General
Specifications
GS 33J15C15-01EN
n GENERAL
n FUNCTION SPECIFICATIONS
Input Indicator
PVI-DV
Controller Block:
PID
PID Controller
PI-HLD
Sampling PI Controller
Function Block
These are the smallest elements used to perform
control and calculation.
Control Drawing
A control drawing represents the control instruments
responsible for overall control of a small section of the
plant, and typically contains several function blocks and
input/output elements.
For example, a control drawing may be used to
implement cascade control or combustion fuel/air ratio
control.
Input/Output Function
The input/output function is composed of the process
input/output and the software input/output.
The process input/output exchanges data between
external devices. The software input/output is a virtual
element that is inside an FCS.
PID-BSW
ONOFF
ONOFF-E
ONOFF-G
ONOFF-GE
PID-TP
PD-MR
PI-BLEND
Blending PI Controller
PID-STC
Manual Loader
MLD-PVI
MLD-SW
MC-2
MC-2E
MC-3
MC-3E
Ratio Set
PG-L13
BSETU-2
BSETU-3
Velocity Limiter
GS 33J15C15-01EN
Copyright Feb. 2015 (YK)
2nd Edition May 1, 2015 (YK)
<<Contents>> <<Index>>
Signal Selector Block
AS-H/M/L
Signal Selector
SS-H/M/L
Auto-Selector
SS-DUAL
Calculation Block
These function blocks are mainly used to perform
calculation.
Arithmetic Calculation Block:
ADD
Addition
MUL
Multiplication
FOUT
DIV
Division
FFSUM
AVE
Averaging
XCPL
SPLIT
Alarm Block:
ALM-R
*1:
YS Instrument Block:
SQRT
Square Root
EXP
Exponential
LAG
First-Order Lag
INTEG
Integration
LD
Derivative
RAMP
Ramp
LDLAG
Lead/Lag
DLAY
Dead-Time
DLAY-C
Dead-Time Compensation
SLCD
YS Controller
AVE-M
Moving-Average
SLPC
YS Programmable Controller
AVE-C
Cumulative-Average
SLMC
FUNC-VAR
SMST-111
TPCFL
SMST-121
ASTM1
SMRT
ASTM2
SBSD
SLCC
YS Blending Controller
AND
Logical AND
SLBC
YS Batch Controller
OR
Logical OR
STLD
YS Totalizer
NOT
Logical NOT
SRS1-S
SRS1-R
SRS2-S
SRS2-R
WOUT
Wipeout
OND
ON-Delay Timer
OFFD
OFF-Delay Timer
TON
TOFF
GT
GE
FF-DI
FF-CS
FF-PID
FF-RA
Fieldbus Ratio
FF-AO
FF-DO
FF-OS
FF-SC
FF-IT
Fieldbus Integrator
FF-IS
FF-MDI
FF-MDO
FF-MAI
FF-MAO
FF-SUNV
Simple Universal
EQ
Equal Operator
BAND
Bitwise AND
BOR
Bitwise OR
BNOT
Bitwise NOT
General-Purpose Calculation
CALC-C
<<Contents>> <<Index>>
Calculation Auxiliary Block:
SW-33
SI-1E
SW-91
SI-2E
DSW-16
SO-1E
DSW-16C
SO-2E
DSET
Data Set
DSET-PVI
SIO-11E
BDSET-1L
SIO-12E
BDSET-1C
BDSET-2L
SIO-21E
BDSET-2C
SIO-22E
BDA-L
BDA-C
SIO-12PE
ADL
Station Interconnection
SIO-22PE
Timer (*1)
CTS
CTP
ST16
Sequence Table
CI
ST16E
CO
RL
RS
Logic Chart
LC64-E
SFC Block:
_SFCSW
*1:
_SFCPB
Pushbutton SFC
*2:
_SFCAS
Analog SFC
SI-2
SO-1
SO-2
SIO-11
SIO-12
SIO-21
SIO-22
SIO-12P
SIO-22P
Faceplate Block
The faceplate blocks have a human-machine interface
function that allows a single tag to represent several
function blocks.
Analog Faceplate Block:
INDST2
INDST2S
INDST3
PBS5C
PBS10C
<<Contents>> <<Index>>
Unit Instrument, Unit Operation Instrument, and
Operation
The devices and instruments used to control a plant
can be defined as a single unit for operation and control
purposes.
Unit Instrument:
_UTAS
_UTPB
_UTSW
Off-Site Block
The off-site block is a function block that controls
the mixing at off-sites of oil refineries as well as the
shipments.
Off-Site Block:
FSBSET
BLEND
_UTPB-N
_UTSW-N
_UTAS-SN
_UTPB-SN
_UTSW-SN
Software Input/Output
OPSFC
SFC-Type Operation
OPSFCP1
Internal Switch
This is used as a buffer for storing statuses.
OPSFCP2
OPSFCP3
OPSFC4
OPSFC5
UTOP-SN
Operation:
%SW
Common Switch
%GS
Global Switch
Message Output
This function notifies events from one FCS to another
FCS, HIS, or computer.
Annunciator Message:
%AN
Annunciator Message
Sequence Message:
%PR
Print Message
%OG
%VM
%RQ
VPM64
VPM128
Event Massage:
VPM256
VPM512
%CP
VPM64A
%M3
VPM128A
%EV
VPM256A
%RE
VPM512A
<<Contents>> <<Index>>
%Y
Communication Input/Output
The communication input/output is used to access various types of data that are handled by subsystems, such as the
PLC (Programmable Logic Controller).
%W/%X
Communication Input/Output
Fieldbus Input/Output
The Fieldbus input/output is used to access various types of data that are handled by field devices on the Fieldbus.
%Z
Fieldbus Input/Output
<<Contents>> <<Index>>
n APPLICATION CAPACITY
Application capacity represents the number of control functions that can be executed simultaneously. The following
table shows the application capacity of the FCS.
The application capacity of model VP6F1805 Control Function for FCS Simulator is the same as the application
capacity of model VP6F1800.
Table Application Capacity
A2FV50
Item
VP6F1800-V1C01
(Standard)
VP6F1800-V1C02
(Expanded)
VP6F1800-V1C03
(Large)
18000
18000
18000
Tag Names
3500
3500
7000
Process I/O
1760
1760
1760
4096
4096
4096
8000
8000
8000
Common switches
9999
9999
9999
256
256
256
2000
2000
2000
Internal Switches
Global switches
Message Outputs
Annunciator messages
Print messages
2000
2000
2000
1000
1000
1000
200
200
200
1000
1000
1000
Control Functions
Control drawings
200
1 second Trend
Acquisition points
1024
1024
1024
ADL Points
512
512
512
*1:
*2:
*3:
*4:
The number of tag names for elements per FCS indicates the maximum number of contact inputs/outputs (%Z elements),
common switches (%SW elements), global switches (%GS elements) and communication inputs/outputs (%WB/%XB
elements) to which tag names can be assigned. However, you can only assign tag names to each %WB/%XB element up
to 4000.
The number of tag names for function blocks indicates the maximum number of function blocks (%BL elements) and
annunciators (%AN elements) to which tag names can be assigned.
Normal communication inputs/outputs (%WW, %WB) occupy 4000 words, while enhanced communication inputs/outputs
(%XW, %XB) occupy 4000 words, and the total comes to 8000 words.
In the case of C02 (Expanded) type or C03 (Large) type, you can select the number of control drawings from
200/300/400/500. The default number is 200. Selecting 300 or more control drawings may restrict the total number of FCS
in the entire project. Refer to "Integrated Production Control System CENTUM VP System Overview" (GS 33J01A1001EN) for details.
Scan Period
The CPU of the FCS can execute the standard control functions in any of three scan periods. One of the three scan
periods can be set for each function block.
Standard Scan Period: 1 sec.
Medium Speed Scan Period: Specify 200 or 500 ms.
This is mainly used for computation and control of analog data.
Fast Scan Period: Specify 50, 100, 200 or 500 ms.
This is mainly used for sequence control.
The above scan periods does not include the I/O signal conversion time for nodes, and bus transmission time.
GS 33J15C15-01EN
May 1, 2015-00
<<Contents>> <<Index>>
Database
The number of function blocks is defined for each database type. Select the database type at system generation time,
according to your business needs.
The number of function blocks for each database type is shown below:
Table Database
General type
Item
FIO Nodes (*1) (*2)
N-IO Nodes (*2)
N-IO Units (*2)
VP6F1800V1C01
(Standard)
VP6F1800V1C02
(Expanded)
Batch type
VP6F1800V1C03
(Large)
VP6F1800V1C01
(Standard)
VP6F1800V1C02
(Expanded)
VP6F1800V1C03
(Large)
32
32
32
32
32
32
108
108
108
108
108
108
ALF111
64
64
64
64
64
64
32
32
32
32
32
32
64
64
64
64
64
64
500
(500)
(100)
1200
(1200)
(100)
1800
(1500)
(100)
400
(400)
(100)
1000
(1000)
(100)
1500
(1000)
(100)
200
400
700
100
200
400
100
200
400
50
100
150
100
200
300
50
100
150
General-Purpose Calculations
400
500
750
120
250
350
40
100
300
100
200
300
SFC Blocks
Operation Blocks
200
400
500
250
500
700
500
1000
1500
500
1000
1500
Sequence Elements 1
500
700
1100
500
700
1100
Faceplate Blocks
120
200
300
50
100
150
100
200
300
50
100
150
Sequence Elements 2
100
200
300
50
100
150
100
400
600
50
100
150
30
60
80
30
60
80
150
300
400
30
40
60
Unit Instruments
Unit Operation Instruments
Offsite Blocks
Valve Pattern Monitors
System Function Blocks
SEBOL Daemon
SEBOL User Function
Control Recipe Area
Option Area
*1:
*2:
*3:
*4:
*5:
*6:
*7:
*8:
630
630
630
840
840
840
210
210
210
280
280
280
1 MB
1 MB
1 MB
8 MB
8 MB
8 MB
320 KB
320 KB
320 KB
320 KB
320 KB
320 KB
The number of FIO nodes includes the CPU node (A2FV50 itself).
There is no difference in the quantity by the suffix codes of VP6F1800. It is restricted by software.
Please refer to VP6F3100 "Project I/O License" (GS 33J15A10-01EN).
This is the total number of ALR111, ALR121, ALE111, ALP111, ALP121, AGS813, AGP813 and ALF111.
The number of Foundation fieldbus faceplate (FF-FP) blocks is included in regulatory control blocks/calculation blocks.
Note that in the case of C03 (Large) type, the maximum number of faceplate blocks is fewer than regulatory control blocks/
calculation blocks.
The number of PID controller with output loss compensation for wireless (ZWOPID) blocks is included in regulatory control
blocks/calculation blocks.
Standard: Total of 64 input and output signals and 32 rules
Medium size: Total of 96 signals (32-64 inputs and outputs, respectively) and 32 rules
Large size: 64 inputs, 64 outputs, and 32 rules
<<Contents>> <<Index>>
Option Area
In order to use the following functions of the Control Function, option area is required.
Enhanced ON/OFF Controller, Enhanced Motor Control, Enhanced Switch Instrument: 64 KB (*1)
Off-site Block: 80 KB
Valve Pattern Monitor: 90 KB
PID controller with output loss compensation for wireless: 120 KB
*1:
The option area is consumed when one block from any of these types is used.
The total size of the function you want to use must not exceed the size of the option area in the database.
n OPERATING ENVIRONMENT
Hardware Requirements
Model VP6F1800 Control Function for Field Control Station (for A2FV50) operates on the following FCS models:
A2FV50S, A2FV50D
Suffix
Codes
VP6F1800
-V
Software license
Always 1
English version
C01
Standard type
C02
Expanded type
C03
Large type
Description
Model
Suffix
Codes
VP6F1800
-E
Expansion license
Always 1
English version
C12
C13
C23
<<Contents>> <<Index>>
Control Function for FCS Simulator (for A2FV50)
Description
Model
Suffix
Codes
VP6F1805
-V
Software license
Always 1
English version
C01
Standard type
C02
Expanded type
C03
Large type
Description
Model
Suffix
Codes
VP6F1805
-E
Expansion license
Always 1
English version
C12
C13
C23
n ORDERING INFORMATION
Specify model and suffix codes.
n TRADEMARKS