Professional Documents
Culture Documents
412-6
ARI certification
Daikin water heating and
booster coils are certified in
accordance with the forced circulation air cooling and air heating
coil certification program, which
is based on ARI Standard 410.
Note: Special application coils may be outside the scope of
ARI Standard 410.
Contents
SelectTOOLSTM..................................................................3
ARI certification..................................................................3
Nomenclature ....................................................................4
Standard availability chart ..................................................5
Circuiting arrangements.....................................................6
Design features..................................................................7
General specifications 5W & 5B coils............................8
Application recommendations............................................9
Cleanable coils ..................................................................9
Sample coil selection .......................................................10
Nomenclature
5W H - 10 02 C - 033.00 - 090.00
COIL TYPE
Water: 5M, 5W, 5K, 5P, 5Q
Booster: 5B
CIRCUITING
Water:
Q = 1/4 Serpentine
H = 1/2 Serpentine
L = 3/4 Serpentine
S = 1
Serpentine
M = 1-1/2 Serpentine
D = 2
Serpentine
B = 3
Tube Center
Booster:
S = 1 Circuit
D = 2 Circuit
B = 3 Tube Center
FIN DESIGN
B = 01, 02, 03 & 04 ROW E-F5
C = 01, 02, 03 & 04 ROW HI-F5
HOT WATER
COIL MODEL
5MQ 5MH 5MS 5WB 5WQ 5WH 5WL 5WS 5WM 5WD 5KQ 5KH 5KS 5QQ 5QH 5QS 5PQ 5PH 5PS
SERPENTINE CIRCUIT
1/4
1/2
1*
1/4
1/2
3/4
ROWS
1,2
1,2
1,2,
3,4
3,4 2,3,4
CONNECTION
LOCATION
***
12- 54
12-54
FINS
COPPER
1/4
1/2
1/4
1/2
1,2
1,2
1,2
5BS
5BD
1
1
1
Feed* Feed Feed
1,2
1,2
Same End
Same End
12-42
6-24
12-141
6-60
E-F
.0075
.0095
.006
.0075
.0095
6,7,8,9,10,11,12,13,14
1.5
6,7,8,9,10,
11,12,13,14
6,7,8,9,10,11,12,13,14
5/8
FACE C/C
HEADERS
1/2
5BB
HI-F
DIAMETER
COPPER
1/4
12-141
SPACING
(FPI)
TUBING
1-1/2" INCREMENT
FINNED LENGTH
ALUMINUM
1-1/2
FIN HEIGHT
3" INCREMENT
FIN TYPE
HOT WATER
(BOOSTER)
5/8
3.0
1.5
5/8
1.5
3.0
1.5
.020*
.025
.035
.049
STANDARD
MAT'L**
Copper Tubing
Copper Tubing
Threaded Copper
Fittings
MAXIMUM STD.
250 Psig
250 Psig
250 Psig
OPERATING LIMITS
300 F
300 F
300 F
z Feature Available
* .020 is a nominal tube thickness
** Optional header materials are available; consult your representative.
*** Available in 6 increments.
Flexibility
Along with the standard offerings, optional materials and special configurations are provided to meet many different specifications.
Extra long fin lengths, intermediate tube supports, along with a wide variety of tube wall and fin thicknesses are available. Casings
can be constructed of galvanized steel, aluminum, stainless steel or copper. Optional connection materials such as steel, Monel,
red brass or copper (sweat) are offered along with butt-weld, victaulic or flange type connections. Coil coatings can be phenolic or
Electro Fin.
These are just a few of the options and specials that can be provided. Consult your local representative for your special coil
requirements.
*Note: Special application coils may be outside the scope of ARI standard 410.
Circuiting arrangements
Hot water coil circuitings
Type 5WB, 5WQ, and 5WH coils are designed to produce
high capacity with limited water quantity. High performance is
achieved by the increased water velocity obtained from the
circuiting of these coil types.
5WQ
1/4 SERPENTINE (1 ROW)
5WH
1/2 SERPENTINE (2 ROW)
5WS
1 (SINGLE) SERPENTINE (2 ROW)
5WH
1/2 SERPENTINE (1 ROW)
5MS
1 (SINGLE) SERPENTINE (2 ROW)
Type 5BB and 5BS coils are single circuited and are available in one and two rows deep. Type 5BD coils are double
circuited and are available in two rows deep.
5BB
SINGLE FEED
(1, 2 ROW)
5BS
SINGLE FEED
(1, 2 ROW)
5BD
DOUBLE FEED (2 ROW)
Design features
A variety of fin spacings
Standard water heating and booster coils are available with
06, 07, 08, 09, 10, 11, 12, 13 or 14 fins per inch. The wide
variation in fin spacing permits accurate balancing of coil
capacities with the design load.
Flanged casings
Double flanged galvanized steel casings on all water heating coils provide greater strength and better support for
easier coil stacking. Moving and handling operations are
simplified by the heavy coil casings.
Top and bottom casing flanges are turned back to form two
channel sections in a "box" shape, providing maximum
strength and durability.
Hot water booster coils can be furnished with flanges for
slip-and-drive fasteners or full flanged casings for standard
installations.
(3) Headers
Extra-heavy, seamless copper tubing. Tube holes
are intruded to provide maximum brazing surface
for added strength. Header end caps are heavygauge, die-formed copper. Cupro-nickel headers
and Monel end caps are available for special
applications. Headers are not used on type 5B
booster coils.
(4) Connections
Unique hand connections are provided for lefthand or right-hand applications. Universal connections are also available for most coils.
Standard water coil connections:
Steel male pipe supply and return connections.
Other materials available on request. (Red
brass connections are recommended for coils
used with non-ferrous piping.)
Booster coil connections:
Wrought copper, 1/2" NPT, supply and return
connections.
(5) Brazing
All joints are brazed with copper brazing alloys.
(6) Casing
Die-formed, heavy-gauge, continuous galvanized
steel with reinforced mounting flanges (other
materials available on request). Intermediate tube
sheets position the core assembly on the larger
standard water coils to prevent damage in handling and shipment.
Vents
Furnished on all standard water coils.
Tests
Complete coil tested leak free under warm water
containing special wetting agent at 315 psig air
pressure.
Operating conditions
Standard coils are suitable for use up to 250 psig
and temperatures up to 300 F for 5W and 5B
coils. High pressure coils are suitable for use up to
400 psig and 400F
Application recommendations
1. Piping should be in accordance with accepted industry standards.
2. When drainable coils are desired, tubes should be
installed in a horizontal position. Use a spirit level. If
the tubes cannot be installed level, special drain
headers are available on request.
3. Connect the water supply to the leaving air side and
the water return to the entering air side of the coil.
Connecting the supply and/or return in any other
manner will result in a reduced performance.
4. Hot water coils are not normally recommended for
use with entering air temperatures below 40 F;
however, special high pressure water coils have
been used very successfully on high temperature
hot water jobs with low entering air temperatures
when correctly controlled. No control system can be
depended on to be 100% safe against freeze-up
with water coils. Glycol solutions or brines are the
only freeze-safe media for operation of water coils
for low entering air conditions.
5. When fresh and return air are to be heated by a hot
water coil, care should be used in the design of the
ductwork to provide thorough mixing before the air
enters the coil.
The return air should always enter the bottom of the
duct. Fresh air should enter the top of the duct. The
greater the distance between the point of mixing and
entrance to the coil, the better the application.
Fin Type
Hl-F5
5/8
HI-F
Hi-Efficiency
E-F5
5/8
E-F
Energy
Efficiency
Application
Gives highest heat transfer rate for a given amount of surface.
Smoother fin corrugation than the Hl-F5 results in a lower air pressure drop and
lower fan bhp requirements. The cost of additional surface can be amortized by
the kw savings.
Cleanable coils
5W type water coils are also offered in a cleanable tube configuration. The cleanable coils are identical to 5W coils with
the addition of removable plugs in the header(s) to facilitate
tube cleaning. Type 5PQ, 5PH and 5PS coils have removable
plugs on the coil connection end only.
7.
Solution:
1. Determine coil face area:
24 x 72 = 12.0 sq. ft.
144
30
36.7
.818
9.
36.7F
Since we have assumed a 1-row coil:
Max. Rft = 1
=
1
= 1 = .606
Mt x FPM
.33 x 500
1.65
100
100
30F
No. of Feeds =
GPM
=
16.0 =
4
GPM/feed
4
See Table 2, page 10, under 24 FH dimension to determine
which coil type is available for the number of feeds desired
(or closest to desired). Type 5WB and 5WQ 1-row coils have
four feeds. Check type 5WB first because this is the most
economical coil.
Rf2 must equal Rft - Rf1 = (.606 - .183) = .423 or less for a
1-row type 5WB coil to meet the requirements. Enter Rf2
curve for type 5BB and 5WB coils, page 14 at 500 FPM
face velocity and find that Rf2 = .42 fin series 12, which
meets the requirements.
10. Final coil selection:
The final selection is a 5WB -1201C-24 x 72 coil.
12
15
18
21
24
30
36
42
48
54
60
66
72
78
84
90
*6
*9
12
0.5
0.8
1.0
0.6
0.9
1.3
0.8
1.1
1.5
0.9
1.3
1.8
1.0
4.5
2.0
1.3
1.9
2.5
1.5
2.3
3.00
1.8
2.6
3.5
2.0
3.0
4.0
2.2
3.4
4.5
2.5
3.7
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
1.6
1.9
2.3
2.19
2.62
3.06
2.5
3.0
3.5
3.1
3.8
4.4
3.8
4.5
5.3
4.9
5.3
6.1
5.0
6.0
7.0
5.6
6.7
7.9
6.2
7.5
8.7
6.9
8.2
9.6
7.5
9.0
10.5
8.1
9.7
11.4
8.7
10.5
12.2
9.4
11.2
13.1
10.0
12.0
14.0
10.6
12.7
14.9
11.2
13.5
15.7
11.9
14.2
16.6
12.5
15.0
17.5
40.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
5.6
6.3
6.8
7.5
7.9
8.8
9.0
10.0
10.1
11.2
11.2
12.5
12.4
13.7
13.5
15.0
14.6
16.2
15.7
17.5
16.9
18.7
18.0
20.0
19.1
21.2
20.2
22.5
21.4
23.7
22.5
25.0
8.3
9.0
9.6
10.5
11.4
11.0
12.0
13.0
12.4
13.5
14.6
13.7
15.0
16.2
15.1
16.5
17.9
16.5
18.0
19.5
17.9
19.5
20.1
19.2
21.0
22.7
20.6
22.5
24.4
22.0
24.0
26.0
23.4
25.5
27.6
24.7
27.0
29.2
26.1
28.5
30.9
27.5
30.0
32.5
12.3
15
18
21
24
27
30
33
36
39
42
108
114
120
126
132
138
141
14.0
15.7
17.5
19.2
21.0
22.7
24.5
26.2
28.0
29.7
31.5
33.2
35.0
45
15.0
16.9
18.8
20.6
22.5
24.4
26.3
28.1
30.0
31.9
33.8
35.7
37.5
39.4
41.3
43.1
44.1
48
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
38.0
40.0
42.0
44.0
46.0
47.0
51
19.1
21.3
23.4
25.5
27.6
29.8
31.9
34.0
36.1
38.3
40.4
42.5
44.6
46.8
48.9
49.9
54
20.3
22.5
24.8
27.0
29.3
31.5
33.8
36.0
38.3
40.5
42.8
45.0
47.3
49.5
51.8
52.9
In addition to the standard fin lengths listed above, any required length can be supplied. * Standard on Type 5B coils
10
96
EXAMPLE:
To convert 15,900 CFM of air at
95F and at 3,000 feet altitude to
standard conditions:
CFM of Standard Air
= CFM of Specified Air x FT x FA
= 15,900 x 0.955 x 0.896
= 13,600
1.30
1.25
1.25
1.20
1.20
1.15
1.15
1.10
1.10
1.05
1.05
1.00
1.00
0.95
0.95
0.90
0.90
0.85
0.85
0.80
0.80
0.75
0.75
0.70
0.70
0.65
100 125 150 175 200 225 250 275 300 325 350
0.65
-50 -25
25
50
75
TEMPERATURE (F)
Where:
FT = Temperature Conversion
Factor from Figure 1
FA = Altitude Conversion
Factor from Figure 2
Figure 2.
1.025
1.025
1.000
1.000
0.975
0.975
0.950
0.950
0.925
0.925
0.900
0.900
0.875
0.875
0.850
0.850
0.825
0.825
0.800
0.800
0.775
0.775
0.750
0.750
0.725
0.725
0.700
-500 0
500
1500
2500
3500
4500
5500
6500
7500
0.700
8500
11
General formulas
TOTAL BTUH AIR SIDE:
Total BTUH = 1.09 x SCFM x (Lvg. Air Dry Bulb -Ent. Air
Dry Bulb)
Where: 1.09 = (Sp Ht. of Air at 70F) x (min./hr.) x Density
Std. Air
.242 = Sp. Ht. of Moist Air at 70F
60 = min./hr.
.075 = Density Std. Air in Lbs./Cu.Ft.
WATER VELOCITY:
5/8" Tubes: Water Velocity FPS =
Total BTUH
1.07 X GPM
FACE AREA:
SCFM
FA =
FACE VELOCITY: FV =
100
ROWS
5BB, 5BS
FH DIMENSIONS (INCHES)
6
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
1, 2
5BD
5MS
30
32
34
36
18
5MH
1, 2
10
11
12
13
14
15
16
17
5MQ
5WB, 5WQ
2.5
3.5
4.5
5.5
6.5
5WH
1, 2, 3, 4
10
11
12
13
14
15*
16*
17*
18*
5WB
10
11
12
13
14
5WL
3, 4
10
12
13
15
16
18
19
21
22
24
25
27
5WS
10
12
14
16
18
20
22
24
26
28
5WS
3, 4
10
12
14
16
18
20
22
24
26
28
30
32
34
36
5WM
12
15
18
21
24
27
30
33
36
39
42
45
48
51
54
5WD
16
20
24
28
32
36
40
44
48
52
56
60
64
68
72
12
13
14
.8
7.0
.7
6.0
5.0
.6
4.0
FIN
SE
RIE
S
.5
Rf2
FIN
SE R
I
.4
3.0
FIN S
E
10
ES
12
RIES
14
.3
2.0
.2
300
400
600
500
800
1000
1500
1.5
1.0
.8
.9
.8
AV
TE ERA
MP GE
ER W
AT AT
UR ER
E,
F
10
0
.7
.6
.5
.7
.6
FIN
S
13
0
ER
IES
.5
Rf2
.4
.4
18
0
.3
FIN
S
23
0
30
0
FIN S
E
.2
.2
.4
.6
.8
1.0
1.2
ALL
ALL OTHERS
OTHERS
.1
.2
.3
.4
.5
.6
300
Rf1
ER
I ES
08
FIN
SER
IES
10
FIN
SE R
IES
12
.3
.2
5NB
5 5BB
BB &&5WB
06
500
RIES
14
800
1000
1500
NOTE: Heat transfer values for odd fin spacings may be found by
interpolation.
15
HI-F5
2.5
1.2
2.0
1.0
.9
.8
.7
1.8
1.6
1.4
4.0
14
12
10
08
1.2
2.0
1.6
2.0
.9
1.4
1.8
.8
1.2
1.6
.7
1.0
.6
.9
.3
.8
.5
.2
3.0
1.8
1.0
.4
4.0
06
FIN
SERIES
.6
.5
3.0
5.0
.7
.6
.4
.5
1.4
1.2
1.0
.9
.8
.7
.6
.3
.4
.5
.3
.2
.4
.10
.09
1.4
ROWS
3
4
.3
.08
.2
.07
.06
.10 FIN
SERIES
.05 .09
14
.08
12
.04
.07
10
.06
.03
08
.2
.10
.09
.08
.05
.07
06
.04
.02
200
300
400
500
.10
.09
.06
.08
.052
.07
1500
16
1.2
8.0
7.0
1.1
6.0
1.0
5.0
FI
N
SE
RI
ES
.9
4.0
06
.8
Rf2
FIN
3.0
SE
RI
ES
.7
FIN
S
.6
08
ER
IES
10
2.0
FIN
S
.5
ERI
ES
FIN
S
.4
GPM / Feed
1.5
12
ERIE
S
14
.3
.2
300
1.0
400
.9
600
500
800
1000
1500
1000
1500
.8
AV
TE ERA
MP GE
ER W
AT AT
UR ER
E,
F
10
0
.7
.6
1.2
1.1
.5
13
0
1.0
.4
.9
18
0
.3
.8
23
0
Rf2
FI
N
.7
30
0
SE
RI
ES
06
.6
.2
5NB
5 5BB
BB &&5WB
.2
.4
.6
.8
1.0
1.2
ALL
ALL OTHERS
OTHERS
.1
.2
.3
.4
.5
.6
FIN
.5
Rf1
FIN
.4
FIN
S
400
500
08
SE
RIE
S
FIN
S
.3
.2
300
SE
RI
ES
ERI
ES
10
12
ERI
ES 1
600
800
17
1.4
E-F5
2.5
1.2
2.0
1.0
.9
.8
.7
1.8
1.6
1.4
1.2
.6
1.0
.5
.9
ROWS
3
4
4.0
FIN
SERIES
12
2.0
10
1.8
08
1.6
06
1.4
1.8
1.2
1.6
.7
1.0
.6
.9
.3
.8
.5
.2
4.0
3.0
14
.8
.4
3.0
5.0
.7
.6
.4
.5
2.0
1.4
1.2
1.0
.9
.8
.7
.6
.3
.4
.5
.3
.2
.4
.10
.09
ROWS
1
2
.3
.08
.2
.07
.06
.10
.05 .09
.2
.08
.04
.07
.10
.06
.09
.03
.08
.05
.02
.07
.04
200
300
400
500
.10
.09
.06
.08
.052
.07
1500
18
12
.3
24
.1
.5
36 8
4 0
6
.2
.4
.1
.2
.3
.4
.2
.4
.5
L)
(F
.5
.4
TH
G
.4
.3
N
LE
.5
.3
.5
ED
NN
I
F
.2
.3
3
5
2
5
1
10
3
5
10
20
4
.5
30
.6
20
40 50
10
5
10
20
10
30
20
30
40 50
40 50
30
40 50
20
40 50
.7 .8
30
10
20
30
2 ROW
5BB
5BD
5BS
5BS
NN
FI
H
IG
E
H
1 ROW
H)
(F
10
16
12
24
21
18
15
19
20
ROWS
96
120
48
60
72
36
24
12
144
N
N
FI
ED
NG
LE
TH
(F
L)
10
4 5
.5
.5
11
.5
20
10
.5
30
40
20
100
200
100
30
30
4 5
40
5MQ - 148ROW
& 54"48 & 54"
.5
40 50
3.5 4
.5
10
4 5
.5
20 25
10
30 40 50
20
10
10
20
10
50
.5
.5
2
10
.5
.5
10
30
H
(F
40
20
100
20
50
20
10
4 5
30 40
18 20
20
12
15
10 15 20
30
100
16
30
20
10
30 35
10
20
10
4 5
30 40 50 60
4 5
10
10
30 40 50 60
10
4 5
H
G
EI
4 5
4 5
4 5
20
20
N
FI
4 5
.5
200
280
18 1
2 4
2 7
2 0
3 3 39
3 6 42
3
48 1
45 5
54
12
24
NN
FI
36 8
4 0
6
72 6 20
9 1 44
1
ED
N
LE
.1
TH
G
L)
(F
4 5
.3
10
.4 .5
.2
4 5
.3
20
.4 .5
60
20
10
30 40 50
10
4 5
30
.5
.2
.1
20
4 5
FH = 21-54
FH = 12-18*
FH = 45-54
FH = 33-42
FH = 21-30
FH = 12-18
FH = 45-54
FH = 12-142
FH = 45-54
FH = 12-142
.5
.6
.5
.5
8 9 10
20
40
50
2
2
100
ED
18
)
H
(F
30 40 50
10
10
18
200
18
20 30
10
20
10
10
10
10
10
30 40 50
T
H
G
I
HE
20
20
4 5
10
10
4 5
4 5
4 5
4 5
4 5
4 5
4 5
NN
FI
4 5
10
4 5
10
4 5
20
16
20
18
20
30
.5
.5
.5
.5
.5
FH = 39-54
5WH
FH = 12-36
5WL
5WS
5WM
5WD
.5
300
400
18
21
24
27
30
33
36
39
425
4 48
51
54
15
12
ROWS
21
2.50
3.00
0.75
B
0.75
RETURN
AIR
FLOW
ROW
MODEL
TYPE
CONN
SIZE
5WH, 5WQ
1-1/2
2.75
2.67
5WB
1-1/2
2.75
3.42
5WH, 5WS
2-1/2
3.38
3.17
5WB
2-1/2
3.38
3.92
RH
SUPPLY
E
1.50
FINNED LENGTH (FL)
2.50
1.50
5.00
1.50
1.50
A MAX
A MAX
Figure 13. 5K, 5P, 5Q cleanable coils - 1- and 2 - row (12 to 42 fin height)
VENT
2.50
3.00
0.75
ROW
MODEL
TYPE
CONN
SIZE
5PH, 5PQ
1-1/2
2.75
2.67
5QH, 5QQ
1-1/2
2.75
2.67
5KH, 5KQ
1-1/2
2.75
2.67
5PH, 5PS
2-1/2
3.38
3.17
5QH, 5QS
2-1/2
3.38
3.17
5KH, 5KS
2-1/2
3.38
3.17
B
0.75
RETURN
AIR
FLOW
RH
SUPPLY
E
1.50
FINNED LENGTH (FL)
2.50
1.50
A MAX
1.
A MAX
TYPE
1-ROW 2-ROW
5WB
5WS
5KS
5PS
5QS
TYPE
1-ROW 2-ROW
2-1/2
5WQ
5KQ
5PQ
5QQ
SPLIT HEADER ON
ONE-ROW COILS ONLY.
SLUG DIVIDING HEADER
ON TWO-ROW COILS
EXCEPT 5WB TWO-ROW.
5WH
5KH
5PH
5QH
2-1/2
SPLIT HEADER(S) ON
ONE-ROW COILS ONLY.
SLUG(S) DIVIDING HEADER
ON TWO-ROW COILS.
5
CONN.
END
22
1.50
5.00
5WB
5WH
5KH
5PH
5QH
OPP.
CONN.
END
5
CONN.
END
OPP.
CONN.
END
VENT
VENT
3.00
EXT. TYP.
0.75
A MAX
0.75
RETURN
RETURN
G
B
LH
E
AIR
FLOW
AIR
FLOW
SUPPLY
M
RETURN
W + 3.00
W
RH
1.50
SUPPLY
L
DRAIN
DRAIN
DEPTH
DEPTH
1.50
A MAX
LEFT HAND
AIR FLOW COIL
RIGHT HAND
AIR FLOW COIL
1.50
1.25 MAX OVER
RETURN BENDS
.375 DIA. HOLES
IN CORNERS
R. H. RETURN
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
5WH COILS
ROW
DEPTH
6.00
7.50
1.70
1.80
1.70
1.80
6.05
6.05
5.30
6.05
6.30
6.30
5.55
6.30
6.05
6.05
5.30
6.05
3.05
2.30
6.30
6.30
5.55
6.30
3.30
2.55
AIR FLOW
W DIMENSIONS
N/A
HORZ.
AIR
FLOW
12.00 - 36.00
39.00 - 54.00
12.00 - 36.00
VERT.
AIR
FLOW
39.00 - 54.00
N/A
CONN
SIZE
1-1/2
*3.00 2.30
2.30
12.00 - 36.00
1-1/2
*3.00 2.30
12.00 - 36.00
*3.50 2.55
2.55
39.00 - 54.00
*3.50 2.55
39.00 - 54.00
23
5WL COILS
ROW
DEPTH
CONN
SIZE
6.00
1-1/2
3.00
2.30
4.55
3.80
2.30
1.70
1.70
12.00 36.00
6.00
3.50
2.55
4.80
4.05
2.55
1.70
1.70
39.00 42.00
7.50
2-1/2
3.63
2.80
5.05
4.30
2.80
2.20
1.80
45.00 54.00
7.50
1-1/2
3.00
2.30
4.55
4.55
2.30
1.80
1.80
12.00 18.00
7.50
3.50
2.55
4.80
4.80
2.55
1.80
1.80
21.00 30.00
7.50
2-1/2
3.63
2.80
5.05
5.05
2.80
1.80
1.80
33.00 54.00
5WS COILS
CONN
SIZE
1-1/2
2.75
2.30
4.55
4.55
2.30
12.00 - 18.00
3.25
2.55
4.80
4.80
2.55
21.00 - 30.00
2-1/2
3.38
2.80
5.05
5.05
2.80
33.00 - 42.00
3.80
3.06
5.36
5.36
3.06
45.00 - 54.00
ROW
DEPTH
6.00
7.50
1.70
1.80
1.70
1.80
5WM COILS
FIN HEIGHT
12.00 - 54.00
ROW
DEPTH
8.50
1.78
2.30
4.00
5WD COILS
24
FIN HEIGHT
12.00 - 54.00
ROW
DEPTH
8.50
1.78
2.30
3.75
CONN
SIZE
2-1/2
3.38
2.80
2.80
2.80
2.80
12.00 42.00
3.75
3.06
3.06
3.06
3.06
45.00 54.00
Figure 16. 5M Coils - 1- and 2-row with splayed headers (12 To 54 fin height)
VENT
3.00
AIR
FLOW
RH
LH
AIR
FLOW
0.75
1.50
0.75
1/4 NPT
VENT
RH RETURN
LH SUPPLY
1/4 NPT
DRAIN
W + 3.00
RH SUPPLY
LH RETURN
1.50
1.50
DRAIN
FINNED LENGTH (FL)
6.00
1.50
1.50
A MAX
CD0983632BB-01
TYPE
5MS
5MH
5MQ
5MH
ROW
CONN SIZE
1-1/2
3.00
2.30
2.30
12.00 - 18.00
3.50
2.55
2.55
21.00 - 30.00
2-1/2
3.63
2.80
2.80
33.00 - 42.00
4.00
3.11
3.11
45.00 - 54.00
1-1/2
3.00
2.30
2.30
12.00 - 36.00
3.50
2.55
2.55
39.00 - 54.00
1-1/2
3.00
2.67
2.67
1-1/2
3.00
2.67
2.67
3.50
2.92
2.92
25
0.094
W + 0.188
0.094
1.00
1.00
B MAX
E MAX
1.00
1.125
1.125
1.125
D
D
RETURN
RETURN
RETURN
RETURN
SUPPLY
SUPPLY
SUPPLY
1.125
1.000
1.125
1.125
SUPPLY
2.00
3.50
BB
2 ROW
BB, BS
1 ROW
3.50
3.50
BS
2 ROW
BD
2 ROW
COIL DIMENSIONS
ROW
TYPE
W DIM
5BB
6, 12, 18, 24
2
5BS
5BB
5BD
9, 15, 21
ALL
ALL
ALL
5BS
ALL
2.938
2.938
2.938
2.938
3.438
2.938
2.750
2.750
2.000
2.750
2.000
2.000
1.625
0.875
0.875
1.250
0.500
0.500
2.750
2.750
2.000
2.000
2.000
2.000
26
12, 18, 24
9, 15, 21
0.844
3.094
1.594
0.50
0.50
GENERAL NOTES
1. CONNECTIONS ARE WROUGHT COPPER,
1/2 NPT (EXT.).
.375 DIA
W + 2.00
@ 6.00 C/C
H
1.00
1.00
B MAX
E MAX
1.00
1.125
1.125
1.125
D
D
RETURN
RETURN
RETURN
RETURN
SUPPLY
SUPPLY
SUPPLY
1.125
1.000
1.125
1.125
SUPPLY
2.00
3.50
3.50
BS
2 ROW
BD
2 ROW
3.50
BB
2 ROW
BB, BS
1 ROW
COIL DIMENSIONS
ROW
TYPE
W DIM
5BB
6, 12, 18, 24
2
5BS
5BB
5BD
9, 15, 21
ALL
ALL
ALL
5BS
ALL
2.938
2.938
2.938
2.938
3.438
2.938
2.750
2.750
2.000
2.750
2.000
2.000
2.500
1.750
1.750
2.125
1.375
1.375
2.750
2.750
2.000
2.000
2.000
2.000
12, 18, 24
9, 15, 21
1.000
1.000
2.500
27
A
GENERAL NOTES
1. CONNECTIONS ARE WROUGHT COPPER,
1/2 NPT (EXT.).
2. ALL DIMENSIONS ARE IN INCHES.
W + 0.688
B MAX
4.50
E MAX
2.125
2.750
2.125
2.125
RETURN
RETURN
RETURN
RETURN
SUPPLY
SUPPLY
SUPPLY
D
SUPPLY
2.125
2.750
2.125
BS
2 ROW
BB
2 ROW
BB, BS
1 ROW
2.125
BD
2 ROW
COIL DIMENSIONS
ROW
28
TYPE
W DIM
5BB
6, 12, 18, 24
2
5BS
5BB
5BD
9, 15, 21
ALL
ALL
ALL
5BS
ALL
2.938
2.938
2.938
2.938
3.438
2.938
2.750
2.750
2.000
2.750
2.000
2.000
1.625
0.875
0.875
1.250
0.500
0.500
2.750
2.750
2.000
2.000
2.000
2.000
Tag
Number
CFM
Qty.
Ent. Air
Temp. (F)
Type
Fin Series
Lvg. Air
Temp. (F)
GPM
Rows
Ent. Water
Temp. (F)
Height
(FH)
Lvg. Water
Temp. (F)
Length
(FL)
Face Area
Max. Water
Press. Drop
(Ft.)
Face
Velocity
Max Air
Friction
(In.H20)
29
Notes
30
Warranty
All Daikin equipment is sold pursuant to its standard terms and conditions of sale, including Limited Product
Warranty. Consult your local Daikin representative for warranty details. Refer to Form 933-430285Y. To find your
local Daikin representative, go to www.DaikinApplied.com.
This document contains the most current product information as of this printing. For the most up-to-date
product information, please go to www.DaikinApplied.com.