This easy to use control center is an input device for


the Modular Alarm Platform 5000 solution. Each
control center has a vibrant color 14 cm (5.7 in.) LCD
screen. The durable touch screen gives users access to
system functions through an engaging interface with
intuitive icons. Users directly touch the images on the
screen to arm, disarm, or select other menu options.
Text is shown in language based on the users login.

Durable touch screen - 14 cm (5.7 in.) LCD with


adjustable LED backlight

Graphic interface (16bit vivid color with 320 x 240


pixel resolution) consisting of intuitive icons and
menus

Language option, individually selectable by user

Builtin speaker with adjustable volume

No exposed components when accessing terminals;


all wiring in base with snap-in terminal connections

System overview
Control Center Graphic Interface Main Menu

2 | MAP Control Center (IUI-MAP0001-2)

Screen Name: Identifies the active screen.

Menu buttons: Provides menus of tasks/actions that the user can


choose to perform.

Info button: Provides notification of system events to the user.

Navigation Bar: Icons1 allow the user to navigate through the


interface or obtain context-sensitive Help. Icons are grayed out
when navigation is not available on a given screen.

Refer to IUI-MAP0001-2 User Guide for specific menu


and icon information and instructions.
1

System Application
Up to 32 control centers are supported on the Bosch
Data Bus. Use the ICPMAP0120 MAP Expansion
Enclosure Kit (Power Supply Application) to provide
additional power for remote control centers.

1
5

1.

Bosch Data Bus1

2.

ICPMAP0120 MAP Expansion Enclosure Kit

3.

IPPMAP0005-2 MAP Power Supply 150W

4.

Batteries
Up to two 12 V, 18 Ah batteries connected in series.

5.

IUIMAP0001-2 MAP Control Center

1
For specific bus length data refer to MAP 5000
technical installation guide (ICP-MAP0070).

Functions
Touch Screen
The control center has a resistive touch screen, which
allows the user to use it directly as an input device
without the static nature of physical keys. This
provides a more dynamic and intuitive interaction with
graphics and icons. Thin-film transistor liquid crystal
display (TFTLCD) technology provides excellent image
quality.
The encapsulated electronic assembly protects against
physical damage during handling and installation.
Audible Tones
The control center has a speaker and generates the
following tones:

Accepted Button Press Tone: Acknowledges when a


user makes a selection by pressing an image on the
touch screen.
Invalid Tone: Indicates if the user touches an inactive
button image or an area without a button image.
Entry Delay Tone: Notifies the user to disarm the
system within a specified programmable time period
Exit Delay Tone: Notifies the user that the system is
preparing to arm within a specified programmable
time period.
Intrusion Alarm Tone: Indicates an alarm condition.
Intrusion Supervisory Tone: Indicates a supervisory
point trouble condition.
Intrusion Trouble Tone: Indicates a point trouble
condition.
Chime Tone: Indicates a point activation.
System Trouble Tone: Indicates a system trouble
condition such as a main power failure.

Audio and Visual Controls


The control center has an integrated volume and
brightness control. Because each control center is
individually adjustable, changing the volume or
brightness on one control center does not affect
another control center on the same system.
Languages
For each user, a preferred language is selected when
the user is created. When the user logs in, the
preferred language is used at the control center.
Tamper Input
The control center enclosure has a built-in tamper
switch to detect wall or cover removal.
Certifications and approvals
The control center is designed to comply with the certifications and
standards listed here.
Region

Certification

Europe

EN

EN 50131-1:2006 + A1:2009
EN 50131-3:2009
EN 50131-6:2008

Switzerland

SES

Association of Swiss installers of


security systems
Edition V3/ 01.01.2011-d

France

AFNOR

NF&A2P Grade 3 (when report is


completed from CNPP Lab)
Certificate Number 12xxxxxxxx
(when released by CNPP Cert)
According to NF324-H58

Region

Certification

Germany

VdS-S

S 112016 C MAP 5000

VdS

G111040 C MAP 5000

CE

2004/108/EC EMC Directive (EMC),


2006/95/EC Low-voltage Directive
(LVD)

Europe

3 | MAP Control Center (IUI-MAP0001-2)

Installation/configuration notes

Literature, Installation Guide

Compatibility Information

Screws M3 x 20 mm

Control Panels

Adhesive seal

MAP 5000 Main Panel (ICPMAP5000-2)

Mounting Considerations

Leave space at the bottom of the control center in


order to unlock and open the plastic enclosure easily.
A recommended amount of space is approximately
80 mm (3 in.).
Do not mount the control center in a location
exposed to direct sunlight. Direct sunlight can
interfere with screen visibility.
Do not mount the control center in damp locations.

Terminals and Connectors


The control center has a plastic enclosure. The
terminal blocks and system connectors attached to the
base are accessible by removing the plastic cover.

Technical specifications
Electrical
Input Voltage:

16 VDC to 29 VDC, 28 VDC nominal

Operating Power:

5.0 W, values at 28 VDC


Start-up current: up to 800 mA
In alarm: 175 mA
Idle screen: 100 mA
Dark screen: 60 mA

Mechanical
Dimensions:

156 mm x 171 mm x 39 mm

Weight:

363 g

Touch screen Properties:

14 cm (5.7 in.) TFTLCD; 320 x 240


pixels with 16bit color; white LED
backlight with adjustable brightness
(active and idle backlight); aspect ratio
= 4:3

Housing Material:

Easy-to-clean white textured plastic


housing

Indicators:

Three LEDs.
Green: Power
Yellow: Fault
Red: Alarm

Connections:

4wire Bosch Data Bus connection (data


and power); 2 sets of terminals for daisy
chain in/out wiring

Number of Command
Centers (Maximum):

32

Environmental
The module has 17 terminals.

Operating Temperature:

-10C to +55C (+14F to +131F)

1.

Wall tamper switch

Storage Temperature:

-20C to +60C (-4F to +140F)

2.

Bosch Data Bus connector

Relative Humidity:

3.

Bosch Data Bus connector

5% to 95% (noncondensing) at the


operating and storage temperatures.

4.

Terminals for the relay output. Relay Form A Output


(pin: 1NO, 2COM) currently not enabled

Protective System
Compliant with IEC
60529:

IP 30

5.

Terminals for the addressable inputs currently not enabled

Design type as per EN


50131:

Type B

Environmental Class

Environmental Class II:


EN501305, VdS 2110
For NF&A2P installations, Environmental
Class I according to EN 50130-5.

Use:

Intended for indoor use.

Parts included
Quant.

Component

IUIMAP0001 MAP Control Center

Accessory pack
5 Fixing screws
5 Plugs

Literature, User Guide

4 | MAP Control Center (IUI-MAP0001-2)

Ordering information
MAP Control Center

Graphical color touch screen with adjustable


backlight; builtin speaker with adjustable volume;
user-selectable German, English, French, or Dutch
languages.
Order number IUI-MAP0001-2

Represented by:
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us

Europe, Middle East, Africa:


Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com

Bosch Security Systems 2014 | Data subject to change without notice


1427823243 | en, V19, 21. Nov 2014

Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia

China:
America Latina:
Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
201 Building, No. 333 Fuquan Road
Via Anhanguera, Km 98
North IBP
CEP 13065-900
Changning District, Shanghai
Campinas, Sao Paulo, Brazil
200335 China
Phone: +55 19 2103 2860
Phone +86 21 22181111
Fax: +55 19 2103 2862
Fax: +86 21 22182398
latam.boschsecurity@bosch.com
www.boschsecurity.com.cn
www.boschsecurity.com

You might also like