Power Transformers

Prolec GE offers a complete line of liquid-


filled power transformers with voltages
up to 550kV and ratings up to 550MVA.

Prolec GE transformers are used in a


wide range of utility, commercial and
industrial applications. High-grade
materials, combined with state-of-the-art
technology in our design and
manufacturing systems, are key elements
of a transformer that will deliver years of
high reliability service.

Standard Features
• Meets or exceeds current ANSI®,
IEEE®, CSA and IEC standards.
• Load tap changers.
• Reactive vacuum.
• Resistive.
• Cooling class.
• ONAN.
• ONAF.
• ODAF.
• Cover bushings.
• Tank.
• Lifting lugs.
• Centers of gravity.
• Pulling eyes.
• Radiator header valves.
• Jacking bosses. • Automatic gas preservation system. • Insulation power factor tests
• Accessories. • Rapid pressure rise relay. (class II).
• Pressure relief device. • Under oil. • Induced tests.
• Magnetic liquid level gage. • In gas space. • Partial discharge in microvolts
• Winding temperature indicator. • Lightning arresters. (class II).
• Liquid temperature indicator. • Transformer oil, ASTM type II. • Partial discharge in picocoulombs
• Pressure vacuum gage & bleed • Side mounted bushings ≤ 34.5kV. (class II).
valve. • Conservator oil system. • Dissolved gas in oil analysis above
• Drain valves – globe type. • Buchholz relay for conservators. 10 MVA and all class II.
• Nameplate. • Forced oil cooling equipment. • Accessory equipment and wiring tests.
• Removable radiators. • Provisions only for safety rails. • Tank leak test.
• Manholes in cover (2). • Provisions for lightning arresters. • Optional tests.
• Transformer oil, ASTM type I. • Lightning impulse (class I)
• Dissolved gas in oil analysis
• Sealed tank oil preservation
system. Tests (class I).
• External core ground bushing. • DC resistance tests of all windings. • Temperature rise.
• HV tap changer, de-energized • Polarity of windings & angular • Sound level.
operation. displacement. • Zero phase sequence.
• Ratio. • Front of wave.
• No-load loss & exciting current. • Short circuit.
Optional Features • Load loss & impedance. • Switching surge.
& Accessories • Lightning impulse (class II).
• Low-frequency dielectric tests. ANSI is a registered trademark of American National
• Cooling fans. • Applied voltage tests on all Standards Institute, Incorporated.
• On load tap changer. windings. IEEE is a registered trademark of the Institute of Electrical
• Multi-ratio current transformer. Electronics Engineers, Inc.
Products

Generator Step Up Transformers

• 550 MVA 3 or 200 MVA 1


• 550 kV (1550kV BIL)
• 50 or 60 Hz
• LTC or DETC in HV

Autotransformers

• 650 MVA 3 or 400 MVA 1


• 550 kV (1550kV BIL)
• 50 or 60 Hz
• LTC in HV or LV,
or DETC in HV

Substation and Auxiliary


Transformers

• 550 MVA 3 or 200 MVA 1


• 230 kV (900 kV BIL)
• 50 or 60 Hz
• LTC in HV or LV,
or DETC in HV

Shunt and Neutral Reactors

• 100 MVAr 3 or 75 MVAr 1


• 550 kV (1550 kV BIL)
BIL: Basic Impulse Level
• 50 or 60 Hz LTC: On Load Tap Changer
DETC: De-energized Tap Changer
HV: High Voltage
LV: Low Voltage

Contact Information
Contact your local GE sales representative or visit us at www.prolecge.com

Prolec GE
Phone: 1-800-GEPROLEC Fax: +52 (81) 8030-2500

You might also like