COPYRIGHTANDCONFIDENTIALTheinformationinthisdocumentisthepropertyofBHARATHEAVYELECTRICALSLTD.

EXCITERAIR COOLER
DATASHEET

Digitally signed
by SANDIP
SARKAR
DN: cn=SANDIP
SARKAR, o=DCPL,
ou=POWER-B,
email=sandipsark
ar@in.dclgroup.c
om, c=IN
Date: 2014.06.09
17:27:24 +05'30'

DEVELOPMENT CONSULTANTS
PRIVATE LIMITED
Reviewed for general conformance with Contract
drawings and specifications.
ACTION :

1 Approved

Disapproved.

2 noted. Forward final

drawing.
Approved except as
noted. Resubmission
required.

For information/reference
only.

Information category with


comments. Resubmission
required.

Approved except as

Approval of Contract documents by the Consultant shall


not relieve the Seller of his responsibility for any errors
and fulfilment of Contract requirements.

OPGCDOCUMENTNO.:BTG-XKC-DSH-E-0208
Rev : 00
CUSTOMER
ODISHAPOWERGENERATIONCORPORATIONLTD.

PROJECT
JOBNO.

RATING

STATUS

CONTRACT

CONSULTANT

IBVALLEYTHERMALPOWERSTATION
2X660MW
DEVELOPMENTCONSULTANTPVT.LTD.KOLKATA
NAME SIGN
BHARATHEAVYELECTRICALS DEPT
CODE
DESN AG
sd
LTD.

Haridwar
CHD
AG
sd

DISTRIBUTION
TO
NO
REV

DATE

ALTD

CHKD

APPD

APPD

SK

sd

DATE
29.04.14
29.04.14
29.04.14

DOCUMENTTITLE:

EXCITERAIRCOOLERDATASHEET

DEPTT
SIGN
DATE

DOCUMENTNO:

HE-10821-16605-D
Page1of2

Rev00

Please furnish thermal & hydraulic calculations showing heat duty, effective surface area and
tube side pressure drop calculations for Exciter Air Cooler.

EXCITER AIR COOLER DATA SHEET


1.01.00

Number of coolers

2x50 %

1.02.00

Type of cooler

Frame type

1.03.00

Material of
Material of the following shall be included :
Tubes
90:10 Cu Ni
- Frames.
Fin
Aluminum / Copper
- Gasket.
Water box
Carbon steel, IS : 2062 Gr.B
or Equivalent
Tube Plate
Carbon Steel / Brass

i)
ii)
iii)
iv)
1.04.00

Total Heat Load

1.05.00

Heat Transfer Area Provided m2

1.06.00

Total Gas Flow

m3/sec

15.5

1.07.00

Inlet Gas Temperature

72.0

1.08.00

Outlet Gas Temperature

44

1.09.00

Tube Side Design Pressure

kg/cm2

10

1.10.00

Total CW flow

m3/hr

110

1.11.00

Design CW Inlet Temp

38

1.12.00

Design CW Outet Temp

42

1.13.00

Pressure Drop across Cooler MWC


On CW Side

1.14.00

Mechanical Design Temp

1.15.00

Tube Side Test Pressure

kg/cm2

KW

500
443

Please confirm that minimum 10%


margin has been provided over
required effective heat transfer
area against selected heat load.

3.3

90
15

Following details shall be included in datasheet :


- Design code & standards.
- Design pressure at shell side.
- Design temperature at both shell & tube sides.
- Operating pressure & temperature at both shell & tube sides.
- Hyd. test duration at tube side.
- Tube plugging margin.
- Corrosion allowance for both shell & tube sides.
- Empty and operating weight of Cooler.
- Painting details (i.e. surface preparation, type of paint, total DFT, color shade etc.).
- LMTD.
- Heat Transfer Co-efficient.
- Tube side velocity.
- Tube OD x thickness.
- LBTP.
- No. of tubes per Cooler.