You are on page 1of 4

EMERGENCY REPAIR CONSOLE

What is Emergency Repair Console?


ERConsole is a special application created to recover or add
additional IP address on Infinet Wireless units. Additionally,
ERConsole is a tool to reset Infinet Wireless units to factory default
configuration
Required software
Java Runtime Environment should be installed. Please download it if
it is not installed: http://www.java.com/en/download/
Download ERConsole from our ftp site:
ftp://ftp.infinet.ru/pub/Utils/EmergenceRepairConsole/ERConsole.zip
Network Requirements

1. Please set static IP address to network interface connected to Infinet Wireless unit or to switch
connected with Infinet Wireless unit (Please don't use Cisco switch - reasons will be described later).
Sample connection scheme shown on picture below.

Direct connection

Connection through
switch

PC or MAC

Simple L2
switch

IW
Legend

IW

PC or MAC

Ethernet physical cable connection


ERP Layer3 broadcast

http://www.infinetwireless.com

EMERGENCY REPAIR CONSOLE


2. Please set default gateway address to the same network interface configuration connected to Infinet
Wireless unit or to switch connected with Infinet Wireless unit. Example is on picture below.

3. Disable any anti-virus, firewall software running on your computer

We recommend to use simple unmanaged switch as intermediary unit between your PC


and Infinet unit. It is essential to reboot Infinet unit each time to activate Emergency
Repair Protocol on Infinet unit, therefore the switch would prevent your PC Ethernet
interface from flapping Down/Up. Using Cisco Catalyst switches for unit recovery is
not recommended due to a known issue port mode negotiation delay.

http://www.infinetwireless.com

EMERGENCY REPAIR CONSOLE


Step-by-step instruction to obtain IP address via ERConsole operation
1. Connect network Ethernet cables between Infinet Wireless unit and your computer

2. Extract zip archive, run the ERConsole.jar (in Linux you have to set executable bit)
The ERConsole window should be seen now, like on right
picture

3. Power of Infinet unit and power up it again in few


seconds.
ERConsole and Infinet units exchanges information
ONLY during bootup process, therefore each time you
need to read units IP address or change it, or reset units
configuration to factory default - the Infinet units should
be rebooted.

4. Wait about 30 second and ERConsole screen should


receive updates from the unit.
Serial number, ip address and network mask should appear in ERConsole screen. Like on the upper
picture.
Step-by-step instruction to add additional IP address via ERConsole operation

In order to assign additional IP address to the unit please obtain units IP address and serial
number first (it was described in preceding
instruction)
5. In the ERConsole window click to the selected units
serial number

6. Click to + at the bottom of the list. Please see picture


of Infinet Emergency Repair Console to the right

7. New window would open - Please set additional ip


address with netmask. Please see New task picture

8. Don't forget to click OK after you've set additional IP


address and password

9. Power of Infinet unit and power up it again in few seconds


ERConsole and Infinet units exchanges information ONLY during bootup
process, therefore each time you need to read units IP address or change it, or
reset units configuration to factory default - the Infinet units should be
rebooted

10. Wait about 30 second and additional IP address will be assigned to eth0
physical port

11. Please add IP address from the same network subnet to your PC and access the unit. ERC would not
show newly assigned IP address. Only IP address saved to configuration for eth0 can be obtained via
ERC.
12. Log into unit using additional IP address assigned to the unit. Dont reboot the unit now, cause
additional IP address is temporal until units restart or until new configuration save.

http://www.infinetwireless.com

EMERGENCY REPAIR CONSOLE


Step-by-step instruction to reset configuration of Infinet unit to factory defaults
In order to reset configuration of the unit please obtain units IP address and serial number first (it was
described in preceding instruction)

1. In the ERConsole window click to the selected units serial number


2. Click to + at the bottom of the list. Please see picture of Infinet Emergency Repair Console to the
right

3. New window would open - Please select Reset configuration. Please see New task picture
4. Call Infinet Wireless Technical support:
+7 343 253 15 33
or open new case
http://support.infinetwireless.com
or email to support@infinetwireless.com
for Factory Password for your unit.
You should provide units serial number

5. Please paste or enter Factory Password


obtained from Infinet Wireless Technical
support into Factory Password field. Check
picture on the right

6. Don't forget to click OK after you've inserted Factory


Password

7. Power of Infinet unit and power up it again in few seconds


ERConsole and Infinet units exchanges information ONLY during
bootup process, therefore each time you need to read units IP address or change it, or reset units
configuration to factory default - the Infinet units should be rebooted

8. Wait about 30 second and unit would start in special EMERGENCY mode with IP address
10.10.10.1 255.255.255.0

9. Please log in to unit (using telnet or web) and Reset the units configuration to factory defaults:
CLI> config clear; restart yes
Web> Basic Settings > Reset to Factory Defaults

10. Please repeat step 9.


11. Please modify network settings on your PC to match default IP address of Infinet unit.
Infinet unit default IP address is 10.10.10.1 netmask 255.255.255.0

12. Connect to IP address 10.10.10.1 using Web browser or telnet protocol

http://www.infinetwireless.com

You might also like