1 Ground temperature 35C

136
115
148

A
A
A

70
9.7
545
2.8
0.5
2.5
47.0
2599
500
564
0.443
0.565
0.092
0.573
0.30
0.34

4. Depth of laying 800 mm

50
8.1
375
2.8
0.5
2.4
43.3
2212
500
520
0.641
0.818
0.097
0.824
0.26
0.30

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

256
218
289

17.4

286
248
336

185
16.0
1477.5
3.4
0.5
3.2
66.5
4952
300
798
0.1640
0.2090
0.088
0.227
0.34
0.65

22.6

324
286
393

240
18.4
1938
3.4
0.5
3.3
72.2
5818
250
866
0.1250
0.1600
0.085
0.181
0.38
0.72

3. Thermal resistivity of soil 1.2C/m/W

8.9

227
192
257

150
14.6
1169
3.4
0.5
3.0
63.1
4387
300
757
0.2060
0.2630
0.090
0.278
0.32
0.60

28.2

372
321
446

300
20.6
2409
3.4
0.5
3.5
77.5
6706
250
930
0.1000
0.1280
0.083
0.152
0.42
0.79

37.6

419
368
516

400
23.3
3080
3.4
0.8
3.8
85.3
8777
250
1024
0.0778
0.0990
0.080
0.128
0.47
0.89

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
3.4
0.5
2.9
59.0
3887
400
708
0.253
0.323
0.093
0.336
0.29
0.55

4. Depth of laying 800 mm

4.7

kA

167
141
183

95
11.4
753
3.4
0.5
2.8
55.5
3454
500
666
0.320
0.408
0.096
0.420
0.27
0.50

2. Air temperature 40C

136
115
148

A
A
A

70
9.7
545
3.4
0.5
2.7
51.5
2974
500
618
0.443
0.565
0.100
0.574
0.24
0.45

1 Ground temperature 35C

50
8.1
375
3.4
0.5
2.5
47.5
2531
500
570
0.641
0.818
0.105
0.825
0.21
0.40

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Steel Tape Thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 6/10(12) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 47

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Steel Tape Thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=3.6kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 3.6/6(7.2) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 46

49
50

11.3

14.1

256
218
289

17.4

286
248
336

22.6

324
286
393

185
240
16.0
18.4
1477.5 1938
4.5
4.5
0.5
0.5
3.3
3.5
71.6
77.5
5503
6441
250
250
859
930
0.1640 0.1250
0.2090 0.1600
0.229 0.183
0.28
0.31
0.77
0.85

3. Thermal resistivity of soil 1.2C/m/W

8.9

227
192
257

150
14.6
1169
4.5
0.5
3.2
68.3
4931
300
820
0.2060
0.2630
0.280
0.26
0.71

28.2

372
321
446

300
20.6
2409
4.5
0.8
3.7
83.9
8185
250
1007
0.1000
0.1280
0.155
0.34
0.92

37.6

419
368
516

400
23.3
3080
4.5
0.8
3.9
90.4
9474
250
1085
0.0778
0.0990
0.130
0.38
1.04

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
171
219

120
12.9
951
4.5
0.5
3.1
64.4
4420
400
773
0.253
0.323
0.338
0.24
0.65

2. Air temperature 40C

4.7

kA

167
141
183

95
11.4
753
4.5
0.5
3
60.8
3948
400
729
0.320
0.408
0.421
0.22
0.60

1 Ground temperature 35C

136
115
148

A
A
A

70
9.7
545
4.5
0.5
2.8
56.6
3429
500
680
0.443
0.565
0.576
0.20
0.54

4. Depth of laying 800 mm

50
8.1
375
4.5
0.5
2.7
52.8
2983
500
634
0.641
0.818
0.826
0.18
0.49

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
F/km
mA/km

11.3

14.1

248
227
293

17.4

282
256
341

185
16.0
1477.5
5.5
0.5
3.5
76.5
6073
250
918
0.1640
0.2090
0.098
0.231
0.24
0.90

22.6

324
295
402

240
18.4
1938
5.5
0.5
3.7
82.3
7028
250
988
0.1250
0.1600
0.094
0.185
0.26
1.00

3. Thermal resistivity of soil 1.2C/m/W

8.9

222
201
262

150
14.6
1169
5.5
0.5
3.4
73.2
5480
300
879
0.2060
0.2630
0.101
0.282
0.22
0.84

28.2

363
329
454

300
20.6
2409
5.5
0.8
3.9
88.9
8877
250
1066
0.1000
0.1280
0.092
0.157
0.29
1.08

37.6

410
372
524

400
23.3
3080
5.5
0.8
4.1
95.3
10207
250
1144
0.0778
0.0990
0.088
0.133
0.32
1.21

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
175
227

120
12.9
951
5.5
0.5
3.2
69.0
4894
300
828
0.253
0.323
0.104
0.339
0.21
0.77

4. Depth of laying 800 mm

4.7

kA

167
145
188

95
11.4
753
5.5
0.5
3.1
65.5
4418
300
786
0.320
0.408
0.108
0.423
0.19
0.72

2. Air temperature 40C

136
120
153

A
A
A

70
9.7
545
5.5
0.5
3.0
61.4
3888
400
737
0.443
0.565
0.113
0.577
0.17
0.65

1 Ground temperature 35C

50
8.1
375
5.5
0.5
2.9
57.7
3434
500
693
0.641
0.818
0.120
0.827
0.15
0.58

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification.
Nuhas Oman is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous
development & improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Steel Tape Thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=12kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 12/20(24) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 49

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Steel Tape Thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=8.7kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1
Cond.temp 90C initial 250C max.final

Technical Data for 8.7/15(17.5) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 48

51
11.3

14.1

248
227
293

17.4

282
256
341

185
16.0
1477.5
8.0
0.5
3.9
88.4
7563
250
1327
0.1640
0.2090
0.109
0.236
0.19
1.05

22.6

324
295
402

240
18.4
1938
8.0
0.8
4.1
95.5
9589
250
1433
0.1250
0.1600
0.104
0.191
0.20
1.15

3. Thermal resistivity of soil 1.2C/m/W

8.9

222
201
262

150
14.6
1169
8.0
0.5
3.8
85.3
6940
250
1279
0.2060
0.2630
0.112
0.286
0.17
0.98

400
23.3
3080
8.0
0.8
4.5
107.3
12115
250
1610
0.0778
0.0990
0.097
0.139
0.24
1.38
410
372
524
37.6

300
20.6
2409
8.0
0.8
4.3
100.9
10686
250
1513
0.1000
0.1280
0.101
0.163
0.22
1.24
363
329
454
28.2

for any other condition(s) please refer to the appropriate table for recommended installation data.

6.6

197
175
227

120
12.9
951
8.0
0.5
3.6
81.0
6287
250
1215
0.253
0.323
0.116
0.343
0.16
0.91

4. Depth of laying 800 mm

4.7

kA

167
145
188

95
11.4
753
8.0
0.5
3.5
77.5
5759
300
1163
0.320
0.408
0.121
0.426
0.15
0.85

2. Air temperature 40C

136
120
153

A
A
A

70
9.7
545
8.0
0.5
3.4
73.5
5167
300
1102
0.443
0.565
0.127
0.579
0.14
0.77

1 Ground temperature 35C

50
8.1
375
8.0
0.5
3.3
69.7
4657
300
1046
0.641
0.818
0.134
0.829
0.12
0.70

mm2
mm
kg/km
mm
mm
mm
mm
kg/km
m
mm
ohm/km
ohm/km
ohm/km
ohm/km
F/km
mA/km

Disclaimer: The contents of this document are purely for information and guidance only. User should not take these data as specification. Nuhas Oman
is in no way responsible for any loss or damage, direct or consiquential, due to reliance of the data.In its efforts for continuous development &
improvement Nuhas Oman may change any or whole of the data without notice.

Assumption:

Nominal cross sectional area of conductor


Conductor diameter (Approx)
Weight of conductor (Approx)
Nominal insulation thickness
Nominal Steel Tape Thickness
Nominal Outer sheath thickness
Overall Diameter (Approx)
Weight of cable (Approx)
Standard packing length ( 5%)
Minimum bending radius during installation
DC resistance at 20C (max)
AC resistance at 90C (approx)
Reactance at 50 Hz (approx.)
Impedance at 50 Hz approx.
Capacitance at 50 Hz
Charging current /phase at Uo=18kV,50Hz (approx)
Continuous Current Rating at cond temp. 90C max.
1. Laid direct in ground,
2. Laid into ducts
3. Laid in air in trefoil touching
Short circuit current rating for 1 sec
Cond.temp 90C initial 250C max.final

Technical Data for 18/30(36) kV, Three Core Aluminium conductor XLPE insulated
IEC: 60502-2 Steel Tape Armoured cable
Table 50

GENERAL CABLE TECHNICAL DATA


& RATING FACTORS

52

Table 51
Recommended minimum bending radius
XLPE cables up to 22 kV
Type of cables
Single core

Minimum bending radius


During laying

Adjacent to joints/termination

20D
15D

15D
12D

15D
12D

12D
10D

Cable placed in position

Laid in ducts

laid in air

or adjacent to joints/termination

20D
15D

20D
15D

15D
12D

1. Unarmoured
2. Armoured
3 core
1. Unarmoured
2. Armoured
33 kV - 132 kV
1. Unarmoured
2. Armoured

Table 52
Rating Factors For Variation in Air Ambient Temperature
Air Temperature

20

25

30

40

45

50

55

60

Rating factors

1.2

1.16

1.12

1.00

0.96

0.89

0.82

0.76

Table 53
Rating Factors For Variation in Ground Temperature
Ground Temperature
Rating factors

15

20

30

35

40

45

50

1.15

1.12

1.03

1.00

0.95

0.89

0.86

Table 54
Rating Factors For Variation in Depth of Laying
Depth of laying in mm

1.1 kV

upto 11 kV

22 & 33 kV

550
750
900
1050
1200
1500

1
0.98
0.97
0.95
0.93
0.91

1
1
0.98
0.97
0.95
0.94

1
1
1
0.98
0.97
0.95

52

Table 55
Rating Factors For Variation of Thermal Resistivity of Soil
Voltage rating of cables

Thermal Resistivity of Soil in C Cm/kW


100
1.19
1.18
1.12

up to 3.3 kV
up to 22 kV
33 kV

120
1.04
1.08
1.06

200
0.87
0.89
0.89

250
0.82
0.85
0.85

300
0.75
0.74
0.74

FORMATION OF CABLES

Table 56
RATING FACTORS FOR SINGLE CORE CABLE IN
TREFOIL CIRCUITS LAID ON OPEN RACKS IN AIR
No of rackjs
1
2
3
6

Cables touching
spaced by 15 cm
spaced by 30 cm

No of circuits
1.00
1.00
1.00
1.00

300 mm

Arrangement 1

1
2
3
6

1
1.00
1.00
1.00
1.00

No. of cables per rack


2
0.98
0.95
0.94
0.93

1
1.00
1.00
1.00
1.00

No. of cables per rack


2
0.84
0.80
0.78
0.76

No of racks
300
mm

Arrangement 2

1
2
3
6

6
0.93
0.90
0.89
0.87

3
0.69
0.72
0.76

53

6
0.54
0.59
0.65

9
0.73
0.69
0.68
0.66

8
0.5
0.54
0.62

10

0.78
0.81
0.85
0.91
0.93

0.68
0.71
0.76
0.84
0.87

0.53
0.57
0.64
0.79
0.85

0.48
0.53
0.60
0.78
0.82

0.50
0.50
0.58
0.72
0.76

Table 61
RECOMMENDED DUCT SIZES
Cable diameter in mm
up to 65 mm
over 65 upto 90 mm
over 90 upto 115 mm

No of cables in group
2
0.79
0.82
0.86

0.43
0.46
0.50

No of circuits in group

Cables touching
spaced by 15 cm
spaced by 30 cm
spaced by 45 cm
spaced by 60 cm

Table 58
RATING FACTORS FOR GROUPING OF MULTICORE CABLES
LAID DIRECT IN GROUND, IN HORIZONTAL FORMATION

Cables touching
spaced by 15 cm
spaced by 30 cm

0.51
0.55
0.60

Spacing

9
0.92
0.89
0.88
0.86

6
0.75
0.71
0.70
0.68

0.60
0.64
0.69

Table 60
RATING FACTORS FOR GROUPING OF SINGLE CORE CABLES
LAID IN TREFOIL CIRCUITS
LAID DIRECT GROUND IN HORIZONTAL FORMATION

0.96
0.93
0.92
0.90

Table 57
RATING FACTORS FOR MULTICORE CABLES LAID
ON OPEN RACKS IN AIR
No of racks

Table 59
RATING FACTORS FOR GROUPING OF MULTICORE CABLES
LAID DIRECT IN GROUND IN TIER FORMATION

10
0.46
0.51
0.59

Nominal duct diameter


100
125
150

Table 62
MAXIMUM RECOMMENDED PULLING TENSIONS
Using pulling eye on the conductor
Copper
Aluminium stranded
Using pulling on steel Wire armour

0.070 kN/mm2
0.050 kN/mm2
0.005 kN/mm2

Using stocking grip

0.0035D2 kN

54

55

56

57

/6)"40."/--$
10#PY 1PTUBM$PEF 
3VTBZM*OEVTUSJBM&TUBUF 4VMUBOBUFPG0NBO
5FM   'BY 
&NBJMNBSLFUJOH!OVIBTPNBODPN8FCTJUFXXXOVIBTPNBODPN


".FNCFSPGUIF"M#BIKB(SPVQ

"/*40$0.1"/:
/6.,5%#+3FW
%BUF